HomeMy WebLinkAboutFile Documents.210 S 1st St.0281.2017 (5).ARBK ...... Subject: PlanCheck Page Label: SNOWMELT PLAN These square footages should 1 MI— Author:justinh match. If the 135 SF is the ° correct amount be sure to revise - = File Name:A-Architectural Plans.210 1st..2017.10.pdf ° that on the above table on this Current mechanical design can accommodate either sheet as well as on the REMP aa avE" .-O. 135 or 133 square feet form as the 133 SF was used for sNo both. PLAr Subject: PlanCheck _1 Page Label: SNOWMELT PLAN Are you proposing to snowmelt e°°°'"°°e�'� ,° Author:justinh the stairs or just the deck area e°m al ae:, re� e QB"� L File Name: A-Architectural Plans.210 1st..2017.10.pdf under them? The floor plans call w�m • out metal stairs but there is a detail in the mechanical plans for F '. concrete steps with snowmelt tubing. Please clarify and revise if needed for consistancy. Subject: PlanCheck I Page Label: UPPER PLAN Maximum riser height is 7 3/4" ' Author:justinh per R311.7.5.1, please revise on p11r ".� File Name: A-Architectural Plans.210 1st..2017.10.pdf this sheet as well as on the roof PI—RIM. III plan. Provide a stair detail :'ram 1' ' showing compliant riser height, - tread depth, handrail and guard © -7 height, handrail size/type. Open risers where 30"above grade or __ _ _. greater are required to limit the opening to 4"or less. M-Mechanical Plan Set.210 1st.2017.10.pdf(4) Subject: PlanCheck The O.A. intake is not allowed in i ! j Page Label: M1 2 these locations as the covered i ! Author:justinh in i •File Name: M-Mechanical Plan Set.210 1st.2017.10.pdf drive way is considered a - , a,if R303.5.1 prohibits 1 , ,q,,.,® intake openings within 10'of I O.A. Intake has been re-located to be 10 away from drive lane. Intake is now located near G.L. 4 & B streets or parking areas. Subject: PlanCheck You are showing a range hood Page Label: M1-3 Author:justinh on this plan but no information is °° a P P� File Name: M-Mechanical Plan Set.210 1st.2017.10.pdf provided regarding it on the equipment schedules. Please ® ii,j1 _,,,I;;;,[ � Exhaust hood to be recirculating type with filter. See revise the equipment schedules Architect for additional info. to show the actual kitchen ' -, exhaust system you are proposing. RECEIVED 10/09/18 ASPEN BUILDING DEPARTMENT Subject: PlanCheck Page Label: M1-5 Please provide more information Please provide more information Author:justinh showing how the balanced — showing how the balanced whole File Name: M-Mechanical Plan Set.210 1 st.2017.10.pdf whole house ventilation required houseventilationrequiredbyCOA �,� ' byCOAunici al code — municipal code 8.44.020(m)is being p . Fan Coils will provide the ventilation air by pulling in O.A.through provided. I need more information K louvers.The current mechanical design shows about 10%outside air 8.44.020(m) is being provided. I on the exhaust rate of the whole ' provided to the fan coil units(with the exception of the two fan coils need more information on the house ventilation system so that I ,; ,, serving the kitchen.These units will operate and provide,make up air i can verify that supply and return are z ,,Ex when the kitchen exhaust hood is running in order to maintain exhaust rate of the whole house balanced within 20%of each other. building pressures.When°the kitchen hood is not running,these two ventilation system so that I can units shall reduce to a 10%outside airflow.contractor to verify exhaust hood requirement and adjust outside airflow set points verify that supply and return are accordingly).The outside airflows listed on the plans not only meet, balanced within 20%of each but exceed the required ventilation airflow.Through the unit's controls,the fan coils shall be set to operate 1 hour in every 4 hours. other. Air balance calculation can be provided if required. Subject: PlanCheck Page Label: M1 6 Where are snowmelted steps Author:justinh being proposed? Per the File Name: M-Mechanical Plan Set.210 1st.2017.10.pdf architectural plans the stairs on the snowmelted deck are metal. ,,1 - Stair detail removed per architect direction. a Pam —'i mr E RECEIVED 10/09/18 ASPEN BUILDING DEPARTMENT i SubjectHPC } Page: Sheet A-101 Main Plan:Electric, --- - -- - - - --- -- -- MAIN PLAN --' Author;sarahy Gas,Water meters are in a Architect to confirm final location of utilities with contractor and utility location that differs from the ` __ � provider. Mechanical plans. Please adjust. • � I � The location needs to be ih11 approved by staff and monitor 6:=:1Ve ,T according to the HPC Resolution ono,�1+-�� Ir #38,Series of 2007. IILIP p M-Mechanical Plan Set.210 1st.2017.10.pdf(4) ! ! ! ! Subject: PlanCheck f i I I Page Label:M1-2 (� The O.A.intake is not allowed in ! i i ! Author:justinh these locations as the covered I ! File Name: M-Mechanical Plat t .2017.10.pdf drive way is considered a --- met carport. R303.5-1 prohibits t �/ intake openings within 10'of ; streets or parking areas. Subject- 1V I l Page P You are showing a range hood ,,,�, A ,. on this plan but no information is �""" provided regarding it on the I F" ` _ -Mechanical Plan Set.210 1st.2017.10.pdf ``�)V equipment schedules. Please V revise the equipment schedules " - ° I to show the actual kitchen VI IT � i O exhaust system you are ( I proposing. RECEIVED 10/09/18 ASPEN BUILDING DEPARTMENT