HomeMy WebLinkAboutFile Documents.45 Callahan Ct.0014.2017 (11).ACBK�E CON
ENVIRONMENTAL CONSULTANTS
...bventhe ease...
Final Clearance Air Monitorinq Services
Date: April 19, 2017
Project: Abatement of ACM cement asbestos board panels from two
window panel work areas at The Meadows Reception Center, Aspen,
Colorado 81611.
Contractor: Prestige Environmental Services, Aurora, Colorado
Air Monitoring Description:
Phase Con provided final clearance air monitoring services at the project
site listed above on April 19, 2017. Air samples were situated inside the
enclosure so as to be representative of the entire work space. Air
samples were obtained utilizing aggressive sampling methods to aid in
ensuring that any fibrous material left in the enclosure would be
entrained in the air during the sampling period.
Abatement Description:
Abatement of ACM cement asbestos board panels from two window
panel work areas.
Comments and Recommendations:
PCM analysis of the final clearance air samples revealed airborne fiber
levels inside the containment area(s) to be less than the Colorado State
Maximum Allowable Asbestos Level (MAAL) and the EPA clearance level
of 0.010 fibers per cubic centimeter of air; therefore, the area(s) may
be re%ecs;ubied under non -abatement conditions.
A. Close
i State Air Monitoring Specialist #2930
2166 Perearine Court
Grand Junction, CO 81507
Office: 970-260-3341 pceconsultants@gwestoffice.net
SE CON
ENVIRONMENTAL CONSULTANTS
...breathe easLu...
PCM LABORATORY ANALYSIS
OSHA Reference Method - NIOSH 7400
Client: The Aspen Institute Sampling Date: 4/19/17
Aspen, Colorado Technician/Analyst: D. Close
Project: The Meadows Reception Center CDPHE Technician ID: 2930
Aspen, Colorado
Abatement Contractor: Prestige Environmental Services, Aurora, Colorado
Description of Work: Abatement of ACM cement asbestos board panels from
Two window panel work areas.
SAMPLE SAMPLE DESCRIPTION AIR VOLUME fibers/fields
ID f/cc
01
Final Clearance Sample -
446 L
2.0/100
Lower Level Transite Panel Work Area
<0.008 f/cc
02
Final Clearance Sample -
446 L
2.5/100
Lower Level Transite Panel Work Area
<0.008 F CC
03
Final Clearance Sample -
446 L
2.0/100
Lower Level Transite Panel Work Area
<0.008 F/CC
04
Final Clearance Sample -
446 L
3.5/100
Upper Level Transite Panel Work Area
<0.008 F CC
05
Final Clearance Sample -
446 L
2.0/100
Upper Level Transite Panel Work Area
<0.008 F CC
06
Blank
-----
NONE
DETECTED
07
Blank
-----
NONE
DETECTED
* Colorado State Clearance Level is 0.010 f/cc of air
r
Technician/Analyst:
2166 Peregrine Court
Grand Junction, CO 81507
Office: 970-260-3341 pceconsultants@gwestoffice.net
Certificates
y
of Public Health
and Environment
ASBESTOS
commission xeguianon rio. a, ran n, ano is nereoy cemneu oy Lne
state of Colorado in the following discipline:
Air Monitoring Specialist*
Yy
"
Issued: November 04, 2016
vk
Expires: December 08, 2017
_
y.
77ds emire.to is valid a.1, e'i h the possession Ofa
current Division -approved training course certification '! a
b.in
du discipline specified above. Authoften APCD Representative
SEAL
j
} Y
__t7V
.i