HealthSafe Inspections Inc
390 Apple Drive
Basalt CO 81621
970-920-2100
Jim Baker
CDPHE Asbestos Building Inspector, Asbestos Air Monitoring Specialist (AMS) &
Project Designer Certification #13437
CDPHE Lead-Based Paint Inspector & Lead Hazard Assessor Certification #23607
ASBESTOS REPORT
DATE
11/29/2017
CLIENT
Owen
c/o Steeplechase Construction, Inc.
0124 Totterdown Rd
Aspen CO 81611
PROJECT PROPERTY ADDRESS
805 Bonita Drive, Aspen, Colorado 81611
For orientation purposes, the front door faces north.
01/05/2018
2
COLORADO & FEDERAL ASBESTOS REGULATIONS SUMMARY
Regulation No. 8 Part B – Asbestos of the Colorado Department of Public Health and
Environment (CDPHE), Air Quality Control Commission requires a State-certified
Asbestos Building Inspector to inspect and collect bulk samples of all suspect asbestos
containing materials (ACM) or suspect asbestos containing building materials (ACBM)
prior to their disturbance, removal or demolition and disposal. The suspect materials shall
be analyzed by a NVLAP accredited laboratory by polarized light microscopy (PLM)
using EPA 600 analytical method. A material which is estimated to contain more than 1%
asbestos is classified as ACM/ACBM and regulated by the State and Federal
governments. Any friable (able to crush or reduce to powder by finger pressure) asbestos
with trace amounts of asbestos fibers or less than 1% must be point-counted using EPA
400 analytical method to prove that it is indeed less than 1%; if not, it must be classified
as ACM/ACBM and shall be treated as a State and Federal regulated material. Any
friable asbestos containing material (greater than 1% asbestos concentration) or
ACM/ACBM that could be rendered friable during its removal or demolition and disposal
shall require an asbestos abatement by a certified asbestos abatement contractor to
remove and dispose of the material(s).
A Colorado State (CDPHE) issued asbestos abatement permit is required for the
following trigger levels of ACM/ACBM:
1. Residential buildings of four or fewer units--if more than 32 square feet of any
surface coverage (e.g., gypsum wallboard or drywall and associated applied surfacing
materials/textures, acoustic sprays, joint compounds, plaster, etc.), 50 feet of asbestos
covered or asbestos insulated pipe or any material which would fill a 55-gallon drum is
going to be disturbed, removed or disposed of, an asbestos abatement permit is required.
2. Residential complexes with more than four residential units, public access areas to a
residential building, commercial and retail buildings, public and civic buildings,
industrial buildings--if more than 160 square feet of surfacing materials, 260 linear feet
or more than 35 cubic feet (NESHAP) or 55-gallon drum (CDPHE) of suspect
ACM/ACBM is going to be disturbed, removed or disposed of, an asbestos abatement
permit is required under NESHAP and by the CDPHE. See note below on OSHA.
The regulations require an absolute minimum of 3 samples (EPA suggests 9) per
homogenous suspect surfacing and TSI materials and an absolute minimum of 1 sample
of homogenous miscellaneous materials or any number of “samples sufficient to
determine whether a material is ACM” (Reg8.IV.D.3). More samples are required based
on surface area or volume. These are minimums; the asbestos building inspector has the
field responsibility to determine homogenous materials and the number of samples to
collect per material; more than the minimum number of samples may be necessary at the
discretion of the inspector. An assessment of friability and functional space conditions of
the materials are also the inspector’s field responsibilities.
01/05/2018
3
OSHA compliance is required for all employers and employees no matter the
quantity of asbestos present with strict regulations regarding 10 sf or more of TSI or
friable surfacing materials, and therefore it does not matter what the quantity or
State trigger levels are: all suspect ACM/ACBM shall be inspected and tested for
asbestos prior to their disturbance, removal and disposal for worker protection and
safety. See EPA 40 CFR 763.121 Worker Protection Rule, OSHA 29 CFR 1910.134
Respirator Protection Standard, OSHA 29 CFR 1910.1001 General Industry Standard and
OSHA 29 CFR 1926.1101 Construction Standard regulations when dealing with asbestos
hazards.
Note: County or City regulations may be more stringent.
CLIENT BACKGROUND
The property owner, Owen, is planning to remodel some of the interior of the west
duplex. Owen hired the general contractor Steeplechase Construction, Inc. (hereinafter,
Steeplechase) to oversee the remodel. Steeplechase hired HealthSafe Inspections, Inc.
(hereinafter, HealthSafe) to perform an asbestos inspection prior to submittal for the
permit for the slated remodel plan.
VISUAL INSPECTION & LABORATORY FINDINGS
An inspection was conducted by Jim Baker of HealthSafe on November 20, 2017 with
Ms. Owen and Steve Waldeck of Steeplechase present during the inspection. Suspect
ACM/ACBM (drywall sheet vinyl flooring materials only) were identified and
sampled. Those materials are the following:
1. A homogeneous taped and joint compounded drywall system (classified as a
miscellaneous material as a complete integral system) [samples 1-2: 805-KDFLT-
J-1,2]; these composite layered taped and joint compounded drywall materials are
on ceilings and walls of the ground-floor areas. The estimated surface area of
impact is more than 32 sf, but less than 1,000 sf, requiring a minimum of at least
two composite core samples of all drywall layers (“…number of samples
sufficient to determine” …if asbestos is present or not). The PLM analytical
estimated results: NONE DETECTED.
2. A homogeneous spray-applied then troweled surfacing material/texture of knock-
down which was then coated at a later date with a flat finish overcoat—
inseparable from the original [samples 3-5: 805-KDFLT-T-1,2,3]. This surfacing
material/texture is on ceilings and walls of the ground-floor areas slated to be
remodeled. The estimated surface area is more than 32 sf, but less than 1,000 sf,
requiring a minimum of at least three surfacing/texture material samples. The
PLM analytical estimated results: NONE DETECTED.
01/05/2018
4
3. Sheet vinyl flooring in the northwest bedroom bathroom, a homogeneous
miscellaneous material requiring at least one sample [sample 6: 805-BTH-
NWBR-SV]. The PLM analytical estimated results: NONE DETECTED.
There were no other additional suspect asbestos building materials to sample which were
slated to be disturbed, removed or disposed of in this remodel. A total of 6 suspect
homogeneous ACM/ACBM bulk samples were collected and 6 samples were analyzed.
The bulk samples were analyzed by PLM by a NVLAP accredited laboratory in
accordance with Colorado State Regulation 8 for the presence of asbestos mineral fibers.
There is NO asbestos in all 6 samples analyzed.
See supporting Hayes Microbial Consulting, Inc. data report #17036646.
HEALTHSAFE CONCLUSIONS
There is NO asbestos in any of the suspect building materials slated to be impacted by
the remodel. NO asbestos abatement will be required. All building materials needing
to be removed or disturbed can be dealt with without the concerns for asbestos fibers. All
building waste and debris can be disposed of in any landfill which accepts normal, non-
hazardous building waste.
Sincerely Submitted,
Jim Baker
01/05/2018
HMC #17036646
contact@hayesmicrobial.com
http://hayesmicrobial.com/
Analysis Report prepared for
HealthSafe Inspections
390 Apple Drive
Basalt, CO. 81621
Phone: 970-920-2100
Job Name: Owen c/o Steeple Chase Construction
805 Bonita Dr
Aspen, CO 81611
Date Sampled: 11-20-2017
Date Analyzed: 11-29-2017
Report Date: 11-29-2017
EPA Laboratory ID# VA01419
NVLAP Lab Code: 500096-0 Asbestos License: 300435 License: #PH-0198
Page 1 of 4
01/05/2018
HMC #17036646
HealthSafe Inspections
390 Apple Drive
Basalt, CO 81621
November 29, 2017
Client Job Number:
Client Job Name:Owen c/o Steeple Chase Construction
805 Bonita Dr
Aspen, CO 81611
Dear HealthSafe Inspections,
We would like to thank you for trusting Hayes Microbial for your analytical needs. On November 22, 2017 we received 6 samples by FedEx for the job
referenced above. 6 samples were received in good condition.
The results in this analysis pertain only to this job, collected on the stated date and should not be used in the interpretation of any other job. This report
may not be duplicated, except in full, without the written consent of Hayes Microbial Consulting, LLC.
This laboratory bears no responsibility for sample collection activities, analytical method limitations, or your use of the test results. Interpretation and
use of test results are your responsibility. Any reference to health effects or interpretation of mold levels is strictly the opinion of Hayes Microbial
Consulting. In no event, shall Hayes Microbial Consulting or any of its employees be liable for lost profits or any special, incidental or consequential
damages arising out of your use of the test results.
Steve Hayes, BSMT(ASCP)
Laboratory Director
Hayes Microbial Consulting, LLC
Page 2 of 4
01/05/2018
HMC #17036646
EPA 600/R-93, M-4/82-020 (PLM)HealthSafe Inspections
390 Apple Drive
Basalt, CO 81621
Phone: 970-920-2100
Job Number:
Collected by:
Email:
Jim Baker
healthsafeinspections@gmail.com
Job Name:Owen c/o Steeple Chase Construction
805 Bonita Dr
Aspen, CO 81611
Date Collected:
Date Received:
Date Reported:
11/20/2017
11/22/2017
11/29/2017
#Sample Name Description Asbestos Fibers Other Fibers Non- Fibers
1 1 805-KDFLT-J-1 Drywall / White
(None Detected)
12 % Cellulose fibers
88 %
Layer 2 805-KDFLT-J-1 Joint Compound / White
(None Detected)
(None Detected)
100 %
2 2 805-KDFLT-J-2 Drywall / White
(None Detected)
3 % Cellulose fibers
97 %
Layer 2 805-KDFLT-J-2 Joint Compound / White
(None Detected)
(None Detected)
100 %
3 3 805-KDFLT-T-1 Texture / White
(None Detected)
2 % Cellulose fibers
98 %
4 4 805-KDFLT-T-2 Texture / White
(None Detected)
2 % Cellulose fibers
98 %
5 5 805-KDFLT-T-3 Texture / White
(None Detected)
2 % Cellulose fibers
98 %
6 6 805-BTH-NWBR-SV Vinyl / White
(None Detected)
(None Detected)
100 %
Signature: Date:11/29/2017 Reviewed by: Date:11/29/2017
Page 3 of 4
01/05/2018
HMC #17036646
Asbestos - Additional InformationHealthSafe Inspections
390 Apple Drive
Basalt, CO 81621
Phone: 970-920-2100
All samples were received in acceptable condition unless otherwise noted on the report. The Report must not be used by the client to claim product certification, approval, or
endorsement by: AIHA, NIST, NVLAP NY ELAP, or any agency. The results relate only to the items tested. The results include an inherent uncertainty of measurement associated with
estimating percentages by polarized light microscopy. Measurement uncertainty data can be provided when requested. None detected: Below the detected reporting limit of 1% unless
point counting is performed, then the detected, reporting limit is .25%. Per NY ELAP198.6 (NOB) TEM is the only reliable method to declare an NOB material as Non-Asbestos
Containing. Hayes Microbial Consulting reserves the right to dispose of all samples after a period of 60 days in compliance with state and federal guidelines.
Signature: Date:11/29/2017 Reviewed by: Date:11/29/2017
Page 4 of 4