Loading...
HomeMy WebLinkAboutFile Documents.45 Callahan Ct.0014.2017 (11).ACBK�E CON ENVIRONMENTAL CONSULTANTS ...bventhe ease... Final Clearance Air Monitorinq Services Date: April 19, 2017 Project: Abatement of ACM cement asbestos board panels from two window panel work areas at The Meadows Reception Center, Aspen, Colorado 81611. Contractor: Prestige Environmental Services, Aurora, Colorado Air Monitoring Description: Phase Con provided final clearance air monitoring services at the project site listed above on April 19, 2017. Air samples were situated inside the enclosure so as to be representative of the entire work space. Air samples were obtained utilizing aggressive sampling methods to aid in ensuring that any fibrous material left in the enclosure would be entrained in the air during the sampling period. Abatement Description: Abatement of ACM cement asbestos board panels from two window panel work areas. Comments and Recommendations: PCM analysis of the final clearance air samples revealed airborne fiber levels inside the containment area(s) to be less than the Colorado State Maximum Allowable Asbestos Level (MAAL) and the EPA clearance level of 0.010 fibers per cubic centimeter of air; therefore, the area(s) may be re%ecs;ubied under non -abatement conditions. A. Close i State Air Monitoring Specialist #2930 2166 Perearine Court Grand Junction, CO 81507 Office: 970-260-3341 pceconsultants@gwestoffice.net SE CON ENVIRONMENTAL CONSULTANTS ...breathe easLu... PCM LABORATORY ANALYSIS OSHA Reference Method - NIOSH 7400 Client: The Aspen Institute Sampling Date: 4/19/17 Aspen, Colorado Technician/Analyst: D. Close Project: The Meadows Reception Center CDPHE Technician ID: 2930 Aspen, Colorado Abatement Contractor: Prestige Environmental Services, Aurora, Colorado Description of Work: Abatement of ACM cement asbestos board panels from Two window panel work areas. SAMPLE SAMPLE DESCRIPTION AIR VOLUME fibers/fields ID f/cc 01 Final Clearance Sample - 446 L 2.0/100 Lower Level Transite Panel Work Area <0.008 f/cc 02 Final Clearance Sample - 446 L 2.5/100 Lower Level Transite Panel Work Area <0.008 F CC 03 Final Clearance Sample - 446 L 2.0/100 Lower Level Transite Panel Work Area <0.008 F/CC 04 Final Clearance Sample - 446 L 3.5/100 Upper Level Transite Panel Work Area <0.008 F CC 05 Final Clearance Sample - 446 L 2.0/100 Upper Level Transite Panel Work Area <0.008 F CC 06 Blank ----- NONE DETECTED 07 Blank ----- NONE DETECTED * Colorado State Clearance Level is 0.010 f/cc of air r Technician/Analyst: 2166 Peregrine Court Grand Junction, CO 81507 Office: 970-260-3341 pceconsultants@gwestoffice.net Certificates y of Public Health and Environment ASBESTOS commission xeguianon rio. a, ran n, ano is nereoy cemneu oy Lne state of Colorado in the following discipline: Air Monitoring Specialist* Yy " Issued: November 04, 2016 vk Expires: December 08, 2017 _ y. 77ds emire.to is valid a.1, e'i h the possession Ofa current Division -approved training course certification '! a b.in du discipline specified above. Authoften APCD Representative SEAL j } Y __t7V .i