Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
File Documents.210 S 1st St.0281.2017 (8).ARBK
South 210 Residence - 17146 Location Aspen, Colorado Building owner Program user Robert Lueck Company Bighorn Consulting Engineers Comments Walls entered per project north and builiding orientation adjusted to true north By Bighorn Consulting Engineers Dataset name Z:\2017 Projects\17146 210 S First Aspen\loads and calculations\MECHANICAL\S 210 Residence- 17146.trc Calculation time 05:32 PM on 10/12/2017 TRACE®700 version 6.3.3 Location Aspen, CO Latitude 39.2 deg Longitude 106.8 deg Time Zone 7 Elevation 7,908 ft Barometric pressure 24.0 in. Hg Air density 0.0608 lb/cu ft Air specific heat 0.2444 Btu/Ib•°F Density-specific heat product 0.8912 Btu/h•cfm•°F Latent heat factor 3,923.0 Btu•min/h•cu ft Enthalpy factor 3.6459 Ib•min/hr•cu ft Summer design dry bulb 81.0 °F Summer design wet bulb 61.0 °F Winter design dry bulb -15.0 °F Summer clearness number 1.02 Winter clearness number 1.02 Summer ground reflectance 0.20 Winter ground reflectance 0.20 Carbon Dioxide Level 400 ppm Design simulation period January-December Cooling load methodology TETD-TA1 Heating load methodology UATD EIVED -700 TRANE. omprehensive b Idi naly / =earefrom,4 b�$b 9 18 ASPEN BUILDING DEPARTMENT System Checksums By Bighorn Consulting Engineers FC-1 Fan Coil COOLING COIL PEAK CLG SPACE PEAK HEATING COIL PEAK TEMPERATURES Peaked at Time: Mo/Hr: 7/17 Mo/Hr:Sum of Mo/Hr: Heating Design Cooling Heating Outside Air: OADB/WB/HR: 76/59/66 OADB:Peaks OADB: -15 SADB 55.0 121.4 Ra Plenum 72.4 71.9 Space Plenum Net Percent Space Percent Space Peak Coil Peak Percent Return 72.4 71.9 Sens.+Lat. Sens.+Lat Total Of Total Sensible Of Total Space Sens Tot Sens Of Total Ret/OA 72.9 59.2 Btu/h Btu/h Btu/h (%) Btu/h (%) Btu/h Btu/h (%) Fn MtrTD 0.1 0.0 Envelope Loads Envelope Loads Fn BIdTD 0.1 0.0 Skylite Solar 0 0 0 0 0 0 Skylite Solar 0 0 0.00 Fn Frict 0.3 0.0 Skylite Cond 0 0 0 0 0 0 Skylite Cond 0 0 0.00 Roof Cond 0 0 0 0 0 0 Roof Cond 0 0 0.00 Glass Solar 5,421 0 5,421 31 5,601 36 Glass Solar 0 0 0.00 AIRFLOWS Glass/Door Cond 81 0 81 0 57 0 Glass/Door Cond -1,646 -1,646 2.90 Cooling Heating Wall Cond 123 55 179 1 145 1 Wall Cond -225 -326 0.57 Partition/Door -7,340 -7,340 -42 -7,340 -47 Partition/Door -30,182 -30,182 53.11 Diffuser 1,026 1,026 Floor 0 0 0 0 0 Floor -7,319 -7,319 12.88 Terminal 1,026 1,026 Adjacent Floor 0 0 0 0 0 0 Adjacent Floor 0 0 0 Main Fan 1,026 1,026 Infiltration 210 210 1 234 2 Infiltration -5,738 -5,738 10.10 Sec Fan 0 0 Sub Total==> -1,505 55 -1,450 -8 -1,304 -8 Sub Total==> -45,110 -45,211 79.56 Nom Vent 150 150 AHU Vent 150 150 Internal Loads Internal Loads Infil 74 74 Lights 2,021 505 2,526 14 2,021 13 Lights 0 0 0.00 MinStop/Rh 0 0 People 3,500 0 3,500 20 2,450 16 People 0 0 0.00 Return 1,100 1,100 Misc 0 0 0 0 0 0 Misc 0 0 0.00 Exhaust 224 224 Sub Total=_> 5,521 505 6,026 34 4,471 29 Sub Total==> 0 0 0.00 Rm Exh 0 0 Auxiliary 0 0 Ceiling Load 181 -181 0 0 179 1 Ceiling Load -33 0 0.00 Leakage Dwn 0 0 Ventilation Load 0 0 385 2 0 0 Ventilation Load 0 -11,630 20.47 Leakage Ups 0 0 Adj Air Trans Heat 0 0 0 0 0 Adj Air Trans Heat 0 0 0 Dehumid.Ov Sizing 0 0 OvlUndr Sizing 0 0 0.00 Ov/Undr Sizing 12,194 12,194 70 12,194 78 Exhaust Heat 14 -0.02 ENGINEERING CKS Exhaust Heat -77 -77 0 OA Preheat Diff. 0 0.00 Sup.Fan Heat 456 3 RA Preheat Diff. 0 0.00 Cooling Heating Ret.Fan Heat 0 0 0 Additional Reheat 0 0.00 %OA 14.6 14.6 Duct Heat Pkup 0 0 0 cfm/ft' 0.69 0.69 Underflr Sup Ht Pkup 0 0 Underflr Sup Ht Pkup 0 0.00 cfm/ton 702.01 Supply Air Leakage 0 0 0 Supply Air Leakage 0 0.00 ft'/ton 1,012.92 Btulhrft' 11.85 -38.40 Grand Total=_> 16,391 302 17,534 100.00 15,540 100.00 Grand Total=_> -45,142 -56,827 100.00 No.People 10 COOLING COIL SELECTION AREAS HEATING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR Leave DB/WB/HR Gross Total Glass Capacity Coil Airflow Ent Lvg ton MBh MBh cfm °F °F gr/lb °F °F gr/Ib fe (%) MBh cfm °F °F Main Clg 1.5 17.5 16.6 1,026 73.4 58.2 66.5 55.0 51.5 65.2 Floor 1,480 Main Htg -56.8 1,026 59.2 121.4 Aux Clg 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Part 1,746 Aux Htg 0.0 0 0.0 0.0 Opt Vent 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Int Door 0 Preheat 0.0 0 0.0 0.0 ExFlr 168 Total 1.5 17.5 Roof 0 0 0 Humidif 0.0 0 0.0 0.0 Wall 147 68 46 Opt Vent 0.0 Ext Door 0 0 0 Total -56.8 RECEIVED Project Name: South 210 Residence-17146 TRACE®700 v6.3.3 calculated at 05:32 PM-WI/Pig/7 18 Dataset Name: S 210 Residence-17146.trc Alternative-1 System Checksums Report Page 1 of 4 ASPEN BUILDING DEPARTMENT System Checksums By Bighorn Consulting Engineers FC-2 Fan Coil COOLING COIL PEAK CLG SPACE PEAK HEATING COIL PEAK TEMPERATURES Peaked at Time: Mo/Hr: 7/17 Mo/Hr:Sum of Mo/Hr: Heating Design Cooling Heating Outside Air: OADB/WB/HR: 76/59/66 OADB:Peaks OADB: -15 SADB 55.0 86.0 Ra Plenum 72.5 71.3 Space Plenum Net Percent Space Percent Space Peak Coil Peak Percent Return 72.5 71.3 Sens.+Lat. Sens.+Lat Total Of Total Sensible Of Total Space Sens Tot Sens Of Total Ret/OA 72.6 68.4 Btu/h Btu/h Btu/h (%) Btu/h (%) Btu/h Btu/h (%) Fn MtrTD 0.1 0.0 Envelope Loads Envelope Loads Fn BIdTD 0.1 0.0 Skylite Solar 0 0 0 0 0 0 Skylite Solar 0 0 0.00 Fn Frict 0.3 0.0 Skylite Cond 0 0 0 0 0 0 Skylite Cond 0 0 0.00 Roof Cond 0 0 0 0 0 0 Roof Cond 0 0 0.00 Glass Solar 7,911 0 7,911 66 11,651 86 Glass Solar 0 0 0.00 AIRFLOWS Glass/Door Cond 281 0 281 2 -366 -3 Glass/Door Cond -5,580 -5,580 39.69 Cooling Heating Wall Cond 1,076 288 1,364 11 1,037 8 Wall Cond -2,867 -3,637 25.87 Partition/Door 0 0 0 0 0 Partition/Door 0 0 0.00 Diffuser 896 896 Floor 0 0 0 0 0 Floor 0 0 0.00 Terminal 896 896 Adjacent Floor 0 0 0 0 0 0 Adjacent Floor 0 0 0 Main Fan 896 896 Infiltration 187 187 2 -224 -2 Infiltration -2,559 -2,559 18.20 Sec Fan 0 0 Sub Total==> 9,455 288 9,743 81 12,098 89 Sub Total==> -11,005 -11,775 83.75 Nom Vent 30 30 AHU Vent 30 30 Internal Loads Internal Loads Infil 33 33 Lights 901 225 1,126 9 901 7 Lights 0 0 0.00 MinStop/Rh 0 0 People 700 0 700 6 490 4 People 0 0 0.00 Return 929 929 Misc 0 0 0 0 0 0 Misc 0 0 0.00 Exhaust 63 63 Sub Total==> 1,601 225 1,826 15 1,391 10 Sub Total==> 0 0 0.00 Rm Exh 0 0 Auxiliary 0 0 Ceiling Load 104 -104 0 0 85 1 Ceiling Load -155 0 0.00 Leakage Dwn 0 0 Ventilation Load 0 0 122 1 0 0 Ventilation Load 0 -2,326 16.54 Leakage Ups 0 0 Adj Air Trans Heat 0 0 0 0 0 Adj Air Trans Heat 0 0 0 Dehumid.Ov Sizing 0 0 Ov/Undr Sizing 0 0 0.00 Ov/Undr Sizing 0 0 0 0 0 Exhaust Heat 42 -0.30 ENGINEERING CKS Exhaust Heat -28 -28 0 OA Preheat Diff. 0 0.00 Sup.Fan Heat 398 3 RA Preheat Diff. 0 0.00 Cooling Heating Ret.Fan Heat 0 0 0 Additional Reheat 0 0.00 %OA 3.3 3.3 Duct Heat Pkup 0 0 0 cfm/ft' 1.36 1.36 Underflr Sup Ht Pkup 0 0 Underflr Sup Ht Pkup 0 0.00 cfm/ton 891.34 Supply Air Leakage 0 0 0 Supply Air Leakage 0 0.00 ft'/ton 656.62 Btulhrft' 18.28 -21.30 Grand Total=_> 11,160 381 12,062 100.00 13,574 100.00 Grand Total=_> -11,160 -14,060 100.00 No.People 2 COOLING COIL SELECTION AREAS HEATING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR Leave DBIWB/HR Gross Total Glass Capacity Coil Airflow Ent Lvg ton MBh MBh cfm °F °F gr/lb °F °F gr/Ib fe (%) MBh cfm °F °F Main Clg 1.0 12.1 11.8 896 73.1 57.2 61.7 55.0 50.7 61.7 Floor 660 Main Htg -14.1 896 68.4 86.0 Aux Clg 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Part 0 Aux Htg 0.0 0 0.0 0.0 Opt Vent 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Int Door 0 Preheat 0.0 0 0.0 0.0 ExFlr 0 Total 1.0 12.1 Roof 0 0 0 Humidif 0.0 0 0.0 0.0 Wall 1,075 196 18 Opt Vent 0.0 Ext Door 50 0 0 Total -14.1 RECEIVED 111E Project Name: South 210 Residence-17146 TRACE®700 v6.3.3 calculated at 05:32 PM-WI/Pig/7 18 Dataset Name: S 210 Residence-17146.trc Alternative-1 System Checksums Report Page 2 of 4 ASPEN BUILDING DEPARTMENT System Checksums By Bighorn Consulting Engineers FC-3 Fan Coil COOLING COIL PEAK CLG SPACE PEAK HEATING COIL PEAK TEMPERATURES Peaked at Time: Mo/Hr: 7/17 Mo/Hr:Sum of Mo/Hr: Heating Design Cooling Heating Outside Air: OADB/WB/HR: 76/59/66 OADB:Peaks OADB: -15 SADB 55.0 80.9 Ra Plenum 72.4 69.8 Space Plenum Net Percent Space Percent Space Peak Coil Peak Percent Return 72.4 69.8 Sens.+Lat. Sens.+Lat Total Of Total Sensible Of Total Space Sens Tot Sens Of Total Ret/OA 72.5 66.7 Btu/h Btu/h Btu/h (%) Btu/h (%) Btu/h Btu/h (%) Fn MtrTD 0.1 0.0 Envelope Loads Envelope Loads Fn BIdTD 0.1 0.0 Skylite Solar 7,494 0 7,494 18 7,494 20 Skylite Solar 0 0 0.00 Fn Frict 0.3 0.0 Skylite Cond 0 146 146 0 0 0 Skylite Cond 0 -3,201 10.11 Roof Cond 0 229 229 1 0 0 Roof Cond 0 -1,540 4.86 Glass Solar 25,671 0 25,671 63 25,671 68 Glass Solar 0 0 0.00 AIRFLOWS Glass/Door Cond 619 0 619 2 619 2 Glass/Door Cond -12,309 -12,309 38.88 Cooling Heating Wall Cond 1,010 332 1,343 3 1,010 3 Wall Cond -3,161 -4,189 13.23 Partition/Door 0 0 0 0 0 Partition/Door 0 0 0.00 Diffuser 2,499 2,499 Floor 0 0 0 0 0 Floor 0 0 0.00 Terminal 2,499 2,499 Adjacent Floor 0 0 0 0 0 0 Adjacent Floor 0 0 0 Main Fan 2,499 2,499 Infiltration 255 255 1 158 0 Infiltration -3,722 -3,722 11.75 Sec Fan 0 0 Sub Total==> 35,049 707 35,756 87 34,952 92 Sub Total==> -19,192 -24,960 78.83 Nom Vent 90 90 AHU Vent 90 90 Internal Loads Internal Loads Infil 48 48 Lights 1,311 328 1,638 4 1,311 3 Lights 0 0 0.00 MinStop/Rh 0 0 People 2,100 0 2,100 5 1,470 4 People 0 0 0.00 Return 2,547 2,547 Misc 0 0 0 0 0 0 Misc 0 0 0.00 Exhaust 138 138 Sub Total==> 3,411 328 3,738 9 2,781 7 Sub Total==> 0 0 0.00 Rm Exh 0 0 Auxiliary 0 0 Ceiling Load 122 -122 0 0 122 0 Ceiling Load -682 0 0.00 Leakage Dwn 0 0 Ventilation Load 0 0 477 1 0 0 Ventilation Load 0 -6,978 22.04 Leakage Ups 0 0 Adj Air Trans Heat 0 0 0 0 0 Adj Air Trans Heat 0 0 0 Dehumid.Ov Sizing 0 0 OvlUndr Sizing 0 0 0.00 Ov/Undr Sizing 0 0 0 0 0 Exhaust Heat 276 -0.87 ENGINEERING CKS Exhaust Heat -49 -49 0 OA Preheat Diff. 0 0.00 Sup.Fan Heat 1,111 3 RA Preheat Diff. 0 0.00 Cooling Heating Ret.Fan Heat 0 0 0 Additional Reheat 0 0.00 %OA 3.6 3.6 Duct Heat Pkup 0 0 0 cfm/ft' 2.60 2.60 Underflr Sup Ht Pkup 0 0 Underflr Sup Ht Pkup 0 0.00 cfm/ton 730.71 Supply Air Leakage 0 0 0 Supply Air Leakage 0 0.00 ft'/ton 280.75 Btulhrft' 42.74 -32.98 Grand Total==> 38,582 863 41,033 100.00 37,855 100.00 Grand Total=_> -19,874 -31,663 100.00 No.People 6 COOLING COIL SELECTION AREAS HEATING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR Leave DB/WB/HR Gross Total Glass Capacity Coil Airflow Ent Lvg ton MBh MBh cfm °F °F gr/lb °F °F gr/Ib fe (%) MBh cfm °F °F Main Clg 3.4 41.0 40.1 2,499 73.0 57.3 62.3 55.0 50.6 61.6 Floor 960 Main Htg -31.7 2,499 66.7 80.9 Aux Clg 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Part 0 Aux Htg 0.0 0 0.0 0.0 Opt Vent 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Int Door 0 Preheat 0.0 0 0.0 0.0 ExFlr 0 Total 3.4 41.0 Roof 960 70 7 Humidif 0.0 0 0.0 0.0 Wall 1,528 510 33 Opt Vent 0.0 Ext Door 0 0 0 Total -31.7 RECEIVED IVE Project Name: South 210 Residence-17146 TRACE®700 v6.3.3 calculated at 05:32 PM-WI/Pig/7 18 Dataset Name: S 210 Residence-17146.trc Alternative-1 System Checksums Report Page 3 of 4 ASPEN BUILDING DEPARTMENT System Checksums By Bighorn Consulting Engineers RAD-1 Radiation(Heating Only) COOLING COIL PEAK CLG SPACE PEAK HEATING COIL PEAK TEMPERATURES Peaked at Time: Mo/Hr: 0/0 Mo/Hr:0/0 Mo/Hr: Heating Design Cooling Heating Outside Air: OADB/WB/HR: 0/0/0 OADB:0 OADB: -15 SADB 0.0 72.0 Ra Plenum 0.0 67.3 Space Plenum Net Percent Space Percent Space Peak Coil Peak Percent Return 0.0 67.3 Sens.+Lat. Sens.+Lat Total Of Total Sensible Of Total Space Sens Tot Sens Of Total Ret/OA 0.0 67.3 Btu/h Btu/h Btu/h (%) Btu/h (%) Btu/h Btu/h (%) Fn MtrTD 0.0 0.0 Envelope Loads Envelope Loads Fn BIdTD 0.0 0.0 Skylite Solar 0 0 0 0 0 0 Skylite Solar 0 0 0.00 Fn Frict 0.0 0.0 Skylite Cond 0 0 0 0 0 0 Skylite Cond 0 0 0.00 Roof Cond 0 0 0 0 0 0 Roof Cond 0 -102 1.96 Glass Solar 0 0 0 0 0 0 Glass Solar 0 0 0.00 AIRFLOWS Glass/Door Cond 0 0 0 0 0 0 Glass/Door Cond -2,302 -2,302 44.23 Cooling Heating Wall Cond 0 0 0 0 0 0 Wall Cond -1,422 -1,788 34.35 Partition/Door 0 0 0 0 0 Partition/Door 0 0 0.00 Diffuser 0 0 Floor 0 0 0 0 0 Floor 0 0 0.00 Terminal 0 0 Adjacent Floor 0 0 0 0 0 0 Adjacent Floor 0 0 0 Main Fan 0 0 Infiltration 0 0 0 0 0 Infiltration -1,071 -1,071 20.57 Sec Fan 0 0 Sub Total==> 0 0 0 0 0 0 Sub Total==> -4,795 -5,263 101.11 Nom Vent 0 0 AHU Vent 0 0 Internal Loads Internal Loads Infil 0 14 Lights 0 0 0 0 0 0 Lights 0 0 0.00 MinStop/Rh 0 0 People 0 0 0 0 0 0 People 0 0 0.00 Return 0 14 Misc 0 0 0 0 0 0 Misc 0 0 0.00 Exhaust 0 14 Sub Total==> 0 0 0 0 0 0 Sub Total==> 0 0 0.00 Rm Exh 0 0 Auxiliary 0 0 Ceiling Load 0 0 0 0 0 0 Ceiling Load -410 0 0.00 Leakage Dwn 0 0 Ventilation Load 0 0 0 0 0 0 Ventilation Load 0 0 0.00 Leakage Ups 0 0 Adj Air Trans Heat 0 0 0 0 0 Adj Air Trans Heat 0 0 0 Dehumid.Ov Sizing 0 0 OvlUndr Sizing 0 0 0.00 Ov/Undr Sizing 0 0 0 0 0 Exhaust Heat 58 -1.11 ENGINEERING CKS Exhaust Heat 0 0 0 OA Preheat Diff. 0 0.00 Sup.Fan Heat 0 0 RA Preheat Diff. 0 0.00 Cooling Heating Ret.Fan Heat 0 0 0 Additional Reheat 0 0.00 %OA 0.0 0.0 Duct Heat Pkup 0 0 0 cfm/ft' 0.00 0.00 Underflr Sup Ht Pkup 0 0 Underflr Sup Ht Pkup 0 0.00 cfm/ton 0.00 Supply Air Leakage 0 0 0 Supply Air Leakage 0 0.00 ft'/ton 0.00 Btulhr•ft' 0.00 -18.84 Grand Total==> 0 0 0 100.00 0 100.00 Grand Total=_> -5,205 -5,205 100.00 No.People 0 COOLING COIL SELECTION AREAS HEATING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR Leave DB/WB/HR Gross Total Glass Capacity Coil Airflow Ent Lvg ton MBh MBh cfm °F °F gr/lb °F °F gr/Ib ft' (%) MBh cfm °F °F Main Clg 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Floor 276 Main Htg -5.2 0 0.0 0.0 Aux Clg 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Part 0 Aux Htg 0.0 0 0.0 0.0 Opt Vent 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Int Door 0 Preheat 0.0 0 0.0 0.0 ExFlr 0 Total 0.0 0.0 Roof 61 0 0 Humidif 0.0 0 0.0 0.0 Wall 462 25 5 Opt Vent 0.0 Ext Door 98 0 0 Total -5.2 RECEIVED Project Name: South 210 Residence-17146 TRACE®700 v6.3.3 calculated at 05:32 PM-WI/Pig/7 18 Dataset Name: S 210 Residence-17146.trc Alternative-1 System Checksums Report Page 4 of 4 ASPEN BUILDING DEPARTMENT