ASBESTOS ABATEMENT CLEARANCE REPORT
DATE
05/22/2018
CLIENT
800 S Mill 303, LLC.
c/o Matt Brown
515 W Gillespie Ave
Aspen CO 81611
PROJECT PROPERTY ADDRESS
800 South Mill Street, Fifth Avenue Condominium #7, Aspen, Colorado 81611
For orientation purposes, the front door faces south.
CLIENT BACKGROUND
The Client, 800 S Mill 303, LLC., hired HealthSafe Inspections, Inc. (hereinafter,
HealthSafe) to perform a post-abatement clearance for asbestos containing sheet vinyl
flooring which was abated, that is, removed entirely from the kitchen and adjacent
bathroom. This required an asbestos abatement permit from CDPHE (Permit Notice
#18P12525A dated 04/30/2018) and a certified asbestos abatement. Prestige
Environmental Services, Inc. provided the asbestos abatement and called for the
abatement clearance inspection and PCM air sampling once their abatement of the sheet
vinyl flooring layers was completely removed and disposed of.
2
VISUAL INSPECTION & LABORATORY FINDINGS
An asbestos post-abatement visual clearance inspection and PCM air sampling was
conducted by Jim Baker of HealthSafe on Friday May 18, 2018. The visual clearance
verified that all friable sheet vinyl flooring had been completely removed from the
plywood subflooring in the kitchen and adjacent bathroom. All debris was removed and
the remaining subfloor was virtually dust-free. No further abatement, removal or cleaning
procedures were required.
Following the visual clearance, clean rotary vane sampling pumps were warmed up for 5-
10 minutes and site calibrated. A box fan was deployed at a 45°angle off the east wall of
the bathroom and the containment area blown with a leaf blower as required by the
regulations for clearances. PCM samples were set in locations to represent the
distribution of air throughout the containment-abatement space. A trip blank and two field
blanks, opened for 30 seconds, were included in the batch of five PCM air samples, but
were not required to be analyzed by the laboratory.
3
HEALTHSAFE PCM LABORATORY DATA
The five PCM air samples at total volumes between 930 and 941 liters of air all had less
than 0.005 fibers detected (<0.005 f/cc) per cubic centimeter of air. This well below the
0.01 f/cc level for clearance.
See attached Hayes laboratory report #18015520.
CONCLUSIONS
Based on the visual post-abatement verification clearance inspection and based on the
post-abatement PCM air sample data, the containment area of the dining and bathrooms
spaces has fully passed abatement clearance.
The containments and equipment can be disassembled and removed. Repairs and/or
remodeling can commence at once.
Sincerely Submitted,
Jim Baker
S t4AI'
o Li—
S I o F V
/�.'i�
1:33
iO.ba
3s-
HMC #18015520
contact@hayesmicrobial.com
http://hayesmicrobial.com/
Analysis Report prepared for
HealthSafe Inspections
390 Apple Drive
Basalt, CO. 81621 USA
Phone: 970-920-2100
Job Name: C/O Matt Brown
800 S. Mill St., #7
Aspen, CO 81611
Date Sampled: 05-18-2018
Date Analyzed: 05-21-2018
Report Date: 05-21-2018
EPA Laboratory ID# VA01419
NVLAP Lab Code: 500096-0 Asbestos License: 300435 License: #PH-0198
Page 1 of 4
HMC #18015520
HealthSafe Inspections
390 Apple Drive
Basalt, CO 81621 USA
May 21, 2018
Client Job Number:
Client Job Name:C/O Matt Brown
800 S. Mill St., #7
Aspen, CO 81611
Dear HealthSafe Inspections,
We would like to thank you for trusting Hayes Microbial for your analytical needs. On May 21, 2018 we received 5 samples by FedEx for the job
referenced above. 5 samples were received in good condition.
The results in this analysis pertain only to this job, collected on the stated date and should not be used in the interpretation of any other job. This report
may not be duplicated, except in full, without the written consent of Hayes Microbial Consulting, LLC.
This laboratory bears no responsibility for sample collection activities, analytical method limitations, or your use of the test results. Interpretation and
use of test results are your responsibility. Any reference to health effects or interpretation of mold levels is strictly the opinion of Hayes Microbial
Consulting. In no event, shall Hayes Microbial Consulting or any of its employees be liable for lost profits or any special, incidental or consequential
damages arising out of your use of the test results.
Steve Hayes, BSMT(ASCP)
Laboratory Director
Hayes Microbial Consulting, LLC
Page 2 of 4
HMC #18015520
Asbestos PCM AnalysisHealthSafe Inspections
390 Apple Drive
Basalt, CO 81621 USA
Phone: 970-920-2100
Job Number:
Collected by:
Email:
Jim Baker
healthsafeinspections@gmail.com
Job Name:C/O Matt Brown
800 S. Mill St., #7
Aspen, CO 81611
Date Collected:
Date Received:
Date Reported:
05/18/2018
05/21/2018
05/21/2018
page1
HMC ID Number: 18015520 - 4 Sample Media: Air - Asbestos
Sample ID Number: 04 Sample Name: SE Bath
Sample Volume Fiber Count Fibers/mm2 Fibers/CC Notes
930.00 1 / 100 <0.005
HMC ID Number: 18015520 - 5 Sample Media: Air - Asbestos
Sample ID Number: 05 Sample Name: Clst
Sample Volume Fiber Count Fibers/mm2 Fibers/CC Notes
930.00 1 / 100 <0.005
HMC ID Number: 18015520 - 6 Sample Media: Air - Asbestos
Sample ID Number: 06 Sample Name: Hlwy
Sample Volume Fiber Count Fibers/mm2 Fibers/CC Notes
940.00 1 / 100 <0.005
HMC ID Number: 18015520 - 7 Sample Media: Air - Asbestos
Sample ID Number: 07 Sample Name: Kit
Sample Volume Fiber Count Fibers/mm2 Fibers/CC Notes
940.00 1 / 100 <0.005
HMC ID Number: 18015520 - 8 Sample Media: Air - Asbestos
Sample ID Number: 08 Sample Name: NE Bath
Sample Volume Fiber Count Fibers/mm2 Fibers/CC Notes
941.00 1 / 100 <0.005
Signature: Date:05/21/2018 Reviewed by: Date:05/21/2018
Page 3 of 4
HMC #18015520
Asbestos - Additional InformationHealthSafe Inspections
390 Apple Drive
Basalt, CO 81621 USA
Phone: 970-920-2100
All samples were received in acceptable condition unless otherwise noted on the report. The Report must not be used by the client to claim product certification, approval, or
endorsement by: AIHA, NIST, NVLAP NY ELAP, or any agency. The results relate only to the items tested. The results include an inherent uncertainty of measurement associated with
estimating percentages by polarized light microscopy. Measurement uncertainty data can be provided when requested. None detected: Below the detected reporting limit of 1% unless
point counting is performed, then the detected, reporting limit is .25%. Per NY ELAP198.6 (NOB) TEM is the only reliable method to declare an NOB material as Non-Asbestos
Containing. Hayes Microbial Consulting reserves the right to dispose of all samples after a period of 60 days in compliance with state and federal guidelines.
Signature: Date:05/21/2018 Reviewed by: Date:05/21/2018