HomeMy WebLinkAboutFile Documents.210 S 1st St.0281.2017 (15).ARBK HIGH EFFICIENCY CONDENSING BOILERS Oiii_mi AK cillill IGH' WALL MOUNT BOILER TM CON XUS' REMOTE CONNECT CAPABLE r SMARTY Mr- OPERATING CONTROL FEATURING A BUILT-IN CASCADING SEQUENCER 7 MODELS: 55,000 — 399,999 BTU/HR ® • 5:1 TURNDOWN RATIO ,iir—____LESS THAN 20 ppm NOx DIRECT VENT FLEXIBILITY TO 100 FEET 95% AFUE h ��_�` EFFICIENCY host Efficient LOW NOx - 2015 ..°ertMed ENERGY STAR vww.energyslar.gov fc }v ?�.,, TL4©©llfllllr® HIGH EFFICIENCY BOILERS &WATER HEATERS Lochinvar 01 0 TM THE SMARTEST CHOICE FOR NIGH CONDENSING BOILER PERFORMANCE WALL MOUNT BOILER The KNIGHT Wall Mount, engineered with Lochinvar's exclusive SMART SYSTEMTM control and an array of other innovative features is far ahead of any heating boiler in its class.It promises and delivers ultimate ease of installation and maintenance.With up to 99% efficiency, low-NOx emissions and a fully modulating burner, it is the best"green choice"for today's environmentally focused market. Seven modulating/condensing stainless steel KNIGHT Wall Mount boilers are available with 55,000-399,999 Btu/hr inputs in a space- saving wall-mounted design.All are equipped for direct-vent installation with air intake and exhaust runs up to 100 feet using PVC,CPVC, Polypropylene or AL29-4C vent materials. This range of choices is ideal for residential or light-duty applications such as small hotels, schools and office buildings. For higher-demand applications, up to eight KNIGHT Wall Mount units can be installed utilizing the built-in cascading sequencer to deliver up to 3.2 million Btu/hr heating capacity. The KNIGHT Wall Mount Boiler reflects Lochinvar's constant commitment to providing all the options you need to serve every application. ADVANCED NEGATIVE REGULATION TECHNOLOGY it 1 KNIGHT safely and reliably operates with supply gas pressure as low as 4 inches water column. Negative Regulation (Neg/Reg)technology automatically adjusts fan speed to ensure the correct volume and mix of fuel and air throughout the firing range. UB D ThisFIRE fully weldedTE ASME CertifESIGNied stainless steel heat exchanger uses oval shaped tubes to pass heat from the products of combustion into the water stored in the vessel.To facilitate heat transfer the tubes are manufactured with dimples 4ii , , to slow the flue products and extract available latent energy.With a fire tube design the flue products are inside o#4' tapered passage ways and the water is passed through the vessel. Since the flue products pass through tubes 1.--1 .• a and the water is circulated through a larger diameter vessel a fire tube design allows for minimal head pressure loss through the boiler which allows the boiler to be installed easily into various hydronic applications. WATER-BACKED COMBUSTION CHAMBER - An outstanding feature of the fire tube design is a water backed combustion chamber. By having the combustion Ichamber surrounded by water the Knight Wall Mount has more heating surface area.This larger heating surface I area allows for efficiencies up to 99%. FULLY MODULATING BURNER I The SMART SYSTEM allows fully modulating combustion with 5:1 turndown.The burner can fire as low as 20% 1,. of maximum input and modulates the firing rate up to 100%as demand increases.The burner is a single •.it�• stainless steel assembly covered with woven steel mesh and fires in a 360° pattern along the entire length �� - Q%6• of the burner.This allows the compact KNIGHT to exceed the modulation capacities of units with larger 1 • 'r multiple burners. DIRECT VENTING UP TO 100 FEET KNIGHT offers 5 venting options and tremendous flexibility for placement of units within the building, because it permits direct-vent air intake and exhaust runs up to 100 equivalent feet using either PVC,CPVC,Polypropylene or AL29-4C stainless steel vent pipe. 5 FLEXIBLE VENTING OPTIONS Direct Vent Sidewall Direct Vent Vertical Vertical w/Sidewall Air Concentric Direct Vent Vertical* Concentric Direct Vent Sidewall* io " J \_ ,L. *Optional Vent Kit Sold Separately ��, R�� ,S MART 42i4 az _DH TTA 1 3 +; SCRou REFINED DESIGN PUTS MORE CONTR MEM��RK 1S6pF�138� ' AND INFORMATION AT YOUR FINGERTI foci,-.,RE:N sHpN • Advanced features include: _ • MULTI-COLOR GRAPHIC LCD DISPLAY • NAVIGATION DIAL kMct • USB PORT ' • ABILITY TO CONTROL UP TO THREE DIFFERENT SETPOINT TEMPERATURES • COMPATIBILITY WITH COPPER-FIN II NON-CONDENSING BOILER AT-A-GLANCE CREATE A FRONT-END LOADING SYSTEM AT-A-GLANCE COLOR CODING • BOILERS WITH DIFFERENT INPUTS CAN BE CASCADED TOGETHER TO MAXIMIZE BOILER PLANT TURNDOWN I — e7.�1 -mo• MODBUS CAPABILITY(OPTIONAL) I . . • DHW MODULATION LIMITING • DHW NIGHT SETBACK* • 0-10 V BOILER RATE OUTPUT BLUE SCREEN YELLOW SCREEN RED SCREEN • 0-10 V SIGNAL TO CONTROLVARIABLE SPEED BOILER PUMP* Normal system Maintenance due-shows Lockout mode. • 0-10 V SYSTEM PUMP SIGNAL INPUT* operation. the installer's name and • HEAT DEMAND FROM 0-10V INPUT number on the display. • INSTALLER CAN PROGRAM NAME AND NUMBER INTO THE BOILER • INSTALLER ADJUSTABLE FREEZE PROTECTION PARAMETERS • SEPARATELY ADJUSTABLE SH/DHW SWITCHING TIMES* • INSTALLER ACCESS TO BMS AND RAMP DELAY SETTINGS 01.11 *EXCLUSIVE To LOCHINV.QR SMART SYSTEM C O )( S TM The CON•X•US mobile communication platform allows SMART SYSTEM r, �"��"�. to go where no other boiler has gone before: CON•X•US provides the ability to monitor and manage multiple Knight `',, heating boilers without ever stepping into the mechanical rooms. CON•X•US will send alerts via text or e-mail notifying of changes in t system status,and anytime,from anywhere,a user can check system status and re-program any boiler function.Once downloaded,the free CON•X•US mobile application allows for remote access to all SMART SYSTEM functions using an Internet-capable device. 'CON•X-US control board sold separately. I NEW SELECTABLE CASCADE OPTIONS When multiple KNIGHT boilers are installed together, the SMART SYSTEM built-in sequencer can be set for"Lead-Lag" cascade or"Efficiency Optimized" cascade operation. LEAD-LAG CASCADE EFFICIENCY OPTIMIZED CASCADE * _L_ I I 1 1 40) __ I ,_ __ Jill ill II .�Ir lir' �ii I� ,.___A_______, ,, ,, ������,. ` J� J,______, The"lead"boiler modulates with demand to capacity. This feature optimizes the modulation capabilities of the As demand increases,additional boilers fire and modulate to Boiler Plant while evenly distributing run time across all capacity.This continues,with additional boilers firing and cascaded boilers. Every 24 hours the SMART SYSTEM modulating to capacity until all units are operating. Every 24 automatically shifts the 1st boiler on role to the next in hours,the SMART SYSTEM automatically shifts the lead boiler the sequence,distributing run time equally. role to the next in the sequence,distributing lead-lag runtimes equally. SMART SYSTEM Cascade allows 2-8 boilers to be sequenced. KNIGHT° WALL-MOUNT BOILER DIMENSIONS AND SPECIFICATIONS I LOW VOLTAGE ELECTRICAL AIR CONNECTIONS N INLET M Gllgit HIGH VOLTAGE �� Q ELECTRICAL L - ro. O >a®0 0 CONNECTIONS R, �J FLUE ,_ I fe; INLET ®® DRAIN ENSATE A "Z- 0 (al @ RELIEF j D VALVE E F OUTLET G I 1 I _ I t -- 1 ■ ! H GAS 1 ,� - I g c J ToP RIGHT BorroM KNIGHT HEATING BOILER DIMENSIONS AND SPECIFICATIONS Input Heatin Model Max. Min. *AFUE Capacity Net A B C D E F G H I I K L M N 0 Gas Water Air Vent Shipping Number MBH MBH % MBH MBH Conn.Conn. Inlet Size Wt.(Ibs.) WHN055 55 11 95.0 51 44 33-1/4"18-1/2" 16" 11-3/4" 10-1/2" 6-1/2" 4" 1-1/2" 3" 14-1/2" 5-3/4" 4" 3" 16-1/4"5" 1/2" 1" 2" 2" 139 WHN085 85 17 95.0 79 69 33-1/4"18-1/2" 16" 11-3/4" 10-1/2" 6-1/2" 4" 1-1/2" 3" 14-1/2" 5-3/4" 4" 3" 16-1/4"5" 1/2" 1" 2" 2" 142 WHN110 110 22 95.0 102 89 33-1/4"18-1/2" 19" 14-1/2" 10-3/4" 7-3/4" 7-3/4" 2-1/4" 10" 15-1/2" 5" 3-1/4"3" 16-1/2"2-3/4" 1/2" 1" 3" 3" 159 WHN155 155 31 95.0 144 125 33-1/4"18-1/2" 19" 14-1/2" 10-3/4" 7-3/4" 7-3/4" 2-1/4" 10' 15-1/2" 5" 3-1/4"3" 16-1/2"2-3/4" 1/2" 1" 3" 3" 166 WHN199 199.9 40 95.0 185 161 33-1/4"18-1/2" 19" 14-1/2" 11-3/4" 8" 8" 1-1/4" 10' 16-3/4" 4-3/4" 3-1/4"2-3/4"16-1/2"3" 1/2" 1-1/4" 3" 3" 175 WHN285 285 57 95.0 264 229 33-1/4"18-1/2" 19" 14-1/2" 11-3/4" 8" 8" 1-1/4" 10' 16-3/4" 4-3/4" 3-1/4"2-3/4"16-1/2"3" 1/Z' 1-1/4" 3" 3" 184 WHN399 399 80 94.4 377 328 35-1/2"25" 21-3/4"17-1/Z' 12-1/2" 9-1/4" 9-1/2" 2-1/4" 13-1/4" 21-1/2" 9" 4-3/4"4" 22-1/2"3-3/4" 3/4" 1-1/Z' 4" 4" 213 Notes:Indoor installation only.All information subject to change.Change"N"to"L"for LP gas models.*WHN399 value is Thermal Efficiency SMART SYSTEM- FEATURES STANDARD FEATURES >SMART SYSTEM Digital Operating Control >Access to BMS Settings through Graphic >ENERGY STAR Most Efficient Recognition§ LCD Display Multi-Color Graphic LCD Display >95%DOE AFUE Efficiency5 Dial and Soft Ke s >High-Voltage Terminal Strip with Navigation Y >Modulating Burner with 5:1 Turndown >Three Boiler Set point Temperature Inputs 120 VAC/60 Hertz/1 Phase Power Supply P P P Direct-Spark Ignition Plus Domestic Hot Water Prioritization Three Sets of Pump Contacts >Low Voltage Terminal Strip Low-NOx Operation >Built-in Cascading Sequencer for Field Convertible from Natural to LP Gas up to 8 Boilers 24 VAC Device Relay Multiple Size Boiler Cascade Proving Switch Contacts >ASME Stainless Steel Heat Exchanger Lead Lag Flow Switch Contacts 30 psi ASME Relief Valve Alarm on AnyFailure Contacts >Vertical&Horizontal Direct-Vent Efficiency Optimization PVC,CPVC,Polypropylene or SS Venting up to Front End Loading Capability with Copper Fin II Runtime Contacts 100 feet >Outdoor Reset Control with Outdoor DHW Thermostat Contacts Air Sensor 3 Space Heat Thermostat Contacts >Smart System Control Programmable for Three Reset System Sensor Contacts >Condensate Trap Temperature Inputs DHW Tank Sensor Contacts >Other Features >Programmable System Efficiency Optimizers Outdoor Air Sensor Contacts Automatic Reset High Limit Night Setback Cascade Contacts Adjustable High Limit w/Manual Reset DHW Night Setback* 0-10 VDC BMS External Control Contact Boiler Circulating Pump Anti-Cycling 0-10 VDC Boiler Rate Output Contacts Wall-Mount Bracket Outdoor Air Reset Curve 0-10 VDC Variable Speed System Pump Signal Zero Clearances to Combustible Materials Input* 12-Year Limited Warranty Ramp Delay Boost Temperature&Time 0-10 VDC Signal to ontrol Variable (SeeeaWPartsty fora Details) pSpeed Boiler Pump* y >Three Pump Control Modbus Contacts OPTIONAL EQUIPMENT System Pump with Parameter for >Time Clock CON-X-US Remote Connectivity Continuous Operation >Data Logging Modbus Communication Boiler Pump with Variable Speed Hours Running,SpaceHeatingFlow Switch Pump Control* Low-Water Cutoff w Manual Reset&Test Domestic Hot Water Pump Hours Running,Domestic Hot Water / Ignition Attempts Alarm Bell >Domestic Hot Water Prioritization Last 10 Lockouts Concentric Vent Kit DHW tank piped with priority in >Maintenance Reminder SMART SYSTEM PC Software the boiler loop Condensate Neutralization Kit DHW tank piped as a zone in the Custom Maintenance Reminder with Contractor P p Contact Information BMS Gateway to LON or BacNet system with the pumps controlled by the Smart System Installer Ability to De-activate Multi-Temperature Loop Control DHW Modulation Limiting Service Reminder Sidewall Vent Termination Separately Adjustable Space Heat/DHW >Low-Water Flow Safety Control&Indication Floor Stand Switching Times* >Password Security Wireless Outdoor Sensor >Building Management System Integration >Customizable Freeze Protection Parameters FIRING CODES 0-10 VDC Input to Control Modulation >M9 Standard Construction or Set Point >M7 California Code 0-10 VDC Modulation Rate Output *Exclusive feature,available only rom Lochin ar 0-10 VDC Input to Enable/Disable call for heat §WHN 55-285 o 1 only E("E Lochinvar.LL Patent Pending lit_Loe libriar 0 L00 anon, x SimpsonParkway oesi,N ,I, 1� Lebanon,Tennessee 37090 r�Most ENioient , / P,615.889.8900/F:615.547.1000 AMR: t n CERTIFIED- rr 2U1g I, e .l HIGH EFFICIENCY BOILERS&WATER HEATERS lfi El El 0 Lochinvar.com ®'""'"""""°' E°® I,, FEO. H WHN-04 (Reprint WHN-o4 5/15) PDP-2.5M-9/15-Printed in U.S.A. ; 1�11C ^'� �•<il KNIGHT®WALL MOUNT BOILER PRODUCT SUMMARY (WHM 55,000-399,999 BTU/HR WH-055 WH-085 WH-110 WH-155 WH-199 WH-285 WH-399 WATER GALLON CAPACITY 2.5 2.5 3.5 3.5 5.0 5.0 6.5 HEATING SURFACE(SQ.FT.) 5.92 8.33 10.00 14.07 15.66 21.60 36.58 WATER CONNECTIONS 1" 1" 1" 1" 1-1/4" 1-1/4" 1-1/2" 20°F AT WATER FLOW(GPM) 5 8 10 15 19 27 38 HEAD LOSS(FT.OF HD.) 0.27 0.94 1.53 3.50 1.13 2.42 1.42 35°F AT WATER FLOW(GPM) 3 5 6 9 11 16 22 HEAD LOSS(FT.OF HD.) 0.10 0.37 0.55 1.45 0.38 0.85 0.48 MAX.WORKING PRESSURE(PSI) 80 80 80 80 80 80 80 #OF RELIEF VALVES 1 1 1 1 1 1 1 RELIEF VALVE SIZE 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" RELIEF VALVE RATING(MBH) 535 535 535 535 535 535 535 RELIEF VALVE PRESSURE RATING(PSI) 30 30 30 30 30 30 30 GAS INLET CONNECTION 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 3/4" MAX.INLET PRESSURE,NAT 14.0"w.c. 14.0"w.c. 14.0"w.c. 14.0"w.c. 14.0"w.c. 14.0" w.c. 14.0"w.c. MIN.INLET PRESSURE,NAT 4.0"w.c. 4.0"w.c. 4.0"w.c. 4.0"w.c. 4.0"w.c. 4.0"w.c. 4.0"w.c. MAX.INLET PRESSURE,LP 14.0"w.c. 14.0"w.c. 14.0"w.c. 14.0"w.c. 14.0"w.c. 14.0"w.c. 14.0"w.c. MIN.INLET PRESSURE,LP 8.0"w.c. 8.0"w.c. 8.0"w.c. 8.0"w.c. 8.0"w.c. 8.0"w.c. 8.0"w.c. BTU/HR INPUT 55,000 85,000 110,000 155,000 199,999 285,000 399,999 BTU/HR OUTPUT(HIGH FIRE) 52,250 80,750 104,500 147,250 189,999 270,750 379,999 BTU/HR OUTPUT(LOW FIRE) 10,450 16,150 20,900 29,450 38,000 54,150 76,000 ELECTRICAL VOLTAGE/HEATER 120 120 120 120 120 120 120 VOLTAGE/CONTROL 24 24 24 24 24 24 24 TOTAL AMPS 0.5 0.5 0.5 0.5 1.5 1.5 2.0 #OF ELECTRICAL CONNECTIONS 1 1 1 1 1 1 1 DIMENSIONS HEIGHT 33-1/4" 33-1/4" 33-1/4" 33-1/4" 33-1/4" 33-1/4" 35-1/2" WIDTH 18-1/2" 18-1/2" 18-1/2" 18-1/2" 18-1/2" 18-1/2" 25" DEPTH 16" 16" 19" 19" 19" 19" 21-3/4" SERVICE CLEARANCES FRONT 24" 24" 24" 24" 24" 24" 24" BOTTOM 24" 24" 24" 24" 24" 24" 24" RIGHT SIDE 0" 0" 0" 0" 0" 0" 0" LEFT SIDE 24" 24" 24" 24" 24" 24" 24" TOP 6" 6" 6" 6" 6" 6" 6" DIRECT VENTING SIZE 2" 2" 3" 3" 3" 3" 4" VENT CATEGORY IV IV IV IV IV IV IV VENT MATERIAL PVC/CPVC/SS PVC/CPVC/SS PVC/CPVC/SS PVC/CPVC/SS PVC/CPVC/SS PVC/CPVC/SS PVC/CPVC/SS Lochinvar,LLC•300 Maddox Simpson Pkwy•Lebanon,TN 37090•615-889-8900/Fax:615-547-1000 www.Lochinvar.com WH-PS-02 i u l2-Printed in U.S.A. RECEIVED 10/09/18 ASPEN BUILDING DEPARTMENT AIR CONDITIONERS LENNOX) xC�6 ELITE° Series R-410A- Two-Stage Compressor PRODUCT SPECIFICATIONS Bulletin No.210465 September 2014 Supersedes August 2014 i ' er ,. IQ es 0 0 = C ak,, 0 o LENNOX . 1 !!!t e-- t--- !!!A ___-.. ...., 0 Opa' � � ooC , A 00110 ENERGY STAR SEER up to 17.00 2 to 5 Tons Cooling Capacity - 23,000 to 57,500 Btuh MODEL NUMBER INDENTIFICATION X C16 - 036 - 230 - 5 Refrigerant Type T T - Minor Revision Number X=R-410A Unit Type Voltage C=Air Conditioner 230=208/230V-1 phase-60hz Series Nominal Cooling Capacity 024=2 tons 0 =3tons RECEIVED 04848=4 tons RECEIVED 060=5 tons 10/09/18 ASPEN BUILDING DEPARTMENT FEATURES CONTENTS �� - AHRI System Matches 9 ` ,, �� L --- - Dimensions 7 ;yam Electrical Data 5 F i. Features 24 Field Wiring 6 Installation Clearances 6Model Number Indentification 1 Optional Accessories 5Outdoor Sound Data 6Specifications 5 00 0 •WARRANTY 01 I • 00 Compressor- limited warranty for ten years in residential installations and five years in non-residential •installations. /other covered components-five years inresidential installations and one year in non-residential ©installations.Refer to Lennox Equipment Limited Warranty certificate $! y- All O+' included with unit for specific details. o /I ler . APPROVALS AHRI Certified to AHRI Standard 210/240-2008. Units shipped completely factory assembled, piped, and Sound rated in Lennox reverberant sound test room wired. Each unit is test operated at the factory insuring in accordance with test conditions included in AHRI proper operation. Standard 270-2008. Installer must set air conditioner, connect refrigerant Tested in the Lennox Research Laboratory lines, and make electrical connections to complete job. environmental test room. Rated according to U.S. Department of Energy (DOE) REFRIGERATION SYSTEM test procedures. R-410A Refrigerant Air conditioners and components within bonded for Non-chlorine, ozone friendly, R-410A. grounding to meet safety standards for servicing Unit pre-charged with refrigerant. LL 1 OA 11 required by UL and CEC. See Specification table. Units are ETL certified for the U.S. and Canada. 0 Outdoor Coil Fan ISO 9001 Registered Manufacturing Quality System. Direct drive fan moves large air volumes uniformly ENERGY STAR°certified units are designed to use less through entire condenser coil for high refrigerant cooling energy, help save money on utility bills, and help protect capacity. 048 models have a variable-speed outdoor fan the environment.. motor for quiet operation. For expanded ratings, see www.lennoxdavenet.com. Vertical air discharge minimizes operating sounds and eliminates damage to lawn and shrubs. APPLICATIONS Fan motor has sleeve bearings and is inherently SEER up to 17.20. protected. 2 through 5 ton. Motor totally enclosed for maximum protection from Single phase power supply. weather, dust and corrosion Sound levels as low as 74 dB. Fan guard constructed of corrosion-resistant PVC Vertical air discharge allows concealment behind shrubs (polyvinyl chloride)coated steel. at grade level or out of sight on a roof. Fan service access accomplished by removal of fan Matching add-on furnace indoor coils or air handlers guard. provide a wide range of cooling capacities and RECEIVED applications. See AHRI System Matches. See Indoor Coils and Air Handlers tab sections for data. 10/0 9/18 XC16-2 to 5 Ton Air Conditioner /Page 2 ASPEN BUILDING DEPARTMENT FEATURES REFRIGERATION SYSTEM (continued) COMPRESSOR 0 Copper Tube/Enhanced Fin Coil 0 Copeland Scroll Ultra TechTM Two-Stage Compressor Lennox designed and fabricated coil. Compressor features u.m�°.. no,m°y seal Ripple-edged aluminum fins. high efficiency with °Pe1a1ed°u a uniform suction flow, Copper tube construction. constant discharge °Lef°a' I check valve Lanced finsprovide maximum exposure of fin surface to p flow, high volumetric n= air stream resultingin excellent heat transfer. Scroll set efficiency and quiet Shutdown +�.k, Fin collars grip tubing for maximum contact area. operation. device Motor pro- Flared shoulder tubing connections/silver soldering Compressor consists Ht° construction. of two involute spiral °°a" H, scrolls matched 4.. motor r" P" Coil is factory tested under high pressure to insure ° leakproof construction. together to generate POE lubricant opti a series of crescent ' °°°" Entire coil is accessible for cleaning. shaped gas pockets ' � 0 High Pressure Switch between them. _ Shuts off unit if abnormal operating conditions cause the During compression, discharge pressure to rise above setting. one scroll remains Protects compressor from excessive condensing stationary while the pressure. other scroll orbits around it. Auto-reset. Gas is drawn into the outer pocket, the pocket is sealed as the scroll rotates. 0 Low Pressure Switch As the spiral movement continues, gas pockets are Shuts off unit if suction pressure falls below setting. pushed to the center of the scrolls. Volume between the Provides loss of charge and freeze-up protection. pockets is simultaneously reduced. Auto-reset. When the pocket reaches the center, gas is now at 0 Hi-Capacity Liquid Line Drier high pressure and is forced out of a port located in the Factory installed in the liquid line, the drier traps center of the fixed scrolls. During compression, several moisture or dirt that could contaminate the refrigerant pockets are compressed simultaneously resulting in a system. smooth continuous compression cycle. 100% molecular-sieve bead type drier. Continuous flank contact, maintained by centrifugal force, minimizes gas leakage and maximizes efficiency. Optional Accessories Scroll compressor is tolerant to the effects of slugging Expansion Valve Kits and contaminants. If this occurs, scrolls separate, Must be ordered extra and field installed on certain allowing liquid or contaminants to to be worked toward indoor units. See TXV Usage table. the center and discharged. Chatleff style fitting. During the compression process, there are several pockets in the scroll that are compressing gas. Freezestat Modulation is achieved by venting a portion of the gas Installs on or near the discharge line of the indoor coil or in the first suction pocket back to the low side of the on the suction line. compressor thereby reducing the effective displacement Senses suction line temperature and cycles the of the compressor. compressor off when suction line temperature falls A 24-volt DC solenoid valve inside the compressor below it's setpoint. °R;.q°" , -;,�°,�a ,;;-, • controls staging. When the 3-way Opens at 29°F and closes at 58°F. i;'� solenoid is energized it moves the WO/ lift ring assembly to block the Refrigerant Line Kits 1111. ports and the compressor Refrigerant lines (suction & liquid)are shipped R,"g ,.,_�„ operates at full load or 100% refrigeration clean. Lines are cleaned, dried, w" capacity. When the solenoid is pressurized, and sealed at factory. 1 4 de-energized the lift ring assembly Suction line fully insulated. moves to unblock the compressor L15 lines are stubbed at both ends. ports and the compressor operates at part-load or See Specifications table for selection. approximately 67% of its full-load capacity. Not available for-060 model and must be field The "loading" and "unloading" of the ivutor._ga..w E s1 done"on the fly"without shutting off t �sircgle°-p'• �f1 fabricated. compressor motor between stages. Low gas pulses during compression reduces/0 9/18 operational sound levels. c XC16-2 to 5 Ton AiM? NT FEATURES COMPRESSOR (continued) Indoor Blower Speed Relay Compressor motor is internally protected from Relay kit provides optimum humidity control conditions excessive current and temperature. by automatically reducing indoor blower speed during Compressor is installed in the unit on specially continuous fan or first-stage compressor operation. formulated, resilient rubber mounts for better sound Low Ambient Kit dampening and vibration free operation. Air conditioner will operate satisfactorily down to 45°F Crankcase Heater(048-060 models only) outdoor air temperature without any additional controls. Crankcase heater prevents migration of liquid Kit can be added in the field enabling unit to operate refrigerant into compressor and ensures proper properly down to 30°F. compressor lubrication. A Freezestat and optional Crankcase Heater(024-036) should be installed on compressors equipped with a low Optional Accessories ambient kit. Crankcase Heater(Optional for 024-036 models) A Compressor Low Ambient Cut-Off should be added to Crankcase heater prevents migration of liquid terminate compressor operation below recommended refrigerant into compressor and ensures proper operation conditions. compressor lubrication. Thermostat Compressor Hard Start Kit Thermostat not furnished with unit. See Thermostat Single-phase units are equipped with a PSC bulletins in Controls Section and Lennox Price Book. compressor motor. This type of motor normally does not CABINET need a potential relay and start capacitor. 0 Heavy-gauge steel construction In conditions such as low voltage, kit may be required to Pre-painted cabinet finish. increase the compressor starting torque. Control box is conveniently located with all controls Hard start kit is required in applications where the factory wired. supply voltage is less than 230V. Large removable panel provides service access. Drainage holes are provided in base section for CONTROLS moisture removal. Optional Accessories High density polyethylene unit support feet raise the unit off of the mounting surface, away from damaging Blower Relay Kit moisture. (For Use With EL195E and ML180E Gas Furnaces) Allows furnace blower speed changes when matched PermaGuardTM Unit Base with two-stage air conditioners. Durable zinc-coated base section resists rust and corrosion. ComfortSense®7000 Touchscreen Thermostat Electronic 7-day, universal, 0 SmartHinge- Louvered Coil Protection multi-stage, programmable, Steel louvered panels touchscreen thermostat. _ provides complete coil 4 Heat/2 Cool. - on,n"F � o protection. .- Auto-changeover. � U `o Panels are hinged to allow Controls humidity during easy cleaning and servicing cooling mode. of coils. y ,� Offers enhanced capabilities Panels may be completely including humidification/ removed. dehumidification /dewpoint measurement and control, Interlocking tabs and slots HumiditroF control, and equipment maintenance assure tight fit on cabinet. reminders. 0 Refrigerant Line Connections, Electrical Inlets and Easy-to-use, menu driven thermostat with a back-lit, Service Valves LCD touchscreen. Suction and liquid lines are located on corner of unit Remote outdoor temperature sensor(optional) allows cabinet and are made with sweat connections. See the thermostat to display outdoor temperature. Required dimension drawing. in dual fuel and HumiditroF applications. Fully serviceable brass service valves prevent corrosion See the ComfortSense 7000 Product Specifications and provide access to refrigerant system. Suction valve bulletin in the Controls section for more information. can be fully shut off, while liquid valve maEIVED Indoor Blower Off Delay Relay seated to manage refrigerant charge whiles i#j Delays the indoor blower-off time during the cooling system. 0/0 9/18 cycle. Refrigerant line connections and field wiring inlets are located in one central area of the cabinet. See ASPEN XC16-2 to 5 Ton Air Conditioner /Page 4 dimension drawing. BUILDING DEPARTMENT SPECIFICATIONS General Model No. XC16-024 XC16-036 XC16-048 XC16-060 Data Nominal Tonnage 2 3 4 5 Connections Liquid line (o.d.)-in. 3/8 3/8 3/8 3/8 (sweat) Suction line (o.d.)-in. 3/4 _ 7/8 7/8 1-1/8 Refrigerant 1 R-410A charge furnished 7 lbs. 5 oz. 8 lbs. 6 oz. 10 lbs. 7 oz. 12 lbs. 1 oz. Outdoor Net face area-sq.ft. Outer coil 24.50 16.33 21.00 29.09 Coil Inner coil --- 15.76 20.27 28.24 Tube diameter-in. 5/16 5/16 5/16 5/16 No. of rows 1 2 2 2 Fins per inch 26 22 22 22 Outdoor Diameter-in. 22 22 22 26 Fan No. of blades 4 4 4 3 Motor hp 1/6 1/4 1/3 1/3 Cfm- 1st stage 3260 3500 3190 4325 2nd stage --- --- 3700 --- Rpm- 1st stage 840 825 705 865 2nd stage --- --- 820 --- Watts- 1st stage 220 300 165 240 2nd stage --- --- 260 --- Shipping Data- lbs. 1 pkg. 249 243 268 332 ELECTRICAL DATA Line voltage data-60hz 4 230V-1 ph 4 230V-1 ph 4 230V-1 ph 4 230V-1 ph 2 Maximum overcurrent protection (amps) 25 35 50 60 3 Minimum circuit ampacity 15.7 20.8 29.2 35.6 Compressor Rated load amps 11.66 15.25 21.15 27.1 Locked rotor amps 58.3 83 104 152.9 Power factor 0.98 0.99 0.99 0.99 Outdoor Fan Full load amps 1.0 1.7 2.8 1.8 Motor Locked Rotor amps 1.9 3.1 N/A 2.9 OPTIONAL ACCESSORIES - ORDER SEPARATELY Blower Relay Kit 85W66 • (for EL195E and ML180E gas furnaces) ComfortSense®7000 Thermostat Y2081 • • Outdoor Temperature Sensor-for X2658 • • ComfortSense 7000 Thermostat Compressor Crankcase Heater 93M04 • • Factory • Compressor Hard Start Kit-Required in 63W22 • applications with less than 230V 10J42 • 63W24 • Compressor Low Ambient Cut-Off 45F08 • Compressor Time-Off Control 47J27 • • Freezestat 3/8 in. tubing 93G35 • 5/8 in. tubing 50A93 • • Indoor Blower Off Delay Relay 58M81 • Indoor Blower Speed Relay 40K58 • 5 Low Ambient Kit 34M72 • 68M04 • Refrigerant L15-41-20 L15-41-40 • Line Sets L15-41-30 L15-41-50 L15-65-30 L15-65-40 • L 15-65-50 Field Fabricate • NOTE-Extremes of operating range are plus 10%and minus 5%of line voltage. Refrigerant charge sufficient for 15 ft.length of refrigerant lines.For longer line set requirements see the Installation Instructions for information about line set len th and additional refrigerant charge required. RE 4 E I�/ED 2 HACR type breaker or fuse. 3 Refer to National or Canadian Electrical Code manual to determine wire,fuse and disconnect size requirements. 4 Hard Start Kit is required in applications where the supply voltage is less than 230V. 10/0 9/1 8 5 Crankcase Heater(if not furnished)and Freezestat are recommended with Low Ambient Kit. Ck.i XC16-2 to 5 Ton Ai[31Calf ? NT OUTDOOR SOUND DATA Octave Band Linear Sound Power Levels dB, re 10 12 Watts 'Sound ' Unit Center Frequency-HZ Rating Model No. Number 63 125 250 500 1000 2000 4000 8000 (dB) XC16-024 77.5 66.6 65.5 66.4 62.7 57.9 55.1 55.5 73 XC 16-036 77.8 70.6 67.9 66.7 63.1 57.5 54.7 55.4 74 XC16-048 74.6 64.7 64.1 65.8 65.2 60.3 56.1 53.7 74 XC16-060 72.6 68.9 67 66.4 67.4 58.9 57.3 52.5 74 NOTE-the octave sound power data does not include tonal correction. 1 Tested according to AHRI Standard 270-2008 test conditions. FIELD WIRING r DISCONNECT 1 r THERMOSTAT, r DISCONNECT 1 B WITCH I I (Optional) I I WITCH L ( y Others) j L 1 L (By Others) J i CI A-Two Wire Power(not furnished) 0 CI B-Two Power(not furnished). See Electrical Data C- Four Wire Low Voltage(not furnished). 18 ga. minimum D-Six Wire Low Voltage(not furnished). 18 ga. minimum OAll wiring must conform to NEC or CEC and local electrical codes. LENNOX C LENNOX AIR / HEATING UNIT CONDITIONER OR AIR HANDLER UNIT INSTALLATION CLEARANCES - INCHES (MM) See NOTES NOTES: Service clearance of 30 in. (762 mm)must be maintained on one of the sides adjacent to the control box.((((iJ))))$j))) Clearance to one of the other three sides must be 36 in. (914 mm) See See- Clearance to one of the remaining two sides may be 12 in. (305 NOTES NOTES mm)and the final side may be 6 in. (152 mm). _ ./ A clearance of 24 in. (610 mm)must be maintained between two 4 units. See NOTES Control Box 48 in. (1219 mm)clearance required on top of unit. RECEIVED 10/09/18 XC16-2 to 5 Ton Air Conditioner /Page 6 / EPA BUILDINGG DEPARTMENT DIMENSIONS - INCHES (MM) 0 ))))))) SUCTION LINE 4, CONNECTION LIQUID LINE TOP VIEW CONNECTION DISCHARGE AIRt 11 B ' r r 0 0 0 0 0 o LIQUID LINE 0 0 0 0 0 o CONNECTION =00000 ELECTRICAL A o0000 0 0 0 0 o INLETS _ 00000 SUCTION LINE o0000 000000 7��CONNECTION o0000 00000 2(51) 4� o0000 o o o o L7��f 4-1/4(108) 4-3/4 0 00 u u (12/1) . LJ „ LJ SIDE VIEW 1 (25) END VIEW UNIT SUPPORT UNIT SUPPORT FEET \ FEET ici ::) if _i_ .... 0 i t C>.---0 0 16-7/8 26-7/8 (352)13-7/8 0 0 0 20-5/8 (429) 0 0 0 (683) (524) i ^ 00040 0 IN) I - 1-. ® % 1 8 3/4 7-3/4 (222) (1+7) (114) 3-3/4(95) I 4 3-1/4 _I 27-1/8 t 3-5/8 - ..--30-3/4(781) ► t (83) (689) (92) 3-1/8 4-5/8 (79) (117) XC16-024 TO -048 BASE SECTION XC16-060 BASE SECTION (Medium) (Large) A B C Model No. in. mm in. mm in. mm XC16-024 45 1143 30-1/2 775 35 889 XC16-036 31 787 30-1/2 775 35 889 XC16-048 39 991 30-1/2 775 35 889 RECEIVEt XC16-060 45 1143 35-1/2 902 39-1/2 1003 10/09/18 e C XC16-2to5 Ton Ai�csoli Ut ONT TXV USAGE *TXV SUBSTITUTIONS Model No. Order No. Indoor Coils/Air Handlers with factory installed expansion XC16-024 37L51 valves that require field replacement XC16-036 37L51 Model No. Indoor Coil or Air Factory Replacement Handler TXV TXV XC16-048 91M02 XC16-036 CX34-42 49L25 37L51 XC16-060 91M02 CX34 upflow coils and all Lennox air handlers are shipped with a factory XC16-036 CX34-43 49L25 37L51 installed TXV.In most cases,no change out of the valve is needed. XC16-036 CX34-44/48 49L25 37L51 If a change out is required it will be listed in the"TXV SUBSTITUTIONS"table. The correct TXV must be ordered and field installed. XC16-036 CX34-49 91 M02 37L51 C33,CH33 and CH35 coils-Factory installed orifice must be replaced with the expansion valve listed. XC16 036 CBX27UH 042 91 M02 37L51 CR33 and CH23 coils-Use the expansion valve listed. XC16-036 CBX32M-042 91 M02 37L51 XC16-036 CBX32MV-048 91 M02 37L51 XC16-036 CBX4OUHV-042 91 M02 37L51 MOST POPULAR MATCHES XC16-036 CBX4OUHV-048 91M02 37L51 Outdoor Unit Indoor Unit `Factory installed expansion valve on the indoor coil or air handler shown must Model No. Model No be replaced with the expansion valve listed(ordered separately). XC16-024 CX34-36B with SL280UH090V36B XC16-036 CX34-43C with SL280UH090V60C XC16-048 CX34-62C with SL280UH090V60C XC16-060 CX34-62C with SL280UH090V60C AHRI STANDARD 210/240 Cooling or heating capacities are net values, including Units which do not have an indoor air-circulating blower the effects of blower motor heat, and do not include furnished as part of the model, i.e., split system with supplementary heat. Power input is the total power input indoor coil only, is established by subtracting from the to the compressor(s) and fan(s), plus any controls and total cooling capacity 1250 Btu/h per 1,000 cfm, and by other items required as part of the system for normal adding the same amount to the heating capacity. Total operation. power input for both heating and cooling is increased by 365 W per 1,000 cfm of indoor air circulated. RECEIVED 10/09/18 XC16-2 to 5 Ton Air Conditioner /Page 8 ASPEN BUILDING DEPARTMENT AHRI SYSTEM MATCHES NOTE- For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model Expansion Coil or AHRI No. Device Capacity SEER EER Air Handler Furnace Reference XC16-024-230 TXV 23,800 14.00 11.50 033-19 6742549 X016-024-230 TXV 24,200 16.00 13.00 033-19 CBWMV-24B-040 6742592 X016-024-230 TXV 24,400 16.00 13.00 033-19 SL280UH070V36A 6742551 X016-024-230 TXV 23,600 15.00 12.50 033-24 EL296UH045XV36B 6742541 X016-024-230 TXV 23,600 15.50 12.50 033-24 SL280UH070V36A 6742543 X016-024-230 TXV 23,400 15.00 12.50 C33-24 SL280UH090V36B 6742545 XC16-024-230 TXV 23,600 15.00 12.50 033-24 SLP98UH070XV36B 6742547 X016-024-230 TXV 24,200 14.00 12.00 033-25 6742559 X016-024-230 TXV 24,800 16.00 13.00 033-25 EL296UH045XV36B 6742561 X016-024-230 TXV 24,800 16.00 13.00 033-25 SL280UH070V36A 6742553 X016-024-230 TXV 24,600 15.10 13.00 033-25 SL280UH090V36B 6742555 X016-024-230 TXV 24,600 16.00 13.00 033-25 SLP98UH070XV36B 6742557 XC16-024-230 TXV 24,000 15.50 12.50 033-30 EL296UH045XV36B 6742563 X016-024-230 TXV 24,600 14.50 12.00 033-31 6742567 XC16-024-230 TXV 25,200 16.00 13.50 033-31 EL296UH045XV36B 6742569 X016-024-230 TXV 25,200 17.00 13.00 033-31 SL280UH070V36A 6742565 XC16-024-230 TXV 25,400 17.00 13.50 033-31 SL280UH070XV36A 6742593 X016-024-230 TXV 25,000 16.00 13.50 033-31 SL280UH090V36B 6742571 XC16-024-230 TXV 25,200 16.00 13.50 033-31 SLP98UH070XV36B 6742573 X016-024-230 TXV 24,000 14.00 11.50 033-36 6742577 X016-024-230 TXV 24,600 16.00 13.00 033-36 CBWMV-24B-040 6742594 X016-024-230 TXV 24,600 16.00 13.00 033-36 EL296UH045XV36B 6742579 XC16-024-230 TXV 24,600 16.00 13.00 033-36 SL280UH070V36A 6742575 X016-024-230 TXV 24,800 16.00 13.00 033-36 SL280UH070XV36A 6742595 XC16-024-230 TXV 24,400 15.10 13.00 033-36 SL280UH090V36B 6742500 X016-024-230 TXV 24,600 16.00 13.00 033-36 SLP98UH070XV36B 6742581 X016-024-230 TXV 24,600 16.00 13.50 033-36 SLP98UH090XV36C 6742596 X016-024-230 TXV 24,800 14.50 12.20 033-38 6742585 XC16-024-230 TXV 25,400 16.00 13.50 033-38 EL296UH045XV36B 6742587 X016-024-230 TXV 25,400 17.00 13.50 033-38 SL280UH070V36A 6742583 X016-024-230 TXV 25,400 17.00 13.50 033-38 SL280UH070XV36A 6742597 X016-024-230 TXV 25,200 16.00 13.50 033-38 SL280UH090V36B 6742589 X016-024-230 TXV 25,200 16.00 13.50 033-38 SLP98UH070XV36B 6742591 X016-024-230 TXV 24,200 13.00 12.00 CBX25UH-024 6742598 X016-024-230 TXV 24,000 16.00 13.00 CBX25UHV-024 6970136 X016-024-230 TXV 25,000 16.00 13.50 CBX27UH-024 6742502 X016-024-230 TXV 25,200 17.00 13.50 CBX27UH-030 6742503 XC16-024-230 TXV 24,400 14.50 12.00 CBX32M-018/024 6742504 X016-024-230 TXV 24,400 15.50 12.20 CBX32MV-018/024 6742505 X016-024-230 TXV 24,600 15.50 12.50 CBX32MV-024/030 6742506 X016-024-230 TXV 24,800 16.00 12.50 CBX4OUHV-024 6742599 X016-024-230 TXV 24,800 15.50 13.00 CBX4OUHV-030 6742600 X016-024-230 TXV 23,000 13.00 11.00 0H23-31 6742507 X016-024-230 TXV 23,600 15.50 13.00 0H23-31 EL296UH070XV36B 6742601 X016-024-230 TXV 23,600 15.10 12.50 0H23-31 SL280UH070V36A 6742508 X016-024-230 TXV 23,800 16.00 12.50 0H23-31 SL280UH070XV36A 6742602 XC16-024-230 TXV 23,400 15.00 12.50 0H23-31 SL280UH090V3 � Ratings AHRI Certified to AHRI Standard 210/240(with 25 ft.of connecting refrigerant lines);95°F outdoor air temperature,80°F db/67°F wb y�E r All ratings include the use of a blower time delay relay(TDR).All Lennox variable-speed furnaces and Air Handlers have time delay capabilities.Other Furnaces and Air Handlers may require an optional time delay relay(58M81)for field installation.See furnace or air handler specifications to determine if relay is need/.0/0 9/1 8 Also see Expansion Valve Kit Usage Table. Ck\i XC16-2 to 5 Ton Ai[31Calf ? NT AHRI SYSTEM MATCHES NOTE-For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model Expansion Coil or AHRI No. Device Capacity SEER EER Air Handler Furnace Reference XC16-024-230 TXV 23,600 15.50 13.00 0H23-31 SLP98UHO7OXV36B 6742510 XC16-024-230 TXV 24,200 14.00 12.00 CH23-41 6742511 XC16-024-230 TXV 24,600 16.00 13.00 CH23-41 EL296UH070XV36B 6742603 XC16-024-230 TXV 24,800 16.00 13.00 CH23-41 SL280UH070V36A 6742512 XC16-024-230 TXV 24,800 16.00 13.00 CH23-41 SL280UH070XV36A 6742604 XC16-024-230 TXV 24,600 15.10 13.00 CH23-41 SL280UH090V36B 6742513 XC16-024-230 TXV 24,800 15.10 13.00 0H23-41 SL280UH090V48B 6742605 XC16-024-230 TXV 24,600 16.00 13.00 0H23-41 SLP98UHO7OXV36B 6742514 XC16-024-230 TXV 23,600 14.00 11.50 0H33-19 6742515 XC16-024-230 TXV 24,200 16.00 13.00 CH33-19 SL280UH070V36A 6742516 XC16-024-230 TXV 24,400 16.00 13.00 0H33-19 SL280UHO7OXV36A 6742606 XC16-024-230 TXV 23,600 14.00 11.50 0H33-24/30 6742517 XC16-024-230 TXV 24,200 16.00 12.50 0H33-24/30 SL280UH070V36A 6742518 XC16-024-230 TXV 24,600 16.00 13.00 0H33-25 EL296UH045XV36B 6742522 XC16-024-230 TXV 24,600 16.00 13.00 0H33-25 EL296UHO7OXV36B 6742607 XC16-024-230 TXV 24,800 16.00 13.00 0H33-25 SL280UH070V36A 6742520 XC16-024-230 TXV 25,000 16.00 13.00 0H33-25 SL280UH070XV36A 6742608 XC16-024-230 TXV 24,400 15.10 13.00 CH33-25 SL280UH090V36B 6742523 XC16-024-230 TXV 24,800 15.10 13.00 0H33-25 SL280UH090V48B 6742609 XC16-024-230 TXV 24,600 16.00 13.00 0H33-25 SLP98UHO7OXV36B 6742524 XC16-024-230 TXV 24,200 14.50 12.00 0H33-25A 6742519 XC16-024-230 TXV 24,000 14.00 11.50 CH33-25B 6742521 XC16-024-230 TXV 25,200 16.00 13.50 0H33-31 EL296UH045XV36B 6742528 XC16-024-230 TXV 25,200 17.00 13.50 CH33-31 EL296UH070XV36B 6742610 XC16-024-230 TXV 25,200 16.00 13.00 0H33-31 SL280UH070V36A 6742526 XC16-024-230 TXV 25,400 16.00 13.00 CH33-31 SL280UH070XV36A 6742611 XC16-024-230 TXV 25,200 16.00 13.50 CH33-31 SL280UH090V36B 6742529 XC16-024-230 TXV 25,400 16.00 13.00 CH33-31 SL280UH090V48B 6742612 XC16-024-230 TXV 25,200 16.00 13.50 CH33-31 SLP98UHO7OXV36B 6742530 XC16-024-230 TXV 24,600 14.50 12.00 CH33-31A 6742525 XC16-024-230 TXV 24,800 14.50 12.20 CH33-31B 6742527 XC16-024-230 TXV 24,600 16.00 13.00 CH33-36 EL296UH045XV36B 6742534 XC16-024-230 TXV 24,600 16.00 13.00 CH33-36 EL296UH070XV36B 6742613 XC16-024-230 TXV 24,600 16.00 13.00 CH33-36 SL280UH070V36A 6742532 XC16-024-230 TXV 24,600 16.00 13.00 CH33-36 SL280UH070XV36A 6742614 XC16-024-230 TXV 24,400 15.10 13.00 CH33-36 SL280UH090V36B 6742535 XC16-024-230 TXV 24,600 16.00 13.00 CH33-36 SLP98UH070XV36B 6742536 XC16-024-230 TXV 24,000 14.00 11.50 0H33-36A 6742531 XC16-024-230 TXV 24,000 14.00 11.50 0H33-36B 6742533 XC16-024-230 TXV 24,800 16.00 13.50 0H33-360 EL296UH090XV36C 6742615 XC16-024-230 TXV 24,800 16.50 13.50 0H33-36C SLP98UH090XV36C 6742616 XC16-024-230 TXV 23,800 14.00 11.50 0H35-18A 7165457 XC16-024-230 TXV 24,000 16.00 13.00 0H35-18A SL280UH070V36A 7165584 XC16-024-230 TXV 24,000 16.00 13.00 0H35-18A SL280UH070XV36A 7165458 XC16-024-230 TXV 24,000 14.50 12.00 0H35-24A 7165459 XC16-024-230 TXV 24,000 16.00 13.00 CH35-24A SL280UH070V36A 7165585 XC16-024-230 TXV 24,000 16.00 13.00 CH35-24A SL280UH070XV36A .,. Ratings AHRI Certified to AHRI Standard 210/240(with 25 ft.of connecting refrigerant lines);95°F outdoor air temperature,80°F db/67°F wb entering@'•_. !m �VE All ratings include the use of a blower time delay relay(TDR).All Lennox variable-speed furnaces and Air Handlers have time delay capabilities.Other Furnaces and Air Handlers may require an optional time delay relay(58M81)for field installation.See furnace or air handler specifications to determine if relay is needed. 10/0 9/1 8 Also see Expansion Valve Kit Usage Table. XC16-2 to 5 Ton Air Conditioner /Page 10 ASPEN BUILDING DEPARTMENT AHRI SYSTEM MATCHES NOTE- For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model Expansion Coil or AHRI No. Device Capacity SEER EER Air Handler Furnace Reference XC16-024-230 TXV 24,000 14.25 12.00 0H35-24B 7165461 XC16-024-230 TXV 24,000 16.00 13.00 0H35-24B EL296UH045XV36B 7165462 XC16-024-230 TXV 24,000 16.00 13.00 0H35-24B EL296UH070XV36B 7165463 XC16-024-230 TXV 24,000 15.10 13.00 0H35-24B SL280UH090V36B 7165586 XC16-024-230 TXV 24,000 15.10 13.00 0H35-24B SL280UH090V48B 7165464 XC16-024-230 TXV 24,000 16.00 13.00 CH35-24B SLP98UH070XV36B 7165587 XC16-024-230 TXV 24,000 14.50 12.20 0H35-30A 7165465 XC16-024-230 TXV 24,000 16.00 13.00 0H35-30A SL280UH070V36A 7165588 XC16-024-230 TXV 24,000 17.00 13.00 0H35-30A SL280UH070XV36A 7165466 XC16-024-230 TXV 24,000 14.50 12.20 0H35-30B 7165467 XC16-024-230 TXV 24,000 16.00 13.00 0H35-30B EL296UH045XV36B 7165468 XC16-024-230 TXV 24,000 17.00 13.00 0H35-30B EL296UH070XV36B 7165469 XC16-024-230 TXV 24,000 16.00 13.00 0H35-30B SL280UH090V36B 7165589 XC16-024-230 TXV 24,000 16.00 13.00 0H35-30B SL280UH090V48B 7165470 XC16-024-230 TXV 24,000 16.00 13.00 CH35-30B SLP98UH070XV36B 7165590 XC16-024-230 TXV 24,000 14.25 11.50 0H35-36A 7165471 XC16-024-230 TXV 24,000 16.00 13.00 0H35-36A SL280UH070V36A 7165591 XC16-024-230 TXV 24,000 16.00 13.00 0H35-36A SL280UH070XV36A 7165472 XC16-024-230 TXV 24,000 14.25 11.50 0H35-36B 7165473 XC16-024-230 TXV 24,000 16.00 13.00 0H35-36B EL296UH045XV36B 7165475 XC16-024-230 TXV 24,000 16.00 13.00 0H35-36B EL296UH070XV36B 7165476 XC16-024-230 TXV 24,000 15.10 13.00 0H35-36B SL280UH090V36B 7165592 XC16-024-230 TXV 24,000 16.00 13.00 0H35-36B SLP98UH070XV36B 7165593 XC16-024-230 TXV 24,000 14.25 11.50 0H35-360 7165474 XC16-024-230 TXV 24,000 16.00 13.00 0H35-360 EL296UH090XV36C 7165477 XC16-024-230 TXV 24,000 16.00 13.00 0H35-360 SLP98UH090XV36C 7165478 XC16-024-230 TXV 24,400 14.50 12.00 0R33-30/36 6742537 XC16-024-230 TXV 25,200 17.00 13.50 CR33-30/36 EL296DF045V36B 6742538 XC16-024-230 TXV 25,200 16.00 13.00 0R33-30/36 EL296DF070XV48B 6742539 XC16-024-230 TXV 25,200 16.00 13.00 0R33-30/36 SL280DF070V36A 6742830 XC16-024-230 TXV 24,600 16.00 13.50 0R33-30/36 SLP98DF070XV36B 6742617 XC16-024-230 TXV 25,000 16.00 13.50 0R33-30/36 SLP98DF090XV36C 6742618 XC16-024-230 TXV 23,000 13.00 11.00 0X34-18/24 6742619 XC16-024-230 TXV 23,600 15.00 12.50 0X34-18/24 CBWMV-24B-040 6742620 XC16-024-230 TXV 23,600 15.00 12.50 0X34-18/24 EL296UH045XV36B 6742540 XC16-024-230 TXV 23,600 15.50 12.50 CX34-18/24 EL296UH070XV36B 6742621 XC16-024-230 TXV 23,600 15.10 12.50 0X34-18/24 SL280UH070V36A 6742542 XC16-024-230 TXV 23,800 15.10 12.50 0X34-18/24 SL280UH070XV36A 6742622 XC16-024-230 TXV 23,400 14.50 12.50 0X34-18/24 SL280UH090V36B 6742544 XC16-024-230 TXV 23,600 15.00 12.50 0X34-18/24 SLP98UH070XV36B 6742546 XC16-024-230 TXV 23,800 14.00 11.50 0X34-19 6742548 XC16-024-230 TXV 24,400 16.00 13.00 0X34-19 SL280UH070V36A 6742550 XC16-024-230 TXV 24,600 16.00 13.00 0X34-19 SL280UH070XV36A 6742623 XC16-024-230 TXV 24,200 14.00 12.00 0X34-25 6742558 XC16-024-230 TXV 24,800 16.00 13.00 0X34-25 EL296UH045XV36B 6742560 XC16-024-230 TXV 24,800 16.00 13.50 0X34-25 EL296UH070XV36B 6742624 XC16 024 230 TXV 24,800 16.00 13.00 0X34 25 SL280UH070V3 ,, Ratings AHRI Certified to AHRI Standard 210/240(with 25 ft.of connecting refrigerant lines);95°F outdoor air temperature,80°F db/67°F wbaErili r �� All ratings include the use of a blower time delay relay(TDR).All Lennox variable-speed furnaces and Air Handlers have time delay capabilities.Other Furnaces and Air Handlers may require an optional time delay relay(58M81)for field installation.See furnace or air handler specifications to determine if relay is need.".O/O 9/1 8 Also see Expansion Valve Kit Usage Table. C1 (� XC16-2to5 Ton Air Bgp�i�j1p MENT AHRI SYSTEM MATCHES NOTE-For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model Expansion Coil or AHRI No. Device Capacity SEER EER Air Handler Furnace Reference XC16-024-230 TXV 24,800 16.00 13.00 0X34-25 SL280UH070XV36A 6742625 XC16-024-230 TXV 24,600 15.10 13.00 CX34-25 SL280UH090V36B 6742554 XC16-024-230 TXV 24,800 16.00 13.00 CX34-25 SL280UH090V48B 6742626 X016-024-230 TXV 24,600 16.00 13.00 CX34-25 SLP98UHO7OXV36B 6742556 XC16-024-230 TXV 24,000 15.50 12.50 CX34-30 EL296UH045XV36B 6742562 XC16-024-230 TXV 24,600 14.50 12.00 CX34-31 6742566 XC16-024-230 TXV 25,200 16.00 13.50 0X34-31 EL296UH045XV36B 6742568 XC16-024-230 TXV 25,200 16.00 13.50 0X34-31 EL296UH070XV36B 6742627 XC16-024-230 TXV 25,200 17.00 13.00 0X34-31 SL280UH070V36A 6742564 XC16-024-230 TXV 25,400 17.00 13.50 CX34-31 SL280UH070XV36A 6742628 XC16-024-230 TXV 25,000 16.00 13.50 0X34-31 SL280UH090V36B 6742570 XC16-024-230 TXV 25,200 16.00 13.00 0X34-31 SL280UH090V48B 6742629 XC16-024-230 TXV 25,200 16.00 13.50 0X34-31 SLP98UH070XV36B 6742572 XC16-024-230 TXV 24,000 14.00 11.50 0X34-36 6742576 XC16-024-230 TXV 24,600 16.00 13.00 0X34-36 CBWMV-24B-040 6742630 XC16-024-230 TXV 24,600 16.00 13.00 0X34-36 EL296UH045XV36B 6742578 X016-024-230 TXV 24,600 16.00 13.00 0X34-36 EL296UHO7OXV36B 6742631 XC16-024-230 TXV 24,600 16.00 13.50 CX34-36 EL296UH090XV36C 6742632 X016-024-230 TXV 24,600 16.00 13.00 0X34-36 SL280UH070V36A 6742574 XC16-024-230 TXV 24,800 16.00 13.00 0X34-36 SL280UH070XV36A 6742633 X016-024-230 TXV 24,400 16.00 13.00 0X34-36 SL280UH090V36B 6742499 XC16-024-230 TXV 24,600 16.00 13.00 CX34-36 SLP98UHO7OXV36B 6742580 X016-024-230 TXV 24,600 16.00 13.50 0X34-36 SLP98UHO9OXV36C 6742634 XC16-024-230 TXV 24,800 14.50 12.20 CX34-38 6742584 XC16-024-230 TXV 25,400 16.00 13.50 0X34-38 EL296UH045XV36B 6742586 XC16-024-230 TXV 25,200 17.00 13.50 CX34-38 EL296UH070XV36B 6742635 X016-024-230 TXV 25,400 17.00 13.50 CX34-38 SL280UH070V36A 6742582 XC16-024-230 TXV 25,400 17.00 13.50 CX34-38 SL280UH070XV36A 6742636 XC16-024-230 TXV 25,200 16.00 13.50 CX34-38 SL280UH090V36B 6742588 XC16-024-230 TXV 25,400 16.00 13.50 CX34-38 SL280UH090V48B 6742637 XC16-024-230 TXV 25,200 16.00 13.50 0X34-38 SLP98UH070XV36B 6742590 XC16-036-230 TXV 34,400 13.00 11.00 C33-36 6508029 XC16-036-230 TXV 34,800 15.00 12.00 C33-36 CBWMV-360-090 6508440 XC16-036-230 TXV 35,000 14.50 11.70 C33-36 EL180UH045E36A 6508445 XC16-036-230 TXV 35,000 15.00 11.70 C33-36 EL180UH070E36B 6508452 XC16-036-230 TXV 34,800 14.50 11.00 C33-36 EL195UH045XE36B 6508034 XC16-036-230 TXV 34,800 14.50 11.70 C33-36 EL195UH070XE36B 6508039 X016-036-230 TXV 34,600 14.50 11.00 C33-36 EL296UH045XE36B 6508552 XC16-036-230 TXV 34,800 15.00 11.70 033-36 EL296UH045XV36B 6508057 XC16-036-230 TXV 34,800 14.50 11.00 033-36 EL296UH070XE36B 6508558 XC16-036-230 TXV 34,800 15.00 12.00 033-36 EL296UHO9OXV48C 6508470 XC16-036-230 TXV 35,000 15.00 12.20 033-36 EL296UH110XV48C 6508063 XC16-036-230 TXV 35,400 15.00 12.20 033-36 EL296UH110XV60C 6508509 XC16-036-230 TXV 35,000 15.00 11.70 033-36 SL280UH070V36A 6508021 XC16-036-230 TXV 35,000 15.00 11.70 033-36 SL280UHO7OXV36A 6508476 XC16-036-230 TXV 35,200 15.00 12.00 033-36 SL280UH090V36B 6508069 XC16-036-230 TXV 35,000 15.00 12.00 033-36 SL280UH090V48B e,..,' Ratings AHRI Certified to AHRI Standard 210/240(with 25 ft.of connecting refrigerant lines);95°F outdoor air temperature,80°F db/67°F wb entering�@'••_. !m EVE D All ratings include the use of a blower time delay relay(TDR).All Lennox variable-speed furnaces and Air Handlers have time delay capabilities.Other Furnaces and Air Handlers may require an optional time delay relay(58M81)for field installation.See furnace or air handler specifications to determine if relay is needed. 10/0 9/1 8 Also see Expansion Valve Kit Usage Table. XC16-2 to 5 Ton Air Conditioner /Page 12 ASPEN BUILDING DEPARTMENT AHRI SYSTEM MATCHES NOTE- For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model Expansion Coil or AHRI No. Device Capacity SEER EER Air Handler Furnace Reference XC16-036-230 TXV 35,400 15.00 12.00 033-36 SL280UH090V60C 6508082 X016-036-230 TXV 35,200 15.00 12.20 C33-36 SL280UH090XV48B 6508482 X016-036-230 TXV 35,400 15.10 12.00 033-36 SL280UH090XV60C 6508488 X016-036-230 TXV 35,200 15.00 12.00 C33-36 SL280UH110V60C 6508088 X016-036-230 TXV 35,400 15.00 12.00 033-36 SL280UH110XV60C 6508495 XC16-036-230 TXV 35,000 15.00 11.70 C33-36 SLP98UH070XV36B 6508094 XC16-036-230 TXV 35,000 15.00 12.00 033-36 SLP98UH090XV36C 6508101 X016-036-230 TXV 35,200 15.00 12.00 033-36 SLP98UHO9OXV48C 6508107 X016-036-230 TXV 35,600 15.00 12.00 033-36 SLP98UH090XV60C 6508112 X016-036-230 TXV 35,400 15.00 12.20 033-36 SLP98UH110XV60C 6508118 X016-036-230 TXV 35,800 14.00 11.00 033-38 6508129 X016-036-230 TXV 36,400 15.50 12.20 033-38 EL180UH045E36A 6508518 XC16-036-230 TXV 36,400 15.50 12.20 033-38 EL180UH045XE36A 6603408 X016-036-230 TXV 36,400 15.50 12.20 033-38 EL180UH070E36B 6508524 XC16-036-230 TXV 36,200 15.00 11.70 033-38 EL195UH045XE36B 6508135 X016-036-230 TXV 36,200 15.50 12.20 033-38 EL195UH070XE36B 6508142 X016-036-230 TXV 34,600 14.50 11.00 033-38 EL296UH045XE36B 6508457 X016-036-230 TXV 36,200 15.50 12.20 033-38 EL296UH045XV36B 6508160 X016-036-230 TXV 34,800 14.50 11.00 033-38 EL296UH070XE36B 6508464 X016-036-230 TXV 36,400 15.50 12.20 033-38 EL296UH070XV36B 6693722 X016-036-230 TXV 36,400 15.50 12.20 033-38 SL280UH070V36A 6508124 X016-036-230 TXV 36,400 15.50 12.20 033-38 SL280UH070XV36A 6508537 X016-036-230 TXV 36,600 15.50 12.50 033-38 SL280UH090V36B 6508165 X016-036-230 TXV 36,400 15.50 12.50 033-38 SL280UH090V48B 6508171 X016-036-230 TXV 36,600 15.50 12.50 033-38 SL280UH090XV48B 6508543 X016-036-230 TXV 36,400 15.50 12.20 033-38 SLP98UH070XV36B 6508175 X016-036-230 TXV 34,400 13.00 11.00 033-42 6508182 X016-036-230 TXV 34,800 14.50 11.00 033-42 EL195UH045XE36B 6508187 X016-036-230 TXV 34,800 14.50 11.70 033-42 EL195UH070XE36B 6508192 X016-036-230 TXV 34,600 14.50 11.00 033-42 EL296UH045XE36B 6513840 X016-036-230 TXV 34,800 15.00 11.70 033-42 EL296UH045XV36B 6508199 X016-036-230 TXV 34,800 14.50 11.00 033-42 EL296UH070XE36B 6513841 X016-036-230 TXV 35,000 15.00 11.70 033-42 EL296UH070XV36B 6693724 X016-036-230 TXV 35,200 15.00 12.00 033-42 SL280UH090V36B 6508211 X016-036-230 TXV 35,000 15.00 12.00 033-42 SL280UH090V48B 6508217 X016-036-230 TXV 35,200 15.00 12.20 033-42 SL280UH090XV48B 6508546 X016-036-230 TXV 35,000 15.00 11.70 033-42 SLP98UH070XV36B 6508222 X016-036-230 TXV 36,200 14.00 11.70 033-43 6508251 X016-036-230 TXV 36,600 15.50 12.50 033-43 CBWMV-360-090 6508577 X016-036-230 TXV 37,000 16.00 12.50 033-43 CBWMV-600-100 6508579 X016-036-230 TXV 35,000 15.00 11.70 033-43 EL180UH070E36B 6508571 X016-036-230 TXV 36,600 15.50 12.20 033-43 EL180UH070XE36B 6512856 X016-036-230 TXV 36,400 15.00 11.70 033-43 EL195UH045XE36B 6508255 X016-036-230 TXV 36,400 15.50 12.20 033-43 EL195UH070XE36B 6508262 X016-036-230 TXV 36,400 15.00 11.70 033-43 EL296UH045XE36B 6508586 X016-036-230 TXV 36,600 15.50 12.20 033-43 EL296UH045XV36B 6508228 XC16-036-230 TXV 36,400 15.00 12.00 033-43 EL296UH070XE ) Ratings AHRI Certified to AHRI Standard 210/240(with 25 ft.of connecting refrigerant lines);95°F outdoor air temperature,80°F db/67°F wb y�E r All ratings include the use of a blower time delay relay(TDR).All Lennox variable-speed furnaces and Air Handlers have time delay capabilities.Other Furnaces and Air Handlers may require an optional time delay relay(58M81)for field installation.See furnace or air handler specifications to determine if relay is need.".O/O 9/1 8 Also see Expansion Valve Kit Usage Table. e�p XC16-2 to 5 Ton Air611tl ti �P M NT AHRI SYSTEM MATCHES NOTE-For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model Expansion Coil or AHRI No. Device Capacity SEER EER Air Handler Furnace Reference XC16-036-230 TXV 36,600 15.50 12.20 033-43 EL296UH070XV36B 6508619 XC16-036-230 TXV 36,600 16.00 12.50 C33-43 EL296UH110XV48C 6508274 XC16-036-230 TXV 37,000 16.00 12.50 C33-43 SL280UH090V36B 6508233 X016-036-230 TXV 36,000 16.00 12.50 C33-43 SL280UH090V48B 6508238 XC16-036-230 TXV 36,000 16.00 12.50 C33-43 SL280UH090XV48B 6508604 X016-036-230 TXV 37,000 15.10 12.50 C33-43 SL280UH090XV60C 6508607 XC16-036-230 TXV 36,800 15.10 12.50 033-43 SL280UH110V60C 6507585 X016-036-230 TXV 36,800 15.10 12.50 033-43 SL280UH110XV60C 6508279 XC16-036-230 TXV 36,600 15.50 12.20 033-43 SLP98UH070XV36B 6508244 XC16-036-230 TXV 36,800 15.50 12.50 033-43 SLP98UH090XV36C 6508285 XC16-036-230 TXV 36,800 16.00 12.50 033-43 SLP98UH090XV48C 6508291 XC16-036-230 TXV 37,200 16.00 12.50 033-43 SLP98UH090XV60C 6508296 XC16-036-230 TXV 37,000 15.50 12.50 033-43 SLP98UH110XV60C 6508302 XC16-036-230 TXV 35,600 13.00 11.00 033-48 6508331 XC16-036-230 TXV 36,000 15.50 12.00 033-48 EL180UH070E36B 6508641 XC16-036-230 TXV 35,800 14.50 11.70 033-48 EL195UH045XE36B 6508337 X016-036-230 TXV 35,600 14.50 12.00 033-48 EL195UH070XE36B 6508343 X016-036-230 TXV 35,800 14.50 11.70 033-48 EL296UH045XE36B 6508646 X016-036-230 TXV 36,000 15.50 12.20 033-48 EL296UH045XV36B 6508307 X016-036-230 TXV 35,800 15.00 11.70 033-48 EL296UH070XE36B 6508653 X016-036-230 TXV 36,000 15.50 12.00 033-48 EL296UH070XV36B 6693723 X016-036-230 TXV 36,200 15.50 12.50 033-48 EL296UH110XV48C 6508354 X016-036-230 TXV 36,200 15.50 12.20 033-48 SL280UH090V36B 6508313 X016-036-230 TXV 36,200 15.00 12.50 033-48 SL280UH090V48B 6508320 X016-036-230 TXV 36,600 15.10 12.20 033-48 SL280UH090V60C 6508662 X016-036-230 TXV 36,200 15.50 12.50 033-48 SL280UH090XV48B 6508634 X016-036-230 TXV 36,600 15.10 12.20 033-48 SL280UH090XV60C 6508361 XC16-036-230 TXV 36,400 15.10 12.20 033-48 SL280UH110V60C 6508367 XC16-036-230 TXV 36,400 15.10 12.20 033-48 SL280UH110XV60C 6508665 XC16-036-230 TXV 36,000 15.50 12.00 033-48 SLP98UH070XV36B 6508325 XC16-036-230 TXV 36,200 15.50 12.50 033-48 SLP98UH090XV36C 6508373 XC16-036-230 TXV 36,400 15.50 12.20 033-48 SLP98UH090XV48C 6508379 X016-036-230 TXV 36,600 15.50 12.20 033-48 SLP98UH090XV60C 6508384 XC16-036-230 TXV 36,400 15.50 12.50 033-48 SLP98UH110XV60C 6508390 XC16-036-230 TXV 36,400 14.00 11.70 033-49 6508395 X016-036-230 TXV 37,000 15.50 12.50 033-49 EL296UH090XV36C 6508686 XC16-036-230 TXV 37,600 16.00 12.50 033-49 SL280UH090V60C 6508401 X016-036-230 TXV 37,600 16.00 12.50 033-49 SL280UH090XV60C 6508694 X016-036-230 TXV 37,200 15.10 12.50 033-49 SL280UH110V60C 6508408 X016-036-230 TXV 37,400 15.10 12.50 033-49 SL280UH110XV60C 6508697 X016-036-230 TXV 37,000 16.00 12.50 033-49 SLP98UH090XV36C 6508414 XC16-036-230 TXV 37,400 16.00 12.50 033-49 SLP98UHO9OXV48C 6508419 XC16-036-230 TXV 37,600 16.00 12.50 033-49 SLP98UH090XV60C 6508425 X016-036-230 TXV 37,400 16.00 12.50 033-49 SLP98UH110XV60C 6508431 XC16-036-230 TXV 36,400 16.00 12.50 033-50/600 EL296UH110XV48C 6508437 X016-036-230 TXV 34,800 13.00 11.00 CBX25UH-030 6508712 XC16-036-230 TXV 35,400 15.00 12.00 CBX25UHV-030 MEDRatings AHRI Certified to AHRI Standard 210/240(with 25 ft.of connecting refrigerant lines);95°F outdoor air temperature,80°F db/67°F wb enterin , Eel All ratings include the use of a blower time delay relay(TDR).All Lennox variable-speed furnaces and Air Handlers have time delay capabilities.Other Furnaces and Air Handlers may require an optional time delay relay(58M81)for field installation.See furnace or air handler specifications to determine if relay is needed. 10/0 9/1 8 Also see Expansion Valve Kit Usage Table. XC16-2 to 5 Ton Air Conditioner /Page 14 ASPEN BUILDING DEPARTMENT AHRI SYSTEM MATCHES NOTE- For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model Expansion Coil or AHRI No. Device Capacity SEER EER Air Handler Furnace Reference XC16-036-230 TXV 36,000 15.50 12.20 CBX25UHV-036 6970138 XC16-036-230 TXV 37,000 16.00 13.00 CBX25UHV-042 7040824 XC16-036-230 TXV 35,800 15.00 12.20 CBX27UH-036 6507591 XC16-036-230 TXV 37,000 16.00 12.50 CBX27UH-042 6507593 XC16-036-230 TXV 35,200 14.50 11.70 CBX32M-030 6507595 XC16-036-230 TXV 35,400 14.50 11.70 CBX32M-036 6507596 XC16-036-230 TXV 35,600 14.50 11.70 CBX32M-042 6507598 XC16-036-230 TXV 35,600 15.00 12.00 CBX32MV-024/030 6507601 XC16-036-230 TXV 36,000 15.50 12.00 CBX32MV-036 6507604 XC16-036-230 TXV 37,000 16.00 12.50 CBX32MV-048 6507605 XC16-036-230 TXV 35,400 15.00 11.70 CBX4OUHV-030 6508718 XC16-036-230 TXV 35,200 15.00 12.00 CBX4OUHV-036 6508721 XC16-036-230 TXV 36,600 15.50 12.20 CBX4OUHV-042 6508725 XC16-036-230 TXV 36,600 15.00 12.50 CBX4OUHV-048 6508727 XC16-036-230 TXV 35,000 13.00 11.00 CH23-41 6507610 XC16-036-230 TXV 35,600 15.00 12.00 0H23-41 EL180UH070E36B 6508733 XC16-036-230 TXV 35,600 14.50 11.70 0H23-41 EL195UH045XE36B 6507612 XC16-036-230 TXV 35,400 15.00 12.00 0H23-41 EL195UH070XE36B 6507615 XC16-036-230 TXV 35,200 14.50 11.00 0H23-41 EL296UH045XE36B 6508736 XC16-036-230 TXV 35,200 14.50 11.00 0H23-41 EL296UH070XE36B 6508739 XC16-036-230 TXV 35,400 15.50 12.00 0H23-41 EL296UH070XV36B 6508730 XC16-036-230 TXV 35,600 15.50 12.20 CH23-41 EL296UH090XV36C 6508742 XC16-036-230 TXV 35,400 15.50 12.20 0H23-41 EL296UH090XV48C 6508745 XC16-036-230 TXV 36,000 15.50 12.20 0H23-41 EL296UH090XV60C 6508748 XC16-036-230 TXV 35,600 15.50 12.50 0H23-41 EL296UH110XV48C 6507618 XC16-036-230 TXV 36,000 15.50 12.50 0H23-41 EL296UH110XV60C 6508750 XC16-036-230 TXV 35,400 15.50 12.50 0H23-41 SL280UH090V36B 6507624 XC16-036-230 TXV 35,600 15.00 12.50 CH23-41 SL280UH090V48B 6507626 XC16-036-230 TXV 36,000 15.10 12.50 0H23-41 SL280UH090V60C 6507629 XC16-036-230 TXV 35,600 15.50 12.50 0H23-41 SL280UH090XV48B 6508754 XC16-036-230 TXV 36,000 15.10 12.50 0H23-41 SL280UH090XV60C 6508756 XC16-036-230 TXV 35,800 15.10 12.20 0H23-41 SL280UH110V60C 6507633 XC16-036-230 TXV 35,800 15.10 12.20 0H23-41 SL280UH110XV60C 6508759 XC16-036-230 TXV 35,400 15.50 12.00 0H23-41 SLP98UH070XV36B 6507637 XC16-036-230 TXV 35,600 15.50 12.20 0H23-41 SLP98UH090XV36C 6507641 XC16-036-230 TXV 35,400 15.50 12.20 0H23-41 SLP98UH090XV48C 6507644 XC16-036-230 TXV 36,000 15.50 12.20 0H23-41 SLP98UH090XV60C 6507650 XC16-036-230 TXV 36,000 15.50 12.50 0H23-41 SLP98UH110XV60C 6507653 XC16-036-230 TXV 35,600 15.00 12.50 0H23-51 EL180UH070E36B 6507667 XC16-036-230 TXV 35,600 15.00 11.70 0H23-51 EL195UH045XE36B 6507657 XC16-036-230 TXV 35,600 15.00 12.20 0H23-51 EL195UH070XE36B 6507659 XC16-036-230 TXV 35,200 14.50 11.00 0H23-51 EL296UH045XE36B 6508762 XC16-036-230 TXV 35,400 14.50 11.70 0H23-51 EL296UH070XE36B 6508765 XC16-036-230 TXV 35,800 15.50 12.50 0H23-51 EL296UH110XV48C 6507664 XC16-036-230 TXV 35,400 13.00 11.00 0H23-65 6507673 XC16-036-230 TXV 36,000 15.50 12.00 0H23-65 EL180UH070E36B 6508775 XC16 036 230 TXV 36,000 15.00 11.70 CH23 65 EL195UH045XE � t�L' Ratings AHRI Certified to AHRI Standard 210/240(with 25 ft.of connecting refrigerant lines);95°F outdoor air temperature,80°F db/67°F wb y r All ratings include the use of a blower time delay relay(TDR).All Lennox variable-speed furnaces and Air Handlers have time delay capabilities.Other Furnaces and Air Handlers may require an optional time delay relay(58M81)for field installation.See furnace or air handler specifications to determine if relay is need.".O/O 9/1 8 Also see Expansion Valve Kit Usage Table. e�p XC16-2 to 5 Ton Air66itti ti �P M NT AHRI SYSTEM MATCHES NOTE-For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model Expansion Coil or AHRI No. Device Capacity SEER EER Air Handler Furnace Reference XC16-036-230 TXV 36,000 15.00 12.20 0H23-65 EL195UH070XE36B 6507678 XC16-036-230 TXV 35,600 14.50 11.70 CH23-65 EL296UH045XE36B 6508778 XC16-036-230 TXV 35,800 15.00 11.70 CH23-65 EL296UH070XE36B 6508781 XC16-036-230 TXV 36,200 15.50 12.50 CH23-65 EL296UH090XV36C 6508772 XC16-036-230 TXV 36,000 15.50 12.50 CH23-65 EL296UH090XV48C 6508784 XC16-036-230 TXV 36,600 16.00 12.50 CH23-65 EL296UH090XV60C 6508787 XC16-036-230 TXV 36,400 16.00 12.50 0H23-65 EL296UH110XV60C 6508789 XC16-036-230 TXV 36,600 15.10 12.50 0H23-65 SL280UH090V60C 6507687 XC16-036-230 TXV 36,400 15.10 12.50 0H23-65 SL280UH090XV60C 6508795 XC16-036-230 TXV 36,400 15.10 12.50 CH23-65 SL280UH110V60C 6507691 XC16-036-230 TXV 36,600 15.10 12.50 0H23-65 SL280UH110XV60C 6508792 XC16-036-230 TXV 36,200 15.50 12.50 0H23-65 SLP98UH090XV36C 6507695 XC16-036-230 TXV 36,000 15.50 12.50 0H23-65 SLP98UH090XV48C 6507699 XC16-036-230 TXV 36,600 15.50 12.50 0H23-65 SLP98UH090XV60C 6507702 XC16-036-230 TXV 36,400 15.50 12.50 0H23-65 SLP98UH110XV60C 6507706 XC16-036-230 TXV 36,200 15.00 12.00 0H33-31 EL296UH045XV36B 6507710 XC16-036-230 TXV 34,800 15.00 11.70 0H33-36 EL296UH045XV36B 6507737 XC16-036-230 TXV 34,800 15.00 11.70 CH33-36 EL296UH070XV36B 6508798 XC16-036-230 TXV 35,600 15.00 12.20 0H33-36 EL296UH090XV36C 6508801 XC16-036-230 TXV 35,400 15.50 12.20 0H33-36 EL296UH090XV48C 6508804 XC16-036-230 TXV 36,000 15.50 12.20 0H33-36 EL296UH090XV60C 6508807 XC16-036-230 TXV 35,800 15.50 12.20 CH33-36 EL296UH110XV60C 6508810 XC16-036-230 TXV 35,000 15.00 12.00 0H33-36 SL280UH090V48B 6508814 XC16-036-230 TXV 36,000 15.10 12.20 CH33-36 SL280UH090V60C 6507766 XC16-036-230 TXV 35,000 15.00 12.00 0H33-36 SL280UH090XV48B 6507750 XC16-036-230 TXV 36,000 15.10 12.20 CH33-36 SL280UH090XV60C 6508817 XC16-036-230 TXV 35,800 15.00 12.00 CH33-36 SL280UH110V60C 6507770 XC16-036-230 TXV 35,800 15.10 12.00 CH33-36 SL280UH110XV60C 6508819 XC16-036-230 TXV 34,800 15.00 11.70 CH33-36 SLP98UH070XV36B 6507754 XC16-036-230 TXV 35,600 15.00 12.20 CH33-36 SLP98UH090XV36C 6507774 XC16-036-230 TXV 35,400 15.00 12.20 CH33-36 SLP98UH090XV48C 6507777 XC16-036-230 TXV 36,000 15.50 12.20 CH33-36 SLP98UH090XV60C 6507783 XC16-036-230 TXV 35,800 15.50 12.20 CH33-36 SLP98UH110XV60C 6507786 XC16-036-230 TXV 35,400 15.00 11.70 CH33-36A EL180UH045E36A 6508823 XC16-036-230 TXV 34,800 14.50 11.70 CH33-36A SL280UH070V36A 6604856 XC16-036-230 TXV 34,800 14.50 11.70 CH33-36A SL280UH070XV36A 6604858 XC16-036-230 TXV 34,400 13.00 11.00 CH33-36B 6507726 XC16-036-230 TXV 35,400 15.00 11.70 0H33-36B EL180UH070XE36B 6508826 XC16-036-230 TXV 34,600 14.50 11.00 0H33-36B EL195UH045XE36B 6507730 XC16-036-230 TXV 34,800 14.50 11.70 0H33-36B EL195UH070XE36B 6507735 XC16-036-230 TXV 35,200 14.50 11.00 0H33-36B EL296UH045XE36B 6508828 XC16-036-230 TXV 35,200 15.00 11.00 0H33-36B EL296UH070XE36B 6508831 XC16-036-230 TXV 35,200 15.00 12.00 0H33-36B SL280UH070V36A 6604855 XC16-036-230 TXV 35,200 15.00 12.00 0H33-36B SL280UH070XV36A 6604857 XC16-036-230 TXV 35,000 13.00 11.00 0H33-360 6507758 XC16-036-230 TXV 35,600 15.50 12.20 CH33-36C EL296UH110XV48C 6507762 XC16-036-230 TXV 35,400 13.00 11.00 CH33-42 � ���� Ratings AHRI Certified to AHRI Standard 210/240(with 25 ft.of connecting refrigerant lines);95°F outdoor air temperature,80°F db/67°F wb enterin , ,. All ratings include the use of a blower time delay relay(TDR).All Lennox variable-speed furnaces and Air Handlers have time delay capabilities.Other Furnaces and Air Handlers may require an optional time delay relay(58M81)for field installation.See furnace or air handler specifications to determine if relay is needed. 10/0 9/1 8 Also see Expansion Valve Kit Usage Table. XC16-2 to 5 Ton Air Conditioner /Page 16 ASPEN BUILDING DEPARTMENT AHRI SYSTEM MATCHES NOTE- For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model Expansion Coil or AHRI No. Device Capacity SEER EER Air Handler Furnace Reference XC16-036-230 TXV 36,000 15.50 12.00 0H33-42 EL180UH070E36B 6508837 XC16-036-230 TXV 35,600 14.50 11.70 CH33-42 EL195UH045XE36B 6507793 XC16-036-230 TXV 35,600 14.50 11.70 0H33-42 EL195UH070XE36B 6507798 XC16-036-230 TXV 35,600 14.50 11.70 CH33-42 EL296UH045XE36B 6508839 XC16-036-230 TXV 35,800 15.00 11.70 0H33-42 EL296UH045XV36B 6507802 XC16-036-230 TXV 35,600 15.00 11.70 CH33-42 EL296UH070XE36B 6508842 XC16-036-230 TXV 35,800 15.00 12.00 0H33-42 EL296UH070XV36B 6508845 XC16-036-230 TXV 36,000 15.50 12.20 0H33-42 SL280UH090V36B 6507810 XC16-036-230 TXV 35,800 15.00 12.20 0H33-42 SL280UH090V48B 6507814 XC16-036-230 TXV 36,000 15.00 12.20 0H33-42 SL280UH090XV48B 6508834 XC16-036-230 TXV 35,800 15.00 12.00 0H33-42 SLP98UH070XV36B 6507819 XC16-036-230 TXV 37,200 16.00 12.50 0H33-43 EL180UH070E36B 6508853 XC16-036-230 TXV 37,000 15.00 12.00 0H33-43 EL195UH045XE36B 6507826 XC16-036-230 TXV 37,000 15.00 12.20 0H33-43 EL195UH070XE36B 6507832 XC16-036-230 TXV 37,000 15.00 12.00 CH33-43 EL296UH045XE36B 6508856 XC16-036-230 TXV 37,000 15.50 12.20 0H33-43 EL296UH045XV36B 6507835 XC16-036-230 TXV 37,000 15.50 12.20 0H33-43 EL296UH070XE36B 6508859 XC16-036-230 TXV 37,000 15.50 12.20 0H33-43 EL296UH070XV36B 6508862 XC16-036-230 TXV 36,800 15.50 12.50 0H33-43 EL296UH090XV36C 6508864 XC16-036-230 TXV 36,600 16.00 12.50 0H33-43 EL296UH090XV48C 6508868 XC16-036-230 TXV 37,200 16.00 12.50 0H33-43 EL296UH090XV60C 6508870 XC16-036-230 TXV 37,200 16.00 12.50 0H33-43 EL296UH110XV60C 6508873 XC16-036-230 TXV 37,600 16.00 12.50 0H33-43 SL280UH090V36B 6507842 XC16-036-230 TXV 36,000 16.00 12.50 0H33-43 SL280UH090V48B 6507846 XC16-036-230 TXV 37,200 15.10 12.50 0H33-43 SL280UH090V60C 6507862 XC16-036-230 TXV 36,000 16.00 12.50 0H33-43 SL280UH090XV48B 6508878 XC16-036-230 TXV 37,200 16.00 12.50 0H33-43 SL280UH090XV60C 6508848 XC16-036-230 TXV 37,000 15.10 12.50 CH33-43 SL280UH110V60C 6507866 XC16-036-230 TXV 37,000 15.10 12.50 0H33-43 SL280UH110XV60C 6508851 XC16-036-230 TXV 37,000 15.50 12.20 0H33-43 SLP98UH070XV36B 6507850 XC16-036-230 TXV 36,800 15.50 12.50 0H33-43 SLP98UH090XV36C 6507869 XC16-036-230 TXV 37,000 16.00 12.50 0H33-43 SLP98UH090XV48C 6507873 XC16-036-230 TXV 37,200 16.00 12.50 0H33-43 SLP98UH090XV60C 6507876 XC16-036-230 TXV 37,200 16.00 12.50 0H33-43 SLP98UH110XV60C 6507879 XC16-036-230 TXV 36,800 14.00 11.70 0H33-43B 6507823 XC16-036-230 TXV 36,200 14.00 11.70 0H33-430 6507854 XC16-036-230 TXV 36,800 16.00 12.50 0H33-430 EL296UH110XV48C 6507857 XC16-036-230 TXV 36,000 14.00 11.00 0H33-44/48 6507884 XC16-036-230 TXV 36,400 15.50 12.20 0H33-44/48 EL180UH070E36B 6508883 XC16-036-230 TXV 36,200 15.00 11.70 0H33-44/48 EL180UH070XE36B 6508889 XC16-036-230 TXV 36,200 14.50 11.70 0H33-44/48 EL195UH045XE36B 6507888 XC16-036-230 TXV 36,200 15.00 11.70 0H33-44/48 EL195UH070XE36B 6507892 XC16-036-230 TXV 36,200 15.00 11.70 0H33-44/48 EL296UH045XE36B 6508886 XC16-036-230 TXV 36,200 15.00 12.00 0H33-44/48 EL296UH045XV36B 6507896 XC16-036-230 TXV 36,200 15.50 12.00 0H33-44/48 EL296UH070XV36B 6508892 XC16-036-230 TXV 36,800 15.50 12.50 0H33-44/48 SL280UH090V36B 6507904 XC16 036 230 TXV 36,400 15.00 12.20 0H33 44/48 SL280UH090V4 t�L' Ratings AHRI Certified to AHRI Standard 210/240(with 25 ft.of connecting refrigerant lines);95°F outdoor air temperature,80°F db/67°F wb, y r All ratings include the use of a blower time delay relay(TDR).All Lennox variable-speed furnaces and Air Handlers have time delay capabilities.Other Furnaces and Air Handlers may require an optional time delay relay(58M81)for field installation.See furnace or air handler specifications to determine if relay is need.".O/O 9/1 8 Also see Expansion Valve Kit Usage Table. XC16-2 to 5 Ton Air 661111 i �Pe�p M�NT AHRI SYSTEM MATCHES NOTE-For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model Expansion Coil or AHRI No. Device Capacity SEER EER Air Handler Furnace Reference XC16-036-230 TXV 36,400 15.50 12.20 0H33-44/48 SL280UH090XV48B 6508879 XC16-036-230 TXV 36,400 15.50 12.20 CH33-44/48 SLP98UH070XV36B 6507914 XC16-036-230 TXV 36,000 14.00 11.00 CH33-48 6507918 XC16-036-230 TXV 36,600 15.50 12.50 CH33-48 EL296UH090XV36C 6508901 XC16-036-230 TXV 36,400 15.50 12.50 CH33-48 EL296UH090XV48C 6508903 XC16-036-230 TXV 37,000 16.00 12.50 CH33-48 EL296UH090XV60C 6508907 XC16-036-230 TXV 36,800 16.00 12.50 0H33-48 EL296UH110XV60C 6508909 XC16-036-230 TXV 37,000 15.10 12.50 0H33-48 SL280UH090V60C 6507926 XC16-036-230 TXV 37,000 15.10 12.50 0H33-48 SL280UH090XV60C 6508898 XC16-036-230 TXV 36,800 15.10 12.20 CH33-48 SL280UH110V60C 6507930 XC16-036-230 TXV 36,800 15.10 12.50 0H33-48 SL280UH110XV60C 6508895 XC16-036-230 TXV 36,600 15.50 12.50 0H33-48 SLP98UH090XV36C 6507934 XC16-036-230 TXV 36,800 16.00 12.50 0H33-48 SLP98UH090XV48C 6507938 XC16-036-230 TXV 37,000 15.50 12.50 0H33-48 SLP98UH090XV60C 6507942 XC16-036-230 TXV 36,800 15.50 12.50 0H33-48 SLP98UH110XV60C 6507945 XC16-036-230 TXV 36,600 16.00 12.50 0H33-48C EL296UH110XV48C 6507922 XC16-036-230 TXV 37,000 16.00 12.50 0H33-50/60C EL296UH110XV48C 6507949 XC16-036-230 TXV 34,400 13.00 11.00 CH35-30A 7165479 XC16-036-230 TXV 34,600 13.00 11.00 0H35-30B 7165480 XC16-036-230 TXV 36,000 15.10 12.00 0H35-30B EL296UH045XV36B 7165647 XC16-036-230 TXV 35,000 14.50 11.50 0H35-36A EL180UH045E36A 7165481 XC16-036-230 TXV 34,800 14.50 11.50 CH35-36A SL280UH070V36A 7165594 XC16-036-230 TXV 35,000 14.50 11.50 0H35-36A SL280UH070XV36A 7165482 XC16-036-230 TXV 34,600 13.00 11.00 CH35-36B 7165483 XC16-036-230 TXV 35,200 15.10 11.50 0H35-36B EL180UH070XE36B 7165484 XC16-036-230 TXV 34,800 14.50 11.50 CH35-36B EL195UH045XE36B 7165485 XC16-036-230 TXV 34,800 14.50 11.50 CH35-36B EL195UH070XE36B 7165486 XC16-036-230 TXV 34,800 14.50 11.00 CH35-36B EL296UH045XE36B 7165488 XC16-036-230 TXV 35,000 15.10 11.50 CH35-36B EL296UH045XV36B 7165487 XC16-036-230 TXV 34,800 14.50 11.50 CH35-36B EL296UH070XE36B 7165489 XC16-036-230 TXV 35,000 15.10 11.50 0H35-36B EL296UH070XV36B 7165490 XC16-036-230 TXV 35,400 15.10 12.00 CH35-36B SL280UH090V36B 7165595 XC16-036-230 TXV 35,200 15.00 12.20 CH35-36B SL280UH090V48B 7165648 XC16-036-230 TXV 35,200 15.10 12.20 CH35-36B SL280UH090XV48B 7165491 XC16-036-230 TXV 35,000 15.00 11.50 CH35-36B SLP98UH070XV36B 7165596 XC16-036-230 TXV 35,000 13.00 11.00 CH35-36C 7165492 XC16-036-230 TXV 35,600 15.10 12.20 CH35-36C EL296UH090XV36C 7165493 XC16-036-230 TXV 35,400 15.50 12.20 CH35-36C EL296UH090XV48C 7165494 XC16-036-230 TXV 36,000 15.50 12.20 CH35-36C EL296UH090XV60C 7165495 XC16-036-230 TXV 35,600 15.50 12.20 0H35-36C EL296UH110XV48C 7165496 XC16-036-230 TXV 36,000 15.50 12.20 0H35-36C EL296UH110XV60C 7165497 XC16-036-230 TXV 36,000 15.10 12.20 0H35-360 SL280UH090V60C 7165597 XC16-036-230 TXV 36,000 15.10 12.20 0H35-36C SL280UH090XV60C 7165498 XC16-036-230 TXV 35,800 15.10 12.20 0H35-360 SL280UH110V60C 7165499 XC16-036-230 TXV 35,800 15.10 12.20 0H35-360 SL280UH110XV60C 7165500 XC16-036-230 TXV 35,600 15.10 12.20 CH35-360 SLP98UH090XV36C 7165598 XC16-036-230 TXV 35,400 15.10 12.20 CH35-36C SLP98UH090XV48C in ���D Ratings AHRI Certified to AHRI Standard 210/240(with 25 ft.of connecting refrigerant lines);95°F outdoor air temperature,80°F db/67°F wb enteringiRECE All ratings include the use of a blower time delay relay(TDR).All Lennox variable-speed furnaces and Air Handlers have time delay capabilities.Other Furnaces and Air Handlers may require an optional time delay relay(58M81)for field installation.See furnace or air handler specifications to determine if relay is needed. 10/0 9/1 8 Also see Expansion Valve Kit Usage Table. XC16-2 to 5 Ton Air Conditioner /Page 18 ASPEN BUILDING DEPARTMENT AHRI SYSTEM MATCHES NOTE- For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model Expansion Coil or AHRI No. Device Capacity SEER EER Air Handler Furnace Reference XC16-036-230 TXV 36,000 15.50 12.20 0H35-360 SLP98UH090XV60C 7165600 XC16-036-230 TXV 36,000 15.50 12.20 0H35-360 SLP98UH110XV60C 7165601 XC16-036-230 TXV 36,000 14.25 11.50 0H35-42B 7165501 XC16-036-230 TXV 36,000 16.00 12.50 0H35-42B EL180UH070E36B 7165502 XC16-036-230 TXV 36,000 15.10 12.00 0H35-42B EL195UH045XE36B 7165503 XC16-036-230 TXV 36,000 15.10 12.20 CH35-42B EL195UH070XE36B 7165504 XC16-036-230 TXV 36,000 15.10 12.00 0H35-42B EL296UH045XE36B 7165506 XC16-036-230 TXV 36,000 15.50 12.20 0H35-42B EL296UH045XV36B 7165505 XC16-036-230 TXV 36,000 15.50 12.20 0H35-42B EL296UH070XE36B 7165507 XC16-036-230 TXV 36,000 15.50 12.20 0H35-42B EL296UH070XV36B 7165508 XC16-036-230 TXV 36,000 16.00 12.50 0H35-42B SL280UH090V36B 7165602 XC16-036-230 TXV 36,000 15.50 12.50 0H35-42B SL280UH090V48B 7165603 XC16-036-230 TXV 36,000 15.50 12.50 0H35-42B SL280UH090XV48B 7165509 XC16-036-230 TXV 36,000 15.50 12.20 0H35-42B SLP98UH070XV36B 7165604 XC16-036-230 TXV 36,000 14.25 11.50 CH35-420 7165510 XC16-036-230 TXV 36,000 15.50 12.50 0H35-420 EL296UH090XV36C 7165511 XC16-036-230 TXV 36,000 16.00 12.50 0H35-420 EL296UH090XV48C 7165512 XC16-036-230 TXV 36,000 16.00 12.50 0H35-420 EL296UH090XV60C 7165513 XC16-036-230 TXV 36,000 16.00 12.50 0H35-420 EL296UH110XV48C 7165514 XC16-036-230 TXV 36,000 16.00 12.50 0H35-420 EL296UH110XV60C 7165515 XC16-036-230 TXV 36,000 16.00 12.50 0H35-420 SL280UH090V60C 7165605 XC16-036-230 TXV 36,000 16.00 12.50 0H35-420 SL280UH090XV60C 7165516 XC16-036-230 TXV 36,000 15.10 12.50 0H35-420 SL280UH110V60C 7165517 XC16-036-230 TXV 36,000 15.10 12.50 0H35-420 SL280UH110XV60C 7165518 XC16-036-230 TXV 36,000 16.00 12.50 0H35-420 SLP98UH090XV36C 7165606 XC16-036-230 TXV 36,000 16.00 12.50 0H35-420 SLP98UH090XV48C 7165607 XC16-036-230 TXV 36,000 16.00 12.50 0H35-420 SLP98UH090XV60C 7165608 XC16-036-230 TXV 36,000 16.00 12.50 CH35-42C SLP98UH110XV60C 7165609 XC16-036-230 TXV 36,000 14.00 11.50 0H35-48B 7165519 XC16-036-230 TXV 36,000 15.50 12.20 0H35-48B EL180UH070E36B 7165520 XC16-036-230 TXV 36,000 15.00 11.50 0H35-48B EL195UH045XE36B 7165521 XC16-036-230 TXV 36,000 15.00 12.00 0H35-48B EL195UH070XE36B 7165522 XC16-036-230 TXV 36,000 15.10 11.50 0H35-48B EL296UH045XE36B 7165524 XC16-036-230 TXV 36,000 15.50 12.00 0H35-48B EL296UH045XV36B 7165523 XC16-036-230 TXV 36,000 15.10 12.00 0H35-48B EL296UH070XE36B 7165525 XC16-036-230 TXV 36,000 15.50 12.20 0H35-48B EL296UH070XV36B 7165526 XC16-036-230 TXV 36,000 15.50 12.50 0H35-48B SL280UH090V36B 7165610 XC16-036-230 TXV 36,000 15.10 12.50 0H35-48B SL280UH090V48B 7165611 XC16-036-230 TXV 36,000 15.50 12.50 0H35-48B SL280UH090XV48B 7165527 XC16-036-230 TXV 36,000 15.50 12.20 0H35-48B SLP98UH070XV36B 7165612 XC16-036-230 TXV 36,000 14.00 11.50 0H35-480 7165528 XC16-036-230 TXV 36,000 15.50 12.50 0H35-480 EL296UH090XV36C 7165529 XC16-036-230 TXV 36,000 16.00 12.50 0H35-480 EL296UH090XV48C 7165530 XC16-036-230 TXV 36,000 16.00 12.50 0H35-480 EL296UH090XV60C 7165531 XC16-036-230 TXV 36,000 16.00 12.50 0H35-480 EL296UH110XV48C 7165532 XC16-036-230 TXV 36,000 16.00 12.50 0H35-480 EL296UH110XV60C 7165533 XC16-036-230 TXV 36,000 15.10 12.50 0H35-480 SL280UH090V6 D Ratings AHRI Certified to AHRI Standard 210/240(with 25 ft.of connecting refrigerant lines);95°F outdoor air temperature,80°F db/67°F wb, y r�� �I G All ratings include the use of a blower time delay relay(TDR).All Lennox variable-speed furnaces and Air Handlers have time delay capabilities.Other Furnaces and Air Handlers may require an optional time delay relay(58M81)for field installation.See furnace or air handler specifications to determine if relay is need/.0/0 9/1 8 Also see Expansion Valve Kit Usage Table. XC16-2 to 5 Ton Air61 �{� ,1 g .1NT AHRI SYSTEM MATCHES NOTE-For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model Expansion Coil or AHRI No. Device Capacity SEER EER Air Handler Furnace Reference XC16-036-230 TXV 36,000 16.00 12.50 0H35-48C SL280UH090XV60C 7165534 XC16-036-230 TXV 36,000 15.10 12.50 CH35-48C SL280UH110V60C 7165535 XC16-036-230 TXV 36,000 15.10 12.50 CH35-48C SL280UH110XV60C 7165536 XC16-036-230 TXV 36,000 15.50 12.50 CH35-48C SLP98UH090XV36C 7165580 XC16-036-230 TXV 36,000 16.00 12.50 CH35-48C SLP98UH090XV48C 7165581 XC16-036-230 TXV 36,000 16.00 12.50 CH35-48C SLP98UH090XV60C 7165582 XC16-036-230 TXV 36,000 16.00 12.50 0H35-480 SLP98UH110XV60C 7165583 XC16-036-230 TXV 36,000 14.25 11.50 0H35-510 7165537 XC16-036-230 TXV 36,000 16.00 12.50 0H35-51C EL296UH090XV48C 7165538 XC16-036-230 TXV 35,000 13.00 11.00 CR33-30/36 6507958 XC16-036-230 TXV 35,600 15.00 11.70 0R33-30/36 EL180DF070E36B 6508939 XC16-036-230 TXV 35,200 14.50 11.00 0R33-30/36 EL195DF045XE36B 6507961 XC16-036-230 TXV 35,400 15.50 12.00 0R33-30/36 EL296DF045V36B 6507969 XC16-036-230 TXV 35,200 14.50 11.00 0R33-30/36 EL296DF045XE36B 6508936 XC16-036-230 TXV 35,600 15.00 12.00 CR33-30/36 EL296DF070V48B 6507973 XC16-036-230 TXV 35,600 15.00 12.00 0R33-30/36 EL296DF090XV60C 6508933 XC16-036-230 TXV 35,600 15.00 12.00 0R33-30/36 EL296DF110XV60C 6508930 XC16-036-230 TXV 35,400 15.00 11.70 CR33-30/36 SL280DF070V36A 6507953 XC16-036-230 TXV 35,200 15.00 11.70 0R33-30/36 SL280DF070XV36A48B 6508927 XC16-036-230 TXV 35,600 15.00 12.00 0R33-30/36 SL280DF090V48B 6507976 XC16-036-230 TXV 35,600 15.00 12.00 0R33-30/36 SL280DF090V48B 6507980 XC16-036-230 TXV 36,000 15.10 12.20 CR33-30/36 SL280DF090V60C 6507984 XC16-036-230 TXV 35,600 15.10 12.20 0R33-30/36 SL280DF110V60C 6507987 XC16-036-230 TXV 35,200 15.00 12.00 CR33-30/36 SLP98DF070XV36B 6508925 XC16-036-230 TXV 35,400 15.00 12.00 0R33-30/36 SLP98DF090XV36C 6508922 XC16-036-230 TXV 35,400 15.00 12.20 CR33-30/36 SLP98DF090XV48C 6508919 XC16-036-230 TXV 35,800 15.00 12.00 CR33-30/36 SLP98DF090XV60C 6508916 XC16-036-230 TXV 35,800 15.50 12.20 CR33-30/36 SLP98DF110XV60C 6508912 XC16-036-230 TXV 35,400 13.00 11.00 CR33-48 6508002 XC16-036-230 TXV 36,200 15.00 12.00 CR33-48 EL180DF070E36B 6508957 XC16-036-230 TXV 36,000 15.00 11.70 CR33-48 EL195DF045XE36B 6508005 XC16-036-230 TXV 36,000 15.00 12.20 CR33-48 EL195DF070XE48B 6508008 XC16-036-230 TXV 35,800 15.50 12.00 CR33-48 EL296DF045V36B 6507991 XC16-036-230 TXV 35,800 14.50 11.70 CR33-48 EL296DF045XE36B 6508960 XC16-036-230 TXV 36,000 15.00 12.00 CR33-48 EL296DF070V48B 6507993 XC16-036-230 TXV 35,800 14.50 12.20 CR33-48 EL296DF070XE48B 6508962 XC16-036-230 TXV 36,200 15.50 12.20 CR33-48 EL296DF090XV60C 6508964 XC16-036-230 TXV 36,200 15.50 12.20 0R33-48 EL296DF110XV60C 6508966 XC16-036-230 TXV 36,200 15.50 12.20 0R33-48 SL280DF090V48B 6507996 XC16-036-230 TXV 36,200 15.50 12.20 0R33-48 SL280DF090V48B 6507999 XC16-036-230 TXV 36,600 15.10 12.50 CR33-48 SL280DF090V60C 6508013 XC16-036-230 TXV 36,200 15.10 12.50 0R33-48 SL280DF110V60C 6508016 XC16-036-230 TXV 35,800 15.50 12.20 0R33-48 SLP98DF070XV36B 6508953 XC16-036-230 TXV 36,000 15.50 12.20 0R33-48 SLP98DF090XV36C 6508951 XC16-036-230 TXV 36,000 15.50 12.20 0R33-48 SLP98DF090XV48C 6508949 XC16-036-230 TXV 36,200 15.50 12.20 CR33-48 SLP98DF090XV60C 6508945 XC16-036-230 TXV 36,200 15.50 12.20 CR33-48 SLP98DF110XV60C Ratings AHRI Certified to AHRI Standard 210/240(with 25 ft.of connecting refrigerant lines);95°F outdoor air temperature,80°F db/67°F wb entering _ ._� ;_ IVE All ratings include the use of a blower time delay relay(TDR).All Lennox variable-speed furnaces and Air Handlers have time delay capabilities.Other Furnaces and Air Handlers may require an optional time delay relay(58M81)for field installation.See furnace or air handler specifications to determine if relay is needed. 10/0 9/1 8 Also see Expansion Valve Kit Usage Table. XC16-2 to 5 Ton Air Conditioner /Page 20 ASPEN BUILDING DEPARTMENT AHRI SYSTEM MATCHES NOTE- For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model Expansion Coil or AHRI No. Device Capacity SEER EER Air Handler Furnace Reference XC16-036-230 TXV 34,400 13.00 11.00 0X34-36 6508024 XC16-036-230 TXV 34,800 15.00 12.00 0X34-36 CBWMV-360-090 6508442 XC16-036-230 TXV 35,000 14.50 11.70 0X34-36 EL180UH045E36A 6508450 XC16-036-230 TXV 35,000 15.00 11.70 0X34-36 EL180UH070E36B 6508454 XC16-036-230 TXV 34,800 14.50 11.00 0X34-36 EL195UH045XE36B 6508031 XC16-036-230 TXV 34,800 14.50 11.70 CX34-36 EL195UH070XE36B 6508036 XC16-036-230 TXV 35,000 15.00 12.00 0X34-36 EL195UH090XE48C 7176679 XC16-036-230 TXV 34,600 14.50 11.00 0X34-36 EL296UH045XE36B 6508460 XC16-036-230 TXV 34,800 15.00 11.70 0X34-36 EL296UH045XV36B 6508054 XC16-036-230 TXV 34,800 14.50 11.00 0X34-36 EL296UH070XE36B 6508467 XC16-036-230 TXV 35,000 15.00 11.70 0X34-36 EL296UH070XV36B 6960775 XC16-036-230 TXV 35,000 15.00 12.00 0X34-36 EL296UH090XV36C 6508504 XC16-036-230 TXV 34,800 15.00 12.00 0X34-36 EL296UH090XV48C 6508473 XC16-036-230 TXV 35,000 15.00 12.20 0X34-36 EL296UH110XV48C 6508060 XC16-036-230 TXV 35,400 15.00 12.20 CX34-36 EL296UH110XV60C 6508506 XC16-036-230 TXV 35,000 15.00 11.70 0X34-36 SL280UH070V36A 6508018 XC16-036-230 TXV 35,000 15.00 11.70 0X34-36 SL280UH070XV36A 6508479 XC16-036-230 TXV 35,200 15.00 12.00 0X34-36 SL280UH090V36B 6508066 XC16-036-230 TXV 35,000 15.00 12.00 0X34-36 SL280UH090V48B 6508073 XC16-036-230 TXV 35,400 15.00 12.00 0X34-36 SL280UH090V60C 6508079 XC16-036-230 TXV 35,200 15.00 12.20 0X34-36 SL280UH090XV48B 6508485 XC16-036-230 TXV 35,400 15.10 12.00 0X34-36 SL280UH090XV60C 6508492 XC16-036-230 TXV 35,200 15.00 12.00 0X34-36 SL280UH110V60C 6508085 XC16-036-230 TXV 35,400 15.00 12.00 0X34-36 SL280UH110XV60C 6508498 XC16-036-230 TXV 35,000 15.00 11.70 0X34-36 SLP98UH070XV36B 6508091 XC16-036-230 TXV 35,000 15.00 12.00 0X34-36 SLP98UH090XV36C 6508097 XC16-036-230 TXV 35,200 15.00 12.00 0X34-36 SLP98UH090XV48C 6508104 XC16-036-230 TXV 35,600 15.00 12.00 CX34-36 SLP98UH090XV60C 6508109 XC16-036-230 TXV 35,400 15.00 12.20 0X34-36 SLP98UH110XV60C 6508115 XC16-036-230 TXV 35,800 14.00 11.00 0X34-38 6508126 XC16-036-230 TXV 36,400 15.50 12.20 0X34-38 EL180UH045XE36A 6508515 XC16-036-230 TXV 36,400 15.50 12.20 0X34-38 EL180UH070XE36B 6508521 XC16-036-230 TXV 36,200 15.00 11.70 0X34-38 EL195UH045XE36B 6508132 XC16-036-230 TXV 36,200 15.50 12.20 0X34-38 EL195UH070XE36B 6508139 XC16-036-230 TXV 36,000 15.00 11.70 0X34-38 EL296UH045XE36B 6508527 XC16-036-230 TXV 36,200 15.50 12.20 CX34-38 EL296UH045XV36B 6508157 XC16-036-230 TXV 36,200 15.00 12.00 0X34-38 EL296UH070XE36B 6508532 XC16-036-230 TXV 36,400 15.50 12.20 0X34-38 EL296UH070XV36B 6508512 XC16-036-230 TXV 36,400 15.50 12.20 0X34-38 SL280UH070V36A 6508121 XC16-036-230 TXV 36,400 15.50 12.20 0X34-38 SL280UH070XV36A 6508535 XC16-036-230 TXV 36,600 15.50 12.50 0X34-38 SL280UH090V36B 6508162 XC16-036-230 TXV 36,400 15.50 12.50 0X34-38 SL280UH090V48B 6508168 XC16-036-230 TXV 36,600 15.50 12.50 0X34-38 SL280UH090XV48B 6508540 XC16-036-230 TXV 36,400 15.50 12.20 0X34-38 SLP98UH070XV36B 6508174 XC16-036-230 TXV 34,400 13.00 11.00 0X34-42 6508178 XC16-036-230 TXV 35,000 15.00 11.70 0X34-42 EL180UH070E36B 6508569 XC16 036 230 TXV 34,800 14.50 11.00 CX34 42 EL195UH045XE � t L' Ratings AHRI Certified to AHRI Standard 210/240(with 25 ft.of connecting refrigerant lines);95°F outdoor air temperature,80°F db/67°F wb y r All ratings include the use of a blower time delay relay(TDR).All Lennox variable-speed furnaces and Air Handlers have time delay capabilities.Other Furnaces and Air Handlers may require an optional time delay relay(58M81)for field installation.See furnace or air handler specifications to determine if relay is need.".O/O 9/1 8 Also see Expansion Valve Kit Usage Table. e�p XC16-2 to 5 Ton Air66itti ti �P M�NT AHRI SYSTEM MATCHES NOTE-For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model Expansion Coil or AHRI No. Device Capacity SEER EER Air Handler Furnace Reference XC16-036-230 TXV 34,800 14.50 11.70 0X34-42 EL195UH070XE36B 6508189 XC16-036-230 TXV 34,600 14.50 11.00 CX34-42 EL296UH045XE36B 6508555 XC16-036-230 TXV 34,800 15.00 11.70 CX34-42 EL296UH045XV36B 6508195 XC16-036-230 TXV 34,800 14.50 11.00 CX34-42 EL296UH070XE36B 6508561 XC16-036-230 TXV 35,000 15.00 11.70 CX34-42 EL296UH070XV36B 6508564 XC16-036-230 TXV 35,200 15.00 12.00 CX34-42 SL280UH090V36B 6508208 XC16-036-230 TXV 35,000 15.00 12.00 0X34-42 SL280UH090V48B 6508214 XC16-036-230 TXV 35,200 15.00 12.20 0X34-42 SL280UH090XV48B 6508549 XC16-036-230 TXV 35,000 15.00 11.70 0X34-42 SLP98UH070XV36B 6508219 XC16-036-230 TXV 36,200 14.00 11.70 CX34-43 6508248 XC16-036-230 TXV 36,600 15.50 12.50 0X34-43 CBWMV-360-090 6508574 XC16-036-230 TXV 37,000 16.00 12.50 0X34-43 CBWMV-600-100 6508582 XC16-036-230 TXV 36,600 15.50 12.20 0X34-43 EL180UH070E36B 6508598 XC16-036-230 TXV 36,400 15.00 11.70 0X34-43 EL195UH045XE36B 6508253 XC16-036-230 TXV 36,400 15.50 12.20 0X34-43 EL195UH070XE36B 6508259 XC16-036-230 TXV 36,400 15.00 11.70 0X34-43 EL296UH045XE36B 6508588 XC16-036-230 TXV 36,600 15.50 12.20 0X34-43 EL296UH045XV36B 6508225 XC16-036-230 TXV 36,400 15.00 12.00 CX34-43 EL296UH070XE36B 6508595 XC16-036-230 TXV 36,600 15.50 12.20 0X34-43 EL296UH070XV36B 6508617 XC16-036-230 TXV 36,600 15.50 12.50 0X34-43 EL296UH090XV36C 6508621 XC16-036-230 TXV 36,400 15.50 12.50 0X34-43 EL296UH090XV48C 6508626 XC16-036-230 TXV 37,200 16.00 12.50 CX34-43 EL296UH090XV60C 6508629 XC16-036-230 TXV 36,600 16.00 12.50 0X34-43 EL296UH110XV48C 6508271 XC16-036-230 TXV 37,000 16.00 12.50 CX34-43 EL296UH110XV60C 6508631 XC16-036-230 TXV 37,000 16.00 12.50 0X34-43 SL280UH090V36B 6508230 XC16-036-230 TXV 36,000 16.00 12.50 CX34-43 SL280UH090V48B 6508236 XC16-036-230 TXV 36,800 16.00 12.50 CX34-43 SL280UH090V60C 6507584 XC16-036-230 TXV 36,000 16.00 12.50 CX34-43 SL280UH090XV48B 6508601 XC16-036-230 TXV 37,000 15.10 12.50 CX34-43 SL280UH090XV60C 6508610 XC16-036-230 TXV 36,800 15.10 12.50 CX34-43 SL280UH110V60C 6508276 XC16-036-230 TXV 37,000 15.10 12.50 CX34-43 SL280UH110XV60C 6508612 XC16-036-230 TXV 36,600 15.50 12.20 CX34-43 SLP98UH070XV36B 6508241 XC16-036-230 TXV 36,800 15.50 12.50 CX34-43 SLP98UH090XV36C 6508282 XC16-036-230 TXV 36,800 16.00 12.50 CX34-43 SLP98UH090XV48C 6508288 XC16-036-230 TXV 37,200 16.00 12.50 CX34-43 SLP98UH090XV60C 6508293 XC16-036-230 TXV 37,000 15.50 12.50 CX34-43 SLP98UH110XV60C 6508299 XC16-036-230 TXV 35,600 13.00 11.00 CX34-44/48 6508328 XC16-036-230 TXV 35,800 14.50 11.70 0X34-44/48 EL180UH045XE36A 6508649 XC16-036-230 TXV 36,000 15.50 12.00 0X34-44/48 EL180UH070E36B 6508645 XC16-036-230 TXV 35,800 14.50 11.70 0X34-44/48 EL195UH045XE36B 6508334 XC16-036-230 TXV 35,600 14.50 12.00 0X34-44/48 EL195UH070XE36B 6508340 XC16-036-230 TXV 36,000 15.50 12.20 0X34-44/48 EL296UH045XV36B 6508305 XC16-036-230 TXV 35,800 15.00 11.70 0X34-44/48 EL296UH070XE36B 6508656 XC16-036-230 TXV 36,000 15.50 12.00 0X34-44/48 EL296UH070XV36B 6508671 XC16-036-230 TXV 36,200 15.50 12.50 0X34-44/48 EL296UH090XV36C 6508674 XC16-036-230 TXV 36,000 15.50 12.50 CX34-44/48 EL296UH090XV48C 6508677 XC16-036-230 TXV 36,600 15.50 12.20 CX34-44/48 EL296UH090XV60C ii.•. Ratings AHRI Certified to AHRI Standard 210/240(with 25 ft.of connecting refrigerant lines);95°F outdoor air temperature,80°F db/67°F wb entering '•• . !m �VE All ratings include the use of a blower time delay relay(TDR).All Lennox variable-speed furnaces and Air Handlers have time delay capabilities.Other Furnaces and Air Handlers may require an optional time delay relay(58M81)for field installation.See furnace or air handler specifications to determine if relay is needed. 10/0 9/1 8 Also see Expansion Valve Kit Usage Table. XC16-2 to 5 Ton Air Conditioner /Page 22 ASPEN BUILDING DEPARTMENT AHRI SYSTEM MATCHES NOTE- For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model Expansion Coil or AHRI No. Device Capacity SEER EER Air Handler Furnace Reference XC16-036-230 TXV 36,200 15.50 12.50 0X34-44/48 EL296UH110XV48C 6508351 X016-036-230 TXV 36,400 15.50 12.50 0X34-44/48 EL296UH110XV60C 6508682 X016-036-230 TXV 36,200 15.50 12.20 0X34-44/48 SL280UH090V36B 6508310 XC16-036-230 TXV 36,200 15.00 12.50 0X34-44/48 SL280UH090V48B 6508316 X016-036-230 TXV 36,600 15.10 12.20 0X34-44/48 SL280UH090V60C 6508358 XC16-036-230 TXV 36,200 15.50 12.50 0X34-44/48 SL280UH090XV48B 6508637 XC16-036-230 TXV 36,600 15.10 12.20 0X34-44/48 SL280UH090XV60C 6508659 X016-036-230 TXV 36,400 15.10 12.20 0X34-44/48 SL280UH110V60C 6508364 XC16-036-230 TXV 36,400 15.10 12.20 0X34-44/48 SL280UH110XV60C 6508668 X016-036-230 TXV 36,000 15.50 12.00 0X34-44/48 SLP98UH070XV36B 6508322 XC16-036-230 TXV 36,200 15.50 12.50 0X34-44/48 SLP98UH090XV36C 6508370 X016-036-230 TXV 36,400 15.50 12.20 0X34-44/48 SLP98UH090XV48C 6508376 XC16-036-230 TXV 36,600 15.50 12.20 0X34-44/48 SLP98UH090XV60C 6508381 XC16-036-230 TXV 36,400 15.50 12.50 0X34-44/48 SLP98UH110XV60C 6508387 XC16-036-230 TXV 36,400 14.00 11.70 CX34-49 6508393 X016-036-230 TXV 37,000 15.50 12.50 0X34-49 EL296UH090XV36C 6508688 XC16-036-230 TXV 36,800 16.00 12.50 0X34-49 EL296UH090XV48C 6508704 X016-036-230 TXV 37,600 16.00 12.50 0X34-49 EL296UH090XV60C 6508691 XC16-036-230 TXV 37,400 16.00 12.50 0X34-49 EL296UH110XV60C 6508710 X016-036-230 TXV 37,600 16.00 12.50 0X34-49 SL280UH090V60C 6508398 X016-036-230 TXV 37,600 16.00 12.50 0X34-49 SL280UH090XV60C 6508707 XC16-036-230 TXV 37,200 15.10 12.50 0X34-49 SL280UH110V60C 6508405 XC16-036-230 TXV 37,400 15.10 12.50 0X34-49 SL280UH110XV60C 6508701 XC16-036-230 TXV 37,000 16.00 12.50 0X34-49 SLP98UH090XV36C 6508411 XC16-036-230 TXV 37,400 16.00 12.50 0X34-49 SLP98UH090XV48C 6508417 X016-036-230 TXV 37,600 16.00 12.50 0X34-49 SLP98UH090XV60C 6508422 X016-036-230 TXV 37,400 16.00 12.50 0X34-49 SLP98UH110XV60C 6508428 X016-036-230 TXV 36,400 16.00 12.50 CX34-50/600 EL296UH110XV48C 6508434 XC16-048-230 TXV 46,000 15.50 12.00 033-43 EL180UH090E48B 6685351 X016-048-230 TXV 44,500 14.00 11.00 033-48 6685137 XC16-048-230 TXV 45,000 15.00 11.70 033-48 EL180UH090E48B 6685360 X016-048-230 TXV 45,000 15.50 12.00 033-48 EL180UH090E60C 6685361 X016-048-230 TXV 44,500 15.00 11.70 033-48 EL180UH110E60C 6685364 X016-048-230 TXV 44,500 15.00 11.70 033-48 EL195UH090XE48C 6685275 X016-048-230 TXV 45,000 15.00 11.50 033-48 EL195UH110XE60C 6689566 XC16-048-230 TXV 44,500 15.00 11.50 033-48 EL296UH090XE48C 6685366 X016-048-230 TXV 44,500 15.00 11.50 033-48 EL296UH090XV48C 6685256 X016-048-230 TXV 44,500 15.00 11.50 033-48 EL296UH090XV60C 6685258 X016-048-230 TXV 45,000 15.00 11.70 033-48 EL296UH110XE60C 6685368 X016-048-230 TXV 44,500 15.00 11.50 033-48 EL296UH110XV48C 6685260 X016-048-230 TXV 45,000 15.00 11.50 033-48 EL296UH110XV60C 6685262 X016-048-230 TXV 45,000 15.50 11.70 033-48 SL280UH090V60C 6685264 X016-048-230 TXV 45,000 15.50 11.70 033-48 SL280UH090XV60C 6685370 X016-048-230 TXV 45,000 15.00 11.70 033-48 SL280UH110V60C 6685266 XC16-048-230 TXV 44,500 15.00 11.70 033-48 SL280UH110XV60C 6685371 X016-048-230 TXV 45,000 15.00 11.50 033-48 SL0185B124/141V60 7110158 X016-048-230 TXV 45,000 14.50 11.50 033-48 SL0185UF124/1 � Ratings AHRI Certified to AHRI Standard 210/240(with 25 ft.of connecting refrigerant lines);95°F outdoor air temperature,80°F db/67°F wb y r All ratings include the use of a blower time delay relay(TDR).All Lennox variable-speed furnaces and Air Handlers have time delay capabilities.Other Furnaces and Air Handlers may require an optional time delay relay(58M81)for field installation.See furnace or air handler specifications to determine if relay is need.".O/O 9/1 8 Also see Expansion Valve Kit Usage Table. XC1ti-2to5 Ton Air6qn�{� ,1 g M NT AHRI SYSTEM MATCHES NOTE-For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model Expansion Coil or AHRI No. Device Capacity SEER EER Air Handler Furnace Reference XC16-048-230 TXV 44,500 15.00 11.50 033-48 SLP98UH090XV48C 6685268 XC16-048-230 TXV 44,500 15.00 11.50 C33-48 SLP98UH090XV60C 6685270 XC16-048-230 TXV 45,000 15.00 11.50 C33-48 SLP98UH110XV60C 6685272 X016-048-230 TXV 46,500 14.50 11.70 C33-49 6685139 XC16-048-230 TXV 46,500 16.00 12.00 C33-49 EL180UH090E60C 6685380 X016-048-230 TXV 46,500 16.00 12.00 C33-49 EL180UH110E60C 6685381 XC16-048-230 TXV 46,500 15.50 12.20 033-49 EL195UH090XE48C 6685277 X016-048-230 TXV 46,500 16.00 12.00 033-49 EL195UH110XE60C 6685279 XC16-048-230 TXV 46,500 15.50 12.00 033-49 EL296UH090XE48C 6685384 XC16-048-230 TXV 46,500 16.00 12.00 033-49 EL296UH090XV48C 6685281 XC16-048-230 TXV 46,500 15.50 12.00 033-49 EL296UH090XV60C 6685283 XC16-048-230 TXV 46,500 16.00 12.00 033-49 EL296UH110XE60C 6685385 XC16-048-230 TXV 46,500 16.00 12.00 033-49 EL296UH110XV48C 6685285 XC16-048-230 TXV 46,500 16.00 12.00 033-49 EL296UH110XV60C 6685287 XC16-048-230 TXV 47,000 16.00 12.00 033-49 SL280UH090V60C 6685289 XC16-048-230 TXV 46,500 16.00 12.00 033-49 SL280UH090XV60C 6685388 X016-048-230 TXV 46,500 16.00 12.00 033-49 SL280UH110V60C 6685291 X016-048-230 TXV 46,500 16.00 12.00 033-49 SL280UH110XV60C 6685389 X016-048-230 TXV 46,500 15.50 12.20 033-49 SL0185B124/141V60 7110163 X016-048-230 TXV 46,500 15.50 12.20 033-49 SL0185UF124/141V60 7110161 X016-048-230 TXV 46,500 16.00 12.00 033-49 SLP98UH090XV48C 6685293 X016-048-230 TXV 46,500 16.00 12.00 033-49 SLP98UH090XV60C 6685295 X016-048-230 TXV 46,500 16.00 12.00 033-49 SLP98UH110XV60C 6685296 X016-048-230 TXV 45,000 14.00 11.00 033-50/600 6685141 X016-048-230 TXV 45,500 15.50 11.70 033-50/600 CBWMV-600-100 6685397 X016-048-230 TXV 45,500 15.50 12.00 033-50/600 EL180UH090E60C 6685400 X016-048-230 TXV 45,000 15.50 12.00 033-50/600 EL180UH110E60C 6685401 XC16-048-230 TXV 45,000 15.00 11.70 033-50/600 EL195UH090XE48C 6685298 XC16-048-230 TXV 45,500 15.00 11.50 033-50/600 EL195UH110XE60C 6685300 XC16-048-230 TXV 45,500 15.00 11.70 033-50/600 EL296UH090XE48C 6685404 XC16-048-230 TXV 45,500 15.50 11.70 033-50/600 EL296UH090XV48C 6685302 XC16-048-230 TXV 45,500 15.00 11.70 033-50/600 EL296UH090XV60C 6685304 X016-048-230 TXV 45,500 15.50 12.00 033-50/600 EL296UH110XE60C 6685405 X016-048-230 TXV 45,000 15.50 11.70 033-50/600 EL296UH110XV48C 6685306 XC16-048-230 TXV 45,500 15.50 11.70 033-50/600 EL296UH110XV60C 6685308 X016-048-230 TXV 45,500 15.50 11.70 033-50/600 SL280UH090V60C 6685310 XC16-048-230 TXV 45,500 15.50 11.70 033-50/600 SL280UH090XV60C 6685407 X016-048-230 TXV 45,500 15.50 11.70 033-50/600 SL280UH110V60C 6685312 X016-048-230 TXV 45,500 15.50 11.70 033-50/600 SL280UH110XV60C 6685410 X016-048-230 TXV 45,000 15.00 11.50 033-50/600 SL0185B124/141V60 7110165 X016-048-230 TXV 45,000 15.00 11.50 033-50/600 SL0185UF124/141V60 7110168 XC16-048-230 TXV 45,500 15.50 11.70 033-50/600 SLP98UH090XV48C 6685314 XC16-048-230 TXV 45,500 15.50 11.70 033-50/600 SLP98UH090XV60C 6685316 XC16-048-230 TXV 45,500 15.50 11.70 033-50/600 SLP98UH110XV60C 6685318 XC16-048-230 TXV 46,000 14.50 11.50 033-60D 6685143 X016-048-230 TXV 46,500 16.00 12.00 033-60D EL296UH135XV6OD 6685320 XC16-048-230 TXV 46,500 16.00 12.00 033-60D SL280UH135V6OD Ratings AHRI Certified to AHRI Standard 210/240(with 25 ft.of connecting refrigerant lines);95°F outdoor air temperature,80°F db/67°F wb enterinRE"f"a �VE All ratings include the use of a blower time delay relay(TDR).All Lennox variable-speed furnaces and Air Handlers have time delay capabilities.Other Furnaces and Air Handlers may require an optional time delay relay(58M81)for field installation.See furnace or air handler specifications to determine if relay is needed. 10/0 9/1 8 Also see Expansion Valve Kit Usage Table. XC16-2 to 5 Ton Air Conditioner /Page 24 ASPEN BUILDING DEPARTMENT AHRI SYSTEM MATCHES NOTE- For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model Expansion Coil or AHRI No. Device Capacity SEER EER Air Handler Furnace Reference XC16-048-230 TXV 46,000 15.50 12.00 033-60D SL0185B124/141V60 7110170 X016-048-230 TXV 46,000 15.50 12.00 033-60D SL0185UF124/141V60 7110172 X016-048-230 TXV 46,500 16.00 12.00 033-60D SLP98UH135XV6OD 6685324 X016-048-230 TXV 47,000 14.50 11.70 C33-62C 6685145 X016-048-230 TXV 47,000 16.00 12.50 033-620 EL180UH090E60C 6685424 X016-048-230 TXV 47,000 16.00 12.50 C33-62C EL180UH110E60C 6685425 XC16-048-230 TXV 47,000 16.00 12.00 033-620 EL195UH090XE48C 6685326 X016-048-230 TXV 47,000 16.00 12.00 C33-620 EL195UH110XE60C 6685328 XC16-048-230 TXV 47,000 16.00 12.00 033-620 EL296UH090XE48C 6685428 X016-048-230 TXV 47,000 16.00 12.00 033-620 EL296UH090XV48C 6685330 XC16-048-230 TXV 47,000 16.00 12.00 033-620 EL296UH090XV60C 6685332 X016-048-230 TXV 47,000 16.00 12.00 033-620 EL296UH110XE60C 6685429 XC16-048-230 TXV 47,000 16.00 12.00 033-620 EL296UH110XV48C 6685334 X016-048-230 TXV 47,500 16.00 12.00 033-620 EL296UH110XV60C 6685336 XC16-048-230 TXV 47,500 16.00 12.00 033-620 SL280UH090V60C 6685155 X016-048-230 TXV 47,000 16.00 12.00 033-620 SL280UH090XV60C 6685432 XC16-048-230 TXV 47,000 16.00 12.00 033-620 SL280UH110V60C 6685338 X016-048-230 TXV 47,000 16.00 12.00 033-620 SL280UH110XV60C 6685433 XC16-048-230 TXV 47,000 16.00 12.00 033-620 SL0185B124/141V60 7110174 X016-048-230 TXV 47,000 16.00 12.00 033-620 SL0185UF124/141V60 7110175 X016-048-230 TXV 47,000 16.00 12.00 033-620 SLP98UH090XV48C 6685340 X016-048-230 TXV 47,000 16.00 12.00 033-620 SLP98UH090XV60C 6685342 XC16-048-230 TXV 47,500 16.00 12.00 033-620 SLP98UH110XV60C 6685344 X016-048-230 TXV 46,500 14.50 11.70 033-62D 6685147 XC16-048-230 TXV 47,000 16.00 12.00 033-62D EL296UH135XV6OD 6685346 X016-048-230 TXV 47,000 16.00 12.00 033-62D SL280UH135V6OD 6685348 X016-048-230 TXV 46,500 15.50 12.20 033-62D SL0185B124/141V60 7110177 X016-048-230 TXV 46,500 15.50 12.20 033-62D SL0185UF124/141V60 7110180 X016-048-230 TXV 47,000 16.00 12.00 033-62D SLP98UH135XV6OD 6685350 X016-048-230 TXV 46,000 14.00 11.50 CBX25UH-048 6685160 X016-048-230 TXV 46,000 13.00 11.00 CBX25UH-060 6685161 X016-048-230 TXV 47,000 16.00 12.00 CBX25UHV-048 6970139 X016-048-230 TXV 46,000 16.00 12.00 CBX27UH-048 6685156 X016-048-230 TXV 46,500 16.00 12.00 CBX27UH-060 6685157 X016-048-230 TXV 46,000 15.00 12.00 CBX32M-048 6685162 X016-048-230 TXV 47,000 14.00 12.00 CBX32M-060 6685163 X016-048-230 TXV 46,000 16.00 12.00 CBX32MV-048 6685164 X016-048-230 TXV 47,000 16.00 12.00 CBX32MV-060 6685165 X016-048-230 TXV 47,000 16.00 12.00 CBX32MV-068 6685166 X016-048-230 TXV 45,500 15.50 12.00 CBX4OUHV-048 6685441 X016-048-230 TXV 46,000 15.50 12.00 CBX4OUHV-060 6685442 X016-048-230 TXV 43,500 13.00 11.00 0H23-51 6685148 X016-048-230 TXV 44,000 14.50 11.50 0H23-51 EL180UH090E48B 6685445 X016-048-230 TXV 44,000 15.00 11.70 0H23-51 EL180UH090E60C 6685446 X016-048-230 TXV 43,500 15.00 11.70 0H23-51 EL180UH110E60C 6685447 X016-048-230 TXV 44,000 14.50 11.50 0H23-51 EL195UH090XE48C 6685167 XC16-048-230 TXV 44,000 15.00 11.70 0H23-51 EL195UH110XE`�;,♦ Ratings AHRI Certified to AHRI Standard 210/240(with 25 ft.of connecting refrigerant lines);95°F outdoor air temperature,80°F db/67°F wb`•-1/ •. rAt,r I) All ratings include the use of a blower time delay relay(TDR).All Lennox variable-speed furnaces and Air Handlers have time delay capabilities.Other Furnaces and Air Handlers may require an optional time delay relay(58M81)for field installation.See furnace or air handler specifications to determine if relay is need.".O/O 9/1 8 Also see Expansion Valve Kit Usage Table. XC1ti-2to5 Ton Air6q1I 1 ,1 g ,ZENT AHRI SYSTEM MATCHES NOTE-For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model Expansion Coil or AHRI No. Device Capacity SEER EER Air Handler Furnace Reference XC16-048-230 TXV 44,000 14.50 11.50 0H23-51 EL296UH090XE48C 6685443 XC16-048-230 TXV 44,000 15.00 11.50 CH23-51 EL296UH090XV48C 6685169 XC16-048-230 TXV 44,000 15.00 11.50 CH23-51 EL296UH090XV60C 6685170 XC16-048-230 TXV 44,000 15.00 11.70 CH23-51 EL296UH110XE60C 6685444 XC16-048-230 TXV 44,000 15.00 11.50 CH23-51 EL296UH110XV48C 6685171 XC16-048-230 TXV 44,000 15.00 11.50 CH23-51 EL296UH110XV60C 6685172 XC16-048-230 TXV 44,000 15.00 11.50 0H23-51 EL296UH135XV6OD 6685173 XC16-048-230 TXV 44,000 15.00 11.50 0H23-51 SL280UH090V60C 6685175 XC16-048-230 TXV 44,000 15.00 11.70 0H23-51 SL280UH090XV60C 6685448 XC16-048-230 TXV 44,000 15.00 11.70 CH23-51 SL280UH110V60C 6685176 XC16-048-230 TXV 44,000 15.00 11.70 0H23-51 SL280UH110XV60C 6685449 XC16-048-230 TXV 44,000 15.00 11.50 0H23-51 SL280UH135V6OD 6685177 XC16-048-230 TXV 44,000 15.00 11.50 0H23-51 SLP98UH090XV48C 6685178 XC16-048-230 TXV 44,000 15.00 11.50 0H23-51 SLP98UH090XV60C 6685179 XC16-048-230 TXV 44,000 15.00 11.50 0H23-51 SLP98UH110XV60C 6685180 XC16-048-230 TXV 44,000 15.00 11.50 0H23-51 SLP98UH135XV6OD 6685181 XC16-048-230 TXV 44,000 13.00 11.00 0H23-65 6685149 XC16-048-230 TXV 44,500 15.00 11.70 CH23-65 EL180UH090E60C 6685452 XC16-048-230 TXV 44,500 15.00 11.70 0H23-65 EL180UH110E60C 6685453 XC16-048-230 TXV 44,500 15.00 11.70 0H23-65 EL195UH090XE48C 6685182 XC16-048-230 TXV 44,500 15.00 11.70 0H23-65 EL195UH110XE60C 6685183 XC16-048-230 TXV 44,500 15.00 11.50 CH23-65 EL296UH090XE48C 6685450 XC16-048-230 TXV 44,500 15.50 11.70 0H23-65 EL296UH090XV48C 6685184 XC16-048-230 TXV 44,500 15.50 11.70 CH23-65 EL296UH090XV60C 6685185 XC16-048-230 TXV 44,500 15.00 11.70 0H23-65 EL296UH110XE60C 6685451 XC16-048-230 TXV 44,500 15.50 11.70 CH23-65 EL296UH110XV48C 6685186 XC16-048-230 TXV 44,500 15.50 11.70 CH23-65 EL296UH110XV60C 6685187 XC16-048-230 TXV 45,000 15.50 12.00 CH23-65 EL296UH135XV6OD 6685188 XC16-048-230 TXV 45,000 15.50 12.00 CH23-65 SL280UH090V60C 6677936 XC16-048-230 TXV 45,000 15.50 12.00 CH23-65 SL280UH090XV48B 6685494 XC16-048-230 TXV 44,500 15.50 11.70 CH23-65 SL280UH110V60C 6677937 XC16-048-230 TXV 44,500 15.50 11.70 CH23-65 SL280UH110XV60C 6685495 XC16-048-230 TXV 45,000 15.50 12.00 CH23-65 SL280UH135V6OD 6685189 XC16-048-230 TXV 44,500 15.50 11.70 CH23-65 SLP98UH090XV48C 6685190 XC16-048-230 TXV 44,500 15.50 11.70 CH23-65 SLP98UH090XV60C 6685191 XC16-048-230 TXV 45,000 15.50 11.70 CH23-65 SLP98UH110XV60C 6685192 XC16-048-230 TXV 45,000 15.50 12.00 CH23-65 SLP98UH135XV6OD 6685193 XC16-048-230 TXV 46,000 14.00 11.50 CH23-68 6685131 XC16-048-230 TXV 46,500 15.50 12.20 0H23-68 EL180UH090E60C 6685454 XC16-048-230 TXV 46,000 15.50 12.20 0H23-68 EL180UH110E60C 6685455 XC16-048-230 TXV 46,500 15.50 12.20 0H23-68 EL195UH090XE48C 6685194 XC16-048-230 TXV 46,500 16.00 12.00 0H23-68 EL195UH110XE60C 6685195 XC16-048-230 TXV 46,000 15.50 12.00 0H23-68 EL296UH090XE48C 6685456 XC16-048-230 TXV 46,000 15.50 12.00 0H23-68 EL296UH110XE60C 6685457 XC16-048-230 TXV 46,500 16.00 12.00 0H23-68 EL296UH135XV6OD 6685196 XC16-048-230 TXV 46,500 16.00 12.00 CH23-68 SL280UH135V6OD 6685197 XC16-048-230 TXV 46,500 16.00 12.00 CH23-68 SLP98UH135XV6OD ���� Ratings AHRI Certified to AHRI Standard 210/240(with 25 ft.of connecting refrigerant lines);95°F outdoor air temperature,80°F db/67°F wb enterin ,. All ratings include the use of a blower time delay relay(TDR).All Lennox variable-speed furnaces and Air Handlers have time delay capabilities.Other Furnaces and Air Handlers may require an optional time delay relay(58M81)for field installation.See furnace or air handler specifications to determine if relay is needed. 10/0 9/1 8 Also see Expansion Valve Kit Usage Table. XC16-2 to 5 Ton Air Conditioner /Page 26 ASPEN BUILDING DEPARTMENT AHRI SYSTEM MATCHES NOTE- For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model Expansion Coil or AHRI No. Device Capacity SEER EER Air Handler Furnace Reference XC16-048-230 TXV 46,500 15.50 12.00 0H33-43 SL280UH090V48B 6685458 XC16-048-230 TXV 46,500 15.50 12.00 CH33-43 SL280UH090XV48B 6685459 XC16-048-230 TXV 46,000 15.50 12.20 0H33-430 EL180UH090E60C 6677938 XC16-048-230 TXV 45,500 15.50 12.20 CH33-43C EL180UH110E60C 6677939 XC16-048-230 TXV 45,500 15.00 11.70 0H33-430 EL195UH090XE48C 6685199 XC16-048-230 TXV 46,000 15.00 11.70 CH33-430 EL195UH110XE60C 6685200 XC16-048-230 TXV 45,500 15.50 11.70 0H33-430 EL296UH090XE48C 6685460 XC16-048-230 TXV 46,000 15.50 12.00 0H33-430 EL296UH110XE60C 6685461 XC16-048-230 TXV 45,500 15.50 11.70 0H33-430 EL296UH110XV48C 6685201 XC16-048-230 TXV 45,500 15.50 11.70 0H33-44/48 EL180UH090E48B 6685462 XC16-048-230 TXV 45,000 15.00 11.50 0H33-44/48 SL280UH090V48B 6685463 XC16-048-230 TXV 45,000 15.00 11.50 0H33-44/48 SL280UH090XV48B 6685464 XC16-048-230 TXV 45,500 15.50 11.70 0H33-48 EL296UH090XV48C 6685205 XC16-048-230 TXV 45,500 15.00 11.70 0H33-48 EL296UH090XV60C 6685206 XC16-048-230 TXV 45,500 15.50 11.70 CH33-48 EL296UH110XV48C 6685207 XC16-048-230 TXV 45,500 15.50 11.70 0H33-48 EL296UH110XV60C 6685208 XC16-048-230 TXV 45,500 15.50 11.70 0H33-48 SL280UH090V60C 6685209 XC16-048-230 TXV 45,500 15.50 11.70 0H33-48 SL280UH090XV60C 6685465 XC16-048-230 TXV 45,500 15.50 11.70 0H33-48 SL280UH110V60C 6685210 XC16-048-230 TXV 45,500 15.50 11.70 0H33-48 SL280UH110XV60C 6685466 XC16-048-230 TXV 45,500 15.50 11.70 0H33-48 SLP98UH090XV48C 6685211 XC16-048-230 TXV 45,500 15.50 11.70 0H33-48 SLP98UH090XV60C 6685212 XC16-048-230 TXV 45,500 15.50 11.70 0H33-48 SLP98UH110XV60C 6685213 XC16-048-230 TXV 45,000 14.00 11.00 0H33-480 6685132 XC16-048-230 TXV 45,500 15.50 12.00 0H33-480 EL180UH090E60C 6685467 XC16-048-230 TXV 45,500 15.50 12.20 0H33-480 EL180UH110E60C 6685468 XC16-048-230 TXV 45,000 15.00 11.70 0H33-480 EL195UH090XE48C 6685203 XC16-048-230 TXV 46,000 15.00 11.70 CH33-48C EL195UH110XE60C 6685204 XC16-048-230 TXV 45,500 15.50 11.70 0H33-480 EL296UH090XE48C 6685469 XC16-048-230 TXV 45,500 15.50 12.00 0H33-480 EL296UH110XE60C 6685470 XC16-048-230 TXV 46,000 14.50 11.50 0H33-49 6685150 XC16-048-230 TXV 46,500 15.50 12.00 0H33-49 EL296UH090XV48C 6685214 XC16-048-230 TXV 46,500 15.50 12.00 0H33-49 EL296UH090XV60C 6685215 XC16-048-230 TXV 46,500 15.50 12.00 0H33-49 EL296UH110XV48C 6685216 XC16-048-230 TXV 46,500 15.50 12.00 0H33-49 EL296UH110XV60C 6685217 XC16-048-230 TXV 46,500 16.00 12.00 0H33-49 SL280UH090V60C 6685218 XC16-048-230 TXV 46,500 16.00 12.00 0H33-49 SL280UH090XV60C 6685471 XC16-048-230 TXV 46,500 15.50 12.00 0H33-49 SL280UH110V60C 6685219 XC16-048-230 TXV 46,500 15.50 12.00 0H33-49 SL280UH110XV60C 6685472 XC16-048-230 TXV 46,500 15.50 12.00 0H33-49 SLP98UH090XV48C 6685220 XC16-048-230 TXV 46,500 15.50 12.00 0H33-49 SLP98UH090XV60C 6685221 XC16-048-230 TXV 46,500 15.50 12.00 0H33-49 SLP98UH110XV60C 6685222 XC16-048-230 TXV 46,000 14.50 11.50 0H33-50/600 6685133 XC16-048-230 TXV 46,000 15.50 11.70 0H33-50/600 CBWMV-60C-100 6685473 XC16-048-230 TXV 46,000 16.00 12.00 0H33-50/60C EL180UH090E60C 6685474 XC16-048-230 TXV 46,000 16.00 12.00 0H33-50/600 EL180UH110E60C 6685475e XC16 048 230 TXV 46,000 15.50 12.00 0H33 50/60C EL195UH090XE 'r � � ) Ratings AHRI Certified to AHRI Standard 210/240(with 25 ft.of connecting refrigerant lines);95°F outdoor air temperature,80°F db/67°F wb i[ng @y r All ratings include the use of a blower time delay relay(TDR).All Lennox variable-speed furnaces and Air Handlers have time delay capabilities.Other Furnaces and Air Handlers may require an optional time delay relay(58M81)for field installation.See furnace or air handler specifications to determine if relay is need.".O/O 9/1 8 Also see Expansion Valve Kit Usage Table. e�p XC16-2 to 5 Ton Air611tl ti �P MtNT AHRI SYSTEM MATCHES NOTE-For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model Expansion Coil or AHRI No. Device Capacity SEER EER Air Handler Furnace Reference XC16-048-230 TXV 46,500 15.50 11.70 0H33-50/60C EL195UH110XE60C 6685224 XC16-048-230 TXV 46,000 15.50 12.00 CH33-50/60C EL296UH090XE48C 6677940 XC16-048-230 TXV 46,000 15.50 12.00 CH33-50/60C EL296UH090XE48C 6685496 XC16-048-230 TXV 46,000 15.50 11.70 CH33-50/600 EL296UH090XV48C 6685225 XC16-048-230 TXV 46,000 15.50 11.70 CH33-50/60C EL296UH090XV60C 6685226 XC16-048-230 TXV 46,000 15.50 12.00 CH33-50/60C EL296UH110XE60C 6677941 XC16-048-230 TXV 46,000 15.50 12.00 0H33-50/600 EL296UH110XE60C 6685497 XC16-048-230 TXV 46,000 15.50 12.00 0H33-50/600 EL296UH110XV48C 6685227 XC16-048-230 TXV 46,000 15.50 11.70 0H33-50/60C EL296UH110XV60C 6685228 XC16-048-230 TXV 46,500 16.00 12.00 CH33-50/60C SL280UH090V60C 6685229 XC16-048-230 TXV 46,500 15.50 12.20 0H33-50/60C SL280UH090XV60C 6685476 XC16-048-230 TXV 46,000 15.50 12.00 0H33-50/600 SL280UH110V60C 6685230 XC16-048-230 TXV 46,000 15.50 12.00 0H33-50/600 SL280UH110XV60C 6685477 XC16-048-230 TXV 46,000 15.50 11.70 0H33-50/60C SLP98UH090XV48C 6685231 XC16-048-230 TXV 46,000 15.50 11.70 0H33-50/600 SLP98UH090XV60C 6685232 XC16-048-230 TXV 46,000 15.50 11.70 0H33-50/60C SLP98UH110XV60C 6685233 XC16-048-230 TXV 45,500 14.00 11.50 0H33-60D 6685134 XC16-048-230 TXV 46,000 16.00 12.00 CH33-60D EL296UH135XV6OD 6685234 XC16-048-230 TXV 46,000 16.00 12.00 0H33-60D SL280UH135V6OD 6685235 XC16-048-230 TXV 46,000 15.50 12.00 0H33-60D SLP98UH135XV6OD 6685236 XC16-048-230 TXV 46,000 14.50 11.50 0H33-62D 6685135 XC16-048-230 TXV 46,500 16.00 12.00 CH33-62D EL296UH135XV6OD 6685237 XC16-048-230 TXV 46,500 16.00 12.00 0H33-62D SL280UH135V6OD 6685238 XC16-048-230 TXV 46,500 16.00 12.00 CH33-62D SLP98UH135XV6OD 6685239 XC16-048-230 TXV 46,500 14.50 11.70 0H35-42B 7166463 XC16-048-230 TXV 47,000 15.50 12.00 CH35-42B SL280UH090V48B 7166465 XC16-048-230 TXV 47,000 15.50 12.00 CH35-42B SL280UH090XV48B 7166466 XC16-048-230 TXV 46,000 14.50 11.50 CH35-42C 7166464 XC16-048-230 TXV 46,000 15.50 12.00 CH35-42C EL180UH090E60C 7166467 XC16-048-230 TXV 46,000 15.50 12.00 CH35-42C EL180UH110E60C 7166468 XC16-048-230 TXV 45,500 15.10 11.70 0H35-420 EL195UH090XE48C 7166469 XC16-048-230 TXV 46,500 15.10 11.70 CH35-42C EL195UH110XE60C 7166470 XC16-048-230 TXV 46,000 15.50 12.00 CH35-42C EL296UH090XE48C 7166471 XC16-048-230 TXV 46,000 15.50 12.00 CH35-42C EL296UH110XE60C 7166473 XC16-048-230 TXV 46,000 15.50 12.00 CH35-42C EL296UH110XV48C 7166472 XC16-048-230 TXV 45,500 14.25 11.50 CH35-48B 7166477 XC16-048-230 TXV 45,500 15.50 11.70 CH35-48B EL180UH090E48B 7166474 XC16-048-230 TXV 45,500 15.10 11.50 CH35-48B SL280UH090V48B 7166475 XC16-048-230 TXV 45,500 15.10 11.50 CH35-48B SL280UH090XV48B 7166476 XC16-048-230 TXV 45,500 14.25 11.50 0H35-48C 7166478 XC16-048-230 TXV 46,000 15.50 12.00 0H35-48C EL180UH090E60C 7166479 XC16-048-230 TXV 45,500 15.50 12.00 0H35-480 EL180UH110E60C 7166480 XC16-048-230 TXV 45,500 15.10 11.70 0H35-48C EL195UH090XE48C 7166481 XC16-048-230 TXV 46,000 15.10 11.70 0H35-480 EL195UH110XE60C 7166482 XC16-048-230 TXV 45,500 15.50 11.70 0H35-480 EL296UH090XV48C 7166483 XC16-048-230 TXV 45,500 15.10 11.70 CH35-480 EL296UH090XV60C 7166484 XC16-048-230 TXV 46,000 15.50 12.00 CH35-48C EL296UH110XE60C 0. Ratings AHRI Certified to AHRI Standard 210/240(with 25 ft.of connecting refrigerant lines);95°F outdoor air temperature,80°F db/67°F wb entering@'•_. !m �VE All ratings include the use of a blower time delay relay(TDR).All Lennox variable-speed furnaces and Air Handlers have time delay capabilities.Other Furnaces and Air Handlers may require an optional time delay relay(58M81)for field installation.See furnace or air handler specifications to determine if relay is needed. 10/0 9/1 8 Also see Expansion Valve Kit Usage Table. XC16-2 to 5 Ton Air Conditioner /Page 28 ASPEN BUILDING DEPARTMENT AHRI SYSTEM MATCHES NOTE- For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model Expansion Coil or AHRI No. Device Capacity SEER EER Air Handler Furnace Reference XC16-048-230 TXV 45,500 15.50 11.70 0H35-480 EL296UH110XV48C 7166485 XC16-048-230 TXV 46,000 15.50 11.70 CH35-480 EL296UH110XV60C 7166486 XC16-048-230 TXV 46,000 15.50 12.00 0H35-480 SL280UH090V60C 7165614 XC16-048-230 TXV 46,000 15.50 12.00 0H35-480 SL280UH090XV60C 7166488 XC16-048-230 TXV 45,500 15.50 11.70 0H35-480 SL280UH110V60C 7165615 XC16-048-230 TXV 45,500 15.50 11.70 CH35-48C SL280UH110XV60C 7166489 XC16-048-230 TXV 45,500 15.50 11.70 0H35-480 SLP98UH090XV48C 7165616 XC16-048-230 TXV 45,500 15.50 11.70 0H35-480 SLP98UH090XV60C 7165617 XC16-048-230 TXV 46,000 15.50 11.70 0H35-480 SLP98UH110XV60C 7165618 XC16-048-230 TXV 46,500 14.50 11.70 0H35-510 7166496 XC16-048-230 TXV 46,500 15.50 12.00 0H35-51C CBWMV-600-100 7166497 XC16-048-230 TXV 46,500 16.00 12.00 0H35-510 EL180UH090E60C 7166498 XC16-048-230 TXV 46,500 16.00 12.00 0H35-51C EL180UH110E60C 7166499 XC16-048-230 TXV 46,000 15.50 12.00 0H35-510 EL195UH090XE48C 7166500 XC16-048-230 TXV 47,000 15.50 11.70 CH35-510 EL195UH110XE60C 7166501 XC16-048-230 TXV 46,500 15.50 12.00 0H35-510 EL296UH090XV48C 7166490 XC16-048-230 TXV 46,500 15.50 12.00 0H35-510 EL296UH090XV60C 7166491 XC16-048-230 TXV 46,500 16.00 12.00 0H35-510 EL296UH110XE60C 7166502 XC16-048-230 TXV 46,500 15.50 12.00 0H35-510 EL296UH110XV48C 7166492 XC16-048-230 TXV 46,500 15.50 12.00 0H35-510 EL296UH110XV60C 7166493 XC16-048-230 TXV 46,500 16.00 12.00 0H35-510 SL280UH090V60C 7165619 XC16-048-230 TXV 46,500 16.00 12.00 0H35-51C SL280UH090XV60C 7166494 XC16-048-230 TXV 46,500 15.50 12.00 0H35-510 SL280UH110V60C 7165620 XC16-048-230 TXV 46,500 15.50 12.00 0H35-510 SL280UH110XV60C 7166495 XC16-048-230 TXV 46,500 15.50 12.00 0H35-510 SLP98UH090XV48C 7165621 XC16-048-230 TXV 46,500 15.50 12.00 0H35-510 SLP98UH090XV60C 7165622 XC16-048-230 TXV 46,500 15.50 12.00 0H35-510 SLP98UH110XV60C 7165623 XC16-048-230 TXV 46,000 14.50 11.50 CH35-60D 7166503 XC16-048-230 TXV 47,000 16.00 12.00 0H35-60D EL296UH135XV6OD 7166504 XC16-048-230 TXV 46,500 16.00 12.00 0H35-60D SL280UH135V6OD 7165624 XC16-048-230 TXV 46,500 16.00 12.00 0H35-60D SLP98UH135XV6OD 7165625 XC16-048-230 TXV 44,000 14.00 11.00 CR33-48 6685151 XC16-048-230 TXV 44,500 15.00 11.70 0R33-48 EL180DF110E60C 6685243 XC16-048-230 TXV 44,000 15.00 11.50 0R33-48 EL195DF090XE48C 6685240 XC16-048-230 TXV 44,500 15.00 11.00 0R33-48 EL195DF110XE60C 6689565 XC16-048-230 TXV 44,500 15.00 11.50 0R33-48 EL296DF090XE48C 6685479 XC16-048-230 TXV 44,500 15.00 11.00 0R33-48 EL296DF090XV60C 6685241 XC16-048-230 TXV 44,500 15.00 11.70 0R33-48 EL296DF110XE60C 6685480 XC16-048-230 TXV 44,500 15.00 11.00 0R33-48 EL296DF110XV60C 6685242 XC16-048-230 TXV 44,500 15.00 11.70 0R33-48 SL280DF090V60C 6685244 XC16-048-230 TXV 44,500 15.50 11.70 0R33-48 SL280DF110V60C 6685245 XC16-048-230 TXV 44,500 15.00 11.00 0R33-48 SLP98DF090XV48C 6685481 XC16-048-230 TXV 44,500 15.00 11.00 0R33-48 SLP98DF090XV60C 6685482 XC16-048-230 TXV 44,500 15.00 11.50 0R33-48 SLP98DF110XV60C 6685483 XC16-048-230 TXV 44,500 14.00 11.00 0R33-50/60 6685152 XC16-048-230 TXV 45,000 15.50 12.00 0R33-50/60 EL180DF110E60C 6685484 XC16-048-230 TXV 45,000 15.00 11.70 0R33-50/60 EL195DF090XE � Ratings AHRI Certified to AHRI Standard 210/240(with 25 ft.of connecting refrigerant lines);95°F outdoor air temperature,80°F db/67°F wb y�E r All ratings include the use of a blower time delay relay(TDR).All Lennox variable-speed furnaces and Air Handlers have time delay capabilities.Other Furnaces and Air Handlers may require an optional time delay relay(58M81)for field installation.See furnace or air handler specifications to determine if relay is need/.0/0 9/1 8 Also see Expansion Valve Kit Usage Table. LXC1ti-2to5TonAir6q� �{� E ,Z ENT AHRI SYSTEM MATCHES NOTE-For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model Expansion Coil or AHRI No. Device Capacity SEER EER Air Handler Furnace Reference XC16-048-230 TXV 45,000 15.00 11.70 0R33-50/60 EL195DF110XE60C 6685247 XC16-048-230 TXV 45,000 15.00 11.70 CR33-50/60 EL296DF090XE48C 6685485 XC16-048-230 TXV 45,000 15.00 11.70 CR33-50/60 EL296DF090XV60C 6685248 XC16-048-230 TXV 45,000 15.00 11.70 CR33-50/60 EL296DF110XE60C 6685486 XC16-048-230 TXV 45,000 15.00 11.50 CR33-50/60 EL296DF110XV60C 6685249 XC16-048-230 TXV 45,000 15.50 11.70 CR33-50/60 SL280DF090V60C 6685251 XC16-048-230 TXV 45,000 15.50 12.00 0R33-50/60 SL280DF110V60C 6685252 XC16-048-230 TXV 45,000 15.00 11.50 0R33-50/60 SLP98DF090XV48C 6685487 XC16-048-230 TXV 45,000 15.00 11.70 0R33-50/60 SLP98DF090XV60C 6685488 XC16-048-230 TXV 45,000 15.00 11.70 CR33-50/60 SLP98DF110XV60C 6685489 XC16-048-230 TXV 44,500 14.00 11.00 0R33-60 6685153 XC16-048-230 TXV 46,000 15.50 12.00 0X34-43 EL180UH090E48B 6685352 XC16-048-230 TXV 44,500 15.00 11.70 0X34-43 EL180UH110E60C 6685363 XC16-048-230 TXV 44,500 14.00 11.00 0X34-44/48 6685136 XC16-048-230 TXV 45,000 15.00 11.70 0X34-44/48 EL180UH090E48B 6685359 XC16-048-230 TXV 45,000 15.50 12.00 0X34-44/48 EL180UH090E60C 6685362 XC16-048-230 TXV 45,000 15.00 11.70 0X34-44/48 EL195UH090XE48C 6677932 XC16-048-230 TXV 45,000 15.00 11.70 CX34-44/48 EL195UH110XE60C 6677933 XC16-048-230 TXV 44,500 15.00 11.50 0X34-44/48 EL296UH090XE48C 6685365 XC16-048-230 TXV 44,500 15.00 11.50 0X34-44/48 EL296UH090XV48C 6685255 XC16-048-230 TXV 44,500 15.00 11.50 0X34-44/48 EL296UH090XV60C 6685257 XC16-048-230 TXV 45,000 15.00 11.70 CX34-44/48 EL296UH110XE60C 6685367 XC16-048-230 TXV 44,500 15.00 11.50 0X34-44/48 EL296UH110XV48C 6685259 XC16-048-230 TXV 45,000 15.00 11.50 CX34-44/48 EL296UH110XV60C 6685261 XC16-048-230 TXV 44,500 15.00 11.50 0X34-44/48 SL280UH090V48B 6677934 XC16-048-230 TXV 45,000 15.50 11.70 CX34-44/48 SL280UH090V60C 6685263 XC16-048-230 TXV 44,500 15.00 11.50 CX34-44/48 SL280UH090XV48B 6677935 XC16-048-230 TXV 45,000 15.50 11.70 CX34-44/48 SL280UH090XV60C 6685369 XC16-048-230 TXV 45,000 15.00 11.70 CX34-44/48 SL280UH110V60C 6685265 XC16-048-230 TXV 44,500 15.00 11.70 CX34-44/48 SL280UH110XV60C 6685372 XC16-048-230 TXV 45,000 15.00 11.50 CX34-44/48 SL0185B124/141V60 7110157 XC16-048-230 TXV 45,000 14.50 11.50 CX34-44/48 SL0185UF124/141V60 7110160 XC16-048-230 TXV 44,500 15.00 11.50 CX34-44/48 SLP98UH090XV48C 6685267 XC16-048-230 TXV 44,500 15.00 11.50 CX34-44/48 SLP98UH090XV60C 6685269 XC16-048-230 TXV 45,000 15.00 11.50 CX34-44/48 SLP98UH110XV60C 6685271 XC16-048-230 TXV 44,500 15.00 11.50 CX34-44/48B SL280UH090V48B 6685492 XC16-048-230 TXV 44,500 15.00 11.50 CX34-44/48B SL280UH090XV48B 6685493 XC16-048-230 TXV 45,000 15.00 11.70 0X34-44/480 EL195UH090XE48C 6685490 XC16-048-230 TXV 45,000 15.00 11.70 0X34-44/480 EL195UH110XE60C 6685491 XC16-048-230 TXV 46,500 14.50 11.70 0X34-49 6685138 XC16-048-230 TXV 46,500 16.00 12.00 0X34-49 EL180UH090E60C 6685379 XC16-048-230 TXV 46,500 16.00 12.00 0X34-49 EL180UH110E60C 6685382 XC16-048-230 TXV 46,500 15.50 12.20 0X34-49 EL195UH090XE48C 6685276 XC16-048-230 TXV 46,500 16.00 12.00 0X34-49 EL195UH110XE60C 6685278 XC16-048-230 TXV 46,500 15.50 12.00 0X34-49 EL296UH090XE48C 6685383 XC16-048-230 TXV 46,500 16.00 12.00 CX34-49 EL296UH090XV48C 6685280 XC16-048-230 TXV 46,500 15.50 12.00 CX34-49 EL296UH090XV60C ,. Ratings AHRI Certified to AHRI Standard 210/240(with 25 ft.of connecting refrigerant lines);95°F outdoor air temperature,80°F db/67°F wb enteringN.-fm �VE All ratings include the use of a blower time delay relay(TDR).All Lennox variable-speed furnaces and Air Handlers have time delay capabilities.Other Furnaces and Air Handlers may require an optional time delay relay(58M81)for field installation.See furnace or air handler specifications to determine if relay is needed. 10/0 9/1 8 Also see Expansion Valve Kit Usage Table. XC16-2 to 5 Ton Air Conditioner /Page 30 ASPEN BUILDING DEPARTMENT AHRI SYSTEM MATCHES NOTE- For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model Expansion Coil or AHRI No. Device Capacity SEER EER Air Handler Furnace Reference XC16-048-230 TXV 46,500 16.00 12.00 0X34-49 EL296UH110XE60C 6685386 XC16-048-230 TXV 46,500 16.00 12.00 0X34-49 EL296UH110XV48C 6685284 XC16-048-230 TXV 46,500 16.00 12.00 0X34-49 EL296UH110XV60C 6685286 XC16-048-230 TXV 47,000 16.00 12.00 0X34-49 SL280UH090V60C 6685288 XC16-048-230 TXV 46,500 16.00 12.00 0X34-49 SL280UH090XV60C 6685387 XC16-048-230 TXV 46,500 16.00 12.00 CX34-49 SL280UH110V60C 6685290 XC16-048-230 TXV 46,500 16.00 12.00 0X34-49 SL280UH110XV60C 6685390 XC16-048-230 TXV 46,500 15.50 12.20 0X34-49 SL0185B124/141V60 7110164 XC16-048-230 TXV 46,500 15.50 12.20 0X34-49 SL0185UF124/141V60 7110162 XC16-048-230 TXV 46,500 16.00 12.00 0X34-49 SLP98UH090XV48C 6685292 XC16-048-230 TXV 46,500 16.00 12.00 0X34-49 SLP98UH090XV60C 6685294 XC16-048-230 TXV 46,500 16.00 12.00 0X34-49 SLP98UH110XV60C 6677946 XC16-048-230 TXV 45,000 14.00 11.00 0X34-50/60C 6685140 XC16-048-230 TXV 45,500 15.50 11.70 0X34-50/600 CBWMV-60C-100 6685398 XC16-048-230 TXV 45,500 15.50 12.00 CX34-50/60C EL180UH090E60C 6685399 XC16-048-230 TXV 45,000 15.50 12.00 0X34-50/600 EL180UH110E60C 6685402 XC16-048-230 TXV 45,000 15.00 11.70 0X34-50/60C EL195UH090XE48C 6685297 XC16-048-230 TXV 45,500 15.00 11.50 0X34-50/600 EL195UH110XE60C 6685299 XC16-048-230 TXV 45,500 15.00 11.70 0X34-50/600 EL296UH090XE48C 6685403 XC16-048-230 TXV 45,500 15.50 11.70 0X34-50/600 EL296UH090XV48C 6685301 XC16-048-230 TXV 45,500 15.00 11.70 0X34-50/600 EL296UH090XV60C 6685303 XC16-048-230 TXV 45,500 15.50 12.00 0X34-50/600 EL296UH110XE60C 6685406 XC16-048-230 TXV 45,000 15.50 11.70 0X34-50/600 EL296UH110XV48C 6685305 XC16-048-230 TXV 45,500 15.50 11.70 0X34-50/600 EL296UH110XV60C 6685307 XC16-048-230 TXV 45,500 15.50 11.70 0X34-50/600 SL280UH090V60C 6685309 XC16-048-230 TXV 45,500 15.50 11.70 0X34-50/600 SL280UH090XV60C 6685408 XC16-048-230 TXV 45,500 15.50 11.70 0X34-50/600 SL280UH110V60C 6685311 XC16-048-230 TXV 45,500 15.50 11.70 CX34-50/600 SL280UH110XV60C 6685409 XC16-048-230 TXV 45,000 15.00 11.50 0X34-50/600 SL0185B124/141V60 7110166 XC16-048-230 TXV 45,000 15.00 11.50 0X34-50/600 SL0185UF124/141V60 7110167 XC16-048-230 TXV 45,500 15.50 11.70 0X34-50/600 SLP98UH090XV48C 6685313 XC16-048-230 TXV 45,500 15.50 11.70 0X34-50/600 SLP98UH090XV60C 6685315 XC16-048-230 TXV 45,500 15.50 11.70 0X34-50/600 SLP98UH110XV60C 6685317 XC16-048-230 TXV 46,000 14.50 11.50 0X34-60D 6685142 XC16-048-230 TXV 46,500 16.00 12.00 0X34-60D EL296UH135XV6OD 6685319 XC16-048-230 TXV 46,500 16.00 12.00 CX34-60D SL280UH135V6OD 6685321 XC16-048-230 TXV 46,000 15.50 12.00 0X34-60D SL0185B124/141V60 7110169 XC16-048-230 TXV 46,000 15.50 12.00 0X34-60D SL0185UF124/141V60 7110171 XC16-048-230 TXV 46,500 16.00 12.00 0X34-60D SLP98UH135XV6OD 6685323 XC16-048-230 TXV 47,000 14.50 11.70 0X34-620 6685144 XC16-048-230 TXV 47,000 16.00 12.50 0X34-620 EL180UH090E60C 6685423 XC16-048-230 TXV 47,000 16.00 12.50 0X34-620 EL180UH110E60C 6685426 XC16-048-230 TXV 47,000 16.00 12.00 0X34-620 EL195UH090XE48C 6685325 XC16-048-230 TXV 47,000 16.00 12.00 0X34-620 EL195UH110XE60C 6685327 XC16-048-230 TXV 47,000 16.00 12.00 0X34-620 EL296UH090XE48C 6685427 XC16-048-230 TXV 47,000 16.00 12.00 0X34-620 EL296UH090XV48C 6685329 XC16-048-230 TXV 47,000 16.00 12.00 0X34-620 EL296UH090XV I Ratings AHRI Certified to AHRI Standard 210/240(with 25 ft.of connecting refrigerant lines);95°F outdoor air temperature,80°F db/67°F wb`•Ill'•. � r � All ratings include the use of a blower time delay relay(TDR).All Lennox variable-speed furnaces and Air Handlers have time delay capabilities.Other Furnaces and Air Handlers may require an optional time delay relay(58M81)for field installation.See furnace or air handler specifications to determine if relay is need.".O/O 9/1 8 Also see Expansion Valve Kit Usage Table. XC16-2 to 5 Ton Air6qn�{� ,1 g ,$ENT AHRI SYSTEM MATCHES NOTE-For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model Expansion Coil or AHRI No. Device Capacity SEER EER Air Handler Furnace Reference XC16-048-230 TXV 47,000 16.00 12.00 0X34-620 EL296UH110XE60C 6685430 XC16-048-230 TXV 47,000 16.00 12.00 CX34-620 EL296UH110XV48C 6685333 XC16-048-230 TXV 47,500 16.00 12.00 CX34-620 EL296UH110XV60C 6685335 X016-048-230 TXV 47,500 16.50 12.20 CX34-620 SL280UH090V60C 6685154 XC16-048-230 TXV 47,000 16.00 12.00 CX34-62C SL280UH090XV60C 6685431 XC16-048-230 TXV 47,000 16.00 12.00 CX34-620 SL280UH110V60C 6685337 XC16-048-230 TXV 47,000 16.00 12.00 0X34-62C SL280UH110XV60C 6685434 XC16-048-230 TXV 47,000 16.00 12.00 0X34-620 SL0185B124/141V60 7110173 XC16-048-230 TXV 47,000 16.00 12.00 0X34-620 SL0185UF124/141V60 7110176 XC16-048-230 TXV 47,000 16.00 12.00 CX34-62C SLP98UH090XV48C 6685339 XC16-048-230 TXV 47,000 16.00 12.00 0X34-62C SLP98UH090XV60C 6685341 XC16-048-230 TXV 47,500 16.00 12.00 0X34-620 SLP98UH110XV60C 6685343 XC16-048-230 TXV 46,500 14.50 11.70 0X34-62D 6685146 XC16-048-230 TXV 47,000 16.00 12.00 0X34-62D EL296UH135XV6OD 6685345 XC16-048-230 TXV 47,000 16.00 12.00 0X34-62D SL280UH135V6OD 6685347 XC16-048-230 TXV 46,500 15.50 12.20 0X34-62D SL0185B124/141V60 7110178 X016-048-230 TXV 46,500 15.50 12.20 0X34-62D SL0185UF124/141V60 7110179 XC16-048-230 TXV 47,000 16.00 12.00 CX34-62D SLP98UH135XV6OD 6685349 X016-060-230 TXV 56,500 14.00 11.00 033-49 6564016 XC16-060-230 TXV 56,500 15.00 12.00 C33-49 EL180UH090E60C 6564114 X016-060-230 TXV 56,500 15.00 12.00 033-49 EL180UH110E60C 6564117 XC16-060-230 TXV 56,500 15.00 12.00 C33-49 EL195UH110XE60C 6564018 X016-060-230 TXV 56,500 15.00 11.00 033-49 EL296UH090XV60C 6564020 XC16-060-230 TXV 56,500 15.00 12.00 C33-49 EL296UH110XE60C 6564118 XC16-060-230 TXV 56,000 15.00 11.00 033-49 EL296UH110XVE60C 6564022 XC16-060-230 TXV 56,500 15.00 11.70 C33-49 SL280UH090V60C 6564031 XC16-060-230 TXV 56,500 15.00 11.70 033-49 SL280UH090XV60C 6564120 XC16-060-230 TXV 56,500 15.00 11.70 033-49 SL280UH110V60C 6564032 XC16-060-230 TXV 56,500 15.00 11.70 033-49 SL280UH110XV60C 6564122 XC16-060-230 TXV 56,500 15.00 11.00 033-49 SLP98UH090XV60C 6564034 XC16-060-230 TXV 56,000 15.00 11.00 033-49 SLP98UH110XV60C 6564036 XC16-060-230 TXV 55,000 14.00 11.00 033-50/600 6564038 XC16-060-230 TXV 54,000 14.50 11.00 033-50/600 CBWMV-600-120 6564124 XC16-060-230 TXV 55,000 15.00 11.70 033-50/600 EL180UH090E60C 6564127 XC16-060-230 TXV 55,000 14.50 11.70 033-50/600 EL180UH110E60C 6564128 XC16-060-230 TXV 55,000 14.50 11.70 033-50/600 EL180UH110XE60C 6564130 XC16-060-230 TXV 55,000 15.00 11.70 033-50/600 EL195UH110XE60C 6564040 X016-060-230 TXV 55,000 14.50 11.00 033-50/600 EL296UH090XV60C 6564042 X016-060-230 TXV 55,000 15.00 11.70 033-50/600 EL296UH110XE60C 6564131 XC16-060-230 TXV 55,000 14.50 11.00 033-50/600 EL296UH110XV60C 6564044 X016-060-230 TXV 55,000 15.00 11.00 033-50/600 SL280UH090V60C 6564052 XC16-060-230 TXV 55,000 14.50 11.00 033-50/600 SL280UH090XV60C 6564132 XC16-060-230 TXV 55,000 14.50 11.00 033-50/600 SL280UH110V60C 6564054 XC16-060-230 TXV 54,500 14.50 11.00 033-50/600 SL280UH110XV60C 6564135 XC16-060-230 TXV 55,000 14.50 11.00 033-50/600 SLP98UH090XV60C 6564056 XC16-060-230 TXV 55,000 14.50 11.00 033-50/600 SLP98UH110XV60C 6564058 X016-060-230 TXV 56,000 14.00 11.00 033-60D Ratings AHRI Certified to AHRI Standard 210/240(with 25 ft.of connecting refrigerant lines);95°F outdoor air temperature,80°F db/67°F wb entering@ __ IVE All ratings include the use of a blower time delay relay(TDR).All Lennox variable-speed furnaces and Air Handlers have time delay capabilities.Other Furnaces and Air Handlers may require an optional time delay relay(58M81)for field installation.See furnace or air handler specifications to determine if relay is needed. 10/0 9/1 8 Also see Expansion Valve Kit Usage Table. XC16-2 to 5 Ton Air Conditioner /Page 32 ASPEN BUILDING DEPARTMENT AHRI SYSTEM MATCHES NOTE- For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model Expansion Coil or AHRI No. Device Capacity SEER EER Air Handler Furnace Reference XC16-060-230 TXV 56,500 15.50 11.70 033-60D EL180UH135E6OD 6564139 X016-060-230 TXV 56,500 15.00 11.70 033-60D EL195UH135XE6OD 6564062 X016-060-230 TXV 56,500 15.00 11.70 033-60D EL296UH135XE6OD 6564141 X016-060-230 TXV 56,500 15.00 11.70 033-60D EL296UH135XV6OD 6564064 X016-060-230 TXV 56,500 15.50 11.70 033-60D SL280UH135V6OD 6564070 X016-060-230 TXV 56,000 15.00 11.00 033-60D SL0185B124/141V60 7110091 XC16-060-230 TXV 56,500 15.50 11.70 033-60D SLP98UH135XV6OD 6564072 X016-060-230 TXV 57,500 14.50 11.70 C33-620 6564074 XC16-060-230 TXV 57,500 15.50 12.20 033-620 EL180UH090E60C 6564144 X016-060-230 TXV 57,500 15.50 12.20 033-620 EL180UH110E60C 6564147 XC16-060-230 TXV 57,500 15.50 12.20 033-620 EL195UH110XE60C 6564076 X016-060-230 TXV 57,500 15.50 11.70 033-620 EL296UH090XV60C 6564077 XC16-060-230 TXV 57,500 15.50 12.20 033-620 EL296UH110XE60C 6564149 XC16-060-230 TXV 57,000 15.50 11.70 033-620 EL296UH110XV60C 6564078 XC16-060-230 TXV 57,500 16.00 12.00 C33-620 SL280UH090V60C 6563960 X016-060-230 TXV 57,500 15.50 12.00 033-620 SL280UH090XV60C 6564150 XC16-060-230 TXV 57,500 15.50 11.70 033-620 SL280UH110V60C 6564086 X016-060-230 TXV 57,500 15.00 11.70 033-620 SL280UH110XV60C 6564152 XC16-060-230 TXV 57,000 15.00 11.50 033-620 SL0185B124/141V60 7110182 X016-060-230 TXV 57,000 15.00 12.00 033-620 SL0185UF124/141V60 7110088 X016-060-230 TXV 57,500 15.50 11.70 033-620 SLP98UH090XV60C 6564088 X016-060-230 TXV 57,000 15.50 11.70 033-620 SLP98UH110XV60C 6564090 XC16-060-230 TXV 56,500 14.00 11.00 033-62D 6564092 X016-060-230 TXV 57,000 15.50 12.00 033-62D EL180UH135E6OD 6564153 XC16-060-230 TXV 57,000 15.00 11.70 033-62D EL195UH135XE6OD 6564094 X016-060-230 TXV 57,000 15.00 11.70 033-62D EL296UH135XE6OD 6564155 X016-060-230 TXV 57,000 15.50 11.70 033-62D EL296UH135XV6OD 6564096 X016-060-230 TXV 57,000 15.50 12.00 033-62D SL280UH135V6OD 6564102 X016-060-230 TXV 57,000 15.00 11.50 033-62D SL0185B124/141V60 7110089 X016-060-230 TXV 56,000 15.00 11.00 033-62D SL0185UF124/141V60 7110086 X016-060-230 TXV 57,000 15.50 12.00 033-62D SLP98UH135XV6OD 6564104 X016-060-230 TXV 56,500 14.50 11.70 CBX25UH-060 6564156 X016-060-230 TXV 56,500 16.00 12.00 CBX25UHV-060 6970140 X016-060-230 TXV 56,500 15.50 12.00 CBX27UH-060 6563962 X016-060-230 TXV 56,500 14.50 11.70 CBX32M-060 6563963 X016-060-230 TXV 56,000 15.50 11.70 CBX32MV-048 6563964 X016-060-230 TXV 56,500 15.50 11.70 CBX32MV-060 6563965 XC16-060-230 TXV 56,500 15.50 12.20 CBX32MV-068 6563966 X016-060-230 TXV 55,000 15.00 11.70 CBX4OUHV-048 6564157 X016-060-230 TXV 55,500 15.00 11.70 CBX4OUHV-060 6564158 X016-060-230 TXV 53,000 13.00 11.00 0H23-51 6564159 X016-060-230 TXV 54,000 13.00 11.00 0H23-65 6563967 X016-060-230 TXV 54,000 14.50 11.00 0H23-65 EL180UH090E60C 6564160 X016-060-230 TXV 54,000 14.50 11.00 0H23-65 EL180UH110E60C 6564161 XC16-060-230 TXV 54,000 14.50 11.00 0H23-65 EL195UH110XE60C 6563968 X016-060-230 TXV 54,000 14.50 11.00 0H23-65 EL296UH090XV60C 6563969 XC16 060 230 TXV 54,000 14.50 11.00 CH23 65 EL296UH110XE".�♦♦ � `� Ratings AHRI Certified to AHRI Standard 210/240(with 25 ft.of connecting refrigerant lines);95°F outdoor air temperature,80°F db/67°F wb`yz!7'•• � r L) All ratings include the use of a blower time delay relay(TDR).All Lennox variable-speed furnaces and Air Handlers have time delay capabilities.Other Furnaces and Air Handlers may require an optional time delay relay(58M81)for field installation.See furnace or air handler specifications to determine if relay is need/.0/0 9/1 8 Also see Expansion Valve Kit Usage Table. XC1ti-2to5 Ton Air6qn�{� ,1�. ,$ENT AHRI SYSTEM MATCHES NOTE-For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model Expansion Coil or AHRI No. Device Capacity SEER EER Air Handler Furnace Reference XC16-060-230 TXV 54,000 14.50 11.00 0H23-65 EL296UH110XV60C 6563970 XC16-060-230 TXV 54,500 15.00 11.00 CH23-65 EL296UH135XV6OD 6563971 XC16-060-230 TXV 54,500 15.00 11.00 CH23-65 SL280UH090V60C 6563974 XC16-060-230 TXV 54,000 14.50 11.00 CH23-65 SL280UH110XV60C 6563975 XC16-060-230 TXV 54,500 15.00 11.00 CH23-65 SL280UH135XV6OD 6563976 XC16-060-230 TXV 54,000 14.50 11.00 CH23-65 SLP98UH090XV60C 6563977 XC16-060-230 TXV 54,000 14.50 11.00 0H23-65 SLP98UH110XV60C 6563978 XC16-060-230 TXV 54,500 15.00 11.00 0H23-65 SLP98UH135XV6OD 6563979 XC16-060-230 TXV 57,500 14.50 11.70 0H23-68 6563980 XC16-060-230 TXV 54,500 15.00 11.00 CH23-68 EL180UH135E6OD 6564164 XC16-060-230 TXV 57,000 15.00 11.70 0H23-68 EL195UH135XE6OD 6563981 XC16-060-230 TXV 54,500 14.50 11.00 0H23-68 EL296UH135XE6OD 6564163 XC16-060-230 TXV 57,500 15.50 12.00 0H23-68 EL296UH135XV6OD 6563982 XC16-060-230 TXV 57,500 15.50 12.00 0H23-68 SL280UH135V6OD 6563984 XC16-060-230 TXV 57,000 15.50 12.00 0H23-68 SLP98UH135XV6OD 6563985 XC16-060-230 TXV 56,000 14.00 11.00 0H33-50/60C 6563986 XC16-060-230 TXV 56,000 15.00 11.00 0H33-50/60C 6563987 XC16-060-230 TXV 56,000 15.00 11.70 CH33-50/60C EL180UH090E60C 6564167 XC16-060-230 TXV 56,000 15.00 11.70 0H33-50/600 EL180UH110E60C 6564168 XC16-060-230 TXV 56,000 15.00 11.70 0H33-50/60C EL180UH110XE60C 6564169 XC16-060-230 TXV 56,000 15.00 11.70 0H33-50/600 EL195UH110XE60C 6563988 XC16-060-230 TXV 56,000 15.00 11.00 CH33-50/600 EL296UH090XV60C 6563989 XC16-060-230 TXV 56,000 15.00 11.70 0H33-50/600 EL296UH110XE60C 6564170 XC16-060-230 TXV 56,000 15.00 11.00 CH33-50/600 EL296UH110XV60C 6563990 XC16-060-230 TXV 56,000 15.00 11.00 0H33-50/600 SL280UH090V60C 6563993 XC16-060-230 TXV 56,000 15.00 11.00 CH33-50/60C SL280UH090XV60C 6564166 XC16-060-230 TXV 56,000 14.50 11.00 CH33-50/600 SL280UH110V60C 6563994 XC16-060-230 TXV 55,500 15.00 11.70 CH33-50/60C SL280UH110XV60C 6564165 XC16-060-230 TXV 56,000 15.00 11.00 CH33-50/60C SLP98UH090XV60C 6563995 XC16-060-230 TXV 56,000 15.00 11.00 CH33-50/60C SLP98UH110XV60C 6563996 XC16-060-230 TXV 55,500 14.00 11.00 CH33-60D 6563997 XC16-060-230 TXV 56,000 15.00 11.70 CH33-60D CBWMV-600-100 6563998 XC16-060-230 TXV 56,000 15.00 11.00 CH33-60D EL195UH135XE6OD 6563999 XC16-060-230 TXV 56,000 15.00 11.70 CH33-60D EL296UH135XV6OD 6564000 XC16-060-230 TXV 56,000 15.00 11.70 CH33-60D SL280UH135V6OD 6564002 XC16-060-230 TXV 56,000 15.50 11.70 CH33-60D SLP98UH135XV6OD 6564003 XC16-060-230 TXV 56,000 14.00 11.00 CH33-62D 6564004 XC16-060-230 TXV 56,500 15.50 11.70 0H33-62D EL180UH135E6OD 6564172 XC16-060-230 TXV 56,500 15.00 11.70 0H33-62D EL195UH135XE6OD 6564005 XC16-060-230 TXV 56,500 15.00 11.70 0H33-62D EL296UH135XE6OD 6564171 XC16-060-230 TXV 56,500 15.00 11.70 0H33-62D EL296UH135XV6OD 6564006 XC16-060-230 TXV 56,000 15.00 12.00 0H33-62D SL280UH090V60C 6564008 XC16-060-230 TXV 56,500 15.50 11.70 0H33-62D SL280UH090XV60C 6564173 XC16-060-230 TXV 56,000 15.00 12.00 0H33-62D SL280UH110V60C 6564009 XC16-060-230 TXV 56,500 15.50 11.70 0H33-62D SL280UH135V6OD 6564010 XC16-060-230 TXV 56,500 15.50 11.70 CH33-62D SLP98UH135XV6OD 6564011 XC16-060-230 TXV 56,500 14.50 11.50 CH35-51C . Ratings AHRI Certified to AHRI Standard 210/240(with 25 ft.of connecting refrigerant lines);95°F outdoor air temperature,80°F db/67°F wb entering @ ., '•�. !'� �VE All ratings include the use of a blower time delay relay(TDR).All Lennox variable-speed furnaces and Air Handlers have time delay capabilities.Other Furnaces and Air Handlers may require an optional time delay relay(58M81)for field installation.See furnace or air handler specifications to determine if relay is needed. 10/0 9/1 8 Also see Expansion Valve Kit Usage Table. XC16-2 to 5 Ton Air Conditioner /Page 34 ASPEN BUILDING DEPARTMENT AHRI SYSTEM MATCHES NOTE- For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model Expansion Coil or AHRI No. Device Capacity SEER EER Air Handler Furnace Reference XC16-060-230 TXV 57,000 15.50 12.00 0H35-510 CBWMV-60C-100 7165650 XC16-060-230 TXV 56,500 15.00 11.50 0H35-510 CBWMV-600-120 7165626 XC16-060-230 TXV 57,000 15.50 12.00 0H35-510 EL180UH090E60C 7165627 XC16-060-230 TXV 56,500 15.25 12.00 0H35-510 EL180UH110E60C 7165628 XC16-060-230 TXV 56,500 15.25 12.00 0H35-510 EL180UH110XE60C 7165629 XC16-060-230 TXV 56,500 15.25 12.00 CH35-51C EL195UH110XE60C 7165630 XC16-060-230 TXV 56,500 15.00 11.00 0H35-510 EL296UH090XV60C 7165631 XC16-060-230 TXV 56,500 15.25 12.00 0H35-510 EL296UH110XE60C 7165633 XC16-060-230 TXV 56,500 15.25 11.50 0H35-510 EL296UH110XV60C 7165632 XC16-060-230 TXV 57,000 15.25 11.70 0H35-510 SL280UH090V60C 7165634 XC16-060-230 TXV 57,000 15.75 12.00 0H35-51C SL280UH090XV60C 7165635 XC16-060-230 TXV 56,500 15.00 11.50 0H35-510 SL280UH110V60C 7165636 XC16-060-230 TXV 56,000 15.25 11.70 0H35-51C SL280UH110XV60C 7165637 XC16-060-230 TXV 56,500 15.25 11.00 0H35-510 SLP98UH090XV60C 7165638 XC16-060-230 TXV 56,500 15.25 11.50 CH35-510 SLP98UH110XV60C 7165639 XC16-060-230 TXV 56,000 14.25 11.50 0H35-60D 7165640 XC16-060-230 TXV 56,500 15.50 11.70 CH35-60D EL180UH135E6OD 7165641 XC16-060-230 TXV 56,500 15.00 11.70 0H35-60D EL195UH135XE6OD 7165642 XC16-060-230 TXV 56,500 15.00 11.70 0H35-60D EL296UH135XE6OD 7165644 XC16-060-230 TXV 56,500 15.50 11.70 0H35-60D EL296UH135XV6OD 7165643 XC16-060-230 TXV 56,500 15.50 11.70 0H35-60D SL280UH135V6OD 7165645 XC16-060-230 TXV 56,500 15.50 11.70 0H35-60D SLP98UH135XV6OD 7165646 XC16-060-230 TXV 54,000 14.50 11.00 0R33-50/60 SLP98DF090XV60C 6564174 XC16-060-230 TXV 54,000 14.50 11.00 0R33-50/60 SLP98DF110XV60C 6564176 XC16-060-230 TXV 55,000 14.00 11.00 0R33-60 6564012 XC16-060-230 TXV 54,500 14.50 11.50 0R33-60 EL195DF110XE60C 6800915 XC16-060-230 TXV 54,500 14.50 11.00 0R33-60 EL296DF090XV60C 6564013 XC16-060-230 TXV 54,500 14.50 11.00 CR33-60 EL296DF110XV60C 6564014 XC16-060-230 TXV 54,000 14.50 11.00 0R33-60 SLP98DF090XV60C 6564175 XC16-060-230 TXV 54,000 14.50 11.00 0R33-60 SLP98DF110XV60C 6564177 XC16-060-230 TXV 56,500 14.00 11.00 0X34-49 6564015 XC16-060-230 TXV 56,500 15.00 12.00 0X34-49 EL180UH090E60C 6564115 XC16-060-230 TXV 56,500 15.00 12.00 0X34-49 EL180UH110XE60C 6564116 XC16-060-230 TXV 56,500 15.00 12.00 0X34-49 EL195UH110XE60C 6564017 XC16-060-230 TXV 56,500 15.00 11.70 0X34-49 SL280UH090V60C 6564029 XC16-060-230 TXV 56,500 15.00 11.70 CX34-49 SL280UH090XV60C 6564121 XC16-060-230 TXV 56,500 15.00 11.70 0X34-49 SL280UH110V60C 6564030 XC16-060-230 TXV 56,500 15.00 11.70 0X34-49 SL280UH110XV60C 6564123 XC16-060-230 TXV 56,500 15.00 11.00 0X34-49 SLP98UH090XV60C 6564033 XC16-060-230 TXV 56,000 15.00 11.00 0X34-49 SLP98UH110XV60C 6564035 XC16-060-230 TXV 55,000 14.00 11.00 0X34-50/600 6564037 XC16-060-230 TXV 54,000 14.50 11.00 0X34-50/600 CBWMV-60C-120 6564125 XC16-060-230 TXV 55,000 15.00 11.70 0X34-50/60C EL180UH090E60C 6564126 XC16-060-230 TXV 55,000 14.50 11.70 0X34-50/600 EL180UH110E60C 6564129 XC16-060-230 TXV 55,000 15.00 11.70 0X34-50/60C EL195UH110XE60C 6564039 XC16-060-230 TXV 55,000 14.50 11.00 0X34-50/600 EL296UH090XV60C 6564041 XC16-060-230 TXV 56,500 15.00 12.00 CX34-50/60C EL296UH110XE".��♦ VEL, Ratings AHRI Certified to AHRI Standard 210/240(with 25 ft.of connecting refrigerant lines);95°F outdoor air temperature,80°F db/67°F wb`y!7'••y�. i) All ratings include the use of a blower time delay relay(TDR).All Lennox variable-speed furnaces and Air Handlers have time delay capabilities.Other Furnaces and Air Handlers may require an optional time delay relay(58M81)for field installation.See furnace or air handler specifications to determine if relay is need.".O/O 9/1 8 Also see Expansion Valve Kit Usage Table. XC16-2 to 5 Ton Air6qn�{� ,1�. ,$ENT AHRI SYSTEM MATCHES NOTE-For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model Expansion Coil or AHRI No. Device Capacity SEER EER Air Handler Furnace Reference XC16-060-230 TXV 55,000 14.50 11.00 0X34-50/60C EL296UH110XV60C 6564043 XC16-060-230 TXV 55,000 15.00 11.00 CX34-50/60C SL280UH090V60C 6564051 XC16-060-230 TXV 55,000 14.50 11.00 CX34-50/60C SL280UH090XV60C 6564133 XC16-060-230 TXV 55,000 14.50 11.00 CX34-50/60C SL280UH110V60C 6564053 XC16-060-230 TXV 54,500 14.50 11.00 CX34-50/60C SL280UH110XV60C 6564134 XC16-060-230 TXV 55,000 14.50 11.00 CX34-50/60C SLP98UH090XV60C 6564055 XC16-060-230 TXV 55,000 14.50 11.00 0X34-50/60C SLP98UH110XV60C 6564057 XC16-060-230 TXV 56,000 14.00 11.00 0X34-60D 6564059 XC16-060-230 TXV 56,500 15.50 11.70 0X34-60D EL180UH135E6OD 6564138 XC16-060-230 TXV 56,500 15.00 11.70 CX34-60D EL195UH135XE6OD 6564061 XC16-060-230 TXV 56,500 15.00 11.70 0X34-60D EL296UH135XV6OD 6564063 XC16-060-230 TXV 56,500 15.50 11.70 0X34-60D SL280UH135V6OD 6564069 XC16-060-230 TXV 56,000 15.00 11.00 0X34-60D SL0185B124/141V60 7110090 XC16-060-230 TXV 56,500 15.50 11.70 0X34-60D SLP98UH135XV6OD 6564071 XC16-060-230 TXV 57,500 14.50 11.70 0X34-620 6564073 XC16-060-230 TXV 57,500 15.50 12.20 0X34-620 EL180UH090E60C 6564143 XC16-060-230 TXV 57,500 15.50 12.20 0X34-620 EL180UH110E60C 6564145 XC16-060-230 TXV 57,500 15.50 12.20 CX34-62C EL195UH110XE60C 6564075 XC16-060-230 TXV 56,500 15.00 11.00 0X34-620 EL296UH090XV60C 6564019 XC16-060-230 TXV 57,500 15.50 12.20 0X34-62C EL296UH110XE60C 6564148 XC16-060-230 TXV 56,000 15.00 11.00 0X34-620 EL296UH110XV60C 6564021 XC16-060-230 TXV 57,500 16.00 12.00 CX34-62C SL280UH090V60C 6563959 XC16-060-230 TXV 57,500 15.50 12.00 0X34-62C SL280UH090XV60C 6564151 XC16-060-230 TXV 57,500 15.50 11.70 CX34-62C SL280UH110V60C 6564085 XC16-060-230 TXV 57,500 15.50 12.20 0X34-62C SL280UH110XV60C 6564146 XC16-060-230 TXV 57,000 15.00 12.00 CX34-62C SL0185UF124/141V60 7110087 XC16-060-230 TXV 57,500 15.50 11.70 CX34-62C SLP98UH090XV60C 6564087 XC16-060-230 TXV 57,000 15.50 11.70 CX34-62C SLP98UH110XV60C 6564089 XC16-060-230 TXV 56,500 14.00 11.00 CX34-62D 6564091 XC16-060-230 TXV 57,000 15.50 12.00 CX34-62D EL180UH135E6OD 6564154 XC16-060-230 TXV 57,000 15.00 11.70 CX34-62D EL195UH135XE6OD 6564093 XC16-060-230 TXV 56,500 15.00 11.70 CX34-62D EL296UH135XE6OD 6564140 XC16-060-230 TXV 57,000 15.50 11.70 CX34-62D EL296UH135XV6OD 6564095 XC16-060-230 TXV 57,000 15.50 12.00 CX34-62D SL280UH135V6OD 6564101 XC16-060-230 TXV 57,000 15.00 11.50 CX34-62D SL0185B124/141V60 7110092 XC16-060-230 TXV 56,000 15.00 11.00 CX34-62D SL0185UF124/141V60 7110085 XC16-060-230 TXV 57,000 15.50 12.00 CX34-62D SLP98UH135XV6OD 6564103 Ratings AHRI Certified to AHRI Standard 210/240(with 25 ft.of connecting refrigerant lines);95°F outdoor air temperature,80°F db/67°F wb entering evaporator air. All ratings include the use of a blower time delay relay(TDR).All Lennox variable-speed furnaces and Air Handlers have time delay capabilities.Other Furnaces and Air Handlers may require an optional time delay relay(58M81)for field installation.See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. RECEIVED 10/09/18 XC16-2 to 5 Ton Air Conditioner /Page 36 ASPEN BUILDING DEPARTMENT RECEIVED 10/09/18 ASPEN BUILDING DEPARTMENT RECEIVED 10/09/18 ASPEN BUILDING DEPARTMENT RECEIVED 10/09/18 ASPEN BUILDING DEPARTMENT REVISIONS Sections Description of Change AHRI System Matches Updated. ti..l CERTIFIED TM www.ahridirectory.org O cm Unitary Small AC 040 MIMI AHRI Standard 210/240 Ce,siticxtisn applies only when the complete system /MEMBER COMPANY C US Is listed with AHRI. Intertek Visit us at www.lennox.com J For the latest technical information,www.lennoxdavenet.com Contact us at 1-800-4-LENNOX RECEIVED NOTE-Due to Lennox'ongoing commitment to quality,Specifications,Ratings and Dimensions subject to change without notice and without incurring liability.10/0 9/1 8 Improper installation,adjustment,alteration,service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency. ©2014 Lennox Industries,Inc. ASPEN BUILDING DEPARTMENT LENNOX) INSTALLATION ©2013 Lennox Industries Inc. INSTRUCTIONS Dallas,Texas,USA CBWMV Series Units AIR HANDLERS Technical i 505,047M llll Publications / 12/2013 Litho U.S.A. Supersedes)/2013 � Table of Contents Introduction 1 Shipping and Packing List 1 CBWMV Unit Dimensions 2 General 3 CBWMV Unit Parts Arrangement 3 CBWMV Unit Parts Description 3 .1 t CBWMV Unit Optional Accessories 3 Requirements 3 Ito i IAApplication 4 Installation - Setting Equipment 4 _ Duct System 5 Return Air Opening Guidelines 5 Filter Assembly & Filters 6 Plumbing 7 Electrical 7 Freeze-stat Operation 11 BDC3 Variable Blower Control Board 11 Blower Speed Adjustments 11 Initial Air System Purging 14 System Adjustments 14 THIS MANUAL MUST BE LEFT WITH THE Annual Service 14 HOMEOWNER FOR FUTURE REFERENCE Service Filters 14 Winterizing the CBWMV Unit 14 AWARNING Repair Parts List 14 Troubleshooting: Improper installation, adjustment, alteration, service or Continuous Fan Sequence of Operation 15 maintenance can cause property damage, personal inju- Heating Sequence of Operation 15 ry or loss of life. Cooling Sequence of Operation 16 Installation and service must be performed by a licensed Shipping and Packing List professional installer(or equivalent) or service agency. 1 - CBWMV Air Handler [NOTE - Includes freezestat mounted to the manifold.] AWARN I N G 1 - Bag assembly containing: The State of California has determined that this product 1 - Electrical make-up box may contain or produce a chemical or chemicals, in very 1 - Copper fitting low doses, which may cause serious illness or death. It 1 - Snap bushing may also cause cancer, birth defects, or reproductive 2 - Water line grommets harm. 3 - Wire nuts 2-7/8" cabinet plugs Check equipment for shipping damage. If you find any Introduction damage, immediately contact the last carrier. The CBWMV air handler/hot water coil unit is designed to A CAUTION be used with non-potable boiler systems for warm air heat- ing. A variety of Lennox air conditioning systems may be Unit is designed to be used with non-potable boiler sys- applied to the CBWMV unit for optional cooling. tems only. 12/2013 Page 1 5°5,(41 0 9/18 11111011111111010110110111111100111111110111111110011 � ii BUILDING DEPARTMENT CBWMV Unit Dimensions - inches (mm) *NOTE - Single side inlet applications result in approximately 4 percent reduction of CFM on B-size units and approximately WATER INLET 5 percent reduction of CFM on C-size units. pill,. SUPPLY AIR OPENING F WATER OUTLET D 23-3/4(603) OPTIONAL EXTERNAL SIDE RETURN 25(635) AIR FILTER KIT(Either Side)-Not for TOP VIEW use with optional Return Air Base. 28-1/2 A ► (724) B ► f 9/16 19-7/16 9/16 (14) ALTERNATE WATER I (494) (14) INLET(far side) 1 I o 0 1 A 1-1/4"(32) - ) 1-3/4"(44) - 10-1/2" (267) OPTIONAL ALTERNATE EXTERNAL WATER OUTLET SIDE RETURN AIR FILTER KIT 2 ELECTRICAL INLET (Either Side) (51) (Either Side) 40 =O (1016) /1—f 111.1 14-3/4 4 I 23 (375) 16 (102) (584) Jr *OPTIONAL 14 (406) RETURN CUTOUT (356) (Either Side) AIR FLOW i J 11-15/16(49) C 16 23-1/2 J *Bottom Return hil- 4 ( ) (597) II 4 4-1/4 3/4(19) Air Opening 3/4(19) (108 *Bottom Return Air Opening FRONT VIEW ) SIDE VIEW CBWMV Model No. A B C D E F G -24B-040 17-1/2(445) 16-3/8(416) 16 (406) 1-1/2 (38) 1-3/4(44) 8(203) 2 (51) -36B-070 -36C-090 -60C-100 21 (533) 19-7/8(454) 19-1/2 (495) 2 (51) 2-1/2 (64) 9-1/2(241) 1-1/2 (38) -60C-120 RECEIVED Page 2 10/09/18 505,547M ASPEN BUILDING DEPARTMENT General CBWMV Unit Optional Accessories These instructions are intended as a general guide and do Refer to the CBWMV Product specification (EHB) for a not supersede local codes in any way. Consult authorities current list of available accessories. having jurisdiction before installation. Only qualified ser- vice technicians or installers may install and service this Requirements unit. CBWMV Unit Parts Arrangement A WARNING Improper installation, adjustment, alteration, service or CBWMV Unit maintenance can cause personal injury, loss of life, or HOT WATER INSULATED damage to property. COPPER STEEL Installation and service must be performed by a qualified TUBE COIL CABINET installer or service agency. Installation of Lennox CBWMV unit must conform with lo- ...\.<7;.____, ______ cal building codes. Refer to the electrical section (Page 7) for US and Canadian electrical regulations. // When paired with a water heating device, refer to local building codes for special considerations. Refer to water 1/7 % heating device for agency and service clearances. Clear- �� ances to combustibles for the CBWMV unit only is zero %„ inches on all sides. Table 1 lists recommended service // "" clearances. '� Table 1 CBWMV Unit Service Clearances Clearances Location Inches(mm) vi ��I ( , i � � Recommended Front Access 30(762) +;,i �� Service Access Panel \'. NOTE- Service access clearance must be maintained. / Accessibility and service clearances must take prece- SUPPLY AIR dence over fire protection clearances. CBWMV L7 BLOWER For installation in a residential garage, unit must be lo- CONTROL BOX cated or protected to avoid physical damage by vehicles. Figure 1 The CBWMV unit must be installed so that its electrical components are protected from water. CBWMV Unit Parts Description When the CBWMV unit is used with an air conditioner, the Blower air handler shall be installed on the upstream side of the The CBWMV is equipped with a variable speed motor that cooling evaporator coil to avoid freeze-up of water system provides separate cooling and heating CFM selections and condensation. With a parallel flow arrangement, a and low continuous fan speeds. damper(or other means to control the flow of air)must ad- equately prevent chilled air from entering the air handler. If Hot Water Coil the damper is manually operated, it must be equipped to The copper tube coil is equipped with aluminum fins which prevent operation of either the heating or the cooling unit, provide excellent heat transfer. Manual air bleed ports are unless it is in the full HEAT or COOL setting. located in the copper tubing to release trapped air in the NOTE-CBWMV series units must not be used in or for the water circuit in all unit configurations. following applications: Blower Control • construction heater-during any phase of construction The control provides a fixed blower delay of 45 seconds ON /30 seconds OFF on a W call. • unit heater Thermostat and accessory connections are made to the • mobile home heater terminal strips in the control box. • potable water applications RECEIVED Page 3 10/09/18 cAw,f mEs BUILDING DEPARTMENT Application CBWMV Multi-Positional Unit The CBWMV unit is designed for use in non-potable water /'/ boiler systems. The water heating device must be ade- / AIIR quate to provide enough heat according to the Product ;/% , �' Specification bulletin. The water heating device must pro- / FLOW _ �\\ vide a minimum of 6 gallons/minute for small units (CBW- MV-040, -070) and 9 gallons/minute for large units (CBW- RIGHT HAND DISCHARGE` MV-090, -100, -120). I AIR I I LOW Installation - Setting Equipment I AIR FLOW UPFLOW 1 AWARNING DOWNFLOW BASE This product contains fiberglass wool. \ FLOW ♦ AIR /\ i Disturbing the insulation during installation, mainte- /'/ 1-1 nance, or repair will expose you to fiberglass wool dust. Breathing this may cause lung cancer. (Fiberglass wool , IIIIIUM LEFT HAND DISCHARGE* is known to the State of California to cause cancer.) DOWNFLOW Fiberglass wool may also cause respiratory, skin, and *CBWMV units must not be installed horizontally on the front or eye irritation. back of the unit. To reduce exposure to this substance or for further infor- Figure 2 mation, consult material safety data sheets available Units may be horizontally installed in either attic or crawl from address shown below, or contact your supervisor. space. Lennox Industries Inc. P.O. Box 799900 A CAUTION Dallas, TX 75379-9900 CBWMV series units are shipped with an antifreezether- The boiler installation must conform to the requirements of mostat to prevent the water coil from freezing. The the authority having jurisdiction or, in the absence of such freeze stat is installed at the factory but must be field requirements, to the latest revision of the National Fuel wired (see figures 12 and 13). Do not bypass this feature Gas Code, ANSI Z223. (Available from the American Gas when you install or run the unit. Association, 8501 E. Pleasant Valley Road, Cleveland, OH 44134). Reference should also be made to local gas A CAUTION utility regulations and other codes in effect in the same area in which the installation is to be made. When installed Use a drain pan for installations over finished living in Canada: The latest revision of the CAN1/CSA-B149.1 and/or B149.2 Installation Codes for Gas-Burning Equip- areas. ment and/or local codes. Either suspend the unit from the roof rafters or floor joists Determine the CBWMV unit installation location and posi- or mount on a platform. The CBWMV unit must be level tion units so that door panels are accessible. Keep in mind and well supported. routing of the water and plumbing lines and electrical con- NOTE- 1/2 hp and 1 hp blower motors are equipped with nections. three flexible legs and one rigid leg. The rigid leg is The CBWMV unit is multi-positional. No adjustment is nec- equipped with a shipping bolt and a flat white plastic wash- essary to apply unit for upflow or horizontal discharge. er(rather than the rubber mounting grommet used with a Downflow applications with add-on cooling coils require flexible mounting leg). The bolt and washer must be re- field-fabricated transitions that provide at least 6 inches of moved before the air handler is placed into operation. clearance for the CBWMV unit's inlet/outlet water lines. After the bolt and washer have been removed, the rigid leg See figure 2 for examples. will not touch the blower housing. RECEIVED Page 4 10/09/18 505,547M ASPEN BUILDING DEPARTMENT Duct System Side Return Use industry-approved standards (such as those pub- For side return air applications, cut the air handler cabinet lished by Air Conditioning Contractors of America or Amer- at the maximum return air dimensions shown on page 2. See figure 3 for a typical side inlet arrangement with a tran- ican Society of Heating, Refrigerating and Air Conditioning sition and filter. Engineers)to size and install the supply and return air duct system. This will result in a quiet and low-static system that NOTE - Single side inlet applications result in approxi- has uniform air distribution. mately a 4 percent reduction of CFM on B-size units and NOTE - Do not operate the air handler with an external approximately a 5 percent reduction of CFM on C-size static pressure that exceeds 0.8 inches w.c. Higher exter- units: nal static pressures may cause erratic operation. Return Air Plenum Side Return Air With Transition And Filter A IMPORTANT Return air must not be drawn from a room where any fos- 20"X 25"X 1° sil fuel appliance (ie., a water heater) is installed. o (508MM X 635MM X 25MM) CLEANABLE FILTER When return air is drawn from a room, a negative pres- sure is created in the room. If a fossil fuel appliance is op- erating in a room with negative pressure, the flue prod- ucts can be pulled back down the vent pipe and into the RETURN AIR room. This reverse flow of the flue gas may result in in- PLENUM complete combustion and the formation of carbon mon- oxide gas. This toxic gas might then be distributed TRANSITION throughout the house by the air handler duct system. Return Air Opening Guidelines Figure 3 NOTE-Do not bring in air from the back of the unit. Return air can be brought in from the sides or bottom only. Return Air Base Bottom Return For return air with the optional return air base (RAB), see If the air handler is installed on a platform with bottom re- figure 4 (and refer to installation instructions provided with turn, make an airtight seal between the bottom of the air Return Air Base kit). handler and the platform to ensure that the air handler op- erates properly and safely. Use aluminum tape or mastic *NOTE- Both unit and return air base openings must be between the plenum and the air handler cabinet to ensure connected to and entirely covered by a single plenum or a tight seal. The air handler is equipped with a removable IAQ accessory opening. Optional side return air filter kits bottom panel to facilitate installation. cannot be used with RAB Return Air Base. Optional Return Air Base and Unit Dimensions - Inches (mm) 4 (102)- *23(584)Overall(Max.) 0 NOTE-IN SIDE RETURN APPLICATIONS, THE RAB *Minimum IS REQUIRED FOR 100% 11 (279) CFM CAPACITY. *Maximum *Height varies 14(356) with plenum or 'Unit IAQ accessory Side Return height. AIR FLOW Air Openings Opening (Either Side) \ RETURN 7-1/4 *Base 5-5/8 AIR BASE (184) Opening (143) 17(432)RAB-B(98M60) 23(584) 3/4 21 (533)RAB-C(98M58) 7/8(22)—M. 27-5/8(702) I (19) FRONT VIEW SIDE VIEW Figure 4 RECEIVED Page 5 10/09/18 C W,f mES BUILDING DEPARTMENT Removing the Bottom Panel (bottom return or return 2. Install one bolt and two nuts into each hole. Screw the air base configurations)—Remove the two screws that first nut onto a bolt and then insert the bolt into a hole. secure the bottom cap to the air handler. Pivot the bottom A flat washer may be added between the nut and the cap down to release the bottom panel. Once the bottom bottom of the unit. panel has been removed, reinstall the bottom cap. See fig- 3. Screw another nut onto the bolt on the inside of the air ure 5. handler base. A flat washer may be added between the nut and the bottom of the unit. Removing the Bottom Panel 4. Adjust the outside nut to the appropriate height and tighten the inside nut to secure the arrangement. Horizontal Applications The CBWMV air handler can be installed in horizontal ap- r plications. Refer to Product Specification bulletin for addi- 0 tional information. Allow for clearances to combustible ma- terials as indicated on the unit nameplate. This air handler may be installed in either an attic or a fig crawlspace. Either suspend the air handler from roof raf- ters or floor joists, as shown in figure 7. The unit must be �- \ supported at both ends and beneath the blower deck to /OTTOMCAP prevent sagging. SCREW \� — Unit Suspended in Attic or Crawlspace BOTTOM PANEL Figure 5 1/4IN. ---------------- RODS Leveling an Upflow Unit—When the side return air inlets are used in an upflow application, it may be necessary to ------------ install leveling bolts on the bottom of the air handler. Use DRAIN field-supplied corrosion-resistant 5/16 inch machine bolts = PAN ALLOW (4) and nuts (8). See figure 6. SUFFICIENT CLEARANCE NOTE- Maximum leveling bolt length is 1-1/2 inches. BETWEEN ROD AND UNIT TO REMOVE Leveling Bolt Installation ACCESS PANEL. 3/8(10) inches(mm) ANGLE IRON AIR HANDLER FRONT U-CHANNELS rill:_i 1-3/4(44) Figure 7 3/8(10) ff NOTE - Heavy-gauge, perforated sheet metal straps (plumbers'straps)may be used to suspend the unit from roof rafters or ceiling joists. When suspending the unit in this manner, support must be provided for both the ends 1-3/4(44) LING BOLT and the middle of the airhandler to prevent sagging. Straps CATIONS must not interfere with plenum or water piping. Securing screws should be 1/2 inch from the top edge and 1-1/2 inch LEVELING BOLT from the side edge in all cases.Cooling coils andsupply LOCATIONS3/8(10) and return air plen urns must be supported separately. -; NOTE- When the air handler is installed on a platform in a crawlspace, it must be elevated enough to avoid water 111--- Le damage and to allow the optional evaporator coil to drain. �0 Horizontal and Downflow Applications 3/8(10) 1------"ii 1-3/4(44) Return air can be brought in through the end of an air han- dler installed in the horizontal or downflow application.The 1-3/4(44) air handler is equipped with a removable bottom panel to Figure 6 facilitate installation (see figure 5). 1. Lay the air handler on its back and drill a 5/16 inch di- Filter Assembly & Filters ameter hole in each corner of the air handler's bottom. This unit is not equipped with a filter or rack. A field-pro- See figure 6 for the correct location of the holes. Drill vided high-velocity filter is required for the unit to operate through the bottom panel and the bottom flange of the properly. Table 2 lists recommended filt I cabinet. must be in place any time the unit is open ,.� � Page 6 10/09/18 505,547M ASPEN BUILDING DEPARTMENT Table 2 nections secured to the lower left coil manifold for left side Recommended Filter Sizes make-up box installations. For right side make-up box installations, remove the wire tie that holds the line voltage Air Handler Filter Size connections and pull excess wires into blower deck/control Cabinet Size Side Return Bottom Return box area as shown in figure 8. 17-1/2" 16 X 25 X 1 (1) 16 X 25 X 1 (1) Install make-up box (provided for line voltage wiring in the 21" 16 X 25 X 1 (1) 20 X 25 X 1 (1) unit's bag assembly) as shown in figure 9. Plumbing ' - Make-up Box Wiring Pipe and Fitting Specifications Refer to local building and plumbing codes for approved copper pipe and fittings. /4- I ti r... 1 Plumbing Procedures WIRES SHOWN AS SHIPPED, Refer to the installation instructions of the water heating ROUTED FOR LEFT SIDE device to be used with the CBWMV unit. Follow the recom- MAKE-UP BOX INSTALLATION —L mendations outlined in that instruction as well as govern- • ff ing plumbing codes and practices. FOR RIGHT SIDE MAKE-UP 7;.� BOX INSTALLATION— �'� Plumbing Checklist �k • Flush water lines between the CBWMV unit and the REMOVE WIRE TIE, d �1; water heating device before start-up. Normal flushing I PULL EXCESS WIRE INTO 1— procedures should be used to rid the system of con- BLOWER DECK/CONTROL ei� BOX AREA. ,� taminants and foreign debris. W IGI -' • CBWMV units are installed in non-potable systems. Vk aua ISM Electrical „ .�. Wiring and grounding must conform to the current National Electric Code ANSI/NFPA No. 70, or Canadian Electric Code Part I, CSA Standard C22.1, and local building -Ills codes. Refer to following wiring diagrams. See unit name- 0 . . 0 plate for minimum circuit ampacity and maximum over cur- ® rent protection size. - - Select the proper supply circuit conductors in accor- Figure 8 dance with tables 310-16 and 310-17 in the National Electric Code, ANSI/NFPA No. 70 or tables 1 through 4 in the Canadian Electric Code, Part I, CSA Standard Interior Make-Up Box Installation C22.1. MAKE-UP A CAUTION BOX MAKE-UP BOX USE COPPER CONDUCTORS ONLY. \ °" et o ' • AWARNING o Electric shock hazard. Can cause injury o or death. Before attempting to perform iiii any service or maintenance, turn the lir electrical power to unit OFF at disconnect switch(es). Unit may have multiple power 1 V o supplies. LEFT SIDE RIGHT SIDE Refer to figure 12 for schematic wiring diagram and trouble- 4shooting. ••' N. Line Voltage (120V) 4 Line voltage field supply conductors are terminated at the Figure 9 CBWMV unit.The unit is shipped with the line voltage con- RECEIVED Page 7 10/09/18 c WgsgTS BUILDING DEPARTMENT Electrostatic Discharge (ESD) - Precautions And National Electric Code (ANSI/NFPA No. 70) for the Procedures USA and current Canadian Electric Code part 1 (CSA standard C22.1) for Canada. A green ground wire is A CAUTION provided in the field make-up box. 5. Install the room thermostat according to the instruc- Electrostatic discharge can affect electronic compo- tions provided with the thermostat. See table 3 for field nents. Take precautions during air handler installation wiring connections in varying applications. If the air and service to protect the air handler's electronic con- handler is being matched with a heat pump, refer to the trols. Precautions will help to avoid control exposure to FuelMaster21 a installation instruction. electrostatic discharge by putting the air handler, the Removeable Jumpers control and the technician at the same electrostatic po- tential.Neutralize electrostatic charge by touching hand Removeable Jumper DS to Y1—The factory-installed and all tools on an unpainted unit surface, such as the wire jumper that connects terminals DS and Y1 on the TB1 blower deck,before performing any service procedure. terminal strip in the control box must be removed when the air handler is installed in a system supporting dehumidifi- Refer to table 3 for field wiring. cation using a SignatureStat thermostat (e.g., HumidiM - 1. Refer to the CBWMV unit's nameplate for minimum trol®Enhanced Dehumidification Accessory or Harmony zone controls). circuit ampacity and maximum overcurrent protection size. Removeable Jumper R to 0—The factory-installed wire jumper that connects TB7 (24V) terminal R to TB1 termi- 2. Install a separate disconnect switch (protected by ei- nal 0 must be removed when the air handler is installed in ther fuse or circuit breaker)near the air handler so that applications which include a heat pump unit and the Fuel- power can be turned off for servicing. Master21®control board. If the jumper is left intact, termi- 3. Complete the wiring connections to the equipment. nal 0 will remain energized, eliminating the heat mode in Use the provided unit wiring diagram and the field wir- the heat pump. ing diagrams shown in table 3. Use 18-gauge wire or Removeable Jumper Y1 to Y2—The factory-installed larger that is suitable for Class II rating for thermostat wire jumper that connects Y1 and Y2 on the TB1 terminal connections. strip must be removed if two-stage cooling is used. If the 4. Electrically ground the unit according to local codes or, jumper is not removed the outdoor unit will only operate in in the absence of local codes, according to the current second-stage cooling. Table 3 Field Wiring Application Jumper Settings(See figure 12) Thermostat (Application) TB1 Y1 to Y2 TB1 DS to Y1 TB1 R to 0 Wiring Connections 1 Heat/ 1 Cool with Yes No No SignatureStaf CBWMV OUTDOOR SignatureStat'"" Thermostat (Remove) (Remove) TERMINALS UNIT [Single-Stage Heat Pump] 0 C:)\ 0 \..-JUMPERS O Q \`- REMOVED / r,� f O O '/ O 2 Heat/2 Cool with No No No SignatureStaf CBWMV OUTDOOR SignatureStat- Thermostat (Remove) (Remove) (Remove) TERMINALS UNIT [Two-Stage Heat Pump (Refer 0 ®\ to FM21 Instructions)] ® - --© 0 O\,I ALLRE JUMPERS OVED 0 ® 0 O ©r �- -O O/ ® "0" terminal used only with heat pumps. RECEIVED Page 8 10/09/18 505,547M ASPEN BUILDING DEPARTMENT Indoor Blower Speeds Accessory Field Wiring (TB66 & TB67) 1. When the thermostat is set to "FAN ON," the indoor blower will run continuously at approximately 38% of the second-stage cooling speed when there is no cool- Connect wires from accessories (e.g. powered air clean- ing or heating demand. ers, humidifiers) to terminal blocks TB66 and TB67 (see 2. When the CBWMV is in the heating mode, the indoor detail in figure 11). blower will run on the heating speed designated by the position of the HEAT pin. 3. When there is a cooling demand,the indoor blower will run on the cooling speed designated by the position of I CBWMV Control Box the COOL pin. TERMINAL BLOCKS TB2 TB13 (HOT) (NEUTRAL) TRANSFORMER Accessory Field Wiring (K212) 4 -T1 'e�e���1 e. % Connect field wiring to 3PDT relay K212 (Lennox part ,�I1 ' � - . 67K66) as shown in figure 10. DOOR _ I MO irn(14104CB8 CIRCUIT INTERLOCK BREAKER SWITCH �,I `� ,.I�1>,1II Accessory Relay Field Wiring (K212) BDC3 i� ����®® FI `I`'I` •D WIRING VARIABLE STRAIN 1 2 3 CONTROL -' � :1;1111-4t.:.;f1 ��_.-� RELIEF`: ` BUSHING nn nFIELD ORY '.aYY Y�� FIELD TB66 f , • • - 0 WIRING i lep��� �� O 0 TERMINAL TB67 1.,,+p n TERMINAL O D Q 7 8 9 BLOCKS yam+ g00450. (J BLOCK 24V 0 0 o f; ,� _ga O O 0 TERMINAL N� 1:741 1+li o RELAY BLOCK TB1 ACCESSORY RELAY 24V 125MA 1/4"QUICK CONNECT TERMINALS RELAY CONTACTS RATING 8 AMPS @ 120V MAX.24V COIL Figure 11 Figure 10 RECEIVED Page 9 10/09/18 CCWgmES BUILDING DEPARTMENT 120V ACC OR K43 ECON. Typical CBWMV Wiring Diagram (IF USED) G D THERMOSTAT RTION y n ANTI-FREEZE `f THERMOSTAT Eiriaa A2 THERMOSTAT 1 A52 ICONTROL-BDC3 I B3 WHITE O P MOTOR,BLOWER BI9 MOTOR-WATER PUMP N - J46 JICK-IT BREAKER BLACK PUMP J46 JACK-OUTPUT LI (CIRCULATOR) J48 JACK-MOTOR,FRESH AIR BLOWER J49 JACK-MOTOR,VARIABLE SPEED K212 RELAY-FIELD HOOKUP LI3 (CHOKE-POWER n P46 (PLUG-OUTPUT ®® ®® CBWMV P48 PLUG-MOTOR,FRESH AIR BLOWER TB2 12ov id TBL9 12ev CONTROL P49 PLUG-MOTOR,VARIABLE SPEED re2 BBCB DLO orL mama_ BOX S51 SWITCH-DOOR INTERLOCK e - S105 (THERMOSTAT-ANTI-FREEZE 11 5 - TI ITRANSFORMER,CONTROL 551 ncE .rt TBI TERMINAL STRIP DOOR 24v TB2 ERMINAL STRIP-UNIT INTERLOCK LI 0 i i TBee TB7 TERMINAL STRIP Le FIELD CBB O m 0uu,LNG CIRCUIT TBI3 ERMINAL STRIP TB66 TERMINAL STRIP-FIELD HOOKUP TB67 F ,n, FIELD 0 REFER TO FACTORY BLOWER SPEED TAP L 0\ 0 SELECTION CHART FOR BLOWER SPEED uu INFORMATION. TBI REMOVE JUMPER BETWEEN "DS" AND r _>Oc p-o #� m HARMONYEZONINGISUUSEDTAT OR Ir -0e zv®M ____I----O� JUMPER "Yl" TO "Y2" IS FOR I r All SINGLE STAGE COOLING. REMOVE A2 I I I I 0`/2 ®--4-0 JUMPER FOR TWO STAGE COOLING. SlgnafureSla4e I I I I Tinffi 1(212 LT F BE 0 L13 USED ON IHP ONLY THERMOSTAT I Ova I r I I -L -0R O O ® FIELD SUPPLIED ACCESSORY WIRE. -Q JJ I � REMOVE 0 TO TB7-24 JUMPER FOR 11 I 1 1 r---r-- HEAT PUMP APPLICATIONS. bbdbbb I D C R G W Y 1 m FOR HARMONY APPLICATIONS,REMOVE PIN •2(JP49) ON B3 BLOWER MOTOR. I I TAPE WITH ELECTRICAL TAPE TO PREVENT ELECTRICAL PATH. I C U J I _ ® TWO TERMINAL BLOCKS AND A RELAY ARE Y - J INDOOR / ' FACTORY PROVIDED FOR FIELD HOOKUPS u - - -- BLOWER B3 I MOTOR \ BLOWER SPEED TAP SELECTION OUTDOOR _/ BLOWER UNIT COIL COOL HEAT -24B-040 PIN I PIN 2 WARNING- -36B-070 PIN 3 PIN 4 ELECTRIC SHOCK HAZARD, CAN CAUSE INJURY OR DEATH. UNIT -36C-090 PIN 3 PIN 4 MUST BE GROUNDED IN ACCORDANCE WITH NATIONAL AND LOCAL CODES. A2 -60C-I00 PIN 4 PIN 4 NOTE- Si9na}ureS}a}' -60C-I20 PIN 4 PIN 4 IF ANY WIRE IN THIS APPLIANCE IS REPLACED,IT MUST BE REPLACED THERMOSTAT WITH WIRE OF LIKE SIZE,RATING,INSULATION THICKNESS AND TERMINATION ^ `n 9o-7,- - 551 19 9-? ETC) IT/ I DOOR INNTTERLOCK TB7 I L _ - _-_- I LI f� p!� • BLACK TB2-120V-HOT 24 YELLOW ® I I I I 'r- m PINK I I I I L 0 Y TBI I I I I r-- - w I I I I ,® A52 (TB67 r'O TBI _J II I I to to g1 0- ` $ O CBB , 1 , �<-v I I , \j jam,") m ® � _ _ _ J I - <No AS105 ANTI-FREEZE W1 I -II THERMOSTAT al I r (2 ° YELLOW 9FACTORY FURNISHED © b <m<-O�'' 1 FIELD INSTALLED TI - <m‹-p 1 F.: . ‹^<-0 B 19 a TB7 <10� PUMP YELLOW PURPLE /N/ ,� Q (CIRCULATOR) © r" - /\ <—,", I ANDFIELD INSTALLEDEI GREEN/YELLOW GREEN GREEN ja�� GROUND PINK /M I I PURPLE I jN< I e r r e r r e r r i e r err I - LINE — — CLASSY III TAGE VOLTAGELFIELDTALLED WIRING TBI3-120V NEUTRAL Q WHITE N L13 if P49 12 3 4 5 6 7 8 9 10 II 12 13 14 15 16 POWER IL i\AL AL A\AL AL AL AL AL AL AL AL AL AL AL �7p.�� CHOKE 44a 1_ EOUIPMENT 5, • GROUND 4 I • <3, • A ain 2I • I I • B3 Figure 12 RECEIVED Page 10 10/09/18 505,547M ASPEN BUILDING DEPARTMENT Freeze-stat Operation Continuous Low Blower Option Refer to the blower speed chart located on the CBWMV IMPORTANT unit wiring diagram for factory set cooling, heating and low A (continuous) blower speeds. Systems using a cooling ther- mostat subbase may operate continuous blower(factory- Use of the freeze-stat feature is required in all installa- set to operate at 38% of second-stage cooling speed) tions using CBWMV units. through the FAN-ON switch of the thermostat. For continu- The CBWMV unit is equipped with a field-wired freeze- ous low blower with a system without a cooling subbase, a stat. The freeze-stat protects the CBWMV system from fan switching subbase may be used. freezing temperatures when the unit is installed in uncondi- Heating or cooling demand will cause blower to go to heat tioned areas. or cool speed. The factory-provided freeze-stat must energize the circu- Blower Speed Adjustments lator when water temperatures fall below 45°F. Freeze-stat wiring is shown in figure 13. Diagnostic LEDs RUN LED — Indicates a demand for blower operation in N Freeze-stat Field Wiring LI either the heating mode or continuous fan-only mode. ! RUN LED will not illuminate during a cooling demand. CFM LED—Indicates the CFM at which the unit is operat- ing. The light flashes once for approximately every 100 ____ __ _ _ _ CFM. For example, if the unit is operating at 1000 CFM, 0-0-�- DOOR CFM LED will flash 10 times. If the CFM is 1150, CFM LED NEUTRAL Y I INTERLOCK B19 9105 0-0 PUMP ANTI-FREEZE TBB, I will flash 11 full times plus one fast or half flash. FIELD FURNISHED THERMOSTAT IJ'L'iFIELD INSTALLEDAND INSTALLED FACTORY FURNISHED Ic'i At times the light may appear to flicker or glow. This takes place when the control is communicating with the motor TBz-izov HOT between cycles. This is normal operation. The appropriate speed according to application and CFM Figure 13 need is selected by moving jumper pins. BDC3 Variable Blower Control Board BDC3 Variable Speed Control Board CBWMV units are equipped with a variable speed motor O O 0 that is capable of maintaining a specified CFM throughout ° . ° JP1 o /o 0 0 /o the external static range.A particular CFM can be obtained JP1 o ° by positioning jumpers (COOL, HEAT, and ADJUST) on 15 PIN PLUG TO the BDC3 control board. The COOL and HEAT jumpers (BOARD OMOTOR) LENNOX are labeled 1, 2, 3, and 4. Each of the numbers corre- ACCESSORY II II sponds with an air volume (CFM) setting. The ADJUST RELAY CON- h J. jumper is labeled TEST, -, +, and NORM. The + and - pin TACTS Acc [1settings are used to add or subtract a percentage of the (DRIVTOOESOAK4v/IA ACCESSORY CFM selected. The TEST jumper is used to operate the RELAY) , motor in the test mode. The DELAY jumper controls ramp- OPERATIONAL ing profiles. SELECTOR\0 o NORM o 0 4 0 0 4 0 0 4 Figure 14 shows the BDC3 control board. Use tables 5 PINST 0 0 • 0 0 2 0 0 2 0 0 2 - g (AFFECTS 0 o - 0 02 0 0 2 0 02 through NO TAG to determine the correct air volume for BOTH ®TEST 1a�0 1 ®1 ®1 g HEATING AND ADJUST HEAT COOL DELAY M oe heat and cool speed taps. COOLING MOOL s> O O Diagnostic LEDs located on the BDC3 control board are provided to aid in identifying the units mode of operation. HEATING SPEED COOLING SPEED FAN DELAY DIAGNOSTIC Certain scenarios will arise depending on the jumper posi- SELECTOR PINS SELECTOR PINS SELECTOR PINS LEDS tions. Read through the jumper settings sections before adjusting blower speed. Refer to figure 14 for identification. Figure 14 RECEIVED Page 11 10/09/18 CAw1 mES BUILDING DEPARTMENT Jumper Settings For applications with the Harmony® Zoning System, the blower CFM volume is determined by the Harmony control center. The minimum blower speed is predetermined at A IMPORTANT 400 CFM for -CBWMV-24B-040 and 36B-070 series units and 600 CFM for CBWMV-36C-090, 60C-100, and Before changing jumper setting, make sure the motor 60C-120 series units. This speed is not adjustable. has completely stopped. Any jumper setting change will With the thermostat set for"Continuous Fan"and without a not take place while the motor is running. call for heating or cooling, the CBWMV will provide 38%of the COOL CFM selected. HEAT Pins — The HEAT jumper is used to determine Table 4 shows the factory blower speed tap settings for CFM heating. These jumper selections are activated only CBWMV series units. These settings are for nominal ton- when W1 is energized. (There is a fixed 45 seconds ON nage match-ups with the CBWMV. When matched with and 30 seconds OFF delay on a W call.) other sizes, it is recommended that the CFM be adjusted DELAY Pins—The DELAY jumper is used to set the spe- approximately to 400 CFM per ton. cific motor fan operation during cooling mode. Depending on the application, one of four options may be chosen by Table 4 moving the jumper to the appropriate set of pins. Factory Blower Speed Tap Settings #1 Pins Jumpered — CBWMV Speed Tap Selection Blower A Motor runs at 100% until demand is satisfied. Coil Cool Pin Heat Pin Adjust Delay A B -24B-040 1 2 NORM 4 -36B-070 3 4 NORM 4 OFF OFF -36C-090 3 4 NORM 4 B Once demand is met, motor ramps down to stop. -60C-100 4 4 NORM 4 -60C-120 4 4 NORM 4 #2 Pins Jumpered — To change jumper positions, gently pull the jumper off the A Motor runs at 100% until demand is satisfied. pins and place it on the desired set of pins. The following A B C section outlines the different jumper selections available and conditions associated with each one. Refer to figure OFF OFF 14. B Once demand is met, motor runs at 100% for 45 After the CFM for each application has been determined, seconds. Then, the jumper settings must be adjusted to reflect those given C ramps down to stop. in tables 5 through NO TAG. From the tables, determine NOTE-Blower OFF DELAY also applies during heat which row of CFM volumes most closely matches the de- pump operation sired CFM. Once a specific row has been chosen (+, NOR- MAL, or-), CFM volumes from other rows cannot be used. #3 Pins Jumpered — Below are descriptions of the jumper selections. A Motor runs at 82% for approximately 7-1/2 min- utes. ADJUST Pins—The ADJUST pins allow the motor to run ina If demand has not been satisfied after 7-1/2 m at normal speed, approximately 10% higher, or approxi- minutes, °/o until demand is satisfied. mately 10% lower than normal speed. Tables 5 through B motor runs at 100 NO TAG gives three rows (+, NORMAL, and -)with their A B, C respective CFM volumes. Notice that the normal adjust- ment setting for heat speed position#3 is 1070 CFM.The+ OFF / OFF adjustment setting for that position is 1180 CFM and for the C Once demand is met, motor ramps down to stop. -adjustment setting is 940 CFM. After the adjustment set- ting has been determined, chose the remainder speed #4 Pins Jumpered — jumper settings from those offered in the table in that row. A Motor runs at 50% for 30 seconds. The TEST pin is available to bypass the BDC3 control and B Motor then runs at 82% for approximately 7-1/2 run the motor at approximately 70%to test that the motor is minutes. If demand has not been satisfied after operational. This is beneficial primarily in troubleshooting. 7-1/2 minutes. G must be energized for motor to run. C Motor runs at 100% until demand is satisfied. D Once demand is met, motor runs at 50% for 30 COOL Pins—The COOL jumper is used to determine the seconds. Then, CFM during either 1) cooling or 2) heat pump operation without a W1 call for electric heat.These jumper selections A B C, - D E are activated for cooling when Y1 and/or Y2 and DS termi- rj nals in the CBWMV unit are energized and for heating OFF when Y1 and/or Y2 is energized. E ramps down to stop. RE IVED Page 12 10/09/18 505,547M ASPEN BUILDING DEPARTMENT Table 5 CBWMV-24B-040 Blower Performance 0 through 0.80 in.w.g.External Static Pressure Range "ADJUST" Blower Control Jumper Speed Positions Jumper "HEAT"Speed-cfm First Stage"COOL"Speed-cfm Second Stage"COOL"Speed-cfm Setting 1 1 2 3 4 1 1 2 3 4 1 1 2 3 4 + 820 990 1180 1340 610 770 930 1010 880 1120 1340 1440 1 NORM 750 900 1070 1230 560 700 830 910 800 1000 1200 1300 — 670 810 940 1080 510 630 750 810 720 900 1080 1170 CBWMV-36B-070 Blower Performance 0 through 0.80 in.w.g.External Static Pressure Range "ADJUST" Blower Control Jumper Speed Positions Jumper "HEAT"Speed-cfm First Stage"COOL"Speed-cfm Second Stage"COOL"Speed-cfm Setting 1 2 3 1 4 1 2 1 3 4 1 2 1 3 4 + 790 980 1140 1310 590 745 895 975 850 1090 1300 1430 1 NORM 730 870 1040 1190 545 680 805 890 775 990 1190 1280 — 640 770 920 1070 490 600 725 780 700 870 1065 1150 CBWMV-36C-090 Blower Performance 0 through 0.80 in.w.g.External Static Pressure Range "ADJUST" Blower Control Jumper Speed Positions Jumper "HEAT"Speed-cfm First Stage"COOL"Speed-cfm Second Stage"COOL"Speed-cfm Setting 1 2 3 1 4 1 2 1 3 4 1 2 1 3 4 + 820 1000 1180 1340 620 770 930 1010 890 1130 1340 1450 1 NORM 760 900 1070 1220 570 700 830 910 800 1020 1220 1310 675 810 950 1100 520 630 760 810 720 900 1100 1180 CBWMV-60C-100 Blower Performance 0 through 0.80 in.w.g.External Static Pressure Range "ADJUST" Blower Control Jumper Speed Positions Jumper "HEAT"Speed-cfm First Stage"COOL"Speed-cfm Second Stage"COOL"Speed-cfm Setting 1 2 3 1 4 1 2 3 1 4 1 2 3 1 4 + 1500 1700 1880 2100 1110 1250 1380 1530 1540 1760 1970 2200 1 NORM 1370 1540 1720 1920 1000 1130 1250 1380 1400 1600 1800 1980 1250 1380 1540 1720 930 1040 1130 1260 1270 1420 1600 1780 CBWMV-60C-120 Blower Performance 0 through 0.80 in.w.g.External Static Pressure Range "ADJUST" Blower Control Jumper Speed Positions Jumper "HEAT"Speed-cfm First Stage"COOL"Speed-cfm Second Stage"COOL"Speed-cfm Setting 1 2 3 14 1 2 3 14 1 2 3 14 + 1510 1720 1900 2120 1100 1250 1400 1560 1570 1800 2000 2200 1 NORM 1380 1560 1740 1920 990 1130 1260 1400 1410 1620 1820 2020 — 1240 1380 1540 1720 930 1020 1130 1260 1260 1440 1620 1810 1 Factory default jumper setting. NOTES- The effect of static pressure and filter resistance is included in air volumes shown. First stage COOL is approximately 70%of the same second stage COOL speed position. Continuous Fan Only speed is approximately 38%of the same second stage COOL speed position. Harmony IIITM Zoning System applications-Minimum blower speed: 250 cfm for-24B-40,-36B-070,-36C-090. 450 cfm for-60C-100. 380 cfm for 60C-120. Maximum air volume is the same as second-stage cool position. Applications with single sided inlets will reduce the air volume by approximately 4%on B-size units and 5%on C-size units. RECEIVED Page 13 10/09/18 BUILDING DEPARTMENT Initial Air Purging Refer to the speed selection chart on unit wiring diagram. After all plumbing connections have been made, leak NOTE-To check for proper CFM, take the reading exter- nal tested and flushed, the water heating device is ready to be ea the unit. The coil must be dry when you take the r filled with water and purged of air. Air bleeder valves are reading. provided as a convenience for installations that are not Annual Service equipped with purge manifolds. 1. Make sure electrical power and gas supply to system A WARN I N G are OFF. Electric shock hazard. Can cause injury 2. Remove CBWMV coil section access panel. or death. Before attempting to perform 3. Remove cap from highest air bleed valve and depress any service lir er maintenance, turn the valve stem until water is released.This may be done with electrical power to unit OFF at disconnect a refrigerant style hose. See figure 15. sppy es). Unit may have multiple power suupplies. 4. Replace cap on valve and access panel. At the beginning of each heating season, system should be 5. Apply electrical power and gas supply to the system. checked as follows by a qualified service technician: 6. Follow the System Start-Up section to operate the sys- Electrical tern. Complete purging of air after unit has gone 1. Check all wiring for loose connections. through initial start-up. 2. Check for correct voltage at CBWMV unit(unit operat- ing). 3. Check to see that blower is operating. Air Bleed Valve Location Blower 1. Check and clean blower wheel. %, N 2. Motors are pre-lubricated for extended life; no further lubrication is required. 'S Freeze-stat - Verify that the freeze-stat functions. - Service Filters 4 Filters must be cleaned or replaced when dirty to assure `/� proper unit operation. - `� I Winterizing CBWMV Water Coil `�A If unit is installed in an unconditioned space, the piping be- t!, tween the CBWMV unit and the water heating device should be insulated. If power is removed from the unit,wa- ter must be drained from the system to prevent freezing. SHOWN '/ Repair Parts List WITH CAP ON The following repair parts are available. When ordering parts, include the complete unit model number listed on the �� unit rating plate of each piece of equipment. ��% ♦ Cabinet Parts • Blower Access Panel �i • Coil Access Panel Figure 15 Hot Water Coil Parts • Coil Replacement Kit Blower Part System Adjustments • Blower Wheel • Blower Motor Timed-ON and Timed-OFF Delays • Blower Housing The 45-second timed-ON delay and the 30-second timed- Electrical Parts OFF delay for heating (time that the blower operates after the heat demand has been satisfied) is not adjustable. • BDC3 Board • Blower Speeds Transformer Select the blower speed by moving the pins on the variable • Circuit Breaker, 24VAC RECEIVE speed control board. See figure 14. • 3PDT Relay Page 14 10/09/18 505,547M ASPEN BUILDING DEPARTMENT Troubleshooting: Continuous Fan Sequence of Operation CONDITIONS: Power On Normal Operation LED: Steady Flash Thermostat(S1)Calls for Continuous Fan,G-Only NO i Check for 24 Volts Between'G'and C at Al 5 Terminal Strip YES 1 Blower Operates at the Continuous Fan Speed NO Selected by COOL Jumper and ADJUST Jumper ► Check for 24 Volts Between Pins 3 and 15 on J49 Positions on the BDC3 Control(A52) - YES 4, RUN Light on BDC3 Control(A52)illuminates to Indi- cate a Continuous Fan Call YES 4, CFM Light on A52 Indicates Blower CFM Selection with 100CFM/Blink YES 4 Thermostat(S1)Continuous Fan Demand Satisfied YES 11, Blower Off [roubleshooting: Heating Sequence of Operation CONDITIONS: Power On Normal Operation LED: Steady Flash Thermostat(S1)Calls for Heat NO Check for 24 Volts Between YES W and C at A52 Terminal Strip V Fixed blower-ON delay(45-second)complete Blower Operates at the Heating Speed Selected by HEAT Jumper and ADJUST Jumper Positions on NO > Check for 24 Volts Between Pins 3 and 2 on J49 the BDC3 Control(A52) YES CFM Light on A52 Indicates Blower Speed Selection with 100CFM/Blink YES Thermostat(S1)Demand Satisfied YES 1 30 Second Blower Off Delay Fixed Complete YES 1 Demand for Heat Satisfied RECEIVED Page 15 10/09/18 cAwgmEs BUILDING DEPARTMENT Troubleshooting: Cooling Sequence of Operation CONDITIONS: Power On Normal Operation LED: Steady Flash Thermostat(S1)Provides 24 Volt Cooling Call to In- NO door Blower(B3) t Check for 24 Volts Between Y and C at Al 5 Terminal Strip YES Blower(B3)Operates at the 2nd Stage NO Check for 24 Volts 2 Stage Condensing Unit? NO ► Cooling Speed Determined by COOL, ► Between Pins 14 and DELAY and ADJUST Jumper Positions on 3 on J49 YES the BDC3 Control(A52) V YES Blower(B3)Operates at the 1st Stage Cooling Speed CFM Light on A52 Indicates Blower CFM Determined by COOL,DELAY and ADJUST Jumper NO Selection with 100CFM/Blink Positions on the BDC3 Control(A52) CFM Light on A52 Indicates Blower CFM Selection with YES 100CFM/Blink Thermostat(S1)Demand Satisfied YES YES Check for 24 Volts Between Y Blower Shuts Off According to the DELAY and C on A15 Terminal Strip Jumper Position on the BDC3 Control (A52) Check for 24 Volts Between Pins 6 and 3 on J49 YES Demand for Cooling Satisfied V A 0-First Stage Demand for Cooling Satisfied? NO No Thermostat(S1)Calls for Check for 24 Volts Between Y2 on 2nd Stage Cooling TB1 and C on A15 Terminal Strip YES YES Blower Shuts Off According to the DELAY Jumper Blower Operates at the 2nd NO Check for 24 Volts Between Pins 14 Position on the BDC3 Control(A52) Stage Cooling Speed Deter- and 3 on J49 mined by COOL,DELAY and YES + ADJUST Jumper Positions Demand for Cooling Satisfied on the BDC3 Control(A52) YES CFM Light on A52 Indi- cates Blower CFM Selec- tion with 100CFM/Blink YES 2nd Stage Thermostat (S1)Demand Satisfied YES Blower Returns to 1st Stage Cooling Speed RECEIVED Page 16 10/09/18 505,547M ASPEN BUILDING DEPARTMENT WATER HEATING / BOILERS CBWMV LENNOX Residential Hot Water Heat Air Handler PRODUCT SPECIFICATIONS Bulletin No.210434 June 2014 Supersedes January 2013 LEN roX l!IPN Heating Capacity - 23,700 to 220,000 Btuh Nominal Add-On Cooling - 2 to 5 Tons MODEL NUMBER IDENTIFICATION CBWMV - 24B - 070 - 3 Unit Type Minor Revision Number CBW=Air Handler with Hot Water Coil Configuration Nominal Water Coil Heat M=Multi-Position 040=40,000 Btuh 070=70,000 Btuh 090=90,000 Btuh Blower 100=100,000 Btuh V=Variable Speed Blower 120=120,000 Btuh Nominal Cooling Capacity-Tons RECEIVED 024=2 tons Cabinet Width 036=3 tons B= 17-1/2 in. 060=5tons C=21 in. 10/09/18 ASPEN BUILDING DEPARTMENT FEATURES CONTENTS Blower Data 9 lekplW Dimensions 6 Dimensions - Furnace/Coil Combined Combinations 8 Electrical Data 5 Features 2 Field Wiring 5 / 0Heating Performance 10 7 id, Installation Clearances 5 Model Number Identification 1 Optional Accessories 5 00, Q� Optional Accessory Dimensions 7 Specifications 5 �j WARRANTY All covered components - Limited warranty for ten _� � ,,j years limited warranty in residential applications. , ! ; \ 0:: Refer to Lennox Equipment Limited Warranty certificate '0 �� ` included with equipment for details. �, I SEQUENCE OF OPERATION CBWMV includes supply air blower, hot water coil, and blower control.A circulating pump can be ordered extra for field installation. After a 45-second (fixed) timed-on delay the blower energizes at heating speed. After a 30-second (fixed) timed-off delay the supply air blower shuts off. HEATING SYSTEM APPROVALS 0 Hot Water Coil Units certified by CSA International. Corrugated/lanced aluminum fins. Blower data from unit tests conducted in Lennox Seamless corrosion resistant copper tubes. Laboratory air test chamber. Fin collars grip tubing for maximum contact area. APPLICATION Flared shoulder tubing connections and silver soldering CBWMV can be used with properly sized gas-fired or provides tight, leakproof joints. oil-fired water heating devices. Factory tested under high pressure. Cannot be used with potable water. Entire coil accessible for cleaning. Supply air blower moves the return air past the coil to extract the heat and then distribute the heated air Freezestat throughout the conditioned space. Protects system from freezing temperatures when unit is installed in unconditioned areas. CBWMV is a multi-position (upflow, downflow, or horizontal) blower/hot water coil unit. Thermostat automatically energizes circulating pump when water line temperature falls below 45°F. Lennox add-on indoor coil with remote air conditioning unit, air cleaners, automatic humidifier, and all Lennox Optional Accessories Indoor Air Quality products can easily be added for a Circulating Pump complete all season system. Bronze construction, Non-metallic impeller with Carbon Zoning Applications bearings. Units may be used with certain zoning systems. Self lubricating. Zone control panel must be able to interface and Impedance protected. RECEIVED communicate with the variable speed blower motor in Motor and impeller removable as single unit or the unit. Lennox Harmony IIITM Zoning System has this servicing. 10/0 9/18 capability. CBWMV /Page 2 ASPEN BUILDING DEPARTMENT FEATURES CABINET Air Filter and Rack Kit for Upflow Side Return Air 0 Heavy gauge cold rolled steel constructed. Applications - Not for use with RAB Return Air Base Pre-painted cabinet finish. Washable or vacuum cleanable polyurethane frame type filter and external side return air rack available for Foil faced fiberglass insulation on hot water coil access field installation. door panel, side panels and on back panel reduces cabinet temperatures. Available in single and ten pack kits. Black mat faced fiberglass in blower compartment Rack has filter door for easy filter servicing. assures quiet operation. Flanges on rack allow easy duct connection. Complete service access by removing hot water coil Field installs on either side of unit cabinet. See section and blower compartment access panels. dimension drawing. Blower assembly completely removable for easy EZ Filter Base for Upflow Bottom Return Air servicing. Applications Blower deck rails angle down for easy blower removal. Hinged door with thumbscrew for easy filter access. Electrical inlets in both sides of the cabinet. Uses standard size filters (field provided). Safety interlock switch automatically shuts off power to BLOWER unit when blower compartment access door is removed. Variable Speed Blower Motor Return air entry on either side or bottom of cabinet. Variable speed motor(VSM) maintains specified air CBWMV is applicable to upflow, horizontal, or downflow volume from 0 though 0.80 in. w.g. static range. installations. Gradual acceleration and deceleration of variable speed Field Make-up Box blower motor when starting and stopping over a specific Furnished for line voltage wiring. time frame results in extremely quiet operation. Box may be installed on either side of CBWMV cabinet. Variable speed operation is achieved by the use of an ECM (Electronically Commutated Motor) motor. Cabinet- continued Motor is controlled by Electronic Blower Control. Optional Accessories Motor is resiliently mounted. Horizontal Support Frame Kit When units are used with Harmony III TM Zoning System, Provides support of unit in horizontal applications. blower motor operates from predetermined minimum to Consists of(2) 1 x 1-1/2 x 32-5/8 in. and (2) 1 x 3 x maximum air volumes to satisfy zone requirements. 53-7/8 in. painted heavy gauge cold rolled steel support channels with assembly and suspending holes. 0 Variable Speed Blower Bolts and nuts furnished for field assembly. Each blower assembly statically and dynamically balanced. Suspending rods must be field provided. Change in blower speed is easily accomplished by RAB Return Air Base simple jumper pin position change on Electronic Blower "C" and "D"width bases required with 60C models with Control. air volumes over 1800 cfm in up-flow applications when Blower assembly completely removable for easy only one side return is used. servicing. "B"width base is not required but may also be used to See blower performance tables. provide clearance in certain applications (if required). Cabinet is pre-painted steel to match the furnace. See Dimension Drawing. Air Filter and Rack Kit for Horizontal Return Air (End)Applications Washable or vacuum cleanable polyurethane frame type filter and external end return air rack available for field installation. Rack has filter door for easy filter servicing. Flanges on rack allow easy duct connection. See dimension drawing. RECEIVED 10/09/18 BUIL5 i4 ?1/1tNT FEATU RES CONTROLS Optional Accessories 0 Electronic Blower Control ComfortSense°7000 Touchscreen Thermostat Interfaces variable speed motor with thermostat. Electronic 7-day, universal, multi-stage, programmable, Controls evaporator humidity by controlling blower and touchscreen thermostat. compressor speed on two-stage outdoor units. 4 Heat/2 Cool. Two COOL speeds and one HEAT speed (with four Auto-changeover. o nnoF different air volume selections for each)are made by Controls humidity during � '—"—' sc° simple jumper pins on board. cooling mode. ADJUST jumper pin allows approximately 10% higher, Offers enhanced capabilities normal, or 10% lower motor speed selection within including humidification / HEAT and COOL speeds selected for fine tuning the air dehumidification /dewpoint volume. measurement and control, Humiditrol®control, and DELAY jumper pin allows selection blower motor de- equipment maintenance reminders. humidification profiles during cooling mode. Easy-to-use, menu driven thermostat with a back-lit, Option 1 - Motor runs at 100% of capacity until demand LCD touchscreen. met. Once demand is met, motor ramps down to stop. Remote outdoor temperature sensor(optional)allows Option 2 - Motor runs at 100% of capacity until demand the thermostat to display outdoor temperature. Required is satisfied. Motor runs at 100% of capacity for 60 in dual-fuel and Humiditrol®applications. seconds then ramps down to stop. See the CornfortSense° 7000 Product Specifications Option 3- Motor runs at 82% of capacity for bulletin in the Controls section for more information. approximately 7-1/2 minutes. If demand is not satisfied, motor runs at 100% capacity until demand is satisfied. Thermostat Once demand is met, motor ramps down to stop. See Thermostat bulletins in Controls section and Option 4 - Motor runs at 50% capacity for 30 seconds, Lennox Price Book for a complete list of thermostats. then 82% capacity for approximately 7-1/2 minutes. If demand is not satisfied, motor runs at 100% capacity until demand is met. Once demand is met, motor runs at 50% capacity for 30 seconds, then ramps down to stop. Control has two diagnostic indicator lights, "CFM" and "RUN", to assist in servicing. Accessory relay terminals provide connections for power humidifiers or electronic air cleaners. Control is factory installed in the unit control box. 24 Volt Transformer Furnished in CBWMV control box. RECEIVED 10/09/18 CBWMV /Page 4 ASPEN BUILDING DEPARTMENT SPECIFICATIONS Model No. CBWMV CBWMV CBWMV CBWMV CBWMV -24B-040 -36B-070 -36C-090 -60C-100 -60C-120 Heating Nominal heating capacity-Btuh 40,000 70,000 90,000 100,000 120,000 Performance ' Temperature rise range-°F 32- 101 45- 125 51 - 125 41 - 113 45- 125 Indoor Wheel nominal diameter x width-in. 10 x 8 10 x 8 10 x 8 11-1/2 x 10 11-1/2 x 10 Blower Blower motor output-hp 1/2 1/2 1/2 1 1 Tons of add-on cooling 2-3 2-3 2-3 3.5-5 3.5-5 Heating Heating capacity range-Btuh 23,700- 30,300- 31,400- 49,600- 55,000- Coil 84,700 123,800 138,400 181,700 220,000 Net face area-sq.ft. 3.83 3.83 4.33 4.33 4.33 Tube diameter&no. of rows-in. 3/8- 1 3/8-2 3/8-2 3/8-2 3/8-3 Fins per inch 16 16 16 16 16 Required pump flow rate for coil capacity rating-GPM 6 6 9.5 9.5 9.5 Water Line Connections Inlet 3/4 3/4 1 1 1 (sweat)- in. I.D. Outlet 3/4 3/4 1 1 1 Shipping Data lbs.- 1 package 127 144 157 157 165 ELECTRICAL DATA Electrical characteristics 120 volts-60 hertz- 1 phase 2 Maximum Overcurrent Protection 15 15 15 20 20 Minimum Circuit Ampacity 10.2 10.2 10.4 16.8 16.8 OPTIONAL ACCESSORIES (ORDER SEPARATELY) 3 Air Filter& Horizontal (end)-in. 87L96 87L97 Rack Kit 18 x 25 x 1 20 x 25 x 1 in. Side Return-in. Single 44J22 or Ten Pack(66K63)-(1) 16 x 25 x 1 Circulating Catalog Number 99K69 99K69 53J76 53J76 53J76 Pump Motor output-hp 1/40 1/40 1/25 1/25 1/25 Capacity-U.S. GPM 0-10 0-10 0-14 0-14 0-14 Pressure drop thru coil @ rated flow-psi 3 3 3 3 3 ComfortSense®7000 Thermostat Y2081 Y2081 Y2081 Y2081 Y2081 Remote Outdoor Sensor(for dual fuel and Humiidtrol®) X2658 X2658 X2658 X2658 X2658 EZ Filter Base Catalog Number 73P56 73P57 Dimensions-H x W x D-in. 4 x 17-5/8 x 28-5/8 4 x 21-5/8 x 28-5/8 Size of field provided filter-in. 16 x 25 x 1 20 x 25 x 1 Horizontal Support Frame Kit 56J18 56J18 56J18 56J18 56J18 RAB Return Air Base 98M60 98M58 'Minimum temperature rise is based off 140°F entering water temperature and the maximum heating air volume.Maximum temperature rise is based off 200°F entering water temperature and the minimum heating air volume using the Harmony III TM Zoning System. 2 HACR type breaker or fuse. 'Cleanable polyurethane frame type filter. FIELD WIRING INSTALLATION CLEARANCES r DISCONNECT, CBWMV Upflow/ CBWMV Horizontal I SWITCH I Downflow L (by other) J Q Sides 0 inches (0 mm) 0 inches(0 mm) CBWMV Rear 0 inches (0 mm) 0 inches(0 mm) UNIT Q Top 0 inches (0 mm) ' 0 inches(0 mm) r— --i Front 2 0 inches(0 mm) 2 0 inches(0 mm) OPTIONAL I THERMOSTAT I Floor Combustible 0 inches(0 mm) A - Two wire power with ground NOTE-Termination location must conform to the met ti :.; r'`o' 1 B - Three wire control voltage(Heating Only) National Standard(ANSI-Z223.1)National F. *do ", &f� ill (Cooling) Sta dard of Canada CAN/CGA-149.1,and C --14b. iistaflati Four wire control voltage Code for Gas Burning Appliances". Five wire control voltage (2-Stage Cooling) 'Line contact installation permissible between jacket top or ioQ3/r Y9ilj491 8 - Field wiring not furnished - joists All wiring must conform to NEC or CEC and local electrical codes. 2 Front clearance for alcove installations is 30 in. BUIL5 1 41111 NT DIMENSIONS - INCHES (MM) 1 NOTE -Single side inlet applications result in approximately 4% reduction of air volume on B-size units and approximately 5% reduction of air volume on C-size units. WATER INLET I SUPPLY AIR 2 Optional External Side Return Air Filter Kit is not for use with OPENING the optional RAB Return Air Base. F WATER OUTLET D 4 2 OPTIONAL 23-3/4(603) EXTERNAL SIDE RETURN 25(635) 10 AIR FILTER KIT TOP VIEW (Either Side) A 28-1/2 (724) 9/16 B +9/16(14) 1(4994) (14) ALTERNATE WATER INLET 1 o o (Left Side Only) 1-1/4itoil (32) t 1-3/4 10-1/2 (44) (267) ALTERNATE 2 OPTIONAL WATER OUTLET EXTERNAL (Right Side Only) V SIDE RETURN AIR FILTER KIT 2 "N— ELECTRICAL INLET (Either Side) (51) (Either Side) 40 °o° (1016) —f 0 I I 14-3/4 102 584) P) (375) ( )1 ( At 16 OPTIONAL 14 (406) I RETURN CUTOUT (356) I (Either Side) AIR FLOW L _JI v 1-15/116(49) 4 5/8 (16) 23-1/2597 pp.] -.IL. C 3/4(19) ( ) 3/4(19) Bottom Return 4-1/4 Bottom Return Air Opening (108) Air Opening FRONT VIEW SIDE VIEW A B C D E F G Model No. in. mm in. mm in. mm in. mm in. mm in. mm in. mm CBWMV 24B 040 17-1/2 446 16-3/8 416 16 406 1-1/2 38 1-3/4 44 8 203 2 51 CBWMV-36B-070 CBWMV-36C-090 CBWMV-60C-100 21 533 19-7/8 454 19-1/2 495 2 51 2-1/2 64 9-1/2 241 1-1/2 38 CBWMV-60C-130 ECEIVED 10/09/18 CBWMV /Page 6 ASPEN BUILDING DEPARTMENT OPTIONAL ACCESSORY DIMENSIONS - INCHES (MM) HORIZONTAL FILTER KIT 24-3/4 1-1/4(32) rill5/8(629) 1 i liml(16) 5/8 NI (16) B RETURN I A AIR OPENING AIR FLOW 23-1/2_11,. 5/8 (597) (16) T ' L I AIR FILTER 5/8 4 (Furnished) (16) SIDE VIEW FRONT VIEW A B Catalog Number - inch mm inch mm 87L96 18 457 16-3/4 425 87L97 21 533 18-3/4 476 RAB RETURN AIR BASE (Upflow Applications Only) — 4 1.411— 1 23(584) f op J Il (102)1 Overall 1 Minimund 5 (Maximum) 11 (279) (36) 2 Maximu 1 22-7-16 1 Unit side return air 141 3.56 (570) AIR FLOW AIR HANDLER L Opening ' )J Overall lirFRONT 11 (Maximum) 5-5/8 SIDE RETURN 7-1/4(184) (143) AIR OPENINGS _t_ 4 (Either Side) _ ► 14 23(584) 3/4 I� OPTIONAL RAB 17-1/2(446) RAB-B(98M60) RETURN AIR BASE (19) 21 (533) RAB-C (98M58) �22) -4 27-5/8(702) 0 SIDE VIEW FRONT VIEW NOTE-Optional Side Return Air Filter Kits are not for use with RAB Return Air Base. 1 Both the unit return air opening and the base return air opening must be covered by a single plenum or IAQ cabinet. Minimum unit side return air opening dimensions for units requiring 1800 cfm or more of air(W x H):23 x 11 in.(584 x 279 mm). The opening can be cut as needed to accommodate plenum or IAQ cabinet while maintaining dimensions shown. Side return air openings must be cut in the field.There are cutting guides stenciled on the cabinet for the side return air opening.The size of the opening must not extend beyond the markings on the furnace cabinet. 2 To minimize pressure drop,the largest opening height possible(up to 14 inches)is preferred. NOTE-Optional Side Return Air Filter Kits are not for use with RAB Return Air Base. RECEIVED 10/09/18 aspmt BUIL6JliNT DIMENSIONS - INCHES (MM) - FURNACE/COIL COMBINED COMBINATIONS UPFLOW POSITION UPFLOW POSITION Cased Uncased / Model No (CX34-cased only) A B A B // \� I A in. mm in. mm in. mm in. mm //��11^\ CX34 18/24C 6FC33-24C 16 1/2 419 56 1/2 1435 13 7/8 352 53 7/8 1368 0X34-25B-6F C33-25B 19-1/2 495 59-1/2 1511 15-7/8 403 55-7/8 1419 / B CX34-30B-6F C33-30B CX34-30C-6F C33-30C 20-1/2 521 60-1/2 1537 17-3/4 451 59-3/4 1467 40/j. 0X34 31 B 6F C33-31B 23 1/2 597 63 1/2 1613 20-1/4 514 60-1/4 1530 , (1016) 0X34 36B 6F C33-36B 24-1/2 622 64-1/2 1638 21-7/8 556 61-7/8 1572 0X34-360-6F 033-360 24-1/2 622 64-1/2 1638 21-1/4 540 61-1/4 1556 0X34-38B-6F C33-38B 24-1/2 622 64-1/2 1638 22 559 62 1575 0X34-42B-6F C33-42B 24-1/2 622 64-1/2 1638 21-7/8 556 61-7/8 1572 0X34-43B-6F 033-43B 28-1/2 724 68-1/2 1740 26-1/4 667 66-1/4 1683 DOWNFLOW POSITION 0X34-430-6F 033-430 28-1/2 724 68-1/2 1740 25-3/4 654 65-3/4 1670 CBWMV Width 033-440 24-1/2 622 64-1/2 1638 21-1/2 546 61-1/2 1562 / CX34-44/48B-6FC33-48B 24-1/2 622 64-1/2 1638 22-1/8 562 62-1/8 1578 /� • CX34 44/48C 6FC33 1 CX34-49C-6F C33-49C 48C 29-1/224 1/2 749622 70-1/264 1/2 1791 1638 21 28-1/2 1/2 724546 61 68-1/2/2 17415620 CX34-50/60C-6FC33-50/60C27-1/2 699 67-1/2 1715 24-3/4 629 64-3/4 1645 40 0X34-620-6F 033-620 32-1/2 826 72-1/2 1842 30-5/8 778 70-5/8 1793 (1016) Overall \ Height DOWNFLOW POSITION :k%3,] Model Coil Width Furnace Overall Width Coil Height Height 1 Number 1 in. mm in. mm in. mm in. mm ,- Coil Height 0R33 24B F 17-1/2 446 17-1/2 446 13-1/4 337 53-1/4 1353 -' i 0R33-30/36B-F 17-1/2 446 17-1/2 446 16-1/8 410 56-1/8 1426 i i� 0R33-30/360-F 21 533 21 533 16-1/8 410 56-1/8 1426 1 NOTE—Downflow applica- 4 �� 0R33-48B-F 21 533 17-1/2 446 20 508 60 1524 tions with add—on cooling coil Coil require field-fabricated transi- CR33-48C-F 21 533 21 533 20 508 60 1524 tions to provide adequate Width clearance for servicing/remov- CR33-50/60C-F 24-1/2 622 21 533 23-5/8 600 53-5/8 1362 ing the cooling coil without cutting the water lines. See Installation Instructions. HORIZONTAL HORIZONTAL POSITION Model A B Number in. mm in. mm B 40 CH33-25B-2F (1016) CH33-31 B-2F CH33-36B-2F CH33-36C-2F 26-1/2 673 66-1/2 1689 A CH33-42B-2F CH33-43C-2F // CH33-48C-2F /j/ �� 0 CH33-43B-2F r�-i i CH33 44/48B 2F 31 1/2 800 71 1/2 181�� ���� CH33-49C-2F CH33 50/60C 2F � II "� I� � Ill D 10/09/18 CBWMV /Page 8 ASPEN BUILDING DEPARTMENT BLOWER DATA CBWMV-24B-040 Blower Performance 0 through 0.80 in.w.g. External Static Pressure Range "ADJUST" Blower Control Jumper Speed Positions Jumper "HEAT" Speed-cfm First Stage"COOL"Speed-cfm Second Stage"COOL"Speed-cfm Setting 1 1 2 3 4 ' 1 2 3 4 ' 1 2 3 4 + 820 990 1180 1340 610 770 930 1010 880 1120 1340 1440 ' NORM 750 900 1070 1230 560 700 830 910 800 1000 1200 1300 670 810 940 1080 510 630 750 810 720 900 1080 1170 CBWMV-36B-070 Blower Performance 0 through 0.80 in.w.g. External Static Pressure Range "ADJUST" Blower Control Jumper Speed Positions Jumper "HEAT" Speed-cfm First Stage"COOL"Speed-cfm Second Stage"COOL"Speed-cfm Setting 1 2 3 14 1 2 13 4 1 2 13 4 + 790 980 1140 1310 590 745 895 975 850 1090 1300 1430 ' NORM 730 870 1040 1190 545 680 805 890 775 990 1190 1280 640 770 920 1070 490 600 725 780 700 870 1065 1150 CBWMV-36C-090 Blower Performance 0 through 0.80 in.w.g. External Static Pressure Range "ADJUST" Blower Control Jumper Speed Positions Jumper "HEAT" Speed-cfm First Stage"COOL" Speed-cfm Second Stage"COOL"Speed-cfm Setting 1 2 3 14 1 2 13 4 1 2 13 4 + 820 1000 1180 1340 620 770 930 1010 890 1130 1340 1450 1 NORM 760 900 1070 1220 570 700 830 910 800 1020 1220 1310 675 810 950 1100 520 630 760 810 720 900 1100 1180 CBWMV-60C-100 Blower Performance 0 through 0.80 in.w.g. External Static Pressure Range "ADJUST" Blower Control Jumper Speed Positions Jumper "HEAT" Speed-cfm First Stage"COOL"Speed-cfm Second Stage"COOL"Speed-cfm Setting 1 2 3 14 1 2 3 14 1 2 3 14 + 1500 1700 1880 2100 1110 1250 1380 1530 1540 1760 1970 2200 1 NORM 1370 1540 1720 1920 1000 1130 1250 1380 1400 1600 1800 1980 1250 1380 1540 1720 930 1040 1130 1260 1270 1420 1600 1780 CBWMV-60C-120 Blower Performance 0 through 0.80 in.w.g. External Static Pressure Range "ADJUST" Blower Control Jumper Speed Positions Jumper "HEAT" Speed-cfm First Stage"COOL"Speed-cfm Second Stage"COOL"Speed-cfm Setting 1 2 3 ' 4 1 2 3 '4 1 2 3 ' 4 + 1510 1720 1900 2120 1100 1250 1400 1560 1570 1800 2000 2200 ' NORM 1380 1560 1740 1920 990 1130 1260 1400 1410 1620 1820 2020 1240 1380 1540 1720 930 1020 1130 1260 1260 1440 1620 1810 1 Factory default jumper setting. NOTES-The effect of static pressure and filter resistance is included in air volumes shown. Fst stage Fan OOOL is approximatelyeeds 70%of the same second stage COOL sped position. RECEIVED Continuous Fan Only speed is approximately 38%of the same second stage COOL speed position. Harmony III TM Zoning System applications-Minimum blower speed: 250 cfm for-24B-40,-36B-070,-36C-090. 450 cfm for-60C-100. 10/0 9/18 380 cfm for 60C-120. Maximum air volume is the same as second stage cool position. Applications with single sided inlets will reduce the air volume by approximately 4%on B-size units and 5%on C-size units. C BUIL_ n RE ? I1 NT HEATING PERFORMANCE CBWMV-24B-040 HEATING OUTPUTS NOTE-Capacities in shaded area require Harmony IIITM Zoning System to reach the air volumes listed Air Heating Outputs At Various Water Temperatures (Btuh) Volume(cfm) 140°F 150°F 160°F 170°F 180°F 190°F 200°F 400 23,700 26,900 30,100 33,500 36,700 39,900 43,100 500 27,400 31,100 34,800 38,800 42,500 46,200 49,900 600 30,700 34,800 38,900 43,500 47,600 51,700 55,900 700 33,600 38,100 42,600 47,600 52,200 56,700 61,200 800 36,200 41,000 45,900 51,400 56,300 61,100 66,000 900 38,500 43,700 48,800 54,800 60,000 65,200 70,400 1000 40,700 46,100 51,600 57,900 63,400 68,900 74,400 1100 42,700 48,400 54,100 60,700 66,500 72,300 78,100 1200 44,500 50,400 56,400 63,400 69,400 75,500 81,500 1300 46,200 52,400 58,500 65,900 72,100 78,400 84,700 CBWMV-36B-070 HEATING OUTPUTS NOTE-Capacities in shaded area require Harmony IIITM Zoning System to reach the air volumes listed Air Heating Outputs At Various Water Temperatures (Btuh) Volume(cfm) 140°F 150°F 160°F 170°F 180°F 190°F 200°F 400 30,300 34,400 38,500 42,700 46,800 50,900 54,900 500 36,200 41,100 45,900 51,100 56,000 60,900 65,700 600 41,500 47,100 52,600 58,700 64,300 69,900 75,500 700 46,300 52,500 58,700 65,600 71,800 78,100 84,300 800 50,700 57,400 64,200 71,800 78,700 85,500 92,400 900 54,600 61,900 69,200 77,600 85,000 92,300 99,700 1000 58,200 66,000 73,700 82,800 90,700 98,600 106,500 1100 61,500 69,700 78,000 87,600 96,000 104,300 112,700 1200 64,600 73,200 81,800 92,100 100,900 109,700 118,500 1300 67,400 76,400 85,400 96,300 105,500 114,600 123,800 CBWMV-36C-090 HEATING OUTPUTS NOTE-Capacities in shaded area require Harmony IIITM Zoning System to reach the air volumes listed Air Heating Outputs At Various Water Temperatures (Btuh) Volume(cfm) 140°F 150°F 160°F 170°F 180°F 190°F 200°F 400 31,400 35,600 39,800 44,100 48,400 52,600 56,800 500 38,000 43,000 48,100 53,400 58,500 63,600 68,700 600 44,000 49,900 55,800 62,000 67,900 73,800 79,700 700 49,600 56,200 62,900 69,900 76,600 83,300 90,000 800 54,800 62,100 69,400 77,300 84,700 92,100 99,400 900 59,600 67,500 75,500 84,200 92,200 100,200 108,300 1000 64,100 72,600 81,200 90,600 99,300 107,900 116,500 1100 68,300 77,400 86,500 96,700 105,900 115,100 124,300 1200 72,200 81,800 91,400 102,300 112,000 121,800 131,500 1300 75,900 86,000 96,100 107,600 117,900 128,100 138,400 CORRECTION FACTOR FOR DIFFERENT INLET AIR TEMPERATURES 60°F Add 6% RECEIVED 65°F No Change 70°F Minus 6% 10/09/18 75°F Minus 12% CBWMV /Page 10 ASPEN BUILDING DEPARTMENT HEATING PERFORMANCE CBWMV-60C-100 HEATING OUTPUTS NOTE-Capacities in shaded area require Harmony IIITM Zoning System to reach the air volumes listed Air Heating Outputs At Various Water Temperatures(Btuh) Volume(cfm) 140°F 150°F 160°F 170°F 180°F 190°F 200°F 700 49,600 56,200 62,900 69,900 76,600 83,300 90,000 800 54,800 62,100 69,400 77,300 84,700 92,100 99,400 900 59,600 67,500 75,500 84,200 92,200 100,200 108,300 1000 64,100 72,600 81,200 90,600 99,300 107,900 116,500 1100 68,300 77,400 86,500 96,700 105,900 115,100 124,300 1200 72,200 81,800 91,400 102,300 112,000 121,800 131,500 1300 75,900 86,000 1 96,100 107,600 117,900 128,100 138,400 1400 79,300 89,900 100,500 112,600 123,400 134,100 144,800 1500 82,600 93,600 104,600 117,400 128,600 139,800 150,900 1550 84,200 95,400 106,600 119,700 131,100 142,500 153,900 1700 88,600 100,400 112,300 126,200 138,200 150,200 162,200 1900 94,000 106,600 119,100 134,100 146,900 159,600 172,400 2100 99,000 112,200 125,400 141,300 154,800 168,200 181,700 CBWMV-60C-120 HEATING OUTPUTS NOTE-Capacities in shaded area require Harmony III TM Zoning System to reach the air volumes listed Air Heating Outputs At Various Water Temperatures(Btuh) Volume(cfm) 140°F 150°F 160°F 170°F 180°F 190°F 200°F 700 55,000 62,400 69,700 77,400 84,800 92,200 99,600 800 61,600 69,800 78,000 86,700 95,000 103,200 111,500 900 67,700 76,700 85,800 95,500 104,600 113,700 122,700 1000 73,500 83,300 93,100 103,800 113,700 123,500 133,400 1100 79,000 89,500 100,100 111,600 122,300 132,900 143,500 1200 84,100 95,400 106,600 119,100 130,400 141,700 153,100 1300 89,000 100,900 112,800 126,100 138,100 150,100 162,100 1400 93,600 106,100 118,600 132,800 145,400 158,100 170,700 1500 98,000 111,100 124,200 139,100 152,400 165,600 178,900 1550 100,100 113,500 126,800 142,200 155,700 169,300 182,800 1700 106,100 120,200 134,400 150,900 165,300 179,700 194,000 1900 113,400 128,500 143,600 161,600 177,000 192,400 207,800 2100 120,000 136,000 152,000 171,300 187,600 203,900 220,300 CORRECTION FACTOR FOR DIFFERENT INLET AIR TEMPERATURES 60°F Add 6% 65°F No Change 70°F Minus 6% 75°F Minus 12% RECEIVED 10/09/18 . ��CN BUIL D k IEPtra.NT REVISIONS Sections Description of Change Optional Accessories Revised Optional Circulating Pump capacity. c Ous Visit us at www.lennox.com JENNOXFor the latest technical information,www.lennoxdavenet.com Contact us at 1-800-4-LENNOX RECEIVED NOTE-Due to Lennox'ongoing commitment to quality,Specifications,Ratings and Dimensions subject to change without notice and without incurring liability.'0/0 9/1 8 Improper installation,adjustment,alteration,service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency. ©2014 Lennox Industries,Inc. ASPEN BUILDING DEPARTMENT STAINLESS STEEL INDIRECT WATER HEATERS Crna® Staideaa Seed %duzect 2Uatez ' P 12 SQUIRE MODELS TO CHOOSE FROM - 6 STANDARD MODELS FROM 30 TO 119 GALLONS - 6 SOLAR MODELS FROM 65 TO 119 GALLONS • 316L PASSIVATED STAINLESS STEEL TANK 316L HIGH CAPACITY STAINLESS STEEL COIL FULLY WELDED CONSTRUCTION ENGINEERED*ASSEMBLED 1NI 111 S � HIGH EFFICIENCY BOILERS&WATER HEATERS o LOChinvari(�/09/18 AS$IEN BUILDING DEPARTMENT Sauire® StabrieddSeed 1od'vzect Vaterz geate't I f - a new Class of Water Heater The Squire Stainless Steel Indirect Water Heater--with 12 models to choose from in capacities from 30-119 gallons, we are sure to have the right size . ' indirect water heater to fit your application. Squire features important enhancements that our customers will recognize and benefit from such as a welded and passivated stainless steel tank and heat exchanger, two-inch thick, high-density insulating foam, and best of all it is designed, engineered and assembled in America. r- Stainless Steel Tank Manufacturing - . Laser Cut Precision A CNC laser uses Programmable Logic Controls to precisely cut the Squire Indirect Water Heater's tank shell out of 14 gauge 316L stainless steel to a tolerance of.01 inch. Tank Cylinder Roller -4-: s The computer controlled tank cylinder rolling machine ensures that the 316L stainless steel is transformed into a geometrically perfect cylinder. Coil Winder Straight tubes are rolled by a seven axis coil winder and turned into a precise,round LASER Cut Precision coil used in the indirect water heater to transfer the BTU's from the heat source to the potable water stored in the tank. Robotic Welder ,, ,,, This state of the art six axis programmable robotic welder uses computer guidance to i _ accurately weld the stainless steel fittings to the tank. Hydrostatic Leak Test I v , _1 - -- After welding,the tank is hydrostatically pressure tested to ensure quality - - conformance. a Passivation Process Each tank is subjected to a soaking spray of I, , ,T L nitric acid.This treatment washes away any • "` iron that was left behind during the welding • , I e.! , '- - process and re-establishes the oxide level of the ' . a - stainless steel to ensure corrosion resistance. Robotic Welder i iI I I _ By removing iron from the welded surfaces,the Squire is less susceptible to corrosion brought it 2 on by aggressive water. U 1 . a Jacket and Foam - t tl I F \ , ,,� :PI The dent resistant polypropylene jacket and %— AO t Ili a ' ') . ' ABS caps are attached to the tank assembly, _ }.a and then high density foam is added using a y:.• Tie highpressure dispensing system to provideaigu l ill\ (...--) insulation that will keep the heat where it belongs, in the water.The result is a tank that is jacketed and evenly foam insulated with Passivated for Protection standby losses as low as 0.5°F per hour. Foam Insulation PrdcEV 0 9/ NES - y 2 ASPEN . „AMEN& BUILDING DEPARTMENT Outstanding Features - Six Standard Models from 30 to 119 Gallons 316L Passivated Stainless Steel Tank The highest quality indirect water heater in the market also has 316L Stainless Steel material is used for the tank interior for one of the widest ranges of gallon capacities. With 6 models superior durability and long life. The rust prohibitive characteristics covering gallon capacities from 30 to 119 gallons the Squire is of this material make it the perfect material to resist the corrosive one of the broadest lines available. tendencies of domestic water. The passivation process consists of a treatment method that enhances and increases the superior Six Solar Models from 65 to 119 Gallons corrosion resistance of stainless steel. With three dual coil models for solar heating in conjunction with a heat source and three models with a solar coil and an electric 316E High Capacity Stainless Steel Coil element the Squire line of water heaters has a model to fit any The Squire's 316L Stainless Steel heating coil efficiently transfers high residential or light duty commercial solar application. volumes of BTU's from the heat source to the domestic water with high first hour delivery capability. 100%Stainless Steel Construction Squire Water Heaters are constructed with Stainless Steel Designed, Engineered and Assembled in the USA materials that are highly resistant to corrosion that can result A 100%stainless steel indirect water heater built in the USA, from poor water quality. the Squire is completely assembled in Lebanon, Tennessee. Inside Look How it Works Dent resistant polypropelene jacket* Temperature Stainless Steel SIT Indirect \itill11.1111:7&pressure The Squire uses the power and efficiency of the relief valve building's heating boiler or solar array to generate IIII domestic hot water for showers, dishwashing, clothes Boiler Sensor washing or any potable hot water demand. The water inlet well efficiency of the heating boiler could be as much as 20% higher than a direct-fired tank-type water heater. So,why 316E not use that efficiency to "indirectly" provide hot water for Stainless all potable applications? Steel coil By using the Squire to indirectly heat the domestic water,you Boiler water eliminate the additional gas line,electrical connections and vent ducts needed with direct-fired tank-type water heaters. outlet density foam ........... _ insulation Cold water /High inlet --------)46Q600.4 *SET models feature metal jacket VOW, • . icital • ' -., .... -'- I se' e ' 1 • r� ill 111111P 1. c : r #1, 41 . Combine the Knight Heating Boiler with the Squire Indirect for the perfect combination for di: your appliccn. 1 U/U 9/18 3 ASPEN BUILDING DEPARTMENT Fully Welded Construction T&P Relief Valve Lochinvar utilizes state of the art, highly accurate robotic Supplied with the unit in the carton. (shipped loose) welding equipment that results in a fully welded construction method that requires no gaskets or mechanical sealing High Density CFC/HCFC Free Polyurethane Foam methods. Gaskets and seals are the weak point of any water Two inches of R-13.4 High Density Polyurethane foam yields storing appliance, therefore Lochinvar's advanced design the lowest standby losses in the industry. eliminates this potential failure point. Attractive Rust Resistant Jacket Factory Supplied Tank Sensor (SIT and SDT only) Resistant to scratches and dents, the Squire will maintain its A tank sensor with built in temperature limit is standard classic high quality appearance for years. 1 equipment on all sizes. This sensor accurately monitors the • water temperature and sends a call for heat when the tank Limited Lifetime Warranty* temperature drops below the desired setpoint. This sensor Lochinvar believes that the Squire is the best built Indirect is 100%compatible and can be directly connected with Water Heater on the market, we have a Limited Lifetime Lochinvar's line of KNIGHT or Cadet Heating Boilers. warranty to prove it. *SIT models only — • Solar Indirect with SDT Dual Coil Solar Indirect with SET Electric Back-up Squire Indirect Water Heaters with a dual coil design Squire Indirect Water Heaters with a single coil and have a coil in the lower portion of the tank to transfer an electric element are designed to collect heat from heat from a solar array to the water that is stored in a solar array and transfer the collected heat into the tank. the stored water by way of the indirect coil which is located in the lower portion of the tank. - An additional coil in the upper portion of the tank - • will transfer heat from a back-up boiler into the An electric element,which is controlled by a factory water. This will ensure that the tank has ample hot supplied thermostat, is positioned in the top half of water even at times when the solar array cannot the tank to ensure ample hot water even at times generate enough heat to suitably heat the tank. when the solar array is not capable of collecting the _ heat required by the DHW demand. Trillilr L.:1111111.1?Lo..4. ;r • 0 i. '41 .4 ailyi leS II ll - REC ! a loilin l & ASPEN BUILDING DEPARTMENT Stainless Steel Indirect SIT Models Dimensions and Specifications "') O HOT WATER UTLET EID RELIEF VALVE (shipped loose) A BOILER z25=\ N IN s 45° D \ SENSOR WELL G BOILER OUT The"Hot Water Outlet"connection is Female NPT. H I All other connections are Male NPT. COLD WATER INLET Domestic Coil Model Water Connection Shipping Number A B D G H I Conn. Size Wt. (lbs.) SIT030 39-1/2" 20" 32-1/4" 21-3/4" 8-1/4" 3" 1" 1" 79 SIT040 55-3/4" 20" 48-1/2" 25-1/4" 8-1/4" 3" 1" 1" 105 SIT050 48" 24" 39-3/4" 24-1/2" 9-1/4" 3-3/4" 1" 1" 131 SIT065 60" 24" 52-1/4" 28" 9-1/4" 3-1/4" 1-1/2" 1" 147 SIT080 69-1/2" 24" 61-3/4" 28" 9-1/4" 3-1/4" 1-1/2" 1" 177 SIT119 69" 28" 60-1/4" 31-3/4" 9-1/4" 3-1/4" 1-1/2" 1" 213 Heat Source Standby First Continuous 1st Hour Min. Flow Friction Model Capacity Water Volume Loss Draw Delivery Delivery Coil Load Rate Loss Number (Gallons) (Gallons) (°F/Hr) Gals. (GPH) (Gallons) (Btu/Hr) (GPM) (Ft. Hd.) SIT030 27 1.1 1.5 24 160 184 99,000 14.0 3.9 SIT040 40 1.6 0.9 27 181 208 115,000 14.0 4.5 SIT050 52 1.7 0.9 45 210 255 133,000 14.0 5.3 SIT065 67 1.9 0.7 65 263 328 154,000 14.0 5.7 SIT080 82 2.1 0.6 74 266 340 160,000 14.0 5.7 SIT119 113 3.2 0.5 109 308 418 199,999 14.0 6.5 Performance data is based on IWH-TSI test results.All ratings are based on 180°F boiler water temperature with incoming cold water at 58°F and a Delta T of 77°F. Includes tank sensor for use with KNIGHT or Cadet Heating Boiler. Optional thermostat available for use with other boiler models. SIT MODELS All models standard with a Lifetime Limited Warranty Against Tank Failure. All parts are warranted for one year. Five year limited tank warranty on all AMC ® S p e) models when installed in a commercial ram■■��CERTIFIED V 1• www.n.�ao-.mow.ore r E 9VE application. C UR 10/09/18 ASPEN BUILDING DEPARTME Solar Stainless Steel Indirect Dimensions and Specifications B _13 HOT WATER FROM HOT WATER OUTLET cILER OUTLET BOILER 'Iw = 0 RELIEF VALVE SENSOR (sM1ippea loose) WELL RELIEF VALVE F TO (shipped loose) 4° -22.5°45° L BOILER / T-22.5° 45° A FROM A PANEL FR PANOEL M D ® E SOLAR SOLAR • SDT Models F SENSOR SET Models WELL G G TO TO PANEL L PANEL/ L{ H 1 1 1 1 1 1 �- f COLD WATER COLD WATER INLET INLET The"Hot Water Outlet"connection is Female NPT. SDT Models Dimensions and Specifications All other connections are Male NPT. Domestic Coil Model Water Connection Shipping Number A B D E F G H I Conn. Size Wt.(lbs.) SDT065 60" 24" 52-1/4" 47-1/4" 33-3/4" 28" 9-1/4" 3-1/4" 1-1/2" 1" 158 SDT080 69-1/4" 24" 61-3/4" 53-3/4" 40-1/4" 28" 9-1/4" 3-1/4" 1-1/2" 1" 188 SDT119 68" 28" 60-1/4" 54-1/2" 37-1/2" 31-3/4" 9-1/4" 3-1/4" 1-1/2" 1" 224 Heat Boiler Heat Standby Continuous 1st Hour Min. Flow Friction Model Capacity Source Water Source Water Loss Delivery Delivery Coil Load Rate Loss Number (Gallons) (Gallons) (Gallons) (°F/Hr) (GPH) (Gallons) (Btu/Hr) (GPM) (Ft. Hd.) SDT065 66 2.1 1.7 0.7 175 205 128,000 14.0 3.4 SDT080 79 2.1 1.7 0.6 175 208 128,000 14.0 3.4 SDT119 110 3.2 2.6 0.5 251 301 181,000 14.0 4.9 Performance data based on incoming cold water at 50°F and a Delta T of 77°E Delivery ratings for boiler coil only.Includes tank sensor for use w/KNIGHT Heating Boiler. SET Models Dimensions and Specifications Domestic Coil Model Water Connection Shipping Number A B D G H I Conn. Size Wt. (lbs.) SET065 60" 24" 52-1/4" 28" 9-1/4" 3-1/4" 1-1/2" 1" 149 SET080 69-1/2" 24" 61-3/4" 28" 9-1/4" 3-1/4" 1-1/2" 1" 179 SET119 68-1/4" 28" 60-1/4" 31-3/4" 9-1/4" 3-1/4" 1-1/2" 1" 215 Electric Electric Heat Source Standby Continuous 1st Hour SET&SDT MODELS Model Capacity Water Loss Delivery Delivery All models standard with a 5 year Number (Gallons) (Gallons) (°F/Hr) (GPH) (Gallons) Limited Warranty Against Tank Failure. All parts are warranted for one year. SET065 67 1.9 0.7 24 54 SET080 81 2.1 0.6 24 57 SET119 113 3.2 0.5 24 75 All SET models:4500w 240v 1 phase. tECEI Alt— E $ p �' C> Lochinvar,LLC l �/ �����' 300 Maddox Sim son Parkwa qt.aL .,\ I J`'��t I■\�/ ebon,Tennessee 37090 s A® V �" 10/0 9 - ���11111111\\\\ Dili�7 P:615.889.8900/F:615.547.1000 HIGH EFFICIENCY BOILERS&WATER HEATERS C us *SET models on. LOW LEAD n©®0 Lochinvar.com y CONTENT SIT-02(Reprint SIT-02 10/15) (Website Update 9/16 PDP-l0M-5/16—Print d to I'.`S..`'. •II I' 'b • STAINLESS STEEL LOthlflVar® INDIRECT WATER HEATE HIGH EFFICIENCY BOILERS&WATER HEATERS Submittal Sheet SIT-Sub-02b STAINLESS STEEL INDIRECT WATER HEATERS JOB NAME LOCATION ARCH./ENGR. WHOLESALER MECH. CONTRACTOR MODEL NO. GALLON CAPACITY NOTES Standard Features Optional Equipment •Fully Welded Construction Place an X in the box by all options that apply •100% Stainless Steel Construction ❑Aqua Stat •Built in U.S.A. at Lochinvar World Headquarters •316L Passivated Stainless Steel Tank •316L Stainless Steel Heating Coil •1"Boiler Supply and Return Connections •1"Domestic Water Connections(30,40, 50 models) •1-1/2"Domestic Water Connections(65, 80, 119 models) •Non-HCFC High Density Foam Insulation •Temperature and Pressure Relief Valve(Shipped Loose) •Factory Supplied Tank Sensor •Warranty- Limited Lifetime Five year limited tank warranty on all models when used in a commercial application. One year warranty on parts. (See warranty for details) RECEIVED 10/09/18 ASPEN BUILDING DEPARTMENT Stainless Steel Indirect Water Heater Dimensions & Specifications B -{ )11 HOT WATER OUTLET i RELIEF VALVE (shipped loose) A BOILER 225°- IN NI 5° D \ SENSOR WELL G BOILER OUT HI11 limmi COLD WATER INLET Domestic Coil Model Water Connection Shipping Number A B D G H I Conn. Size Wt. (lbs.) SIT030 39-1/2" 20" 32-1/4" 21-3/4" 8-1/4" 3" 1" 1" 79 SIT040 55-1/2" 20" 48-1/2" 25-1/4" 8-1/4" 3" 1" 1" 105 SIT050 47" 24" 39-3/4" 24-1/2" 9-1/4" 3-3/4" 1" 1" 131 SIT065 60" 24" 52-1/4" 28" 9-1/4" 3-1/4" 1-1/2" 1" 147 SIT080 69-1/2" 24" 61-3/4" 28" 9-1/4" 3-1/4" 1-1/2" 1" 177 SIT119 68-1/4" 28" 60-1/4" 31-3/4" 9-1/4" 3-1/4" 1-1/2" 1" 213 Heat Source Standby First Continuous 1st Hour Min. Flow Friction Model Capacity Water Volume Loss Draw Delivery Delivery Coil Load Rate Loss Number (Gallons) (Gallons) (°F/Hr) Gals. (GPH) (Gallons) (Btu/Hr) (GPM) (Ft. Hd.) SIT030 27 1.1 1.5 24 160 184 99,000 14.0 3.9 SIT040 40 1.6 0.9 27 181 208 115,000 14.0 4.5 SIT050 52 1.7 0.9 45 210 255 133,000 14.0 5.3 SIT065 67 1.9 0.7 65 263 328 154,000 14.0 5.7 SIT080 82 2.1 0.6 74 266 340 160,000 14.0 5.7 SIT119 113 3.2 0.5 109 308 418 199,999 14.0 6.5 Performance data is based on IWH-TS1 test results.All ratings are based on 180°F boiler water temperature with incoming cold water at 58°F and a Delta T of 77°F. Includes tank sensor for use with KNIGHT Heating Boiler. Optional thermostat available for use with other boiler models. Lochinvar,LLC 7ILOCIliJIVarOO 300 Maddox Simpson Parkway Ai! CERTIFIED RECEIVED_ A®P:615.889.8900/F:615.547.1000 ...._^. �I1• ,\�' / v • O HIGH EFFICIENCY BOILERS&WATER HEATERS ri©®0 Lochinvar.com LOVV LE. CONTENT, (Website Update 9/16) 10/15—Printed in U.S.A. ASPEN BUILDING DEPARTMENT . , .," Panasonic w .., I W h s erGreen eCeet'M VENTILATION FAN • 4 FV-05-11VKS1, FV-05-11VK1, FV-11-15VK1 . iO -- �1 Most Efficient ®2016 �� www, !i 4 FV-05-11VKSL1, FV-05-11 VKL1, FV-11-15VKL1 s-. a - 0 •Customizable, all-in-one fan and fan/LED light combinations •Pick-A-Flow speed selector—one fan,you choose the CFM •Unique Plug 'N Play modules provide up to three value-added features •Revolutionary DC motor with SmartFlow'M technology ensures optimal J 4N. •CFM output Replaceable, GU24 base LED lamps provide warm, energy efficient illumination •Flex-Z Fast''bracket provides flexible,fast and easy installation • •Can be used to comply with ASHRAE 62.2, LEED,CALGreen and ENERGY STAR for Homes 3.0 ,DDITIONAL BENEFITS •Integrated dual 4"or 6"duct adaptor(up to 110 CFM models) •Built-in metal flange provides blocking for penetrations through drywall as an air barrier,and assists with the decrease in leakage in the building envelope during blower door testing ALPNAsvNi • •Fits in 2 x 8 construction Q 5:1) •Protected by UL Class 2 Power Unit v w ADJUSTABLE AIRFLOW FOR •UL listed for tub/shower enclosure when used with a GFCI protected circuit J MAXIMUM PERFORMANCE •6 year warranty on DC motor,5 years on LED,3 years on parts o''yANCE9. .-�'°'fvi v a A ivA 1D 2115 VED C /Green PARTNER OF THE YEAR Sustained tillP( /18 ******6YEARS INA ROW 'L_N BUILDING DEPARTMENT I ONE FAN - ENDLESS POSSIBILITIES. The all-purpose, customizable IAQ solution for virtually any application WhisperGreen Select"is a ground-breaking IAQ solution that is revolutionizing the ventilation fan industry with a new set of features that enable customization and easier installation.To the builder and professional installer, Panasonic continues to be the innovation leader O with high performance ventilation solutions that are built to last.WhisperGreen Select's unique design and superior energy efficiency are achieved through engineering expertise, provided by a company who sets the standard for quality and value. WHISPERGREEN SELECT' IS AS EASY AS 1-2-3! Step 1: Select a Base Fan Model Select a base model to start building the perfect IAQ solution that satisfies your ventilation design requirements. Fan Fan/Light FV-05-11 VKS1:30 to 110 CFM integrated multi-speed FV-05-11 VKSL1:30 to 110 CFM integrated multi-speed+LED Light FV-05-11VK1:50-80-110 CFM single speed FV-05-11VKL1:50-80-110 CFM single speed+LED Light FV-11-15VK1: 110-130-150 CFM single speed FV-11-15VKL1: 110-130-150 CFM single speed+LED Light Pick-A-Flow'"Speed Technology Built-in Pick-A-Flow'"speed selector-one fan,you choose the CFM. Provides the unique ability to select your required airflow(50-80-110 and 110-130-150 CFM models)with the simple flip of a switch. Step 2: Select Value Added Features* WhisperGreen Select"offers a unique set of Four*patented modules that allow you to further customize your fan: Multi-Speed with Time Delay(FV-VS15VK1)-Allows you to select the proper CFM settings to satisfy ASHRAE 62.2 continuous * ventilation requirements.The fan runs continuously at a pre-set lower level,then elevates to a maximum level of operation when the wall switch is turned on,or when the SmartAction®motion sensor or condensation sensor module is activated.A high/Low delay timer returns the fan to the pre-set CFM level after a period of time set by the user. 1) O SmartAction®Motion Sensor(FV-MSVK1)-Automatically activates when someone enters the room.Once the settings have been applied,the fan becomes truly automatic, making it ideal for people with disabilities and assisted living environments such as nursing homes and retirement communities.This module also activates an automatic 20 minute delay off timer for the fan. Condensation Sensor(FV-CSVK1)-Helps control bathroom condensation to prevent mold and mildew.Advanced sensor 4 technology detects relative humidity and temperature to anticipate dew point,automatically turning the fan on to control humidity. Built-in Relative Humidity(RH)sensitivity adjustment enables fine tuning for moist conditions and for satisfying CALGreen requirements. q.t . When the condensation sensor is used in conjunction with multi-speed functionality,the fan will kick up to high speed when the condensation sensor detects moisture in the room.This module also activates an automatic 20 minute delay off timer for the fan. I Ar NiteGlow'"LED Night Light(FV-NLVK1)-A specialized photocell feature automatically turns on the 1 watt LED night light when darkness is sensed in the room. Hi/Low brightness switch enables you to fine tune the photo cell to work in conjunction with the darkness level of your bathroom.This module also activates an automatic 20 minute delay off timer for the fan. *Select up to 3 value added features. Step 3: Install Your Ideal Fan with the New! Flex-Z Fast- Installation System iplijiliIngeniously designed installation _� bracket provides flexible,fast and easy - installation for all your new construction or renovation projects. Fold up articulating joints to easily Fold articulating joints back down Extend bracket to desired length. position bracket in between the in preparation for installation joist and/or through ceiling hole. Installed Performance and Quiet Operation at 0.25"w.g.Static Pressure R�•CEIV6 ASHRAE, ENERGY STAR®, LEED for Homes, and HVI have set the industry standard for performance measurement�a�l .g. WhisperGreen Select'"fans not only provide powerful CFM output at 0.25"w.g., but our sones have also been certified at 0.21'Va✓.1O 9/18 so they are quiet under pressure and after installation. ASPEN BUILDING DEPARTMENT I W h s rGree11SeCeet VENTILATION':FAN OFV-05-11VK1 FV-11-15VK1 0.80 0.80 a r-es4 1 0.70 ono e 0.60 : 0.60 ismFm a \ - n -uo CFM icocrm 0.30 'y BOCFm ° -IN CFM y 0.50eocFmi' 0.50 �, -110 CFM 7n 0.40 - �i 0.40 100 CFM 0.30 -00CFM 0.20 0.20 0.10 010 \ 0.00 0.00 0 20 40 60 80 100 120 0 50 100 150 200 Airflow(CFM) Allow(CFrq WhisperGreen Select (Fan Only Models) WhisperGreen S Base Fan Base Fan will SPECIFICATIONS FV-05-11VK1 FV-11 5VK1 Static Pressure in inches w.g. 0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.25 AirVolume(CFM) 110 113 80 82 50 53 150 151 130 130 110 110 110 113 100 106 90 95 80 82 Noise(sones) <0.3 0.8 <0.3 0.4 <0.3 <0.3 <0.3 0.7 <0.3 0.5 <0.3 <0.3 <0.3 0.8 <0.3 0.7 <0.3 0.6 <0.3 0.4 Power Consumption(watts) 9.8 16.1 5.4 10.2 3.2 6.5 12.7 21.7 9.5 16.8 6.6 12.7 9.8 16.1 8.0 14.0 6.5 11.7 5.5 10.2 Characteristics _ (HVI tested data Energy Efficiency(CFM/Watt) 11.5 7.2 15.3 8.4 15.1 8.1 11.5 6.8 13.1 7.8 15.7 8.2 11.5 7.2 13.0 7.9 14.5 8.5 15.3 8.4 for 0.1"S.P.) Speed(RPM) 931 1205 814 1131 747 1072 664 904 635 891 616 889 931 1205 895 1179 852 1146 814 1131 Current(amps) 0.10 0.16 0.06 0.10 0.04 0.07 0.13 0.21 0.10 0.17 0.07 0.13 0.10 0.16 0.09 0.14 0.07 0.12 0.06 0.10 MAX.Current(amps) 0.27 0.33 OPower Rating(V/Hz) 120/60 120/60 Motor Type DC DC Type of Motor Bearing Ball Ball Specifications Thermal Fuse Protection Yes Yes Blower Wheel Type Sirocco Sirocco ENERGY STAR Qualified Yes Yes Duct Diameter(Inches) 4&6 6 Installation Mounting Opening(Inches sq.) 10-1/2 10-1/2 Grille Size(Inches sq.) 13 13 Lamp Watts N/A N/A Lumens Om) N/A N/A Lumens Per Watt(LPW) N/A N/A Color Rendering Index N/A N/A Light Specifications Color Temperature(Kelvin) N/A N/A Rated Life(hours) N/A N/A Lamp Model# N/A N/A Type of Lamp Socket N/A N/A Night Light Specs Night Light Watts N/A* N/A' Shipping Gross Weight(Ibs) 11.90 13.45 UL tub/Shower Enclosure Yes Yes Approved Cade/Standard/ Washington VIAQ Code Yes Yes Regulation California Title 24Compliant Yes Yes Mfg in ISO 9001 Certified Facility Yes Yes *Light specs may change. **Night GIs"LED Night Light module is available. O NOTE:0.25"w.g.=Installed Performance PRT Flo DC Motor with SmartFlow""Technology IVED 0,, D^ 4-= WhisperGreen Select'""features the same revolutionary DC motor that comes with our WhisperGre pro ucts. �r With built-in SmartFlow-technology,WhisperGreen Select'""is designed to perform as rated.When the fir ern/18 ��oc' \ static pressure, its speed is automatically increased to ensure optimal CFM output.This feature provides peace of mind, as the installer doesn't have to worry about compromising the fan's performance. ASPEN BUILDING DEPARTMENT WhisperGreen Select Ventilation Fans FV-05-11 VK1 FV-11-15VK1 FV-05-11VKS1 , elect (Fan Only Models) WhisperGreen Select (Fan Only Models) h Integrated Multi-Speed Base Fan with Multi-Speed Plug'N Play Module -05-11VKS1 FV-11-15VK1 +FV-VS15VK1 0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.25 70 71 60 66 50 53 40 43 30 33 150 151 130 130 120 121 110 110 100 102 90 96 80 84 70 72 60 62 50 51 <0.3 0.4 <0.3 <0.3 <0.3 0.3 <0.3 <0.3 <0.3 <0.3 <0.3 0.7 <0.3 0.5 <0.3 0.4 <0.3 <0.3 <0.3 <0.3 <0.3 <0.3 <0.3 0.4 <0.3 0.4 <0.3 0.4 <0.3 0.4 4.3 8.6 3.6 7.8 3.2 6.5 2.7 5.7 2.4 5.0 12.7 21.7 9.5 16.8 7.4 14.1 6.6 12.7 5.6 11.3 4.9 10.7 4.4 9.6 3.8 8.6 3.6 7.7 3.1 6.8 17.2 8.7 17.5 8.8 15.1 8.1 16.3 8.2 14.2 7.6 11.5 6.8 13.1 7.8 16.2 8.6 15.7 8.2 17.9 9.0 18.6 9.0 18.2 8.8 18.4 8.4 16.7 8.1 16.1 7.5 772 1112 750 1107 747 1072 731 1073 718 1062 664 904 635 891 615 884 616 889 603 886 595 891 604 911 602 918 622 919 616 928 0.05 0.09 0.04 0.08 0.04 0.07 0.08 0.06 0.03 0.06 0.13 0.21 0.10 0.17 0.08 0.14 0.07 0.13 0.06 0.11 0.06 0.11 0.05 0.10 0.05 0.09 0.04 0.08 0.04 0.07 0.27 0.33 120/60 120/60 DC DC Ball Ball Yes Yes Sirocco Sirocco Yes Yes 4&6 6 10-1/2 10-1/2 13 13 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A' N/A' 11.90 13.45 Yes Yes Yes Yes Yes Yes Yes Yes LED Lighting �`VFD WhisperGreen Select"fan/light models feature a contemporary flush mount grille that incor r o replacea e, ENERGY STAR rated, 7W GU24 base LED lamps. Panasonic's advanced LED technology lasts 41r091 0 .,111h81 compact fluorescent lamps and does not contribute to mercury waste when disposed. ASPEN BUILDING DEPARTMENT _ T !s e 'GreenS e eet" ILATIONN FV-05-11 VKL1 FV-11-15VKL1 0.80 0.80 3 3 § 0.70 1 0.70 g -u�m-spaa a�a • i 0.80, -rraru 3 0.60 -Mud dg -speea aa 11L, rti / _`\ -ioocru k -NC. 'p -rao cru 0.50 eocru p 0.50 -IRO CM - S //� 0.40 \� 0.40 %/, _ ,m CM _ ', 0.30 -sacra 0.30 / soda, _ -- 0.20 :44 0.20 0.10 0.10 -60crm 0 20 40 60 80 100 120 0 50 100 150 200 Airflow(CFrq Airrow(OFM) WhisperGreen Select(Fan/LED Light Models) WhisperGreen Sele SPECIFICATIONS Base Fan with LED Light Base Fan with LED Li FV-05- 1VKL1 FV-11- 5VKL1 Fir Static Pressure in inches w.g. 0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.25 Air Volume(CFM) 110 114 80 86 50 53 150 143 130 131 110 111 110 114 100 105 90 94 80 86 Noise(sones) 0.4 0.9 <0.3 0.6 <0.3 <0.3 0.6 0.9 <0.3 0.8 <0.3 0.6 0.4 0.9 <0.3 0.8 <0.3 0.6 <0.3 0.5 Power Consumption(watts) 11.1 18.0 6.0 11.1 4.0 7.0 16.5 24.0 12.0 21.0 8.5 16.0 11.1 17.6 8.7 15.0 7.0 12.8 5.8 11.1 Characteristics (HVI tested data Energy Efficiency(CFM/Watt) 9.9 6.3 13.3 7.7 12.8 7.7 9.2 6.0 10.9 6.3 13.1 7.1 9.9 6.3 11.6 7.1 13.1 7.5 13.3 7.7 for 0.1"S.P.) Speed(RPM) 960 1237 837 1157 740 1081 730 941 679 926 652 914 960 1237 926 1213 872 1184 837 1157 Current(amps) 0.12 0.17 0.07 0.12 0.04 0.07 0.16 0.22 0.12 0.19 0.08 0.15 0.12 0.17 0.09 0.15 0.08 0.13 0.07 0.12 MAX.Current(amps) 0.42 0.48 Power Rating(V/Hz) 120/60 120/60 Motor Type DC DC Type of Motor Bearing Ball Ball Specifications Thermal Fuse Protection Yes Yes Blower Wheel Type Sirocco Sirocco ENERGY STAR Qualified Yes Yes Duct Diameter(Inches) 4&6 6 Installation Mounting Opening(Inches sq.) 10-1/2 10-1/2 Grille Size(Inches sq.) 13 13 Lamp Watts 2x7W 2x7W Lumens Om) 5501m per lamp* 5501m per lamp* Lumens Per Watt(LPW) 80LPW* 80LPW* Color Rendering Index >80 >80 Light Specifications Color Temperature(Kelvin) 3000K 3000K Rated Life(hours) 40,000 40,000 Lamp Model# LPHT7 LPHT7 Type of Lamp Socket GU24 GU24 Night Light Specs Night Light Watts N/A** N/A** Shipping Gross Weight(Ibs) 14.55 14.77 UL tub/Shower Enclosure Yes Yes Approved Code/Standard/ Washington VIAQ Code Yes Yes Regulation California Title 24 Compliant Yes Yes Mfg in ISO 9001 Certified Facility Yes Yes *Light specs may change. **Night GIo7"LED Night Light module is available. NOTE:0.25"w.g.=Installed Performance RECEIVED 10/09/18 ASPEN BUILDING DEPARTMENT FV-05-11 VKL1 FV-11-15VKL1 FV-05-11 VKSL1 O e ,, LL lull 11 •• ' 7.:7,' <7:,:%%0>',:> ' 11(111/Pr:7 2' ct (Fan/LED Light Models) 111 Illi WhisperGreen Select (Fan/LED Light Models) ight and Integrated Multi-Speed Base Fan with LED Light and Multi-Speed Plug'N Play Module 05-11VKSL1 FV-11-15VKL1 +FV-VS15VK1 0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.25 70 71 60 62 50 53 40 43 30 35 I 150 143 130 131 120 122 110 111 100 102 90 90 80 82 70 71 60 62 50 52 <0.3 0.4 <0.3 0.3 <0.3 <0.3 <0.3 <0.3 <0.3 <0.3 0.5 0.9 <0.3 0.8 <0.3 0.6 <0.3 0.6 <0.3 0.5 <0.3 0.4 <0.3 0.4 <0.3 0.3 <0.3 0.3 <0.3 0.4 4.7 8.9 3.9 7.6 1 3.2 6.6 2.8 5.7 2.5 5.0 1 16.4 23.3 11.5 19.6 9.5 16.9 7.9 14.8 6.9 13.5 5.7 11.6 5.0 10.4 4.3 8.8 4.0 7.9 3.2 7.2 15.3 8.2 15.9 8.4 12.8 7.7 14.6 7.7 12.8 7.4 9.2 6.0 10.9 6.3 12.8 7.3 13.1 7.1 14.8 7.7 16.0 7.8 16.0 7.9 16.3 8.1 15.5 8.1 16.3 7.5 796 1119 769 1102 1740 1081 1739 1077 731 1058 730 941 679 926 669 917 652 914 644 923 631 917 633 918 624 904 634 910 607 928 0.05 0.09 0.05 0.08 0.04 0.07 0.04 0.06 0.03 0.06 0.16 0.22 0.12 0.19 0.10 0.17 0.08 0.15 0.07 0.14 0.06 0.12 0.06 0.11 0.05 0.09 0.05 0.08 0.04 0.08 0.42 0.48 120/60 120/60 O DC DC Ball Ball Yes Yes Sirocco Sirocco Yes Yes 4&6 6 10-1/2 10-1/2 13 13 2x7W 2x7W 1501m per lamp* 5501m per lamp* 80LPW* 80LPW* >80 >80 3000K 3000K 40,000 40,000 LPHT7 LPHT7 GU24 GU24 N/A** N/A** 14.33 14.77 Yes Yes Yes Yes Yes Yes Yes Yes Q•• ° Panasonic Eco Solutions of North America For Order Information J /® \ V; Eco Products Division PHONE:866-292-7299 Id EC E'l V ® V! ±;•yt ' Two Riverfront Plaza FAX:888-553-0723 \ �� C US CERTIFIED D �i •j Newark, NJ 07102 ventfans@us.panasonic.co ans 18 Scan code to view . anasonic.com/ventfans O/O /us.panasonic.com/ventfans Select animation p Design and specifications subject to change without notice. U,E8V0fi56 BUILDING DEPARTMENT 0_ 'c FV-05-11 VK1 W.,- h P r G ree nselCeet Adjustable Airflow for Maximum Performance VENTILATION'.FAN Specification Submittal Data /Panasonic Ventilation Fan Description Customizable Ventilation Fan shall be low sone ceiling mount rated for continuous 411 or 61' duct run. Fan shall be ENERGY STAR®rated and certified by the Home Ventilating Institute (HVI).Evaluated by Underwriters Laboratories and conform to both UL and cUL safety standards. Motor/Blower: •Enclosed DC brushless motor technology rated for continuous run. •Fan ventilation rates shall be manually adjustable for 50-80-110 CFM. 0vo '_ •Power rating shall be 120 volts and 60 Hz. •Fan shall be UL listed for tub/shower enclosure when used with a GFCI protected � ' circuit and used in insulated ceiling(TYPE IC.). ��' ` •Fan equipped with a thermal cutoff fuse �- Ili--III .�`` ; _ •Removable,permanently lubricated,plug-in motor. -__- % / • '4 Housing: •Rust proof epoxy and polyester resin coating,26 gauge galvanized steel body. ,✓z •Integrated dual 4"or 6"diameter duct adapter. ' •Built-in metal flange provides blocking for penetrations through drywall as an Air - 7 Barrier,and assists with the decrease in leakage in the Building Envelope during ., 1411141000. blower door testing. •Built in backdraft damper. •Articulating and expandable installation bracket up to 24". Grille: \ �� •Attractive design using Poly Pro material. •Attaches directly to housing with torsion springs. •Includes a motion sensor cap for use as a cover when motion sensor Plug'n PlayTM module has not been selected. Warranty: •ALL Parts:3 Years from original purchase date. DC Motor:6 Years from original purchase date. Architectural Specifications: FV-05-11 VK1 Customizable Ventilation Fan shall be ceiling mount, ENERGY STAR®rated type with built-in speed selector. Select from 50/80/110 CFM and no more than<0.3 sone as certified by the Home Ventilating Institute(HVI)at 0.1 w.g.with no less than 53/82/113 CFM and no more than<0.3/0.4/0.8 sones at.25 w.g.Power Consumption shall be no Performance Curve 4"or 6"duct greater than 3.2/5.4/9.8 watts at 0.1 w.g.and 6.5/10.2/16.1 watts at 0.25 w.g.ENERGY 0.80 STAR®rated with efficiency of no less than 15.1/15.3/11.5 CFM/watt at 0.1 w.g.and than 8.1/8.4/7.2 CFM/watt at 0.25 w.g. The motor shall be enclosed with brushless , 070 DC motor engineered to run continuously.DC motor speed shall automatically increase _ „ ,. .. when the fan senses static pressure to maintain selected CFM. Power rating shall be a oso =� „ ,00CF 120v/6OHz. Duct diameter shall be no less than 4", inclusive of an integrated dual 4" 0.50 ,_ — or 6"duct adapter. Plug 'N PIayTM modules provide up to three additional features. _.,,-,_ —,OCFM Select from Multi-Speed with Time Delay, Condensation Sensor, LED Night Light and 040 -,,.,,-,\ —50CFM Motion Sensor. Fan shall be UL and cUL listed for tub/shower enclosure when used �' 50CFM with a GFCI protected circuit. Fan can be used to comply with ASHRAE 62.2, LEED, oso =B11. 1111 —30CFM ENERGY STAR®IAP,EarthCraft,California Title-24 and WA Ventilation Code. 0.20 ,��,,.��� DC Motor Technology: ow When fan senses static pressure,its speed is automatically increased to .Y' F4°4, ensure that the desired CFM is not compromised,which allows the fan y 000 0 20 40 60 80 100 120 !! - to perform as rated. DC 1 Model Quantity Comments Project: Location: Architect: Engineer: Contractor: RECEIVED Submitted by: Date: 10/09/18 For complete Installation Instructions visit us.panasonic.com/ventfans ASPEN BUILDING DEPARTMENT Qp$ASO41 Wh _____� Q Q/ 4 S D rG ree I eCect AdjustableAirflow for FV-05-11 VK1 V` Maximum Performance VENTILATIONFAN Plug 'N PlayTM Modules Plug 'N Play-modules provide up to three additional features.Select from Multi-Speed with Time Delay, Motion Sensor,Condensation Sensor and LED Night Light. FV-VS15VK1: Multi-Speed with Time Delay illi Allows you to select the proper CFM settings to satisfy ASHRAE 62.2 continuous ventilation requirements. The fan runs continuously at a pre-set lower level(0,30-100 CFM,in 10 CFM increments),then elevates to a maximum level of operation (50-80-110 CFM)when the wall switch is turned on,or when the motion sensor or Condensation Sensor module is activated. A High/Low delay timer returns the fan to the pre-set CFM level after a period of time set by the user. FV-MSVK1: Motion Sensor 0�ZAI Automatically activates when someone enters the room.Once the settings have been applied,the fan becomes truly automatic. This module also activates a 20 minute delay off timer for the fan. 0 FV-CSVK1: Condensation Sensor Helps control bathroom condensation to prevent mold and mildew.Sensor technology detects relative humidity and temperature to anticipate dew point,automatically turning the fan onto control humidity.Built-in Relative Humidity(RH)sensitivity adjustment enables fine tuning for moist conditions and for satisfying CalGreen requirements.When the condensation sensor is used in conjunction with multi-speed functionality,the fan will kick up to high speed when the condensation sensor detects moisture in the room.This module also activates a 20 minute delay off timer for the fan. FV-NLVKI: LED Night Light 4 A photocell automatically turns on the 1 watt LED night light when darkness is sensed in the room. High/Low brightness ip switch enables you to fine tune the photocell to work in conjunction with the darkness level of your bathroom.This module also activates an automatic 20 minute delay off timer for the fan. Fan Specifications WhisperGreen Select'"FV-05-11VK1 Static Pressure in inches w.g. 0.1 0.25 0.1 0.25 0.1 0.25 Air Volume(CFM) 110 113 80 82 50 53 Noise(sones) <0.3 0.8 <0.3 0.4 <0.3 <0.3 Power Consumption(watts) 9.8 16.1 5.4 10.2 3.2 6.5 Energy Efficiency(CFM/Watt) 11.5 7.2 15.3 8.4 15.1 8.1 Speed(RPM) 931 1205 814 1131 747 1072 Current(amps) 0.10 0.16 0.06 0.10 0.04 0.07 MAX.Current(amps) 0.27 Power Rating(V/Hz) 120/60 ENERGY STAR rated Yes 0.25=Installed Performance Fan Specifications WhisperGreen Select":FV-05-11VK1 +FV-VS15VK1 (Multi Speed Plug'N Play-Module) Static Pressure in inches w.g. 0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.25 Air Volume(CFM) 110 113 100 106 90 95 80 82 70 71 60 66 50 53 40 43 30 33 Noise(sones) <0.3 0.8 <0.3 0.7 <0.3 0.6 <0.3 0.4 <0.3 0.4 <0.3 0.3 <0.3 <0.3 <0.3 <0.3 <0.3 <0.3 Power Consumption(watts) 9.8 16.1 8.0 14.0 6.5 11.7 5.5 10.2 4.3 8.6 3.6 7.8 3.2 6.5 2.7 5.7 2.4 5.0 Energy Efficiency(CFM/Watt) 11.5 7.2 13.0 7.9 14.5 8.5 15.3 8.4 17.2 8.7 17.5 8.8 15.1 8.1 16.3 8.2 14.2 7.6 Speed(RPM) _ 931 1205 895 1179 852 1146 814 1131 772 _1112 750 1107 747 1072 731 1073 718 1062 Current(amps) 0.10 0.16 0.09 0.14 0.07 0.12 0.06 0.10 0.05 0.09 0.04 0.08 0.04 0.07 0.08 0.06 0.03 0.06 MAX.Current(amps) 0.27 Power Rating(V/Hz) 120/60 ENERGY STAR rated Yes 0.25=Installed Performance Panasonic Eco Solutions Company of North America F'' Most Efficient Eco Products Division 2016 Two Riverfront Plaza Newark,NJ 07102 EMIZEM www.e,e,9ysurgovIED us.panasonic.com/ventfans 9 'ri6r 44f' ff.m 0 d ,a l 1)- u s AzN is Panaso 8 ENE.SIAP VF16006ss0116 ASPEN BUILDING DEPARTMENT Water Circulation 00series Pumps & Circulators VR3452 ECM High-Efficiency Circulator Taco OOeTM series—VR3452 circulator is a self-adjusting, high-efficiency wet rotor circulator for chilled and hot water applications. All settings can be accomplished on the user-friendly interface. The ECM permanent magnet motor saves up to 85%of the electrical energy compared to conventional pumps. Operating Modes: • Auto mode (default) • Proportional pressure control • Constant pressure control • Constant speed • Night setback turndown 7.11111111111---__ 411, E. riesuVoA • gcm4- 52 ,,vR3k 111 Mom! I 3s / • aco° Comfort.A/Solutions ATaco Group Company©Taco Catalog#100-1 21 ERv(EI I F D Supersedes.09/04/15 10/09/18 ASPEN BUILDING DEPARTMENT Features&Applications ECM wet rotor circulation pump with integrated electronic regulation. • High-efficiency ECM motor uses up to 85%less electricity 10' ' AA& • LED displays watts,flow&RPM • Compact size for easy handling and installation • Plug&play simplicity 47 • Robust construction for long life o r series • Industry standard flange configuration and lay length ECM HIGH-EFFICIENCY CIRCULATOR it MODEL VR3452 • Low noise operation 1 • Cataphoresis coated volute I111 C I .. GPw attsM • Communication module (Standard on-FC1 A01 models): 10.707RP, — - Ethernet communication 3s i liik 0 v SET A) ► - Modbus RTU communication 35 - Analog Control input 0- 10 V ` w - 3 analog inputs/outputs IFSCO 1 relay output Cornfort_fsolutkoru A Taco Group Company - Main,Standby, Parallel Pump Operation ()Mies 00Peries 0reies MM. R;CIRCULATOR ir MODEL:: MODELVP,4,z 1 == l / - u -• 1.Ea i1 Iit O v T A v Ov SET A 31 O v SET A 3 —.‘ — ,.ACI , �3�� TCO 'WNW" TCO NOTE: Comfort/Sat., �. . ""°"°°°`m"" ""°"°°°`m"" — —,.,. Every mode has the ability to } Proportional Pressure Constant Pressure Fixed Speed or without Night SetbackTur� R,.I\1E L 10/09/18 ASPEN BUILDING DEPARTMENT VR3452 Performance Data VR3452 with control module 40 1 35 , 0Minimum Speed — Q Maximum Speed 30 ^"--• -w..s SHADED AREA IS 25 OPERATING RANGE r S 20 9 R S 15 5 la L11111111111111P0 i 0 10 20 30 40 50 60 J t Flow,Q(GPM)• AUTOMATIC MODE(factory setting) Ir A In automatic mode the pump automatically sets the operating pressure,depending on the hydraulic system.By doing so,the pump finds the optimal operating position.This mode is recommended in most systems. VR3452 without control module H• H . H4 Max. / Max. RPMset Max. Hset �� 1 O� Hset O Hset Imo\Q I O Min. ` Q Q Q PROPORTIONAL CONSTANT FIXED PRESSURE to PRESSURE SPEED The pump operates on a pre-programmed The pump operates at a constant The pump operates at its programmed inclining performance curve where the differential set pressure(Hset on the speed between 1100&4400 RPM as set by differential pressure increases with flow. user interface)from zero flow to maximum the operator(RPMset on the user interface). Hset on the user interface relates to the speed. Once maximum speed is reached Factory default is max speed(4400 RPM). differential pressure at maximum speed the differential pressure drops as flow with a corresponding differential pressure increases in a similar manor to a constant at zero flow of half of the Hset value.Hset speed pump. Hset range from 4.5'to 35' range from 4.5'to 35' in 0.5'increments. in 0.5' increments. Factory default is 17.5' Factory default is 17.5 41E) NIGHT SETBACK TURNDOWN When the pump operates in night mode,it automatically switches between the selected operating curve in the mode and night curve. The transition to the night mode depends on the media temperature in the system. When the night mode is prepared for operating,its icon illuminates and the pump operates in the selected operating curve of the mode. When the pump identifies the media temperature fall by 59-68F°(approximately during 2 hours),the icon starts to blink and the pump switches to the night curve. When the media temperature rises again,the icon stops blinking and the pump passes over to the operating curve in the selected operating mode. The night mode operates only in combination with the above indicated modes. It is not an independent operating modRE C lyE L 10/09/18 ASPEN BUILDING DEPARTMENT Submittal Data Information Submittal Data# 101 173 Effective:04/27/16 OOeTM series—VR3452 Supersedes:08/04/15 Specifications Applications • Maximum Shutoff Head:34 feet The VR3452 circulator is used for circulation of water or a mixture of water/ glycol in hot water heating systems,air conditioning systems and closed loop • Maximum Flow:52 gpm circulation systems.Operating modes include self-adjusting auto,proportional • Maximum Operating Pressure: 145 psi pressure,constant pressure,constant speed and night setback. (10 bar) *, B C • Maximum Water Temp:230°F(110°C) 2u - • Minimum Water Temp:14°F(-10°C) -- • AmbientTemp Range: �, 'i. 32°F(0°C)to 104°F(40°C) >" . F ,,,,, 1 • Minimum Inlet Pressure: tali i�a� �- 112°F(50°C)0.73 psi/0.05 bar „—� 1 . - r 176°F(80°C)5.8 psi/0.4 bar E *Controller Module standard on-FC1 A01 models.Adds 1-5/16"to dimensions B and C. 230°F(110°C) 15.95 psi/1.1 bar • Electrical specifications: Pump Dimensions&Weights 1 phase,110-120V,47-63Hz(VR3452-HY1) A B C E F Weight 1 phase,200-240V,47-63Hz(VR3452-HB1) Model in. mm in. mm in. mm in. mm in. mm lbs. Kg • Operating Power: 1/4HP, 10-180W VR3452-FC1A00 6-3/8 162 9-1/2 241 7-7/16 189 4-5/8 117 7-7/16 179 7.8 3.5 • Rated Current: VR3452-FC1A01 6-3/8 162 10-3/4 273 8-3/4 222 4-5/8 117 7-7/16 179 7.8 3.5 (1 phase, 115V) 0.1 A to 2.5A (1 phase,230V) 0.1 A to 1.5A • Continuous Duty Additional Data Model Volts Class Flange Size HP Hz Ph Max. Max. RPM • Built in start-up circuit Amps Watts • Equipped with a cast iron casing VR3452-HY1 115 Class H 3/4 to 1-1/2 1/100 to 1/4 50/60 1 2.5 180 1100-4400 and should be used for closed loop systems only VR3452-HB1 230 Class F 3/4 to 1-1/2 1/100 to 1/4 50/60 1 1.5 180 1100-4400 • Taco circulator pumps are Motor ECM,Permanent Magnet,Impedance Protected for indoor use only Type • Acceptable for useo with water or Mounting Positions Flange Orientation maximum of 50%water/glycol solution 1 _,._ .3 • Degree of protection:IP 44,Class 2 - 1,1 4 � 1__'--] o 151: Materials of Construction: f (7-:::-,.._1 1 I ''I) II L1 .. Casing: Cast Iron lii �I Impeller: Non-Metallic , IF Shaft: Stainless Steel Bearings: Graphite ���� Companion flanges are.75"to 1.5" o T iPr (same as used on Taco 00°series). Rotor Can: Stainless Steel :BF' E J �r See catalog 100-7.3 and 100-56 �__ ////h �I4, Certifications&Listings: lift Conforms to UL Standard 778 Certified to CSA Standard 22.2 No 108 Eta U9 9 4004896 WaC* 0® 0048 FOR INDOOR USE ONLY Comfort_,/Solutions RECEIVED ATaco Group Company Taco Inc.,1160 Cranston Street,Cranston,RI 02920/(401)942-8000/Fax(401)942-2360 10/0 9/18 Taco(Canada)Ltd.,8450 Lawson Road,Unit#3,Milton,Ontario L9T 0J8/(905)564-9422/Fax(905)564-9436 www.TacoComfort.com ASPEN BUILDING DEPARTMENT Wd/CO® In st ru ct i o n Sheet 302-368 Comfort. Solutions A Taco Family Company 00eTM Series VR3452 SUPERSEDES: February 29, 2016 EFFECTIVE: February 17, 2017 1. GENERAL INFORMATION: A CAUTION:Do not operate pump without the electri- The circulating pumps are used for the transfer of liquid media cal cover securely attached. within a closed-looped hot-water heating or air-conditioning ATTENTION: Ne pas actionner la pompe si le cou- hydronic system. They are designed as single or parallel vercle electrique n'est pas correctement fixe. main/standby operation variable-speed pumps, where the speed is regulated by an on-board electronic device.They are to be used with a water or glycol/water mixture. A CAUTION: Pump motor,electronics enclosure and 2. SAFETY: condensate drain openings should not be thermally 1 insulated as it could interfere with cooling and These instructions should be studied carefully before installing or condensate drainage. operating the pump. They are meant to help you with installation, ATTENTION: Le moteur de pompe, ('enceinte elec- use and maintenance and to increase your safety. Installation tronique et les ouvertures de drainage de condensat should be performed with regards to local or national standards. doivent etre thermiquement isoles car ii peut y avoir Only qualified personnel should maintain and service these prod- interference avec ('evacuation de condensat et de ucts. Failure to comply with safety precautions could cause per- liquide de refroidissement. sonal injury or machinery damage. 3. PUMP DESCRIPTION: Ai WARNING: Do not use in swimming pool or spa areas. Pump has not been investigated for these The high efficiency, electronically commutated Vr3452 pumps con- applications. sist of two main parts, the centrifugal pump and the electronic reg- AVERTISSEMENT: Ne pas utiliser dans une piscine ulator. The hydraulic part is hermetically sealed from the motor ou un spa. La pompe n'a pas ete etudiee pour ces assembly and has no mechanical seals. Vr3452 pumps are pow- applications. ered by an ECM permanent magnet motor which does not consume energy to magnetize the rotor, providing superior energy efficiency. The ECM motor is run by an on-board frequency converter with an A WARNING: To avoid electrical shock, disconnect the power supply to the circulator and the main integrated PFC (Power Factor Correction) filter. The converter estimates current flow and head from the motor load, information electrical unit. Follow all local electrical and essential for differential pressure control. plumbing codes. 4. USE: AVERTISSEMENT:Pour eviter tout choc electrique, debranchez('alimentation electrique vers le circu- The Taco 00e VR3452 pumps are intended for circulation of solid- lateur et ('unite electrique principale. Respectez free fluid in pressurized, hot and chilled hydronic systems. The tous les codes de plomberie et electriques locaux. self-sensing ECM pump constantly calculates pressure and flow, and adapts its speed to the appropriate flow. WARNING: Hot surfaces can cause burns. The 5. PUMPED FLUIDS: Amotor can also reach temperatures that could Use water and water/glycol mixtures only. Water/glycol mixtures cause injury. must be HVAC-system compatible and should have no more than AVERTISSEMENT: Les surfaces chaudes peuvent 50%concentration of glycol. The fluid shall not consist of aggres- provoquer des brulures.Le moteur peut egalement sive or explosive additives and mixtures of mineral oils and solid atteindre des temperatures qui peuvent entrainer or fibrous particles. The pump should not be used for pumping des blessures. flammable, explosive fluids, and in an explosive environment. 6. INSTALLATION: A CAUTION: The addition of petroleum based fluids The pump must be mounted with motor shaft in a horizontal posi- or certain chemical additives to systems using tion (see Figure 1). The permitted and prohibited positions are TACO equipment voids the warranty. shown in Figure 2. The arrow on the hydraulic part indicates the ATTENTION: L'ajout de liquides a base de petrole proper direction of the fluid flow. Pumping in a downward direction ou de certains additifs chimiques a des systemes may cause system issues but will not shorten the life of the pump. utilisant un equipement TACO annule la garantie. Installing the pump with the electrical connector vertically above the motor is not recommended (see Figure 3). Where the installa- tionCAUTION: Use supply wires suitable for 90°C. causes the electrical connector vertically above the motor,the A ATTENTION: Employer des fils d'alimentation motor can be rotated so that theelectrical connector is in a hori- zontal position as described in Sectionction6.1. adeqauts pour 90°C. A CAUTION: Misconnection or overload of electrical or signal connections could cause pump to shut- downcause permanent damage.ARECEIVED ATTENTION: ION:Toute erreur de raccordement ou sur- charge des connexions electriques ou de signali- sation peut entrainer un arret de la pompe ou des dommages permanents. 10/0 9/18 ASPEN BUILDING DEPARTMENT PERMITTED AMBIENT AND MEDIA TEMPERATURE: Ambient Fluid Temperature Ambient Fluid Temperature Temperature[°F] Min. [°F] Max. [°F] Temperature[°C] Min. [°C] Max.[°C] Upto75 36 230 Upto25 2 110 85 36 212 30 2 100 95 36 203 35 2 90 105 36 175 40 2 80 Note:Operation outside recommended conditions may shorten pump lifetime and void the warranty. FIGURE 1 FIGURE 2 i .... . . • . 1,,.__,1 iii, , ____.. _ 1.(3.-, -• - T 1 . ..i.:_ire.),— ...- : :.,. E ;ii: _ . _...... �=.. .. •j. _. FIGURE 3 FIGURE 4 FIGURE 5 ac iv ,ram . .icr . 1.111,420.,_. .-. _ t -- 1) .4t1W .-1. - lj , 4.... „:,.,._. ') 4164- -;----, 6.1 Motor Rotation Procedure 1. If possible, change the orientation of the motor before Before starting the pump, the system (and pump) must be filled installing pump in piping. With motor in a vertical position, with fluid, and air completely bled out of the system. For proper remove the 4 bolts (Figure 4-5/32" or 4mm Allen hex wrench operation, pressure must be maintained on the suction side of the required) and turn the motor (Figures 5 or 6) to conform with pump. The pump does not have screws for bleeding the air, as it the desired orientation of pump (see Figure 2). If motor won't is automatically bled as a function of the design of the pump. rotate, insert a screwdriver between pump casing and motor Temporary air in the pump will generate noise that disappears stator housing and raise slightly. Try turning motor. Insert after a short time. screwdriver on opposite side, raise slightly, and try turning the motor. Motor should now turn-line up bolt holes when desired WARNING! orientation is achieved. • The maximum system pressure is 145 psi (1 MPa or 10 bar). 2. Caution: If system is filled and pressurized, shut off valve • The pump must always be filled with system fluid as it is water before and after the Vr3452.Allow to cool if system fluid is hot. lubricated and water cooled. 3. If the pump is already installed in the piping, remove the 4 • The motor stator openings and stator housing (Figure 7) bolts (5/32" or 4mm hex wrench required) and try rotating the should not be insulated,since the thermal insulation might pre- motor without backing it out from the pump casing. Try lifting vent motor cooling and the evacuation of condensate from the the motor approximately .020" using a screwdriver between pump's motor housing in high ambient humidity applications the motor and pump housing and try turning the motor. where the system fluid temperature is below the motor temper- 4. If motor will not move, remove motor completely. ature. 5. Remove impeller, rotor, and rotor can from the motor. Note: FIGURE 7 Rotor and impeller assembly will come out first. Remove Connector Use Taco Part No.099-1318 contents to moderately rotor can from motor and put aside. to Assembly lubricate assembled 0—rings for ease of assembly Into circulator housing 6. Install impeller and rotor assemblyinto pump. °o" II, ' " - 7. While holding rotor,install 0-ring in casing,and then slide rotor 4 e can over rotor and slide all the way in. Note: The rotor and e f ) ��[ ‘ F rotor can is a sealed unit. 1limati r 8. Pick up the motor with the terminals properly orientated and ". III, carefully start to slide the motor over the rotor can. The resis- �:., tance of the sliding will keep the rotor and rotor can assembly nsalolatl i1G!!able°° in place and the screwdriver can be moved. Note: Do not .=and 4fi" CEIVED allow the motor to droop or the 0-ring might get out of 1 2 3 4 position. '0 P011 male to 1/2 14 NPSM female thread adapter for use with I'q id—t'ght flex bin condu t nstallat'ons 10/0 9/18 T ghlening torque for thread adapter or cable gland's 11.1+/-22 inIb 2 ASPEN BUILDING DEPARTMENT 7. ELECTRICAL CONNECTION: • 5 seconds together with [J] and [+] keys to restore pump to Connection of the pump must comply with local electrical codes factory default settings. and be carried out by qualified personnel.Connection to the power [J] Key supply is carried out with the enclosed connector, the mounting of which is shown in the picture accompanying the connector. When Short press: connecting the pump, the following must be considered: • To confirm currently selected values of both mode and para- • Liquid tight power connection required to maintain IP44 enclo- meter. sure rating. Use supplied thread adapter option for flexible or Long press: armored cable installations. • 3 seconds to enable mode selection. • Maximum power input wire size: 16 & 12 AWG solid or multi- • seconds together with long press on [+] and [-] keys to strand copper for portable cord &flexible conduit installations; restore pump to factory default settings. respectively. • Local or national electrical code requirements supersede [+] Key Taco's specification. Short press: • Install an electrical disconnect to comply with national electri- cal code. • Scrolling through parameters upwards, not changing parame- • Connection of the power supply electrical cable must be done ter values. in a manner that ensures it does not contact the motor housing • Scrolling through modes upwards when mode selection is and volute of the device, due to potential high temperatures of selected. both. • Changing parameters downwards when setting parameter val- The pump has built-in over current fuse protection, temperature ues. protection, and basic overvoltage protection. It does not require Long press: additional overload protection devices unless required by local • 3 seconds together with [-] key to enable night setback electrical codes. Power supply cabling should be capable of carry- mode. ing rated power and be properly fused. Grounding connection is • 5 seconds together with [J] and [-] keys to restore pump to essential for safety and should be connected first. Grounding is factory default settings. only meant for pump safety. System piping should be grounded separately. 8.4 Operation and Setting of Pump Modes 8. SETUP AND OPERATION: To switch between modes(except night mode) press and hold the [✓] key for 3 seconds then select the desired mode with the [+] 8.1 Control Panel or [-] key. Once desired mode is selected, press the Li] key to confirm. 1. Bar Display of Values Once the desired mode is selected, the factory default parameter 2. Numerical Display of Values is displayed numerical display(except for Auto Mode). If required, theparameter value can be changed with the[+] orkey,then 3. Unit Display of the Currently 9 [-] Selected Parameter (Watts, confirm the parameter setting by pressing the [J] key. o 00��0 4Head Setting, Flow, or Speed) To activate or deactivate the night setback feature, simultaneously �• 4. Display of the Currently press and hold the [+] and [-] keys for 3 seconds. o- + Selected Mode 5. [+] Button To scroll through the parameter values within a mode, use the[+] 6. [J] Button or [-] keys. The desired parameter is selected (see individual 7. [-] Button mode) with the [J] key. The parameter value is then selected s using the [+] or [-] keys. The selected value is confirmed using 7 5,8.2 Switching the Pump Motor On and Off the [✓] key. When the pump is powered for the first time, it operates with the 8.5 Mode Descriptions factory default settings in automatic mode. The pump can operate in 4 different modes to optimize the perfor- With subsequent motor start-ups and/or power-ups, due to the mance of the pump and maximize the system efficiency, based on non-volatile memory the pump will operate with the last settings the specific system type. that were set prior to its shut-down. Battery back-up is not The pump modes are: required. • Automatic Mode (factory default) To switch the pump off, press and hold the [-] key for 5 seconds, • Proportional Pressure (increased differential head as flow until OFF is shown on the display. When the pump is switched off, increases) the numerical display shows OFF. • Constant Pressure (constant pressure as flow increased) To turn the pump on, press the [-] key briefly. • Constant Speed (user selectable to match system requirements) Each mode can be combined together with night mode. 8.3 Pump Functions [-] Key Automatic Mode (factory default) Short press: In automatic mode the pump automatically sets the operating pressure, depending on the hydronic system. By doing so, the • Scrolling through parameters downwards, not changing para- pump finds the optimal operating setting. This mode is recom- meter values. • Scrolling through modes downwards when mode selection is mended in most systems. The parameters cannot be set; they selected. can only be scrolled through. • Changing parameters downwards when setting parameter val- Proportional Pressure a• ues. The pump maintains the pressure with relatio . I. f', ED Long press: to the current flow. The maximum differenti.• - �' A • 3 seconds together with [+] key to select night setback mode. head is the set pressure (Hset on the diagram T • 5 seconds to switch off the pump. at maximum speed; at 0 flow the differential „ 8 i •pressure is 50% of the Hset setting. As the P...t nap e 3 ASPEN BUILDING DEPARTMENT system flow changes the pump's differential ". 10.SPECIFICATIONS AND PUMP CHARACTERISTICS: pressure changes linearly along the line between Hset and 0 flow. tQ Ma. 10.1 Application: Hier • Maximum Operating Pressure: 145 PSI (10 bar) Constant Pressure 40 \ • Water Temperature Range: 36°—230°F (-10°— 110°C) The pump maintains the current set pressure • Ambient Operation Temperature Range: 32°—104°F (Hset on the drawing), from 0 flow to maxi- Constant pressure Q (0°—40°C).Ambient temperature should be 104°F (40°C) mum flow, where the pressure begins to " or lower when fluid temperature exceeds 194°F (90°C). drop. • Minimum static inlet pressure at pump suction to avoid RPM set Ma.. damage to the bearing assembly: Constant Speed M° f Q • Relative Humidity: Max. 95% The pump operates with the currently set Q`` • System Pressure: Up to 145 PSI (10 bar) speed (RPMset on the drawing). In the Copsranr • Designed for closed loop heating and cooling systems unregulated mode, we can onlyset the rev°I°t°°s 9 pumping water or a water/glycol mixture. speed at which the pump will operate and scroll through the other • For indoor use only- employer uniquement a l'interieur. parameters. FLUID PSI/bar Night Mode 0 TEMPERATURES When the pump operates in night mode, it automatically switches 112°F(50°C) 0.73/0.05 between the selected operating mode and night curve.The transi- 176°F(80°C) 5.80/0.40 tion to the night mode depends on the fluid temperature in the sys- tem. 230°F(110°C) 15.95/1.10 When the night mode is enabled, its icon illuminates and the pump 10.2 Electrical Data: operates in the selected operating curve of the mode. When the pump identifies the media temperature falling by 60 to 70 F° (15 ' Pump Ratings:l phase, 110 120V,47 63Hz (VR3452-HY1) 20 C°) over a 2 hour time period, the icon starts to blink and the 1 phase, 200 240V, 47 63Hz (VR345-HB1) pump switches to the night curve.When the fluid temperature rises • Power Consumption (HP): '/HP again, the icon stops blinking and the pump switches to the oper- • Power Consumption (W): 10- 180 W ating curve in the selected operating mode.The night mode oper- • Rated Current(1 phase, 115V): 0.1 -2.5 A ates only in combination with the above indicated modes. It is not • Rated Current(1 phase, 230V): 0.1 - 1.5 A an independent operating mode. 10.3 Standards, Protection and Connection: 8.6 Setting the Pump to Factory Settings • Insulation: Class H (VR3452-HY1) To restore factory defaults, press and hold all three buttons for 5 Class F (VR3452-HB1) seconds.The pump will be set to the automatic mode of operation. • Enclosure: Class 2, IP44 Any previously set values for pressure and RPM will be deleted. • Integrated Motor Protection (electronically protected) • 9. OVERVIEW OF POSSIBLE ERRORS AND SOLUTIONS UL 778, 1004-1, 508C • CAN/CSA C22.2#108, #100, #107.1 If a pump failure or overload occurs, the error code will appear on • EMC (89/366 EEC): EN 61000 the display screen as indicated in the table below. X is the error • LVD (73/23/EC): EN 60335-1, EN 60335 2 51 group and Y is the service code (intended for service personnel. • Machine Safety(98/37/EC): EN ISO 12100 • Flange Connections: Residential 2 bolt flange from 3/4" to Error Error 11/2" NPT - See Freedom Flange catalog (100-7.3), Shut-off Group(X) Description Possible Cause&Solution Freedom Flange catalog (100-31), and Shut-off Freedom Swivel Flange catalog (100-56)on www.taco-hvac.com. The Low Load Pump running dry purge/fill the system. VR3452 uses the same flanges as"00"series (exc 0012). Detected 10.4 Materials of Construction: Motor Excessive amperage and/or sticking rotor • Casing: Cast Iron, Cataphoresis Coated 2 Overload assembly.Confirm voltage/amperage and check rotor/impeller spins freely. • Impeller: PES Motor exceeded temperature limitation ' Shaft: Stainless Steel and is stopped to allow the motor to cool • Bearing: Carbon 3 Motor Too Hot down. Once cooled the pump will auto- matically restart and the error code recorded. Electronics An electronic error was detected. The 4 Error pump can still operate but requires ser- vicing. 5 Motor/Stator Possible motor wiring failure. Pump motor Failure requires servicing. See page 5 for error codes. RECEIVED 10/09/18 4 ASPEN BUILDING DEPARTMENT ERROR CODES The following codes will show up on display panel and on the appropriate Modbus registers to help you diagnose the cause of improper operation. Error code Description Probable cause Eix Load errors El(drY) Low motor load Low load detected.Pump is running dry. E11 High motor load Motor might be faulty or viscous medium is present. E2x Protection active E22(hot) Converter temperature limit Circuit is too hot and power was reduced to less than 2/3 of rated power. E23 Converter temperature protection Circuit is too hot to run,pump stopped. E24 Converter overcurrent Hardware overcurrent protection triggered. E25 Overvoltage Line voltage is too high. E26 Undervoltage Line voltage is too low for proper operation. E3x Pump errors E31 Software motor protection active Average motor current was too high,pump load is much higher than expected. E4x Device specific error codes E40 General frequency converter error Electrical circuitry did not pass self-test. E42(LEd) LED faulty One of the display segment diodes is faulty(open/short). E43(con) Communications failed Display board does not detect proper connection to main board,but power supply is present. E44 DC link current offset Voltage on DC link shunt(R34)not in expected range. E45 Motor temperature outside limits During MFG.TEST,this is 10 ki2,1%resistor for 10°C..30°C During operation,expected values are-55°C..150°C. E46 Circuit temperature outside limits During MFG.TEST,this is 0°C..50°C. During operation,expected values are-55°C..150°C. E47 Voltage reference outside limits. Comparison between internal references does not match. E48 15V outside limits 15 V supply not 15 V. E49 Test load does not match No test load detected or current measurement does not work properly(MFG.TEST). E5x Motor error codes E51 Motor parameters out of range Motor does not behave as expected. LIMITED WARRANTY STATEMENT Taco, Inc. will repair or replace without charge chemical additives to the systems, or other FORTH IN THE FIRST PARAGRAPH ABOVE. (at the company's option) any product or part abuse,will not be covered by this warranty. which is proven defective under normal use with- THE ABOVE WARRANTIES ARE IN LIEU OF If in doubt as to whether a particular substance in one (1) year from the date of start-up or one ALL OTHER WARRANTIES, EXPRESS OR is suitable for use with a Taco product or part,or (1) year and six (6) months from date of ship- for any application restrictions, consult the STATUTORY, OR ANY OTHER WARRANTY ment(whichever occurs first). applicable Taco instruction sheets or contact OBLIGATION ON THE PART OF TACO. In order to obtain service under this warranty, it Taco at[401-942-8000]. TACO WILL NOT BE LIABLE FOR ANY SPE- is the responsibility of the purchaser to promptly Taco reserves the right to provide replacement CIAL, INCIDENTAL, INDIRECT OR CONSE- notify the local Taco stocking distributor or Taco products and parts which are substantially similar in writing and promptly deliver the subject prod- in design and functionally equivalent to the defec QUENTIAL DAMAGES RESULTING FROM THE uct or part,delivery prepaid,to the stocking dis- five product or part. Taco reserves the right to USE OF ITS PRODUCTS OR ANY INCIDENTAL tributor. For assistance on warranty returns,the make changes in details of design, construction, COSTS OF REMOVING OR REPLACING purchaser may either contact the local Taco or arrangement of materials of its products with- DEFECTIVE PRODUCTS. stocking distributor or Taco. If the subject prod- out notification. uct or part contains no defect as covered in this This warranty gives the purchaser specific rights, warranty, the purchaser will be billed for parts TACO OFFERS THIS WARRANTY IN LIEU OF and the purchaser may have other rights which and labor charges in effect at time of factory ALL OTHER EXPRESS WARRANTIES. ANY vary from state to state. Some states do not examination and repair. WARRANTY IMPLIED BY LAW INCLUDING allow limitations on how long an implied warranty Any Taco product or part not installed or operat- WARRANTIES OF MERCHANTABILITY OR lasts or on the exclusion,sotheseo incidentalc or exclu- ed in conformity with Taco instructions or which sions quential damages, limitations or exclu- ed been subject to misuse, misapplication,the FITNESS IS IN EFFECT ONLY FOR THE DURA- sio may not apply to you. addition of petroleum based fluids or certain TION OF THE EXPRESS WARRANTY SET CO Comfortl5O/Ut/OnST"ATaco Family Company JOD Taco,Inc.,1160 Cranston Street,Cranston,RI 02920 I Tel:(401)942-8000 I FAX:(401)942-2360 IVE Taco(Canada),Ltd.,8450 Lawson Road,Suite#3,Milton,Ontario L9T 0J8 I Tel:(905)564-9422 I FAX:(905)564-9436 Visit our web site:www.TacoComfort.com I Printed in USA I 02017 Taco,Inc. 10 0 9 18 5 ASPEN BUILDING DEPARTMENT Taco' Submittal Data Information 301-2694 ComforteSoIut/ons' 00em Series VR3452 A Taco Group Company EFFECTIVE: February 29, 2016 SUPERSEDES: July 20, 2015 JOB ENGINEER CONTRACTOR REP ITEM NO. MODEL NO. G.P.M. T.D.H. MAX HP ELEC.CHAR. H MAX SETTING %PROP SETTING WEIGHT PUMP/MOTOR "B" r "D" 1 COMMUNICATION MODULE I ASSEMBLY VIEW ^� BLACK Mk. It o m A —1.11 11 1 O x x i '- F �lu ¢ ' 6 ; a = t eo+,o =m1n I c �Ir' � J (eQz_itao•�., II, till _ i '':.•.:�' -- -1■I mil ,= z h J ,iggi1111 "E" 2X CABLE GLAND Use P/N 099-1318 to moderately ELECTRICAL CONNECTOR lubricate assembled 0—rings for M12x1.5 ease of assembly = CABLE GLAND ELECTRICAL CONNECTER CONDUIT ADAPTER SUPPLIED WITH CIRCULATOR TO SUPPORT LIQUID TIGHT ARMORED CABLE INSTALLATION. CONNECTION SIZE: PG11 MALE TO 1/2-14 NPSM FEMALE THREAD ADAPTER DIMENSIONS: MODEL FLANGE POWER DIMENSIONS — IN.(mm) WEIGHT NUMBER SIZE (HP) A B C D E F LBS. (KG) VR3452-FC1A00 3/4 to 11/2' 1/100 to 1/4 6-3/8(162) 9-3/4(247) 7-1/2(190.5) 4 (102) 4-5/8 (117) 7(177.8) 8.0(3.6) VR3452-FC1A01 3/4 to 11/2' 1/100 to 1/4 6-3/8(162) 11 (279) 8-3/4(222.25) 4 (102) 4-5/8 (117) 7(177.8) 8.3(3.8) (with comm module) PUMP SPECIFICATIONS: MATERIALS OF CONSTRUCTION: • Maximum Operating Pressure: 145 PSI (10 bar) • Casing:Cast Iron cataphoresis coated • Water Temperature Range: 14°—230°F(-10°—110°C) • Impeller: Engineered Polymer • Ambient Operation Temperature Range:32°—104°F • Shaft:Stainless Steel (0°—40°C).Ambient temperature should be 104°F(40°C) • Bearing: Metal Impregnated Carbon or lower when fluid temperature exceeds 194°F(90°C). • Minimum static inlet pressure at pump suction port ELECTRICAL SPECIFICATIONS: (PSI/bar)to avoid cavitation at fluid temperatures: • Pump Ratings: 1 phase, 110-120V,47-63Hz(VR3452-HY1) FLUID (PSI/Bar) 1 phase,200-240V,47-63Hz(VR3452-HB1) TEMPERATURES • Power Consumption: 1/4HP, 10-180W 112°F(50°C) 0.73/0.05 • Rated Current: (1 phase, 115V)0.1 A to 2.5A 176°F(80°C) 5.8/0.4 (1 phase,230V) 0.1 A to 1.65A 230°F(110°C) 15.95/1.1 • Continuous Duty • Built-in Startup circuit • Designed for closed loop heating and cooling systems RE �� /� pumping water or a water/glycol mixture. C V • For indoor use only-employer uniquement a I'interieur. • Flanged in-line connections. Companion flanges not included. Uses 3/4"to 1-1/2" Freedom Flanges-see cat#100-7.3, 10/0 9/18 005-0011 flanges. ASPEN BUILDING DEPARTMENT STANDARDS and PROTECTION: OPERATING MODES: • Insulation: Class F, 230V; Class H, 115V • Factory default:Automatic • Enclosure: Class 2, IP44 • Delta P-V • Integrated Motor Protection (electronically protected) • Proportional Pressure Control • UL 778 • RPM Regulation • CAN/CSA C22.2#108 • EMC (89/366 EEC): EN 61000 • LVD (73/23/EC): EN 60335-1, EN 60335-2-51 • Machine Safety (98/37/EC): EN ISO 12100 ETA us „srEo Intertek OOe 3452 PERFORMANCE CURVE 40 35 — 30 25 I 20 = 15 10 5 0 0 10 20 30 40 50 60 Flow,Q(GPM) Comments: Comfort,iSOlUt/0nS ATaco Group Company IVED Taco,Inc.,1160 Cranston Street,Cranston,RI 02920 I Tel:(401)942-8000 I FAX:(401)942-2360 Taco(Canada),Ltd.,8450 Lawson Road,Suite#3,Milton,Ontario L9T 0J8 I Tel:(905)564-9422 I FAX:(905)564-9436AVEIVED 0 9/18 Visit our web site:www.TacoComfort.com I Printed in USA I ©2015Taco,Inc. ASPEN BUILDING DEPARTMENT Water Circulation or series Pumps & Circulators OOe® Series VR ECM High-Efficiency Circulators The 00e'series—These are browser accessable,high-efficiency,wet rotor,variable speed, sensorless commercial pumps for chilled and hot water applications. Available in four sizes (VR 15-3,20-3,25-3 and 30-3),the sensorless 00e VR line provides differential head pressures up to 42 ft.and flows up to 360 GPM. The ECM motor provides up to 85%electrical energy savings compared with conventional pumps and its multiple operating modes fit most applications. • Simple user interface to enable setting changes on the face of the pump,eliminating the need for laptop setup �- • Real-time performance readouts . for flow, power consumption, speed and head values OCCA ,f • Self Sensing Dynamic Auto (factory default),Proportional &Constant Pressure plus Manual -* Variable Speed modes provide for extremely extensive ithr application flexibility 11-!` • On board 0 10Vdc two way control adjusts speed or head to meet system demands from external control inputs 1 .1 • ModBus control and performance feedback for advanced Building Management/Building ►,� Automation Systems .11F-a4 • RJ45in ut/outputfor t p 4004896 ease of networking Web connections are a snap. • Relay outputs for remote monitoring of pump status and digital inputs for external enable/disabling • Simple Main/Standby and Parallel Pump operation (parallel pumps run together as needed)via standard ethernet cabling Wdico Comfort/Soiutions® A Taco Family Company ©Taco Catalog#300-23 REE1VE Supersedes:06/23/17 10/09/18 ASPEN BUILDING DEPARTMENT A convergence of efficiency, simplicity & technology. Efficiency as the basis of design precisely drive the rotor as fast as Flexibility to fit the job The ECM based design combines a the rotating flux,significantly reduc- The hydraulic characteristics of the brushless Electronically Commutat- ing motor efficiency losses while pump can be set at will. Pump ed Motor with a strong permanent greatly increasing starting torque. regulation can be done by pressure, magnet rotor. An ECM motor does speed,electrical power or a combi- not waste any energy in order to Full variable speed control nation of these,so it can be adapted magnetize the rotor and the posi- matches system requirements to different hydraulic system tion of the magnetic poles of the The electronics continually adapt requirements without the need rotor and stator generate continu- the speed to match the require for external regulators or sensors. ous thrust in the rotating direction ments of the system. Because the of the rotor. The integral electronics electrical motor is being driven by Ready-to-go out of the box,this an on-board frequency converter pump will automatically adjust its cnoosscmutot,00 the electric current is rectified and speed based on internally sensed converted into the appropriate variable differential pressure control, phase angle to maximize energy providing optimal energy savings 1 efficiency,even when operating at across the industry's largest oper hydraulic partial load conditions. ating range. Additional modes of The superior motor efficiency,opti- control can be selected to provide mized speed control,and intelligent constant pressure control, propor- sensorless variable speed pump tional pressure control,constant The position of the magnetic poles of the rotor control delivers dramatic cost sav- maintains ultimate motor EFF over the speed curve duty(uncontrolled pump), and load range of the unit. ings over the life of the system. multiple speed,RPM regulation or Up to 85%Electrical Savings power limitation control. Connecting with Ethernent These pumps can be operated as crossover cable :' ,..._ single, parallel or series variable speed pumps. The onboard elec- n tronics allows the user to choose to run two pumps in parallel,standby lilt or alternating modes. The built-in normally open,or normally closed relay contacts can be used to • activate or deactivate a primary or TheCloud ? ` secondary pump contact, provide .11111 �` external operation or overload — MI Connecting feedback or switch another piece of with LAN Ill • • equipment. In addition,this pump • comes standard with 2 external digital inputs and 1 external digital alb- output to be available for additional mechanical room control and pump monitoring. RECEIVED 10/09/18 ASPEN BUILDING DEPARTMENT Taco; the new generation of wet rotor pumps. Heating,air conditioning or chilled water systems These pumps are built to exacting .44411p specifications meeting the widest range of closed loop hydronic imii6_ heating and cooling applications. They are suitable for use with fluids at temperatures from 14°-230°F _ _ = . (-10°- 110°C) feature 175psi working --- '"' • pressure and have a stainless steel • • impeller and shaft.Continuous En `r'gtf MI duty rated with a built-in soft p Q •start-up circuit the VR15-3&VR20-3 can accept 110-240 volt and the D E VR25-3 and VR30-3 operate on NMI MD 230-240 volt supply power. Lower installation,commissioning and total cost of ownership Orieer.les OM=, OCRes A simple ethernet connection on the .:: I 4 pump gives instant remote control, a`;,-, �°�.EF^1 % r; ^...., monitoring and adjustment without -,..-ara T( -Waco requiring highly skilled network Proportional Pressure Constant Pressure Fixed Speed IT or commissioning personnel. Web-based simplicity The environment is Adjustments for Proportional Simply launch any common browser always a consideration Pressure,Constant Pressure and (Internet Explorer®or Firefox®)type in Not only do these pumps use 85% Fixed Speed can now be made "OOe"or the pump's IP address in the less energy(Meeting EUlegislation directly on the pump. browser's address line and you have with "A"class energy rating)than instant,automatic and full control a standard commercial pump but The in-line design and standard over the pump(s). we also made the choice to use ANSI class 125 flanges make for a components, processes and technician friendly installation. The The HTTP or FTP protocol ensures manufacturing capabilities which pump and motor form an integral a user-friendly,commonly used keep the environment in mind. unit without a mechanical seal. environment. The bearings are lubricated by the Performance Range pumped fluid,ensuring years of 0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 50 quiet,maintenance free operation. as 0 VR15-3 14 To protect your investment in the °`AIEcHEJc!I ©VR25-3 12pvR3o-3 ,0 e status and over temperature protec- = 20 6 tion. Given all the advantages stated 15 -4414111111 above,the total cost of ownership of ,o a the pump is by far the lowest for its 5 2 performance range. ° _ E(EIVEL` a zs 50 15 100 125 150 175 200 zzs 250 275 300 325 350 3]' FLOW(GPM) �� Mr 10/09/18 ASPEN BUILDING DEPARTMENT Submittal Data Information Submittal Data#301-3000 Effective:08/08/17 Supersedes:05/09/17 00e° series —VR15-3, 20-3, 25-3 & 30-3 Pump Specifications Electrical Specifications Max.Operating Pressure: 1 phase,110-240V,47-63Hz(VR15&VR20) 175 PSI(12 bar) Pump Ratings 1 phase,230-240V,47-63Hz(VR25&VR30) Water Temperature Range: 36°-230°F(2.2°-110°C) VR15-3=0.027-0.68 HP Ambient Operation Temperature Range: VR20-3=0.035-1.088 HP 32°-104°F(0°-40°C) Power Consumption(HP) VR25-3=0.054-1.496 HP Designed for closed loop heating and VR30-3=0.054-2.175 HP cooling systems pumping water or a water/glycol mixture VR15-3=20-500 W Power Consumption(W) VR20-3=26-800 W Materials of Construction VR25-3=46-1100 W Casing Cast Iron VR30-3=40-1550 W Impeller Stainless Steel VR15-3=5.6A-2.8A Shaft Stainless Steel Bearing Metal Impregnated Carbon Rated Current VR20-3=7.2A-3.6A (1 phase,230V) VR25-3=5.3A Standards&Protection VR30 3=7.2A Insulation:Class H VR15-3&VR20-3=6 A Current Limit(Max.) Enclosure:Class 2,IP44 VR25-3&VR30-3=8 A Integrated Motor Protection Max.Current upto 100 mA,OutputVolta e (electronically protected) 24V Supply Output of 24V 20%, ut Output Ripple uner 1 V g Continuous Duty p pp UL 778,1004-1,508C CAN/CSA C22.2#108,#100,#107.1 Relay Output: 8A,Max.Voltage 250 VAC,48 VDC EMC(89/366 EEC):EN 61000 Max.Load up to 500 VA LVD(73/23/EC):EN 60335-1,EN 60335-2-51 Max.Input Voltage=32VDC Machine Safety(98/37/EC):EN ISO 12100 Digital Inputs: 2 Inputs&1 Output Operating Modes Logical»1«Voltage>8V,Logical»0«Voltage<2V Constant Pressure Control(Ap-c) Connector=RJ-45 Variable Differential Pressure Control Ethernet: (Ap-v)-factory default Services=http server and client,FTP server Proportional Pressure Control —o-••• B Minimum static inlet pressure at Constant Curve Duty(uncontrolled pump) pump suction port(PSI/bar)to avoid 1 I_ cavitation at fluid temperatures RPM Regulation ^'�= ��61 I Fluid VR15&VR20 VR25&VR30 Power Limitation(amps or watts) Temperatures (PSI/bar) (PSI/bar) :6-41® �, J 112°F(50°C) 7.3/0.5 4.35/0.3 Control Modes r: j� ki 176°F(80°C) 11.6/0.8 14.5/1.0 0 10Vdc in D --7- 1 230°F(110°C) 20.3/1.4 23.2/1.6 ModBus RTU Model Flange Size Power A B C D E F Weight Number (ANSI) (HP) in. mm in. mm in. mm in. mm in. mm in. mm lbs. Kg VR15-3 1-1/2" 0.027-0.680 9-13/16 250 15-3/16 386 12-5/8 321 7-13/16 198 7-7/16 189 10-1/16 255 57 26 VR20-3 2" 0.035-1.088 11 280 16-3/4 425 13-1/4 336 7-15/16 201 7-7/16 189 10-1/16 255 71 32 VR25-3 2-1/2" 0.054-1.496 13-3/8 340 17-11/16 449 14-1/2 369 8-11/16 221 7-7/16 189 10-1/16 255 82 37 VR30-3 3" 0.054-2.175 14-3/16 360 19-13/16 503 15-7/8 403 9-1/4 235 7-7/16 189 10-1/16 255 99 45 1 I,c us 4004896 Wg4"Cil FOR INDOOR USE ONLY CCOmfort SO/Ut/OnS® A Taco Family Company Taco Inc., 1160 Cranston Street,Cranston,RI 02920/(401)942-8000/Fax(401)942-2360 RE (E IVE 1' Taco(Canada)Ltd.,8450 Lawson Road,Unit#3,Milton,Ontario L9T 0J8/(905)564-9422/Fax(905)564-943 10/09/18 www.TacoComfort.com f y ► in ASPEN BUILDING DEPARTMENT 302-385 1DãCO Installation and Operation Instructions Comfort. Solutions- ATacoFamilyCompany VR15-3, VR20-3, VR25-3, VR30-3 SUPERSEDES:NEW EFFECTIVE:JUNE 23,2017 Plant ID No.001-3452 a' -- r ' ivJy... ay`/ or series RECEIVED ECM HIGH-EFFICIENCY CIRCULATOR 1-0-/0-9-/18 ASPEN BUILDING DEPARTMENT CONTENTS 1. Symbols and conventions used in this 13. Module layout 14 document 3 13.1 Connection considerations. 15 1.1. Abbreviations and conventions 3 13.2 Connection examples 16-17 2. Introduction 3 14. Control modes and priorities 18 Section 1 -Installation and Operation 4 14.1 Priority of settings 18 3. General Uses 4 14.2 Control variables. 18 4. Safety. 4 14.3 Module mode selection. 19 5. Pump Description 5 14.4 Mode 1 20 6. Use 5 Digital (switch)control 20-21 7. Pumped Fluids 5 0-10 VAC control. 22-23 8. Pump Installation 5 14.5 Mode 2 24 8.1. Motor Rotation Procedure 6-7 15. Relay output 24-25 9. Electrical Connections 8 16. Ethernet 26 10. Setup and Operation 8 16.1. Bus topology 26 10.1 Control Panel Layout 8 16.2. Connecting to pump ad-hoc. 26 10.2 Switching the Pump On and Off 8 16.3. Connecting to pump via router 26 10.3 Pump Functions 8 16.4. Pump configuration over Ethernet 26-27 10.4 Operation and Mode Selection 9 17. Modbus 28 10.5 Mode Description 9 17.1 Modbus related interface. 28 10.6 Restoring Factory Settings 10 17.2 Bus topology 28 11. Specifications 10 17.3 Connection to Modbus. 28 11.1 Application 10 17.4 Speed, parity and address. 28 11.2 Electrical Ratings 10 17.5 Termination 28 11.3 Standards, Protection and Flange Conn 11 17.6 Register block overview 29 11.4 Materials of Construction 11 17.7 Configuration register block. 29 17.8 Status register block. 30 Section 2 - Controller Operation 12 17.9 Pump control register block 31 12. Features 12 17.10 Pump status register block. ... 32 12.1 Specifications. 12 17.11 Pump data register block. 33 Modbus 13 18. Faultfinding 34 Ethernet. 13 18.1 Error codes 34 Mode Selection. 13 Analogue Signals 14 Performance Curves 35-36 Relay 14 Limited Warranty Statement 37 WARNING! AInstallation and use of this product requires experience and knowledge of this or similar products. Persons with reduced physical, mental or sensory capabilities must not use this product, unless properly instructed and supervised. Children must not be allowed to play with this product. A WARNING! "Ir7'r I) Prior to installation and commissioning, read these instructions first. Installation and operation must comply with local regulations. 10/09/ 8 2 ASPEN BUILDING DEPARTMENT 1.SYMBOLS AND CONVENTIONS USED IN THIS DOCUMENT WARNING! Denotes that a failure to observe those instructions might cause damage to equipment or pose danger to the user. 1.1 ABBREVIATIONS AND CONVENTIONS USED IN THIS DOCUMENT Abbreviation Description Baud, Baud rate Serial communication speed, in bits per second including start, parity and stop bits. CRC Cyclic Redundancy Check, additional bytes used to confirm valid data transmission. Ethernet IEEE 802.3, mostly referring to 10BASE-T RJ-45 connector present on board. H Differential pressure, often called Head. LED Light Emitting Diode. Modbus A serial communication protocol used for device automation and remote access. Q Pump flow or flow rate. RTU Remote Terminal Unit. RS-485 Multi drop serial network wiring, used to transfer Modbus data. For Modbus use, this manual assumes that the reader is familiar with commissioning and configuring of Modbus devices. It is also assumed that an existing Modbus RTU network on RS-485 wiring with Modbus master is present. For Ethernet and web interface use,this manual assumes that the reader knows how to configure or already has preconfigured Ethernet network. NOTE: • Data in this document are subject to change. • Actual implementation might differ by pump model and software revision. • Make sure you are using the right manual for your product. • Always verify that the pump is operating as desired after setup is complete. • Manufacturer cannot be held responsible for problems caused either directly or indirectly by the use of information in this manual. 2.INTRODUCTION This manual is broken down into two sections and describes the installation, operation and control module for VR15-3 through VR 30-3 range of pumps. Section 1 describes the installation and operation features. Section 2 describes the control module and its functions. RECEIVED 10/09/183 ASPEN BUILDING DEPARTMENT Section 1 . Installation and Operation 3. GENERAL INFORMATION, USES: The OOe VR 15 - VR30 circulating pumps are used for the transfer of liquid media within a closed-looped hot-water heating or air-conditioning hydronic system. They are designed as single or parallel main/standby operation variable- speed pumps, where the speed is regulated by an on-board electronic device. They are to be used with a water or glycol/water mixture. 4 SAFETY: These instructions should be studied carefully before installing or operating the pump. They are meant to help you with installation, use and maintenance and to increase your safety. Installation should be performed with regards to local or national standards. Only qualified personnel should maintain and service these products. Failure to comply with safety precautions could cause personal injury or machinery damage. AWARNING: Do not use in swimming pool or spa areas. Pump has not been investigated for these applications. AVERTISSEMENT: Ne pas utiliser dans une piscine ou un spa. La pompe n'a pas ete etudiee pour ces applications. WARNING: To avoid electrical shock, disconnect the power supply to the circulator and the main electrical unit. AFollow all local electrical and plumbing codes. AVERTISSEMENT: Pour eviter tout choc electrique,debranchez('alimentation electrique vers le circulateur et('unite electrique principale. Respectez tous les codes de plomberie et electriques locaux. AWARNING: Hot surfaces can cause burns.The motor can also reach temperatures that could cause injury. AVERTISSEMENT: Les surfaces chaudes peuvent provoquer des brulures. Le moteur peut egalement atteindre des temperatures qui peuvent entralner des blessures. CAUTION:The addition of petroleum based fluids or certain chemical additives to systems using TACO equipment Avoids the warranty. ATTENTION: L'ajout de liquides a base de petrole ou de certains additifs chimiques a des systemes utilisant un equipement TACO annule la garantie. ACAUTION: Use supply wires suitable for 90°C.ATTENTION: Employer des fils d'alimentation adeqauts pour 90°C. ACAUTION: Misconnection or overload of electrical or signal connections could cause pump to shutdown or cause permanent damage. ATTENTION: Toute erreur de raccordement ou surcharge des connexions electriques ou de signalisation peut en- trainer un arret de la pompe ou des dommages permanents. ACAUTION: Do not operate pump without the electrical cover securely attached. ATTENTION: Ne pas actionner la pompe si le couvercle electrique n'est pas correctement fixe. CAUTION:Pump motor,electronics enclosure and condensate drain openings should not be thermally insulated as it Acould interfere with cooling and condensate drainage. ATTENTION:Le moteur de pompe,('enceinte electronique et les ouvertures de drainage de conden � � miquement isoles car it peut y avoir interference avec('evacuation de condensat et de liquide de re 10/09/418 ASPEN BUILDING DEPARTMENT 5. PUMP DESCRIPTION: The high efficiency, electronically commutated 00e VR15- 30 model pumps consist of two main parts,the centrifugal pump and the electronic control.The hydraulic part is hermetically sealed from the motor assembly and has no mechanical seals. 00e pumps are powered by an electronically commutated permanent magnet motor(ECM) which does not consume energy to magnetize the rotor, providing superior energy efficiency. The ECM motor is run by an on-board frequency converter. The converter estimates current flow and head from the motor load, information essential for differential pressure control. 6. USE: All Taco 00e VR pumps are intended for circulation of solid-free fluid in pressurized, hot and chilled hydronic systems. The self-sensing ECM pump constantly calculates pressure and flow, and adapts its speed to the appropriate flow. 7. PUMPED FLUIDS: Use water and water/glycol mixtures only. Water/glycol mixtures must be HVAC-system compatible and should have no more than 50% concentration of glycol. The fluid shall not consist of aggressive or explosive additives and mixtures of mineral oils and solid or fibrous particles. The pump should not be used for pumping flammable, explosive fluids, and in an explosive environment. 8. PUMP INSTALLATION: The 00e(R) pump is protected with a double box during shipping. It can be lifted from the box with internal handles or by lifting it by the heat sink. ACAUTION: Pump may be heavy. Provide yourself help if needed. ATTENTION:La pompe est lourde.Veillez a deman-der de I'aide si necessaire. Pumps are designed to be installed using standard ANSI class 125 flanges. It is recommended that the 00e pumps be installed with at least 5 to 10 pipe diameters of straight pipe on the inlet and outlet of the pump. Use all nuts and bolts to attach companion flanges to the pump flanges. All VR model pumps should be installed with the axis in a horizontal position (see Figure 1). Failure to so may result in excessive noise and vibration. Desired pump orientation can be achieved by rotating the pump casing. The pump is mounted to the volute with four screws. By unscrewing those the head can be turned. See detailed Motor Rotation Procedure 8.1 elovy. Caution: When reassembling, care should be taken to avoid damaging the o-ring and insuring a tight seal RECOMMENDED INSTALLATION POSITIONS Figure 1: • Fset ■ice t r' . - - �� UNAUTHORIZED INSTALLATION POSITIONS „Sail A 16751 s wommm�i� I e � el' I� nnnuuuul, ATTENTION!! Installing pumps in UNAUTHORIZED positions may result in voiding the warranty. For replacement 0-rings, use part number 975-001RP. RECEIVED 10/09/18 5 ASPEN BUILDING DEPARTMENT FLANGE BOLT SIZES PUMP CLASS 150 ANSI FLANGE Model/Flange Size Bolt Hole Diameter Flange Thickness Bolt Hole Diameter Flange Thickness Minimum Bolt Size Quantity VR15 (11/2") 0.63 0.715 0.62 0.688 /"x 2Ya" 4 VR 20(2") 0.75 0.76 0.75 0.75 5/a"x 23/6" 4 VR25 (21/2") 0.75 0.76 0.75 0.875 5/a"x 25/a" 4 VR30(3") 0.75 0.84 0.75 0.938 %"x 21/2" 4 PERMITTED AMBIENT AND MEDIA TEMPERATURE: Ambient Fluid Temperature Ambient Fluid Temperature Temperature [°F] Min. [°F] Max. [°F] Temperature [°C] Min. [°C] Max. [°C] Up to 75 36 230 Up to 25 2 110 85 36 212 30 2 100 95 36 203 35 2 90 105 36 175 40 2 80 ATTENTION!! Operation outside recommended conditions may shorten pump lifetime and void the warranty. 8.1 Motor Rotation Procedure Caution: Motor is heavy! Caution: If system is filled and pressurized, shut off valve before and after the OOe.Allow to cool if system fluid is hot. 8.1.1. Notice! It is recommended to always change the orientation of the motor before installing pump in piping. • Tools Required: • 5/16" or 8mm ball-end hex wrench - _ • '/4" or 3/8"flat tip screw driver • . i • With motor in a vertical position, remove the 4 bolts (i11.1) • Using a flat tip screw driver, gently pry the motor and housing away from the pump housing ill. 1 • Once loosened, lift the motor off the pump housing, leaving behind the rotor/shaft assembly and seal. (ill. 2) 'J/q • The motor is now ready to be rotated into the desired position. • Before reinstalling the motor, check to make sure that the rotor/shaft is properly seated and the seal is properly positioned. (ill. 3) The flange of the rotor/shaft assembly must fit into the shallow groove (ill. 4) '' . A in the pump housing with the 0-ring accessible without removing the rotor/ ill. 2 shaft assembly. • If you determine that the assembly has moved, completely remove the 0-ring and the rotor/shaft assembly. • Reinstall the rotor/shaft assembly into the shallow groove and place the 0-ring seal in position as shown. (ill. 3) Spin the rotor, it should turn freely. • Turn the motor so the control box is in the desired orientation. Lift the motor, line up i11.3 the bolt holes and gently slip the motor over the rotor/shaft assembly being sure that the motor and rotor/shaft assembly are aligned. Once aligned the motor housing face will make contact with the pump housing face. NOTE: • Clearances between the pump housing and the motor housing are very tight. To ensure proper fit it is important to gently manuver the it � ' 111 rvill motor housing into the casing. DO NOT use force to insert the motor housing into the pump housing! oop, his • Insert the bolts and tighten in a cross pattern. • Install into piping and skip to 8.1.3 ill.4 ,! ED 10/09/618 ASPEN BUILDING DEPARTMENT 8.1.2 If the pump is already installed in the piping • Remove the 4 bolts (516" or 8mm hex wrench required) and try rotating the motor without backing it out from the pump casing. Try cracking the motor approximately .020" using a screwdriver between the motor and pump housing and try turning the motor. • If motor will not move, remove motor completely. Remove impeller, rotor, and rotor can from the motor. Note: Rotor and impeller assembly will come out first. Remove rotor can from motor and put aside. • Install impeller and rotor assembly into pump. • While holding rotor, install 0-ring in casing,and then slide rotor can over rotor and slide all the way in. • Rotor and rotor can should stay in place while you pick up the motor. If they do not, start over to assure 0-ring is properly located and have someone hold the assembly in place with a screwdriver on top of the plate. • Pick up the motor with the terminals properly orientated and carefully start to slide the motor over the rotor can. The resistance of the sliding will keep the rotor and rotor can assembly in place and the screwdriver can be moved. Note: Do not allow the motor to droop or the 0-ring might move out of position. • Line up the bolt holes, reinstall the bolts, and tighten in a cross-pattern. 8.1.3. After Installation into piping • Carefully open shutoff valves and check for leaks. • Make sure that the electrical box cover is mounted and that all cable glands are installed to prevent dust and particles from contaminating the electrical box. • Before starting the pump, the system (and pump) must be filled with fluid, and air completely bled out of the system. For proper operation, pressure must be maintained on the suction side of the pump.The pump does not have screws for bleeding the air, as it is automatically bled as a function of the design of the pump. Temporary air in the pump will generate noise that disappears after a short time. WARNING! • The maximum system pressure is 145 psi (1 MPa or 10 Bar) • The pump must always be filled with system fluid as it is water lubricated and water cooled • The motor stator openings and stator housing (Figure 7) should not be insulated since the thermal insulation may prevent motor cooling and prohibit condensate from escaping from the motor housing when used in high humidity environments where the fluid temperature is below the motor temperature. RECEIVED 10/09/18 7 ASPEN BUILDING DEPARTMENT 9. ELECTRICAL CONNECTIONS Connection of the pump must comply with local electrical codes and be carried out by qualified personnel. Connection to the power supply is carried out with the enclosed connector, the mounting of which is shown in the picture accompanying the connector. When connecting the pump,the following must be considered: • Liquid tight power connection required to maintain IP44 enclosure rating. Use supplied thread adapter option for flexible or armored cable installations. • The power input cable must use a minimum wire size of 16AWG solid or multi-strand copper wire. • Local or national electrical code requirements supersede Taco's specification. • Install an electrical disconnect to comply with national electrical code. • Connection of the power supply electrical cable must be done in a manner that ensures it does not contact the motor housing and volute of the device, due to potential high temperatures of both. The pump has built-in over current fuse protection, temperature protection, and basic overvoltage protection. It does not require additional overload protection devices unless required by local electrical codes. Power supply cabling should be capable of carrying rated power and be properly fused. Grounding connection is essential for safety and should be connected first. Grounding is only meant for pump safety. System piping should be grounded separately. 10. SETUP AND OPERATION: 10.1 Control Panel Layout 1. Bar Display of Values 2. Numerical Display of Values 0 3. Unit Display of the Currently Selected Parameter(Watts, Head Setting, Flow, or Speed) �g 00000o000 . 4. Display of the Currently Selected Mode 000000,0cp - 4 it 5. [+] Button °A Co p 6. [✓]Button 7. [-] Button 7 6 5j 10.2 Switching the Pump On and Off When the pump is powered for the first time, it operates with the factory default settings in automatic mode. To switch the pump off, press and hold the [-] key for 5 seconds, until OFF is shown on the display. When the pump is switched off, the numerical display shows OFF. To turn the pump on, press the [-] key briefly. 10.3 Pump Functions [-] Key Short press: • Turn pump on • Scrolling through parameters downwards, not changing parameter values. • Scrolling through modes downwards when mode selection is selected. • Changing parameters downwards when setting parameter values. Long press: • 3 seconds together with [+] key to select night setback mode. • 5 seconds to switch off the pump. • 5 seconds together with [I]and [+]keys to restore pump to factory default settings. [I] Key Short press: • To confirm currently selected values of both mode and parameter. Long press: RECEIVED • 3 seconds to enable mode selection. • 5 seconds together with long press on [+] and [-] keys to restore pump to factory deTe t§nigi 8 8 ASPEN BUILDING DEPARTMENT [+] Key Short press: • Scrolling through parameters upwards, not changing parameter values. • Scrolling through modes upwards when mode selection is selected. • Changing parameters downwards when setting parameter values. Long press: • 3 seconds together with [—] key to enable night setback mode. • 5 seconds together with[✓]and [—] keys to restore pump to factory default settings. 10.4 Operation and Mode Selection Once the desired mode is selected, the factory default parameter is displayed numerical display(except for Auto Mode). If required, the parameter value can be changed with the [+] or [—] key, then confirm the parameter setting by pressing the [✓] key. To activate or deactivate the night setback feature, simultaneously press and hold the [+] and [—] keys for 3 seconds. To scroll through the parameter values within a mode, use the [+] or [—] keys. The desired parameter is selected (see individual mode) with the [✓] key. The parameter value is then selected using the [+] or [—] keys. The selected value is confirmed using the [✓] key. 10 5 Mode Descriptions The pump can operate in 5 different modes.We can set the pump in the most appropriate mode,depending on the system where the pump operates. The pump modes are: • Automatic Mode(factory default) • Proportional Pressure (increased differential head as flow increases) • Constant Pressure(constant pressure as flow increased) • Constant Speed(user selectable to match system requirements) • Combined Mode(all mode indicators are off) To switch between modes (except night mode) press and hold the [✓]key for 3 seconds then select [+]or[—]key.Once desired mode is selected,press the[i]key to confirm. • H Automatic Mode In automatic mode the pump automatically sets the operating pressure, depending on the hydraulic Max Hset system. By doing so,the pump finds the optimal operating position. The parameters cannot be set;they can only be scrolled through.This mode is recommended in most systems. Hset'HQ% Proportional Pressure ► The pump maintains the pressure with relation to the current flow.The pressure is equal to the set Proportional Pressure pressure(Hset on the drawing)at maximum power; at 0 flow it is equal to HQ %(default 50%, HQ %can be set on the pump webpage)of the set pressure. In between,the pressure changes linearly, relative to H A the flow. In regulated mode we can only set the pump pressure(Hset on the drawing).We can only scroll through the other parameters. Constant PressureThe pump maintains the currently set pressure(Hset on the drawing),from 0 flow to maximum power, Min. where the pressure begins to drop.At constant pressure,we can only set the pressure(Hset on the drawing)which the pump will maintain.We can only scroll through the other parameters. Constant Pressure Constant Speed The pump operates with the currently set speed(RPMset on the drawing). In the unregulated mode,we H can only set the speed at which the pump will operate.We can only scroll through the other parameters. Combined Mode 4,„ Multiple limits can be set only over the web interface. None of the other modes are on. ASP NightMode • When the pump operates in night mode, it automatically switches between the selected Constant Speed operating mode and night curve. The transition to the night mode depends on the fluid temperature in the system.When the night mode is enabled, its icon illuminates and the pump operates in the selected operating curve of the mode.When the pump identifies the media temperature falling by 60 to 70 F° (15-20 C°)over a 2 hour time period, the icon IVED starts to blink and the pump switches to the night curve.When the fluid temperature rises again, the icon stops burn the pump switches to the operating curve in the selected operating mode. The night mode operates only in corn.i aidl the above indicated modes. It is not an independent operating mode. 10/0.9/18 ASPEN BUILDING DEPARTMENT 10.6 Restoring Factory Settings To restore factory defaults, press and hold all three buttons for 5 seconds. The pump will be set to the automatic mode of operation.Any previously set values for pressure and RPM will be deleted. 11.SPECIFICATIONS 11.1 Application: •Maximum Operating Pressure: 175 PSI (12 bar) • Water Temperature Range: 36°—230°F (2.2°— 110°C) •Ambient Operation Temperature Range: 32°— 104°F (0°—40°C). Ambient temperature should be 104°F (40°C) or lower when fluid temperature exceeds 194°F (90°C). • Relative Humidity: Max. 95% • Designed for closed loop heating and cooling systems pumping water or a water/glycol mixture. • NPSHr-Minimum static inlet pressure at pump suction to avoid damage to the bearing assembly: FLUID VRI5&VR20 VR25&VR30 TEMPERATURES (PSI/bar) (PSI/bar) 112°F(50°C) 7.3/0.5 4.35/0.3 176°F(80°C) 11.6/0.8 14.5/ 1.0 230°F(110°C) 20.3/ 1.4 23.2/ 1.6 • For indoor use only- employer uniquement a l'interieur. 11.2 Electrical Ratings: 1 phase,110-240V,47-63Hz(VR15&VR20) Pump Ratings 1 phase,2 30-240V,47-63Hz(VR25&VR30) VR15=0.027-0.68 HP PowerConsumption(HP) VR20=0.035 1.088 HP VR25=0.054-1.496 HP VR30=0.054-2.175 HP VR15=20-500W PowerConsumption(W) VR20=26-800W VR25=46-1100W VR30=40-1550W VR15=5.6-2.8A Rated Current VR20=7.2-3.6A (lphase,230V) VR25=5.3A VR30=7.2A VR15&VR20=6A Current Limit(Max.) VR25&VR30=8A 24VSuppI Output Max.Current upto100mA,0utputVoltage of24V±20%,Output Ripple under 1V RelayOutput: 8A,Max.Voltage 250VAC, 48VDC Max. Load upto 500VA Max.InputVoltage=32VDC Digital Inputs: 2 Inputs&1 Output Logical»1«Voltage>8V,Logical»0«Voltage<2V Con n ector=RJ-45 Ethernet: Services=httpserverand client,FTP server RECEIVED 10/09(018 ASPEN BUILDING DEPARTMENT 11.3 Standards, Protection and Connection: • Insulation:ClassH • Enclosure:Class2,IP44 • Integrated Motor Protection(electronically protected) • Continuous Duty • UL778,1004-1,508C • CAN/CSAC22.2#108,#100,#107.1EMC(89/366EEC):EN61000 • LVD(73/23/EC):EN60335-1,EN60335-2-51 • Machine Safety(98/37/EC):EN ISO 12100 • FlangeConnections:ANS14-bolt 11.4 Materials of Constructin: • Casing Cast Iron,Cataphoresis Coated • Impeller Stainless Steel • Shaft Stainless Steel • Bearing Metal Impregnated Carbon RECEIVED 10/09/18 11 ASPEN BUILDING DEPARTMENT Section 2. Controller Operation 12. FEATURES This section describes the controller features for VR15-3 through VR 30-3 range of pumps. The controller is used for various remote control applications, including: • Remote on/off • Analog 0..10 V voltage control • Modbus remote control • Status relay feedback • Web access over Ethernet There are several possible connection configurations. Not all functions can be used simultaneously. — • on/off + 0..10 V + relay output 11 • Modbus RTU + Relay output • Ethernet + on/off + 0..10 • Modbus RTU + Ethernet • Ethernet + on/off + relay output N 12.1 Specifications Below is an overview of Controller specifications. For details, please refer to appropriate sections of this manual. GENERAL DATA Ambient humidity <95% relative, non-condensing Also see appropriate pump data for other ambient specifications. Power supply and 5 V@500 mA supplied by the pump 6-pin connector further extended for display. connection RECEIVED 10/09/18 12 ASPEN BUILDING DEPARTMENT MODBUS SPECIFICATIONS Data protocol Modbus RTU Modbus connector Screw-less terminals 2+1 pins. See section 16.3"Connection to Modbus" Modbus connection type RS-485 Modbus wire configuration Two-wire+common Conductors:A, B and COM(Common). See section 16.3"Connection to Modbus". Communication transceiver Integrated, 1/8 of standard load Connect either via passive taps or daisy chain. Maximum cable length 1200 m See section 16.5"Termination". Slave address 1-247 Default is 245, settable over Modbus. See section 16.4"Speed, parity and address". Line termination is not integrated. For low Line termination Not present speed/short distance,termination can be omitted. Otherwise, terminate the line externally on both ends. Supported transmission 1200,2400,4800,9600, Settable over Modbus register[default=19200]. speeds 19200, 38400 baud Start bit 1 Fixed. Data bits 8 Fixed. Stop bits 1 or 2 1 stop bit minimum, up to 2 when parity not enabled [default=1] Parity bit Even/odd/none [default=Even] Flashing yellow when data reception detected. Modbus visual diagnostics LED2 Combined (OR)with Ethernet ACT function. Maximum number of Limited by possible Modbus addresses to 247. Modbus devices 247 1/8 nominal load enables 256 devices. Maximum Modbus packet size 256 bytes Including address(1)and CRC(2)bytes. Isolation Common ground (COM) Modbus shares common ground with other signals. with SET1, SET2 and SET3. ETHERNET SPECIFICATIONS Ethernet connector RJ-45 10BASE-T, 10Mbit/s connection. Connection type - Web server(port 80) and services - Firmware update over web interface - Optional Modbus RTU over TCP/IP Default IP address 192.168.0.245 192.168.0.246 for right twin pump. Ethernet visual LED1 /LINK Slowly blinking when module is powered, permanently lid diagnostics when link established. LED2/ACT Flashing yellow when data reception detected. Combined (OR)with Modbus data reception indication. MODE SELECTION SWITCH Adjustment 10 position rotary switch Position read at power-on. Used for relay configuration and module configuration reset. RECEI Eta 10/09/18 13 ASPEN BUILDING DEPARTMENT Analog signals(SET1,SET2, SET3) Input voltage range -1 to 32 VDC When used as input. Output voltage range 0 to12 V When used as output. 5 mA max. Load allowed per output. Input resistance -100 kO2 0.5 mA load is added for most configurations. Output current sink range 0 to 33 mA(4-20 mA) Current sink to COM if configured as output. Relay specifications Connection type Screw-less terminals Rating - 250 VAC,8A Potential free changeover contact. 48VDC, Max Load Upto 500VA 13. CONTROLLER LAYOUT T T ETHERNET LED2 LED1 ACT LINK MILANI ZZOZ0 _ , �,�� lie ro i•��a Cam~^ > m x >Z z z LL a + .:, cc o o= MODE Z Ll W` � - am ry I_ m 0 v ovv)i 0u C a Z RELAY ANALOG RS 485 L — — — L Terminal Designation Description MODE Mode selection rotary switch. Used to configure mode of operation for the circuit.See section 14.3"Module mode selection" LED1 /LINK Slowly blinking when module is powered. Blinking fast when Modbus Error. Permanently lid when Ethernet link established. Ethernet 10BASE-T RJ-45 connector. LED2/ACT Indicates Ethernet activity or Modbus activity. B/D- RS-485 negative data signal for Modbus. A/D+ RS-485 positive data signal for Modbus. SET1 /RUN Control signal 1. COM/OV RS-485 common and analog input common(ground). SET2/MAX Control signal 2. SET3/FB Control signal 3. NC Normally closed relay contact.Opens when relay is active. C Relay common contact. NO/OK Normally open relay contact.Closes when relay is active. RECEIVED 10/09/18 14 ASPEN BUILDING DEPARTMENT 13.1 Connection Considerations • All cables connected must be heat-resistant to at least+185 °F. • All cables connected must be installed in accordance with The National Electric Code/NFPA 79/ EN 60204-1. • All wires to the communications module must be connected to the terminals or cut. No loose wiring permitted. WARNING! A • If voltages over 24 VAC/DC are possible on NO, C, NC terminals: • Wires should be routed so no wire crosses the center barrier. • Relay cable (NO, C, NC) must be separated from all other wiring with reinforced insulation. • Cable outer layer must not be stripped longer than 0.59 inches. See"Cabling preparation" below. WARNING! Before performing any work on the module, make sure that the pump and module electricity supply has been switched off and that it can- not be accidently switched on. RECEIVED 10/09/18 15 ASPEN BUILDING DEPARTMENT 13.2 Connection Examples DEFAULT(FACTORY)CONFIGURATION T r— - ETHERNET LED2 LED1 ACT LINK HZLII COO punk Z2121 z z N f a a m o o MODE r Z G' Z rn '"' w OO m C 0 C A Z 0 RELAY ANALOG RS-485 L - - - - L - L - - - 1 RELAY AND MODBUS CONNECTION ETHERNET LED2 LEDI ACT HNK ZCV1 Ali [a �-�'oo is-;_]] ~" t'S 1 0`J` 1'. ` z 2 > - g O g ♦ MODE d" m C 0 " 0 u D Z 0 I I ALARM Max Modbus signal Run RECEIVED 10/09/18 16 ASPEN BUILDING DEPARTMENT RELAY AND ETHERNET CONNECTION — - - - - - - - - - - - -I ETHERNET LED2 LED1 ACT LINK 1771 ©2I/IV;� ❑❑❑ ❑ ❑❑ C❑❑ S1 000 0003C COC _ ,) 0000C i u z > m 8 E MODC c o a z c O LI W o o 0 c z 0 r , , NOTE: 7/8"max length Ethernet connector recommended. The Ethernet connection has a sharp cable bend angle and reducing the connection terminal length reduces this problem. NOTE:To maintain pump IP protection, the network cable should be pulled through the gland inlet and then crimped to a connector. RECEIVED 10/09/18 17 ASPEN BUILDING DEPARTMENT 14. CONTROL MODES AND PRIORITIES 14.1 Setting Priority Several signals will influence the pump operation. For this reason, settings have priorities as shown in the table below. If two or more functions are active at the same time, the one with highest priority will take precedence. Priority Pump control panel & External signals' Modbus control Ethernet settings 1 Stop (OFF) 2 Night mode active2 3 Max. RPM(Hi) 4 Min. curve4 5 Stop(Run not active) 6 Max. curve' Stop3 7 Set point setting4 Set point setting3 8 Set point setting4 Examples: • Stop on the pump display panel will stop the pump, regardless of external set point. • If External Run input is inactive,the pump cannot be started over Modbus, but can be set to max RPM on the display panel. 14.2 Control Variables Pump will respond to external controls according to selected pump operating mode. Consult proper pump operating manual for explanation. Symbol Regulation mode Module set point controls: Auto mode (RUN ONLY) OProportional pressure Maximum head ;,L} Constant pressure Maximum head Constant speed Speed (RPM) Combined5 (Web interface only) ONight mode6 (RUN only) 'Not all inputs are available in all modes. 2External and Modbus Stop signals become active in night mode. Due to possible confusion, use of night mode is discouraged while using external control. 30n1y available when pump is bus controlled. 'Not available when pump is bus controlled. 'Multiple limits can be set. Not available on all pumps. RECEIVE') 'Night mode is not independent regulation mode. 10/09/18 18 ASPEN BUILDING DEPARTMENT 14.3 Module Mode Selection WARNING! Before performing any work on the module, make sure that the pump and module electricity supply has been switched off and that it cannot be accidently switched on. There is a mode selection rotary switch in the terminal box. It can be rotated by gently inserting a screwdriver into the arrow mark on top and rotating the switch to desired value. Mode switch Function Description position 0 Free configuration Terminal functions are configured over Ethernet interface. SET1 = RUN input SET2 = MAX input Mode 1 SET3 = FB(10.5 V)output, used to supply RUN and MAX inputs. 1 Factory Default External voltage source can also be used. RS-485 = Modbus interface. See section "14.4 Mode 1". Application: 0-10 VDC Speed or head control,external OFF SET1 = RUN input SET2 = SPEED input 2 Mode 2 SET3 = FB(10.5 V)output, used to supply RUN and MAX inputs. External 5-24 V voltage source can also be used. RS-485 = Modbus interface See section "14.5 Mode 2". 3...5 RESERVED Reserved for future or customer specific use. 6 Show relay LED1 and LED2 will show relay configuration. configuration See section "5 Relay output". Relay configuration will be increased (0->1, 1->2, 2->0)when electricity is turned on. 7 Change relay LED1 and LED2 will show current relay configuration. configuration See section "5 Relay output". Same as Mode 9,with exception of: 8 Twin reset to factory module IP address is set to 192.168.0.246 Twin IP address is set to 192.168.0.245 This mode will set communication interface to default values. Main purpose is to restore default settings. NOTE: • Disconnect any SET1, SET2 and SET3 connections when using this mode to 9 Reset to factory prevent possible harm to controller. SET1, SET2, SET3 will output test voltages of 10 V,7 V and 5 V respectively. RS-485 port is actively driven. Relay will cycle. This is used for testing purposes. • It is recommended that all module wires are disconnected to prevent possible harm to external controllers. RECEIVED 10/09/18 19 ASPEN BUILDING DEPARTMENT 14.4 Mode 1 Mode 1 is most often used mode of operation. It has 2 pre-prepared inputs that can be used for either digital control or with analog control voltages.Additional 10.5V output provides voltage feedback for analog or digital control. Terminal designation Signal function SET1 /RUN RUN input. Signal load 0.5 mA. COM/OV Common ground for voltage input. SET2/MAX MAX input. Signal load 0.5 mA SET3/FB 10.5 V feedback voltage for SET1 and SET2. DIGITAL(SWITCH)CONTROL COMMON MODE 1 CONNECTION CONFIGURATIONS(SWITCH) ETHERNET LEDT LED1 ACT UNK i o_ ut__1© iii 2 O 00 1Z viaLi p V V O ? n 2 t 3 • . MODE rygt oommAm O 'SC $ s o c z r O L - - - -L — L _ 1 _ _ _ _I —\• Max —\. Run RECEIVED 10/09/18 20 ASPEN BUILDING DEPARTMENT Contact position Function Description RUN MAX SET 3/FB SET 3/FB Stop the pump The pump is stopped 1 l _ SET 1/RUN SET 2/MAX SET 3/FB SET 3/FB Start the pump The pump will run with internal set point Q_____. SET 1/RUN SET 2/MAX Minimum curve The pump will run with minimal speed for selected regulation mode I Q. Maximum curve The pump will run with maximum speed form selected regulation mode :".'.....** Q� RECEIVED 10/09/18 21 ASPEN BUILDING DEPARTMENT ANALOG(SWITCH)CONTROL OPTIONAL MODE 1 CONNECTION CONFIGURATIONS(ANALOG) ETHERNET ETHERNET LED2 LED1 LEG? LE D1 ACT LINK ACT UNI, IIII r > IM -*- Cocoa ��: �5.�) OCR Oil• ��� r . MODE > if Z 8 S MOUE ry s ry2 2 — gE o u ,� yf ° L.,— � J I L --rI— RUN 0-V1 RUN ,— r E THE RNE1 I tIHERNtI LEDI LED! I LT D2 LED1 ACT UNK ACT LINE —......_— D E ❑c❑❑❑ ill s.,. ❑❑❑D❑ CO2 cxx c ,. 11 M O � ) I CCICC 7 CX)C :J fe N , n ilt I ' m 8S ry L MODE 2 N Q Nm om c - ry 8 E or B s i , I_ _ I- - a-a RECEIVED 10/09V218 ASPEN BUILDING DEPARTMENT RUN voltage MAX voltage Function <2 V < 1 V Pump stopped > 3 V < 1 V Internal regulation <2 V 2..10 V Minimum curve > 3V 2..10V H [m] /• n[RPM] H max/ Hmax H/ n � [ Halm/ nmin I Hmin= 15%Hmax nmin=25%Hmax Off 1 2 3 10 U[V] Figure 1: External 2..10 V transfer curve for Mode 1 0..10 V H [m] /A (RUN+MAX) n[RPM] H max/ Hmax Hmin/ nmin I t Hmin= 15% Hmax Inmin = 25% Hmax Off I 1 2 3 10 U[V] RECEIVED Figure 2: External 0..10 V transfer curve for Mode 1 10/09P18 ASPEN BUILDING DEPARTMENT 14.5 Mode 2 Mode 2 is used for external 0..10V voltage control. Terminal designation Signal function SET1 /RUN RUN input. Signal load 0.5 mA. COM/OV Common ground for voltage input. SET2/MAX SPEED input. Signal load 0.5 mA SET3/FB 10.5 V feedback voltage for SET1 and SET2. MODE 2 CONNECTION CONFIGURATIONS LID` uoi i b< uoa PUN RUN voltage MAX voltage Function <2 V 0..10 V Pump stopped >3V 0..10V H[m] n[RPMr Figure 3: External 0..10 V transfer curve for Mode 2 Hm./nm.. Hmin=15%H„,„ =25%n„. Hmn/nmin Off 0.5 10 u[v] 15. RELAY OUTPUT Terminal designation Terminal description MODE Mode selection rotary switch. Used to show and configure mode of operation for relay. LED1 /LINK Slowly blinking when module is powered, permanently lid when link established'. LED2/ACT Flashing yellow when data reception detected. Combined (OR)with Modbus data reception indication'. NC Normally closed relay contact.Opens when relay is active. C Relay common contact.NO/OK Normally open relay contact. Closes when relay is active. RECEIVED The module contains one status relay, used to signal pump operation or malfunction. See table following for functionality. 10/0 9118 ASPEN BUILDING DEPARTMENT Relay Output Relay LED status' configuration status Description position LED 1 LED 2 0 Error Only active when the pump is powered up and detects a problem O [default] with operation. �O 1 NC NO C 1 1 Ready The relay signal is active when the pump is ready for operation. Q �O NC NO C I 1 1 2 Operation The relay signal is active as long as the pump is operating. If the / .O. .O pump comes to a stop or an error occurs, relay will deactivate. / 1 / 1 NC NO C Relay output not active. NC NO C Relay configuration number can be modified by either the web interface, Modbus register 012 or the Mode switch. 16. . ETHERNET Terminal designation Description MODE Can be used to reset network configuration LED1 /LINK Slowly blinking when module is powered, permanently lid when link established. Ethernet 10BASE-T RJ-45 connector. LED2/ACT Indicates Ethernet activity or Modbus reception. The communications module has a built in web server which allows you to access your pump directly from an existing Ethernet network. Direct connection to a computer is also possible with a crossover cable. The web server uses HTML pages to set/view: • Regulation mode settings • Regulation parameters(power, RPM, head,flow,efficiency) • Relay settings • External control inputs • Current and previews error • Pump statistics(power consumption, run time and other). 'When mode Mode 6 or Mode 7 is selected, LED1 and LED2 will show relay configuration. See section "4.3 Module mode selection" ♦ / LED is on / ♦ LED is off O RECEIVED 10/09/18 25 ASPEN BUILDING DEPARTMENT 16.1 Bus Topology 111 -T Figure 4: connecting to a computer with a crossover cable Figure 5: connecting to a network via router 16.2 Connection to a Pump Ad-Hoc When connecting directly with the computer, Ethernet must be used to connect with the pump.The pump can then be accessed by typing IP address"192.168.0.245"or"00e" (or"192.168.0.246"or"00e2" if it is a left twin pump)in to your web browsers address bar. The computer must be set up to have a dynamic IP address. 16.3 Connection to a Pump via Router When connecting via a router, Ethernet must be used to connect with the pump. The pump can then be accessed by typing IP address"192.168.0.245"or"00e"or"192.168.0.246"or"00e2" if it's a left twin pump in to your web browser's address bar.The computer must be set up to have a dynamic IP address. 16.4 Pump Configuration over Ethernet Pump configuration is possible via HTML pages that offer different options: 1. Overview(default page when you connect to the pump,web page OVERVIEW)displays pump operation summary i.e.: • Operating mode, • Power consumption, • Head, • Estimated flow, • RPM • Estimated efficiency, • Priority set point, • Mode switch position • Input/output status • Replay status • Error code •Twin pump status • Night mode status • Motor temperature • Heat sink temperature, • Number of restarts. RECEIVE') 10/09/18 26 ASPEN BUILDING DEPARTMENT 2. Pump settings(web page PUMP) is meant to provide regulation and control (input and output)settings. It has control over: • Operation mode • Head limit(depending on pump mode) • RPM limit(depending on pump mode), • Ratio between head and flow HQ (depending on pump mode) • Input/output control. • Relay control. Setting can be saved to permanent memory by pressing the SAVE button. 3. Network settings(web page NETWORK)provide a way to change network configuration: • NetBIOS name-is a local network name service. Instead of'192.168.0.245'you can for example use 'http://00e'. Default: 00e, • Pump IP address- is a pump network address.The pump is seen as http server on this address, default: 192.168.0.245, • DHCP server- provides lease for"point to point"connection (cross-over cable to computer for example).Will disable itself if another DHCP server is found, • DHCP client will automatically acquire DHCP address from the network, • Default gateway—provides connection route to larger networks.This is usually a router address, default: 192.168.0.1, • Subnet mask-sets subnet address range that is on the same subnet and can be reached directly.The rest of communication goes over the gateway, default: 255.255.255.0, • Twin mode with IP- will connect two pumps for alternating operation. When two pumps are configured for twin mode, they will switch about once per day. Setting this field to inexistent IP will disable this option! Set it so the first pump references the second and vice versa. Default: 192.168.0.246. Setting can be saved to permanent memory by pressing the SAVE button. 4. Log (web page LOG)displays possible previous and current errors. 5. MORE(web page MORE) has link to additional manuals and tools that might be available. Has an option to update NMTC modules software, by user inputted software file(available at your local serviceman or our webpage). RECEIVED 10/09/18 27 ASPEN BUILDING DEPARTMENT 17. MODBUS 17.1 Modbus Related Interface Designation Description MODE Can be used to reset network configuration. LED2/ACT Indicates Ethernet activity or Modbus reception. B/D- RS-485 negative data signal for Modbus. A/D+ RS-485 positive data signal for Modbus. COM/OV RS-485 common and analog input common (ground). 17.2 Bus Topology The VR Control is a Modbus slave, connected directly to a Modbus RTU network. Connection can be made in either daisy chain style (if cabling allows such a connection)or a limited length passive tap. Schematic example is in Figure 6. Slave 1 Master Slave 2 Slave 3 1=1r r°r ro o' Passive tap Daisy chain ' Figure 6: Example of Modbus network Typically,only one master device is connected to the serial bus, and one or several slaves are also connected to the bus. Slaves do not communicate with each other and will never transmit data without receiving a proper request from the master device. Up to 32 single load devices can be connected to one RS-485 Modbus system without using a repeater.As this module is a 1/8 load device, up to 256 modules can be connected to the bus. Repeaters can be used to extend the maximum transmission distance and increase device count if needed. 17.3 Connection to Modbus A screened, twisted-pair cable should be used. The cable screen must be connected to the COM terminal and connected to safety ground at one point. 17.4 Speed, Party and Address By default, each device is set to 19200-E-1 (even parity), address 245. Properly set registers in section "7.7 Controller Configuration register block"to configure each device before connecting it to existing network. Optionally power each device one by one, configuring the settings before adding an-other one. There are several ways to restore forgotten Modbus connection settings: 1) Configure the module over Web interface. See section 6"Ethernet". 2) Reset the module to factory defaults. See Mode 9, section "4.3 Module mode selection". 3) If only address is unknown, Modbus"broadcast" (0x00)address can be used to write new address. Use care- fully as the value will be written to all connected devices. 17.5 Termination Control module contains neither termination nor bias circuitry. RS-485 wiring should be externally terminateREeEIVED 10/09/18 28 ASPEN BUILDING DEPARTMENT For short wiring and/or low baud rate, interface can operate without termination. However it is recommended that termination (-150 ohm resistor) is added on both ends of bus wiring. There are wiring length limits regarding to speed and termination: Maximum speed [baud] Maximum cable length [ft] 38400 4000,terminated cable 9600 4000 19200 1800 38400 900 NOTE:Any branch/derivative cable is considered unterminated. Keep them short, below 250m combined for maximum speed and reliability. 17.6 Register Block Overview Controller Modbus RTU registers are grouped in the following register blocks: Start address Register block Readable/Writable Description 001 Controller configuration R/W Configuration of the Controller module. 021 Controller status R Status registers for the Controller module. 101 Pump control R/W Pump control registers. 201 Pump status R Status data from the pump. 301 Pump data R Measured data from the pump. All addresses contain 16 bit(one Word) registers. Some are bit interpreted while others are combined for a 32 bit value. NOTE: All register addresses are 1-based.Address 001 is thus transmitted over bus as 0x0000. 17.7 Controller Configuration Register Block Registers in this block are read with either function codes 0x03 or 0x04.They can be written as holding registers with function codes 0x06 and Ox10. NOT :All values in this block are stored in nonvolatile memory immediately after write. NOTE: See section "4.3 Module mode selection" and use Mode 8 or 9 to restore default settings if you cannot access the controller after writing to these registers. RECEIVED 10/09/18 29 ASPEN BUILDING DEPARTMENT Address Register name Range Resolution Description 001 SlaveDelay 0..10000 1 ms Delay in milliseconds for slave reply.This delay will be added to every Modbus reply[default=0]. 002 RESERVED 003 ModbusAddress 1..247 1 Modbus address[default=245]. Modbus transmission speed enumeration. 0 = 1200 baud 1 =2400 baud 004 BitRate 0..5 1 2 =4800 baud 3 = 9600 baud 4 = 19200 baud [default] 5 = 38400 baud 005..008 RESERVED Parity setting to be used for communication. 009 Parity 0..2 1 0 = No parity 1 = Even parity[default] 2 =Odd parity Stop bits used for communication.2 stop bits will only be 010 StopBits 1..2 2 used when "Parity"is set to 0. 1 = 1 stop bit[default] 2 =2 stop bits 011 RESERVED Configures module relay output. 0 = indicates fault 012 RelayControl 0..2 1 1 = indicates pump ready 2 = indicates pump operation See section "5 Relay output". 17.8 Controller Status Register Block Registers in this block are read with either function codes 0x03 or 0x04. They are read-only.This block can be used for various kinds of fault finding. Address Register name Resolution Description 021..022 RESERVED 023 SoftwareVersion 0.1 Module software version 024..029 RESERVED 030 ProductVersion 1 Product version [32x for NMTC module,x denotes hardware revision] 031 RESERVED 032 SoftwareVersion 0.1 Module software version [10= 1.0] RECEIVED 10/09/18 30 ASPEN BUILDING DEPARTMENT 17.9 Pump Control Register Block Registers in this block are read with either function codes 0x03 or 0x04. They can be written as holding registers with function codes 0x06 and Ox10 Address Register name Range Description 101 ControlReg b0: Control bit that sets local or remote control. Setting this bit will enable pump RemoteAccess control over Modbus. 0 = Local 1 = Remote(controlled by Modbus master). b1: Control bit that switches the pump on or off. OnOffReq 0 = Off(stop) 1 = On (start). b2..15: - RESERVED 102 AltControlMode Alternative Control mode. Use of register 108 is preferred. Sets the control mode enumeration. 0 =ConstantRPM 1 =ConstantRPM 3 =ConstantHead 4 =ConstantHead 5 =ConstantHead 6 = ProportionalHead 128 =AutoHeadMode NOTE:values outside this range reserved. 103 OperationMode RESERVED 104 SetPoint 0.. Sets desired pump set point. 10000 0 will stop the pump. 10000 will set the pump to maximum output for desired mode. Values outside of valid range will cause the pump to operate with front panel set values. 105 RelayControl 0..2 Configures relay output. 0 = indicates fault 1 = indicates pump ready 2 = indicates pump operation See section "5 Relay output". 106...107 RESERVED 108 ControlMode 0..3 Sets the pump control mode. 0 =AutoHeadMode(Automatic head mode) 1 = ProportionalHead (Head proportional to flow) 2 = ConstantHead (Head is kept constant) 3 = ConstantRPM(Speed is kept constant) NOTE:values outside this range reserved. See section"4.2 Control variables"for exact parameter to be controlled. RECEIVED 10/09/18 31 ASPEN BUILDING DEPARTMENT 17.10 Pump Status Register Block Registers in this block can be read by means of function codes 0x03 and/or 0x04.They are read-only. Address Register name Description 201 StatusReg b0..b5: - RESERVED b6: Rotation Indicates if the pump is rotating (running)or not. 0= No rotation 1 = Rotation. b7: RESERVED Bit 8: Indicates if the pump is locally or remotely controlled. AccessMode 0 = Local (a source with higher priority controls the pump) 1 = Remote(controlled by Modbus master). Bit 9: IsOn Indicates if the pump is on or off. 0=Off 1 =On It not necessarily indicate rotation as an error might stop the pump. Bit 10: Error Indicates if there is a problem with proper operation. 0= No problem 1 = Error present. Pump might still run. Bit 11: - RESERVED Bit 12: - RESERVED Bit 13: Indicates if the pump is running near maximum speed. NearMaxSpeed 0 = No 1 =Yes. This flag is set when power or speed is over 95%of rated maximum. Bit 14: - RESERVED Bit 15: Indicates if the pump is running near minimum speed. NearMinSpeed 0= No 1 =Yes. This flag is set when speed falls below 1/3 of rated maximum. 202 RESERVED (TBD) 203 ControlMode Indicates the actual control mode. 0= ConstantRPM 1 = ConstantRPM 3=ConstantHead 4=ConstantHead 5= ConstantHead 6= ProportionalHead 128=AutoHeadMode. 204 RESERVED 205 ErrorCodel Current first error code. 0-when pump is operating without problems. This value will always be non-zero when there is an error RE section"8.1 Error codes"for code details. eEIED 10/09/18 32 ASPEN BUILDING DEPARTMENT 206 ErrorCode2 Second error code. Non-zero when there is more than one error. See section "8.1 Error codes"for code details. 207 ErrorCode3 Third error code. Non-zero when there is more than two errors. See section "8.1 Error codes"for code details. 208 Control Mode Indicates the actual control mode. 0=AutoHeadMode(Automatic head mode) 1 = ProportionalHead (Head proportional to flow) 2= ConstantHead (Head is kept constant) 3= ConstantRPM(Speed is kept constant). NOTE: values outside this range reserved. See section"4.2 Control variables"for exact parameter to be controlled. 17.11 Pump Data Register Block Registers in this block can be read by means of function codes 0x03 and/or 0x04.They are read-only. Modbus Register name Range Resolution Description address 301 Head 0.01 m Pump head estimation in meters of water column. 302 Flow 0.1 m3/h Pump flow estimation. 303 Efficiency 0.01 % Estimated pump efficiency. 304 Speed 1 rpm Motor speed. 305 Frequency 0.1 Hz Motor frequency [100.0 Hz for 3000 rpm and 4 pole motor]. 306..307 RESERVED 308 ActualSetPoint 0..10000 0.01 % Indicates actual set point of the pump. (-1 for internal pump regulation). tbd 309..311 RESERVED 312 PowerHl 0..232 1 W Total power consumption of the system. 313 PowerLO 314..317 RESERVED 318 CircuitTemp -5500.. 0.01 °C Power electronics hotspot temperature. 16000 319 MotorTemp -5500.. 0.01 °C Motor compartment temperature. 16000 320..321 RESERVED 322 LiquidTemp -5500.. 0.01 °C Liquid temperature. 16000 323..326 RESERVED 327 OperationTimeHl Total operation time(above zero speed)of the 328 OperationTimeLO 1 hour pump.8 329 TotalPoweredTimeHl 1 hour Total power-on time of the module.8 330 TotalPoweredTimeLO 331 RESERVED 332 EnergyHl 333 EnergyLO 1 kWh Total energy consumption of the system.8 RECEIVED 8 Not available on all models. 10/0 9/18 33 ASPEN BUILDING DEPARTMENT 18. FAULT FINDING 19.1 Error Codes The following codes will show up on display panel and on the appropriate Modbus registers to help you diagnose the cause of improper operation. Error code Description Probable cause E1x Load errors E10(drY) Low motor load Low load detected. Pump is running dry. El1 High motor load Motor might be faulty or viscous medium is present. E2x Protection active E22(hot) Converter temperature limit Circuit is too hot and power was reduced to less than 2/3 of rated power. E23 Converter temperature protection Circuit is too hot to run, pump stopped. E24 Converter overcurrent Hardware overcurrent protection triggered. E25 Overvoltage Line voltage is too high. E26 Undervoltage Line voltage is too low for proper operation. E3x Pump errors E31 Software motor protection active Average motor current was too high, pump load is much higher than expected. E4x Device specific error codes Electrical circuitry did not pass self-test. E40 General frequency converter error One of the display segment diodes is faulty(open/short). E42(LED) LED faulty Display board does not detect proper connection to main board, but power supply is present. E43 (con) Communications failed Voltage on DC link shunt(R34)not in expected range. During MFG.TEST,this is 10 kf2, 1% E44 DC link current offset resistor for 10°C..30 °C During operation, expected values are-55 °C..150 °C. E45 Motor temperature outside limits During MFG.TEST,this is 0°C..50°C.During operation, expected values are-55°C..150 °C. E46 Circuit temperature outside limits During MFG.TEST,this is 0°C..50°C. During operation, expected values are-55°C..150 °C. E47 Voltage reference outside limits. Comparison between internal references does not match. E48 15V outside limits 15 V supply not 15 V. E49 Test load does not match No test load detected or current measurement does not work properly(MFG.TEST). E5x Motor error codes E51 Motor parameters out of range Motor does not operate as expected. E52 Thermal Protection Active Motor Temperature is too high. Pump not operating E53 Invalid Model Selected Pump model not valid or out of range RECEIVED 10/09/18 34 ASPEN BUILDING DEPARTMENT immi=s 00e► VR15-30-3 ECM High-Efficiency Circulators Waell 00.:.:, Carla t_teS ltitio s- PERFORMANCE A hw Gann/Company (Ipm) 0 100 7,00 300 40,0 50 _ • _ 1 . 45 = VR15-3 - 40 - • - 1.: 35 = - 10 30 = - 8 ^ 'a 25 t.,. E ea 1 20 = . .... ... ...: .. ........ ....................................... ......... 6 15 = 10 5 = . - ,... - 2 0 -. ......... ....... . ....... ...... . ....... . ....... ......... , ........ 0 0 10 -20 3,0 •1C 50 00 712, 80 ,_,C 100 110 120 Flow (gpm) (Ipm) 0 100 20,0 300 4_,0 500 600 700 50 l I I I I I 1 I • 45 - 14 40 . - • - 12 35 .: ,. VR20-3 - 10 .a f 20 _ 6 15 - - 4 10 C 20 40 60 00 10C 1 2,:j 140 160 180 200 Flow (gpm) RECEIVED 10/09/18 ASP6i BUILDING DEPARTMENT OOe VR-15-30-3 ECM High-Efficiency Circulators acll Comfort/So/lions PERFORMANCE or �' (IPm) 0 100 200 300 400 500 600 700 800 900 1000 1100 50 , 1 1 I 1 1 I 1 1 1 1 1 _ 45 - - 14 VR25-3 40 35 - • - 10 25 - i .._. 8.. . - E 2 20 - 6 15 _ - 4 10 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 Flow (gpm) (Ipm) 0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 '-0 1 1 1 1 1 1 1 . 1 1 1 1 1 45 _ ... - 14 VR30-3 40 - 12 35 . . - 10 25 - 8 E 1 20 - 6 15 - 4 10 5 - 2 0 25 50 E. 100 125 150 175 200 225 250 275 300 325 350 Flow (gpm) RECEIVED 10/09/18 36 ASPEN BUILDING DEPARTMENT NOTES: LIMITED WARRANTY STATEMENT Taco,Inc.will repair or replace without charge(at tion of petroleum-based fluids or certain chemical TION OF THE EXPRESS WARRANTY SET the company's option)any product or part which additives to the systems,or other abuse,will not FORTH IN THE FIRST PARAGRAPH ABOVE. is proven defective under normal use within one be covered by this warranty. (1)year from the date of start-up or one(1)year If in doubt as to whether a particular substance is THE ABOVE WARRANTIES ARE IN LIEU OF and six (6) months from date of shipment suitable for use with a Taco product or part,or for ALL OTHER WARRANTIES, EXPRESS OR (whichever occurs first). any application restrictions,consult the applicable STATUTORY, OR ANY OTHER WARRANTY In order to obtain service under this warranty,it is Taco instruction sheets or contact Taco at[401- OBLIGATION ON THE PART OF TACO. the responsibility of the purchaser to promptly no- 942-8000]. TACO WILL NOT BE LIABLE FOR ANY SPE- tify the local Taco stocking distributor or Taco in Taco reserves the right to provide replacement writing and promptly deliver the subject product CIAL, INCIDENTAL, INDIRECT OR CONSE- products and parts which are substantially similar or part,delivery prepaid,to the stocking distribu- in design and functionally equivalent to the defec- tor. For assistance on warranty returns,the pur- tive product or part. Taco reserves the right to USE OF ITS PRODUCTS OR ANY INCIDENTAL chaser may either contact the local Taco stocking make changes in details of design, construction, COSTS OF REMOVING OR REPLACING DE- distributor or Taco. If the subject product or part or arrangement of materials of its products without FECTIVE PRODUCTS. contains no defect as covered in this warranty, notification. the purchaser will be billed for parts and labor This warranty gives the purchaser specific rights, charges in effect at time of factory examination TACO OFFERS THIS WARRANTY IN LIEU OF and the purchaser may have other rights which and repair. ALL OTHER EXPRESS WARRANTIES. ANY vary from state to state.Some states do not allow Any Taco product or part not installed or operated WARRANTY IMPLIED BY LAW INCLUDING limitations on how long an implied warranty lasts in conformity with Taco instructions or which has WARRANTIES OF MERCHANTABILITY OR FIT- or on the exclusion of incidental or consequential been subject to misuse,misapplication,the addi- NESS IS IN EFFECT ONLY FOR THE DURA- damages,so these limitations or exclusions may not apply to you. -is�'i0 COmfort, ir5oIutions.A Taco Family Company Taco,Inc„1160 Cranston Street,Cranston,RI 02920 I Tel:(401)942-8000 I FAX:(401)942-2360 VE Taco(Canada),Ltd.,8450 Lawson Road,Suite#3,Milton,Ontario L9T 0J8 I Tel:(905)564-9422 l FAX:(905)564-9436 Visit our web site:www.TacoComfortcom l Printed in USA I ©2017 Taco,Inc AlirC 10/09/18 ASPEN BUILDING DEPARTMENT 301-3000 ãco Submittal Data Information 00e® Series ComfortSoiutions® VR15-3 VR20-3 VR25-3 VR30-3 ECM Circulators A Taco Family Company 7 7 Effective: August 8, 2017 Supersedes: May 9, 2017 I Job: Engineer: Contractor: Rep: ITEM NO. MODEL NO. Pump Specifications Electrical Specifications Max.Operating Pressure: 1 phase,110-240V,47-63Hz(VR15&VR20) 175 PSI(12 bar) Pump Ratings — 1 phase,230-240V,47-63Hz(VR25&VR30) Water Temperature Range: = VR15 30.027 0.68 HP 36°-230°F(2.2°-110°C) Ambient Operation Temperature Range: VR20-3=0.035-1.088 HP Power Consumption(HP) 32°-104°F(0°-40°C) VR25-3=0.054-1.496 HP Designed for closed loop heating and cooling VR30-3=0.054-2.175 HP systems pumping water or a water/glycol mixture VR15-3=20-500 W Materials of Construction Power Consumption(W) VR20-3=26 800 W VR25-3=46-1100 W Casing Cast Iron VR30-3=40-1550 W Impeller Stainless Steel Shaft Stainless Steel VR15-3=5.6A 2.8A Bearing Metal Impregnated Carbon Rated Current VR20 3=7.2A 3.6A (1 phase,230V) VR25-3=5.3A Standards&Protection VR30-3=7.2A Insulation:Class H VR15-3&VR20-3=6 A Current Limit(Max.) VR25-3&VR30-3 8 A Enclosure:Class 2,IP44 = Integrated Motor Protection(electronically protected) Max.Current up to 100 mA,Output Voltage Continuous Duty 24V Supply Output of 24V 20%,Output Ripple under 1V UL 778,1004-1,508C oeOos CAN/CSA C22.2#108,#100,#107.1 8A,Max.Voltage 250 VAC,48 VDC EMC(89/366 EEC):EN 61000 4004896 Relay Output: Max.Load up to 500 VA LVD(73/23/EC):EN 60335-1,EN 60335-2-51 Machine Safety(98/37/EC):EN ISO 12100 Max.Input Voltage=32VDC Digital Inputs: 2 Inputs&1 Output Operating Modes Logical»1«Voltage>8V,Logical»0«Voltage<2V Constant Pressure Control(Op-c) Connector=RJ-45 Variable Differential Pressure Control Ethernet: — (Ap-v)-factory default Services=hap server and client,FTP server Proportional Pressure Control o B Minimum static inlet pressure at Constant Curve Duty(uncontrolled pump) 1 pump suction port(PSI/bar)to avoid RPM Regulation rir cavitation at fluid temperatures Power Limitation(amps or watts) °°' Fluid VR15&VR20 VR25&VR30 n Temperatures (PSI/bar) (PSI/bar) Control Modes 112°F(50°C) 7.3/0.5 4.35/0.3 0 10Vdcin 176°F(80°C) 11.6/0.8 14.5/1.0 ModBus RTU RIF E = 230°F(110°C) 20.3/1.4 23.2/1.6 Model Flange Size Power A B C D E F Weight Number (ANSI) (HP) in. mm in. mm in. mm in. mm in. mm in. mm lbs. Kg VR15-3 1-1/2" 0.027-0.680 9-13/16 250 15-3/16 386 12-5/8 321 7-13/16 198 7-7/16 189 10-1/16 255 57 26 VR20-3 2" 0.035-1.088 11 280 16-3/4 425 13-1/4 336 7-15/16 201 7-7/16 189 10-1/16 255 71 32 VR25-3 2-1/2" 0.054-1.496 13-3/8 340 17-11/16 449 14-1/2 369 8-11/16 221 7-7/16 189 10-1/16 255 82 37 VR30-3 3" 0.054-2.175 14-3/16 360 19-13/16 503 15-7/8 403 9-1/4 235 7-7/16 189 10-1/16 255 99 45 :_arovED NFamily CO Comfort/Solutions ATaco Company Taco,Inc.,1160 Cranston Street,Cranston,RI 02920 I Tel:(401)942-8000 I FAX:(401)942-2360 v /18 Taco(Canada),Ltd.,8450 Lawson Road,Suite#3,Milton,Ontario L9T 0J8 I Tel:(905)564-9422 I FAX:(905)564-9436 Visit our web site:www.TacoComfort.com I Printed in USA I 522017 Taco,Inc. ASPEN BUILDING DEPARTMENT