HomeMy WebLinkAboutFile Documents.210 S 1st St.0281.2017 (16).ARBK AIR CONDITIONERS XC16 I EIVIt1OX ELITE® Series R-410A - Two-Stage Compressor PRODUCT SPECIFICATIONS Bulletin No.210465 September 2014 Supersedes August 2014 ter` e 000\�00 � LEN104W aa��� 0 � o --am— �_ '\ 7.:.—!!!! e! errn ,,,, _____. 1""7717! _CU-1 = XC16-024 ENERGY STAR _CU-2 = XC16-024 CU-3 = XC16-048 SEER up to 17.00 2to5Tons ALL UNITS Cooling Capacity - 23,000 to 57,500 Btuh MODEL NUMBER INDENTIFICATION X C16 - 036 - 230 - 5 Refrigerant Type T T _I Minor Revision Number X=R-410A Unit Type Voltage C=Air Conditioned 230=208/230V-1 phase-60hz Series Nominal Cooling Capacity 024=2 tons 0 =3tons RECEIVED 04848=4 tons RECEIVED 060=5 tons 10/09/18 ASPEN BUILDING DEPARTMENT FEATURES REFRIGERATION SYSTEM (continued) COMPRESSOR 0 Copper Tube/Enhanced Fin Coil 0 Copeland Scroll Ultra TechTM Two-Stage Compressor Lennox designed and fabricated coil. Compressor features temperature flnsting seal Ripple-edged aluminum fins. high efficiency with operated disc C. I Copper tube construction. uniform suction flow, ' tf�°J Discharge constant discharge Internal I II `hre`°aM' Lanced finsprovide maximum exposure of fin surface to a °°° .r p flow, high volumetric .awe I air stream resultingin excellent heat transfer. .. 1 Scroll set efficiency and quiet Shutdown Fin collars grip tubing for maximum contact area. operation. </ewe ' J Motor pro- Flared shoulder tubing connections/silver soldering Compressor consists tenter construction. of two involute spiral °pbea rg/ scrolls matched system 'F`-- . High-efficiency Coil is factory tested under high pressure to insure leakproof construction. together to generate POE lubricant a series of crescent (optional) Entire coil is accessible for cleaning. shaped gas pockets ' High Pressure Switch between them. r _ Shuts off unit if abnormal operating conditions cause the During compression, discharge pressure to rise above setting. one scroll remains Protects compressor from excessive condensing stationary while the pressure. other scroll orbits around it. Auto-reset. Gas is drawn into the outer pocket, the pocket is sealed as the scroll rotates. 0 Low Pressure Switch As the spiral movement continues, gas pockets are Shuts off unit if suction pressure falls below setting. pushed to the center of the scrolls. Volume between the Provides loss of charge and freeze-up protection. pockets is simultaneously reduced. Auto-reset. When the pocket reaches the center, gas is now at 0 Hi-Capacity Liquid Line Drier high pressure and is forced out of a port located in the Factory installed in the liquid line, the drier traps center of the fixed scrolls. During compression, several moisture or dirt that could contaminate the refrigerant pockets are compressed simultaneously resulting in a system. smooth continuous compression cycle. 100% molecular-sieve bead type drier. Continuous flank contact, maintained by centrifugal force, minimizes gas leakage and maximizes efficiency. Optional Accessories Scroll compressor is tolerant to the effects of slugging Expansion Valve Kits and contaminants. If this occurs, scrolls separate, Must be ordered extra and field installed on certain allowing liquid or contaminants to to be worked toward indoor units. See TXV Usage table. the center and discharged. Chatleff style fitting. During the compression process, there are several pockets in the scroll that are compressing gas. Freezestat Modulation is achieved by venting a portion of the gas Installs on or near the discharge line of the indoor coil or in the first suction pocket back to the low side of the on the suction line. compressor thereby reducing the effective displacement Senses suction line temperature and cycles the of the compressor. compressor off when suction line temperature falls A 24-volt DC solenoid valve inside the compressor below it's setpoint. "°a;;Oor , "7,r,,,' controls staging. When the 3-way Opens at 29°F and closes at 58°F. j'r oar_ solenoid is energized it moves the �� lift ring assembly to block the Refrigerant Line Kits1111:p • ports and the compressor Refrigerant lines (suction & liquid)are shipped 4 ,L, operates at full-load or 100% refrigeration clean. Lines are cleaned, dried, capacity. When the solenoid is pressurized, and sealed at factory. 1 - de-energized the lift ring assembly Suction line fully insulated. moves to unblock the compressor L15 lines are stubbed at both ends. ports and the compressor operates at part-load or approximately 67% of its full-load capacity. See Specifications table for selection. The "loading" and "unloading" of the , . st§l' -,4•' I Not available for-060 model and must be field done "on the fly"without shutting off °-Nsiriiglb'-p � fabricated. compressor motor between stages. Low gas pulses during compression reduces/0 9/18 operational sound levels. c XC16-2 to 5 Ton AMMO! T FEATURES COMPRESSOR (continued) Indoor Blower Speed Relay Compressor motor is internally protected from Relay kit provides optimum humidity control conditions excessive current and temperature. by automatically reducing indoor blower speed during Compressor is installed in the unit on specially continuous fan or first-stage compressor operation. formulated, resilient rubber mounts for better sound Low Ambient Kit dampening and vibration free operation. Air conditioner will operate satisfactorily down to 45°F Crankcase Heater(048-060 models only) outdoor air temperature without any additional controls. Crankcase heater prevents migration of liquid Kit can be added in the field enabling unit to operate refrigerant into compressor and ensures proper properly down to 30°F. compressor lubrication. A Freezestat and optional Crankcase Heater(024-036) should be installed on compressors equipped with a low Optional Accessories ambient kit. Crankcase Heater(Optional for 024-036 models) A Compressor Low Ambient Cut-Off should be added to Crankcase heater prevents migration of liquid terminate compressor operation below recommended refrigerant into compressor and ensures proper operation conditions. compressor lubrication. Thermostat Compressor Hard Start Kit Thermostat not furnished with unit. See Thermostat Single-phase units are equipped with a PSC bulletins in Controls Section and Lennox Price Book. compressor motor. This type of motor normally does not CABINET need a potential relay and start capacitor. 0 Heavy-gauge steel construction In conditions such as low voltage, kit may be required to Pre-painted cabinet finish. increase the compressor starting torque. Control box is conveniently located with all controls Hard start kit is required in applications where the factory wired. supply voltage is less than 230V. Large removable panel provides service access. Drainage holes are provided in base section for CONTROLS moisture removal. Optional Accessories High density polyethylene unit support feet raise the unit off of the mounting surface, away from damaging Blower Relay Kit moisture. (For Use With EL195E and ML180E Gas Furnaces) Allows furnace blower speed changes when matched PermaGuardTM Unit Base with two-stage air conditioners. Durable zinc-coated base section resists rust and corrosion. ComfortSense®7000 Touchscreen Thermostat Electronic 7-day, universal, 0 SmartHinge- Louvered Coil Protection multi-stage, programmable, Steel louvered panels touchscreen thermostat. provides complete coil 4 Heat/2 Cool. E.o ,,,,of o protection. "" O Auto-changeover. Panels are hinged to allow ��• °� � ' Controls humidity during o,A„ easy cleaning and servicing cooling mode. of coils. - Offers enhanced capabilities Panels may be completely including humidification/ removed. , dehumidification /dewpoint measurement and control, Interlocking tabs and slots Humiditrol®control, and equipment maintenance assure tight fit on cabinet. reminders. 0 Refrigerant Line Connections, Electrical Inlets and Easy-to-use, menu driven thermostat with a back-lit, Service Valves LCD touchscreen. Suction and liquid lines are located on corner of unit Remote outdoor temperature sensor(optional) allows cabinet and are made with sweat connections. See the thermostat to display outdoor temperature. Required dimension drawing. in dual fuel and Humiditrol®applications. Fully serviceable brass service valves prevent corrosion See the ComfortSense 7000 Product Specifications and provide access to refrigerant system. Suctio valve bulletin in the Controls section for more information. can be fully shut off, while liquid valve ma .; .-.n EIVED Indoor Blower Off Delay Relay seated to manage refrigerant charge while >' ifib Delays the indoor blower-off time during the cooling system. 10/0 9/18 cycle. Refrigerant line connections and field wiring inlets are located in one central area of the cabinet. See ASPEN XC16-2 to 5 Ton Air Conditioner /Page 4 dimension drawing. BUILDING DEPARTMENT SPECIFICATIONS General Model No. XC16-024 XC16-036 XC16-048 XC16-060 Data Nominal Tonnage 2 3 4 5 Connections Liquid line (o.d.)-in. 3/8 3/8 3/8 3/8 (sweat) Suction line (o.d.)-in. 3/4 7/8 7/8 — 1-1/8 Refrigerant 1 R-410A charge furnished 7 lbs. 5 oz. 8 lbs. 6 oz. 10 lbs. 7 oz. 12 lbs. 1 oz. Outdoor Net face area-sq.ft. Outer coil 24.50 16.33 21.00 29.09 Coil Inner coil --- 15.76 20.27 28.24 Tube diameter-in. 5/16 5/16 5/16 5/16 No. of rows 1 2 2 2 Fins per inch 26 22 22 22 Outdoor Diameter-in. 22 22 22 26 Fan No. of blades 4 4 4 3 Motor hp 1/6 1/4 — 1/3 — 1/3 Cfm- 1st stage 3260 3500 3190 4325 2nd stage --- --- 3700 --- Rpm- 1st stage 840 825 705 865 2nd stage --- --- 820 --- Watts- 1st stage 220 300 165 240 2nd stage --- --- 260 --- Shipping Data-lbs. 1 pkg. 249 243 268 332 ELECTRICAL DATA Line voltage data-60hz 4 230V-1 ph 4 230V-1 ph L 4 230V-1 ph I 4 230V-1 ph 2 Maximum overcurrent protection (amps) 25 35 50 60 3 Minimum circuit ampacity 15.7 20.8 29.2 35.6 Compressor Rated load amps 11.66 15.25 21.15 27.1 Locked rotor amps 58.3 83 104 152.9 Power factor 0.98 0.99 0.99 0.99 Outdoor Fan Full load amps 1.0 1.7 2.8 1.8 Motor Locked Rotor amps 1.9 3.1 N/A 2.9 OPTIONAL ACCESSORIES - ORDER SEPARATELY Blower Relay Kit 85W66 • (for EL195E and ML180E gas furnaces) ComfortSense®7000 Thermostat Y2081 • Outdoor Temperature Sensor-for X2658 • • ComfortSense 7000 Thermostat Compressor Crankcase Heater 93M04 • • Factory Compressor Hard Start Kit-Required in 63W22 • applications with less than 230V 10J42 • 63W24 • Compressor Low Ambient Cut-Off 45F08 • • Compressor Time-Off Control 47J27 • • Freezestat 3/8 in.tubing 93G35 • 5/8 in. tubing 50A93 • Indoor Blower Off Delay Relay 58M81 • Indoor Blower Speed Relay 40K58 • 5 Low Ambient Kit 34M72 • 68M04 • Refrigerant L15-41-20 L15-41-40 • Line Sets L15-41-30 L15-41-50 L15-65-30 L15-65-40 • L15-65-50 Field Fabricate • NOTE-Extremes of operating range are plus 10%and minus 5%of linetioltagc. Refrigerant charge sufficient for 15 ft.length of refrigerant lines.For longer line set requirements see the Installation Instructions for information about line set len th and additional refrigerant charge required. REc E f�I'E C� 2 HACR type breaker or fuse. 3 Refer to National or Canadian Electrical Code manual to determine wire,fuse and disconnect size requirements. 4 Hard Start Kit is required in applications where the supply voltage is less than 230V. 1 0/0 9/1 8 5 Crankcase Heater(if not furnished)and Freezestat are recommended with Low Ambient Kit. C XC16-2 to 5 Ton Aiglrgitf ? NT SPECIFICATIONS General Model No. XC16-024 XC16-036 XC16-048 XC16-060 Data Nominal Tonnage 2 3 4 5 Connections Liquid line (o.d.)-in. 3/8 3/8 3/8 3/8 (sweat) Suction line (o.d.)-in. 3/4 7/8 7/8 — 1-1/8 Refrigerant 1 R-410A charge furnished 7 lbs. 5 oz. 8 lbs. 6 oz. 10 lbs. 7 oz. 12 lbs. 1 oz. Outdoor Net face area-sq.ft. Outer coil 24.50 16.33 21.00 29.09 Coil Inner coil --- 15.76 20.27 28.24 Tube diameter-in. 5/16 5/16 5/16 5/16 No. of rows 1 2 2 2 Fins per inch 26 22 22 22 Outdoor Diameter-in. 22 22 22 26 Fan No. of blades 4 4 4 3 Motor hp 1/6 1/4 — 1/3 — 1/3 Cfm- 1st stage 3260 3500 3190 4325 2nd stage --- --- 3700 --- Rpm- 1st stage 840 825 705 865 2nd stage --- --- 820 --- Watts- 1st stage 220 300 165 240 2nd stage --- --- 260 --- Shipping Data-lbs. 1 pkg. 249 243 268 332 ELECTRICAL DATA Line voltage data-60hz 4 230V-1 ph 4 230V-1 ph L 4 230V-1 ph I 4 230V-1 ph 2 Maximum overcurrent protection (amps) 25 35 50 60 3 Minimum circuit ampacity 15.7 20.8 29.2 35.6 Compressor Rated load amps 11.66 15.25 21.15 27.1 Locked rotor amps 58.3 83 104 152.9 Power factor 0.98 0.99 0.99 0.99 Outdoor Fan Full load amps 1.0 1.7 2.8 1.8 Motor Locked Rotor amps 1.9 3.1 N/A 2.9 OPTIONAL ACCESSORIES - ORDER SEPARATELY Blower Relay Kit 85W66 • (for EL195E and ML180E gas furnaces) ComfortSense®7000 Thermostat Y2081 • Outdoor Temperature Sensor-for X2658 • • ComfortSense 7000 Thermostat Compressor Crankcase Heater 93M04 • • Factory Compressor Hard Start Kit-Required in 63W22 • applications with less than 230V 10J42 • 63W24 • Compressor Low Ambient Cut-Off 45F08 • • Compressor Time-Off Control 47J27 • • Freezestat 3/8 in.tubing 93G35 • 5/8 in. tubing 50A93 • Indoor Blower Off Delay Relay 58M81 • Indoor Blower Speed Relay 40K58 • 5 Low Ambient Kit 34M72 • 68M04 • Refrigerant L15-41-20 L15-41-40 • Line Sets L15-41-30 L15-41-50 L15-65-30 L15-65-40 • L15-65-50 Field Fabricate • NOTE-Extremes of operating range are plus 10%and minus 5%of linetioltagc. Refrigerant charge sufficient for 15 ft.length of refrigerant lines.For longer line set requirements see the Installation Instructions for information about line set len th and additional refrigerant charge required. REc E f�I'E C� 2 HACR type breaker or fuse. 3 Refer to National or Canadian Electrical Code manual to determine wire,fuse and disconnect size requirements. 4 Hard Start Kit is required in applications where the supply voltage is less than 230V. 1 0/0 9/1 8 5 Crankcase Heater(if not furnished)and Freezestat are recommended with Low Ambient Kit. C XC16-2 to 5 Ton Aigitrbiit ? NT SPECIFICATIONS General Model No. XC16-024 XC16-036 XC16-048 XC16-060 Data Nominal Tonnage 2 3 4 5 Connections Liquid line (o.d.)-in. 3/8 3/8 3/8 3/8 (sweat) Suction line (o.d.)-in. 3/4 7/8 7/8 — 1-1/8 Refrigerant 1 R-410A charge furnished 7 lbs. 5 oz. 8 lbs. 6 oz. 10 lbs. 7 oz. 12 lbs. 1 oz. Outdoor Net face area-sq.ft. Outer coil 24.50 16.33 21.00 29.09 Coil Inner coil --- 15.76 20.27 28.24 Tube diameter-in. 5/16 5/16 5/16 5/16 No. of rows 1 2 2 2 Fins per inch 26 22 22 22 Outdoor Diameter-in. 22 22 22 26 Fan No. of blades 4 4 4 3 Motor hp 1/6 1/4 — 1/3 — 1/3 Cfm- 1st stage 3260 3500 3190 4325 2nd stage --- --- 3700 --- Rpm- 1st stage 840 825 705 865 2nd stage --- --- 820 --- Watts- 1st stage 220 300 165 240 2nd stage --- --- 260 --- Shipping Data-lbs. 1 pkg. 249 243 268 332 ELECTRICAL DATA Line voltage data-60hz 4 230V-1 ph 4 230V-1 ph L 4 230V-1 ph I 4 230V-1 ph 2 Maximum overcurrent protection (amps) 25 35 50 60 3 Minimum circuit ampacity 15.7 20.8 29.2 35.6 Compressor Rated load amps 11.66 15.25 21.15 27.1 Locked rotor amps 58.3 83 104 152.9 Power factor 0.98 0.99 0.99 0.99 Outdoor Fan Full load amps 1.0 1.7 2.8 1.8 Motor Locked Rotor amps 1.9 3.1 N/A 2.9 OPTIONAL ACCESSORIES - ORDER SEPARATELY Blower Relay Kit 85W66 • (for EL195E and ML180E gas furnaces) ComfortSense®7000 Thermostat Y2081 • Outdoor Temperature Sensor-for X2658 • • ComfortSense 7000 Thermostat Compressor Crankcase Heater 93M04 • • Factory Compressor Hard Start Kit-Required in 63W22 • applications with less than 230V 10J42 • 63W24 • Compressor Low Ambient Cut-Off 45F08 • • Compressor Time-Off Control 47J27 • • Freezestat 3/8 in.tubing 93G35 • 5/8 in. tubing 50A93 • Indoor Blower Off Delay Relay 58M81 • Indoor Blower Speed Relay 40K58 • 5 Low Ambient Kit 34M72 • 68M04 • Refrigerant L15-41-20 L15-41-40 • Line Sets L15-41-30 L15-41-50 L15-65-30 L15-65-40 • L15-65-50 Field Fabricate • NOTE-Extremes of operating range are plus 10%and minus 5%of linetioltagc. Refrigerant charge sufficient for 15 ft.length of refrigerant lines.For longer line set requirements see the Installation Instructions for information about line set len th and additional refrigerant charge required. REc E f�I'E C� 2 HACR type breaker or fuse. 3 Refer to National or Canadian Electrical Code manual to determine wire,fuse and disconnect size requirements. 4 Hard Start Kit is required in applications where the supply voltage is less than 230V. 1 0/0 9/1 8 5 Crankcase Heater(if not furnished)and Freezestat are recommended with Low Ambient Kit. C XC16-2 to 5 Ton Aigitrbiit ? NT SPECIFICATIONS General Model No. XC16-024 XC16-036 XC16-048 XC16-060 Data Nominal Tonnage 2 3 4 5 Connections Liquid line (o.d.)-in. 3/8 3/8 3/8 3/8 (sweat) Suction line (o.d.)-in. 3/4 7/8 7/8 — 1-1/8 Refrigerant 1 R-410A charge furnished 7 lbs. 5 oz. 8 lbs. 6 oz. 10 lbs. 7 oz. 12 lbs. 1 oz. Outdoor Net face area-sq.ft. Outer coil 24.50 16.33 21.00 29.09 Coil Inner coil --- 15.76 20.27 28.24 Tube diameter-in. 5/16 5/16 5/16 5/16 No. of rows 1 2 2 2 Fins per inch 26 22 22 22 Outdoor Diameter-in. 22 22 22 26 Fan No. of blades 4 4 4 3 Motor hp 1/6 1/4 — 1/3 — 1/3 Cfm- 1st stage 3260 3500 3190 4325 2nd stage --- --- 3700 --- Rpm- 1st stage 840 825 705 865 2nd stage --- --- 820 --- Watts- 1st stage 220 300 165 240 2nd stage --- --- 260 --- Shipping Data-lbs. 1 pkg. 249 243 268 332 ELECTRICAL DATA Line voltage data-60hz 4 230V-1 ph 4 230V-1 ph L 4 230V-1 ph I 4 230V-1 ph 2 Maximum overcurrent protection (amps) 25 35 50 60 3 Minimum circuit ampacity 15.7 20.8 29.2 35.6 Compressor Rated load amps 11.66 15.25 21.15 27.1 Locked rotor amps 58.3 83 104 152.9 Power factor 0.98 0.99 0.99 0.99 Outdoor Fan Full load amps 1.0 1.7 2.8 1.8 Motor Locked Rotor amps 1.9 3.1 N/A 2.9 OPTIONAL ACCESSORIES - ORDER SEPARATELY Blower Relay Kit 85W66 • (for EL195E and ML180E gas furnaces) ComfortSense®7000 Thermostat Y2081 • Outdoor Temperature Sensor-for X2658 • • ComfortSense 7000 Thermostat Compressor Crankcase Heater 93M04 • • Factory Compressor Hard Start Kit-Required in 63W22 • applications with less than 230V 10J42 • 63W24 • Compressor Low Ambient Cut-Off 45F08 • • Compressor Time-Off Control 47J27 • • Freezestat 3/8 in.tubing 93G35 • 5/8 in. tubing 50A93 • Indoor Blower Off Delay Relay 58M81 • Indoor Blower Speed Relay 40K58 • 5 Low Ambient Kit 34M72 • 68M04 • Refrigerant L15-41-20 L15-41-40 • Line Sets L15-41-30 L15-41-50 L15-65-30 L15-65-40 • L15-65-50 Field Fabricate • NOTE-Extremes of operating range are plus 10%and minus 5%of linetioltagc. Refrigerant charge sufficient for 15 ft.length of refrigerant lines.For longer line set requirements see the Installation Instructions for information about line set len th and additional refrigerant charge required. REc E f�I'E C� 2 HACR type breaker or fuse. 3 Refer to National or Canadian Electrical Code manual to determine wire,fuse and disconnect size requirements. 4 Hard Start Kit is required in applications where the supply voltage is less than 230V. 1 0/0 9/1 8 5 Crankcase Heater(if not furnished)and Freezestat are recommended with Low Ambient Kit. C XC16-2 to 5 Ton Aigitrbiit ? NT