Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
File Documents.835 E Hyman Ave.0017.2018 (19).ARBK
11/16 Installation Details 30" Undercabinet Hood 300 Series – Stainless Steel DUH30152UC For help and assistance with Bosch accessories please visit: www.bosch-eshop.com/eshop/bosch/us or call 1-800-944-2904 Mon-Fri 5am to 6pm PST Sat 6am to 3pm PST Notes: All height, width and depth dimensions are shown in inches. BSH reserves the absolute and unrestricted right to change product materials and specifications, at any time, without notice. Consult the product’s installation instructions for final dimensional data and other details prior to making cutout. Applicable product warranty can be found in accompanying product literature or you may contact your account manager for further details. Warranties: Bosch warrants that the Product is free from defects in materials and workmanship for a period of three hundred and sixty-five (365) days from the date of purchase. The foregoing timeline begins to run upon the date of purchase, and shall not be stalled, tolled, extended, or suspended, for any reason whatsoever. This Product is also warranted to be free from cosmetic defects in material and workmanship (such as scratches of stainless steel, paint/porcelain blemishes, chip, dents, or other damage) to the finish of the Product, for a period of thirty (30) days from the date of purchase or closing date for new construction. This cosmetic warranty excludes slight color variations due to inherent differences in painted and porcelain parts, as well as differences caused by kitchen lighting, product location, or other similar factors. This cosmetic warranty specifically excludes any display, floor, “As Is”, or “B” stock appliances. For more information on our entire line of products, go to www.bosch-home.com/us or call 1-800-944-2904 © BSH Home Appliances Corporation. All rights reserved. Bosch is a registered trademark of Robert Bosch GmbH. 01/29/2018 1Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17 Installation Manual Installation and Appliance Setup INSTALLER: Leave this manual with party responsible for use and operation. OWNER: Retain this manual for future reference. NOTICE: DO NOT discard this manual! In the Commonwealth of Massachusetts installation must be performed by a licensed plumber or gas fitter. See Table of Contents for location of additional Commonwealth of Massachusetts requirements. • DO NOT store or use gasoline or other flam- mable vapors and liquids in the vicinity of this or any other appliance. • What to do if you smell gas - DO NOT try to light any appliance. - DO NOT touch any electrical switch. DO NOT use any phone in your building. - Leave the building immediately. - Immediately call your gas supplier from a neighbor’s phone. Follow the gas sup- plier’s instructions. - If you cannot reach your gas supplier, call the fire department. • Installation and service must be performed by a qualified installer, service agency, or the gas supplier. WARNING: FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury, death, or property damage. Models: COSMO42-IFT COSMO32-IFT This appliance may be installed as an OEM installation in manufactured home (USA only) or mobile home and must be installed in accordance with the manufacturer’s instructions and the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 in the United States, or the Standard for Installation in Mobile Homes, CAN/CSA Z240 MH Series, in Canada. This appliance is only for use with the type(s) of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used. DANGER HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS UNTIL COOLED. NEVER ALLOW CHILDREN TO TOUCH GLASS. A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed for the protection of children and other at-risk individuals. 01/29/2018 Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/172 Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury. • WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury. • CAUTION! Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. • NOTICE: Used to address practices not related to personal injury. Table of Contents Installation Standard Work Checklist ....................3 1 Product Specific and Important Safety Information A. Appliance Certification ............................4 B. Glass Specifications ..............................4 C. BTU Specifications ...............................4 D. High Altitude Installations ..........................4 E. Non-Combustible Materials Specification. . . . . . . . . . . . . . 5 F. Combustible Materials Specification .................5 G. Electrical Codes .................................5 H. Requirements for the Commonwealth of Massachusetts . .6 2 Getting Started A. Design and Installation Considerations ...............7 B. Good Faith Wall Surface ..........................7 C. Tools and Supplies Needed ........................7 D. Inspect Appliance and Components ..................8 3 Framing and Clearances A. Appliance/Decorative Front Dimension Diagrams .......9 B. Clearances to Combustibles ......................13 C. Constructing the Appliance Chase ..................15 4 Termination Location and Vent Information A. Vent Termination Minimum Clearances ..............16 B. Chimney Diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 C. Approved Pipe .................................18 D. Use of Elbows .................................19 E. Measuring Standards ............................20 F. Use of Flex Vent (SLP-FLEX Series 6-5/8 Inch) .......21 G. Vent Diagrams .................................21 5 Vent Clearances and Framing A. Pipe Clearances to Combustibles ..................33 B. Wall Penetration Framing/Firestops .................33 C. Ceiling Firestop/Floor Penetration Framing ...........34 D. Install Attic Insulation Shield .......................34 6 Appliance Preparation A. Vent Collar Preparation ..........................35 B. Installing Optional Heat Management Systems ........36 C. Securing and Leveling the Appliance ................36 D. Non-Combustible Material Installation ...............37 7 Venting and Chimneys A . Assemble Vent Sections .........................38 B. Assemble Slip Sections ..........................39 C. Secure the Vent Sections .........................40 D. Disassemble Vent Sections .......................40 E. Vertical Termination Requirements ..................41 F. Horizontal Termination Requirements ...............42 8 Electrical Information A. General Information .............................44 B. Wiring Requirements ............................45 9 Gas Information A. Fuel Conversion ................................49 B. Gas Pressure ..................................49 C. Gas Connection ................................51 D. High Altitude Installations .........................51 E. Air Shutter Setting ..............................51 10 Finishing A. Facing Materials ................................52 B. Non-Combustible Board and Drywall Installation .......53 C. Mantel and Wall Projections .......................55 D. Decorative Front Finishing ........................57 11 Appliance Setup A. Remove Fixed Glass Assembly ....................60 B. Remove the Shipping Materials ....................60 C. Clean the Appliance .............................60 D. Install the Glass Refractory (Optional) ..............60 E. Install LED Lights (Optional) ......................61 F. Install Media ..................................61 G. Install Stones (Optional) .........................61 H. Install Log Sets (Optional) . . . . . . . . . . . . . . . . . . . . . . . . 61 I. Install Fixed Glass Assembly ......................61 J. Install Decorative Front ..........................62 12 Reference Materials A. Vent Components Diagrams ......................63 B. Accessories ...................................69 = Contains updated information.01/29/2018 3Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17 Installation Standard Work Checklist Customer: Lot/Address: Model (circle one): COSMO42-IFT COSMO32-IFT Date Installed: Location of Fireplace: Installer: Dealer/Distributor Phone # Serial #: Comments: Further description of the issues, who is responsible (Installer/ Builder/ Other Trades, etc) and corrective action needed _____________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ Comments Communicated to party responsible ____________________ by ______________________on ___________ (Builder / Gen. Contractor/) (Installer) (Date) Appliance Install YES IF NO, WHY? Verified that the chase is insulated and sealed. (Pg. 15) ___________________________ Required non-combustible board is installed. (Pg. 37) ___________________________ Verified clearances to combustibles. (Pg. 13-14) ___________________________ Fireplace is leveled and secured. (Pg. 36) ___________________________ Venting/Chimney Section 7 (Pg 38-43) Venting configuration complies to vent diagrams. ___________________________ Venting installed, locked and secured in place with proper clearance. ___________________________ Firestops installed. ___________________________ Attic insulation shield installed. ___________________________ Exterior wall/Roof flashing installed and sealed. ___________________________ Terminations installed and sealed. ___________________________ Electrical Section 8 (Pg 44-48) Unswitched power (110-120 VAC) provided to the appliance. ___________________________ Switch wires properly installed. ___________________________ Gas Section 9 (Pg 49-51) Proper appliance for fuel type. ___________________________ Was a conversion performed? ___________________________ Leak check performed and inlet pressure verified. ___________________________ Verified proper air shutter setting for installation type. ___________________________ Finishing Section 10 (Pg 52-59) Combustible materials not installed in non-combustible areas. ___________________________ Verified all clearances meet installation manual requirements. ___________________________ Mantels and wall projections comply with installation manual requirements. ___________________________ Appliance Setup Section 11 (Pg 60-62) All packaging and protective materials removed (inside & outside of appliance). ___________________________ Media and optional logs, glass refractory and LED’s installed correctly. ___________________________ Glass assembly installed and secured. ___________________________ Accessories installed properly. ___________________________ Mesh, doors, or decorative front properly installed. ___________________________ Manual bag and all of its contents are removed from inside/under the appliance and given to party responsible for use and operation. ___________________________ Started appliance and verified no gas leaks exist. ___________________________ 2491-982 9/17 = Contains updated information. Hearth & Home Technologies recommends the following: • Photographing the installation and copying this checklist for your file. • That this checklist remain visible at all times on the appliance until the installation is complete. This standard work checklist is to be used by the installer in conjunction with, not instead of, the instructions contained in this installation manual. WARNING! Risk of Fire or Explosion! Failure to install appliance according to these instructions could lead to a fire or explosion. ATTENTION INSTALLER: Follow this Standard Work Checklist 01/29/2018 Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/174 B. Glass Specifications Hearth & Home Technologies appliances manufactured with tempered glass may be installed in hazardous lo- cations such as bathtub enclosures as defined by the Consumer Product Safety Commission (CPSC). The tempered glass has been tested and certified to the re- quirements of ANSI Z97.1 and CPSC 16 CFR 1202 (Safety Glazing Certification Council SGCC# 1595 and 1597. Architectural Testing, Inc. Reports 02-31919.01 and 02-31917.01). This statement is in compliance with CPSC 16 CFR Sec- tion 1201.5 “Certification and labeling requirements” which refers to 15 U.S. Code (USC) 2063 stating “…Such certificate shall accompany the product or shall otherwise be furnished to any distributor or retailer to whom the product is delivered.” Some local building codes require the use of tempered glass with permanent marking in such locations. Glass meeting this requirement is available from the factory. Please contact your dealer or distributor to order. C. BTU Specifications This product is listed to ANSI standards for “Vented Gas Fireplace Heaters” and applicable sections of “Gas Burn- ing Heating Appliances for Manufactured Homes and Recreational Vehicles”, and “Gas Fired Appliances for Use at High Altitudes”. A. Appliance Certification NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE. This appliance is tested and approved as either supplemen- tal room heat or as a decorative appliance. It should not be factored as primary heat in residential heating calculations. NOTICE: This installation must conform with local codes. In the absence of local codes you must comply with the National Fuel Gas Code, ANSI Z223.1-latest edition in the U.S.A. and the CAN/CGA B149 Installation Codes in Canada. 1 Product Specific and Important Safety Information D. High Altitude Installations NOTICE: If the heating value of the gas has been reduced, these rules do not apply. Check with your local gas utility or authorities having jurisdiction. When installing above 2000 feet elevation: • In the USA: Reduce input rate 4% for each 1000 feet above 2000 feet. • In CANADA: Input ratings are certified without a reduction of input rate for elevations up to 4500 feet (1370 m) above sea level. Please consult provincial and/or local authorities having jurisdiction for installations at elevations above 4500 feet (1370 m). Check with your local gas utility to determine proper orifice size. MODELS: COSMO42-IFT, COSMO32-IFT LABORATORY: Underwriters Laboratories, Inc. (UL) TYPE: Direct Vent Heater STANDARD: ANSI Z21.88-2014 • CSA 2.33-2014 Models (U.S. or Canada) Maximum Input BTU/h Minimum Input BTU/h Orifice Size (DMS) COSMO42-IFT (NG)(0-2000 FT)25,250 17,500 #42 COSMO42-IFT (PROPANE)(0-2000 FT 23,500 17,500 .057 COSMO32-IFT (NG)(0-2000 FT)19,000 13,250 #45 COSMO32-IFT (PROPANE)(0-2000 FT)16,500 12,750 1.25 mm 01/29/2018 5Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17 E. Non-Combustible Materials Specification Material which will not ignite and burn. Such materials are those consisting entirely of steel, iron, brick, tile, concrete, slate, glass or plasters, or any combination thereof. Materials that are reported as passing ASTM E 136, Standard Test Method for Behavior of Materials in a Vertical Tube Furnace at 750 ºC shall be considered non-combustible materials. F. Combustible Materials Specification Materials made of or surfaced with wood, compressed pa- per, plant fibers, plastics, or other material that can ignite and burn, whether flame proofed or not, or plastered or unplastered shall be considered combustible materials. G. Electrical Codes NOTICE: This appliance must be electrically wired and grounded in accordance with local codes or, in the absence of local codes, with National Electric Code ANSI/NFPA 70-latest edition or the Canadian Electric Code CSA C22.1. • A 110-120 VAC circuit for this product must be pro- tected with ground-fault circuit-interrupter protection, in compliance with the applicable electrical codes, when it is installed in locations such as in bathrooms or near sinks. 01/29/2018 Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/176 H. Requirements for the Commonwealth of Massachusetts For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, in- cluding but not limited to decks and porches, the following requirements shall be satisfied: Installation of Carbon Monoxide Detectors At the time of installation of the side wall horizontal vented gas fueled equipment, the installing plumber or gas fitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is installed on the floor level where the gas equipment is to be installed. In addi- tion, the installing plumber or gas fitter shall observe that a battery operated or hard wired carbon monoxide detec- tor with an alarm is installed on each additional level of the dwelling, building or structure served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of qualified licensed professionals for the installation of hard wired carbon monoxide detectors. In the event that the side wall horizontally vented gas fu- eled equipment is installed in a crawl space or an attic, the hard wired carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level. In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of thirty (30) days to comply with the above requirements; provided, however, that dur- ing said thirty (30) day period, a battery operated carbon monoxide detector with an alarm shall be installed. Approved Carbon Monoxide Detectors Each carbon monoxide detector as required in accor- dance with the above provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified. Signage A metal or plastic identification plate shall be permanent- ly mounted to the exterior of the building at a minimum height of eight (8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fu- eled heating appliance or equipment. The sign shall read, in print size no less than one-half (1/2) in. in size, “GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OB- STRUCTIONS”. Inspection The state or local gas inspector of the side wall horizon- tally vented gas fueled equipment shall not approve the installation unless, upon inspection, the inspector ob- serves carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5.08(2)(a)1 through 4. Exemptions The following equipment is exempt from 248 CMR 5.08(2) (a)1 through 4: • The equipment listed in Chapter 10 entitled “Equipment Not Required To Be Vented” in the most current edition of NFPA 54 as adopted by the Board; and • Product Approved side wall horizontally vented gas fu- eled equipment installed in a room or structure separate from the dwelling, building or structure used in whole or in part for residential purposes. MANUFACTURER REQUIREMENTS Gas Equipment Venting System Provided When the manufacturer of Product Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the instructions provided by the manufacturer for installation of the equipment and the venting system shall include: • Detailed instructions for the installation of the venting system design or the venting system components; and • A complete parts list for the venting system design or venting system. Gas Equipment Venting System NOT Provided When the manufacturer of a Product Approved side wall horizontally vented gas fueled equipment does not pro- vide the parts for venting the flue gases, but identifies “special venting systems”, the following requirements shall be satisfied by the manufacturer: • The referenced “special venting system” instructions shall be included with the appliance or equipment in- stallation instructions; and • The “special venting systems” shall be Product Ap- proved by the Board, and the instructions for that sys- tem shall include a parts list and detailed installation instructions. A copy of all installation instructions for all Product Ap- proved side wall horizontally vented gas fueled equip- ment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation. See Gas Connection section for additional Common- wealth of Massachusetts requirements. Note: The following requirements reference various Massachusetts and national codes not contained in this document. 01/29/2018 7Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17 2 Getting Started A. Design and Installation Considerations Heat & Glo direct vent gas appliances are designed to operate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside. No additional outside air source is required. Installation MUST comply with local, regional, state and national codes and regulations. Consult insurance carrier, local building inspector, fire officials or authorities having jurisdiction over restrictions, installation inspection and permits. Before installing, determine the following: • Where the appliance is to be installed. • The vent system configuration to be used. • Gas supply piping requirements. • Provisions for optional heat management system. • Electrical wiring requirements. • Framing and finishing details. • Whether optional accessories—devices such as a fan, wall switch, LED lighting or remote control—are desired. C. Tools and Supplies Needed Before beginning the installation be sure that the following tools and building supplies are available. Tape measure Framing material Pliers Hammer Phillips screwdriver Manometer Gloves Framing square Voltmeter Flat blade screwdriver Plumb line Safety glasses Level Reciprocating saw Electric drill and bits: (1/4 in./Phillips #2) Non-corrosive leak check solution 1/2 - 3/4 in. length, #6 or #8 Self-drilling screws Caulking material (300 ºF minimum continuous exposure rating) Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. For assistance or additional information, consult a qualified service technician, service agency or your dealer. Figure 2.1 Good Faith Wall Surface Temperatures Above Appliance B. Good Faith Wall Surface MEASUREMENTS FROMTOP EDGE OF THE OPENING 6 in. 18 in. 24 in. 30 in. 36 in. 48 in. TO CEILING 42 in. 12 in.194°F APPLIANCE FRONT FIREPLACE OPENING 142°F 119°F 110°F 105°F 101°F 98°F 95°F Installation and service of this appliance should be performed by qualified personnel. Hearth & Home Technologies recommends HHT Factory Trained or NFI certified professionals. NOTICE: Temperatures listed above are taken with a temperature measuring probe as prescribed by the test standard used for appliance certification. Temperatures on walls or mantels taken with an infrared thermometer may yield increased temperatures of up to 30 degrees or more depending on the thermometer settings and material characteristics being measured. Use appropriate finishing materials that are able to withstand these conditions. For additional finishing guidelines, see Section 10. If installing a television (TV) above the appliance, see Section 3 of the appliance Owner’s Manual. 01/29/2018 Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/178 D. Inspect Appliance and Components • Carefully remove the appliance and components from the packaging. • The vent system components and decorative fronts may be shipped in separate packages. • If packaged separately, the log set and appliance grate must be installed. • Report to your dealer any parts damaged in shipment, particularly the condition of the glass. • Read all of the instructions before starting the instal- lation. Follow these instructions carefully during the installation to ensure maximum safety and benefit. WARNING! Risk of Fire or Explosion! Damaged parts could impair safe operation. DO NOT install damaged, in- complete or substitute components. Keep appliance dry. Hearth & Home Technologies disclaims any responsibility for, and the warranty will be voided by, the following actions: • Installation and use of any damaged appliance or vent system component. • Modification of the appliance or vent system. • Installation other than as instructed by Hearth & Home Technologies. • Improper positioning of the gas logs or the glass door. • Installation and/or use of any component part not approved by Hearth & Home Technologies. Any such action may cause a fire hazard. WARNING! Risk of Fire, Explosion or Electric Shock! DO NOT use this appliance if any part has been under water. Call a qualified service technician to inspect the appliance and to replace any part of the control system and/or gas control which has been under water. 01/29/2018 9Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17 3 Framing and Clearances Appliance Dimensions Table A. Appliance/Decorative Front Dimension Diagrams Dimensions are actual appliance dimensions. Use for reference only. For framing dimensions and clearances refer to Section 5. Figure 3.1 Appliance Dimensions - COSMO32-IFT O Q P F G H T C X B A E S UØ V W TOP VIEW LEFT VIEW FRONT VIEW RIGHT VIEW ELECTRICAL ACCESS GAS LINE ACCESS D MR L N Ø J K I HEAT MANAGEMENT SYSTEMS ACCESS (BOTH SIDES) Location Inches Millimeters M 16-3/4 425 N 6-5/8 168 O 34-3/8 873 P 2-3/16 56 Q 6 152 R 17-1/4 438 S 25-7/8 657 T 38-1/2 978 U 5 127 V 14 356 W 10-5/8 270 X 7-3/4 197 Location Inches Millimeters A 36 914 B 31 787 C 27-1/4 692 D 15-1/4 387 E 38-1/16 967 F 3-1/2 89 G 7 178 H 41 1041 I 9-13/16 249 J 17-3/4 451 K 1/2 13 L 25-3/4 654 01/29/2018 Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/1710 Figure 3.2 Appliance Dimensions - COSMO42-IFT Location Inches Millimeters M 16-3/4 425 N 6-5/8 168 O 32-3/8 822 P 2-3/16 56 Q 6 152 R 17-1/4 438 S 25-7/8 657 T 50-1/2 1283 U 5 127 V 14 356 W 10-5/8 270 X 7-3/4 197 Location Inches Millimeters A 48 1219 B 43 1092 C 39-1/16 993 D 15-1/4 387 E 33-11/16 856 F 3-1/2 89 G 7 178 H 47-1/16 1195 I 9-13/16 249 J 17-3/4 451 K 1/2 13 L 37-3/4 959 Appliance Dimensions Table O GAS LINE ACCESS ELECTRICAL ACCESS Q LEFT VIEW P C S FRONT VIEW A B T D E G RIGHT VIEW F H I J K NØ MR L UØ V W TOP VIEW X HEAT MANAGEMENT SYSTEMS ACCESS (BOTH SIDES) 01/29/2018 Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/1710 Figure 3.2 Appliance Dimensions - COSMO42-IFT Location Inches Millimeters M 16-3/4 425 N 6-5/8 168 O 32-3/8 822 P 2-3/16 56 Q 6 152 R 17-1/4 438 S 25-7/8 657 T 50-1/2 1283 U 5 127 V 14 356 W 10-5/8 270 X 7-3/4 197 Location Inches Millimeters A 48 1219 B 43 1092 C 39-1/16 993 D 15-1/4 387 E 33-11/16 856 F 3-1/2 89 G 7 178 H 47-1/16 1195 I 9-13/16 249 J 17-3/4 451 K 1/2 13 L 37-3/4 959 Appliance Dimensions Table O GAS LINE ACCESS ELECTRICAL ACCESS Q LEFT VIEW P C S FRONT VIEW A B T D E G RIGHT VIEW F H I J K NØ MR L UØ V W TOP VIEW X HEAT MANAGEMENT SYSTEMS ACCESS (BOTH SIDES) 01/29/2018 11Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17 CFT DECORATIVE FRONTS A B C D E F G COSMO32-IFT CFT-32 in.28-3/16 14-1/8 33-1/8 6-7/8 9-13/16 19-7/8 26-7/8 mm 716 359 841 175 249 505 683 COSMO42-IFT CFT-42 in.40-3/16 14-1/8 45-1/8 6-7/8 9-13/16 19-7/8 26-7/8 mm 1021 359 1146 175 249 505 683 D G E C B A F Dimensions are actual decorative front dimensions. Use for reference only. Figure 3.3 Decorative Front Dimensions - CFT 01/29/2018 Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/1712 G E D C F A B A B C D E F G COSMO32-IFT MAR-COSMO32 in.28-1/4 14-7/8 34-3/16 6-5/16 9-3/8 20-3/4 27-1/8 mm 718 377 867 160 239 527 689 COSMO42-IFT MAR-COSMO42 in.40-1/4 14-7/8 46-3/16 6-5/16 9-5/16 20-3/4 27-1/16 mm 1023 377 1172 160 237 527 688 MARTINI DECORATIVE FRONTS Figure 3.4 Decorative Front Dimensions - MARTINI 01/29/2018 13Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17 B. Clearances to Combustibles When selecting a location for the appliance it is important to consider the required clearances to walls (see Figure 3.5). WARNING! Risk of Fire or Burns! Provide adequate clearance around air openings and for service access. Due to high temperatures, the appliance should be lo- cated out of traffic and away from furniture and draperies. NOTICE: Illustrations reflect typical installations and are FOR DESIGN PURPOSES ONLY. Illustrations/diagrams are not drawn to scale. Actual installation may vary due to individual design preference. Figure 3.5 Appliance Locations 1/2 IN. A E A C TOP VENT ONE 900 ELBOW ALCOVE INSTALLATION D* TOP VENT ONE 90° ELBOW B F Refer to Section 10.C for mantel and wall projection information. Consider the mantel or cabinet system to be installed and comply with the necessary requirements for elevated hearth. Refer to instructions included with cabinet system. A B C D E F COSMO32-IFT Inches 44-5/8 37-5/8 63-1/8 See Section 10.C for Alcove Installation. 15-1/16 17-1/4 Millimeters 1134 956 1603 383 438 COSMO42-IFT Inches 50-1/2 49 71-1/2 19-1/2 17-1/4 Millimeters 1283 1245 1816 495 438 01/29/2018 Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/1714 * Adjust framing dimensions for interior sheathing (such as sheetrock) A B C D HEADER: TWO 2 X 4’S OR 2 X 6’S INSTALLED ON END KING STUD JACK (TRIMMER) STUD MINIMUM FRAMING DIMENSIONS* Models A B C D E F G H I J Rough Opening (Vent Pipe) Rough Opening (Height) Rough Opening (Depth) Rough Opening (Width) Clearance to Ceiling Combustible Floor Combustible Flooring Behind Appliance Sides of Appliance Front of Appliance COSMO32-IFT in.8-5/8 36-1/2 17-3/4 37 31 0 0 1/2 1/2 36 mm 219 927 451 940 787 0 0 13 13 914 COSMO42-IFT in.8-5/8 32-3/4 17-3/4 49 31 0 0 1/2 1/2 36 mm 219 832 451 1245 787 0 0 13 13 914 Figure 3.6 Clearances to Combustibles F J G I H E MEASURE FROM TOP OF APPLIANCE OPENING Framing This appliance is designed to be recessed into combus- tible framing with non-combustible material pre-installed on top and side. Drywall or combustible materials (mini- mum 1/2 inch thick) are designed to contact the non- combustible material/appliance as called out in Section 10 Finishing. This appliance has been thoroughly tested to minimize drywall cracking and/or the protrusion of screws “screw pops" when framed as shown below. Framing should be done in a manner similar to framing a window or door: Double-2x4/2x6 as a header for horizon- tal strength and utilizing Jack or Trimmer stud fastened to the King studs for vertical strength. If elevating the appliance, the base of the unit should also be constructed in a similar manner to prevent settling. Note: Refer to Section 10 for important information related to facing, drywall specifications and decorative front information. 01/29/2018 15Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17 C. Constructing the Appliance Chase A chase is a vertical box-like structure built to enclose the gas appliance and/or its vent system. In cooler climates the vent should be enclosed inside the chase. NOTICE: Treatment of ceiling firestops and wall shield firestops and construction of the chase may vary with the type of building. These instructions are not substitutes for the requirements of local building codes. Therefore, you MUST check local building codes to determine the requirements to these steps. Chases should be constructed and insulated in the same manner as the thermal envelope of the home based on the code requirements for that climate zone to prevent air leakage and draft problems. The chase is an extension of the building thermal envelope. To further prevent drafts and air leakage, the wall shield and ceiling firestops should be caulked with caulk with a minimum of 300 ºF continuous exposure rating to seal gaps. Gas line holes and other openings should be caulked with caulk with a minimum of 300 ºF continu- ous exposure rating or stuffed with unfaced insulation. If the appliance is being installed on a cement surface, a layer of plywood may be placed underneath to prevent conducting cold up into the room. NOTICE: Install appliance on hard metal or wood surfaces extending full width and depth. DO NOT install directly on carpeting, vinyl, tile or any combustible material other than wood. WARNING! Risk of Fire! Maintain specified air space clearances to appliance and vent pipe: • Insulation and other materials must be secured to prevent accidental contact. • The chase must be properly blocked to prevent blown insulation or other combustibles from entering and making contact with fireplace or chimney. • Failure to maintain airspace may cause overheating and a fire. 01/29/2018 Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/1716 A. Vent Termination Minimum Clearances Roof Pitch H (Min.) Ft. Flat to 6/12...........................................................1.0* Over 6/12 to 7/12 .................................................1.25* Over 7/12 to 8/12 .................................................1.5* Over 8/12 to 9/12 .................................................2.0* Over 9/12 to 10/12 ...............................................2.5* Over 10/12 to 11/12 .............................................3.25 Over 11/12 to 12/12 .............................................4.0 Over 12/12 to 14/12 .............................................5.0 Over 14/12 to 16/12 .............................................6.0 Over 16/12 to 18/12 .............................................7.0 Over 18/12 to 20/12 .............................................7.5 Over 20/12 to 21/12 .............................................8.0 Figure 4.1 Minimum Height From Roof to Lowest Discharge Opening HORIZONTALOVERHANG VERTICALWALL GAS DIRECT VENT TERMINATION CAP 12 X ROOF PITCHIS X/ 12 LOWEST DISCHARGE OPENING 2 FT.MIN.20 INCHES MIN. H (MIN.) - MINIMUM HEIGHT FROM ROOF TO LOWEST DISCHARGE OPENING 4 Termination Location and Vent Information Fire Risk. Maintain vent clearance to combustibles as specified. • DO NOT pack air space with insulation or other materials. Failure to keep insulation or other materials away from vent pipe could cause overheating and fire. WARNING Figure 4.2 Staggered Termination Caps Gas, Wood or Fuel Oil Termination Cap B Gas Termination Cap ** A * *If using decorative cap cover(s), this distance may need to be increased. Refer to the installation instructions supplied with the decorative cap cover. ** A B 6 in. (minimum) up to 20 in. 152 mm/508 mm 18 in. minimum 457 mm 20 in. and over 0 in. minimum In a staggered installation with both gas and wood or fuel oil terminations, the wood or fuel oil termination cap must be higher than the gas termination cap. * H minimum may vary depending on regional snowfall. Refer to local codes. 01/29/2018 17Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17 Figure 4.3 Minimum Clearances for Termination O N P R Q X = AIR SUPPLY INLET V = VENT TERMINAL = AREA WHERE TERMINAL IS NOT PERMITTED C J B D B F B A EV V VV V V M H or i V G X V H A V V H Electrical Service V KV K V L C V QMIN RMAX 1 cap 3 feet 2 x Q ACTUAL 2 caps 6 feet 1 x Q ACTUAL 3 caps 9 feet 2/3 x Q ACTUAL 4 caps 12 feet 1/2 x Q ACTUAL QMIN = # termination caps x 3 RMAX = (2 / # termination caps) x QACTUAL Covered Alcove Applications (Spaces open only on one side and with an overhang) Measure horizontal clearances from this surface. Measure vertical clearances from this surface. CLEARANCE = 6 IN. B. Chimney Diagram M = 18 inches ....................clearance under veranda, porch, deck, balcony or overhang 42 inches ................vinyl or composite overhangPermitted when veranda, porch, deck or balcony is fully open on a minimum of 2 sides beneath the floor. K = 6 inches................. clearance from sides of electrical service L = 12 inches................ clearance above electrical service Location of the vent termination must not interfere with access to the electrical service. N = 6 inches ...........non-vinyl sidewalls 12 inches .........vinyl sidewalls O = 18 inches .........non-vinyl soffit and overhang 42 inches .........vinyl soffit and overhang P = 8 ft. CAUTION! Risk of Burns! Termination caps are HOT, consider proximity to doors, traffic areas or where people may pass or gather (sidewalk, deck, patio, etc.). Listed cap shields available. Contact your dealer. • Local codes or regulations may require different clearances. • Vent system termination is NOT permitted in screened porches. • Vent system termination is permitted in porch areas with two or more sides open. • Hearth & Home Technologies assumes no responsibility for the improper performance of the appliance when the venting system does not meet these requirements. • Vinyl protection kits are suggested for use with vinyl siding. A = 12 inches.................clearances above grade, veranda, porch, deck or balcony B = 9 inches (U.S.A.) 12 inches (Canada). clearance to window or door that may be opened, or to permanently closed window C = 18 inches.................clearance below unventilated soffit 18 inches.................clearance below ventilated soffit 30 inches .................clearance below vinyl soffits and electrical service D = 6 inches...................clearance to outside corner E = 6 inches...................clearance to inside corner F = 3 ft. (Canada) ..........not to be installed above a gas me-ter/regulator assembly within 3 feet horizontally from the center-line of the regulator G = 3 ft ...........................clearance to gas service regulator vent outlet H = 12 inches.................clearance to non-mechanical (unpow- ered) air supply inlet, combustion air inlet or direct-vent termination i = 3 ft. (U.S.A.) 6 ft. (Canada) ...........clearance to a mechanical (powered) air supply inlet All mechanical air intakes within 10 feet of a termination cap must be a minimum of 3 feet below termination.J = 7 ft. ......................... On public property: clearance above paved sidewalk or a paved driveway. A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings. 01/29/2018 Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/1718 C. Approved Pipe Approved Pipe - Rigid This appliance is approved for use with Hearth & Home Technologies SLP venting systems. Refer to Section 12.A for vent component information and dimensions. DO NOT mix pipe, fittings or joining methods from differ- ent manufacturers. The pipe is tested to be run inside an enclosed wall. There is no requirement for inspection openings at each joint within the wall. WARNING! Risk of Fire or Asphyxiation. This appli- ance requires a separate vent. DO NOT vent to a pipe serving a separate solid fuel burning appliance. Approved Pipe - Flex This appliance is approved for use with Hearth & Home Technologies SLP-FLEX (6-5/8 inch) and SLP-FLEX7 (7 inch) venting systems. DO NOT mix pipe, fittings or joining methods from different manufacturers. SLP-FLEX and SLP-FLEX7 venting cannot be interchanged. SLP-FLEX (6-5/8 Inch): Venting may be used in any venting configuration shown in the venting tables pro- vided that the horizontal vent length is reduced by 25%. SLP-FLEX7 (7 Inch-Canada Only): Venting requires adapter collars to transition from the 6-5/8 IN. appliance starting collar and to the 6-5/8 IN. termination cap. Refer to installation instructions included with the SLP-FLEX7 collar adapter (SLP-FLEX7-AM/SLP-FLEX7-A). SLP- FLEX7 Series venting is approved for use in Canada only. The pipe is tested to be run inside an enclosed wall. There is no requirement for inspection openings at each joint within the wall. WARNING! Risk of Fire or Asphyxiation. This appli- ance requires a separate vent. DO NOT vent to a pipe serving a separate solid fuel burning appliance. 01/29/2018 19Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17 D. Use of Elbows Diagonal runs have both vertical and horizontal vent as- pects when calculating the effects. Use the rise for the vertical aspect and the run for the horizontal aspect. See Figure 4.4. Two 45º elbows may be used in place of one 90º elbow. On 45º runs, one foot of diagonal is equal to 8-1/2 in. (216 mm) horizontal run and 8-1/2 in. (216 mm) vertical run. A length of straight pipe is allowed between two 45º elbows. See Figure 4.4. Figure 4.5 shows the vertical and horizontal offsets for SLP elbows. Figure 4.4 HORIZONTAL VERTICAL RUN RISEEFFECTIVELENGTHY X X X Vent Type X Inches Millimeters SLP 11-1/4 286 Figure 4.5 Vertical and Horizontal Offset for SLP Elbows Vent Type X Y Inches Millimeters Inches Millimeters SLP 5 127 11-3/4 298 SLP Pipe Effective Length Rise/Run Inches Millimeters Inches Millimeters SLP4 4 102 2-3/4 70 SLP6 6 152 4-1/4 108 SLP12 12 305 8-1/2 216 SLP24 24 610 17 432 SLP36 36 914 25-1/2 648 SLP48 48 1219 34 864 SLP6A 3 to 6 76 to 152 2-1/8-4-1/4 54-108 SLP12A 3 to 12 76 to 305 2-1/8-8-1/2 54-216 01/29/2018 Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/1720 E. Measuring Standards Vertical and horizontal measurements listed in the vent diagrams were made using the following standards: • Pipe measurements are shown using the effective length of pipe. See Section 12.A (Figure 12.1) for information on effective length of pipe components. • Horizontal terminations are measured to the outside mounting surface (flange of termination cap). See Figure 4.6. • Vertical terminations are measured to top of last section of pipe. See Figure 4.7. • Horizontal pipe installed level with no rise. MEASURE TO SHADED SURFACE (OUTSIDE MOUNTING SURFACE) Figure 4.6 Measure to Outside Mounting Surface Figure 4.7 Measure to Top of Last Section of Pipe 01/29/2018 21Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17 G. Vent Diagrams Figure 4.9 Vent Cap F. Use of Flex Vent (SLP-FLEX Series 6-5/8 Inch) The flex vent must be supported with the spacing between support intervals not exceeding 4 feet, with no more than 1/2 inch sag between supports. A support is required at each change in venting direction, and in any location where it is necessary to maintain the necessary clearance to combustibles. A simple “up and out” installation (Figure 4.8) requires only enough support to maintain the necessary clearance to combustibles. However, the vent attachment point and the firestop loca- tion are considered to be supports. Figure 4.8 Flex Vent Pipe - Generic Fireplace Shown 3 in. CLEARANCE TERMINATIONCAP FLEX-VENT 1 in. CLEARANCE General Rules: • Elbows may be placed back to back anywhere in the system. • Any 90º elbow may be replaced with two back to back 45º elbows. • When penetrating a combustible wall, a wall shield firestop must be installed. • When penetrating a combustible ceiling, a ceiling firestop must be installed. • Horizontal runs of vent do not require vertical rise; horizontal runs may be level. • Horizontal termination cap should have a 1/4 inch downward slant to allow any moisture in cap to be released. See Figure 4.9. 1/4 in. max. (6 mm) 01/29/2018 Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/1722 Top Vent - Horizontal Termination Figure 4.10 Note: Use SLP Series components only. Note: There MUST be a 25% reduction in total H when using SLP-FLEX Series (6-5/8 inch) vent except when using the simple up and out installation. See Figure 4.8. One 90º Elbow Risk of Fire! When using SLP-TB1 termination cap on top vented fireplaces, a three foot minimum vertical vent section is required before installing first elbow. H1 V1 WARNING * V Minimum*H1 Maximum COSMO42-IFT COSMO32-IFT 90° Elbow Not Allowed 1 ft.305 mm 1 ft.305 mm 1 ft.305 mm 2 ft.610 mm 2 ft.610 mm 3 ft.914 mm 4 ft.1.2 m 3 ft.914 mm 5 ft.1.5 m 6 ft.1.8 m 4 ft.1.2 m 7 ft.2.1 m 15 ft.4.6 m 5 ft.1.5 14 ft.4.3 m H MAX. =14 ft. (4.3 m) V + H MAX. = 40 ft. (12.2 m) H MAX. =15 ft. (4.6 m) V + H MAX. = 40 ft. (12.2 m) CAUTION: The SLP-HRC-SS termination caps are not approved for use with these models. May lead to elevated glass temperature that may cause tempered glass breakage. 01/29/2018 23Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17 Top Vent - Horizontal Termination - (continued) Two Elbows Figure 4.11 Note: Use SLP Series components only. INSTALLED HORIZONTALLY H1 H2 V1 WARNING * V Minimum*H1 Maximum COSMO42-IFT COSMO32-IFT 90° Elbow Not Allowed 1 ft.305 mm 1 ft.305 mm 1-1/2 ft.457 mm 2 ft.610 mm 2 ft.610 mm 2 ft.610 mm 4 ft.1.2 m 3 ft.914 mm 4 ft.1.2 m 6 ft.1.8 m 4 ft.1.2 m 6 ft.1.8 m 15 ft.4.6 m 5 ft.1.5 15 ft.4.6 m H1 + H2 MAX. =15 ft. (4.6 m) V1 + H1 + H2 MAX. = 40 ft. (12.2 m) CAUTION: The SLP-HRC-SS termination caps are not approved for use with these models. May lead to elevated glass temperature that may cause tempered glass breakage. Note: There MUST be a 25% reduction in total H when using SLP-FLEX Series (6-5/8 inch) vent except when using the simple up and out installation. See Figure 4.8. Risk of Fire! When using SLP-TB1 termination cap on top vented fireplaces, a three foot minimum vertical vent section is required before installing first elbow. 01/29/2018 Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/1724 H2 H1 V2 V1 Figure 4.12 Top Vent - Horizontal Termination - (continued) Three Elbows COSMO32-IFT V1 Minimum H1 + H2 Maximum V2 V1 + V2 Minimum 90° Elbow 6 ft.1.8 m ** 1 ft.305 mm 10 ft.3.0 m ** 2 ft.610 mm 12 ft.3.7 m ** 3 ft.914 mm 14 ft.4.3 m ** H1 + H2 MAX. =14 ft. (4.3 m) V1 + V2 + H1 + H2 MAX. = 40 ft. (12.2 m) *No specific restrictions on this value EXCEPT V1 + V2 + H1 + H2 cannot exceed 40 ft. (12.2 m) CAUTION: The SLP-HRC-SS termination caps are not approved for use with these models. May lead to elevated glass temperature that may cause tempered glass breakage. COSMO42-IFT V1 Minimum H1 + H2 Maximum V2 V1 + V2 Minimum 1 ft.305 mm 10 ft.3.0 m ** 2 ft.610 mm 12 ft.3.7 m ** 3 ft.914 mm 14 ft.4.3 m ** H1 + H2 MAX. =14 ft. (4.3 m) V1 + V2 + H1 + H2 MAX. = 40 ft. (12.2 m) *No specific restrictions on this value EXCEPT V1 + V2 + H1 + H2 cannot exceed 40 ft. (12.2 m) Note: There MUST be a 25% reduction in total H when using SLP-FLEX Series (6-5/8 inch) vent except when using the simple up and out installation. See Figure 4.8. 01/29/2018 25Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17 Note: Use SLP Series components only. V1 H1 H3 H2 INSTALLED HORIZONTALLY INSTALLED HORIZONTALLY V Minimum H1 + H2 + H3 MAXIMUM COSMO42-IFT (NG ONLY) 4 ft.1.2 m 15 ft.4.6 m H1 + H2 + H3 MAX. = 15 ft. (4.6 m) V1 MAX. = 7 ft (2.1 m) Top Vent - Horizontal Termination - (continued) Risk of Fire! This vent configuration can ONLY be used for COSMO42-IFT Natural Gas appliances. WARNING CAUTION: The SLP-HRC-SS termination caps are not approved for use with these models. May lead to elevated glass temperature that may cause tempered glass breakage. Figure 4.13 Three Elbows Note: There MUST be a 25% reduction in total H when using SLP-FLEX Series (6-5/8 inch) vent except when using the simple up and out installation. See Figure 4.8. 01/29/2018 Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/1726 Top Vent - Vertical Termination No Elbow Figure 4.14 V1 = 60 ft. Max. (18.3 m) Note: Use SLP Series components only. Note: If installing a vertical vent/termination off the top of the appliance, the optional vertical termination baffle may be needed. V1 01/29/2018 27Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17 Figure 4.15 Installing Restrictor Exhaust Restrictor Instructions Exhaust restrictors are recommended for these verti- cally terminated products which have excessive draft. Exhaust restrictors will compensate for high draft, and restore visual flame height. If the vent configuration has a total vertical of 15-60 feet, an exhaust restrictor may be needed. The exhaust restrictor can be located in the appliance manual bag. Exhaust Restrictor Installation 1. COSMO42-IFT Only: Remove inner heat shield by removing two wing nuts from top front of heat shield and two screws that secure the heat shield to back wall of fireplace. Retain heat shield and fasteners. 2. COSMO32-IFT/COSMO42-IFT: Center the exhaust restrictor in the open end of the exhaust outlet and secure through the slots on the exhaust restrictor with the two 1/4 in. self-tapping screws provided in the appliance manual bag. See Figure 4.15. 3. COSMO42-IFT Only: Reinstall shield by securing it with the two wing nuts and two screws previously re- moved in Step 1. SCREWS WING NUTS HEAT SHIELD EXHAUST RESTRICTOR INSTALLED SCREWS 01/29/2018 Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/1728 Figure 4.16 Two 90º Elbows Note: Use SLP Series components only. Top Vent - Vertical Termination - (continued) H1 V1 V2 COSMO32-IFT V1 Minimum H Maximum V2 V1 + V2 Minimum 90° Elbow 2 ft.610 mm ** 1 ft.305 mm 3 ft.914 mm ** 2 ft.610 mm 5 ft.1.5 m ** 3 ft.914 mm 7 ft.2.1 m ** 4 ft.1.2 m 15 ft.4.6 m ** H MAX. =15 ft. (4.6 m) V1 + V2 + H MAX. = 40 ft. (12.2 m) * No specific restrictions on this value EXCEPT V1 + V2 + H cannot exceed 40 ft. (12.2 m) COSMO42-IFT V1 Minimum H Maximum V2 V1 + V2 Minimum 1 ft.305 mm 2 ft.610 mm ** 2 ft.610 mm 3 ft.914 mm ** 3 ft.914 mm 5 ft.1.5 m ** 4 ft.1.2 m 7 ft.2.1 m ** 5 ft.1.5 m 15 ft.4.6 m ** H MAX. =15 ft. (4.6 m) V1 + V2 + H MAX. = 40 ft. (12.2 m) * No specific restrictions on this value EXCEPT V1 + V2 + H cannot exceed 40 ft. (12.2 m) Note: There MUST be a 25% reduction in total H when using SLP-FLEX Series (6-5/8 inch) vent except when using the simple up and out installation. See Figure 4.8. 01/29/2018 29Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17 Figure 4.17 Three 90º Elbows Top Vent - Vertical Termination - (continued) INSTALLED HORIZONTALLY H1 H2 V1 V2 Note: Use SLP Series components only. COSMO32-IFT V1 Minimum H1 + H2 Maximum V2 V1 + V2 Minimum 90° Elbow 1 ft.305 mm ** 1 ft.305 mm 2 ft.610 mm ** 2 ft.610 mm 4 ft.1.2 m ** 3 ft.914 mm 6 ft.1.8 m ** 4 ft.1.2 m 14 ft.4.3 m ** H MAX. =14 ft. (4.3 m) V1 + V2 + H1 + H2 MAX. = 40 ft. (12.2 m) * No specific restrictions on this value EXCEPT V1 + V2 + H1 + H2 cannot exceed 40 ft. (12.2 m) COSMO42-IFT V1 Minimum H1 + H2 Maximum V2 V1 + V2 Minimum 1 ft.305 mm 1 ft.305 mm ** 2 ft.610 mm 2 ft.610 mm ** 3 ft.914 mm 4 ft.1.2 m ** 4 ft.1.2 m 6 ft.1.8 m ** 5 ft.1.5 m 14 ft.4.3 m ** H MAX. =14 ft. (4.3 m) V1 + V2 + H1 + H2 MAX. = 40 ft. (12.2 m) * No specific restrictions on this value EXCEPT V1 + V2 + H1 + H2 cannot exceed 40 ft. (12.2 m) Note: There MUST be a 25% reduction in total H when using SLP-FLEX Series (6-5/8 inch) vent except when using the simple up and out installation. See Figure 4.8. 01/29/2018 Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/1730 Note: Use SLP Series components only. COSMO42-IFT & COSMO32-IFT V1 MIN.H1 MAX.V2 MIN.H2 MAX.V3 MIN. 2-1/2 ft.762 mm 4 ft.1.2 m 4 ft.1.2 m 4 ft.1.2 m 3-1/2 ft.1.0 m V1 + V2 + V3 + H1 + H2 Maximum= 40 ft. (12.2 m) V1 H1 V2 V3 H2 Figure 4.18 Four 90º Elbows Top Vent - Vertical Termination - (continued) Note: There MUST be a 25% reduction in total H when using SLP-FLEX Series (6-5/8 inch) vent except when using the simple up and out installation. See Figure 4.8. 01/29/2018 31Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17 EXHAUST VENT PIPEINLET AIR VENT PIPE OUTSIDE FACE OF FIREPLACE TOP OF FIREPLACE OPENING SHADED AREA DEFINED AS “INSIDE EXISTING MASONRY FIREPLACE” 3 IN. (76 mm) MIN. 5 IN. (127 mm) MIN. EXHAUST VENT PIPE Figure 4.20 Existing Fireplace DV-46DVA-GCL Clearance Requirements Clearances to Combustibles: Refer to Section 3 for clearances to the appliance and Section 10 for mantel, mantel legs and wall projection information. Refer to Section 5 for pipe clearances to combustibles. Termination Cap For installation of termination cap see minimum vent heights for various pitched roofs. See Section 4.A. Flue Damper Fully lock the solid fuel fireplace’s flue damper in the open position, OR completely remove it. Venting Components The LINK-DV30B is approved for use with the coaxial/co- linear venting application. The LINK-DV30B kit includes: • Two 30 foot sections of flexible vent pipe (3 inches Ø). One section is used to draw combustion air and the other section is used to expel exhaust gases. • One vertical termination cap. WARNING! Risk of Fire! Coaxial to colinear venting con- figuration may only be used in existing non-combustible chimney. Installation in any other venting application could cause fire. Prior to installing the gas appliance: • Have the chimney and adjacent structure inspected and cleaned by qualified professionals. Hearth & Home Technologies recommends that NFI or CSIA certified professionals, or technicians under the direction of certi- fied professionals, conduct a minimum of a NFPA 211 Level 2 inspection of the chimney. • Replace component parts of the chimney and fireplace as specified by the professionals. • Ensure all joints are properly engaged and the chimney is properly secured. Stainless Steel Flex Requirement - COSMO32-IFT ONLY: The COSMO32-IFT model requires the use of a 3 ft. stain- less steel flex liner (468-380A) to be installed directly to the exhaust collar on the DV-46DVA-GCL connector. Coaxial to Colinear Venting The coaxial to colinear adapter (DV-46DVA-GCL) is ap- proved for installations into solid fuel masonry or factory built fireplaces that have been installed in accordance with the National, Provincial, State and local building codes. The DV-46DVA-GCL must be recessed into exist- ing masonry fireplace. See Table 1 and Figure 4.20. Table 1 CAUTION! DO NOT use any flue restrictor when vent- ing with the DV-46DVA-GCL adapter and LINK-DV30B kit. This could result in poor flame appearance, sooting, pilot malfunction, or overheating. Figure 4.19 Coaxial/Colinear Appliance Adapter (DV-46DVA-GCL) CLEARANCE TO COMBUSTIBLES REQUIREMENTS DV-46DVA-GCL 3 in. (76 mm) Exhaust Vent Pipe 5 in (127 mm) WARNING! Risk of Fire! Risk of Asphyxiation! Failure to install the stainless steel flex could cause excessive flex vent temperatures. • Aluminum material degradation could cause flex vent system to fail. • Installer MUST install the 3 ft. stainless steel flex on COSMO32-IFT. 01/29/2018 Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/1732 Figure 4.21 Connecting the DV-46DVA-GCL Adapter to Appliance Top Vent • Remove top seal cap and insulation if equipped. See Section 6, “Appliance Preparation.” Attach the DV-46DVA-GCL adapter to the appliance starting collar with 3-1/2 in. self-tapping screws. See Figure 4.21. Connecting the LINK-DV30B to the DV-46DVA-GCL adapter • Insert the two sections of flexible vent pipe down the existing chimney. • Attach one section of flexible vent pipe to the exhaust collar on top of the DV-46DVA-GCL adapter with three self-tapping screws. • Attach one section of flexible vent pipe to the inlet collar on top of the DV-46DVA-GCL adapter with three self- tapping screws. WARNING! Risk of Fire, Explosion or Asphyxiation! Do NOT connect this gas appliance to a chimney flue serving a separate solid fuel or gas burning appliance. • May impair safe operation of this appliance or other appliances connected to the flue. • Vent this appliance directly outside. • Use separate vent system for this appliance. • To minimize cold air drafts, seal around the flex vents at the damper inside the chimney with non-combustible unfaced fiberglass or rock wool insulation. The DV-46DVA-GCL adapter must be recessed into existing masonry fireplace. This measurement is taken from the top of the fireplace opening. See Table 1 and Figure 4.20. EXISTING CHIMNEY HEARTHFLOOR EXISTING CHIMNEY EXHAUST AIR VENT PIPE INLET AIR VENT PIPE To minimize cold air drafts, seal with non-combustible insulation. TERMINATION CAP DIRECT VENT FIREPLACE V TOP VENT NOTICE: To achieve optimum per- formance of appliance, minimize or avoid bends in exhaust vent pipe. V Minimum 10 ft.3.05 m Maximum 40 ft.12.2 m CAUTION! DO NOT use any flue restric- tor when venting with the DV-46DVA-GCL adapter and LINK-DV30B kit. This may re- sult in poor flame appearance, sooting, pilot malfunction, or overheating. 01/29/2018 33Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17 A. Pipe Clearances to Combustibles WARNING! Risk of Fire! Maintain air space clearance to vent. DO NOT pack insulation or other combustibles: • Between ceiling firestops • Between wall shield firestops • Around vent system Failure to keep insulation or other material away from vent pipe could cause overheating and fire. 5 Vent Clearances and Framing Figure 5.2 Wall Penetration * Shows center of vent framing hole for top or rear venting. The center of the hole is 1 in. (25 mm) above the center of the horizontal vent pipe. Figure 5.1 Horizontal Venting Clearances To Combustible Materials * When using SLP pipe, minimum clearances from the vent pipe to combustible materi- als at inside wall firestops are: Top: 2-1/2 in. (64 mm) Bottom: 1/2 in. (13 mm) Sides: 1 in. (25 mm) Note: Heat shields MUST overlap by a minimum of 1-1/2 in. (38 mm). • If wall thickness is less than 4 in. the existing heat shields must be field trimmed. If wall thickness is greater than 7-1/4 in. a DVP-HSM-B will be required. • SLP heat shield - designed to be used on a wall 4-3/8 in. to 7-5/8 in. (111 mm to 194 mm thick). • If wall thickness is less than 4-3/8 the existing heat shields must be field trimmed. If wall thickness is greater than 7-5/8 in. a DVP-HSM-B will be required. (SLP Pipe Shown) 3 in. (76 mm) top clearance * 1 in. (25 mm) clearance bottom & sides Heat Shield Wall Shield Firestop Heat Shield WALL 3 in. (76 mm) top clearance 1 in. (25 mm) clearance around vertical sections B. Wall Penetration Framing/Firestops Combustible Wall Penetration Whenever a combustible wall is penetrated, you must frame a hole for the wall shield firestop(s). The wall shield firestop maintains minimum clearances and prevents cold air infiltration. • The opening must be framed on all four sides using the same size framing materials as those used in the wall construction. • SLP pipe - A wall shield firestop must be placed on each side of an interior wall. A minimum 1-1/2 in. (38 mm) overlap of attached heat shields must be maintained. • See Section 7.F for information for regarding the instal- lation of a horizontal termination cap. Non-Combustible Wall Penetration If the hole being penetrated is surrounded by non-com- bustible materials such as concrete, a hole with diameter one inch greater than the pipe is acceptable. Whenever a non-combustible wall is penetrated, the wall shield firestop is only required on one side and no heat shield is necessary. A* B COSMO32-IFT 42 in. 41 in. 1067 mm 1041 mm COSMO42-IFT 48-1/16 47-1/16 1221 1195 A 10 in.10 in. B DO NOT PACK WITH INSULATION OR OTHER MATERIAL COSMO32-IFT Shown 01/29/2018 Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/1734 C. Ceiling Firestop/Floor Penetra- tion Framing A ceiling firestop MUST be used between floors and attics. • SLP pipe only - Frame opening 9 in. x 9 in. (229 mm x 229 mm) whenever the vent penetrates a ceiling/floor (see Figure 5.3). • Frame the area with the same sized lumber as used in ceiling/floor joist. • The ceiling firestop may be installed above or below the ceiling joists when installed with an attic insulation shield. It must be under joists between floors that are not insulated. Refer to Figure 5.4. • Secure in place with nails or screws. WARNING! Risk of Fire! DO NOT pack insu- lation around the vent. Insulation must be kept back from the pipe to prevent overheating. Figure 5.3 Installing Ceiling Firestop Figure 5.4 Installing the Attic Shield INSTALL ATTIC INSULATION SHIELDS BEFORE OR AFTER INSTALLATION OF VENT SYSTEM CEILING FIRESTOP INSTALLED BELOW CEILING CEILING FIRESTOP INSTALLED ABOVE CEILING ATTIC ABOVE A PIPE SLP A 9 in. (229 mm) A D. Install Attic Insulation Shield WARNING! Fire Risk. DO NOT allow loose materials or insulation to touch vent. Hearth & Home Technologies requires the use of an attic shield. The International Fuel Gas Code requires an attic shield constructed of 26 gauge minimum steel that extends at least 2 in. (51 mm) above insulation. • Attic insulation shields must meet specified clearances to combustible materials and be secured in place. • An attic insulation shield kit is available from Hearth & Home Technologies. Contact your dealer to order. Install attic insulation shield according to instructions included with kit. 01/29/2018 35Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17 CAUTION! Risk of Cuts, Abrasions or Flying Debris. Wear protective gloves and safety glasses during instal- lation. Sheet metal edges are sharp. NOTICE: Once appliance is set up for top or rear venting, it CANNOT be changed at a later time. A. Vent Collar Preparation 6 Appliance Preparation WARNING! Risk of Fire! Do not remove heat shield. El- evated header temperatures may cause a fire. COSMO42-IFT 1. Remove two screws and discard. See Figure 6.1. 2. Fold up top heat shield to 90 degrees as shown in Figure 6.2. REMOVE SCREWS Figure 6.1 COSMO42-IFT - Shipping Position Figure 6.2 COSMO42-IFT - Top Heat Shield in Position Figure 6.3 COSMO32-IFT - Shipping Support in Shipping Position Figure 6.4 COSMO32-IFT - Shipping Support and Seal Cap Removed COSMO32-IFT 1. Remove two screws and remove shipping support. See Figure 6.3. 2. Remove and discard shipping support, seal cap, and screws. See Figure 6.4. REMOVE 2 SCREWS HEAT MANAGEMENT KNOCKOUT LOCATIONS (RIGHT & LEFT SIDES) TOP HEAT SHIELD IN POSITION 01/29/2018 Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/1736 C. Securing and Leveling the Appliance WARNING! Risk of Fire! Prevent contact with: • Sagging or loose insulation • Insulation backing or plastic • Framing and other combustible materials Block openings into the chase to prevent entry of blown- in insulation. Make sure insulation and other materials are secured. DO NOT notch the framing around the appliance standoffs. Failure to maintain air space clearance could cause overheating and fire. The diagram shows how to properly position and secure the appliance. See Figure 6.5. Nailing tabs are provided to secure the appliance to the framing members. • Bend out nailing tabs on each side. • Place the appliance into position. • Keep nailing tabs flush with the framing. • Level the appliance from side to side and front to back. • Shim the appliance as necessary. It is acceptable to use wood shims underneath the appliance. • Secure the appliance to the framing by using nails or screws through the nailing tabs. • Optional: Secure the appliance to the floor by inserting two screws through the pilot holes at the bottom of the appliance. Figure 6.5 Proper Positioning, Leveling And Securing Of Appliance B. Installing Optional Heat Management Systems NOTICE: Additional clearances are required for heat management systems installations. Provisions must be made in advance to ensure fit within the framing. • Locate the heat management ports on the left and right sides of the appliance. Either one or two Heat-Zone® -Gas Kits may be installed. See Figure 6.2. Remove the knockouts from the appliance with a tin snips. • Center the duct collar around the exposed hole and attach it to the appliance with 3 screws. Note: Do this BEFORE final positioning of the appliance. • Determine the location for the air register/fan housing assembly. Reference the Heat-Zone®-Gas Kit, Smart-Wall™ TV Kit, Heat-Duct Kit or Heat-Out-Gas Kit instructions for the remaining installation steps. The COSMO42-IFT and COSMO32-IFT models ship with factory-installed non-combustible board. This board must be used. Do NOT remove. See Figure 6.5. NAILING TABS BOTH SIDES FACTORY-INSTALLED NON-COMBUSTIBLE BOARD DO NOT REMOVE 01/29/2018 37Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17 WARNING! Risk of Fire! DO NOT remove factory- installed non-combustible material. D. Non-Combustible Material Installation Figure 6.7 Installation of the Side Non-Combustible Components INSTALL TWO OF THE PROVIDED SCREWS INTO THESE PILOT HOLES INSTALL FOUR OF THE PROVIDED SCREWS INTO THESE PILOT HOLES NOTE: BOTH LEFT & RIGHT SIDES Figure 6.6 Shipping Position - Non-Combustible Sides SPLATTER GUARD This model ships with the required top, left and right non- combustible board. The top non-combustible board has been pre-installed at the factory with three screws. The left and right side non-combustible boards are shipped in the cardboard splatter guard in front of the appliance. See Figure 6.6. 1. Remove the left and right non-combustible components from the shipping position and set aside. 2. Remove the lower cover panel by removing two screws located on the lower left and right sides of the appliance opening. Retain screws. Lift the lower cover panel “up” and “out” to remove. 3. Locate the manual bag assembly and remove the small package containing the 1-1/2 inch Phillips screws. Note: Care should be taken when installing screws into the non-combustible board. DO NOT overtighten screws. Screws should be set “flush” to the surface of the non- combustible board. 4. Further secure the top non-combustible board by installing screws into the pilot holes located in the upper left and right corners as shown in Figure 6.7. 5. Install the left and right non-combustible components with four of the provided Phillips screws. See Figure 6.7. 6. Install drywall screws (not provided) around the perimeter of the installed non-combustible components to secure it to the framing material. Refer to Section 10 for more information. 01/29/2018 Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/1738 7 Venting and Chimneys Figure 7.1 High Temperature Silicone Sealant A . Assemble Vent Sections (SLP Only) To attach the first vent component to the starting collars of the appliance: • Lock the vent components into place by sliding the pipe section onto the collar. • Align the seam of the pipe and seam of collar to allow engagement. Rotate the vent component to lock into place. Use this procedure for all vent components. See Figure 7.2. • Slide the gasket over the first vent section and place it flush to the appliance. This will prevent cold air infiltration. Caulk with a minimum of 300 ºF continuous exposure rating may be used to hold the part in place. • Continue adding vent components, locking each succeeding component into place. • Ensure that each succeeding vent component is securely fitted and locked into the preceding component. Required Commercial, Multi-family (Multi-level exceeding two stories), or High-Rise Applications All outer pipe joints must be sealed with high temperature silicone (300 ºF minimum continuous exposure rating), in- cluding the slip section that connects directly to the hori- zontal termination cap. • Apply a bead of silicone sealant (300 ºF minimum con- tinuous exposure rating) to the outside of connecting joint after joining sections. See Figure 7.1. OR Apply aluminum foil tape (300 ºF minimum continuous exposure rating) to the outside of connecting joint after joining sections. On horizontal pipe runs, it is recom- mended that the tape seam is positioned on the bottom side of the vent pipe. • Only outer pipes need to be sealed. All unit collar, pipe, slip section, elbow and cap outer flues shall be sealed in this manner, unless otherwise stated. Figure 7.2 Adding Venting Components WARNING! Risk of Fire or Explosion! DO NOT break silicone seals on slip sections. Use care when remov- ing termination cap from slip pipe. If slip section seals are broken during removal of the termination cap, vent could leak. Note: Align seams to engage pipe, then rotate counterclockwise to lock 01/29/2018 39Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17 B. Assemble Slip Sections • Slide the inner flue of the slip section into the inner flue of the pipe section and the outer flue of the slip section over the outer flue of the pipe section. See Figure 7.3. • Slide together to the desired length. Figure 7.3 Slip Section Pilot Holes Figure 7.4 Screws into Slip Section Pilot hole • Continue adding pipe as necessary following instructions in “Assembling Pipe Sections.” NOTICE: If slip section is too long, the inner and outer flues of the slip section can be cut to the desired length. • Maintain a 1-1/2 in. (38 mm) overlap between the slip section and the pipe section. • Secure the pipe and slip section with two screws no longer than 1/2 in. (13 mm), using the pilot holes in the slip section. See Figure 7.4. 01/29/2018 Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/1740 120º Figure 7.5 Securing Vertical Pipe Sections 120º Figure 7.6 Securing Horizontal Pipe Sections D. Disassemble Vent Sections • Rotate either section (see Figure 7.7) so the seams on both pipe sections are aligned as shown in Figure 7.8. • Pull carefully to separate the pieces of pipe. Figure 7.8 Align and Disassemble Vent Sections Figure 7.7 Rotate Seams for Disassembly C. Secure the Vent Sections • Vertical runs originating off the top of the appliance, with no offsets, must be supported every 8 ft. (2.44 m) after the maximum allowed 25 ft. (7.62 m) of unsupported rise. • Vertical runs originating off the rear of the appliance, or after any elbow, must be supported every 8 ft. (2.44 m). • Horizontal runs must be supported every 5 feet (1.52 m). • Vent supports or plumbers strap (spaced 120º apart) may be used to support vent sections. See Figures 7.5 and 7.6. • Wall shield firestops may be used to provide horizontal support to vent sections. • SLP ceiling firestops have tabs that may be used to provide vertical support. WARNING! Risk of Fire, Explosion or Asphyxiation! Improper support could allow vent to sag and separate. Use vent run supports and connect vent sections per in- stallation instructions. DO NOT allow vent to sag below connection point to appliance. 01/29/2018 41Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17 E. Vertical Termination Requirements Install Metal Roof Flashing • See minimum vent heights for various pitched roofs (Figure 7.9) to determine the length of pipe to extend through the roof. • Slide the roof flashing over the pipe sections extending through the roof as shown in Figure 7.10. Roof Pitch H (Min.) Ft. Flat to 6/12........................................1.0* Over 6/12 to 7/12 ............................1.25* Over 7/12 to 8/12 ..............................1.5* Over 8/12 to 9/12 ..............................2.0* Over 9/12 to 10/12 ............................2.5* Over 10/12 to 11/12 .........................3.25 Over 11/12 to 12/12 ...........................4.0 Over 12/12 to 14/12 ...........................5.0 Over 14/12 to 16/12 ...........................6.0 Over 16/12 to 18/12 ...........................7.0 Over 18/12 to 20/12 ...........................7.5 Over 20/12 to 21/12 ...........................8.0 * H minimum may vary depending on regional snowfall. Refer to local codes. Figure 7.9 Minimum Height From Roof to Lowest Discharge Opening HORIZONTALOVERHANG VERTICALWALL GAS DIRECT VENT TERMINATION CAP 12 X ROOF PITCHIS X/ 12 LOWEST DISCHARGE OPENING 2 FT.MIN.20 INCHES MIN. H (MIN.) - MINIMUM HEIGHT FROM ROOF TO LOWEST DISCHARGE OPENING Figure 7.11 insert Bolt into Brackets NOTICE: Failure to properly caulk the roof flashing and pipe seams could permit entry of water. • Caulk the gap between the roof flashing and the outside diameter of the pipe. • Caulk the perimeter of the flashing where it contacts the roof surface. See Figure 7.10. • Caulk the overlap seam of any exposed pipe sections that are located above the roof line. CAULK Figure 7.10 Assemble and Install Storm Collar CAUTION! Risk of Cuts, Abrasions or Flying Debris. Wear protective gloves and safety glasses during instal- lation. Sheet metal edges are sharp. • Slide the storm collar onto the exposed pipe section and align brackets. • Insert a bolt (provided) through the brackets and install nut. Do not completely tighten. • Slide the assembled storm collar down the pipe section until it rests on the roof flashing. See Figure 7.11. • Tighten nut and make sure the collar is tight against the pipe section. • Caulk around the top of the storm collar. See Figure 7.12. 01/29/2018 Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/1742 Install Vertical Termination Cap • Attach the vertical termination cap by sliding the inner collar of the cap into the inner fl ue of the pipe section while placing the outer collar of the cap over the outer fl ue of the pipe section. • Secure the cap by driving three self-tapping screws (supplied) through the pilot holes in the outer collar of the cap into the outer fl ue of the pipe. See Figure 7.12. Important Notice: Heat shields may not be fi eld constructed. F. Horizontal Termination Requirements Heat Shield Requirements for Horizontal Termination WARNING! Risk of Fire! To prevent overheating and fi re, heat shields must extend through the entire wall thick- ness. • DO NOT remove the heat shields attached to the wall shield fi restop and the horizontal termination cap (shown in Figure 7.13). • Heat shields must overlap 1-1/2 in. (38 mm) mini- mum. There are two sections of the heat shield. One section is factory-attached to the wall shield fi restop. The other section is factory-attached to the cap. See Figure 7.13. If the wall thickness does not allow the required 1-1/2 in. (38 mm) heat shield overlap when installed, an extended heat shield must be used. • If the wall thickness is less than 4 in./102 mm (DVP) or 4-3/8 in./ 111 mm (SLP), the heat shields on the cap and wall shield fi restop must be trimmed. A minimum 1-1/2 in. (38 mm) overlap MUST be maintained. • Use an extended heat shield if the fi nished wall thickness is greater than 7-1/4 in. (184 mm). • The extended heat shield may need to be cut to length maintaining suffi cient length for a 1-1/2 in. (38 mm) overlap between heat shields. • Attach the extended heat shield to either of the existing heat shields using the screws supplied with the extended heat shield. Refer to vent components diagrams in the back of this manual. • Rest the small leg on the extended heat shield on top of the pipe section to properly space it from the pipe section. Figure 7.12 01/29/2018 43Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17 Figure 7.13 Venting Through the Wall Note: When using termination caps with factory-supplied heat shield attached, no additional wall shield firestop is required on the exterior side of a combustible wall. Install Horizontal Termination Cap WARNING! Risk of Fire! The telescoping flue section of the termination cap MUST be used when connecting vent. • 1-1/2 (38 mm) minimum overlap of flue telescoping section is required. Failure to maintain overlap could cause overheating and fire. • Vent termination must not be recessed in the wall. Siding may be brought to the edge of the cap base. • Flash and seal as appropriate for siding material at outside edges of cap. • When installing a horizontal termination cap, follow the cap location guidelines as prescribed by current ANSI Z223.1 and CAN/CGA-B149 installation codes and refer to Section 4 of this manual. CAUTION! Risk of Burns! Local codes may require in- stallation of a cap shield to prevent anything or anyone from touching the hot cap. INTERIOR HEAT SHIELD OR EXTENDED HEAT SHIELDWALL SHIELD FIRESTOP HEAT SHIELD 1-1/2 IN. (38 MM) MIN. OVERLAP SHEATHING SLIP SECTION CAN BE EXTENDED INNER VENT OUTER VENT EXTERIOR 01/29/2018 Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/1744 A. General Information WARNING! Risk of Shock or Explosion! DO NOT wire 110-120 VAC to the valve or to the appliance wall switch. Incorrect wiring will damage controls. NOTICE: This appliance must be electrically wired and grounded in accordance with local codes or, in the absence of local codes, with National Electric Code ANSI/NFPA 70-latest edition or the Canadian Electric Code CSA C22.1. • Wire the appliance junction box to unswitched 110- 120 VAC. This is required for proper operation of the appliance. • A 110-120 VAC circuit for this product must be protected with ground-fault circuit-interrupter protection, in compliance with the applicable electrical codes, when it is installed in locations such as in bathrooms or near sinks. • Low voltage and 110-120 VAC voltage cannot be shared within the same wall box. • In some instances, the spark ignition of the fireplace may cause intermittent, non-damaging, interference during the lighting sequence with a TV plugged into the same circuit. It is recommended that the fireplace and TV use different circuits to mitigate the interference potential. If interference is occurring on the same circuit, the use of surge protectors may help alleviate the interference. 8 Electrical Information WHTWHTBLK BLKGRN wire inside box Copper ground attached to GRN screw with GRN wire 14/2WG Cover Plate outside firebox Romex Connector Figure 8.2 Junction Box Detail - COSMO42-IFT Junction Box Installation If the box is being wired from the INSIDE of the appliance: COSMO42-IFT: The junction box is secured to a bracket. Remove one screw. See Figure 8.2. COSMO32-IFT: The junction box is secured to the fireplace outer wrap. Remove one screw. See Figure 8.3. • Pull the electrical wires from outside the appliance through the opening into the valve compartment and secure wires with a Romex connector. See Figure 8.4. • Make all necessary wire connections to the junction box/ receptacle and reattach the junction box/receptacle to the outer shell (COSMO32-IFT) or bracket (COSMO42-IFT). Figure 8.3 Junction Box Detail - COSMO32-IFT REMOVE ONE SCREW REMOVE ONE SCREW Figure 8.4. Junction Box Wiring (Generic Model Shown) NOTICE: DO NOT wire 110-120 VAC to wall switch. BRACKET FIREBOX LEG Valve/Control Access The valve/control cavity is accessible by removing two screws located in the lower right and left corners of the fireplace opening. See Figure 8.1. Once finishing material has been installed, access to the valve/control cavity is limited to access through the fire- box, see Section 9.B. BOTTOM PANEL SCREW LOCATIONS LO W E R A C C E S S P A N E L NOTE: Appliance shown without glass installed. Figure 8.1 Remove Lower Access Panel 01/29/2018 45Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17 B. Wiring Requirements Intellifire™ Touch Ignition System Wiring NOTICE: Batteries should only be used as a power source in the event of an emergency power outage. Batteries should not be used as a primary long-term power source. Battery polarity must be correct when installing batteries. When using batteries as a power source, the 6-volt transformer must be unplugged from the receptacle. Do not store batteries in the battery pack when the appliance is powered by the 6 volt transformer connected to permanent electrical service. • Wire the appliance junction box to 110-120 VAC for proper operation of the appliance. WARNING! Risk of Shock or Explosion! DO NOT wire IPI controlled appliance junction box to a switched circuit. Incorrect wiring will override IPI safety lockout. • Refer to Figures 8.5, 8.6, and 8.7 wiring diagrams. • This appliance is equipped with an IntelliFire™ Touch control valve which operates on a 6 volt/1.5 AMP system. • Plug the 6 volt transformer plug into the appliance junction box to supply power to the unit OR install 4 AA cell batteries (not included) into the battery pack before use. Electrical Service and Repair WARNING! Risk of Shock! Label all wires prior to dis- connection when servicing controls. Wiring errors could cause improper and dangerous operation. Verify proper operation after servicing. WARNING! Risk of Shock! Replace damaged wire with type 105º C rated wire. Wire must have high temperature insulation. Accessories Requirements • This appliance may be used with a wall switch, wall mounted thermostat and/or a remote control. Wiring for optional Hearth & Home Technologies approved accessories should be done now to avoid reconstruction. Follow instructions that come with those accessories. 01/29/2018 Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/1746 Figure 8.5 Intellifire™ Touch Wiring Diagram - Standard 6 VAC TRANSFORMER 2326-131 6V BATTERY PACK 2326-134 ORANGEGREENGROUND TO FIREPLACE CHASSIS WHITE ORANGE INTERMITTENT PILOT IGNITER (NG) 2106-169 HOTNEUTRALJUNCTION BOX 110-120 VAC I S IFT CONTROL MODULE 2326-130 VALVE (NG) 2166-302 BLK BLACK RED GREEN ORANGE BRN RED RED WHITE WIRE ASSEMBLY 2118-170 WIRE HARNESS 2326-132 JUMPER 2187-198 Note: Wire assembly (2118-170) is shipped in the manual bag assembly. Usage is optional. Note: Battery Pack (2326-134) is attached to the back side of the lower cover panel. Connect battery pack to control system at the time of installation. 01/29/2018 47Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17 Figure 8.6 Intellifire™ Touch Wiring Diagram with Remote, Fan and LED Options JUNCTION BOX 110-120 VAC LEDCONTROL RF MODULE2326-120 ORANGE (PILOT) RED 6V DC BATTERY PACK 2326-134 BLK RED JUMPER WIRE APPLIANCE ON/OFF CONTROL BRN BLK OPTIONS FAN GFK-160A IFT-RC150 WIRELESS WALL SWITCH IFT-RC400 REMOTE CONTROL IFT-AUX AC MODULE CABLE 2326-152 RF MODULE 2326-120 RF MODULE 2326-120 2326-150 LED’s GREEN (MAIN) WIRE HARNESS NOT USED 6 VAC TRANSFORMER 2326-131 HOTNEUTRALINTERMITTENT PILOT IGNITER (NG) 2106-169 IFT CONTROL MODULE 2326-130 IFT AUX 2326-150 AC MODULE CABLE 2326-152 LED-LINEAR Components shown in diagram. FAN OUTLET 01/29/2018 Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/1748 Figure 8.7 Intellifire™ Touch Wiring Diagram with Power Vent Diagram 6 VAC TRANSFORMER 2326-131 ORANGEGREENGROUND TO FIREPLACE CHASSIS WHITE ORANGE INTERMITTENT PILOT IGNITOR (2106-169)HOTNEUTRALJUNCTION BOX 110-120 VAC I S IFT CONTROL MODULE 2326-130 VALVE (NG) 2166-302 BLK GREEN ORANGE BRN WIRE HARNESS 2326-132 AC MODULE CABLE 2326-152 RF MODULE 2326-120 IFT AUX 2326-150 IFT-RC400 REMOTE CONTROL 2326-110 OPTIONAL FAN GFK-160A JUMPER 2155-033 PVI-SLP-BPVLP-SLP PVI-SLP-B OR PVLP-SLP WIRE HARNESS PVI-WH10 PVI-WH20 PVI-WH40 PVI-WH60 PVI-WH80 PVI-WH100 RED 01/29/2018 49Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17 9 Gas Information A. Fuel Conversion • Make sure the appliance is compatible with available gas types. • Conversions must be made by a qualified service technician using Hearth & Home Technologies specified and approved parts. B. Gas Pressure • Optimum appliance performance requires proper input pressures. • Gas line sizing requirements will be determined in ANSI Z223.1 National Fuel Gas Code in the USA and CAN/ CGA B149 in Canada. • Pressure requirements are: WARNING! Risk of Fire or Explosion! High pressure will damage valve. Low pressure could cause explosion. • Verify inlet pressures. Verify minimum pressures when other household gas appliances are operating. • Install regulator upstream of valve if line pressure is greater than 1/2 psig. Gas Pressure Natural Gas Propane Minimum inlet pressure 5.0 in. w.c.11.0 in. w.c. Maximum inlet pressure 10.0 in. w.c.13.0 in. w.c. Manifold pressure 3.5 in. w.c.10.0 in. w.c. Note: Have the gas supply line installed in accordance with local codes, if any. If not, follow ANSI 223.1. Installation should be done by a qualified installer approved and/or licensed as required by the locality. (In the Commonwealth of Massachusetts installation must be performed by a licensed plumber or gas fitter). Note: A listed (and Commonwealth of Massachusetts ap- proved) 1/2 in. (13 mm) T-handle manual shut-off valve and flexible gas connector are connected to the 1/2 in. (13 mm) control valve inlet. • If substituting for these components, please consult local codes for compliance. Fire Risk. Explosion Hazard. High pressure will damage valve. • Disconnect gas supply piping BEFORE pressure testing gas line at test pressures above 1/2 psig. • Close the manual shutoff valve BEFORE pressure testing gas line at test pressures equal to or less than 1/2 psig. WARNING REMOVE 2 SCREWS Figure 9.1 Basepan Removal - COSMO42-IFT Shown Access Through the Valve Assembly (For Service/Conversion) 1. Locate and remove the two screws that secure the basepan to the appliance. See Figure 9.1. Remove basepan. Retain screws. Access Through the Control Cavity (For Service/Conversion) The lower access cover panel is removable if finishing material has not been previously installed. See Section 8.A for removal instructions. 01/29/2018 Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/1750 Figure 9.3 Remove Valve Plate Figure 9.2 Burner Removal Valve Pressure Taps The pressure taps are accessible by removing the lower panel prior to finishing material installation. There is limited access to the pressure taps after finishing material installation. Remove glass assembly and utilize an appropriate sized screwdriver. Note: Install the gas supply line in accordance with local codes, if any. If not, follow ANSI 223.1. Installation should be done by a qualified installer approved and/or licensed as required by the locality. (In the Commonwealth of Massachusetts installation must be performed by a licensed plumber or gas fitter). Note: A listed (and Commonwealth of Massachusetts ap- proved) 1/2 in. (13 mm) T-handle manual shut-off valve and flexible gas connector are connected to the 1/2 in. (13 mm) control valve inlet. • If substituting for these components, please consult local codes for compliance. 2. Remove the two screws that secure the pilot shield to the burner bracket and remove the two screws that secure the pilot assembly to the burner bracket. Remove the one screw that secures the burner bracket to the valve plate. See Figure 9.2. Gently push the pilot assembly backwards to allow for the burner to be removed. 3. Remove the screw that secures the burner bracket to the valve plate. See Figure 9.2. 4. Slide burner assembly to the left to disengage the burner tube from the orifice. Remove the burner from the appliance. 5. Remove the nine screws around the perimeter of the valve plate that secure valve plate to the appliance. See Figure 9.3. 6. Lift up on the plate assembly. Ensure the gas ball valve is turned off. Disconnect the ball valve assembly from the gas valve by loosening the compression fitting located on the left side of the gas valve. 7. Prior to removing valve assembly for service, disconnect the pilot wires from the ignition module. 8. Upon completion of service, reverse steps 1-7. If the valve plate gasket is damaged, replace the gasket prior to reinstallation of valve plate assembly. REMOVE 9 SCREWS REMOVE BURNER SCREW REMOVE PILOT SCREWS 01/29/2018 51Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17 D. High Altitude Installations NOTICE: If the heating value of the gas has been reduced, these rules do not apply. Check with your local gas utility or authorities having jurisdiction. When installing above 2000 feet elevation: • In the USA: Reduce input rate 4% for each 1000 feet above 2000 feet. • In CANADA: Input ratings are certified without a reduction of input rate for elevations up to 4500 feet (1370 m)above sea level. Please consult provincial and/ or local authorities having jurisdiction for installations at elevations above 4500 feet (1370 m). Check with your local gas utility to determine proper orifice size. C. Gas Connection • Refer to Reference Section 3 for location of gas line access in appliance. • Gas line may be run through knockout(s) provided. • The gap between supply piping and gas access hole may be caulked with caulk with a minimum of 300 ºF continuous exposure rating or stuffed with non- combustible, unfaced insulation to prevent cold air infiltration. • Ensure that gas line does not come in contact with outer wrap of the appliance. Follow local codes. • Pipe incoming gas line into valve compartment. • Connect incoming gas line to the 1/2 in. (13 mm) connection on manual shutoff valve. WARNING! Risk of Fire or Explosion! Support control when attaching pipe to prevent bending gas line. • A small amount of air will be in the gas supply lines. WARNING! Risk of Fire or Explosion! Gas build-up during line purge could ignite. • Purge should be performed by qualified service technician. • Ensure adequate ventilation. • Ensure there are no ignition sources such as sparks or open flames. Light the appliance. It will take a short time for air to purge from lines. When purging is complete the appliance will light and operate normally. WARNING! Risk of Fire, Explosion or Asphyxiation! Check all fittings and connections with a non-corrosive commercially available leak-check solution. DO NOT use open flame. Fittings and connections could have loos- ened during shipping and handling. WARNING! Risk of Fire! DO NOT change valve settings. This valve has been preset at the factory. E. Air Shutter Setting Air shutter settings should be adjusted by a qualified ser- vice technician at the time of installation. The air shutter is set at the factory for minimum vertical vent run. Adjust air shutter for longer vertical runs. See Figure 9.4. • Loosen the 1/4 inch screw. • Twist the air shutter to adjust. • Air shutter may be opened for longer horizontal vent runs. • Tighten the 1/4 inch screw. NOTICE: If the flames appear to be orange or sooting occurs, open the air shutter to prevent residue buildup on the glass. Figure 9.4 Air Shutter Location Air Shutter Settings NG LP COSMO32-IFT 1/16 in.1/8 in. COSMO42-IFT 1/16 in.3/16 in. 01/29/2018 Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/1752 10 Finishing A. Facing Materials WARNING! Risk of Fire! Comply with all minimum clear- ances to combustibles as specified. Framing closer than the minimums listed must be constructed entirely of noncom- bustible materials (i.e., steel studs, concrete board, etc.) The appliance is designed to accept 1/2 in. wall sheathing materials such as drywall, plywood, wood composites, or non-combustible materials. The type of material used depends whether the installation is an Inside or Overlap Fit Method. Refer to Section 10.D regarding installation details associated with the Inside and Overlap Fit methods. The factory-supplied non-combustible board must be used in all installations. It must be directly attached to structural framing adjacent to the appliance. Screw fas- teners should be installed in the pilot holes provided in the outer perimeter of the non-combustible board. See Figure 10.1 and Figure 10.2. The factory-supplied board is designed such that its edg- es will be at the approximate center of the adjacent fram- ing, assuming it is 1-1/2 in. nominal thickness. This will allow the wallboard joints to occur on the center of the framing where the panels can be fastened properly. If the framing thickness is less than 1-1/2 in. nominal, such as with formed steel systems, then it may be necessary to adjust the adjacent framing dimensions so that the non- combustible board and wallboard joints are centered on the framing. Finishing Instructions It is important to follow the framing and finishing instruc- tions to ensure proper placement of fireplace into the sur- rounding framing/finishing materials. Wall sheathing materials 1/2 in. thick are specified in this installation manual to properly align with the factory- installed non-combustible material. WARNING! Risk of Fire! DO NOT remove the factory- installed non-combustible board or cover it with combus- tible material, such as: • Drywall (gypsum board) • Plywood • Materials that do not meet the ASTM E 136 Non-com- bustibility standard (below). Removal of factory-installed, non-combustible board and/ or use of materials not meeting the ASTM E 136 standard may cause fire. • Facing and/or finishing materials must not interfere with air flow through decorative fronts. • Facing and/or finishing materials must never overhang into the glass opening. Non-Combustible Materials Specification Material which will not ignite and burn. Such materials are those consisting entirely of steel, iron, brick, tile, concrete, slate, glass or plasters, or any combination thereof. Materials that are reported as passing ASTM E 136, Standard Test Method for Behavior of Materials in a Vertical Tube Furnace at 750 ºC. • Observe all clearances when applying combustible materials. WARNING! Risk of Fire! DO NOT apply combustible materials beyond the minimum clearances. Comply with all minimum clearances to combustibles as specified in this manual. Overlapping materials could ignite and will interfere with proper operation of decorative fronts. WARNING! Risk of Fire! DO NOT install drywall or other combustible materials over the factory-installed non-com- bustible board. Overlapping materials could ignite. Decorative facing material thickness is measured from the face of the factory-installed non-combustible board. See Section 10.D for Overlap Fit and Inside Fit require- ments. 01/29/2018 53Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17 B. Non-Combustible Board and Drywall In- stallation Introduction If the desired finished fireplace installation does not utilize non-combustible finishing materials (such as tile, marble, stone, etc.), special attention must be paid to the instal- lation of drywall/gypsum wallboard to minimize potential development of cracking and paint discoloration. Hearth and Home Technologies has tested the following methods and materials and therefore recommends the following steps for the best drywall performance. Attaching Non-Combustible Board to Framing 1. To ensure the lower cover panel has been correctly installed, verify that two screws (total) have been in- stalled in the lower left and right sides of the fireplace opening. See Figure 8.1. These screws, when in- stalled, will ensure the lower panel is correctly installed. If the lower cover panel is not correctly installed, the decorative front may not fit into the fireplace opening correctly. Refer to section 6.D for more information regarding the included non-combustible board. 2. The appliance ships with the required non-combus- tible board. The large top piece of non-combustible board is pre-installed at the factory. The narrow left and right non-combustible pieces are shipped within the appliance. Install the non-combustible side pieces with the screws provided in the manual bag assembly. There are pilot holes located on the left and right side columns. Care should be taken not to tighten these screws into the non-combustible board excessively. Set screws flush to the face of the non-combustible board. See Figure 10.2 and Section 6.D. 3. The outer perimeter of the factory-installed non-com- bustible board has pre-drilled pilot holes. See Figure 10.1. Secure the non-combustible board to adja- cent framing with drywall screws that are a minimum of 1-1/4 inch in length. Care should be taken not to tighten these screws into the non-combustible board excessively. Set screws flush to the face of the non- combustible board. See Figure 10.2 and Section 6.D. 4. When installing drywall around the appliance, install a rectangular hole for the fireplace/non-combustible board in a single sheet of drywall. This will minimize the joints that require finishing adjacent to the fireplace opening. Ensure that the 1/8 inch gap is maintained between the factory installed non-combustible board and the surrounding drywall. See Figure 10.1. Secure the drywall to the framing with screws a minimum of one inch in length every six inches across the top of the fireplace and every ten inches on the sides of the fireplace. 5. To ensure good adhesion of drywall compounds and tape, thoroughly clean the non-combustible board and surrounding drywall to remove dust. PRE-DRILLED PILOT HOLES APPLIANCE OPENING FILL GAPS Figure 10.1 Install Non-Combustible Board Filling and Finishing Seams 1. Fill all gaps and joints between the non-combustible board pieces and the drywall with a general purpose chemically hardening joint compound. Hearth and Home Technologies recommends Durabond® 45 Joint Compound manufactured by USG (Sheetrock® brand). Use a drywall knife to firmly press the joint compound into all gaps. See Figure 10.1. Allow these joints to dry. 2. All joints are to be taped with a paper tape and embed- ded with Durabond® 45 Joint Compound manufac- tured by USG (Sheetrock® brand). Allow these joints and paper tape to dry. 3. Depending on the technique used in steps 1 and 2, two to three finishing coats are required to provide a smooth and durable finish. Hearth and Home Tech- nologies recommends ProForm® Lite-Blue Joint Com- pound manufactured by National Gypsum. Allow each coat to properly cure. Allow the finishing coat(s) to cure for 24 hours before operating appliance. Painting If desired finishing includes a painted wall, a high-quality 100% acrylic latex paint with a high-quality latex primer base coat are recommended around the appliance to limit discoloration. Oil-based or standard acrylic paints may be more prone to discoloration due to heat exposure. Drywall Joint-Crack Prevention and Repair Drywall joints around the fireplace will be affected by ex- posure to elevated temperatures, along with other envi- ronmental, structural factors due to new construction, and methods used to install and finish the drywall. If a crack does emerge adjacent to the fireplace, it can be perma- nently repaired by filling it with a paintable latex caulk, followed by repainting. Some movement of the screws used to secure the non- combustible board to the appliance/surround framing is expected. If a blemish begins to show over a screw head, sand the surface to remove the blemish and repaint.01/29/2018 Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/1754 WARNING! Risk of Fire! Maintain specified air space clearances to combustibles. Failure to comply with these instructions may cause a fire or cause the appli- ance to overheat. CAUTION! Risk of Glass Damage and Cuts! DO NOT drill or install any type of screw or fastener into the lower cover panel. Sharp screw or fastener tips may penetrate and break the glass or cause cuts. Note: It is acceptable to use a silicone sealant with a minimum of 300 ºF continuous exposure rating to adhere drywall to lower cover panel. The final fireplace installation can be accomplished by either the Overlap Fit or Inside Fit method. Reference Section 10.D regarding installation details associated with the Inside Fit and Overlap Fit methods. It is acceptable to pre-drill holes and use self-tapping screws in the installed non-combustible board to attach non-combustible backer board for tile, marble, etc. Refer to Figure 10.2 for acceptable screw or metal lath location and screw length requirements. Do not drill or install screws which may penetrate the lower cover panel as this will restrict required access to the glass, battery-backup, and control module. See Figure 10.2. Note: If the desired look is painted drywall, it is recommended that no additional screws are installed into the factory-provided non-combustible board. Only install the screws provided into the pilot holes located in the factory-provided non-combustible board. Figure 10.2 Finishing Details - COSMO42-IFT and COSMO32-IFT WARNING! Risk of Fire! Maintain specified air space clearances to combustibles. Inadequate air space could cause overheating and fire. FACTORY-INSTALLED NON-COMBUSTIBLE BOARD LOWER COVER PANEL = NO SCREWS ALLOWED = 1 INCH. MAX. SELF-TAPPING SCREWS ALLOWED = 5 INCH - 7 INCH SELF-TAPPING SCREWS ALLOWED PILOT HOLES (11 LOCATIONS) TO ATTACH NON-COMBUSTIBLE BOARD TO FRAMING 01/29/2018 55Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17 C. Mantel and Wall Projections WARNING! Risk of Fire! Comply with all minimum clear- ances as specified. Framing closer than the minimums list- ed must be constructed entirely of non-combustible materi- als (i.e., steel studs, concrete board, etc.). Note: Measurement is taken from top of the opening, NOT the top of the fireplace. Figure 10.3 Clearances To Combustibles Mantels Or Other Combustibles Above Appliance Combustible Mantels Non-combustible Mantels Figure 10.4 Clearances To Non-Combustible Mantels Or Other Non-Combustibles Above Appliance 1/2 IN. THICK WALL SHEATHING 12 IN. MAX. 14 IN. MIN. BOTTOM OF MANTEL TO TOP OF APPLIANCE OPENING COMBUSTIBLE MANTEL APPLIANCE OPENING 12 IN.MAX. 1/2 IN. THICK WALL SHEATHING 14 IN. MIN. BOTTOM OF MANTEL TO TOP OF APPLIANCE OPENING NON-COMBUSTIBLE MANTEL 6 IN. MAX. NON- COMBUSTIBLE MANTEL APPLIANCE OPENING 01/29/2018 Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/1756 Figure 10.5 Combustible or Non-Combustible Mantel Leg or Wall Projections (Acceptable on both sides of opening) Figure 10.6 Combustible or Non-Combustible Mantel Leg or Wall Projections - Unlimited Wall Length (Acceptable on both sides of opening) Note: Clearance from opening to perpendicular wall. Mantel Legs Or Wall Projections Extending Past The Face Of The Fireplace (Combustible or Non-Combustible) WALL 3 FT. MAX. 6 IN. MIN. APPLIANCE OPENING Note: Clearance from opening to perpendicular wall. WALL UNLIMITED 7 IN. MIN. APPLIANCE OPENING 01/29/2018 57Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17 D. Decorative Front Finishing WARNING! Risk of Fire! A decorative front is required for this model. DO NOT operate this appliance without a decorative front in place. Only decorative fronts certified for use with this appliance model may be used. Contact your dealer for a list of deco- rative fronts that may be used. FRONT FACE OF FIREPLACE DECORATIVE FRONT 1 IN. MAX. FINISHING MATERIAL (TOP EDGE) Figure 10.7 Overlap Fit Decorative Front (CFT and Martini Decorative Fronts) Finishing materials 1 inch maximum thick. Stop finishing material flush with opening. Overlap Fit - CFT and Martini Decorative Fronts (0 Inches to 1 Inch Thick Finishing Material) Figure 10.8 Overlap Fit Method (CFT and Martini Decorative Fronts) FACTORY-INSTALLED NON-COMBUSTIBLE BOARD NON-COMBUSTIBLE FINISHING MATERIAL 0 - 1 IN. THICK NON-COMBUSTIBLE FINISHING MATERIAL 0 - 1 IN. THICK CFT DECORATIVE FRONT SHOWN DRYWALL OR EQUIVALENT (1/2 IN.) Both the CFT and Martini decorative fronts are designed to overlap finish materials 0 inches to 1 inch thick. See Figure 10.7 and Figure 10.8. NOTICE: This one inch maximum not only includes the decorative finish materials (marble, tile, slate, etc) but also the mortar or adhesive used to attach the decorative finish material. The non-combustible finish material can be installed up to the fireplace opening. 01/29/2018 Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/1758 Figure 10.9 Maximum Finish Material Thickness - CFT Decorative Front Inside Fit - CFT Front (1 Inch to 6 Inch Thick Finishing Material) FINISHING MATERIAL 6 IN. MAXIMUM THICKNESS FINISHING MATERIAL 6 IN. MAXIMUM THICKNESS CFT Decorative Front Non-Combustible Finish Material 1-6 Inches Thick 1-3/16 IN. 1-3/16 IN. (CFT) 1-3/16 IN. Figure 10.10 Clearances to Appliance Opening With Outer Deco- rative Front Trim Figure 10.11 CFT Front Installation With Outer Decorative Front Trim OUTER DECORATIVE FRONT TRIM INNER DECORATIVE FRONT ASSEMBLYTOP VANITY PANEL (NOT SHOWN) TABS (4) FA C E O F N O N - C O M B U S T I B L E B O A R D The CFT is the only approved front for inside fit applications (finish material over 1 inch thick). The CFT decorative front can be installed with or without the outer decorative front trim (included with the decorative front). See Figure 10.9. If the desired look is to include the outer decorative front trim, finishing materials up to 1-3/16 around the fireplace opening. See Fig 10.10. For this installation, the inner decorative front hangs on four tabs located on outer decorative front trim. The auxiliary hanging brackets are not used and may be discarded. See Figure 10.11. If the desired look is to exclude the outer decorative front trim, finishing material can be installed up to the fireplace opening. See Fig 10.12. For this installation, the inner decorative front hangs on four tabs located on the auxiliary hanging brackets. The outer decorative front trim is not used and may be discarded. See Figure 10.13. 01/29/2018 59Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17 (BOTH SIDES) (BOTH SIDES) FAC E O F N O N - C O M B U S T I B L E B O A R D AUX I L I A R Y H A N G I N G BR A C K E T S Figure 10.13 CFT Front Without Outer Decorative Front Trim CFT Decorative Front Non-Combustible Finish Material 1-6 Inches Thick 0 IN. 0 IN. (CFT) 0 IN. Figure 10.12 Clearances to Appliance Opening Without Outer Decorative Front Trim 01/29/2018 Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/1760 A. Remove Fixed Glass Assembly WARNING! Risk of Asphyxiation! Handle fixed glass assembly with care. Inspect the gasket to ensure it is undamaged and inspect the glass for cracks, chips or scratches. • DO NOT strike, slam or scratch glass. • DO NOT operate fireplace with glass removed, cracked, broken or scratched. • Replace as a complete assembly. Removing Fixed Glass Assembly 1. Remove the decorative front. 2. The glass assembly has two upper spring latches and two lower spring latches. See Figure 11.1. Lo- cate the two spring latches that are on the upper left and right of the fireplace. 3. Pull upper spring latch on one side forward to release glass assembly while supporting glass assembly with opposite hand. Repeat for the other upper spring latch always taking care to support the glass assem- bly with one hand. 4. Grasp glass on the upper right and left sides and remove glass assembly by lifting “up” and “out”. Note: Observe the presence of a space or gap between the glass latch and the front of the appliance where the bottom of the glass assembly is positioned. This gap is designed for positive placement when replacing the glass assembly. See Section 11.I. 11 Appliance Setup Figure 11.1 Fixed Glass Assembly D. Install the Glass Refractory (Optional) An optional glass refractory kit is available for use with the COSMO42-IFT and COSMO32-IFT models. Install the glass refractory per instructions included with the kit. C. Clean the Appliance Clean/vacuum any sawdust that may have accumulated inside the firebox or underneath in the control cavity. UPPER SPRING LATCH LOWER SPRING LATCH GAP B. Remove the Shipping Materials Remove shipping materials from inside or underneath the firebox. • The splatter guard is a piece of corrugated material used to protect the appliance during the installation process before finishing work on the whole hearth is complete. Splatter guards may be factory installed or accompany the decorative front of the appliance, depending on the fireplace model. Splatter guards must be removed before appliance is fired. • The left and right side non-combustible boards are packaged within the splatter guard. Remove them by carefully disengaging the tabs from the slots on the lower portion of the splatter guard. Install as instructed in Section 6. WARNING! Risk of Fire! Close the ball valve before in- stalling the splatter guard to prevent accidental lighting. Remove the splatter guard before lighting the appliance. 01/29/2018 61Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17 F. Install Media Decorative glass media is included with the COSMO42- IFT and COSMO32-IFT models. Placing the Media Install glass media around the burner ensuring that no media is placed on the burner or in the gap located be- hind the burner. See Figure 11.2. Install media on top of pilot shield. WARNING Delayed Ignition Risk • Place media according to instructions. • Do NOT place media in area in front of pilot • Do NOT place media in a position that they may fall into area in front of pilot. • Do NOT use any media other than the Hearth & Home Technologies-supplied options for this fireplace model. Fireplace will not function properly. Delayed ignition may occur. WARNING Risk of Asphyxiation or Fumes. • Place media according to instructions. • Do NOT place media in area between glass and firebox. • Do NOT place media in a position that they may fall into area between glass and firebox. • Do NOT use any media other than the media supplied with this fireplace. Fireplace will not function properly. Gas leak may occur. Figure 11.2 Media Placement PILOT SHIELD NO MEDIA ON BURNER NO MEDIA IN GAP G. Install Stones (Optional) An optional stones kit is available for use with the COS- MO42-IFT and COSMO32-IFT models. Install the stones per instructions included with the kit. H. Install Log Sets (Optional) Optional log sets are available for use with the COSMO42- IFT and COSMO32-IFT models. Install the log set per instructions included with the kit. I. Install Fixed Glass Assembly WARNING! Risk of Asphyxiation! Handle fixed glass assembly with care. Inspect the gasket to ensure it is undamaged and inspect the glass for cracks, chips or scratches. • DO NOT strike, slam or scratch glass. • DO NOT operate fireplace with glass removed, cracked, broken or scratched. • Replace as a complete assembly. Replacing Fixed Glass Assembly The bottom glass latches have been designed to create a small gap between the glass clip and the face of the appliance. See Figure 11.1. 1. Install the bottom of the glass assembly so that the two tabs on the bottom of the glass latch engage the gap. By tilting the top of the glass towards the face of the appliance, tension will be applied to the bottom two glass latches. Use one hand to support the glass at all times. 2. Fasten the two upper glass latches, one at a time, by pulling out and downward into position on the glass assembly. Use one hand to support the glass at all times. 3. Verify that the top two glass latches are engaged by visually verifying that glass latches have engaged both left and right tabs on the glass frame. 4. Verify the bottom two glass latches have engaged the glass frame tabs by grasping the bottom of the glass frame assembly and pulling the glass frame assembly “away” from the face of the appliance and “release” the glass frame. The spring action of the clips will “pull” the glass frame assembly towards the face of the appliance if bottom clips are properly engaged. If the glass frame assembly does not pull back towards the face of the appliance, repeat steps 1-4. WARNING! Risk of Explosion! Risk of Asphyxiation! Glass latches MUST be properly engaged. Inspect glass seal before installing decorative front. Gas could leak! 5. Reinstall decorative front. E. Install LED Lights (Optional) An optional LED light kit is available for use with the COSMO42-IFT and COSMO32-IFT models. Install the LED lights per the instructions included in the kit. 01/29/2018 Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/1762 J. Install Decorative Front WARNING! Risk of Fire! Install ONLY decorative fronts approved by Hearth & Home Technologies. Unapproved decorative fronts could cause fireplace to overheat. IMPORTANT! This fireplace requires an integral barrier to prevent direct contact with the hot viewing glass. DO NOT operate the fireplace with the barrier removed. Contact your dealer or Hearth & Home Technologies if the barrier is not present or help is needed to properly install one. For more information refer to the instructions supplied with your decorative front. 01/29/2018 63Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17 12 Reference Materials A. Vent Components Diagrams Figure 12.1 SLP Series Vent Components 8-3/4 in. 222 mm 6-1/2 in. 165 mm 6-5/8 in. 168 mm 6 in. 152 mm 6-1/2 in. 165 mm 6-5/8 in. 168 mm 9-7/8 in. 251 mm 6-1/2 in. 165 mm9-1/4 in. 235 mm SLP45 45° Elbow SLP90 90° Elbow Effective Height/ Length SLP PIPE SLP-HVS Horizontal Pipe Support SLP-FS Ceiling Firestop SLP-WS Wall Shield Firestop 10-7/8 in. 276 mm 8-7/8 in. 225 mm 1-1/2 in. 38 mm 8-11/16 in. 220 mm 8-11/16 in. 220 mm 1-1/2 in. 38 mm 12 in. 305 mm 12 in. 305 mm 5-1/2 in. 146 mm Effective Height/Length Pipe inches mm SLP4 4 102 SLP6 6 152 SLP12 12 305 SLP24 24 610 SLP36 36 914 SLP48 48 1219 SLP6A 2 - 6 51 - 152 SLP12A 2 - 12 51 - 305 SLP-FLEX-2 24 610 SLP-FLEX-3 36 914 SLP-FLEX-5 60 1524 SLP-FLEX-10 120 3048 01/29/2018 Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/1764 A. Vent Components Diagrams (continued) Figure 12.2 SLP Series Vent Components SLP-WT-BK Wall Thimble-Black SL-2DVP Adapter 26 in. 660 mm DVP-HSM-B Extended Heat Shield SLP-TRAP Horizontal Termination Cap 15-1/8 in. (384 mm) Note: Heat shields MUST overlap by a minimum of 1-1/2 in. (38 mm). The heat shield is designed to be used on a wall 4 in. to 7-1/4 in. (102 mm to 184 mm) thick. If wall thickness is less than 4 in. (102 mm) the existing heat shields must be field trimmed. If wall thickness is greater than 7-1/4 in. (184 mm) a DVP-HSM-B will be required. Heat Shield Term Cap Minimum Effective Length Maximum Effective Length Trap1 3-1/8 in. 4-3/4 in. 79 mm 121 mm Trap2 5-1/4 in. 9-1/4 in. 133 mm 235 mm 8 in. (203 mm) 12 in. (305 mm) Max Effective Length 14-7/16 in. 367 mm 14-7/16 in. 367 mm 2-5/16 in. 59 mm 3-15/16 in. (101 mm) 6-11/16 in. (169 mm) 8 in. (203 mm) 3-15/16 in. (101 mm) 3-13/16 in. (97 mm) 5-1/16 in. (128 mm) 12-5/8 IN. (321 mm) 12-5/8 IN. (321 mm) 20 IN. (508 mm) 10-5/8 IN. (270 mm) SLP-RDS ROOF DECK INSULATION SHIELD 01/29/2018 65Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17 1 in. (25 mm) 14 in. (356 mm) 3/8 in. (10 mm) 1 in. (25 mm) 7-1/4 in. (184 mm) 7-3/4 to 10-3/8 in. (197 to 264 mm) 13 in. 330 mm 13 in. 330 mm 1-5/16 in. 34 mm10-9/16 in. 269 mm 14 in. 356 mm 12-1/2 in. 318 mm 12 in. 305 mm SLP-FLEX-TRAP Horizontal Termination Kit 14 in. 356 mm 14-1/16 in. 357 mm 7-1/2 in. 192 mm 10-3/4 in. 273 mm SLP-CCS-BK Cathedral Ceiling Support Box-Black SLP-DCF-BK Ceiling Firestop Black SLK-SNKD Snorkel Termination Cap SLP-TVHW Vertical Termination Cap DVP-FBHT Horizontal Termination Cap (SL-2DVP Required) 13-1/2 in. 343 mm 28-1/2 in. 724 mm 10-11/16 in. 271mm 17-7/8 IN. 454 mm 7-3/8 IN. 187 mm 14 IN. 356 mm 12 IN. 305 mm SLP-TB1 Basement Vent Cap 4-3/4 in. 121 mm 4-1/8 in. 105 mm 6 IN.152 mm A. Vent Components Diagrams (continued) Figure 12.3 SLP Series Vent Components 01/29/2018 Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/1766 LINK-DV30B Flex Liner Kit DV-46DVA-GCL Coaxial/Colinear Appliance Connector 768-380A Stainless Steel Flex Pipe (Required on COSMO32-IFT) COAXIAL to COLINEAR VENTING Figure 12.5 Coaxial to Colinear Vent Components SLP-HHW2 Horizontal High Wind Termination Cap 15 IN. (381 mm) 12 IN. (305 mm) 8 IN. (203 mm) Figure 12.4 SLP series Vent Components 01/29/2018 67Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17 Figure 12.6 PVI-SLP-B Vent Components Optional Wire Harness DESCRIPTION PART NUMBER 10 FT PV Wire Harness PVI-WH10 20 FT PV Wire Harness PVI-WH20 40 FT PV Wire Harness PVI-WH40 60 FT PV Wire Harness PVI-WH60 80 FT PV Wire Harness PVI-WH80 100 FT PV Wire Harness PVI-WH100 PVI-SLP-B Power Vent Inline SLP-LPC SLP Low Profile Cap (Approved for use with PVI-SLP-B only) Note: Wire harnesses required to power the PVI-SLP-B connect to the appliance and are ordered separately from PVI-SLP-B. Contact your dealer to order. 16 IN. 406 mm 15 IN. (381 mm) 16-11/16 IN. (424 mm) 9-3/16 IN. (233 mm) 4-1/2 IN. 114 mm 16-11/16 IN. 424 mm 13-5/8 IN. (346 mm) 12-1/2 IN. (318 mm) 12-1/2 IN. 318 mm 20-3/4 IN. 527 mm 13-5/8 IN. 346 mmEFFECTIVE LENGTH 32 IN. (813 mm) MIN. 35 IN. (889 mm) MAX. Note: The PVLP-SLP requires one of the following options to be installed on this appliance. Option A: IFT-RC400 OR Option B: IFT-RC150 and IFT-ACM. These accessories are purchased separately from the PVLP-SLP. Contact your dealer to order. 01/29/2018 Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/1768 A. Vent Components Diagrams (continued) Required Wire Harness DESCRIPTION PART NUMBER 10 FT PV Wire Harness PVI-WH10 20 FT PV Wire Harness PVI-WH20 40 FT PV Wire Harness PVI-WH40 60 FT PV Wire Harness PVI-WH60 80 FT PV Wire Harness PVI-WH80 100 FT PV Wire Harness PVI-WH100 Note: Wire harnesses required to power the PVLP-SLP connect to the appliance and are ordered separately from PVLP-SLP. Contact your dealer to order. Figure 12.7 PVLP-SLP Vent Components PVLP-HS Heat Shield 14 IN. 356 mm 15-1/2 IN. 394 mm 11-1/2 IN. 292 mm 8 IN. 203 mm 4-3/8 IN. 112 mm 10 IN. 254 mm 5-1/4 IN. 135 mm 2-1/4 IN. 57 mm 9-1/2 IN. 241 mm 4-3/4 IN. 121 mm 2-1/4 IN. 57 mm 1-1/2 IN. 38 mm 6-1/4 IN. 159 mm Front View Top View Side View Note: A PVLP-HS heat shield is available and sold separately. Use if the PVLP-SLP is installed in a high traffic area. PVLP-BEK Brick Kit PVLP-SLP Power Vent Low Profile Note: The PVLP-SLP requires one of the following options to be installed on this appliance. Option A: IFT-RC400 OR Option B: IFT-RC150 and IFT-ACM. These accessories are purchased separately from the PVLP-SLP. Contact your dealer to order. 01/29/2018 69Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17 B. Accessories Printed in U.S.A. - Copyright 2017 Heat & Glo, a brand of Hearth & Home Technologies 7571 215th Street West, Lakeville, MN 55044 www.heatnglo.com Please contact your Heat & Glo dealer with any questions or concerns. For the location of your nearest Heat & Glo dealer, please visit www.heatnglo.com. Remote Controls, Wall Controls and Wall Switches After a qualified service technician has installed the re- mote control, wall control or wall switch, follow the in- structions supplied with the control installed to operate your fireplace: For safety: • Install a switch lock or a wall/remote control with child protection lockout feature. • Keep remote controls out of reach of children. See your dealer if you have questions. Install approved accessories per instructions included with accessories. Contact your dealer for a list of ap- proved accessories. It is recommended that optional accessories are installed prior to installation of finishing material. The lower cover panel is removable and provides access for installation of the optional fan, LED kit and remote control upgrades. If finishing material is already installed, the optional acces- sories must be installed by removing the basepan, burner and valve assembly. Use only Hearth & Home Technol- ogies-approved optional accessories with this appliance. WARNING! Risk of Fire and Electric Shock! Use ONLY Hearth & Home Technologies-approved optional acces- sories with this appliance. Using non-listed accessories could result in a safety hazard and will void the warranty. Optional Fan After a qualified service technician has installed the fan, follow the instructions supplied with the fan kit to operate your fan. See your dealer if you have questions. Optional Glass Refractory Kit An optional glass refractory kit is available for COSMO32- IFT and COSMO42-IFT. Follow the instructions supplied with the kit for installation. Contact your dealer if you have questions. Optional Log Kits Traditional or Driftwood Log kits are available for COS- MO32-IFT and COSMO42-IFT. Follow the instructions supplied with the kit for installation. Contact your dealer if you have questions. Optional LED Kit An optional LED lighting kit is available for COSMO32- IFT and COSMO42-IFT. Follow the instructions supplied with the kit for installation and operation. Contact your dealer if you have questions. Optional Stones Kit An optional stones kit is available for use with the COS- MO42-IFT and COSMO32-IFT models. Follow the instruc- tions supplied with the kit for installation. Contact your dealer if you have questions. Optional Heat Management Systems After a qualified service technician has installed the Heat- Zone® -Gas, Smart-Wall™ TV Kit, Heat-Duct Kit, or Heat- Out-Gas Kit, follow the instructions supplied with the kit for operation. Contact your dealer if you have questions. Note: Optional heat management systems kit must be installed while the sides of the appliance are accessible. 01/29/2018