Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
File Documents.215 S Monarch St.0005-2020-BCOM (27)
EMERGENCY LHQM-LED Catalog Number Notes Type FEATURES & SPECIFICATIONS INTENDED USE — Suitable for applications requiring both exit sign and unit equipment. Attractive, 8" tall, streamlined design is great for above-the-door applications and other tight fits. Optional high-output version with remote lamps are ideal for emergency egress lighting. Certain airborne contaminants can diminish integrity of acrylic and/or polycarbonate. Click here for Acrylic- Polycarbonate Compatibility table for suitable uses. CONSTRUCTION — Engineering-grade thermoplastic housing is impact-resistant, scratch-resistant and corrosion-proof. UL94V-O flame rating. UV-stable resin resists discoloration from natural and man-made light sources. Rugged unibody housing snaps together with no additional fasteners. Faceplate and back cover are inter- changeable on housing. Positive snap-fit tabs hold faceplate securely, yet are easily removable for lamp compartment access. Universal, directional chevron inserts are easily removed and reinserted. Uniform graphics illumination without shadows or hot spots. Letters are 6" high with 3/4" stroke, with 100 ft. viewing distance rating based upon UL924 standard. LEDs mounted on primary circuit boards for sign illumination. Low-energy LED lamp in sign operates in normal (AC input) and emergency (DC input) modes. Low-profile, integrated test switch/pilot light. Easily viewed bright red status indicator. Unique track-and-swivel arrangement permits full range of direction of lamp head adjustment. Universal J-box mounting pattern. Tool-less access for maintenance. Conduit entry position on top of unit. U.S. Patent No. 6,848,798; 6,499,866; 6,142,648; 5,797,673; D379,373; 5,526,251; D484,272; D473,672; 5,611,163; 5,646,502. OPTICS — Twin LED lamp heads operate in emergency (DC input) mode with 12 series-parallel white LEDs in each head. Provides redundant light sources to ensure emergency lighting performance. The typical life of the exit LED lamp is 10 years. ELECTRICAL — Dual-voltage input capability (120/277V). Edge connector on printed circuit board ensures long-term durability. Current-limiting charger maximizes battery life and minimizes energy consumption. Provides low operating costs. Short-circuit protection — current-limiting charger circuitry protects printed circuit board from shorts. Thermal compensation adjusts charger output to provide optimum charge voltage relative to ambient temperature. Regulated charge voltage maintains constant-charge voltage over a wide range of line voltages. Prevents over/ undercharging that shortens battery life and reduces capacity. Filtered charger input minimizes charge voltage ripple and extends battery life. AC/LVD reset allows battery connection before AC power is applied and prevents battery damage from deep discharge. Single multi-color LED indicator to display two-state charging, test activation and three-state diagnostic test. Test switch provides manual activation of 30-second diagnostic testing for on-demand visual inspection. Self-diagnostic testing for 30 seconds every 30 days, 30 minutes at 180-day interval, and 90 minutes annually. Diagnostic evaluation of LED light source, AC-to-DC transfer, charging and battery condition. Battery: Sealed, maintenance-free nickel-cadmium battery delivers 90-minute capacity to emergency lamps. Two-state contstant-current charge maximizes battery life and automatically recharges after battery discharge. Low-voltage disconnect prevents excessively deep discharge that can permanently damage the bat- tery. Optional high-output battery to power both local and optional LED remote lamp heads simultaneously. INSTALLATION — Top, end or back mounting. Housing snaps to canopy with positive-locking tabs. Cam locking pin secures housing to canopy. Easily removed mounting knockouts. Conduit entry knockout for 1/2" flexible conduit. J-box pattern on back panel. LISTINGS — UL damp location listed standard 50°-104°F (10°-40°C). Meets UL 924, NFPA 101 (current Life Safety Code), NEC and OSHA illumination standards. WARRANTY — 5-year limited warranty. (Battery is prorated). Complete warranty terms located at www.AcuityBrands.com/CustomerResources/Terms_and_Conditions.aspx. Note: Actual performance may differ as a result of end-user environment and application. All values are design or typical values, measured under laboratory conditions at 25 °C. Specifications subject to change without notice. Thermoplastic Exits LHQM LED LED Lamp Head Nickel-Cadmium Battery LHQM LED Family Lamp type Housing color Letter color Options LHQM Stencil face, single face plate with extra face plate LED Two 1.5W/9.6V white LED (blank)White B Black R Red G Green HO High-output Ni-cad battery NOM Meets Mexican standards1 HO R0 High-output option, less lamp heads NOM SALIDA Salida signage (non-UL)2 SD Self-diagnostics ORDERING INFORMATION Lead times will vary depending on options selected. Consult with your sales representative. Example: LHQM LED G Notes 1 Available in black or white. Consult factory for options. 2 Only available in white. NOM standard. 3 Only compatible with self-diagnostic option. (ex: HO SD) 4 Also available in black. Add "B" after ELA to order black finish. Example: ELA B Q L0309. 5 Only compatible with HO option . See spec sheet ELA-Q-LED. 6 See spec sheet ELA-WG. 7 See spec sheet ELA-Stemkits. 8 See spec sheet ERE. 9 Not available with SD. Only compatible with HO option. Accessories: Order as separate catalog number. ELA Q L0309 SD Single, LED indoor remote head, white, self-diagnostics 3,4,5 ELA T Q L0309 SD Twin, LED indoor remote head, white, self-diagnostics 3,4,5 ELA QWP L0309 SD Single, LED weather-proof remote head, gray, self-diagnostics 3,4,5 ELA T QWP L0309 SD Twin, LED weather-proof remote head, gray, self-diagnostics 3,4,5 ELA Q L0309 Single, LED indoor remote head, white4,5 ELA T Q L0309 Twin, LED indoor remote head, white4,5 ELA QWP L0309 Single, LED weather-proof remote head, gray4,5 ELA T QWP L0309 Twin, LED weather-proof remote head, gray4,5 ELA WG3 Wireguard, 30” W x 13-1/2” H x 6” D6 ELA WG2M Wireguard, 21-1/4” W x 15” H x 12” D6 ELA LQMUS12 12” white stem kit7 ERE W SGL SQ M12 Single, LED indoor remote head, square, ivory white, .75W, 3.6V-12V voltage sensing8,9 ERE W T SQ M12 Twin, LED indoor remote head, square, ivory white, 1.5W, 3.6V-12V voltage sensing8,9 ERE GY SGL WP SQ M12 Single, LED weather-proof remote head, square, gray, 1W, 3.6V-12V voltage sensing8,9 ERE GY T WP SQ M12 Twin, LED weather-proof remote head, square, gray, 2W, 3.6V-12V voltage sensing8,9 HO R0 Looking for Contractor Select readily available configurations? Click here to visit Contractor Select™ spec sheet or go to www.contractorselect.com LHQM-LED EMERGENCY: One Lithonia Way Conyers, GA 30012 Phone: 800-705-SERV (7378) www.lithonia.com techsupport-emergency@acuitybrands.com © 2012-2019 Acuity Brands Lighting, Inc. All rights reserved. Rev. 09/04/19 LHQM LED QUANTUM® Exit/Unit Combo MOUNTING All dimensions are inches (centimeters). Shipping weight: 3.6 lbs. (1.6 kgs.). Top End 19-1/4(48.9) 12(30.5) 8(20.3) Test switch/ pilot light 4-3/4(11.1) 9(22.9) 2-1/4(5.7) 5-5/8(14.3) 1/2” flexible conduit entry knockout 6 12 (15.2) (30.5) 4(10.2) 8(20.3) Universal knockout pattern for various standard j-boxes Backplate Face EXTENDED RUN-TIME FOR HIGH-OUTPUT EXITS Product Run time LHQM LED HO (no remotes) 3.8 hours LHQM LED HO R0 (no remotes) 7.5 hours LAMP PHOTOMETRICS QUANTUM LED SERIES – SINGLE COVERAGE 3W Total White LEDs Using a single unit at a typical 7.5’ mounting height delivers an average illuminance of 1.0 FC over a distance of 24’ on a 3’ path of egress and 18’ on a 6’ path of egress. 24' 3' 1 FC average 18' 1 FC average 6' 1 FC average 25' 3'6' 20' 1 FC average Example of single LHQM LED exit illuminating a 3' path of egress Example of single LHQM LED exit illuminating a 6' path of egress Example of multiple LHQM LED exits illuminating a 3' path of egress Example of multiple LHQM LED exits illuminating a 6' path of egress SPECIFICATIONS 1 Based on continuous operation. 2 At 77°F (25°C). 3 All life safety equipment, including emergency lighting path of egress, must be maintained, serviced and tested in accordance with all National Fire Protection Association and local codes. Failure to perform the required maintenance, service or testing could jeopardize the safety of occupants and will void all warranties. 4 Optimum ambient temperature range where unit will provide capacity for 90 minutes. Higher and lower temperatures affect life and capacity. 5. Battery life is negatively impacted by many variables including temperature, charging rates, number of cycles and deep discharges due to long periods of time without AC power. Electrical Primary Circuit Typical LED life1 Supply voltage Max amps Max watts Red and green LED 10 years 120 .05 4.3 277 .03 4.3 Ni-Cad Voltage Typical Shelf life2 Typical life2 Maintenance3 Temperature range4 9.6 3 years 7-9 years none 50-104°F (10-40°C) BATTERY Remote Output Capacity Standard unit Combo Combo/high-output battery(HO) Combo/high-output (HO) and no heads (RO) NA NA 3W 6W QUANTUM LED SERIES – MULTIPLE COVERAGE 3W Total White LEDs Using multiple units at a typical 7.5’ mounting height delivers 25’ center-to-center spacing on a 3’ path of egress and 20’ center-to-center spacing on a 6’ path of egress.