HomeMy WebLinkAboutFile Documents.743 Cemetery Ln.0011.2018 (23).ARBK • ••••
**** •
fa ntech
•.•
Ventilation Solutions
Laundries
door
a. EASYCARE •
`yi9/yf'lffi9ff
PHA MSS
� , TIMED DRY
2 1 Laundries
A New Day - and a New Name
for Dryer Exhaust Fans
Remember the good old days when laundry spaces were proximity to bedrooms, multi-function capability, elaborate
designed so that clothes dryers could be vented directly storage and fixtures, etc.) many homeowners are putting
through an exterior wall with just a few feet of straight builders and contractors in a tough spot when it comes
duct? Those days are over. Seduced by the fashion and to proper and effective dryer ventilation.
functionality of the latest laundry room trends (including
r ,
N0 . In! ps
7
_________
I
( C ( C 1(( LCD
�� Indicator panel
L''')
.__ _ ‘ I iii 1...., *,. ,______,..,,,,_,.,,,..,,
lifci'. ' , ,
.1,.. ,
J
...
y'\
LE
p� IIII Illp,
nu�1"::.„n
/ 11, r��ii��r��rr��l�
11.11 yjlieji 1iumir/
$1 1110, OPIl1si I11m,i
1 ,11 11 //1/°1
'11j 1_/ 001/�1
Iv, ,.`::: IN ill . L., '� CEIVED
09/21/2018
s'' fantech
ASPEN
BUILDING DEPARTMENT
Laundries 1 3
G
Dryer Exhaust Duct Power
• Ventilator
BF - -
Such preferences often result in longer duct runs with multiple bends and
turns that impair dryer efficiency and interfere with a builder's ability to
meet building code.A properly applied dryer exhaust fan,preferably one that
meets the latest UL Standard,may be the only solution that makes everyone
happy—including the home inspector and the local fire chief.
• The 2012 International Residential Code(IRC)is pretty specific when it
comes to dryer exhaust venting.The maximum length for dryer exhaust duct
B cannot exceed 35 feet from the dryer location to the wall or roof termination.
Each elbow reduces this maximum allowable length by 5 feet since the
restricted airflow that these fittings create is more than the same length of
linear duct.Each dryer exhaust has its own specifications for duct length,
® so contractors should refer to these instructions,as well,to make sure the
o dryer duct length does not exceed a particular model's capability.Given
® o 0these restrictions,it is highly likely that dryers located in interior spaces will
o _� exceed either the IRC or the manufacturer's limits on duct length.
For years,these fans have been applied with great success in homes with
excessively long dryer exhaust duct runs.And many homeowners,once
burdened with long dryer cycles and perpetually damp clothes,have been
delighted with the results.
MIMEr
Underwriters Laboratory(UL)has since
developed a supplement to UL705 that
U does specifically address the safety of fans
L
used to facilitate proper dryer exhaust and
® . ,
hasgiven theproduct a new ranhe;Dr
,____,_,
Exhaust Duct Power Ventilator(DEDPV).' E ,,,-,,,,,
'-
09/21/' 018
CiktftWI
BUILDING DEPARTMENT
4 Work
MORE THAN
JUST A DRYER
EXHAUST FAN . .
I •t
The DBF4XLT-705 (DEDPV) allows for _� •-
4" dryer exhaust duct runs up 130 feet and
meets the new UL requirements.
All fans are equipped with an upgraded
pressure sensing circuit, LED indicator display panel,
temperature limit switch, and fast clamps for easy
installation and maintenance.
:r fantech
Work 1 5
IT ' S A uL
LISTED DEDPV
77
1
:,44 ' 4111
, 0 k Ntof
,
ki, 11,
r 1
1 1 III I r,
‘1. ,
., ,...:...
I •
,
1
Pt I
I
*At
-.wit N
4 O.
.a.. _
-
I
I Ili ill II III 1 I .b..
Nii:1113v
h.. u..
:r. fa ntech
6 Laundries
Distinguishing features between DEDPVs
and other dryer exhaust fans
While fans of another name maybe installed in dryer exhaust applications(at least for now)UL has
announced that all Dryer Exhaust Duct power Ventilators"DEDPV"products manufactured after July 31,
2012 must comply with the new supplemented requirements of UL705 for sale in the US market.
The new UL testing standards for DEDPV products are quite complex and have been adjusted to pertain
exclusively to the operation of ventilation fans in dryer applications.The tests confirm key safety
features and operation,including redundant safety circuits,adequate air velocities,temperature sensing
mechanisms,cleanout access,etc.These tests go well beyond the UL standards that
were once imposed on dryer exhaust fans.And while they may not be required by
building codes yet,eventually most if not all jurisdictions will require the UL marking
for fans used in this application.
The primary differences between DEDPVs
and other dryer exhaust fans are:
DEDPV fan housings are always made of metal, In the event of a fire in the dryer or exhaust duct, Under normal operating conditions,the LED
never plastic. the fan senses the rise in temperature and shuts panel of a DEDPV,which should be prominently
down within 15 seconds,limiting the spread of displayed in a laundry room,will illuminate
fire and damage to the home.The therminal box is when the fan is in operation.This steady state
equipped with an integrated pressure switch. illumination should correspond with the operation
of the dryer for the duration of the cycle.
fantech
1110.
of
f .�mode=Z
Fr
�Mud`.
RECEIVED
09/21/2018
':fantech
ASPEN
BUILDING DEPARTMENT
Laundries 1 7
D B F 4XLT-705 [61:
Dryer Exhaust Duct Power Ventilator 0
• UL Listed to UL705 supplement
CD IMO
• Indicator panel is included
• Temperature limit switch,shuts down the fan in case of fire
• Metal housing
• Integrated pressure switch
• Maintains 1,200FPM velocity:lint doesn't drop into the duct
The Fantech dryer exhaust duct power ventilator has been specially designed to
solve the problems caused by long duct runs on clothes dryers.
When the dryer is on,Fantech's patented pressure sensing switch automatically
turns the ventilator on.The warm,moist air in the dryer duct is exhausted out • r • 1,
of the building quickly.The DEDPV monitors the status of the dryer and will turn
itself off when the dryer stops.Wall mounted indicator panel with LED display
lets homeowners know that fan is fully operational.The panel will also alert 4111•.,. NO
homeowners of problems such as no power,blocked duct,locked motor rotor
and low speed conditions. a. _
The system includes 2 pair of mounting clamps with a pair of cleanouts and a
wall mount low voltage LED indicator panel.A 50 foot control cable is included
to connect the indicator panel to the DEDPV.The unit can be used to effectively
exhaust a 4 inch dryer duct run up to 130 feet.
Specification data
Duct Rated Voltage/ Max. 0.0"Ps 0.2"Ps 10.4"P. 0.6"Ps 0.8"Ps 1.0"Ps Shipping UPC#
Model size power phase amps weight
inch W V/— A cfm lbs
DBF 4XLT-705 4 83 120/1 0.73 170 150 134 119 103 86 10 46005 1
Per HVOS Certified rating program,charted air flow performance has been derated by a factor based on actual test results and the certified rate at 0.2 inches WG.
Dimensions
1
Cleaning the dryer exhaust is
now easier and quicker.
■ ii
ii_ 615'16 The DEDPV is designed with
378 access points before and after
I the fan,which allows for easy
-.41-11.- access to the duct and fan
2 1. .1 1 . impeller.
378 RECEIVED
Dimensional information is in inches.
09/21/2018
CAtftWi
BUILDING DEPARTMENT
s 1 Laundries
DBF Series [et
Dryer Exhaust Fans SA®
DBF4XL-DBF4XLT DBF4XLT
• Airtight galvanized steel housing ensures no leakage into structure
• Maintains 1,200 FPM velocity to suspend lint
• Pressure switch to activate the fan when the dryer is on _
• 51/2 feet electrical cord with plug and mounting bracket �'�
DBF 4XL and DBF 4XLT are dryer exhaust fans with backward inclined blades ilk
of the motorized impeller,which allows lint to pass through the fan.These �.�� -.....-
-_—
models can be used to effectively exctract dryer exhaust in duct runs up to DBF 4XL
130 feet. - -
The DBF 4XLT model features an integrated airflow sensing switch,quick
connect/disconnect fast clamp,and wall-mount indicator panel.LED light on
the panel lets homeowners know fan is working properly. DBF 110 it
/Le 1, _ l'i--
DBF 110 4�
• Maintains 1,200 FPM velocity to suspend lint
The DBF 110 dryer exhaust fan is engineered of thermoplastic resin and
features an integrated automatic pressure switch.It can be used on dryer
duct runs up to 108 feet.The fan's backward inclined blades allow lint to pass
through the fan.The fan can be mounted in any angle at any point along the
duct run and its straight-through air flow design allows for easy installation.
Specification data
Duct Rated Voltage/ Max. 0.0"0, 0.2"0, 0.4"P, 0.6"P, 0.8"P, 1.0"P, Shipping UPC#
Model size power phase amps weight
inch W V/- A lbs
DBF4XLT 4 83 120/1 0.73 170 150 134 119 103 86 10 12540 0
DBF4XL 4 ja 83m1. , 10 12040
DBF110 4 80 120/1 0.72 167 150 133 113 88 63 9 12110 5
Per HVI'S Certified rating program,charted air flow performance has been derated by a factor based on actual test results and the certified rate at 0.2 inches WG.
Dimensions
DBF4XLT 1: DBF4XL I i DBF 110 1,37b8H
o
All&J
3 615,1s 37 l
615/16 111/4„
v Mk II
2 II—.11- 2 1 -0-11—1
37e 37$ I\ED
<< 91/2' AP
121/2"
Dimensional information is in inches.
09/21/2018
':fantech
ASPEN
BUILDING DEPARTMENT
Laundries 1 9
RVF 4XL . 1p-
aumma
Exterior-Mount Fan for Dryer ExhaustingMk
RVF 4XL
• Galvanized steel housing features powder-coat finish
• External rotor motor with totally enclosed design allows fans to operate in
high moisture,lint and dust laden air
• Motors feature thermal reset overload protection `\
• All motors and impellers are designed as one integral unit,allowing for
excellent motor heat dissipation,even at low RPM
• Permanently lubricated sealed ball bearing for long life and maintenance . ��
free operation
Fantech's popular exterior-mount exhaust fan with white,powdercoated metal
housing can be used for dryer exhausting when paired with a DB10 Pressure
Switch(purchase separately).Ideal for condos and apartments as well as
homes.Effective on duct runs up to 130 feet.Pressure switch automatically
activates the fan when the dryer comes on.
Specification data
Duct Rated Voltage/ Max. 10.0"P 10.2"P 10.4"P 0.6"Ps 0.8"Ps 1.0"Ps Shipping UPC#
Model size power phase amps weight
inch W V/— A I cfm Ibs
RVF 4XL 4 92 120/1 0.84 193 172 154 136 118 91 10 23045 6
Performance shown is for installation type with duct inlet Per HVI'S Certified rating program,charted air flow performance has been derated by a factor based on actual test results and the certified rate
at 0.2 inches WG.RVF Series performance is shown with ducted inlet.
r E—
Dimensions
Model At IB IC ID IE
RVF 4XL 3 7/8 101/4 13 6 2 3/4
Dimensional information is in inches.
1 ■'
A Air flow
==REEIVED
D B 09 21/2018
.'c°.Atft N
BUILDING DEPARTMENT
�o Laundries
Accessories
for Dryer Exhaust Fans
DBLT 4W DB 10
Lint Trap for Dryer Exhaust Fans Pressure Switch
Galvanized metal lint trap for dryer exhausting - Automatic pressure switch allows for
applications.Use when duct length between fully automatic operation of dryer exhaust
dryer and exhaust fan is less than 15 feet.Fits fan.Fan runs for 10 minutes when positive .41
4-inch duct and 2"x6"constructions.Features _ pressure is sensed in the duct line then
pull out white door with a view window with shuts off and turns on again as needed.
attached removable lint filter for easy cleaning and 1/2"flange for flush The switch is used with DBF 4XL,DBF 110 1
mount installation.The lint trap complements all Fantech dryer exhaust fans. and RVF 4XL.
Specification Data Specification Data
Model Duct Size, Accessability Weight, UPC# Model Voltage, Max Current,A Weight, UPC#
inch lbs V lbs
DBLT4W 4 Door 4 12004 7 DB10 115 2 1 12010 2
Fast Clamps
Our Fast Clamps facilitate the installation and i \
removal of fans for service and cleaning.Made
from galvanized sheet steel and fitted with an
1/3„neoprene lining,which suppresses vibration
and ensures a tight fit.The mounting clamps are
fastened together by two screws,which allow for
connecting ducts with a marginal difference in diameter.Sold in pairs.
Specification Data
Model oD Neoprene Weight, UPC--
lining,inch lbs
FC 4 4 1/3 1 51040 4
FC 5 5 1/3 1 1111 51050
Dimensions 1/3
(2x) —\ ,.
3
Dimensional information is in inches.
°° 21/s" RECEIVED
09/21/2018
fantech
ASPEN
BUILDING DEPARTMENT
•
___ 4
7__. _ _ __ _ .,-_ . LatigEk,ii---k---11
- - ,_ -tom L --
D I I I -- - f
1 i ,' i
That according to the National Fire
Prevention Association (NFPA), the
fIII =��, ' _ _ leading cause of home fires is from
- ; 9 dryerY_, lint i nition in the or dry er
duct?
/
A DEDPV or Dryer Booster from Fantech maintains
an airflow that keeps lint suspended exhausting it
— to the outside,thereby reducing the risk of fire.
Sntu Com
Dryer Exhaust Duct = _ That can occur inaneo the dryers afterbustion th
Power Ventilator dryer stopspo due to high heat and no
DBF 4XLT-705 _ I.,. - - airflow?
The DEDPV continues to operate for a short
low jihir
period of time after the dryer stops which ..'
cools the clothes and lessens the risk of
spontaneous combustion.
Dryers don't have an indicator to
11 a r ' . • tell if there is a build up of lint in the
(/ ' duct?
( , l ,r
�, . �, A safety feature of the DBF4XLT and
r,
' DBF4XLT-705 is a visual indicator panel. This44
I provides the user with a visual indication of
I _ correct operation or, indication of a pressure �`'-�
y increase due to a blocked duct. This advanced
warning allows the user to take action to
1 I.
, clean the dryer exhaust duct.
1 i
That most dryers are limited to a
duct run of 35'?
N.- Using a DEDPV or Dryer Exhaust Fans can
I
n increase the duct run up to 130 ft, as the fan
i [ \
relieves the pressure in the extende� �EIV
ED
1.11111
i 0
allowing the dryer to work efficient) ,. , ,.... ,
�
4
•— f 21,42018 -
'3u LDING DEPART IEN '
I
61
Ul
n
Customer Support:
Canada 800.565.3548 • USA 800.747.1762 • support@fantech.net
Send Orders:
— orders@fantech.net • 877.747.8116 000
Fantech reserves the right to modify,at any time and without notice,any or all of its products'features, fafl'designs,components and specifications to maintain their technological leadership position. �!.•
•'' 09/21/2018
ASPEN
BUILDING DEPARTMENT