Loading...
HomeMy WebLinkAboutFile Documents.117 S Spring St.0025-2020-BCOM (2)NPE Series Tankless Water Heaters Specification SheetPremium Condensing Tankless Gas Water Heater Optional accessories (see below) Direct Vent (Indoor) 2” Intake Cap 2" Coupling Mobile/Manufactured Homes Non-Direct Vent (Indoor) Non-Direct Vent (Outdoor) 2" Pipe Diagnostics Information Reset Up Down Power ON/OFF NPE-150 NPE-180 NPE-210 NPE-240 NPE-150 NPE-180 NPE-210 NPE-240 Dual Primary and Secondary Stainless Steel Heat Exchangers Technology Buffer Tank Recirculation Pump Wi-Fi Common Vent Compatible Freeze Protection Uniform Energy Factor Ratings NPE-180A/210A/240A NPE-150S NPE-180S/210S/240S CSA, NSF 5, AHRI, AB1953 ,SCAQMD (Rule 1146.2 Type 1 - Complies with 14 ng/J or 20 ppm NOx @ 3% O2) Natural Gas (NG)Propane (LPG)*** Built-in Control Panel ANSI Z21.10.3 - CSA 4.3-2015 2” PVC vent up to 60 ft**150 ft** using 3” PVC vent 1/2” gas pipe up to a length of 24 ft* Remote Controller NR-20DU (30009757A) Plumb Easy Valve Set (3/4”) (30009323A - Lead Free) (30012581A - for Pipe Cover) Ready-Link Communication Cable (GXXX000546) Outdoor Vent Kit Condensate Neutralizer (GXXX001322 - Single Unit) (GXXX001324 - Up to 6 Units) (GXXX001325 - Up to 16 Units) Outdoor Vent Cap Built-In Control Panel with Diagnostics Sleek Design - Compatible with 2” PVC Vent and 1/2” Gas Pipe TM Indoor and Outdoor Venting Options Ready-Link Cascade Compatible Temperature Options Residential Commercial SleekDesign Compatible ith INTELLIGENT Preheating (optional for “S” models) 3” Vent Termination Caps and Wall Flanges (GXXX3873B) Job Name: _____________________________________________ Location: ______________________________________________ Engineer: _____________________________________________ Wholesaler: __________________________________________ Contractor: ___________________________________________ Model No.: _____________________________________________ Submitted to: _________________________________________ (30010604A) 15-Year 5-Year 8-Year 5-Year (**** see Navien Limited Warranty) External Pump Wire (GXXX001319)04/28/2020 cosgwamouwaha(s)shab cvNPESsmos asmaufacubyNav Ic.cbyoh asoofNSIsaaZ21.10.3/S4.3.Waha (s)shahava15-yamHaExchagwaay LmWaay.U(s)sha bsgobuaua .Waha(s)shahava omaowacaacyof________GPM/GPH________°sw hauof_____________BTU/h.Wa ha(s)shabvPV/vaa sacooxc60’(oquva)wh .Waha(s)safo150PSIwog ssua300PSIsssu.Gassuy ssushab3.5o10.5Wfoaua gasa.0o13.0Wfooa.U(s)shahavascasuasa ssshaxchagscomxbu 3/4gascoco3/4bass /ouwacocoswahog of1.0 gaofohNmo aacosacoco.Th Nmowghsbs ahN240 mowgh2bs.U(s)shacu faussuchasaajusmfo hghvaomauocoua mauoosfom120°1°vas125-140°5°vas 150-10°10°vas a12°.moshacua accuaouma0.5g aobuffa.Thwaha(s)sha bcoobyaaccuboa hamooshaouma uswhsahmsosssg acoogowaosomau whafuaocoos oomaahmaombusofcc y.U(s)shacusafyfaussuchas amssosysmovha vovcfzoco afamoooaoco.Musys m(casca)acaoshaqu2 o16usshasabycocgh ususgcaboyco cos(Ray-L). Thwaa(s)xcshgyfccyqu msofSHRE0.1as sbySQMu1146 .2foLowNOxhacomswh 14g/Jo20mNOxqums@3%O2 Dimensions Specifications 27.4" (695mm)28.8" (731mm) 3" (77mm)6.7" (170mm)4.5" (115mm)0.4" (10mm)1.5" (38mm)14.3" (364mm)2.6" (67mm)A B 13.2" (336mm) 2.3" (60mm) 3.0" (77mm) 8.3" (212mm) 17.3" (440mm)2.4" (61mm)2.4" (61mm)C F D G E NPE Series Tankless Water Heaters Specification SheetPremium Condensing Tankless Gas Water Heater A B C F D G E Air Intake Φ 2" Exhaust Gas vent Φ 2" Hot Water Outlet Φ 3/4" Recirculation Inlet* Φ 3/4" Cold Water Inlet Φ 3/4" Gas Inlet Φ 3/4" Condensate Outlet Φ 1/2" Connection Size Connection Size Navien, Inc. 20 Goodyear, Irvine, CA 92618 Ph: (949)420-0420 Fax: (949)420-0430 www.Navien.com Rev. 11/16 * “A” models only Item NPE-150S NPE-180A NPE-180S NPE-210A NPE-210S NPE-240A NPE-240S Heat Capacity (Input) Natural Gas 18,000- 120,000 BTU/H 15,000-150,000 BTU/H 19,900-180,000 BTU/H 19,900-199,900 BTU/H Propane Gas 15,000-150,000 BTU/H 19,900-180,000 BTU/H 19,900-199,900 BTU/H Efficiency Ratings UEF (for NG & LP)0.96 0.96 0.97 0.96 0.97 0.96 0.97 EF (Canada) (for NG & LP)0.97 0.97 0.99 0.97 0.99 0.97 0.99 Flow Rate (DHW) 35°F(19°C) Temp Rise 6.8 GPM (26 L/m) 8.4 GPM (32 L/m) 10.1 GPM (38 L/m) 11.2 GPM (42 L/m) 45°F(25°C) Temp Rise 5.3 GPM (20 L/m)6.5 GPM (25 L/m) 7.8 GPM (30 L/m) 8.7 GPM (33 L/m) 67°F(36°C) Temp Rise 3.2 GPM (12 L/m) 4.3 GPM (16 L/m) 4.2 GPM (16 L/m) Dimensions 17.3"(W) x 27.4"(H) x 13.2"(D) Weight 55 lbs (25kg) 75 lbs (34kg) 67 lbs (30kg) 82 lbs (37 kg) 75 lbs (34kg) 82 lbs (37 kg) 75 lbs (34kg) Installation Type Indoor or Outdoor Wall-Hung Venting Type Forced Draft Direct Vent Ignition Electronic Ignition Water Pressure 15-150 PSI Natural Gas Supply Pressure (from source)3.5 in WC-10.5 in WC Propane Gas Supply Pressure (from source)8 in WC-13in WC Natural Gas Manifold Pressure (min-max) -0.04 in WC - -0.38 in WC -0.04 in WC - -0.84 in WC -0.05 in WC - -0.36 in WC -0.05 in WC - -0.58 in WC Propane Gas Manifold Pressure (min-max) -0.04 in WC - -0.42 in WC -0.05 in WC - -0.50 in WC -0.10 in WC - -0.66 in WC -0.10 in WC - -0.78 in WC Minimum Flow Rate 0.5 GPM (1.9 L/m), < 0.01 GPM (0.04 L/m) option for “A” models* Connection Sizes Cold Water Inlet 3/4 in NPT Hot Water Outlet 3/4 in NPT Gas Inlet 3/4 in NPT Power Supply Main Supply 120V AC, 60Hz Maximum Power Consumption 200W (max 2A), 350W (max 4A) with external pump connected Materials Casing Cold Rolled Carbon Steel Heat Exchangers Primary Heat Exchanger: Stainless Steel Secondary Heat Exchanger: Stainless Steel Venting Exhaust 2" or 3" PVC, CPVC, Polypropylene 2" or 3" Special Gas Vent Type BH (Class II, A/B/C) Intake 2" or 3" PVC, CPVC, Polypropylene 2" or 3" Special Gas Vent Type BH (Class II, A/B/C) Vent Clearances 0" to combustibles Safety Devices Flame Rod, APS, Ignition Operation Detector, Water Temperature High Limit Switch, Exhaust Temperature High Limit Sensor, Power Surge Fuse 5.0 GPM (19 L/m) 5.2 GPM (20 L/m) 5.6 GPM (21 L/m) 5.7 GPM (22 L/m) * Available for “A” models configured in an optional ComfortFlow recirculation mode. Additional energy use will occur when using recirculation. 04/28/2020