Loading...
HomeMy WebLinkAboutFile Documents.800 S Mill St.0008-2019-BRES (2)0008-2019-BRES_BuildingComments_1 File Name: Fifth Ave Unit 102 C PLANS.pdf Author: bonniem Subject: 3/16" Scale Color: Page Label: A-2 PROPOSED LEVEL 2 FLOOR PLAN Page Index: 4 Lock: Unlocked Checkmark: Unchecked Date: 9/9/2019 1:53:22 PM Creation Date: 9/9/2019 1:53:22 PM X: 7.0211 in Y: 2.2428 in Document Width: 1.7983 in Document Height: 1.7717 in Length: 28.46 ft' in" Unit: sf Wall Area: 228 sf Depth: 8.00 ft Measurement: 46 sf Sequence: Capture: No 46 sf bonniem (3) File Name: Fifth Ave Unit 102 C PLANS.pdf Author: bonniem Subject: PlanCheck Color: Page Label: A-2 PROPOSED LEVEL 2 FLOOR PLAN Page Index: 4 Lock: Unlocked Checkmark: Unchecked Date: 9/9/2019 2:17:56 PM Creation Date: 9/9/2019 2:02:38 PM X: 0.8046 in Y: 0.7002 in Document Width: 8.4201 in Document Height: 9.4222 in Length: Unit: Count Wall Area: Depth: Measurement: 1 Count Sequence: Capture: No The 2015 IBC 1030.1 as amended in City of Aspen 2015 IBC allows for a mezzanine (sleeping loft) without an escape and rescue opening if all of the following conditions are met: - The travel distance from the most remote location of the mezzanine to the dwelling unit entry shall be less than 50 feet (15240 mm) -The mezzanine shall be provided with smoke alarms in addition to those required in Section 907.2.11. - The mezzanine shall be open and unobstructed to the room in which such mezzanine is located except for walls not more than 42 inches (1067 mm) in height, columns and posts. Exception: A portion of the mezzanine is not required to be open to the room in which the mezzanine is located, provided that the aggregate floor area of the enclosed space is not greater than 40 square feet. **Revise bathroom dimensions so that it does not exceed 40 square feet. 46 sf 2 EXISTING LEVEL 2 FLOOR PLAN Loft Open to below Chute Neighboring Unit Unit # 10211'-10"13'-038"14'-1058"3'-9"11'-718"7'-238"10'-1034"2'-0"3'-418"16'-214"The 2015 IBC 1030.1as amended in City ofAspen 2015 IBC allows for amezzanine (sleepingloft) without an escapeand rescue opening ifall of the followingconditions are met:- The travel distance from the most remote location of themezzanine to thedwelling unitentry shall be lessthan 50 feet (15240mm)-The mezzanine shall be provided withsmoke alarms inaddition to thoserequired inSection 907.2.11.- The mezzanine shallbe open andunobstructed to the room in which suchmezzanine islocated except forwalls not more than 42inches (1067 mm) inheight, columns andposts. Exception: A portion ofthe mezzanine is notrequired to be open tothe room in which themezzanineis located, providedthat the aggregatefloor area of the enclosed space is notgreater than 40 squarefeet. **Revise bathroomdimensions so that itdoes not exceed 40 square feet. File Name: Fifth Ave Unit 102 C PLANS.pdf Author: bonniem Subject: PlanCheck Color: Page Label: A-1 EXISTING LEVEL 1 FLOOR PLAN Page Index: 1 Lock: Unlocked Checkmark: Unchecked Date: 9/9/2019 2:32:19 PM Creation Date: 9/9/2019 2:23:09 PM X: 0.3961 in Y: 0.8358 in Document Width: 3.2386 in Document Height: 1.8225 in Length: Unit: Count Wall Area: Depth: Measurement: 1 Count Sequence: Capture: No Provide a detailed narrative addressing how you plan to handle the asbestos containing materials identified in the asbestos report from Health Safe dated 2/19/19. Provide a detailed narrative addressing how you plan to handle the asbestos containing materials identified in the asbestos report from Health Safe dated 2/19/19.