Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
File Documents.905 Chatfield Rd.0111.2018 (97).ARBK
POWER OPTIMIZERwww.solaredge.usUSA - GERMANY - ITALY - FRANCE - JAPAN - CHINA - ISRAEL - AUSTRALIA SolarEdge Power Optimizer Module Add-On For North America P300 / P400 / P405 Up to 25% more energy Superior efficiency (99.5%) Mitigates all types of module mismatch losses, from manufacturing tolerance to partial shading Flexible system design for maximum space utilization Fast installation with a single bolt Next generation maintenance with module-level monitoring Module-level voltage shutdown for installer and firefighter safety PV power optimization at the module-level 12/03/2018 © SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 09/2014 V.01. Subject to change without notice. (2) It is not allowed to mix P405 with P300/P400/P600/P700 in one string. P300 (for 60-cell modules) P400 (for 72 & 96-cell modules) P405 (for thin film modules) INPUT Rated Input DC Power(1)300 400 405 W Absolute Maximum Input Voltage (Voc at lowest temperature) 48 80 125 Vdc MPPT Operating Range 8 - 48 8 - 80 12.5 - 105 Vdc Maximum Short Circuit Current (Isc) 10 Adc Maximum DC Input Current 12.5 Adc Maximum Efficiency 99.5 % Weighted Efficiency 98.8 % Overvoltage Category II OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING INVERTER) Maximum Output Current 15 Adc Maximum Output Voltage 60 85 Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) Safety Output Voltage per Power Optimizer 1 Vdc STANDARD COMPLIANCE EMC FCC Part15 Class B, IEC61000-6-2, IEC61000-6-3 Safety IEC62109-1 (class II safety), UL1741 RoHS Yes INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Dimensions (W x L x H) Pxxx-2 series 141 x 212 x 40.5 / 5.55 x 8.34 x 1.59 mm / in Pxxx-5 series 128 x 152 x 27.5 / 5 x 5.97 x 1.08 128 x 152 x 35 / 5 x 5.97 x 1.37 128 x 152 x 48 / 5 x 5.97 x 1.89 mm / in Weight (including cables)Pxxx-2 series 950 / 2.1 gr / lb Pxxx-5 series 770 / 1.7 930 / 2.05 930 / 2.05 gr / lb Input Connector MC4 Compatible Output Wire Type / Connector Double Insulated; Amphenol Output Wire Length 0.95 / 3.0 1.2 / 3.9 m / ft Operating Temperature Range -40 - +85 / -40 - +185 ˚C / ˚F Protection Rating Pxxx-2 series IP65 / NEMA4 Pxxx-5 series IP68 / NEMA6P Relative Humidity 0 - 100 % (1) Rated STC power of the module. Module of up to +5% power tolerance allowed. SolarEdge Power Optimizer Module Add-On for North America P300 / P400 / P405 PV SYSTEM DESIGN USING A SOLAREDGE INVERTER(2)SINGLE PHASE THREE PHASE 208V THREE PHASE 480V Minimum String Length (Power Optimizers) 8 10 18 Maximum String Length (Power Optimizers)25 25 50 Maximum Power per String 5250 6000 12750 W Parallel Strings of Different Lengths or Orientations Yes 12/03/2018