Loading...
HomeMy WebLinkAboutFile Documents.614 North St.0248.2017 (35).ARBKBuildingComment1 The condensing units mentioned in the narrative should be shown on your elevations and site plan. 614 W North Aspen Design Narrative 9-14-17.pdf (1) Subject: PlanCheck Page Label: 6 Author: justinh File Name: Architectural Permit Set.614 W North St.2017.10.pdf FP Response: Gas and electric meters are not being moved. Utility meters are now shown on all site plans. REF: Keynote 22 on A-001, A-201X, A-201 and A-202. Are the gas and electric meters being moved? There are not shown here on proposed plan where they were located on the existing site plan. Please show the utility meters on the proposed plan and in the elevations. Architectural Permit Set.614 W North St.2017.10.pdf (32) Subject: PlanCheck Page Label: 9 Author: justinh File Name: Architectural Permit Set.614 W North St.2017.10.pdf Provide total gross area (exterior+ interior) for both the existing and proposed tables. FP Response: Total gross area has been provided in both the existing and proposed gross area floor calculation legends. REF: A-004X and A-004. Subject: PlanCheck Page Label: 10 Author: justinh File Name: Architectural Permit Set.614 W North St.2017.10.pdf Stairways are not excluded in your gross area measurements. FP Response: Both existing and proposed gross area calculations include stairways. Graphics for gross area plans have been updated. REF: A-004X and A-004. Heating, ventilating and air-conditioning The HVAC system in the residence will consist of the following. Fan Coils for cooling and supplemental heating and radiant floor heating for 1st stage of heating. The lower level will have radiant heating installed in the floors. No supplemental heat would be required for this level. A 300 CFM heat recovery ventilator will be required for this level to provide for ventilation. Ducts will be routed from the toilet rooms for exhaust and supply to each room with a small 4” supply duct. Exhaust and outside air will be taken in and/or exhausted through a wall vent. The main level will have radiant heating and a fan coil installed. The fan coil will be approximately 2,000 CFM and have a 4 ton condensing unit on the exterior of the building for cooling. The fan coil will have 4 zones on the main level for separate control. The fan coil shall be variable speed on a VFD so it does not require a bypass damper. The radiant floor will be the 1st stage of heating. The fan coil shall have a heating water coil installed to cover the outside make up air necessary for the kitchen hood as well as enough load to make the air temperature from the fan coil reach 95 degrees in the winter. The condensing unit shall be a minimum 16 SEER similar to the Lennox XC16. The fan coil will be similar to the Lennox CBWMV model sized correctly for the coil and CFM. The upper level will have radiant heating and a fan coil installed. The fan coil will be approximately 1,400 CFM and have a 3 ton condensing unit on the exterior of the building for cooling. The fan coil will have 4 zones on the upper level for separate control. The fan coil shall be variable speed on a VFD so it does not require a bypass damper. The radiant floor will be the 1st stage of heating. The condensing unit shall be a minimum 16 SEER similar to the Lennox XC16. The fan coil will be similar to the Lennox CBWMV model sized correctly for the coil and CFM. The in-floor radiant heating shall be piped at 10” on center piping at ½” in the floor. Each zone and loop shall be routed to manifold boxes at select locations on each level. The boiler system described above shall have pumps for each system for injection pumping, different water temperatures and controls. The domestic water system shall have a priority call when it is in need of boiler water, it will be first priority and will drive the temperature of the heating water system. Exhaust fans will be installed at all toilet room locations to provide code required exhaust in those locations. Grilles, Registers and diffusers will be floor and/or ceiling as required in the spaces. The registers will be installed as near to the outside walls as possible. Linear grilles shall be 10/11/17 The condensing units mentioned in the narrative should be shown on yourelevations and site plan. 10'-0" 40 3 57 PROPERTY LINE5' REAR SETBACK LINER YARD BACK TRASH Are the gas and electric meters being moved? There are not shown here on proposed plan where they were located on the existing site plan. Please show the utility meters on the proposed plan and in the elevations. D C APROPERTY LINESETBACK LINEE B LOWER LEVELMAIN LEVELUPPER LEVEL GROSS INTERIOR: GARAGE MAIN LEVEL PORCHUPPER LEVEL DECK GROSS EXTERIOR: 1,131.50 SF1,180.50 SF1,281.00 SF 3,593.00 SF 228.25 SF 102.00 SF69.50 SF 171.5 SF TOTAL EXISTING GROSS AREA The floor area within the inside perimeter of the exterior walls ofthe building under consideration, exclusive of vent shafts andcourts, without deduction for corridors, stairways, closets, thethickness of interior walls, columns or other features. The floorarea of a building, or portion thereof, not provided withsurrounding exterior walls shall be the usable are under thehorizontal projection of the roof or floor above. The gross floorarea shall not include shafts with no openings or interior courts. Commentary: Gross floor are is that area measured within theperimeter formed by the inside surface of the exterior walls. Thearea of all occupiable and non-occupiable spaces, includingmechanical and elevator shafts, toilets, closets, mechanical IRC - FLOOR AREA GROSS DEF. EXTERIOR COVERED AREA DECK Provide total gross area (exterior + interior) for both the existing and proposed tables. 2 3 4 D C A 1 1,529.00 sq ft PROPERTY LINE SETBACK LINE SETBACK LTYP.E B 319.00 sq ft 3 4 5 6 D C A 1,293.25 sq ft 228.25 sq ft PROPERTY LINE SETBACK LINE PROPERTY LINE SETBACK LINE PROPERTY LINE5' REAR SETBACK LINE10' REAR SETBA CK LINE E B SCALE: 1/8" = 1'-0" PROPOSED LOWER LEVEL GROSS AREA PLAN04'8'16'AN Stairways are not excluded in your grossarea measurements. Subject: PlanCheck Page Label: 2 Author: justinh File Name: 614 W North Aspen Design Narrative 9-14-17.pdf FP Response: Condensing units that were specified in the mechanical narrative are now shown in plan and elevation. REF: A-001, A-201, & A-202 2/27/2018 Subject: PlanCheck Page Label: 10 Author: justinh File Name: Architectural Permit Set.614 W North St.2017.10.pdf FP Response: All proposed gross area plans have been updated showing covered and uncovered patios correctly. The total proposed gross interior area, including the covered front porch and upper level deck is 4,696 SF, which is under 5,000 gross SF. Fire sprinklers are not required for this residence. REF: A-004X and A-004. Per your legend these areas are covered exterior areas but they are not per the site plans. Please revise this sheet to correctly show covered areas and revise the proposed gross area table as needed. If the total proposed gross is over 5,000 SF then fire sprinklers will be required to be installed in all areas where ceilings coverings are being removed/altered and the fire service water line must be installed. If that is the case a plan showing where sprinklers will be installed in the home will be required as well as the civil plans for the required water line installation if your current service line is not sufficient. Section B makes this area look like it may be filled in but detail 5/502 calls out crawlspace, please clarify. If this is crawlspace show the required crawlspace access per R408.4. These measurements should be made to the face of the exterior veneer to give the true dimension of the window well area, not face of existing wood framing as the grid line you are measuring to is labeled. Please revise for all emergency escape window wells. Subject: PlanCheck Page Label: 19 Author: justinh File Name: Architectural Permit Set.614 W North St.2017.10.pdf Provide the full installation instructions for this gas appliance. FP Response: Full installation instructions for the Montigo Gas Fireplace have been provided. REF: Monitgo Gas Fireplace HLB34 Installation Instructions. 2 2 3 3 4 4 D C A 1 1 1,529.00 sq ft PROPER T Y LI N E SETBACK LINE SETBTYP.E B 319.00 sq ft 2 2 3 3 4 4 5 5 6 6 D D C C A A 1 1 1,293.25 sq ft 228.25 sq ft 337.00 sq ft PROPERTY LINE SETBACK LINE PROPER TY LI NE SETBACK LIN E PROPERTY LINE SETBACK LINE PROPE R TY LIN E 5' REAR S E TBAC K LINE10' REAR S ETBA C K LINE E E B B 1,285.50 sq ft 2 3 4 D C A 1 145.00 sq ft PROPER T Y LI N E SETB ACK LINE SETB E B LOWER LEVELMAIN LEVELUPPER LEVELGROSS INTERIOR: GARAGEMAIN LEVEL PATIOUPPER LEVEL DECK GROSS EXTERIOR: 1,529.00 SF1,293.25 SF1,285.50 SF4,107.75 SF 228.25 SF656.00 SF145.00 SF 801 SF TOTAL PROPOSED GROSS AREA The floor area within the inside perimeter of the exterior walls ofthe building under consideration, exclusive of vent shafts andcourts, without deduction for corridors, stairways, closets, thethickness of interior walls, columns or other features. The floorarea of a building, or portion thereof, not provided withsurrounding exterior walls shall be the usable are under thehorizontal projection of the roof or floor above. The gross floorarea shall not include shafts with no openings or interior courts. Commentary: Gross floor are is that area measured within theperimeter formed by the inside surface of the exterior walls. Thearea of all occupiable and non-occupiable spaces, includingmechanical and elevator shafts, toilets, closets, mechanicalequipment rooms, etc., is included in the gross floor area. Thisarea could also include any covered porches, carports or otherexterior space intended to be used as part of the building'soccupiable space. IRC - FLOOR AREA GROSS DEF. FIRE AREA The aggregate floor are enclosed and bounded by fire walls, firebarriers, exterior walls, or horizontal assemblies of a building.Areas of the building not provided with surrounding walls shall beincluded in the fire area if such areas are included within thehorizontal projection of the roof or floor next above. EXTERIOR COVERED AREA DECK SCALE: 1/8" = 1'-0" PROPOSED LOWER LEVEL GROSS AREA PLAN04'8'16'SCALE: 1/8" = 1'-0" PROPOSED MAIN LEVEL GROSS AREA PLAN SCALE: 1/8" = 1'-0"PROPOSED UPPER LEVEL GROSS AREA PLAN Per your legend these areas are covered exterior areas but theyare not per the site plans. Please revise this sheet to correctlyshow covered areas and revise the proposed gross area table asneeded. If the total proposed gross is over 5,000 SF then firesprinklers will be required to be installed in all areas where ceilingscoverings are being removed/altered and the fire service water linemust be installed. If that is the case a plan showing wheresprinklers will be installed in the home will be required as well asthe civil plans for the required water line installation if your currentservice line is not sufficient. 001A 004A 003A W-2 W-6 8"10'-93/4"31/2"5'-21/2"31/2"15'-6"7'-113/8"31/2"3'-41/4" 11'-71/8" 15'-65/8" 1'-6"1'-6"40'-91/4"33'-51/4"T.O. CONC.91'-0" T.O. FF91'-2" BA-302 42 26 52 51 SD CO SD SD SETBACK LINE16'-3 5/8"11'-10 5/8"6 7/8"BEDROOM 2 003 BEDROOM 1001 BATH 2004 AA-301 B C Section B makes this area look like it may be filled in but detail 5/502 calls out crawlspace, please clarify. If this is crawlspace show the required crawlspace access per R408.4.003004W-6 W-1 W-2 7'-7"8"4'-10"8"2'-3"8"8" 15'-43/4"31/2"8'-101/2"33'-51/4"8'-11"5'-6"2'-11"3'-0"7'-7"T.O. CONC.91'-0" T.O. FF91'-2"2626 27 9 PROPERTY LINE SETBACK LINE GRID TO EXTERIOR FACE OFEXISTING WOOD FRAMING GRID TO EXTERIOR FACE OFEXISTING WOOD FRAMING BEDROOM 3008 AA-301 3A-201 E D 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 SAFETY GL RADON VEN EXISTING H VERTICAL M STANDING S SYNTHETIC EMERGENCPER IRC R3 DWELLING-PER IRC R3 BARS, GRILESCAPES A LINE OF EX DRIVEWAY EXTERIOR D HANDRAIL P GUTTER SNOW STO PANEL TO B& REQUIRE SEWAGE EJ ELECTRICA DOWNSPOU PROPOSED FLAT ROOF, LIGHTWELLSNOWMELT DWELLING-PENETRATI GAS + ELEC ROOF OVER GLASS GUASUPPORT P DRYER FLU LINE OF FO These measurements should be made to the face of the exterior veneer to give the true dimension of the window well area, not face of existing wood framing as the grid line you are measuring to is labeled. Please revise for all emergency escape window wells. 114115 113 W-43'-310'-051/2"2'-10"51/2"9'-11/4"4'-65/8"T.O. PLY100'-0" T.O. FF100'-2" 9 27 28 29 57 MONTIGO GAS FIREPLACE:H SERIES HLB34 LINEAR BURNER LIVING RO 107 Provide the full installation instructions for this gas appliance. Subject: PlanCheck Page Label: 18 Author: justinh File Name: Architectural Permit Set.614 W North St.2017.10.pdf FP Response: Grid 6 is referencing the main level framing above. For clarification, enlarged plans of the lightswells have been provided with dimensions to the exterior veneer. REF: A-101 & A-402. Subject: PlanCheck Page Label: 18 Author: justinh File Name: Architectural Permit Set.614 W North St.2017.10.pdf FP Response: This area will be utilized as conditioned space. Our initial submittal showed a crawl space, which was unpractical to construct, as there is existing space below grade currently. Detail number has been updated from 5/502 to 4/502. REF: A-101X, A-101, A-302, A-502 2/27/2018 Subject: PlanCheck Page Label: 19 Author: justinh File Name: Architectural Permit Set.614 W North St.2017.10.pdf On the detail for W3 you note that W3 are existing walls being refinished and re-insulated, that is not the case here as these are completely new walls in these locations. Revise these references on all floor plans, sections, details, etc. Provide a detail for the new exterior walls and be sure to demonstrate how the required continuous air barrier will be tied into the existing air barriers in the existing walls. Also be sure to demonstrate how this are barrier will transition to differing materials such as where it ties to the foundation and roof. Subject: PlanCheck Page Label: 21 Author: justinh File Name: Architectural Permit Set.614 W North St.2017.10.pdf Show your section grid lines on the roof plan. FP Response: Section markers have been made visible. REF: A-104. Subject: PlanCheck Page Label: 21 Author: justinh File Name: Architectural Permit Set.614 W North St.2017.10.pdf Snow stops are required in this location as well as this sheds onto the upper level deck. FP Response: A snow stop has been add to the section of roof above the upper level deck. REF: Keynote 35 on A-104 and A-201. Subject: PlanCheck Page Label: 21 Author: justinh File Name: Architectural Permit Set.614 W North St.2017.10.pdf Identify all roof penetrations and venting terminations on the roof plan, both DV gas appliances as well as the radon vent termination should be shown. Subject: PlanCheck Page Label: 21 Author: justinh File Name: Architectural Permit Set.614 W North St.2017.10.pdf Overflow scuppers or secondary drains are required per R903.4.1. FP Response: Overflow drain to be provided on West side of deck per IRC R903.4.1. REF: A-103115103 116 101B 101A 117102101W-6 W-6 W-3 W-3 W-6BA-302 4'-2"3'-77/8"25'-31/8"51/2"3'-81/2"51/2"3'-23/8"51/2"5'-05/8"31/2"1'-87/8"31/2"16 33'-51/4"10'-01/4"3'-31/2"16'-10"9'-11/4"51/2"2'-10"51/2"16'-41/2"51/2"1'-11"1'-91/2"5'-6"4'-0"4'-65/8"27'-103/4"15'-81/4"31/2"5'-113/8"31/2"4'-51/4"31/2"5'-67/8"2'-31/2"6'-5"31/2"4'-11/4"31/2"3'-41/2"4'-11"4'-11"3'-2"1'-6"1'-6"T.O. PLY100'-0" T.O. FF100'-2" AA-301 1A-201 LINE OF ROOFABOVE LINE OF WALLABOVE 27 9 28 29 5 53 53 57 ROPERTY LINEGRID TO EXTERIOR FACEOF NEW WOOD FRAMINGGRID TO EXTERIOR FACE OFEXISTING WOOD FRAMINGGRID TO EXTERIOR FACE OFEXISTING WOOD FRAMING2'-4 5/8"'-10 5/8"PORCH PATIO PWDR102 ENTRY101 W-3 E D B C 5'-0"31/2"4'-11/4"31/2" WINE On the detail for W3 you note that W3 are existing walls being refinished and re-insulated, that is not the case hereas these are completely new walls in these locations. Revise these references on all floor plans, sections,details, etc. Provide a detail for the new exterior walls and be sure to demonstrate how the required continuous airbarrier will be tied into the existing air barriers in theexisting walls. Also be sure to demonstrate how this are barrier will transition to differing materials such as where itties to the foundation and roof. PROPERTY LINEShow your section grid lines on the roof plan. 51 UPPER LEVELDECK BELOW 12:12 12:1212:12 12:12 12:12 12:12 1:12 1:12 33 33 35 35 Snow stops are required in this location as well as this sheds onto the upper level deck. 8"81/8" 35 38 23 Identify all roof penetrations and venting terminations on the roof plan, both DV gas appliances as well as the radon vent termination should be shown. 1A-201 17'-4"16'-17/8"1'-21/8"8 3'-5 8 9'-4 51 UPPER LEVELDECK BELOW E D 1:12 1:12 14 33 33 35 35 Overflow scuppers or secondary drains are required per R903.4.1. FP Response: A new assebmly W-4 has been added to the project on sheet A-501. This assembly has continuous insulation on the exterior. W-5 has also been updated to have continuous insulation on the exterior. All floor plans, sections, and details have been updated to show these revised assemblies. Detail 11 on Sheet A-502 demonstrates the connection between the existing stud wall and propsed wall with continous insulation. REF: A-102, A-103, A-301, A-302, A-303, A-501, A-502 FP Response: All roof penetrations and venting terminations have been located. REF: A-104 2/27/2018 Subject: PlanCheck Page Label: 22 Author: justinh File Name: Architectural Permit Set.614 W North St.2017.10.pdf Show all venting terminations on your elevations (dryer exhaust, bath fans, etc.). Be sure they comply with the requirements of IMC 501.3.1 for exhaust termination location. Subject: PlanCheck Page Label: 22 Author: justinh File Name: Architectural Permit Set.614 W North St.2017.10.pdf Window fall protection required per R312.2.1, note this requirement on either the window schedule or elevation and provide a cutsheet for the opening control device. FP Response: Window fall protection will be provided per R312.2.1 on windows 208, 209, and 210. REF: A-201,A-202, A-601, & A-602 Subject: PlanCheck Page Label: 23 Author: justinh File Name: Architectural Permit Set.614 W North St.2017.10.pdf Subject: PlanCheck Page Label: 25 Author: justinh File Name: Architectural Permit Set.614 W North St.2017.10.pdf This is not the correct wall reference per the floor plan. FP Response: Wall tag has been updated to reflect the correct assembly. REF: A-101, A-301, and Detail W-1 on A-501. Subject: PlanCheck Page Label: 25 Author: justinh File Name: Architectural Permit Set.614 W North St.2017.10.pdf This is not the correct wall reference per your floor plan. W1 does not meet the prescriptive insulation requirements for a basement wall. FP Response: Wall tag has been updated to reflect the correct assembly. All existing foundation walls are either being demolished or underpinned. REF: A-101, A-301 and Detail W-2 on A-501. E D SETBACK LINET.O. EXISTING RIDGE"PROPERTY LINEShow all venting terminations on your elevations (dryer exhaust, bath fans, etc.). Be sure they comply with the requirements of IMC 501.3.1 for exhaust termination location. 35 38 46 37 43 40 18 210 55 61 SGWindow fall protection required per R312.2.1, note this requirement on either the window schedule or elevation and provide a cutsheet for the opening control device. 105 207 208 106 209 35 37 10 38 9 28 58 60 29 SG SG Window fall protection required per R312.2.1, note this requirement on either the windowschedule or elevation and provide a cutsheet for the opening control device. W-2 1 A-502 3 A-502 EXISTING LOWER LEVEL T.O. CONC. 91'-0" EXISTING MAIN LEVEL T.O. PLY 100'-0" = 7891'-9" 68 69 70 71 72 73 74 75 76 77 78 79 This is not the correct wall reference per the floor plan. W-1 1 A-502 This is not the correct wall reference per your floor plan. W1 does not meet the prescriptive insulation requirements for a basement wall. Window fall protection required per R312.2.1, note this requirement on either the window schedule or elevation and provide a cutsheet for the opening control device. FP Response: Window fall protection will be provided per R312.2.1 on windows 208, 209, and 210. REF: A-201, A-202, A-601, & A-602 FP Response: All venting terminations have been located and labeled in the elevation drawings. REF: A201-, A-202, & A-202. 2/27/2018 Subject: PlanCheck Page Label: 25 Author: justinh File Name: Architectural Permit Set.614 W North St.2017.10.pdf Reference a detail for the garage ceiling that shows the required dwelling separation between the garage and the bedroom above. Include that reference on section B as well. FP Response: Existing floor structure to remain. Ceiling finish to be replaced with Type C Gyp. REF: A-301, 500-A, & F-4 on A-501 Subject: PlanCheck Page Label: 25 Author: justinh File Name: Architectural Permit Set.614 W North St.2017.10.pdf This reference is incorrect, W2 is a concrete foundation wall. Please revise. FP Response: Wall tag has been updated to reflect the correct assembly. REF: A-102, A-301, & W-4 on A-501. Subject: PlanCheck Page Label: 26 Author: justinh File Name: Architectural Permit Set.614 W North St.2017.10.pdf Incorrect reference for a basement wall. FP Response: Wall tag has been updated to reflect the correct assembly. REF: A-102, A-302, and Detail W-2 on A-501. Subject: PlanCheck Page Label: 26 Author: justinh File Name: Architectural Permit Set.614 W North St.2017.10.pdf Incorrect reference for your basement wall. FP Response: Wall tag has been updated to reflect the correct assembly. REF: A-102, A-302, & W-2 on A-501. Subject: PlanCheck Page Label: 26 Author: justinh File Name: Architectural Permit Set.614 W North St.2017.10.pdf This is not an existing wall. FP Response: Wall tag has been updated to reflect the correct assembly. REF: A-102, A-302, & W-4 on A-501. N GARAGE 107W-5 A-502 8A-502 R-1 105/8"209 EXISTING EXISTING UPPE10'-111/2"Reference a detail for the garage ceiling that shows the required dwelling separation between the garage and the bedroom above. Include that reference on section B as well. ENTRY 101 BEDROOM 2 W-2 7A-502 6A-502 R-2 F-3 This reference is incorrect, W2 is a concrete foundation wall. Please revise. W-1 1 A-502 5 A-502 EXISTIN Incorrect reference for a basement wall. W-1 A-502 1A-502 Incorrect reference for your basement wall. W-3 4 A-502 EXISTING UPPER LEVEL T.O. PLY 109'-6" EXISTING UPPER LEVEL STEP This is not an existing wall. 2/27/2018 Clearly show the handrails on the details for each level and show compliant terminations or continuity between levels. These details do not show it well and I cannot tell if it is intended to be continuous between levels or terminate at each landing. Subject: PlanCheck Page Label: 28 Author: justinh File Name: Architectural Permit Set.614 W North St.2017.10.pdf Open risers must restrict the opening to 4" where 30" or more above the floor below. FP Response: Open risers have been revised to restrict openings to 3 5/8". REF: A-401. Subject: PlanCheck Page Label: 30 Author: justinh File Name: Architectural Permit Set.614 W North St.2017.10.pdf Subject: PlanCheck Page Label: 30 Author: justinh File Name: Architectural Permit Set.614 W North St.2017.10.pdf Provide documentation that your proposed roof/roof deck assemblies are class A (UL listing, ESR report, etc.). Subject: PlanCheck Page Label: 31 Author: justinh File Name: Architectural Permit Set.614 W North St.2017.10.pdf Not an existing wall per where this is referenced on section B. FP Response: Wall tag has been updated to reflect the correct assembly. REF: A-102, A-302, Detail W-4 on A-501, and Intersection Detail 5 onA-502. 111 6'-01/4" 2'-111/4"11/2"2'-111/2"75/8"9'-61/4"14 R @ 7 3/4" = 9'-0" DNUP 3'-11"11"EA-401 EA-401 009A 11"3'-0"1/4"3'-0" UP TYP.EA-401 201B 205A 2'-111/4"11/2"2'-111/2"10'-55/8"DN 14 R @ 7 3/4" = 9'-0"11"MASTER CLO 2 EA-401 75/8"45/8"3/4"43/4"5'-51/2" 11/2" 21/2"77/8"4'-15/8"4"CLOSED STAIR OPEN RISERW/ WOOD TREADS STEEL STRINGER STEEL HANDRAILPER CODE (TYP) STEEL HANDRAILPER CODE (TYP)TYP.YP.4'-51/2"2"15'-8"0 1'2'4'SCALE: 1/2" = 1'-0"2 MAIN LEVEL STAIR 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 WILDLIFE-RESISTANT TRASH ENCLOSURE PER26.575.020.E.5.t BUILDING CONNECTION PER 26.575.020.F.4.a SAFETY GLAZING RADON VENT PIPE EXISTING HORIZONTAL WOOD SIDING TO BE REPAINTED VERTICAL METAL SIDING TBD STANDING SEAM ROOF SYNTHETIC SHINGLE EMERGENCY ESCAPE AND RESCUE DOORSPER IRC R310.3 DWELLING-GARAGE FIRE SEPARATIONPER IRC R302.6 BARS, GRILLS, COVERS, SCREENS OVER EMERGENCYESCAPES AND RESCUE OPENING PER RDS 310.4 LINE OF EXTERIOR WALL BELOW DRIVEWAY TO REMAIN EXTERIOR DECK MATERIAL TBD HANDRAIL PER IRC 311.7.8 & 311.7.8.1 MIN HEIGHT 34" AC UNITS GUTTER SNOW STOPS / SNOW FENCE PANEL TO BE NON-LOCKING FLIP-UP GRATE& REQUIRE NO MORE THAN 15 LBS OF FORCE TO OPEN SEWAGE EJECTOR ACCESS LOCATION ELECTRICAL PANEL LOCATION DOWNSPOUT PROPOSED GRADE FLAT ROOF, SLOPED 1/4" PER 1' FOR DRAINAGE LIGHTWELL MINIMUM OPENING AREA PER IRC R310.2.1SNOWMELT PER IRC 310 LIFE & SAFETY DWELLING-GARAGE OPENING ANDPENETRATION PROTECTION PER IRC R302.5 GAS + ELECTRIC METERS ROOF OVERHANG GLASS GUARD SAFETY GLAZED PER IRC 308.4 &SUPPORT POINT LOAD PER IRC 301.5 DRYER FLUE VENT; TYP LINE OF FOUNDATION BELOW FALL PROTECTION PROVIDED PER R612.2 1/4" PER 1' SLOPE GAS LANTERNS BEVOLO CONTEMPORARY SERIES ASPHAULT SHINGLES TO BE REPLACED BRICK TO MATCH PAVER TBD LINE OF PROPOSED GRADE 2" CURB TYP. HOSE BIB LADDER AND STEPS PER IRC R310.2.3.1 1/2 POINT FROM EAVE TO RIDGE 1/3 POINT FROM EAVE TO RIDGE RADON VENT PIPE ID 01 02 03 CO PRO DRA DAT 04 Clearly show thehandrails on the detailsfor each level andshow compliantterminations orcontinuity betweenlevels. These detailsdo not show it well andI cannot tell if it isintended to be continuous betweenlevels or terminate ateach landing. 205A75/8"45/8"4'-15/8"4"OPEN RISER W/ WOOD TREADS STEEL STRINGER STEEL HANDRAIL PER CODE (TYP)TYP.Open risers must restrict the opening to 4" where 30" or more above the floor below. PER PLAN W-3 ER EXT PER PLAN W-4 EXTERIOR WOOD WALL W/ MASONRYR-21 BRICK AIR SPACE SPRAY APPLIED CLOSED CELL FOAM INSULATION; R-6.25 PER 1" DRAINAGE MAT GYP FELT BUILDING PAPER WATER RESISTIVE BARRIER SHEATHING REF STRUCT F-2 E F-3 DECK OVER CONDITIONED SPACER-50 This detail does not meet the prescriptive insulation requirements of a wood frame exterior wall.2"FINI CON SCR RIG VAP T.O.SLAB CEILING PER PLAN FINISH FLOOR PER PLANS WARMBOARD SHEATHING REF STRUCT EXISTING JOIST TO REMAIN VERIFY IN FIELD SOUND INSULATION T.O.SUBFLOOR R-1 T.O.SHEATHING SLOPE PERPLAN EXISTING ASPHALT SHINGLE ROOFR-49 CLASS A RATED UNDERLAYMENT FULLY ADHERED ROOF MEMBRANE SHEATHING REF STRUCT SPRAY APPLIED CLOSED CELL FOAM INSULATION;R-6.25 PER 1" RAFTER REF STRUCT CEILING PER PLAN STANDING SEAM STANDING SEAM METAL ROOFR-49R-2 T.O.SHEATHING SLOPE PERPLAN FINISH MATERIAL PER PLAN TAPERED RIGID INSULATION SPRAY APPLIED CLOSED CELL FOAMINSULATION; R-6.25 PER 1" JOIST PER STRUCT. DRAINAGE MAT 5/8" GYP SHEATHING RE: STRUCTURAL WATERPROOF MEMBRANE Provide documentation that your proposedroof/roof deck assemblies are class A (UL listing, ESR report, etc.). F-2 W-3 FF-1 PRESSURE TREATED SILL PLATRE: STRUCTURAL LEDGER RE: STRUCTURAL EXTERIORINTERIOR = 1'-0" & EXTERIOR WALL TRANSITION Not an existing wall per where this is referenced on section B. Subject: PlanCheck Page Label: 28 Author: justinh File Name: Architectural Permit Set.614 W North St.2017.10.pdf FP Response: All stair details have been revised to better illustrate the handrails with their continuity and terminations. REF: A-401. This detail does not meet the prescriptive insulation requirements of a wood frameexterior wall. FP Response: W-4 and W-5 assemblies have been updated to meet the prescriptive insulation requirements of a wood framed wall. REF: Detail W-4 and Detail W-5 on A-501. FP Response: Documentation has been provided showing that the roof/roof deck assemblies are class A. REF: A-501 & Specification sheets provided for each assembly. 2/27/2018 Subject: PlanCheck Page Label: 31 Author: justinh File Name: Architectural Permit Set.614 W North St.2017.10.pdf Not showing a continuous air barrier. Lower wall (W3) is incorrect as that is not an existing wall per the floor plans. FP Response: Wall tag has been updated to reflect the correct assembly. REF: A-102, A-302, Detail W-4 on A-501, and Intersection Detail 7 on A-502. In multiple details, sections, and on the floor plans you are making reference to W3 for an existing exterior wall where that is not the case. These two details are new exterior walls per where they are being referenced in the sections and need to be referenced correctly and consistently throughout your plans. The majority of south exterior wall is new. Make sure these incorrect references are corrected throughout your plan set. Provide a detail for the new exterior walls being proposed. All new exterior walls need to show a continuous air barrier to be tied into the existing construction, foundation, and roof construction and meet the residential insulation requirements. This door must meet the requirements of R302.5.1 as a opening between the garage and residence. Call out the compliant material or fire rating of the door and note the requirement for a self- closing device. Subject: PlanCheck Page Label: 34 Author: justinh File Name: Architectural Permit Set.614 W North St.2017.10.pdf Per the sections all floor/ceiling assemblies have insulation within them so all recessed cans will be required to be IC rated. Note this requirement on your RCPs. Also note the requirement that all recessed light fixtures placed in the thermal envelope will be IC rated and air sealed. FP Response: A general note has been added to all RCP Plans noting the requirement of all recessed light fixtures placed in the thermal envelope being IC rated and air sealed. REF: General Notes on A-701, A-702, and A-703. W-3 W-3 F-2FF-1F-3 PRESSURE TRESTED SILL PLATERE: STRUCTURAL FLASHING SLOPED 1/4" PER FOOT FOR DRAINAGE INTERNAL DECK DRAIN HANGERRE: STRUCTURAL PRESSURE TRESTED SILL PLATERE: STRUCTURAL BLOCKINGRE: STRUCTURALWIDE FLANGE BEAMRE: STRUCTURAL EXTERIOR INTERIOR INTERIOREXTERIOR (EX) RAFTERS - V.I.F INTERIOR 6SCALE: 1" = 1'-0"7 DECK & EXTERIOR WALL TRANSITION SCALE: 1" = 1'-0"10 ROOF AT RIDGE Not showing a continuous air barrier. Lower wall (W3) is incorrect as that is notan existing wall perthe floor plans. F-2 W-2 W-3 FF-1 HANGERRE: STRUCTURAL EXISTING JOISTRE: STRUCTURAL PRESSURE TREATED PLATERE: STRUCTURAL INTERIOR CRAWLSPACEW-2 FF-1 W-3 HANGERRE: STRUCTURAL TOP PLATERE: STRUCTURAL BEAMRE: STRUCTURAL BLOCKINGRE: STRUCTURAL SILL PLATERE: STRUCTURAL FLASHING DRAINAGE EXTERIOR INTERIOR INTERIOR F-3 F-2 SCALE: 1" = 1'-0"8 ROOF @ EXTERIOR WA LE: 1" = 1'-0" OOF @ EAVE In multiple details, sections, and on the floor plans you are making reference to W3 for an existing exterior wall where that is not the case. These two details are new exterior walls per where they are being referenced in the sections and need to be referenced correctly and consistently throughout your plans. The majority of south exterior wall is new. Make sure these incorrect references are corrected throughout your plan set. Provide a detail for the new exterior walls being proposed. All new exterior walls need to show a continuous air barrier to be tied into the existing construction, foundation, and roof construction and meet the residential insulation requirements. 101 104 201 201 202 B A A B A --- PWDR KITCHEN MASTER BEDROOM MASTER BEDROOM SITTING ROOM ENTRY GARAGE 2'-4"x7'-6"3'-0"x6'-8"2'-8"x8'-0"2'-8"x8'-0"2'-8"x6'-8" --- 2'-6"3'-2"2'-10"2'-10" 2'-6"7'-7"3'-2"6'-9"2'-8"8'-0"2'-10"8'-1"2'-10" PLAN 2'-10"2'-10"2'-10" View from Opening Side 2'-10"6'-9"2'-10"6'-9"2'-10" This door must meetthe requirements ofR302.5.1 as a opening between the garageand residence. Callout the compliantmaterial or fire ratingof the door and note the requirement for aself-closing device. 5 6 C W LIGHT FIXTU 1. ALL LIGHTING AND WITH CURRENT LOC2. SMOKE AND CARBLOCATIONS ARE SHOINSTALLER TO REFECOMPLIANCE OF HA GENERAL NO RECESS RECESS PENDAN WALL-MO LIGHT FIXTU ENERGY EFFICIE Per the sections all floor/ceiling assemblies have insulation within them so all recessed cans will be required to be IC rated. Note this requirement on your RCPs. Also note the requirement that all recessed light fixtures placed in the thermal envelope will be IC rated and air sealed. Subject: PlanCheck Page Label: 31 Author: justinh File Name: Architectural Permit Set.614 W North St.2017.10.pdf FP Response: A new assebmly W-4 has been added to the project on sheet A-501. This assembly has continuous insulation on the exterior. W-5 has also been updated to have continuous insulation on the exterior. All floor plans, sections, and details have been updated to show these revised assemblies. Detail 11 on Sheet A-502 demonstrates the connection between the existing stud wall and propsed wall with continous insulation. REF: A-102, A-103, A-301, A-302, A-303, A-501, A-502 Subject: PlanCheck Page Label: 33 Author: justinh File Name: Architectural Permit Set.614 W North St.2017.10.pdf FP Response: Door 104A will have a minimum 20-minute fire-rating to be used for circulation between the kitchen and garage. REF: A-603. 2/27/2018 Subject: PlanCheck Page Label: 34 Author: justinh File Name: Architectural Permit Set.614 W North St.2017.10.pdf FP Response: Exhaust fans have been added to all bathrooms and toilet rooms. Where applicable, exhaust fans are directly above toilets. REF: A-701, A-702, and A-703. Show bath exhaust fans in all required locations. If the toilet is located within a separate enclosure as it is in this instance you must provide a fan for both the toilet room and one in the main room for the shower. Subject: PlanCheck Page Label: 3 Author: justinh File Name: Special Inspection and Testing Agreement614 W North St.2017.10.pdf You are missing signatures on this form for the structural welding shown in the structural plans. Special Inspection and Testing Agreement614 W North St.2017.10.pdf (1) C C C C CC C CC CC CC CC W C C 99'-3 3/8"FLAT 99'-3 3/8"FLAT 99'-3 3/8"FLAT MEDIA005 BEDROOM 4006 BATH 3007 BEDROOM 3008 Show bath exhaust fans in all required locations. If the toilet is located within a separate enclosure as it is in this instance you must provide a fan for both the toilet room and one in the main room for the shower. 3 G.Building Department Responsibilities 1.Approve special-inspection program. The building department shall approve allspecial inspectors and special-inspection requirements. 2.Enforce special inspection. Work requiring special inspection and the buildinginspector shall monitor the performance of special inspectors. His\Her approval, inaddition to that of the special inspector, must be obtained prior to placement of concrete,covering of structural steel, or other similar materials. 3.Review inspection reports. The building official should review special-inspectionprogress and final reports. 4.Perform final inspection. The building official should perform the final inspection andapproval for a project [IBC Sec. 109.3.1] after the final special-inspection report has beenreviewed and approved. Project Address: __________________________________ Permit Number:______________________ ACKNOWLEDGMENTS I have read and agree to comply with the conditions of this agreement. Special Inspection Agency: __________________________ Owner: __________________________ Engineer/ Architect: __________________________ Contractor: __________________________ Approved Fabricator: __________________________ Inspected Fabricator: __________________________ (circle one) CITY OF ASPEN PITKIN COUNTY: Signature: __________________________ Signature: __________________________ Signature: __________________________ Signature: __________________________ Signature: __________________________ Signature: __________________________ Signature: __________________________ Printed Name: __________________________ Printed Name __________________________ Printed Name: __________________________ Printed Name: __________________________ Printed Name: __________________________ Printed Name: __________________________ Printed Name: __________________________ Date: __________________________ Date __________________________ Date: __________________________ Date: __________________________ Date: __________________________ Date: __________________________ Date: __________________________ Nicholas Hayman 10/2/17 Andrew Mishmash 10/2/2017AM2 Inc Forum Phi Steev Wilson 10/3/17 10/11/17 You are missing signatures on this form for the structural welding shown in the structural plans. FP Response: A signature for structural welding will be provided at the time of permit issuance. 2/27/2018