HomeMy WebLinkAboutFile Documents.971 Ute Ave. M#48
M#48
Right side view
Model No.
Viewing Area
Exterior Dimension
Framing Dimension
Gas Type*
Gas Connection
On/Off
Efficiency
Venting Options
Vent Type
Fan
Electric
BTU input Natural gas
BTU input LP/propane
Doors/glass
Interior Color
Sustained operating gas pressure
parameters:
Certifications
Options
*Must be specified at time of ordering.
Note:
This is a high throughput gas
appliance and critical attention
is needed to size the gas pipes
properly.
48
48.75" W x 13.75" H
57.25" W x 28" H x 22.25" D
60" W x 34.5" H x 23.75" D
Natural or LP/Propane
1/2" pipe
Programmable / thermostatic remote
control standard
Up to 80%
Through exterior wall or vertical through roof,
Must vent 1' vertically before horizontal venting.
Duravent DirectVent Pro 58DVA
Must source locally, not included.
Thermostat activated 160 c.f.m.
110 V
27,000 - 39,000 BTU/h
27,000 - 38,000 BTU/h
Fixed ceramic glass panel
Satin Black
Natural gas 4.5" - 10.5" w.c.
LP/propane 11.0" - 13.0" w.c.
Omni-Test Laboratories ANSI Z21.88 -2014,
CSA 2.33 -2014, CGA 2.17 M91 (R2009),
CSA P.4.1-09
Fire Objects
Media Tray, required when using fire objects
Fire Ribbon Direct Vent 4 ft with mandatory safety screen
Top view
Front view
City of Aspen
Received
5/11/17
Building Department