HomeMy WebLinkAboutFile Documents.800 S Mill St.0008-2019-BRES (2)0008-2019-BRES_BuildingComments_1
File Name: Fifth Ave Unit 102 C PLANS.pdf
Author: bonniem
Subject: 3/16" Scale
Color:
Page Label: A-2 PROPOSED LEVEL 2 FLOOR PLAN
Page Index: 4
Lock: Unlocked
Checkmark: Unchecked
Date: 9/9/2019 1:53:22 PM
Creation Date: 9/9/2019 1:53:22 PM
X: 7.0211 in
Y: 2.2428 in
Document Width: 1.7983 in
Document Height: 1.7717 in
Length: 28.46 ft' in"
Unit: sf
Wall Area: 228 sf
Depth: 8.00 ft
Measurement: 46 sf
Sequence:
Capture: No
46 sf
bonniem (3)
File Name: Fifth Ave Unit 102 C PLANS.pdf
Author: bonniem
Subject: PlanCheck
Color:
Page Label: A-2 PROPOSED LEVEL 2 FLOOR PLAN
Page Index: 4
Lock: Unlocked
Checkmark: Unchecked
Date: 9/9/2019 2:17:56 PM
Creation Date: 9/9/2019 2:02:38 PM
X: 0.8046 in
Y: 0.7002 in
Document Width: 8.4201 in
Document Height: 9.4222 in
Length:
Unit: Count
Wall Area:
Depth:
Measurement: 1 Count
Sequence:
Capture: No
The 2015 IBC 1030.1 as
amended in City of Aspen 2015
IBC allows for a mezzanine
(sleeping loft) without an escape
and rescue opening if all of the
following conditions are met:
- The travel distance from the
most remote location of the
mezzanine to the dwelling unit
entry shall be less than 50 feet
(15240 mm)
-The mezzanine shall be
provided with smoke alarms in
addition to those required in
Section 907.2.11.
- The mezzanine shall be open
and unobstructed to the room in
which such mezzanine is
located except for walls not more
than 42 inches (1067 mm) in
height, columns and posts.
Exception: A portion of the
mezzanine is not required to be
open to the room in which the
mezzanine
is located, provided that the
aggregate floor area of the
enclosed space is not greater
than 40 square
feet.
**Revise bathroom dimensions
so that it does not exceed 40
square feet.
46 sf
2 EXISTING LEVEL 2 FLOOR PLAN
Loft
Open to below
Chute
Neighboring Unit
Unit # 10211'-10"13'-038"14'-1058"3'-9"11'-718"7'-238"10'-1034"2'-0"3'-418"16'-214"The 2015 IBC 1030.1as amended in City ofAspen 2015 IBC
allows for amezzanine (sleepingloft) without an escapeand rescue opening ifall of the followingconditions are met:- The travel distance
from the most remote
location of themezzanine to thedwelling unitentry shall be lessthan 50 feet (15240mm)-The mezzanine shall
be provided withsmoke alarms inaddition to thoserequired inSection 907.2.11.- The mezzanine shallbe open andunobstructed to the
room in which suchmezzanine islocated except forwalls not more than 42inches (1067 mm) inheight, columns andposts.
Exception: A portion ofthe mezzanine is notrequired to be open tothe room in which themezzanineis located, providedthat the aggregatefloor area of the
enclosed space is notgreater than 40 squarefeet.
**Revise bathroomdimensions so that itdoes not exceed 40
square feet.
File Name: Fifth Ave Unit 102 C PLANS.pdf
Author: bonniem
Subject: PlanCheck
Color:
Page Label: A-1 EXISTING LEVEL 1 FLOOR PLAN
Page Index: 1
Lock: Unlocked
Checkmark: Unchecked
Date: 9/9/2019 2:32:19 PM
Creation Date: 9/9/2019 2:23:09 PM
X: 0.3961 in
Y: 0.8358 in
Document Width: 3.2386 in
Document Height: 1.8225 in
Length:
Unit: Count
Wall Area:
Depth:
Measurement: 1 Count
Sequence:
Capture: No
Provide a detailed narrative
addressing how you plan to
handle the asbestos containing
materials identified in the
asbestos report from Health
Safe dated 2/19/19.
Provide a detailed narrative addressing
how you plan to handle the asbestos
containing materials identified in the
asbestos report from Health Safe dated
2/19/19.