Loading...
HomeMy WebLinkAboutFile Documents.1300 Riverside Dr.0309.2017 (8).ARBK H.p,-Ku MAR 5020 County Road 154 Glenwood Springs, CO 81601 Geotechnical Engineering I Engineering Geology Phone: (970)945-7988 Materials Testing I Environmental Fax: (970)945-8454 Email: hpkglenwood@kumarusa.com Office Locations: Parker, Glenwood Springs, and Silverthorne, Colorado November 13, 2017 Revised November 16, 2017 S2 Architects Attn: Joseph Spears 215 South Monarch Street Aspen, Colorado 81611 (joseph@s2architects.com) Project No. 17-7-501 Subject: Percolation Testing, Lot 6, Block 1, Riverside Subdivision, 1300 Riverside Drive, Aspen, Colorado Gentlemen: As requested, H-P/Kumar performed percolation testing at the subject site on November 7, 2017 for surface water runoff disposal system design. The findings of our subsurface exploration and percolation test results are presented in this report. The test was performed as additional services to and in accordance with our proposal for professional engineering services with S2 Architects dated June 16, 2017. The percolation test was requested to be performed in a landscape area off Riverside Drive as shown on Figure 1 to meet City of Aspen requirements. An exploratory boring was drilled down into the natural silty sand and gravel soils and percolation testing was performed in the completed borehole, 11 feet deep. We returned to the site on November 15 and deepened the boring to below the groundwater level. A log of the exploratory boring is presented on Figure 2 and laboratory gradation test results are shown on Figure 3. The Natural Resources Conservation Service has identified four hydrologic soil groups in the Aspen area. The project site is located in Type B soil area having a moderate infiltration rate. Results of percolation testing performed at the test location are summarized in Table 1 and indicate a rate of about 5 minutes per inch. The groundwater level was encountered at a depth of 161 feet immediately following drilling and when checked the next day, the borehole was dry and had caved at 13 feet. In our experience, the caved depth is close to the groundwater level. If you have any questions or need further assistance,please call our office. Sincerely, •H-P.KUMAR c• .PA 40 Steven L. Pawlak, P ' I 6 2.2 2 SLP/kac . . 7//, Attachments: Figure : ' ''. t, •ratory Borings RECEIVED Figure 2�`` Off tr 'S- s tory Boring Figure 3—Gra• . • est Results 12/11/2 017 Table 1 —Percolation Test Results cc: Woody Creek Engineering—Josh Rice (josh@woodycreekengineering.com) ASPEN BUILDING DEPARTMENT LOT 71.99 - % I 7 F. - -�1C'Nc — % 1111 i 95 RLHAR&CAP ,1 `b�-�- - TYr:I 111 11/ LS hlR+is x i�+r'7 1 1 ry ..u��i IL ';• '�1 '\ f 7. .. v i MPS AIn I I '-0 ,44 '/1A � i �Pi , H11Ln1,:+.(N�L ,� i1i)5� ii%.1�,r ._ .='t1; ,I ' \LTHAY" . [% �•"�'�!�O� A`'i"'9t�r, �I /// iG V�1I .�\! P -- AIHVEL -1 v' y ,•V.I., /'/ I s - .�� a a' I r— ! \� --= c `y 1 I GASLINE J\ .,F \ GRAVEL I \\,A ` 1 I 1 PATH I I .f `I k I ..l� ! SLR I I I I. �4y' ,1,,0'-6'• / I ONE I I.Jf 4 f�_4 , `\ O T- . R.,yA1 S. .... AL14pYAY \ C-„a[ '1 ', it \ py���Y�\C\.Vs ;, , M,t ' ' BORING 1 R •7-- K5 REHAB•58 AP //61,4'S I •-. -—j3- -_— —.., Si.,F , I ..�I PA ti,vi� es REHAB S51 �4 •,T Y J��,�_ ki,\ , I 1 Iv"44k' F ::YY n i 1`r `nil;'• !,' —`;�') -VEL I __ c �I\t% i 4 Lre EI ' , P O CD — 4 1 x II ► ' ;, I � ii / , coT ��rf — I6 "PT / W I il 1 I I / \ 11 \ con, TEO J f _I- �� J^ I_ ' I I J .�' .uf OR {er \ \ f,HNOVJMELTEP _ ..0, _ PAVERS.1 \\\ fEAy. --� `y\ • �' BORING 2 L \`� I 'i; 1 PERV 00H f_`� _T`j.._-..__..._._...) �'1— 1 , s�-- Y-- -PPAVERS"— .1 R I ,r1y1 \E �' H4 I j LINE \ I I f 1 \OsA1G1P.AO rs� 16, 95 RPOAR&CAP i " __ L.S.K.776 1 C_i _—v._ TAM f:I.v901M.59' c x �of�. 9,— Y `H5 RFH.\R&CAP -Wag-. —' ' L.H Mills - _ i IR - - 1 -- { F g d i LEGEND: • BORING FOR CURRENT STUDY. ' 10 0 10 20 0 BORING FOR PREVIOUS STUDY APPROXIMATE SCALE—FEET DATED 7/5/17. RECE ���� iE €g 17-7-501 H—P-� MAR LOCATION OF EXPLORATORY BORINGS /111 /2017 ASPEN BUILDING DEPARTMENT BORING 2 LEGEND EL. 8001' 0 ,� ti TOPSOIL; ORGANIC SANDY SILT AND CLAY, DARK BROWN. a. - GRAVEL AND SAND (GM-SM); SILTY, SCATTERED — II 27/12 COBBLES, MEDIUMDENSETODENS , SLIGHTLY MOIST TO o MOIST WITH DEPTH, LIGHT BROWN. 5 , 26/12 — DRIVE SAMPLE, 2-INCH I.D. CALIFORNIA LINER SAMPLE. WC=4.0 J DD=�81 /27 12 DRIVE SAMPLE BLOW COUNT. INDICATES THAT 27 BLOWS OF — -200-13 A 140-POUND HAMMER FALLING 30 INCHES WERE REQUIRED ag0 TO DRIVE THE SAMPLER 12 INCHES. 10 Q DEPTH TO WATER LEVEL AND NUMBER OF DAYS AFTER w— i , 35/12 - DRILLING MEASUREMENT WAS MADE. — PRACTICAL AUGER REFUSAL. WHERE SHOWN ABOVE BOTTOM -t OF BORING, INDICATES THAT MULTIPLE ATTEMPTS WHERE a— MADE TO ADVANCE THE HOLE. w_ o —► DEPTH AT WHICH BORING CAVED WHEN CHECKED ON 15 NOVEMBER 16, 2017. S ° NOTES 1. THE EXPLORATORY BORING WAS DRILLED ON NOVEMBER 7, 2017 TO 11 FEET THEN DEEPENED TO 25 FEET ON NOVEMBER 20 15, 2017 WITH A 4-INCH DIAMETER CONTINUOUS FLIGHT POWER AUGER. — 2. THE LOCATION OF THE EXPLORATORY BORING WAS MEASURED APPROXIMATELY 3. THE ELEVATOXIMA ION OFBY THEPACING EXPLORATORYFROMFEATURES BORINGSHOWN WAS OBTAINEDONTHE 25 BY INTERPOLATION BETWEEN CONTOURS ON THE SITE PLAN PROVIDED. 4. THE EXPLORATORY BORING LOCATION AND ELEVATION SHOULD BE CONSIDERED ACCURATE ONLY TO THE DEGREE IMPLIED BY THE METHOD USED. 5. THE LINES BETWEEN MATERIALS SHOWN ON THE EXPLORATORY BORING LOG REPRESENT THE APPROXIMATE BOUNDARIES BETWEEN MATERIAL TYPES AND THE TRANSITIONS MAY BE GRADUAL. 6. GROUNDWATER WAS NOT INITIALLY ENCOUNTERED IN THE BORING AT THE TIME OF DRILLING BUT WAS ENCOUNTERED WHEN THE BORING WAS DEEPENED. FLUCTUATIONS IN WATER LEVEL MAY OCCURRED WITH TIME. 7. LABORATORY TEST RESULTS: WC = WATER CONTENT (%) (ASTM D 2216); DD = DRY DENSITY (pcf) (ASTM O 2216); +4 = PERCENTAGE RETAINED ON NO. 4 SIEVE (ASTM D 422); -200 = PERCENTAGE PASSING NO. 200 SIEVE (ASTM D 1140). P PECFVED 17-7-501 H-P--�KUMAR LOG OF EXPLORATORY BORING FiQ. 2 12/11 '2017 ASPEN BUILDING DEPARTMENT HYDROMETER ANALYSIS SIEVE ANALYSIS TINE READINGS U.S.STANDARD SERIES I CLEAR SQUARE OPENINGS 24 HR5 7 HRS 100 45 MIN )5 MIN SWAIN 19MIN 4MIN 1MJN /w0 /1D0 /SO/4a/30 /6 /1016 /4 3/Jf' 3 4' 1 2' �' Tr Q'0 r II I 1 90 ZiIII 10 BO20 70 30 6040P 250 50 4060 3070 2080 I 10 1 I 90 I 0 I I t I 1 I 1 I I ! till I 1I I I III I I I / I I III 11 I I I I l i i i I 100 .001 .002 .005 .009 .019 .037 .075 .150 .300 I .600 1.18 12.36 4.75 9.5 10 38.1 76.2 127 200 .425 2.0 152 I DIAMETER OF PARTICLES IN MILLIMETERS CLAY TO SILT SAND GRAVEL FINE MEDIUM COARSE FINE COARSE COBBLES GRAVEL 18 X SAND 69 X SILT AND CLAY 13 X LIQUID LIMIT PLASTICITY INDEX SAMPLE OF: Silty Sand with Gravel FROM: Boring 2 0 5' g 1 R 3 1 i These test results apply only to the samples which were tested. The E testing report shall not be reproduced, n except In full, without the written Siaieve analysis lasting Iroval of Kumar& MP.so at I o accordance with ASTM D42j VED "EE and/or ASTM D1140. `` 4 C 11 17-7-501 H-P-WUMAR GRADATION TEST RESULTS 0 4,/11/2017 ASPEN BUILDING DEPARTMENT P [CJMAQ? TABLE 1 PERCOLATION TEST RESULTS PROJECT NO. 17-7-501 HOLE NO. HOLE LENGTH OF WATER WATER DROP IN AVERAGE DEPTH INTERVAL DEPTH AT DEPTH AT WATER PERCOLATION (INCHES) (MIN) START OF END OF LEVEL RATE INTERVAL INTERVAL (INCHES) (MAIN./INCH) (INCHES) (INCHES) B-2 134 5 41 37 4 1 --- .3 37 34'/4 2% 1.8 34'/4 32 2% 2.2 32 30'/4 13/4 2.9 301/4 29 1'/4 4 29 273/4 11/4 4 273/4 263/4 1 5 263/4 253/4 1 5 J - - 253/4 243/4 1 5 Note: The percolation test was conducted in the completed 4-inch diameter borehole on November 7, 2017. RECEIVED 12/11/2017 ASPEN BUILDING DEPARTMENT