Gold Bond® BRAND SOUNDBREAK® XP® Wall Board consists
of two pieces of high-density, mold-, mildew- and moisture-
resistant gypsum board, with a specially designed PURPLE®
paper, laminated together with a sound-damping, viscoelastic
SRO\PHU7KLVDFRXVWLFDOO\HQKDQFHG¿UHUHVLVWDQWJ\SVXPFRUHLV
encased in heavy paper that is 100-percent recycled on both sides
DQGRHUVVXSHULRUDEUDVLRQPROGPLOGHZDQGPRLVWXUHUHVLVWDQFH
Use it for high-rated Sound Transmission Class (STC) rated wall and
ceiling assemblies, where sound transmission between rooms or
dwelling units is a concern.
For speed of installation, GridMarX® guide marks are printed on the
paper surface.
Basic Uses
APPLICATIONS
• Use it for interior wall assemblies, where sound transmission
between rooms or dwelling units is a concern.
• 5/8 in. (15.9 mm) SoundBreak XP Wall Board may be
XVHGZKHUH7\SH;*\SVXP%RDUGLVVSHFL¿HGLQ¿UHUDWHG
assemblies.
ADVANTAGES
• Provides high-rated Sound Transmission Class (STC) values per
an independent third-party acoustical laboratory using ASTM
E90 test procedures.
• Achieves high STC values in a thinner wall assembly, increasing
XVDEOHÀRRUVSDFH
• Provides STC Ratings up to 56 for single-layer, steel stud
partitions and up to 67 for area separation walls.
• 6XSHULRUVRXQGGDPSLQJFRVWHFLHQWPDWHULDOWKDW¿QLVKHV
easily and decorates in the same manner as standard
gypsum board.
• For speed of installation and lower installation costs, vertical
board joints do not require acoustical sealant.
• Resists the growth of mold per ASTM D3273 with a score
of 10, the best possible score.
• Resists the growth of mold per ASTM G21 with a score of 0,
the best possible score.
• Heavy abrasion-resistant paper and dense core provide greater
resistance to surface abuse and indentation when tested in
accordance with ASTM C1629.
• Installs like traditional gypsum board without requiring
additional clips or channels.
• Cuts by scoring deeply from both sides before snapping or by
using a hand or power saw.
• Fire-resistant material will not support combustion or transmit
WHPSHUDWXUHVJUHDWO\LQH[FHVVRIÛ)Û&XQWLO
completely calcined, a slow process.
• Dimensionally stable product with negligible expansion and
contraction under normal atmospheric conditions.
• Features the GridMarX® guidemarks on the board to allow for
faster and more accurate installation.
• $FKLHYHV*5((1*8$5'DQG*5((1*8$5'*ROG&HUWL¿FDWLRQ
*5((1*8$5'&HUWL¿HGSURGXFWVDUHFHUWL¿HGWR*5((1*8$5'
standards for low chemical emissions into indoor air during
product usage. For more information, visit: ul.com/gg.
• 4XDOL¿HVDVDORZ92&HPLWWLQJPDWHULDOE\PHHWLQJ&DOLIRUQLD
6SHFL¿FDWLRQ)RUPRUHLQIRUPDWLRQYLVLWcalrecycle.
ca.gov/greenbuilding/specs/section01350/.
Installation Recommendations
GENERAL
• Install gypsum board in accordance with methods described
in ASTM C840 and GA-216.
• Examine and inspect framing materials to which gypsum board
is to be applied. Remedy all defects prior to installation of the
gypsum board.
• *ULG0DU;SURYLGHVTXLFNLGHQWL¿FDWLRQDQGXQLIRUPQDLOVFUHZ
patterns. Use GridMarX to make accurate cuts without drawing
OLQHV*ULG0DU;JXLGHPDUNVUXQWKHOHQJWKRIWKHERDUGDW¿YH
points in 4 in. (102 mm) increments. Marks run along the edge
in both tapers and at 16 in. (406 mm), 24 in. (610 mm) and
LQPPLQWKH¿HOGRIWKHERDUG7KHPDUNVFRYHU
easily with no bleed-through using standard paint products.
• $SSO\J\SVXPERDUG¿UVWWRFHLOLQJVDWULJKWDQJOHVWRIUDPLQJ
members, then to walls. Use boards of maximum practical
length so that the minimum number of end joints occur.
Bring board edges into contact with each other but do not
force into place.
• Install batt or blanket ceiling insulation BEFORE the gypsum
board on ceilings when installing a vapor retarder behind
the gypsum board. Install the insulation IMMEDIATELY after
WKHJ\SVXPERDUGZKHQXVLQJORRVH¿OOLQVXODWLRQ$YRLG
installation practices that might allow condensation to form
behind boards.
(Continued on Page 3)
JOB NAME:
CONTRACTOR:
DATE:
SUBMITTAL APPROVALS: (STAMPS OR SIGNATURES)
1
GOLD BOND® BRAND
SOUNDBREAK XP®
WALL BOARD
Technical Information:
800-NATIONAL
800-628-4662
09 29 00/NGC
PHYSICAL PROPERTIES
1/2" SoundBreak XP Wall Board 5/8" SoundBreak XP Wall Board
Thickness1, Nominal 1/2" (12.7 mm) 5/8" (15.9 mm)
Width1, Nominal 4' (1,219 mm) 4' (1,219 mm)
Length1,4, Standard 8' – 12' (2,438 mm - 3,658 mm)8' – 12' (2,438 mm - 3,658 mm)
Weight, Nominal 2.3 lbs./sq. ft. (11.23 k/m2) 2.7 lbs./sq. ft.(13.18 k/m
2)
Edges1 Slightly Tapered Slightly Tapered
Flexural Strength1, Perpendicular OEI1 OEI1
Flexural Strength1, Parallel OEI1 OEI1
+XPLGL¿HG'HÀHFWLRQ1 10/8" (31.8 mm) 5/8" (15.9 mm)
Nail Pull Resistance1 77 lbf. (343 N) 87 lbf. (387 N)
Hardness1 – Core, Edges and Ends 11 lbf. (49 N) 11 lbf. (49 N)
Bending Radius 10' (3,048 mm) 15' (4,572 mm)
Thermal Resistance5 R = .45 R = .56
Permeance6 45 perms 37 perms
Mold Resistance7, ASTM D3273 Score of 10 Score of 10
Mold Resistance8, ASTM G21 Score of 0 Score of 0
Surface Abrasion9 Level 3 Level 3
Indentation9 Level 1 Level 1
Soft-Body Impact9 Level 1 Level 2
Hard-Body Impact9 N/A Level 1
Product Standard Compliance ASTM C 1396, C1766 ASTM C 1396, C1766
Fire-Resistance Characteristics
Core Type Regular Type X
UL Type Designation N/A SoundBreak XP
Combustibility2 Non-combustible Core Non-combustible Core
Surface Burning Characteristics3 Class A Class A
Flame Spread3 15 15
Smoke Development3 00
Applicable Standards and References
ASTM C473 Standard Test Methods for Physical Testing of Gypsum Panel Products
ASTM C518 Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus
$670&6WDQGDUG6SHFL¿FDWLRQIRU$SSOLFDWLRQDQG)LQLVKLQJRI*\SVXP%RDUG
$670&6WDQGDUG6SHFL¿FDWLRQIRU*\SVXP%RDUG
$670&6WDQGDUG&ODVVL¿FDWLRQIRU$EXVH5HVLVWDQW1RQGHFRUDWHG,QWHULRU*\SVXP3DQHO3URGXFWVDQG)LEHU5HLQIRUFHG&HPHQW3DQHOV
ASTM D3273 Standard Test Method for Resistance to Growth of Mold on the Surface of Interior Coatings in an Environmental Chamber
ASTM E84 Standard Test Method for Surface Burning Characteristics of Building Materials
$670(6WDQGDUG7HVW0HWKRGVIRU:DWHU9DSRU7UDQVPLVVLRQRI0DWHULDOV
$670(6WDQGDUG7HVW0HWKRGIRU%HKDYLRURI0DWHULDOVLQD9HUWLFDO7XEH)XUQDFHDWÛ&
ASTM G21 Standard Practice for Determining Resistance of Synthetic Polymeric Materials to Fungi
Gypsum Association, GA-214, Recommended Levels of Finish for Gypsum Board, Glass Mat and Fiber-Reinforced Gypsum Panels
Gypsum Association, GA-216, Application and Finishing of Gypsum Panel Products
Gypsum Association, GA-238, Guidelines for Prevention of Mold Growth on Gypsum Board
National Gypsum Company, NGC Construction Guide
1. 6SHFL¿HGYDOXHVSHU$670&WHVWHGLQDFFRUGDQFHZLWK$670&
2. Tested in accordance with ASTM E136.
3. Tested in accordance with ASTM E84
4. Please consult your local sales representative for all non-standard lengths and widths. Minimum order requirements may apply.
5. Tested in accordance with ASTM C518.
6. Tested in accordance with ASTM E96.
7. Tested in accordance with ASTM D3273.
8. Tested in accordance with ASTM G21.
9. Tested in accordance with ASTM methods in ASTM C1629 – D4977 (Surface Abrasion), D5420 (Indentation), E695 (Soft-Body Impact), Annex A1 (Hard-Body Impact).
2
33
(Continued from Page 1)
• Cut gypsum board to allow for a minimum 1/4 in. (6.4 mm)
JDSEHWZHHQJ\SVXPERDUGDQGÀRRUWRSUHYHQWSRWHQWLDO
wicking of moisture.
• Provide minimum 1/4 in. (6.4 mm) clearance between boards
and adjacent concrete or masonry to minimize wicking of
moisture.
• Locate gypsum board joints at openings so that no joint will
align within 12 in. (305 mm) of the edges of the opening
unless installing control joints at these locations. Stagger
vertical end joints. Joints on opposite sides of a partition
should not occur on the same stud.
• +ROGJ\SVXPERDUGLQ¿UPFRQWDFWZLWKWKHIUDPLQJPHPEHU
while driving fasteners. Fastening should proceed from center
portion of the board toward the edges and ends. Set fasteners
with heads slightly below the surface of the board. Take
care to avoid breaking the face paper of the gypsum board.
Remove improperly driven nails or screws.
• 0DLQWDLQDURRPWHPSHUDWXUHRIQRWOHVVWKDQÛ)Û&
during application of gypsum board.
• 0DLQWDLQDURRPWHPSHUDWXUHRIQRWOHVVWKDQÛ)Û&
when using adhesive to attach gypsum board and during joint
treatment, texturing and decoration, beginning 48 hours prior
to application and continuously thereafter until completely
dry. Maintain adequate ventilation in the working area during
installation and curing period.
FINISHING
-RLQWVEHWZHHQ6RXQG%UHDN;3:DOO%RDUGPD\EH¿QLVKHGZLWK
HLWKHUSDSHUWDSHDQGUHDG\PL[MRLQWFRPSRXQGRU¿EHUJODVVPHVK
or paper tape and setting compound, such as ProForm® BRAND
Interior Finishing Products.
DECORATION
(QVXUHJ\SVXPERDUGVXUIDFHVLQFOXGLQJ¿QLVKHGMRLQWVDUHFOHDQ
dust-free and gloss-free to achieve best painting results. Apply a
coat of a quality drywall primer to equalize the porosities between
surface paper and joint compound, improving fastener and joint
concealment.
6HOHFWLRQRIDSDLQWWRSURYLGHGHVLUHG¿QLVKFKDUDFWHULVWLFVLVWKH
responsibility of the architect or contractor.
Prepare and prime gypsum boards prior to texturing.
5HIHUWR*$WRGHWHUPLQHWKHOHYHORI¿QLVKLQJQHHGHGWR
assure a surface properly prepared to accept the desired decoration.
CRITICAL LIGHTING AREAS
Wall and ceiling areas abutting window mullions or skylights,
long hallways, and atriums with large surface areas washed with
DUWL¿FLDORUQDWXUDOOLJKWLQJDUHDIHZH[DPSOHVRIFULWLFDOOLJKWLQJ
areas. Strong side lighting from windows or surface-mounted
OLJKW¿[WXUHVPD\UHYHDOPLQRUVXUIDFHLPSHUIHFWLRQV/LJKWVWULNLQJ
the surface obliquely, at a slight angle, exaggerates surface
GOLD BOND® BRAND
SOUNDBREAK XP®
WALL BOARD
Technical Information:
800-NATIONAL
800-628-4662
09 29 00/NGC
irregularities. If you cannot avoid critical lighting, minimize the
HHFWVE\VNLPFRDWLQJWKHJ\SVXPERDUGVXUIDFHVE\GHFRUDWLQJ
the surface with medium to heavy textures, or by the use of
draperies and blinds, which soften shadows. In general, paints
ZLWKVKHHQOHYHOVRWKHUWKDQÀDWHQDPHOSDLQWVDQGGDUNWRQHG
SDLQW¿QLVKHVKLJKOLJKWVXUIDFHGHIHFWVFRQVLGHUXVLQJWH[WXUHV
to hide these minor visual imperfections. Finish boards to a Level 5
¿QLVKDVRXWOLQHGLQ*$
Limitations
• Avoid exposure to excessive or continuous moisture and
extreme temperatures. Do not expose gypsum board to
WHPSHUDWXUHVH[FHHGLQJÛ)Û&IRUH[WHQGHGSHULRGVRI
time.
• Properly ventilate or condition attic spaces to remove moisture
buildup above gypsum board ceilings. If required, install a
vapor retarder in exterior ceilings behind gypsum board.
• Avoid installing gypsum board directly over insulation blankets
ZLWKIDFHUÀDQJHVSODFHGFRQWLQXRXVO\DFURVVWKHIDFHRI
WKHIUDPLQJPHPEHUVUHFHVVLQVXODWLRQEODQNHWVDQGDWWDFK
ÀDQJHVWRWKHVLGHVRIIUDPLQJ
• Isolate gypsum board from contact with building structure in
locations where structural movement may impose direct loads
on gypsum board assemblies.
• Provide control joints spaced not more than 30 ft. (9,144 mm)
where employing long continuous runs of walls, partitions or
ceilings without perimeter relief.
• Avoid gypsum board joints within 12 in. (305 mm) of the
corners of window or door frames unless installing control
joints at these locations.
• In single-ply installation, all ends and edges of gypsum board
should occur over framing members or other solid backing
except where treated joints occur at right angles to framing or
furring members.
• Apply 1/2 in. (12.7 mm) gypsum board ceilings to be decorated
with water-based spray texture perpendicular to the framing
spaced a maximum of 16 in. (406 mm) o.c.
• Space supporting framing for single-layer application of 1/2 in.
(12.7 mm) gypsum board a maximum of 24 in. (610 mm) o.c.
• Do not use boards as a nailing base as they are nonstructural.
• Avoid using in areas subject to constant and/or excessive
moisture and high humidity, such as gang showers, saunas,
steam rooms or swimming pool enclosures.
• Avoid using as a backer board directly behind tile in tub and
shower areas.
• Do not install in pre-rock conditions.
• 'RQRW¿QLVKMRLQWVXQWLOEXLOGLQJLVSURSHUO\FORVHGLQDQG
conditioned.
4
2001 Rexford Road
Charlotte, NC 28211
(704) 365-7300
NationalGypsum.com
AskForPurple.com 111022 Rev. 09/19 4
For More Information
ARCHITECTURAL SPECIFICATIONS
National Gypsum Company’s CSI Master Format® 3-part guide
VSHFL¿FDWLRQVDUHGRZQORDGDEOHDVHGLWDEOH0LFURVRIW:RUG
documents at: nationalgypsum.com.
LATEST INFORMATION AND UPDATES
For the latest technical information and updates, call NGC
Construction Services: 1-800-NATIONAL (628-4662) or visit
our website: nationalgypsum.com.