HomeMy WebLinkAboutFile Documents.119 S Spring St.0061.2019 (10).ACBK
Product Data Sheet
GENFLEX™ EZ TPO MEMB RANE
250 West 96th Street, Indianapolis, IN 46260
800-443-4272 | GenFlex.com
Method of Application
1. Substrates must be clean, dry, smooth, and free of
sharp edges, fins, loose or foreign materials, oil, grease,
and other materials that may damage the membrane.
2. All roughened surfaces that can damage the
membrane shall be repaired as specified to offer a
smooth substrate.
3. All surface voids greater than 1/4" (6.3 mm) wide shall
be properly filled with an acceptable fill material.
4. GenFlex EZ TPO membrane is installed as continuous
roofing or waterproofing layer on the roof. Rolls are
overlapped (side laps and end laps) prior to the heat
welding of the seam areas.
5. Install the GenFlex EZ TPO Roofing System in
accordance with current GenFlex EZ TPO
specifications, details and workmanship requirements.
Product Data
45 MIL 60 MIL
Membrane
Thickness 0.045” (1.14 mm) 0.060” (1.52 mm)
Membrane
Weight 0.23 lb/ft2 (1.1 kg/m2) 0.31 lb/ft2 (1.5 kg/m2)
Available Sizes
5’x100’ (1.5x30.5 m)
6’2”x100’ (1.9x30.5 m)
8’x100’ (2.4x30.5 m)
10’x100’ (3.0x30.5 m)
12’4”x100’ (3.8x30.5 m)
5’x100’ (1.5x30.5 m)
6’2”x100’ (1.9x30.5 m)
8’x100’ (2.4x30.5 m)
10’x100’ (3.0x30.5 m)
12’4”x100’ (3.8x30.5 m)
Available Colors
White
Tan
Gray
White
Tan
Gray
LEED® Information
Recycled Content
Post Consumer 0%
Pre Consumer 15%
Manufacturing Location Muscle Shoals, AL
Storage
Store away from sources of punctures and physical
damage.
Assure that structural decking will support the loads
incurred by material when stored on rooftop. The deck load
limitations should be specified by the project designer.
Store away from ignition sources as membrane will burn
when exposed to open flame.
Precautionary Data
Refer to Material Safety Data Sheets (MSDS) for safety
information.
Exercise caution when lifting, moving, transporting, storing
or handling membrane rolls to avoid sources of punctures
and possible physical damage.
Contact your Roof Systems Advisor at 1-800-428-4511 for
specific recommendations regarding chemical or waste
product compatibility with GenFlex EZ TPO Membrane.
Description
GenFlex EZ TPO is a flexible Thermoplastic Polyolefin
(TPO) roofing membrane that is produced with
polyester weft-inserted reinforcement. GenFlex EZ TPO
membrane meets or exceeds all requirements for ASTM
D 6878 Specification. This heat weldable TPO
membrane is available in 45 mil (1.14 mm) and 60 mil
(1.52 mm) thicknesses. This reflective membrane is
suitable for a variety of low-slope applications.
ICC-ES
ESR-2831
CCMC 13348-R
Product Data Sheet
GENFLEX™ EZ TPO MEMB RANE
250 West 96th Street, Indianapolis, IN 46260
800-443-4272 | GenFlex.com
Physical Properties
Meets or exceeds ASTM D 6878 Specification
PROPERTY ASTM STANDARD PERFORMANCE
MINIMUM
Overall Thickness: D 751 0.039" (1 mm)
Coating over
Scrim: D 7635 0.015" (0.38 mm)
Breaking Strength: D 751, Grab Method 220 lbf (979 N)
Elongation of
Reinforcement
Break:
D 751, Grab Method 15%
Tearing Strength: D 751 55 lbf (245 N)
Brittleness Point: D 2137 -40 ºF (-40 ºC)
Ozone Resistance,
No Cracks: D 1149 Pass (No Cracks)
PROPERTY
TYPICAL
PERFORMANCE: 45
MIL
TYPICAL
PERFORMANCE:
60 MIL
Overall Thickness: 0.045" (1.14 mm) ±
10%
0.060" (1.52 mm)
± 10%
Coating Over
Scrim: 0.017" (0.43 mm) 0.021" (0.53 mm)
Breaking Strength: 340 lbf (1,512 N) 390 lbf (1,735 N)
Elongation of
Reinforcement
Break:
25% 25%
Tearing Strength: 120 lbf (534 N) 120 lbf (534 N)
Brittleness Point: Pass Pass
Ozone Resistance,
No Cracks: Pass Pass
Properties After Heat Aging (Retained Values) (ASTM D
573 670 h at 240° F (116° C)
PROPERTY ASTM STANDARD PERFORMANCE
MINIMUM
Breaking Strength: D 751, Grab Method 90% Minimum
Elongation at
Break: D 751, Grab Method 90% Minimum
Tearing Strength: D 751 60% Minimum
Weight of Change: ± 1% Maximum
Linear Dimension
Change:
D 1204, 6 h at 158 °F
(70 °C) ± 1% Maximum
Water Absorption: D 471 ± 3% Maximum
Weather
Resistance, 80 °C
Black Panel, no
cracking, crazing
when wrapped
around a 3"
mandrel and
inspected at 7X
magnification:
G 155 10,800 kJ/m2
Minimum
Puncture
Resistance:
FTM 101C, Method
2031 _____
Dynamic Puncture
Resistance MD: D 5635 _____
Dynamic Puncture
Resistance CD: D 5635 _____
Static Puncture
Resistance: D 5602 _____
Product Data Sheet
GENFLEX™ EZ TPO MEMB RANE
250 West 96th Street, Indianapolis, IN 46260
800-443-4272 | GenFlex.com
PROPERTY
TYPICAL
PERFORMANCE: 45
MIL
TYPICAL
PERFORMANCE:
60 MIL
Breaking Strength: > 90% > 90%
Elongation at
Break: > 90% > 90%
Tearing Strength: > 60% > 60%
Weight of Change: < 1% < 1%
Linear Dimension
Change: < 1% < 1%
Water Absorption: < 3% < 3%
Weather
Resistance, 80 °C
Black Panel, no
cracking, crazing
when wrapped
around a 3"
mandrel and
inspected at 7X
magnification:
> 20,160 kJ/m2 > 20,160 kJ/m2
Puncture
Resistance: 265 (1,180) 300 (1,300)
Dynamic Puncture
Resistance MD: Pass (20 J) Pass (40 J)
Dynamic Puncture
Resistance CD: Pass (35 J) Pass (50 J)
Static Puncture
Resistance: Pass (25 kg) Pass (25 kg)
Radiative Properties
Cool Roof Rating Council
INITIAL/ 3YR WHITE TAN GRAY
Solar
Reflectance 0.79 / 0.68 0.61 / 0.55 0.34 /
Pending
Thermal
Emittance 0.85 / 0.83 0.81 / 0.84 0.89 /
Pending
Solar
Reflectance
Index (SRI)
98 / 81 71 / 63 37 / Pending
Rated Product
ID 0008
Licensed
Manufacturer
ID
0608
Classification Production
Line
Energy Star®
INITIAL / 3 YR
WHITE
TAN
Solar Reflectance 0.79 / 0.78* 0.60 / 0.54
Thermal Emittance 0.85 0.81
*White membrane sample cleaned prior to age test.
LEED®
WHITE TAN GRAY
Solar Reflectance –
ASTM E 903 0.81 0.63 0.37
Thermal Emittance –
ASTM E 408 0.95 0.95 0.95
Solar Reflectance Index
(SRI) – ASTM E 1980 102 77 43
ENERGY STAR is only
valid in the United States