HomeMy WebLinkAboutFile Documents.905 Chatfield Rd.0111.2018 (80).ARBKAir System Sizing Summary for Whole House Project Name: 17085-Silverstein Residence 03/27/2018 Prepared by: RADER ENGINEERING INC.01:36PM Air System Information Air System Name Whole House Equipment Class UNDEF Air System Type SZCAV Number of zones 1 Floor Area 5010.0 ft² Location Eagle, Colorado Sizing Calculation Information Calculation Months Jan to Dec Sizing Data Calculated Zone CFM Sizing Sum of space airflow rates Space CFM Sizing Individual peak space loads Central Cooling Coil Sizing Data Total coil load 10.0 Tons Total coil load 119.8 MBH Sensible coil load 113.8 MBH Coil CFM at Jul 1700 8704 CFM Max block CFM 8704 CFM Sum of peak zone CFM 8704 CFM Sensible heat ratio 0.950 CFM/Ton 872.0 ft²/Ton 501.9 BTU/(hr·ft²)23.9 Water flow @ 10.0 °F rise 23.97 gpm Load occurs at Jul 1700 OA DB / WB 86.4 / 64.0 °F Entering DB / WB 73.1 / 61.0 °F Leaving DB / WB 56.8 / 55.7 °F Coil ADP 55.0 °F Bypass Factor 0.100 Resulting RH 54 % Design supply temp.55.0 °F Zone T-stat Check 1 of 1 OK Max zone temperature deviation 0.0 °F Central Heating Coil Sizing Data Max coil load 114.8 MBH Coil CFM at Des Htg 8704 CFM Max coil CFM 8704 CFM Water flow @ 20.0 °F drop 11.49 gpm Load occurs at Des Htg BTU/(hr·ft²)22.9 Ent. DB / Lvg DB 69.5 / 85.9 °F Humidifier Sizing Data Max steam flow at Des Htg 5.08 lb/hr Airflow Rate 8704 CFM Air mass flow 29205.44 lb/hr Moisture gain .00017 lb/lb Supply Fan Sizing Data Actual max CFM 8704 CFM Standard CFM 6490 CFM Actual max CFM/ft²1.74 CFM/ft² Fan motor BHP 1.79 BHP Fan motor kW 1.42 kW Fan static 0.75 in wg Outdoor Ventilation Air Data Design airflow CFM 0 CFM CFM/ft²0.00 CFM/ft² CFM/person 0.00 CFM/person Hourly Analysis Program 5.11 Page 1 of 2 4/19/18 04/26/2018 Zone Sizing Summary for Whole House Project Name: 17085-Silverstein Residence 03/27/2018 Prepared by: RADER ENGINEERING INC.01:36PM Air System Information Air System Name Whole House Equipment Class UNDEF Air System Type SZCAV Number of zones 1 Floor Area 5010.0 ft² Location Eagle, Colorado Sizing Calculation Information Calculation Months Jan to Dec Sizing Data Calculated Zone CFM Sizing Sum of space airflow rates Space CFM Sizing Individual peak space loads Zone Terminal Sizing Data Zone Name Design Supply Airflow (CFM) Minimum Supply Airflow (CFM) Zone CFM/ft² Reheat Coil Load (MBH) Reheat Coil Water gpm @ 20.0 °F Zone Htg Unit Coil Load (MBH) Zone Htg Unit Water gpm @ 20.0 °F Mixing Box Fan Airflow (CFM) Whole House 8704 8704 1.74 0.0 0.00 0.0 0.00 0 Zone Peak Sensible Loads Zone Zone Zone Cooling Time of Heating Floor Sensible Peak Sensible Load Area Zone Name (MBH)Cooling Load (MBH)(ft²) Whole House 114.9 Aug 1600 117.3 5010.0 Space Loads and Airflows Zone Name / Space Name Mult. Cooling Sensible (MBH) Time of Peak Sensible Load Air Flow (CFM) Heating Load (MBH) Floor Area (ft²) Space CFM/ft² Whole House 001 Rec Room 1 2.4 Jul 1500 174 3.5 542.0 0.32 002 Laundry 1 1.1 Jul 1500 78 0.5 56.0 1.40 004 Bedroom 1 1 2.8 Jul 1700 202 3.1 235.0 0.86 004-A Bath 1 1 0.6 Jul 1700 41 0.7 51.0 0.81 005 Bedroom 2 1 1.4 Jul 1500 104 1.8 186.0 0.56 005-A Bath 2 1 0.9 Jul 1500 66 0.7 70.0 0.95 006 Bedroom 3 1 1.5 Jul 1500 106 2.0 210.0 0.51 006-A Bath 3 1 0.6 Jul 1500 45 1.1 60.0 0.75 100 Entry 1 27.6 Jul 1600 2014 28.3 539.0 3.74 102 Powder 1 1.6 Sep 1400 114 1.7 38.0 3.01 103 Den 1 5.4 Jul 1500 397 5.8 170.0 2.34 104 Kitchen & Pantry 1 17.2 Sep 1500 1257 11.9 453.0 2.78 105 Dining & Living 1 25.6 Sep 1600 1868 23.9 529.0 3.53 107 Master Bedroom 1 7.3 Jul 1600 536 7.0 313.0 1.71 108 Master Bath 1 2.8 Sep 1600 206 2.3 121.0 1.70 109 Garage 1 4.1 Aug 1600 377 9.1 481.0 0.78 110 Mudroom 1 0.3 Jul 1500 22 0.5 66.0 0.33 111 Master Closet 1 0.4 Jul 1500 26 0.3 90.0 0.28 200 Office 1 3.7 Aug 1600 270 3.8 221.0 1.22 201 Guest Bedroom 1 1 3.5 Aug 1600 253 3.0 204.0 1.24 202 Guest Bath 1 1 1.3 Aug 1600 96 0.8 72.0 1.33 203 Guest Bedroom 2 1 5.0 Aug 1600 362 4.6 242.0 1.50 204 Guest Bath 2 1 1.2 Aug 1300 90 1.1 61.0 1.47 Hourly Analysis Program 5.11 Page 2 of 2 04/26/2018