Loading...
HomeMy WebLinkAboutFile Documents.993 Moore Dr.0192.2019 (38).ARBK Page 1 of 4 8/6/2019 P.O. Box 7627, Avon, CO 81620 | P: 970.306.4233 | F: 866.403.3485 | www.activeenergies.com Solar Installation Information Vendor: Active Energies Solar LLC PO Box 7627 Avon, CO 81620 (970-306-4233/info@activeenergies.com) Site: Harland Leeds Residence 933 Moore Drive Aspen, CO 81611 System Layout: Single Panel: 5.42ft tall X 3.25ft wide Panel Arrangement: 12 columns of 7 & 2 columns of 3 + 2 panels, oriented in the portrait position, mounted flush (rail-less) on the east facing garage roof, and 24 panels with RM5 ballast mounted in landscape on central flat roof, and 18 panels with RM5 ballast mounted in landscape on north flat roof HCE electric meter at SW corner of Garage with Production meter and disconnect co-located. Minimum Designed Temperature: -40°F Maximum Ambient Design Temperature: 140°F All AC wiring to be completed by project Colorado licensed master electrician All DC wiring to be overseen by NABCEP certified installer Calculations Inverters & Combo panel (located outside SW corner of External Disconnect & PV Meter Page 2 of 4 8/6/2019 P.O. Box 7627, Avon, CO 81620 | P: 970.306.4233 | F: 866.403.3485 | www.activeenergies.com 48.96kW System Size (STC) • 136 Solaria PowerXT all black solar panels @ 360 watts • 136 SolarEdge P370 Optimizers • 3 SolarEdge SE11400H-US inverters o Inverter 1 (4 strings of 12/12/9/9: 8-16 allowable) o Inverter 2 (3 strings of 15/16/16: 8-16 allowable) o Inverter 3 (3 strings of 15/16/16: 8-16 allowable) • Fixed array tilt angle: 7.18º, 5º • Array azimuth: 90º, 180º (where 180º is south) • Estimated annual power production: 65,429kWh Maximum PV System Voltage: 690.7 Voc = 47.7V/module 47.7V x 1 module = 47.7V No Temperature correction factor 690.7(A) Maximum PV Source Circuit (String) Current: 690.8 (A)(1) Isc = 9.56A 9.56A x 1.25 = 11.95A Maximum PV Output Circuit (Array) Current: 690.8 (A)(2) SE11400H-US inverter limit 30.5A combined string Inverter Output Circuit Current: 690.8 (A)(3) 47.5A @ 240V for SE11400H-US inverter Page 3 of 4 8/6/2019 P.O. Box 7627, Avon, CO 81620 | P: 970.306.4233 | F: 866.403.3485 | www.activeenergies.com Conductor Sizing Pass Thru Box from Optimizers to Inverter (combined strings per inverter): SE11400H-US inverter limit 30.5A combined string 30A x 1.25 = 38.1A #8 THHN-2 Table 310.16 55A (90ºC column, see note 240.4(D)) Conduit fill adjustment Table 310.15 (B)(3)(a) No Conduit Fill Adjustment Inverter to Combiner panel: SE11400H-US inverter Nameplate maximum continuous Output Current: 47.5A @ 240V 47.5A x 125% = 59.4A 210.19 (A)(1) #6 THWN-2 Table 310.16 65A (75°C Column) 60A 2pole breaker in panel No temperature correction factor No conduit fill adjustment Combiner panel to PV Production Meter: 3x 60A breakers in combiner panel (1 per inverter) 1x 200A main Breaker Nameplate maximum continuous Output Current: 59.4A x 3 = 178.2A @ 240V CU 3/0 AWG Table 310.16 200A (75°C Column) No temperature correction factor No conduit fill adjustment Overcurrent Protection Device 200A two pole breaker Per Manufacturer Specification Conductors may be oversized for voltage drop Page 4 of 4 8/6/2019 P.O. Box 7627, Avon, CO 81620 | P: 970.306.4233 | F: 866.403.3485 | www.activeenergies.com DC Grounding Electrode Conductorsolid bare #6 Cu, per NEC 250.66(C) Line Diagram Harland Leeds Residence 993 Moore Drive Aspen, CO 81611 48.96kW Utility Interactive Photovoltaic System Modules: 136 x Solaria PowerXT 360W Voc = 47.7V Isc = 9.56A Optimizers: 136 SolarEdge P370 Inverter 1 (3 strings of 12/12/18: 8-18 allowable) Inverter 2 (3 strings of 15/16/16: 8-18 allowable) Inverter 3 (3 strings of 15/16/16: 8-18 allowable)Inverters: 3x SolarEdge 11400H-US Operating Voltage: 240V Operating Current: 30.5A Max System Voltage: 480V Max Output Current: 15.1A Tilt Angle: 7.18°, 5° Array Azimuth: 90°, 180° Production: 65,429kWh/yr Notes: - See Calculation Sheet for conductor sizing. - All conductors are copper unless otherwise noted. - Inverter listed (UL-1741) to de- energize upon loss of utility voltage per NEC 705.40. - Inverter has integral ground-fault protection per NEC 690.41 - 240V 1 Phase combiner Panel rating of 200A (bus rating 200 amp and 200A Main disconnect) to accommodate 3x 60A (PV) breakers - 1000A 240V 1 Phase Service to accommodate 180A (PV) + 1000A (Main)= 1180A supply (up to 120% of connected power sources from installations per NEC 705.12(B)(2)(1-3)(b) Array 1 12/12/9/9 3 Arrays 136 PowerXT 360w Solar Panels 136 SolarEdge P370 DC Optimizers 42/47/47 modules/optimizers per inverter 25 26 27 33...13 14 15 24... Net Meter On SW side of Garage ~5' 3/4" PVC/ EMT 3x #6 THHN 1 #8 G THWN-2 SolarEdge SE11400H-US Inverter w/ Integrated Disconnect NEMA 3R Max AC Output: 47.5A @ 240V With ARC Fault Protection & Rapid Shutdown compliant – on SW exterior wall of Garage 3 inverters total Production Meter within 10' of net meter ~10' 1 1/4" PVC/ EMT 8 #6 THWN-2 1 #8 G THWN-2 60A Combiner Panel – Co-Located w/ inverters 200A main breaker w/ 200A busbar 3x 60A breakers (1 for each inverter) 60A 60A 6 #10 PV Wire 1# 6G Bare Cu Conductors in Free Air 200A disconnect Array 2 15/16/16 1 2 3 12... 32 33 34 47...16 17 18 31... 1 2 3 15... 32 33 34 47...16 17 18 31... 1 2 3 ... Array 3 15/16/16 15 Inv.1 Inv.2 Inv.3 AC Disco adjacent to net meter ~100' 8/3 FMC w/ G 1000A main breaker w/ 1000A busbar 200A Internal MSP (garage) 6 #10 PV Wire1# 6G Bare Cu Conductors in Free Air 6 #10 PV Wire 1# 6G Bare CuConductors in Free Air ~65' 8/3 FMC w/ G ~5' 3/4" PVC/ EMT 3x #6 THHN 1 #8 G THWN-2 ~5' 3/4" PVC/ EMT 3x #6 THHN 1 #8 G THWN-2 ~65' 8/3 FMC w/ G 34 35 36 42... CT Net meter, exterior, on pedestal About Solaria Established in 2000, The Solaria Corporation has created one of the industry’s most respected IP portfolios, with over 100 patents encompassing materials, processes, applications, products, manufacturing automation and equipment. Headquartered in Fremont, California, Solaria has developed a technology platform that unlocks the potential of solar energy allowing it to be ubiquitous and universally accessed. Achieving up to 20% efficiency, Solaria PowerXT solar modules are one of the highest power modules in the residential solar market. Compared to conventional modules, Solaria PowerXT modules have fewer gaps between the solar cells; this leads to higher power and superior aesthetics. Solaria PowerXT pure black residential modules are manufactured with black backsheet and frames, enhancing a home’s architectural beauty. Developed in California, Solaria’s patented cell cutting and module assembly takes processed solar wafers and turns them into PowerXT solar modules. The process starts by creating a highly reliable PowerXT cell where busbars and ribbon interconnections are eliminated. Solaria then packages the cells into the PowerXT solar module, reducing inactive space between the cells. This process leads to an exceptionally cost effective and efficient solar module. Higher Efficiency, Higher Power Solaria PowerXT modules achieve up to 20% efficiency; conventional modules achieve 15% – 17% efficiency. Solaria PowerXT modules are one of the highest power modules available. Lower System Costs Solaria PowerXT modules produce more power per square meter area. This reduces installation costs due to fewer balance of system components. Improved Shading Tolerance Sub-strings are interconnected in parallel, within each of the four module quadrants, which dramatically lowers the shading losses and boosts energy yield. Improved Aesthetics Compared to conventional modules, Solaria PowerXT modules have a more uniform appearance and superior aesthetics. Durability and Reliability Solder-less cell interconnections are highly reliable and designed to far exceed the industry leading 25 year warranty. The Solaria Corporation 1700 Broadway, Oakland, CA 94612 P: (510) 270-2500 www.solaria.com Copyright © 2019 The Solaria Corporation Product specifications are subject to change without notice. Rev 1K 02-14-2019 Solaria PowerXT®-360R-PD | Solaria PowerXT®-355R-BD Solaria PowerXT® | Residential About Solaria Established in 2000, The Solaria Corporation has created one of the industry’s most respected IP portfolios, with over 100 patents encompassing materials, processes, applications, products, manufacturing automation and equipment. Headquartered in Oakland, CA, Solaria has developed a technology platform that unlocks the potential of solar energy. The Solaria Corporation 1700 Broadway, Oakland, CA 94612 P: (510) 270-2500 www.solaria.com Copyright © 2019 The Solaria Corporation Product specifications are subject to change without notice. Rev 1K 02-14-2019 Solaria PowerXT®-360R-PDSolaria PowerXT®-355R-BD Performance at STC (1000W/m2, 25° C, AM 1.5) Solaria PowerXT-350R-BD 355R-BD 355R-PD 360R-PD Max Power (Pmax)[W]350 355 355 360 Efficiency [%]19.4 19.6 19.6 19.9 Open Circuit Voltage (Voc)[V]47.4 47.7 47.4 47.7 Short Circuit Current (Isc)[A]9.44 9.48 9.53 9.56 Max Power Voltage (Vmp)[V]39.2 39.5 39.1 39.5 Max Power Current (Imp)[A]8.94 8.99 9.09 9.13 Power Tolerance [%]-0/+3 -0/+3 -0/+3 -0/+3 Performance at NOCT (800W/m2, 20°C Amb, Wind 1 m/s, AM 1.5) Max Power (Pmax)[W]258 261 261 265 Open Circuit Voltage (Voc)[V]44.6 44.8 44.6 44.8 Short Circuit Current (Isc)[A]7.61 7.64 7.68 7.71 Max Power Voltage (Vmp)[V]36.1 36.3 36.0 36.3 Max Power Current (Imp)[A]7.15 7.19 7.27 7.30 Temperature Characteristics NOCT [ºC]45 +/-2 Temp. Coeff. of Pmax [% / ºC]-0.39 Temp. Coeff. of Voc [% / ºC]-0.29 Temp. Coeff. of Isc [% / ºC]0.04 Design Parameters Operating temperature [ºC]-40 to +85 Max System Voltage [V]1000 Max Fuse Rating [A]15 Bypass Diodes [#]4 Mechanical Characteristics Cell Type Monocrystalline Silicon Dimensions (L x W x H)1621mm x 1116mm x 40mm Weight 21 kg / 46 lbs Glass Type / Thickness AR Coated, Tempered / 3.2mm Frame Type Black Anodized Aluminum Cable Type / Length 12 AWG PV Wire (UL) / 1000mm Connector Type MC4 compatible Junction Box IP67 / 4 diodes Front Load (UL 1703)5400 Pa / 113 psf* Rear Load (UL 1703)2400 Pa / 50 psf* * Refer to Solaria Installation Manual for details Certifications / Warranty Certifications UL 1703/IEC 61215/IEC 61730/CEC CAN/CSA-C22.2 Fire Type (UL 1703)1 Power & Product Warranty 25 years* * Warranty details at www.solaria.com Packaging Stacking Method Horizontal / Palletized Pcs / Pallet 25 Pallet Dims 1668 x 1150 x 1230 mm Pallet Weight 590 kg / 1300 lbs Pallets / 40-ft Container 28 Pcs / 40-ft Container 700 '" 10 9 8 7 6 5 4 3 2 0 0 5 10 15 20 25VOLTAGE (V)CURRENT (A)30 35 40 45 50 1 1000 W/m2 800 W/m2 600 W/m2 400 W/m2 200 W/m2 IV Curves vs. Irradiance (350W Module) Comprehensive 25-Year Warranty Years 25-year workmanship and performance from Solaria Typical Tier 1 industry warranty 100% 90% 80% 98% 5 10 251520 86% 81%Workmanship Limit POWER OPTIMIZERSolarEdge Power Optimizer Module Add-On For North America P300 / P320 / P370 / P400 / P405 Up to 25% more energy Superior efficiency (99.5%) Mitigates all types of module mismatch losses, from manufacturing tolerance to partial shading Flexible system design for maximum space utilization Fast installation with a single bolt Next generation maintenance with module-level monitoring Module-level voltage shutdown for installer and firefighter safety PV power optimization at the module-level www.solaredge.usUSA - CANADA - GERMANY - ITALY - FRANCE - JAPAN - CHINA - AUSTRALIA - THE NETHERLANDS - UK - ISRAEL - TURKEY - SOUTH AFRICA - BULGARIA - INDIA © SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 03/2017 V.02. Subject to change without notice. (2) For detailed string sizing information refer to: http://www.solaredge.com/sites/default/files/string_sizing_na.pdf.(3) It is not allowed to mix P405 with P300/P370/P400/P600/P700 in one string. P300 (for 60-cell mod- ules) P320 (for high-power 60-cell modules) P370 (for higher-power 60 and 72-cell modules) P400 (for 72 & 96-cell modules) P405 (for thin film modules) INPUT Rated Input DC Power(1)300 320 370 400 405 W Absolute Maximum Input Voltage (Voc at lowest temperature) 48 60 80 125 Vdc MPPT Operating Range 8 - 48 8 - 60 8 - 80 12.5 - 105 Vdc Maximum Short Circuit Current (Isc) 10 11 10.1 Adc Maximum DC Input Current 12.5 13.75 12.63 Adc Maximum Efficiency 99.5 % Weighted Efficiency 98.8 % Overvoltage Category II OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Current 15 Adc Maximum Output Voltage 60 85 Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output Voltage per Power Optimizer 1 Vdc STANDARD COMPLIANCE EMC FCC Part15 Class B, IEC61000-6-2, IEC61000-6-3 Safety IEC62109-1 (class II safety), UL1741 RoHS Yes INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Compatible inverters All SolarEdge Single Phase and Three Phase inverters Dimensions (W x L x H)128 x 152 x 27.5 / 5 x 5.97 x 1.08 128 x 152 x 35 / 5 x 5.97 x 1.37 128 x 152 x 50 / 5 x 5.97 x 1.96 mm / in Weight (including cables)630 / 1.4 750 / 1.7 845 / 1.9 gr / lb Input Connector MC4 Compatible MC4 / Amphenol AH4 MC4 Compatible Output Wire Type / Connector Double Insulated; MC4 Compatible Double Insulated; MC4 / Amphenol AH4 Double Insulated; MC4 Compatible Output Wire Length 0.95 / 3.0 1.2 / 3.9 m / ft Operating Temperature Range -40 - +85 / -40 - +185 ˚C / ˚F Protection Rating IP68 / NEMA6P Relative Humidity 0 - 100 % (1) Rated STC power of the module. Module of up to +5% power tolerance allowed. SolarEdge Power Optimizer Module Add-On for North America P300 / P320 / P370 / P400 / P405 PV SYSTEM DESIGN USING A SOLAREDGE INVERTER(2)(3) SINGLE PHASE HD-WAVE SINGLE PHASE THREE PHASE 208V THREE PHASE 480V Minimum String Length (Power Optimizers) 8 10 18 Maximum String Length (Power Optimizers)25 25 50 Maximum Power per String 5700 (6000 with SE7600H-US)5250 6000 12750 W Parallel Strings of Different Lengths or Orientations Yes INVERTERSwww.solaredge.us 12-25 Single Phase Inverter with HD-Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US / SE7600H-US / SE10000H-US / SE11400H-US Optimized installation with HD-Wave technology Specifically designed to work with power optimizers Record-breaking efficiency Fixed voltage inverter for longer strings Integrated arc fault protection and rapid shutdown for NEC 2014 and 2017, per article 690.11 and 690.12 UL1741 SA certified, for CPUC Rule 21 grid compliance Extremely small High reliability without any electrolytic capacitors Built-in module-level monitoring Outdoor and indoor installation Optional: Revenue grade data, ANSI C12.20 Class 0.5 (0.5% accuracy) SE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US OUTPUT  Rated AC Power Output 3000 3800 @ 240V 3300 @ 208V 5000 6000 @ 240V 5000 @ 208V 7600 10000 11400 VA Max. AC Power Output 3000 3800 @ 240V 3300 @ 208V 5000 6000 @ 240V 5000 @ 208V 7600 10000 11400 VA AC Output Voltage Min.-Nom.-Max. (183 - 208 - 229)-3 -3 ---Vac AC Output Voltage Min.-Nom.-Max. (211 - 240 - 264) 3 3 3 3 3 3 3 Vac AC Frequency (Nominal)59.3 - 60 - 60.5(1)Hz Maximum Continuous Output Current 208V -16 -24 ---A Maximum Continuous Output Current @240V 12.5 16 21 25 32 42 47.5 A GFDI Threshold 1 A Utility Monitoring, Islanding Protection, C o u nt r y C o nfi g u ra b l e T h re s h o l d s Yes INPUT  Maximum DC Power @240V 4650 5900 7750 9300 11800 15500 17650 W Maximum DC Power @208V -5100 -7750 --- Transformer-less, Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vdc Maximum Input Current 208V -9 -13.5 --- Maximum Input Current @240V 8.5 10.5 13.5 16.5 20 27 30.5 Adc Max. Input Short Circuit Current 45 Adc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600k Sensitivity Maximum Inverter Efficiency 99 99.2 % CEC Weighted Efficiency 99 % Nighttime Power Consumption < 2.5 W ADDITIONAL FEATURES Supported Communication Interfaces RS485, Ethernet, ZigBee (optional), Cellular (optional) Revenue Grade Data, ANSI C12.20 Optional(2) Rapid Shutdown - NEC 2014 and 2017 690.12 Automatic Rapid Shutdown upon AC Grid Disconnect STANDARD COMPLIANCE Safety UL1741, UL1741 SA, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07 Grid Connection Standards IEEE1547, Rule 21, Rule 14 (HI) Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS  AC Output Conduit Size / AWG Range 3/4” minimum / 14-6 AWG 3/4” minimum /14-4 AWG DC Input Conduit Size / # of Strings / AWG Range 3/4” minimum / 1-2 strings / 14-6 AWG 3/4” minimum / 1-3 strings / 14-6 AWG Dimensions with Safety Switch (HxWxD) 17.7 x 14.6 x 6.8 / 450 x 370 x 174 21.3 x 14.6 x 7.3 / 540 x 370 x 185 in / mm Weight with Safety Switch 22 / 10 25.1 / 11.4 26.2 / 11.9 38.8 / 17.6 lb / kg Noise < 25 <50 dBA Cooling Natural Convection Natural convection Operating Temperature Range -13 to +140 / -25 to +60(3) (-40˚F / -40˚C option)(4)˚F / ˚C Protection Rating NEMA 3R (Inverter with Safety Switch) Single Phase Inverter with HD-Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US / SE10000H-US / SE11400H-US (1) For other regional settings please contact SolarEdge support (2) Revenue grade inverter P/N: SExxxxH-US000NNC2(3) For power de-rating information refer to: https://www.solaredge.com/sites/default/files/se-temperature-derating-note-na.pdf(4) -40 version P/N: SExxxxH-US000NNU4 © SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 07/2018/V01/ENG NAM. Subject to change without notice.