Loading...
HomeMy WebLinkAboutFile Documents.614 North St.0248.2017 (39).ARBKStanding Seam Metal Roofing www.mbci.com | shop.mbci.com 05-17 HOUSTON | 281.407.6915 ADEL, GA | 888.514.6062 ATLANTA | 678.337.1619 ATWATER, CA | 209.445.3891 ENNIS, TX | 469.256.8255 INDIANAPOLIS | 317.364.4329 LUBBOCK, TX | 806.224.2724 MEMPHIS, TN | 662.298.2337 OKLAHOMA CITY | 405.492.6968 PHOENIX | 480.630.3022 ROME, NY | 315.371.4330 SALT LAKE CITY | 385.715.2952 SAN ANTONIO | 210.888.9768 Features and Benefits: • Narrower widths, heavier gauges, striations and embossing minimize oil canning. • Panels can be installed on roofs with a transition by using MBCI’s die-formed rib covers. • Numerous UL 580 Construction rating are available, as well as UL 790, Class A for external fire, numerous roof assemblies for UL 263 for internal fire and the UL 2218 Class 4 impact rating. • LokSeam® carries Florida approval rating. Product Specifications • Applications: Roof • Coverage Widths: 12", 16", 18" • Minimum Slope: 3:12 • Panel Attachment: Concealed Fastening System, Standard and UL90 Clips • Gauges: 24 (standard); 22 (12", 16", 18"), 26 (12") (optional) • Finishes: Striated (standard); Embossed Striated (optional) • Coatings: Galvalume Plus®, Signature® 200, Signature® 300, Signature® 300 Metallic LokSeam® is a snap-together standing seam roof system with a 1 3/4" tall vertical rib, for use on roofs with a minimum slope of 3:12. LokSeam® panels are available in 12-inch, 16-inch and 18-inch widths. LokSeam® panels can be installed over open framing or a solid substructure and are capable of transitioning from roof to fascia with the use of a rib cover. LokSeam® does not require a solid substructure for support. STANDING SEAM METAL ROOFING LOKSEAM® 2/27/2018 Descriptions and specifications contained herein were in effect at the time this publication was approved for printing. In a continuing effort to refine and improve products, MBCI reserves the right to discontinue products at any time or change specifications and/or designs without incurring obligation. To ensure you have the latest information available, please inquire or visit our website at www.mbci.com. Application details are for illustration purposes only and may not be appropriate for all environmental conditions, building designs or panel profiles. Projects should be designed to conform to applicable building codes, regulations and accepted industry practices. If there is a conflict between this manual and project erection drawings, the erection drawings will take precedence. MBCI’s insulated metal panel product line is manufactured by Metl-Span®.05-17 CATEGORY CHARACTERISTIC TEST METHOD PURPOSE RESULT ENVIRONMENTAL Impact Resistance UL 2218 Determines Impact Resistance of prepared Roof Covering Materials Class 4 Rating FIRE RESISTANCE Room Fire Performance UL 790 Standard for Standard Test Methods for Fire Tests of Roof Coverings See Class A Fire Rating Data Sheet Room Fire Performance UL 263 Standard for Fire Tests of Building Construction and Materials For use in Design Nos. P225, P227, P230, P237, P265, P268, P508, P510, P512, P701, P711, P720, P722, P726, P731, P734, P801, P815, P819. STRUCTURAL Uplift Resistance ASTM E 1592 Provides a standard procedure to evaluate or confirm structural performance under uniform static air pressure difference See Load Chart Section Gravity Loads AISI S100 North American Specification for the Design of Cold-Formed Steel Structural Members See Section Properties and Allowable Load Table Section ROOF LISTINGS Roof Performance Underwriters Laboratories UL 580 Determines the uplift resistance of roof assemblies consisting of the roof and roof coverings materials Class 90 Rating - Construction Number 254, 255, 261, 303, 342, 343, 414, 436, 445, 446, 447, 448, 486, 508A, 543 and 544. Roof Performance Florida Approval ASTM E 1592 UL 790 Florida product approval is the approval of products and systems, which comprise the building envelope and structural frame, for compliance with the structural requirements of the Florida Building Code. See FL# 11819.3 Roof Performance Texas Department of Insurance UL 580 TWIA provides windstorm and hail insurance in areas exposed to hurricanes and currently provides windstorm and hail coverage in the following 14 “first tier” Texas coastal counties: Aransas, Brazoria, Calhoun, Cameron, Chambers, Galveston, Jefferson, Kenedy, Kleberg, Matagorda, Nueces, Refugio, San Patricio and Willacy. See RC-61 LOKSEAM® STANDING SEAM METAL ROOFING 2/27/2018