Loading...
HomeMy WebLinkAboutFile Documents.345 Park Ave.0081-2021-BRES (6)Job: Project No.: Date: Location: Present: ODDO ENGINEERING, INC. FIELD REPORT #1 351 Park Ave, Aspen, Co 2020-46 August 27, 2020 Job site Judd Clarence; Giant Properties Robert Oddo; Oddo Engineering Field Observation Notes: oddo I 1.It is acceptable to reuse the existing deck columns if no remaining decay is in place top or bottom. Once the decay is removed on top it is acceptable to bear the new 6x 12 timber beams and fasten with ½" dia diagonal lag screws, 4" min embedment. 713 Cooper Avenue ♦ Suite 200 ♦ Glenwood Springs, CO 8160 I (970)945-1006 ♦ Fax (970) 945-2966 ♦ E-Mail bob@oddogws.com 10/15/2020 10/16/202006/04/2021 10/16/202006/04/2021