HomeMy WebLinkAboutFile Documents.743 Cemetery Ln.0011.2018 (18).ARBK I N. In accordance wan AAMA-13U4 and AS I M F642 requirements ,. FEATURES PERFORMANCE OPTIONS (/PRODUCTS/SL70) (/PRODUCTS/SL70/PERF (/PRODUCTS/SL70/C ORMANCE) - NS) El))) The SL70 with insulated tempered glass with STC 32 achieved STC and Rw values of 32 The SL70 with STC 47laminated glass achieved STC and Rw values of 45 and OITC of 35. Acoustical Performance° 0 Excerpts of results of 3 separate units of various panels and configurations tested by Architectural Testing,Inc.,Fresno,CA, an independent testing laboratory in October 2009 per various fenestration test standards. 0 For Canada,tested to NAFS-08 or equivalent and CSA A44051-09. (f Excerpts of results of T3'7'W x 8'8'H five panel units with raised sill tested by Nusing Mobile Trennwandtechr>ile,Munster.Germany, an independent testing laboratory,in October 2003 and November 2005. 0 Excerpts of results of a 13'1'W x 10'H(4000 mm x 3050 mm)four panel unit tested by Architectural Testing,Inc.,Fresno,CA,an independent testing laboratory,in October 2015 per AAMA/WDMA/CSA 101/1.S.2/A440,NAFS-North American Fenstration Standard ICI Rated,certified and labeled in accordance with NFRC 100+200 Thermal Performance f INWARDOP= •- Ri-,j'0'_x_ TYPE OF CENTER IG GLASS UNIT 2015UNIT 2015 GLASS(1 LITE)C OF GLASS THICKNESS U-FACTOR SHGC© VT° ENERGY U FACTOR SHGC© VTR ENERGY U-FACTOR STAR STAR DoublelGClear 15/16'.48 50 51 54 SO 51 .54 (air filled) (24 mm) Double IC Low E 15/16' 26 34 19 .42 - .34 19 42 - (argon filled) (24 mm) Double IG Low E 15/16" 37 19 42 37 19 42 (air filled) .30 (24 mm) Double IG Low E 15/16' #2&#4 surfaces .21 (24 mm) .31 .18 39 - .31 18 .39 - (argon filled) Double IG Low E#2& 15/16' 24 33 .18 .39 33 19 39 #4 surfaces(air filled) (24 mm) Triple IG Low E x 2 13 11/7 .26 .24 .39 * .26 .24 .39 * (argon filled) (38 mm) I I 1331 * I Triple IG Low E x 2 13 11/2 ,2g 24 39 (air filled) (38 mm) Triple IG Low E x 2 (hard coat, .15 (381mm) .28 .41 .43 - .28 .41 .43 - argon filled) Triple IG Low E x 2 17 11/2 .30 .41 .43 - .30 .41 .43 - (hard coat.air filled) (38 mm) NOTES O NFRC simulated U factors of units with a horizontal mullion will have values of.01 to.02 higher ©SHGC=Solar Heat Gain Coefficient than units with no horizontal mullion.Please contact NanaWall for details. O VT=Visible Transmittance *2015 Energy Star Qualification Criteria:U-Factor for doors in all climate zones c30,SHGC<25 in South/South Central zones and<.40 in North/North Central zones.(For guidance only.NanaWall is not a participant of the Energy Star program.) R E(E Ir FE D Call NanaWall for U-Factor&SHGC for other glass types 01/11/2018 ASPEN BUILDING DEPARTMENT