Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
File Documents.800 S Mill St.0123.2018 (18).ARBK
SHEET TITLE © COPYRIGHT MILLER & ASSOCIATES, INC 2018 ALL RIGHTS RESERVEDA-0.1 REVISIONDATE ASPEN CONSTRUCTION INC. 208 AABC Aspen CO 81611 d.miller@aciaspen.com 970 379-9331 OF 13SHEET 1 DESIGN DEVELOPMENT2/26/18 HOA REVIEW4/6/18 PERMIT4/12/18 800 S. Mill Street ASPEN CO 81611F:\Dropbox (Personal)\ARCHICAD PROJECTS CURRENT\Projects Current 21.0\5th AVENUE CONDOS\7 5th AVENUE\ARCHICAD FILES 7 5th AVE\7 5TH AVE_8.pln; 8:49 AM 4/20/2018Fifth Avenue Condominiums PROJECT INFORMATION COVER SHEETUnit 7 AFF ABOVE FINISHED FLOOR JCT JUNCTION ACOUS ACOUSTICAL LAM LAMINATE (D) AC ACRE LAV LAVATORY ADD ADDENDA, ADDENDUM LT LIGHT ADJ ADJUSTABLE LL LIVE LOAD ALT ALTERNATE LONG LONGITUDINAL ALUM ALUMINUM MFG MANUFACTURE (D) (R ) AB ANCHOR BOLTS MATL MATERIAL APPD APPROVED MAX MAXIMUM APPROX APPROXIMATE MECH MECHANICAL ARCH ARCHITECTURAL MC MECHANICAL CONTRACTOR ASAP AS SOON AS POSSIBLE MED MEDIC (INE) (AL) BBR BASEBOARD RADIATION MTL METAL BSMT BASEMENT MIN MINIMUM BM BEAM MISC MISCELLANEOUS BRG BEARING NOM NOMINAL BFF BELOW FINISHED FLOOR NA NOT APPLICABLE BET BETWEEN NIC NOT IN CONTRACT BLK BLOCK NTS NOT TO SCALE BD BOARD OC ON CENTER BS BOTH SIDES OPG OPENING BO BOTTOM OF OPP OPPOSITE BF BOTTOM OF FOOTING OPH OPPOSITE HAND BTU BRITISH THERMAL UNIT ORN ORNAMENTAL BLDG BUILDING OSG OUTBOARD SAFETY GLAZING BO BY OWNER OD OUTSIDE DIAMETER CAB CABINET O/ OVER CLG CEILING PTD PAINTED CL Ç CENTER LINE PTN PARTITION CT CERAMIC TILE D PENNY CLR CLEAR PERF PERFORATED CLO CLOSET PITCO PITKIN COUNTY CLD CLOTHES DRYER PLAST PLASTER CLW CLOTHES WASHER PLAS PLASTIC COA CITY OF ASPEN, CO PL PLATE COL COLUMN PLEX PLEXIGLAS CONC CONCRETE PLMB PLUMBING CONN CONNECTION PLY PLYWOOD CONT CONTINUOUS PROJ PROJECT CTR COUNTER PROP PROPERTY CF CUBIC FEET PL ¶ PROPERTY LINE DP DAMP PROOFING QTY QUANTITY DEPT DEPARTMENT QT QUARRY TILE DTL DETAIL R RADIUS DIA DIAMETER REQD REQUIRED DIM DIMENSION RI RISER DW DISHWASHER RD ROOFDRAINROOF DRAIN DBL DOUBLE RM ROOM DWL DOWEL RO ROUGH OPENING DN DOWN RS ROUGH SAWN DR DRAIN SAN SANITARY DWG DRAWING SEC SECTION EA EACH SEW SEWER EW EACH WAY SG SAFETY GLAZING EE EGRESS EXIT SHT SHEET ELECT ELECTRICAL SHLV SHELV (ES) (ING) EC ELECTRICAL CONTRACTOR SIM SIMILAR ELEV ELEVATION SL SLIDING ENGR ENGINEER SD SMOKE DETECTOR EQ EQUAL STC SOUND TRANSMISSION CLASS EXP EXPOSED SPEC SPECIFICATION EXG EXISTING SQ SQUARE EJ EXPANSION JOINT SF SQUARE FEET EXT EXTERIOR SS STAINLESS STEEL FO FACE OF STD STANDARD FIN FINISH STL STEEL FPL FIREPLACE STRUCT STRUCTURAL FP FIREPROOF SUB SUBSTITUTE FIXT FIXTURE S4S SURFACED FOUR SIDES FLR FLOOR SUSP SUSPEND (ED) FD FLOOR DRAIN TEL TELEPHONE FT FOOT, FEET TV TELEVISION FTG FOOTING TEMP TEMPERED FDN FOUNDATION THK THICK FURN FURNISH, FURNITURE TLT TOILET GAL GALLON T&B TOP AND BOTTOM GALV GALVANIZED TO TOP OF GC GENERAL CONTRACTOR T&G TONGUE AND GROOVE GL GLU-LAM TR TREAD GR GRADE TYP TYPICAL GA GAUGE UG UNDERGROUND GYP GYPSUM UNFIN UNFINISHED GWB GYPSUM WALL BOARD UNGL UNGLAZED HDW HARDWARE UBC UNIFORM BUILDING CODE HD HEAD UNO UNLESS NOTED OTHERWISE HT HEIGHT VIF VERIFY IN FIELD HORIZ HORIZONTAL VERT VERTICAL HP HORSE POWER V VOLT ISG INBOARD SAFETY GLAZING VF VENT FAN INCL INCLUDE (D) (ING) VFL VENT FAN W/ LIGHT INFO INFORMATION WC WATER CLOSET IDENT IDENTIFICATION WH WATER HEATER ID INSIDE DIAMETER WP WATERPROOF INSP INSPECT (OR) (ION) WT WEIGHT INSUL INSULATION WWF WELDED WIRE FABRIC INT INTERIOR WDW WINDOW IBC INTERNATIONAL BUILDING CODE W/ WITH IRC INTERNATIONAL RESIDENTIAL CODE W/O WITHOUT JT JOINT WD WOOD JST JOIST WKG WORKING GENERAL NOTES & CONDITIONS 1. The AIA Document A201 “General Conditions of the Contract for Construction”, latest edition, are hereby made a part of these Contract Documents, except as amended herein. Copies are on file and available for inspection at the office of the Architect or Designer. 2. The Contract Documents shall consist of the Agreement, the General Notes & Conditions and the Architectural and, if applicable the Structural Drawings. All future additional specifications, details, drawings, clarifications, or changes shall, in turn, become part of these documents. Work indicated or reasonably implied in any one of the documents shall be supplied as though fully covered in all. Any discrepancy between any parts of the drawings shall be reported to the Architect or Designer immediately for clarification. 3. All work shall comply with all Federal, State, Local and Regional Codes and Ordinances, and shall be performed to the highest standards of craftsmanship by the appropriate trades. 4. Architectural Team waives any and all liability for problems which arise from failure to follow the design intent of the plans. Contractor is to obtain and/or request guidance of Architect or Designer with respect to any errors, omissions, inconsistencies, or conflicts which may be discovered or alleged. 5. The Plans and Specifications are the property of the Architectural or Design Team and are not to be used without express written permission. 6. These Documents are intended to include all labor, materials, equipment and services required to complete all work described herein. These Documents do not indicate the method of construction. It is the responsibility of the Contractor to bring to the attention of the Architect or Designer any conditions which will not permit construction according to the intent of these Documents. Neither the Architect nor Designer shall be responsible for the Contractor’s means, methods, techniques, sequences for procedure of construction, or the safety precautions and the programs incident thereto. The Contractor shall be responsible for all Federal and OSHA regulations. 7. All work shall be erected level, plumb and true to line in accordance with best practices of the trade and manufacturer’s recommendations for the particular item. 8. THESE DRAWINGS SHALL NOT BE SCALED. All written dimensions take precedence over scaled dimensions. Large scaled dimensions take precedence over small scale dimensions. If there is a discrepancy in dimensions, the Architect or Designer shall be notified for clarification. General Contractor shall verify all dimensions with regard to existing conditions. All existing dimensions are to finished materials or center of opening, UNO. All proposed dimensions shall be to face of stud or concrete, UNO. 9. The Building Inspector shall be notified by the Contractor when there is need of inspection as it is required by the International Residential Code/ International Building Code or by any Local Code or Ordinance having jurisdiction. 10. The Contractor shall be responsible for the safety and care of adjacent properties during construction and for compliance with Federal, State and OSHA regulations, and for the protection of all work until it is delivered to the Owner. 11. Contractor shall verify and coordinate all openings and bearings through floors, ceilings, and walls with all Architectural, Structural, Mechanical, Plumbing, Electrical and Lighting Drawings. 12. Contractor will assume responsibility for items requiring coordination and resolution during the bidding process. 13. Where work is installed or existing finishes are disturbed, refinish such areas to match existing conditions. 14. Contractor is to check and verify Contract Documents and field conditions for accuracy, confirming that all work is buildable as shown before proceeding with construction. If there are any questions regarding these or other coordination questions, the Contractor is responsible for obtaining clarification with the Architect or Designer before proceeding with work or related work in question. 15. Each miscellaneous item of cutting, patching or fitting is not necessarily individually described herein. No specific description of cutting, patching, or fitting required to properly accommodate the scope of work shall relieve the Contractor from the responsibility to perform such work as required. 16. HOA covenants and regulations must be abided by at all times. 17. Any questions regarding the intent of the drawings or specifications are to be clarified with the Architect or Designer before ordering materials or proceeding with the work in question or related work. 18. All items are new unless called out as “Existing”. Any recycled members used must be free of defects including cracks, checks & borings and all members must be square and free of cupping, bowing or skewing. 19. Mechanical, plumbing, electrical, fire protection, life safety and low-voltage subcontractors shall provide design/build services in accordance with these documents and their respective specialty and they are responsible for obtaining the permits for their own work. 20. All Change Orders must be authorized by Contractor and Owner in writing to be valid. 21. Typical indicates similar for all conditions, unless noted otherwise. 22. Any changes to demising wall, ceiling or floor finishes where there are penetrations or new partition wall connections, the assembly shall be improved so as to comply with the constraints of 5A type construction as applicable from the unit interior and not from adjacent units. 1/9/2018 Google Maps https://www.google.com/maps/@39.1853359,-106.8195095,569m/data=!3m1!1e3?hl=en 1/1 Imagery ©2018 Google, Map data ©2018 Google 200 ft SHEET INDEX ID A-0.1 A-1.1 A-1.2 A-2.1 A-4.1 A-5.1 A-5.2 A-5.3 A-5.4 A-6.1 A-6.2 A-7.1 A-8.1 Name COVER SHEET FLOOR PLANS FLOOR PLANS SECTIONS DETAILS INT ELEVATIONS INT ELEVATIONS INT ELEVATIONS INT ELEVATIONS FURNITURE PLAN LIGHTING PLAN SCHEDULES EXT ELEVS PROJECT LOCATION Fifth Avenue Condominiums INTERIOR REMODEL VICINITY MAP THE WORK INVOLVES THE INTERIOR REHABILITATION OF THE CONDOMINIUM UNIT. NO WORK SHALL OCCUR OUTSIDE OF THE UNIT, NO STRUCTURAL WORK SHALL OCCUR. THREE WINDOW FRAMES SHALL BE REPLACED AND SHALL HAVE A U-VALUE NO MORE THAN 0.28 AND OVERALL WALL OPENINGS SHALL NOT BE CHANGED. ONE ADDITIONAL FULL BATHROOM SHALL BE ADDED AS WELL AS A LAUNDRY AREA. ALL ADDITIONAL PERMITTING SHALL BE PROVIDED BY SUBCONTRACTORS (I.E. PLUMBING, ELECTRICAL, ETC.). CODE ANALYSIS 800 S. Mill Street ASPEN CO 81611 PROJECT DIRECTORY ARCHITECTURAL ABBREVIATIONS OWNER: 800 MILL 303 LLC 515 W. GILLESPIE STREET ASPEN CO 81611 DESIGNER: ASPEN CONSTRUCTION, INC. DAVID MILLER 208 AABC ASPEN CO 81611 970 379-9331 d.miller@aciaspen.com GENERAL CONTRACTOR: ASPEN CONSTRUCTION, INC. 208 AABC ASPEN CO 81611 970 920-3690 APPLICABLE CODES AS ADOPTED BY CITY OF ASPEN ORDINANCE 40 OF 2016 -2015 INTERNATIONAL BUILDING CODE -2015 INTERNATIONAL PLUMBING CODE -NATIONAL ELECTRIC CODE (MOST CURRENT EDITION) AS PROVIDED BY NFPA AND AMENDMENTS AS ADOPTED BY THE CITY OF ASPEN AS OF DATE OF PLAN SUBMITTAL -2015 INTERNATIONAL MECHANICAL CODE -2015 INTERNATIONAL ENERGY CONSERVATION CODE -2015 INTERNATIONAL FIRE CODE ZONING INFORMATION: N/A - INTERIOR ONLY RESIDENTIAL DESIGN STANDARDS: N/A - INTERIOR ONLY OCCUPANY CLASSIFICATION: R-2 CONSTRUCTION TYPE: TYPE VA 1-HOUR PER 2015 IBC PROPERTY DESCRIPTION LEGAL DESCRIPTION: SUBDIVISION: FIFTH AVENUE UNIT: 7 DECSRIPTION: BUILDING B PARCEL IDENTIFICATION #: 273718276023 FLOOR AREA SUMMARY: 1,072 SF SCOPE OF WORK Unit 7Provide an asbestos abatement clearance report. 04/26/2018 SHEET TITLE © COPYRIGHT MILLER & ASSOCIATES, INC 2018 ALL RIGHTS RESERVEDA-1.1 REVISIONDATE ASPEN CONSTRUCTION INC. 208 AABC Aspen CO 81611 d.miller@aciaspen.com 970 379-9331 OF 13SHEET 2 DESIGN DEVELOPMENT2/26/18 HOA REVIEW4/6/18 PERMIT4/12/18 800 S. Mill Street ASPEN CO 81611F:\Dropbox (Personal)\ARCHICAD PROJECTS CURRENT\Projects Current 21.0\5th AVENUE CONDOS\7 5th AVENUE\ARCHICAD FILES 7 5th AVE\7 5TH AVE_8.pln; 8:49 AM 4/20/2018Fifth Avenue Condominiums FLOOR PLANSUnit 7D10 A A B B D D 11 2 2 3 3 4 4 C C FDW RE 11'-5"14'12'-4"28'-2"3'-4 1/2" 11'-7"3'-4"13'-3"11'-5"14'12'-4"11'-2 1/2" 4 1/2" 3'-4" 4 1/2" 6'-7 1/4" 4 3/4" 5'-10 1/2" 5'-5 3/4" 3 1/2" 5'-9 3/4"3'-8 1/2"3'-7 1/2" 4 1/2" 3'5'-10 1/2" 7 1/2" 3'-3 3/4"4'-1/4" 4 1/2" 3' 4 1/2" 5'-6" 14'-7 1/2" 1'-1/2" 12'-6"12'-3 1/2"4 1/2"2'-2 1/2"1'-4 1/2"4'-1"6 1/2"9'-9"3'-5"4 1/2"1'-11 3/4"2'-11 3/4"3'-1/2"12'-1 1/2"11'-2"4 1/2"2'-3 1/2"3'100'ENTRY FP BALCONY BEDROOM 2 BEDROOM 1 BATH 2 MECHANICAL CL CL SHARED BATH LIVING ROOM KITCHEN CL CL CL OFFICE PANELSHEET NOTES: -DO NOT SCALE DRAWINGS -LARGE SCALE DIMENSIONS HAVE PRECEDENCE OVER SMALL SCALE DIMENSIONS -EXISTING DIMENSIONS ARE TO FACE OF FINISH OR CENTER OF OPENING -PROPOSED DIMENSIONS ARE TO ASSUMED FACE/CENTER OF FRAMING -NOTIFY DESIGN TEAM AS TO STRUCTURAL DIMENSIONS DURING DEMOLITION -NOTIFY DESIGN TEAM AS TO ANY DISCREPANCIES IN DIMENSIONS -ALL DEMISING WALL, CEILING AND FLOOR ASSEMBLIES MUST COMPLY WITH 5A CONSTRUCTION. 1-HOUR FIRE RATED AND STC-50 SOUND RATED. A A B B D D 11 2 2 3 3 4 4 C C FDW RE 100' 0 2'4'8'SCALE: 1/4" = 1'-0"1 EXISTING 0 2'4'8'SCALE: 1/4" = 1'-0"2 DEMOLITION 04/26/2018 06/11/2018 SHEET TITLE © COPYRIGHT MILLER & ASSOCIATES, INC 2018 ALL RIGHTS RESERVEDA-1.2 REVISIONDATE ASPEN CONSTRUCTION INC. 208 AABC Aspen CO 81611 d.miller@aciaspen.com 970 379-9331 OF 13SHEET 3 DESIGN DEVELOPMENT2/26/18 HOA REVIEW4/6/18 PERMIT4/12/18 800 S. Mill Street ASPEN CO 81611F:\Dropbox (Personal)\ARCHICAD PROJECTS CURRENT\Projects Current 21.0\5th AVENUE CONDOS\7 5th AVENUE\ARCHICAD FILES 7 5th AVE\7 5TH AVE_8.pln; 8:49 AM 4/20/2018Fifth Avenue Condominiums FLOOR PLANSUnit 7SHEET NOTES: -DO NOT SCALE DRAWINGS -LARGE SCALE DIMENSIONS HAVE PRECEDENCE OVER SMALL SCALE DIMENSIONS -EXISTING DIMENSIONS ARE TO FACE OF FINISH OR CENTER OF OPENING -PROPOSED DIMENSIONS ARE TO ASSUMED FACE/CENTER OF FRAMING -NOTIFY DESIGN TEAM AS TO STRUCTURAL DIMENSIONS DURING DEMOLITION -NOTIFY DESIGN TEAM AS TO ANY DISCREPANCIES IN DIMENSIONS -ALL DEMISING WALL, CEILING AND FLOOR ASSEMBLIES MUST COMPLY WITH 5A CONSTRUCTION. 1-HOUR FIRE RATED AND STC-50 SOUND RATED. W1 W2 W3 D7 D12 D11 D8 D3 D2 D10 D13 D9 D5 D6 D1 D4 A A B B D D 11 2 2 3 3 4 4 REF RANGE DW C C WW/D 11'-7"3'-4"13'-3"11'-5"14'12'-4"11'-2 3/4"5 1/2"5'-2 3/4"5 1/2"5'-1/4"3 1/2"2'-7 1/2"3 1/2"12'-2 1/2"6 3/4"8'-4"3 1/2"2'-8"3'-1 1/4"1'-3 1/4"2'-3/4"3'-6"3'-6"12'-6 1/2"1'-1"3 1/2"1'-3 1/2"3 1/2"14'-9 1/2"3 1/2"2'-3 1/2"3 1/2"10'-7 1/4" 14'-11 1/4"0 3/4"4'-1"5 1/2"3'-1/2"3 1/2"5'-10 3/4" 11'-3 1/2"3 1/2"3'-4 3/4"3 1/2"12'-11 3/4" 3'-1/2"8'-7"3'-3 3/4"0 3/4"2'-4 1/2"3 1/2"4'-11"3 1/2"5'-10 3/4"7'-1 3/4"3 1/2"2'-1/4"3 1/2"3'-1 1/4"3 1/2"2'-1 1/4"3 1/2"2'-9 1/4"3 1/2"2'-8"3 1/2"8'-5"3 1/2"3'-6"5'-6"3 1/2"1'-7"5 1/2"3'-5 1/2" 2'-5"3 1/2" 1'-3" 3 1/2"9'-6 1/4" 100' W-1A W-2A W-1A W-1A W-2 W-2 W-2 W-2A ENTRY LIVING ROOM KITCHEN FP BALCONY BEDROOM 3 CL 3 CL 1 CL 2 BATH 1BATH 3 PANTRY BEDROOM 2 BEDROOM 1 BATH 2 ISLAND SG/EE SG/EE STORAGE HEARTH MECH COATS WH PANELVENT TO EXTERIOR COMBUSTION AIR FROM EXTERIOR EXHAUST TO EXTERIOR 1 A-2.1 2 A-2.1 A A B B D D 11 2 2 3 3 4 4 C C SD CO SD SD SD VF VF VF CO SD BEDROOM 1 H: 94.00" GUEST 1 BATH H: 84.00" GUEST BEDROOM 2 H: 94.00" GUEST 2 BATH H: 84.00" HALLWAY H: 84.00" KITCHEN H: 84.00" LIVING ROOM H: 94.00"GUEST 3 H: 94.00" GUEST 3 BATH H: 84.00" 1/8"5/8" 5 1/2" 5/8"1/8"1/8"5/8" 5 1/2" 5/8"1/8"1/8"5/8" 3 1/2" 5/8"1/8"1/8"5/8" 3 1/2" 5/8"1/8" 5 1/2" 1 5/8"1 1/4"1/8"1/8"5/8" 3 1/2" 5/8"1/8"1/8"5/8" 3 1/2" 5/8"1/8" W-1 W-1A W-2 W-2A W-3 2X6 EXTERIOR WALL -ALL EXTERIOR WALLS ARE NOT TO BE DISTURBED -INTERIOR IMPROVEMENTS EXCEPTED 2X6 INTERIOR WALL -1/8" PLASTER -5/8" GWB -5 1/2" DF FRAMING @ 16" O.C. -5/8" GWB -1/8" PLASTER 2X4 EXTERIOR WALL -ALL EXTERIOR WALLS ARE NOT TO BE DISTURBED -INTERIOR IMPROVEMENTS EXCEPTED 2X4 INTERIOR WALL -1/8" PLASTER -5/8" GWB -3 1/2" DF FRAMING @ 16" O.C. -5/8" GWB -1/8" PLASTEREXTERIORINTERIORINTERIORINTERIOREXTERIORINTERIORINTERIOR INTERIORPROJECT INTERIORADJACENT INTERIORADJACENT INTERIOR2X6 DEMISING WALL (SEE 1/A-4.1) (5-A CONSTRUCTION REQUIRED) -1/8" PLASTER (INFERED) -5/8" GWB (INFERED) -5 1/2" DF FRAMING @ 16" O.C. (INFERED) WITH SOUND INSULATION BATTS -GENIE CLIP RST WITH RESILIENT CHANNEL @ 48" MAX O.C. HORIZ. AND 24" O.C. VERT -2 @ 5/8" GWB (1-HOUR FIRE RATED) (STC-50 SOUND RATED ASSEMBLY) -1/8" PLASTER -ONLY IMPROVEMENTS ALLOWED ON PROJECT SIDE OF WALL - ENTIRE SURFACE OF WALL MUST COMPLY WITH ASSEMBLYPROJECT INTERIOR2X4/6 DEMISING WALL -1/8" PLASTER (INFERED) -5/8" GWB (INFERED) -3 1/2" / 5 1/2" DF FRAMING @ 16" O.C. (INFERRED) WITH SOUND INSULATION BATTS -5/8" GWB -1/8" PLASTER 0 2'4'8'SCALE: 1/4" = 1'-0"1 PROPOSED 0 2'4'8'SCALE: 1/4" = 1'-0"2 REFLECTED CEILING SCALE: 1:12.00 WALL TYPES If you are altering the hearth extension, demonstrate compliance with all applicable sections of 2015 IBC 2111 and 2113 including the size of the hearth extension and how it is to be supported (Hearth and Extension supported by non-combustible construction. Minimum dimensions: <6 sqft opening: 16” deep, 8” each side. >=6 sqft opening: 20” deep, 12” each side). Indicate vent termination locations and distances from openings, walkways, and property lines. 2015 IMC 501. Provide 100 square inch opening for dryer makeup air in closet (2015 IMC 504.6) 04/26/2018 06/11/2018 SHEET TITLE © COPYRIGHT MILLER & ASSOCIATES, INC 2018 ALL RIGHTS RESERVEDA-2.1 REVISIONDATE ASPEN CONSTRUCTION INC. 208 AABC Aspen CO 81611 d.miller@aciaspen.com 970 379-9331 OF 13SHEET 4 DESIGN DEVELOPMENT2/26/18 HOA REVIEW4/6/18 PERMIT4/12/18 800 S. Mill Street ASPEN CO 81611F:\Dropbox (Personal)\ARCHICAD PROJECTS CURRENT\Projects Current 21.0\5th AVENUE CONDOS\7 5th AVENUE\ARCHICAD FILES 7 5th AVE\7 5TH AVE_8.pln; 8:49 AM 4/20/2018Fifth Avenue Condominiums SECTIONSUnit 7A A B B D D C C +100' MAIN LEVEL +100' MAIN LEVEL +108'-10" UPPER LEVEL +108'-10" UPPER LEVEL 11'-7"3'-4"13'-3" ADJACENT UNIT ADJACENT UNIT ADJACENT UNITHALLBEDROOM 1 BEDROOM 2 4 4 3 3 2 2 1 1 +100' MAIN LEVEL +100' MAIN LEVEL +108'-10" UPPER LEVEL +108'-10" UPPER LEVEL ADJACENT UNIT ADJACENT UNIT ENTRYHALLLIVING SHEET NOTES: -DO NOT SCALE DRAWINGS -LARGE SCALE DIMENSIONS HAVE PRECEDENCE OVER SMALL SCALE DIMENSIONS -EXISTING DIMENSIONS ARE TO FACE OF FINISH OR CENTER OF OPENING -PROPOSED DIMENSIONS ARE TO ASSUMED FACE/CENTER OF FRAMING -NOTIFY DESIGN TEAM AS TO STRUCTURAL DIMENSIONS DURING DEMOLITION -NOTIFY DESIGN TEAM AS TO ANY DISCREPANCIES IN DIMENSIONS -ALL DEMISING WALL, CEILING AND FLOOR ASSEMBLIES MUST COMPLY WITH 5A CONSTRUCTION. 1-HOUR FIRE RATED AND STC-50 SOUND RATED. 0 2'4'8'SCALE: 1/4" = 1'-0"1 SECTION 0 2'4'8'SCALE: 1/4" = 1'-0"2 SECTION 04/26/2018 SHEET TITLE © COPYRIGHT MILLER & ASSOCIATES, INC 2018 ALL RIGHTS RESERVEDA-4.1 REVISIONDATE ASPEN CONSTRUCTION INC. 208 AABC Aspen CO 81611 d.miller@aciaspen.com 970 379-9331 OF 13SHEET 5 DESIGN DEVELOPMENT2/26/18 HOA REVIEW4/6/18 PERMIT4/12/18 800 S. Mill Street ASPEN CO 81611F:\Dropbox (Personal)\ARCHICAD PROJECTS CURRENT\Projects Current 21.0\5th AVENUE CONDOS\7 5th AVENUE\ARCHICAD FILES 7 5th AVE\7 5TH AVE_8.pln; 8:49 AM 4/20/2018Fifth Avenue Condominiums DETAILS DETAILSUnit 748" MAX O.C.1 1/4"1"7/8" GENIECLIP RST SOUND ISOLATING CLIP @ 24" O.C. VERTICAL 3 1/2" / 5 1/2" BATT INSULATION 2X4 / 2X6 EXISTING WOOD STUD SINGLE LAYER OF 5/8" GWB (EXISTING) 7/8" 25 Ga. DRYWALL FURRING CHANNEL 2 LAYERS OF 5/8" GWB DRYWALL FINISH STC-61 [TL07-672] UL RATED [U305]ADJACENT UNITPROJECT UNIT8"24"24"1 1/4"1 5/8"EXISTING 2X FRAMING 3 1/2" BATT INSULATION 2X BLOCKING 2 LAYERS 5/8" GWB GENIECLIP RST SOUND ISOLATING CLIP WITH 7/8" 25 Ga FURRING CHANNEL @ 24" OC 1/4" PERIMETER ACOUTICAL SEALANT 1/2" GAP EXISTING FLOORING DRYWALL FINISH PROJECT UNIT ADJACENT UNIT EXISTING 2X FRAMING EXISTING SUBFLOOR GENIEMAT RST02 SOUND CONTROL UNDERLAYMENT ENGINEERED PRE-FINISHED FLOATING WOOD FLOORING OR CARPETING GENIEMAT PMI PERIMETER ISOLATION STRIP (CONTINUOUS) 3/4" APPLIED WOOD BASE PERIMETER EXPANSION GAP ACCORDING TO FLOORING MFG SPECIFICATIONS PROJECT UNIT ADJACENT UNIT Pliteq 15 GenieClip® 61STC TL07-672 UL Assembly U305 3 1/2" Insulation 3 5/8" Wood Stud 8 3/4" Double Layer 5/8" Gypsum Wallboard Double Layer 5/8" Gypsum Wallboard Wall Assemblies ENGINEERED PARTITIONS NEW WAY with GenieClip RST NEW WAY with GenieClip® RST OLD WAY with 4 Layers OLD WAY with Staggered or Double Studs (Metal or Wood) 3/8” Metal Stud 3 1/2” Insulation 2 x 5/8” Gypsum Wallboard 2 x 5/8” Gypsum Wallboard 2 x 4 Wood Stud 3 1/2” Insulation 2 x 5/8” Gypsum Wallboard 2 x 5/8” Gypsum Wallboard16” max OC8” Double Row of 2 x 4 Wood Stud and 3 1/2” Insulation 5/8” Gypsum Wallboard 5/8” Gypsum Wallboard GenieClip RST 3 1/2” Insulation 7/8” Furring Channel 3 5/8” Metal Stud 5/8” Gypsum Wallboard 5/8” Gypsum Wallboard48” max OC6 1/2” 56STC TL07-620 UL Assembly U419, U423 GenieClip RST 3 1/2" Insulation 3 5/8" Metal Stud 6 1/2"48" max O/C7/8" 25 Ga. Drywall Furring Channel Single Layer 5/8" Gypsum Wallboard Single Layer 5/8" Gypsum Wallboard 56 STC TL07-620 UL Assembly U419, U423 61 STC TL07-672 UL Assembly U305 49 STC TL07-616 UL Assembly U419, U423 47 STC TL11-121 UL Assembly U340 61 STC TL11-120 UL Assembly U341 3 1/2" Insulation 3 5/8" Metal Stud 60STC TL07-617 UL Assembly U419, U423 6 1/8" Double Layer 5/8" Gypsum Wallboard Double Layer 5/8" Gypsum Wallboard 6 1/8” 61STC TL07-672 UL Assembly16” max OC9 1/4” 7 18 "48" max OC2 x 5/8" Gypsum Wallboard GenieClip RST 7/8" Furring Channel 2" x 4" Wood Stud 61STC UL Assembly U305TL07-672 16" max OC3 12 " Insulation 5/8" Gypsum Wallboard48” max OC7 1/8” GenieClip RST 3 1/2” Insulation 7/8” Furring Channel 2 x 4” Wood Stud 5/8” Gypsum Wallboard 2 x 5/8” Gypsum Wallboard 16 Pliteq GenieClip® RETROFIT ASSEMBLIES GENIECLIP® BENEFITS Importance of Engineered Elastomer Isolation Clip Durometer Dynamic Stiffness STC* GenieClip RST 37 11.3 N/mm 57 Isomax™56 21.6 N/mm 57** RSIC-1®57 21.2 N/mm 56 RSIC-V®No Rubber No Rubber 52 *2x4 wood stud 16” OC, 1 layer of 5/8” Type X GWB on each side with 3 1/2” insulation ** Test conducted with 5 1/2” insulation • Increase IIC by 8-12 dB in floor ceiling retrofit assemblies • Increase STC by 12-18 dB in wall retrofit assemblies • Retrofit directly to existing ceiling or wall • Greater STC than other popular retrofit solutions Floor-Ceiling Assembly Wall Assembly Note: Resilient channel failure is a common observation by Acoustical Engineers. Short circuited resilient channel results in up to a 10 STC point reduction. LoVerde, J., & Dong, W. (2009). Quantitative comparisons of resilient channel designs and installation methods. THE GENIECLIP IS PROVEN TO: • Meet building codes for fire and sound • Prevent costly litigation and reconstruction 14" cut around perimeter GenieClip™ Wood Stud 2" Batt Insulation 5/8" Drywall Board 7/8" 25Ga DrywallFurring Channel 1/4" Resilient Fire-Rated Acoustical Caulking Resilient Channel Option Retrofit increases STC 12-18dB GenieClip™ Subfloor Wood Floor Joist 5/8" Drywall Board 2" Batt Insulation 7/8" 25Ga Drywall Furring Channel 1/4" Resilient Fire-Rated Acoustical Caulking Resilient Channel Option 14" cut around perimeter Retrofit increases STC 4-6dB, IIC 8-12dB GenieClip RST Wood Stud Resilient Channel Option 2” Insulation 5/8” Gypsum Wallboard 7/8” Furring Channel Acoustical Sealant Retrofit increases STC 12-18 dB Subfloor Wood Floor Joist Resilient Channel Option (see note) 2” Insulation GenieClip RST 5/8” Gypsum Wallboard 7/8” Furring Channel Acoustical Sealant Retrofit improves STC 4-6 dB, IIC 8-12 1/4” cut around perimeter 1/4” cut around perimeter UL Assembly M523 3” Holes drilled 48” OC GENERAL NOTES:PROJECT: DRAWN BY: DATE: SCALE: NW 2017-08-03 N/A Phone: (416) 449 - 0049 Fax: (416) 849 - 0415 131 Royal Group Crescent Vaughan, ON, L4H 1X9 Canada TEST NO.: GenieClip® RST 6XEPLWWDO'UDZLQJTest Results The information provided in this drawing is accurate to the best of our knowledge at the time of printing. However, we reserve the right to make changes when necessary without notification. 3OLWHT,QF DWG NO.: 1.625" (41.6 mm) CLEARANCE FOR #8 SCREW 2.5" (64.1 mm) 1.875" (48 mm) 1.0" (25 mm)O.C.1/2"5 1/2"1/2"1/4"6 5/8"5/8"44" TYP.DMRZ 1/2" REVEAL OUTLET AT BASEBOARD HARDWOOD FLOORING CARPET 5/8" D BASEBOARD BLOCKING SUBFLOOR Pliteq 7 GenieMat® RST test report number product finish floor structure subfloor ceiling type stc rating (astm e90) iic rating (astm e492) G0535.08 GenieMat® RST02PS Vinyl Plank Open Web Truss 3/4” Gypsum, 3/4” OSB 1/2” RC Deluxe, 5/8” Type C GWB 60 50 G0535.07 GenieMat RST02PS Wood Open Web Truss 3/4” Gypsum, 3/4” OSB 1/2” RC Deluxe, 5/8” Type C GWB 61 50 G0535.01 GenieMat RST02PS Porcelain Tile Open Web Truss 3/4” Gypsum, 3/4” OSB 1/2” RC Deluxe, 5/8” Type C GWB 62 51 F4832.18 GenieMat RST02 Porcelain Tile Engineered Joist 1/2” Plywood, 3/4” OSB GenieClip RST, 2x 5/8” Type C GWB 59 55 F5500.03 GenieMat RST02 Vinyl Plank Engineered Joist 1/2” Plywood, 3/4” OSB GenieClip RST, 2x 5/8” Type C GWB 61 60 F4832.14 GenieMat RST02 Wood Engineered Joist 1/2” Plywood, 3/4” OSB GenieClip RST, 2x 5/8” Type C GWB 58 61 F2761.08 GenieMat RST02 Wood CLT None GenieClip RST, 5/8” Type C GWB 54 50 F2761.09 GenieMat RST12 Porcelain Tile CLT None GenieClip RST, 5/8” Type C GWB 55 51 E5958.07 GenieMat RST05 Vinyl Plank CLT None 12" Wire Suspended on GenieClip LB, 5/8” Type C GWB 58 58 5013143 7013216 GenieMat RST02 Vinyl Plank 2x10 Solid Wood Joist 5/8” Plywood, 1/2” Plywood GenieClip RST, 1/2” Type C GWB 55 50 5013136 7013208 GenieMat RST02 Ceramic Tile 2x10 Solid Wood Joist 5/8” Plywood, 1/2” Plywood GenieClip RST, 1/2” Type C GWB 58 52 acoustical testing standards - wood structures ASTM E2179 - Standard test method for laboratory measurement of the effectiveness of floor coverings in reducing impact sound transmission through concrete floors (6” concrete slab with tile). All listed dimensions are nominal. IMPACT SOUND REDUCTION WHEN INSTALLED BENEATH CERAMIC TILE GenieMat RST12 ½” GenieMat RST10 3/8” GenieMat RST05 3/16” WE Cork ½” GenieMat RST02 5/64” WE Cork ¼” EasyMat™ ½” Whisper Mat® CS 1/8” EasyMat™ ¼” Proflex™ 90MSC 1/8” NobleSeal® SIS 1/16” Protecto-Wrap® 1/8” Mapelastic™ SM 1/16” Super SAM 1/16” 23 dB 21 dB 19 dB 16 dB 18 dB 14 dB 14 dB 12 dB 11 dB 10 dB 9 dB 9 dB 6 dB 4 dB 0 dB 5 dB 10 dB 15 dB 20 dB 25 dB I IC (dB) ASTM E2179 - Standard Test Method for Laboratory Measurement of the Effectiveness of Floor Coverings in Reducing Impact Sound Transmission Through Concrete Floors (6” concrete slab with tile) ∆IIC 0 6''1'2'SCALE: 1" = 1'-0"1 WALL SOUNDPROOFING 0 6''1'2'SCALE: 1" = 1'-0"2 CEILING SOUNDPROOFING 0 6''1'2'SCALE: 1" = 1'-0"3 FLOOR SOUNDPROOFING NOT TO SCALE4PLITEQ TL07-672 WALL ASSEMBLY NOT TO SCALE6PLITEQ RETROFIT ASSEMBLIES NOT TO SCALE5GENIECLIP RST DRAWING 0 3''6''9''SCALE: 3" = 1'-0"8 WALL/BASE REVEAL Z-DETAIL NOT TO SCALE7PLITEQ GENIEMAT RST02 Provide the UL U305 install instructions on the plans Your proposed assembly only has 2 layers of gyp, which does not match the 3 layers of UL M523. Provide a listed assembly on the plans with the full instructions. 04/26/2018 SHEET TITLE © COPYRIGHT MILLER & ASSOCIATES, INC 2018 ALL RIGHTS RESERVEDA-5.1 REVISIONDATE ASPEN CONSTRUCTION INC. 208 AABC Aspen CO 81611 d.miller@aciaspen.com 970 379-9331 OF 13SHEET 6 DESIGN DEVELOPMENT2/26/18 HOA REVIEW4/6/18 PERMIT4/12/18 800 S. Mill Street ASPEN CO 81611F:\Dropbox (Personal)\ARCHICAD PROJECTS CURRENT\Projects Current 21.0\5th AVENUE CONDOS\7 5th AVENUE\ARCHICAD FILES 7 5th AVE\7 5TH AVE_8.pln; 8:49 AM 4/20/2018Fifth Avenue Condominiums INT ELEVATIONSUnit 7+100' MAIN LEVEL +100' MAIN LEVEL +100' MAIN LEVEL +100' MAIN LEVEL +100' MAIN LEVEL +100' MAIN LEVEL +100' MAIN LEVEL +100' MAIN LEVEL 0 1'2'4'SCALE: 1/2" = 1'-0"5 BATH 1 0 1'2'4'SCALE: 1/2" = 1'-0"6 BATH 1 0 1'2'4'SCALE: 1/2" = 1'-0"7 BATH 1 0 1'2'4'SCALE: 1/2" = 1'-0"8 BATH 1 0 1'2'4'SCALE: 1/2" = 1'-0"1 BEDROOM 1 0 1'2'4'SCALE: 1/2" = 1'-0"2 BEDROOM 1 0 1'2'4'SCALE: 1/2" = 1'-0"3 BEDROOM 1 0 1'2'4'SCALE: 1/2" = 1'-0"4 BEDROOM 1 04/26/2018 SHEET TITLE © COPYRIGHT MILLER & ASSOCIATES, INC 2018 ALL RIGHTS RESERVEDA-5.2 REVISIONDATE ASPEN CONSTRUCTION INC. 208 AABC Aspen CO 81611 d.miller@aciaspen.com 970 379-9331 OF 13SHEET 7 DESIGN DEVELOPMENT2/26/18 HOA REVIEW4/6/18 PERMIT4/12/18 800 S. Mill Street ASPEN CO 81611F:\Dropbox (Personal)\ARCHICAD PROJECTS CURRENT\Projects Current 21.0\5th AVENUE CONDOS\7 5th AVENUE\ARCHICAD FILES 7 5th AVE\7 5TH AVE_8.pln; 8:49 AM 4/20/2018Fifth Avenue Condominiums INT ELEVATIONSUnit 7+100' MAIN LEVEL +100' MAIN LEVEL +100' MAIN LEVEL +100' MAIN LEVEL +100' MAIN LEVEL +100' MAIN LEVEL +100' MAIN LEVEL +100' MAIN LEVEL 0 1'2'4'SCALE: 1/2" = 1'-0"1 BEDROOM 2 0 1'2'4'SCALE: 1/2" = 1'-0"2 BEDROOM 2 0 1'2'4'SCALE: 1/2" = 1'-0"3 BEDROOM 2 0 1'2'4'SCALE: 1/2" = 1'-0"4 BEDROOM 2 0 1'2'4'SCALE: 1/2" = 1'-0"5 BATH 2 0 1'2'4'SCALE: 1/2" = 1'-0"7 BATH 2 0 1'2'4'SCALE: 1/2" = 1'-0"8 BATH 2 0 1'2'4'SCALE: 1/2" = 1'-0"6 BATH 2 04/26/2018 SHEET TITLE © COPYRIGHT MILLER & ASSOCIATES, INC 2018 ALL RIGHTS RESERVEDA-5.3 REVISIONDATE ASPEN CONSTRUCTION INC. 208 AABC Aspen CO 81611 d.miller@aciaspen.com 970 379-9331 OF 13SHEET 8 DESIGN DEVELOPMENT2/26/18 HOA REVIEW4/6/18 PERMIT4/12/18 800 S. Mill Street ASPEN CO 81611F:\Dropbox (Personal)\ARCHICAD PROJECTS CURRENT\Projects Current 21.0\5th AVENUE CONDOS\7 5th AVENUE\ARCHICAD FILES 7 5th AVE\7 5TH AVE_8.pln; 8:49 AM 4/20/2018Fifth Avenue Condominiums INT ELEVATIONSUnit 7+100' MAIN LEVEL +100' MAIN LEVEL +100' MAIN LEVEL +100' MAIN LEVEL +100' MAIN LEVEL +100' MAIN LEVEL 0 1'2'4'SCALE: 1/2" = 1'-0"1 KITCHEN/LIVING 0 1'2'4'SCALE: 1/2" = 1'-0"2 KITCHEN/LIVING 0 1'2'4'SCALE: 1/2" = 1'-0"3 KITCHEN/LIVING 0 1'2'4'SCALE: 1/2" = 1'-0"4 KITCHEN/LIVING 0 1'2'4'SCALE: 1/2" = 1'-0"5 BEDROOM 3 0 1'2'4'SCALE: 1/2" = 1'-0"6 BEDROOM 3 04/26/2018 SHEET TITLE © COPYRIGHT MILLER & ASSOCIATES, INC 2018 ALL RIGHTS RESERVEDA-5.4 REVISIONDATE ASPEN CONSTRUCTION INC. 208 AABC Aspen CO 81611 d.miller@aciaspen.com 970 379-9331 OF 13SHEET 9 DESIGN DEVELOPMENT2/26/18 HOA REVIEW4/6/18 PERMIT4/12/18 800 S. Mill Street ASPEN CO 81611F:\Dropbox (Personal)\ARCHICAD PROJECTS CURRENT\Projects Current 21.0\5th AVENUE CONDOS\7 5th AVENUE\ARCHICAD FILES 7 5th AVE\7 5TH AVE_8.pln; 8:49 AM 4/20/2018Fifth Avenue Condominiums INT ELEVATIONSUnit 7+100' MAIN LEVEL +100' MAIN LEVEL +100' MAIN LEVEL +100' MAIN LEVEL +100' MAIN LEVEL +100' MAIN LEVEL +100' MAIN LEVEL +100' MAIN LEVEL +100' MAIN LEVEL +100' MAIN LEVEL 0 1'2'4'SCALE: 1/2" = 1'-0"1 BEDROOM 3 0 1'2'4'SCALE: 1/2" = 1'-0"2 BEDROOM 3 0 1'2'4'SCALE: 1/2" = 1'-0"3 BATH 3 0 1'2'4'SCALE: 1/2" = 1'-0"6 BATH 3 0 1'2'4'SCALE: 1/2" = 1'-0"4 BATH 3 0 1'2'4'SCALE: 1/2" = 1'-0"5 BATH 3 0 1'2'4'SCALE: 1/2" = 1'-0"9 BATH 3 0 1'2'4'SCALE: 1/2" = 1'-0"7 BATH 3 0 1'2'4'SCALE: 1/2" = 1'-0"8 BATH 3 0 1'2'4'SCALE: 1/2" = 1'-0"10 BATH 3 04/26/2018 SHEET TITLE © COPYRIGHT MILLER & ASSOCIATES, INC 2018 ALL RIGHTS RESERVEDA-6.1 REVISIONDATE ASPEN CONSTRUCTION INC. 208 AABC Aspen CO 81611 d.miller@aciaspen.com 970 379-9331 OF 13SHEET 10 DESIGN DEVELOPMENT2/26/18 HOA REVIEW4/6/18 PERMIT4/12/18 800 S. Mill Street ASPEN CO 81611F:\Dropbox (Personal)\ARCHICAD PROJECTS CURRENT\Projects Current 21.0\5th AVENUE CONDOS\7 5th AVENUE\ARCHICAD FILES 7 5th AVE\7 5TH AVE_8.pln; 8:49 AM 4/20/2018Fifth Avenue Condominiums FINISH PLANS FURNITURE PLANUnit 7A A B B D D 11 2 2 3 3 4 4 REF RANGE DW C C WW/D W-1A W-2A W-1A W-1A W-2 W-2 W-2 W-2A 0 2'4'8'SCALE: 1/4" = 1'-0"1 MAIN LEVEL 04/26/2018 06/11/2018 SHEET TITLE © COPYRIGHT MILLER & ASSOCIATES, INC 2018 ALL RIGHTS RESERVEDA-6.2 REVISIONDATE ASPEN CONSTRUCTION INC. 208 AABC Aspen CO 81611 d.miller@aciaspen.com 970 379-9331 OF 13SHEET 11 DESIGN DEVELOPMENT2/26/18 HOA REVIEW4/6/18 PERMIT4/12/18 800 S. Mill Street ASPEN CO 81611F:\Dropbox (Personal)\ARCHICAD PROJECTS CURRENT\Projects Current 21.0\5th AVENUE CONDOS\7 5th AVENUE\ARCHICAD FILES 7 5th AVE\7 5TH AVE_8.pln; 8:49 AM 4/20/2018Fifth Avenue Condominiums FINISH PLANS LIGHTING PLANUnit 7A A B B D D 11 2 2 3 3 4 4 REF RANGE DW C C WW/D MS MS MS MSMS33 3 343343333457" AFF 57" AFF 59" AFF MS MS MS WP WP WP M-1 M-1 M-2 GD MS LIGHTING SCHEDULE MS UNDER CABINET LIGHT SYMBOL DESCRIPTION MANUFACTURER MODEL NUMBER SIZE LAMP WATTS QUANTITY EXHAUST FAN SURFACE MOUNTED CLOSET LIGHT LED RECESSED LIGHT WAC LIGHTING HOUSING HR-3LED-H15D-ICA 3 1/2" APERTURE LED 14.5 WAC LIGHTING LED-T24W-2IN-WT LED 3W/FT3/8" X 1/8" 3PANASONICFV-11VQ5 110 CFM 21 24 LF FLOUR24"616 NONE DECORATIVE LIGHTING TBD TBD TBD TBD 4 SWITCHES TO BE INSTALLED AT 48" CENTERED AFF TYP. 43 ILLUMINATED VANITY MIRROR PARIS MIRROR HARM32323000 32 X 32 X1.6"LED 2 GALA55363000 24 X 36 X 1.6"LED 1ILLUMINATED VANITY MIRROR PARIS MIRROR 54 83 M-1 M-2 Fixture Type: Catalog Number: Project: Location: WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. MAr 2017 waclighting.com Phone (800) 526.2588 Fax (800) 526.2585 Headquarters/Eastern Distribution Center 44 Harbor Park Drive Port Washington, NY 11050 Central Distribution Center 1600 Distribution Ct Lithia Springs, GA 30122 Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760 PRODUCT DESCRIPTION IC-Rated, airtight, new construction housing. For use with HR-3LED Tesla 3.5" Pro and Tesla 3.5" series trims. FEATURES • IC-Rated • Airtight • Cutout: 4s” • 120 - 277 VAC Input • Provided with push-in wire connector for easy installation • Accommodates ceiling thickness from 2”-w" • 5 year WAC Lighting product warranty HR-3LED-H15D-ICA 3.5" Tesla™ New Construction Housing IC-Rated – Airtight SPECIFICATIONS Construction: Housing and junction box are 20 gauge steel. Frame and hanger bars are heavy gauge galvanized steel. J-Box: Seven knockouts and four Romex® style wiring connectors provided for ease of installation. Rated for branch wiring. Driver: Electronic driver, 120 - 277VAC input, 14.5W output. Power factor >0.9 Mounting: Supplied with hanger bars, adjustable between 108"-242 to accommodate various joist construction and grid sizes. Hanger bars include a captive mounting "screw-nail" for ease of installation. Accommodates surfaces from 2”-w" thick. 4s" cutout hole. Dimming: 0-10V Dimming: 100%-0% ELV Dimming: 100%-5% (120V only) Standards: IC-Rated- Suitable for direct contact with insulation. Airtight ETL & cETL Listed. COMPATIBLE TRIMS Allows adjustment in one direction when used with adjustable trims. See individual trim spec sheets for complete order number and specifications HR-3LED-H15D –ICA Example: HR-3LED-H15D-ICA 5s" 6s" 4s" 108" Min 142"Max 242” 31/8” Tesla Pro 3.5"Tesla 3.5" HR3LD-ET118P Series round, High Brightness Wet Location Listed Energy Star® HR3LEDT118P Series round, Downlight Energy Star® HR3LEDT218P Series round, Shower Light Wet Location Listed Energy Star® HR3LEDT718P Series Square, Open reflector Energy Star® HR3LEDT818P Series Square, Shower Light Wet Location Listed Energy Star® HR-3LED-T218 Series round, Shower Light Wet Location Listed HR-3LED-T718 Series Square, Open reflector HR-3LED-T818 Series Square, Shower Light Wet Location Listed HR-3LD-ET118 Series round, High Brightness Energy Star® HR-3LED-T118 Series round. Open reflector Static Pressure (in inches w.g.) 0.1 0.25 Air Volume (CFM) 110 @ 0.1" static pressure 91 @ .25" static pressure Noise (sones) <0.3 @ 110 CFM 0.5 @ 91 CFM Power Consumption (Watts) 21.1 @ 110 CFM 20.7 @ 91 CFM Energy Efficiency (CFM's/Watt) 5.3 @ 110 CFM 4.5 @ 91 CFM Speed (RPM) 950 @ 110 CFM 1161 @ 91 CFM Current (Amps) 0.18 @ 110 CFM 0.17 @ 91 CFM Power Rating (V/Hz) 120/60 Motor Type Condenser Type of Motor Bearing Ball Thermal Fuse Protection Yes Blower Wheel Type Sirocco Duct Diameter (inches) 4" Mounting Opening (inches sq.) 10 1/2" Grille Size (inches sq.) 13" UL Listed for Tub/ Shower Enclosure Yes Washington State VIAQ Code Yes PANASONIC WhisperCeiling™ Fan FV-11VQ5 Quiet, Spot Ventilation Solution, 110 CFM California Title 24 Compliant Yes Mfg in ISO 9001 Certified Facility Yes Energy Star Qualified Yes Dimensions (H x W x D) 10.83'' x 14.17'' x 16.73'' Weight 10.36 lbs UPC885170005617 Fixture Type: Catalog Number: Project: Location: WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. OCT 2017 waclighting.com Phone (800) 526.2588 Fax (800) 526.2585 Headquarters/Eastern Distribution Center 44 Harbor Park Drive Port Washington, NY 11050 Central Distribution Center 1600 Distribution Ct Lithia Springs, GA 30122 Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760 InvisiLED® Pro 24V LED Tape Light 1" 2", 1', 5' sections a" a" 1n" 1n" Tape Section 3 LED "L" Connector PRODUCT DESCRIPTION Professional grade white tape light that delivers optimal color consistency and brightness. An ideal system for task or accent lighting applications. FEATURES • Ultra thin pro le at 8" • Diodes spaced evenly at 1" on center • Minimum run length of 1' • May be eld cut every 2" at the end of a run • Three mounting methods provided for di erent surfaces • Specially rated for installation in the storage area of a clothes closet • 50,000 hour rated life • 5 year WAC Lighting product warranty LED-T24___-3L-WT Example: LEDT24C3LWT LED-T24___-______-WT Example: LEDT24P2IN10WT ORDER NUMBER TAPE SECTION Model Watts/ft Color Temp CRI Lumens/ft Length Qty Tape Color LEDT24 3 W P 35 C 2700K 3000K 3500K 4500K 85 85 85 85 200 200 207 215 2IN 2IN10 1 140 5 2 inches 2 inches 1 foot 1 foot 5 feet 1 10 1 40 1 WT White ORDER NUMBER 3 LED "L" CONNECTOR Model Watts Color Temp CRI Lumens Tape Color LEDT24 1.2 W P 35 C 2700K 3000K 3500K 4500K 85 85 85 85 50 50 52 54 3L-WT White SPECIFICATIONS Construction: Power Supply: Light Source: Dimming: Operating Temp: Standards: Flexible, silicone cased tape light. Peel and stick 3M construction adhesive on back. Indicating marks on back for eld cutting. Remote and plug-in electronic Class 2 transformers. 120VAC 50/60Hz input, 24V 60W and 96W output. 12 LEDs per foot May be dimmed with electronic low voltage (ELV) dimmer. -4°F - 122°F (-20°C - 50°C), relative humidity 95%. UL & CUL Listed for damp locations. Type Model Input Output Max Run Dim Remote EN2460RB2T EN24100RB2T 120VAC 120VAC 24VAC / 60W 24VAC / 96W 20 feet 33 feet ELV ELV Includes a 6 foot lead wire Plug-in EN2460PART EN24100PART 120VAC 120VAC 24VAC / 60W 24VAC / 96W 20 feet 33 feet ELV ELV Includes a 6 foot lead wire Remote 277V EN24100277RB2T 277VAC 24VDC / 96W 33 feet 0-10V Includes a 6 foot lead wire Class 2 Power Supply (Required) 24V LED Tape Light Paris Mirror Technical Data Sheet Product Name : ILLUMINATED MIRROR HARMONY 32 In X 32 In SKU : HARM32323000/HARM32326000 FEATURES • LED TECHNOLOGY • HANG HORIZONTALLY - VERTICALLY • ENERGY EFFICIENT • SUPER BRIGHT • DIMMABLE • UL CERTIFIED • DURABLE ( UP TO 120 000 HOURS ) • 5 YEARS WARRANTY • MADE IN CANADA Paris Mirror ELECTRIC SPECS • Dimensions : 32x32 in • Weight : 33 pounds (LBS) • IP rating: 44 • Watts: 54 • Lumens: 5040 • Input Voltage: 110V • CRI: 90+ Front Profile Back 31.4"31.4"32"32"29.1" 26.8"29.1"26.8"1.6"31.4"1.2" 1.2" 30.9"30.9"0.2" Aluminum Frame Frosted glass Paris Mirror INSTALLATION INSTRUCTION: Installation: All Paris Mirror backlit and LED mirrors have been independently tested for compliance with electrical equipment (safety) regulations. All illuminated and backlit mirrors are IP44 rated. Illuminated mirrors have been designed and independently tested for compliance to electrical equipment (safety) regulations, and are UL Certified. LED’s have a life expectancy of 120,000 hours of continuous use. All LED light fittings are replaceable and are available through Paris Mirror customer service. IMPORTANT: Always switch off the electrical supply at the mains during installation and maintenance. It is recommended that fuse is withdrawn or circuit breaker switched off before installation begins. Fitting in Bathrooms is subject to all regulations. It is not suitable for product installations in Saunas, Steam Rooms, or shower cubicles, and it is recommended for permanent installation. Care Safety: Wear suitable eye wear protection when drilling. Use caution when using power tools near water, beware of hidden cables or pipes. Take care if drilling on tiled surfaces in case the drill slips. A piece of masking tape applied to wall before marking out fixing holes will stop drill from moving. Cleaning & Maintenance: It is recommended that the unit is cleaned with a soft, dry, non-abrasive cloth when turned off. Never use cleaning agents or abrasive material on any type of surface finish. Do not strike glass components with hard or pointed items. Do not place very hot or cold items against or close proximity to glass surfaces. 1- Decide on wall positional placement.2- Prepare & install wall hooks measured to distance between mirror’s anchors. 3- Match & attach 3 electrical wires from mirror to home electrical wires: Live to Live, Ground to Ground, Neutral to Neutral.4- Hang and affix to wall. INSTALLATION & AFTER CARE INSTRUCTIONS: 120V, Dimmable Led Driver included Position 1: 3 0 , 9 ” Paris Mirror Technical Data Sheet Product Name : ILLUMINATED MIRROR GALAXY 55 In X 36 In SKU : GALA55363000/GALA55366000 FEATURES • LED TECHNOLOGY • HANG HORIZONTALLY - VERTICALLY • ENERGY EFFICIENT • SUPER BRIGHT • DIMMABLE • UL CERTIFIED • DURABLE ( UP TO 120 000 HOURS ) • 5 YEARS WARRANTY • MADE IN CANADA Paris Mirror ELECTRIC SPECS • Dimensions : 55x36 in • Weight : 50 pounds (LBS) • IP rating: 44 • Watts: 83 • Lumens: 7740 • Input Voltage: 110V • CRI: 90+ Front Profile Back 1,6" FrameAluminum36"3 feet wire 54,7" 54,2"36"36"55" 52,6"33,6"1,2"Frosted glass Paris Mirror INSTALLATION INSTRUCTION: Installation: All Paris Mirror backlit and LED mirrors have been independently tested for compliance with electrical equipment (safety) regulations. All illuminated and backlit mirrors are IP44 rated. Illuminated mirrors have been designed and independently tested for compliance to electrical equipment (safety) regulations, and are UL Certified. LED’s have a life expectancy of 120,000 hours of continuous use. All LED light fittings are replaceable and are available through Paris Mirror customer service. IMPORTANT: Always switch off the electrical supply at the mains during installation and maintenance. It is recommended that fuse is withdrawn or circuit breaker switched off before installation begins. Fitting in Bathrooms is subject to all regulations. It is not suitable for product installations in Saunas, Steam Rooms, or shower cubicles, and it is recommended for permanent installation. Care Safety: Wear suitable eye wear protection when drilling. Use caution when using power tools near water, beware of hidden cables or pipes. Take care if drilling on tiled surfaces in case the drill slips. A piece of masking tape applied to wall before marking out fixing holes will stop drill from moving. Cleaning & Maintenance: It is recommended that the unit is cleaned with a soft, dry, non-abrasive cloth when turned off. Never use cleaning agents or abrasive material on any type of surface finish. Do not strike glass components with hard or pointed items. Do not place very hot or cold items against or close proximity to glass surfaces. 1- Decide on wall positional placement.2- Prepare & install wall hooks measured to distance between mirror’s anchors. 3- Match & attach 3 electrical wires from mirror to home electrical wires: Live to Live, Ground to Ground, Neutral to Neutral.4- Hang and affix to wall. INSTALLATION & AFTER CARE INSTRUCTIONS: 120V, Dimmable Led Driver included Position 1: 3 5 , 5 ” Position 2: 5 4 , 2 ” 0 2'4'8'SCALE: 1/4" = 1'-0"1 MAIN LEVEL WAC 3.5 Inch LED IC Panasonic FV-11VQ5 WAC InvisiLED Pro Paris LED Harmony Mirror 1 Paris LED Harmony Mirror 2 Paris LED Harmony Mirror 3 Paris LED Galaxy Mirror 1 Paris LED Galaxy Mirror 2 Paris LED Galaxy Mirror 3 Note the requirement for all penetrations of the rated ceiling to have 1 hour fire rated protection. This includes can lights, ventilation fans, vents, etc. Dryer vent must be 26 gauge and have the annular space protected. (2015 IBC 714. 04/26/2018 SHEET TITLE © COPYRIGHT MILLER & ASSOCIATES, INC 2018 ALL RIGHTS RESERVEDA-7.1 REVISIONDATE ASPEN CONSTRUCTION INC. 208 AABC Aspen CO 81611 d.miller@aciaspen.com 970 379-9331 OF 13SHEET 12 DESIGN DEVELOPMENT2/26/18 HOA REVIEW4/6/18 PERMIT4/12/18 800 S. Mill Street ASPEN CO 81611F:\Dropbox (Personal)\ARCHICAD PROJECTS CURRENT\Projects Current 21.0\5th AVENUE CONDOS\7 5th AVENUE\ARCHICAD FILES 7 5th AVE\7 5TH AVE_8.pln; 8:49 AM 4/20/2018Fifth Avenue Condominiums SCHEDULESUnit 7DOOR AND FRAME SCHEDULE DOOR MARK D1 D2 D3 D4 D5 D6 D7 D8 D9 D10 D11 D12 D13 SLAB SIZE W 2'-6" 5' 2' 2'-6" 3' 2'-4" 2'-4" 2'-8" 1'-9" 2'-6" 4' 2'-4" 2' HT 6'-8" 6'-8" 6'-8" 6'-8" 6'-8" 6'-8" 6'-8" 6'-8" 6'-8" 6'-8" 6'-8" 6'-8" 6'-8" THK 0'-1 3/4" 0'-1 3/4" 0'-1 3/4" 0'-1 3/4" 0'-1 3/4" 0'-1 3/4" 0'-1 3/4" 0'-1 3/4" 0'-1 3/4" 0'-1 3/4" 0'-1 3/4" 0'-1 3/4" 0'-1 3/4" DOOR TYPE SOLID CORE INT. SOLID CORE INT. SOLID CORE INT. SOLID CORE INT. SOLID CORE INT. SOLID CORE INT. SOLID CORE INT. SOLID CORE INT. SOLID CORE INT. SOLID CORE INT. SOLID CORE INT. SOLID CORE INT. SOLID CORE INT. DETAIL JMB THK 1 1/2" SOLID 1 1/2" SOLID 1 1/2" SOLID 1 1/2" SOLID 1 1/2" SOLID 1 1/2" SOLID 1 1/2" SOLID 1 1/2" SOLID 1 1/2" SOLID 1 1/2" SOLID 1 1/2" SOLID 1 1/2" SOLID 1 1/2" SOLID JAMB 4 7/8" 4 7/8" 4 7/8" 4 7/8" 4 7/8" 6 7/8" 4 7/8" 4 7/8" 4 7/8" 4 7/8" 4 7/8" 4 7/8" 4 7/8" SILL NO NO NO NO NO NO NO NO NO NO NO NO NO SLAB SINGLE RIGHT HAND BIFOLD PAIR SINGLE RIGHT HAND SINGLE LEFT HAND BIFOLD POCKET SINGLE LEFT HAND SINGLE LEFT HAND SINGLE LEFT HAND SINGLE LEFT HAND BIFOLD PAIR SINGLE RIGHT HAND SINGLE LEFT HAND HARDWARE PRIV/PASS PRIVACY NONE PRIVACY PRIVACY NONE PRIVACY PRIVACY PASSAGE PASSAGE PRIVACY NONE PRIVACY PRIVACY MANUFACTURER ROOM BEDROOM 1 CLOSET 1 BATHROOM 1 BEDROOM 2 CLOSET 2 BATHROOM 2 BATHROOM 2 MECHANICAL COAT CLOSET BEDROOM 3 CLOSET 3 BATHROOM 3 BATHROOM 3 WALL THK 4.75" 4.75" 4.75" 4.75" 4.75" 6.75" 4.75" 4.75" 4.75" 4.75" 4.75" 4.75" 4.75" WINDOW SCHEDULE MARK W1 W2 W3 SIZE WIDTH 1'-10" 3'-4" 1'-11" HEIGHT 4'-2" 5'-10" 5'-10" TYPE CASEMENT CASEMENT CASEMENT MANUFACTURER PELLA PELLA PELLA NOTES OPERATIVE CASEMENT SAFETY GLAZED EGRESS CASEMENT WINDOW SAFETY GLAZED CASEMENT WINDOW U-VALUE 0.28 0.28 0.28 EXTERIOR MATCH EXISTING MATCH EXISTING MATCH EXISTING INTERIOR PINE PINE PINE 1" SOLID JAMB 1/4" SHIM SPACE "Z" REVEAL DRMZ-625-50 TAPE & JOINT COMPOUND APPLIED STOP SOLID CORE DOOR (SEE SCHEDULE) 5/8" DRYWALL DOOR AND FRAME SCHEDULE WINDOW SCHEDULE 0 3''6''9''SCALE: 3" = 1'-0"1 DOOR REVEAL Z-DETAIL 04/26/2018 SHEET TITLE © COPYRIGHT MILLER & ASSOCIATES, INC 2018 ALL RIGHTS RESERVEDA-8.1 REVISIONDATE ASPEN CONSTRUCTION INC. 208 AABC Aspen CO 81611 d.miller@aciaspen.com 970 379-9331 OF 13SHEET 13 DESIGN DEVELOPMENT2/26/18 HOA REVIEW4/6/18 PERMIT4/12/18 800 S. Mill Street ASPEN CO 81611F:\Dropbox (Personal)\ARCHICAD PROJECTS CURRENT\Projects Current 21.0\5th AVENUE CONDOS\7 5th AVENUE\ARCHICAD FILES 7 5th AVE\7 5TH AVE_8.pln; 8:49 AM 4/20/2018Fifth Avenue Condominiums RDS REVIEW EXT ELEVSUnit 7Residential Design Standards Exemption Form Exemption Applies Notes Remodel of a structure where the alterations proposed change the exterior of the building, but are not addressed by any of the Residential Design Standards Residential unit within a mixed-use building Designated historic resource listed on the Aspen Inventory of Historic Landmark Sites and Structures Has already received a board design approval Disclaimer: This exemption is only valid for the attached scope of work. If the project scope ex- pands to include work subject to Residential Design Standards, the applicant shall be required to apply for an Administrative Compliance Review. Address: Parcel ID: Zone District/PD: Representative: Email: Phone: Scope of Work: Reviewed by: (Project plans/elevations attached) 4 A8.1 Replacement of existing windows with operative/safety glazing/egress. Sarah Yoon Digitally signed by Sarah Yoon Date: 2018.04.17 11:31:43 -06'00' elevation with no change to size or shape of opening. no change to size or shape of opening. (1) window replaced on the west (2) windows replaced on the south elevation of unit #7 with 970-379-9331 d.miller@aciaspen.com David Miller Lodge (L) / Aspen Mountain PD 2737-182-76-023 800 S. Mill Street #7 RDS EXEMPTION APPROVAL EXISTING WINDOW W1 FIXED UNIT 20" X 50" EXISTING WINDOW W3 OPERATIVE UNIT 21" X 70" EXISTING WINDOW W2 0.28 U FIXED UNIT 40" X 70" PROPOSED WINDOW W1 0.28 U OPERATIVE UNIT 20" X 50" PROPOSED WINDOW W3 OPERATIVE S.G. UNIT 21" X 70" PROPOSED WINDOW W2 0.28 U OPERATIVE E.E./S.G. UNIT 40" X 70" EXISTING WEST ELEVATION EXISTING SOUTH ELEVATION W1 W2W3 800 S. MILL ST. #7 04/26/2018 06/11/2018