Loading...
HomeMy WebLinkAboutFile Documents.210 S 1st St.0281.2017 (46).ARBK GP Georgia-Pacific Gypsum ■ ■ ■ li ■ ■ xi' 1 11. . r. ail laa® i i Is al IIIIII Cl . i . NI , ■ 1,, r t .r Ili iI I�I .- De n sG I a ss° r Preferred substrateunder brick, stone, ne, stucco, siding and Sheathing Exterior Insulation and Finishing Systems (EIFS). IV' iI1B &: ; ri :. Lowil:,77.4,,,,. -.i. , . ii.,4 I , 1 . I. 1 A — - - -- - ii,. : . .a MOISTURE- AND MOLD-RESISTANT HIGH-PERFORMANCE SOLUTIONS DensGlass® Sheathing AtL Georgia-Pacific Gypsum Product Overview Coated Fiberglass Mats Moisture Resistant Gypsum Core DensGlass®Sheathing ©2010 Georgia-Pacific Gypsum LLC Table of Contents DensGlass°Sheathing has fiberglass mats for superior mold and moisture resistance Product Overview 2 compared to paper-faced sheathings. Physical Properties 4 • Fiberglass mats eliminate a potential food source for mold and may reduce remediation and scheduling delays associated with paper-faced drywall. Installation Recommendations 5 • Replaces traditional paper-faced sheathing. Wall Applications 5 • Backed with a 12-month limited warranty against in place weather exposure damage Fastening and Framing 7 (delamination,deterioration and decay).* Negative Uniform *For complete warranty details,visit wwwgpgypsum.com Lateral Loads 7 Soffit Applications,Fastening, When tested,as manufactured,in accordance with ASTM D 3273,DensGlass Sheathing Framing and Finishing 8 scored a 10,the highest level of performance for mold resistance under the ASTM D 3273 Soffit Board Comparison 9 test method. Air and Water Resistive Barriers 9 The score of 10,in the ASTM D 3273 test,indicates no mold growth in a 4-week controlled laboratory test.The mold resistance of any building product when used in actual job site Protection of Penetrations 9 conditions may not produce the same results as were achieved in the controlled, laboratory Fire-Rated Assemblies setting. No material can be considered mold proof.When properly used with good design, (Wood-Framed) 10 handling and construction practices,Dens'Brand gypsum products provide increased mold Fire-Rated Assemblies resistance compared to standard paper-faced wallboard. (Steel-Framed) 11 Available Sizes/Dimensions Architectural Specifications 13 DensGlass Sheathing is available in 1/2"(12.7 mm)thickness and DensGlass®Fireguard® Limitations 15 Sheathing is available in 5/8"(15.9 mm)thickness. DensGlass Sheathing is manufactured Commonly Used Metric in a 4'(1219 mm)width and 8'(2438 mm),9'(2743 mm)and 10'(3048 mm)lengths. Other Conversions 15 lengths are available upon request. CAUTION:For product fire,safety and use information,go to gp.com/safetyinfo. 2• For latest information and updates:Technical Service Hotline 1.800.225.6119 or www.gpgypsum.com DensGlass® Sheathing Atk Georgia-Pacific Gypsum DensGlass®Sheathing is the preferred substrate under brick,stone,stucco,siding and Exterior Insulation and Finishing Systems (EIFS)because of its exemplary track record.DensGlass Sheathing should be specified for any project where flexibility and easy sheathing installation are paramount without the headaches and expense of delamination,deterioration,sagging and warping.Look for the distinctive GOLD color to ensure you're using genuine DensGlass Sheathing. Mold Resistance Independent tests confirm that DensGlass Sheathing,with its patented fiberglass mat design,resists the growth of mold when tested,as manufactured,per ASTM D 3273. Strength Fiberglass mats penetrate into the panel to make an integrated unit that offers superb strength;outstanding resistance to delamination, deterioration,warping and job site damage;and an excellent bonding surface for EIFS.The flexural strength of DensGlass Sheathing is approximately the same in both directions.This means DensGlass Sheathing can be installed either vertically or horizontally without sacrificing wall strength between studs.DensGlass panels also protect and help stabilize structural framing. Stability DensGlass Sheathing is extremely resistant to rippling,buckling and sagging,even under humid conditions—which makes it particularly suitable for soffits. In actual tests, DensGlass panels exceeded ASTM C 1396 and ASTM C 79 standards for humidified deflection by a factor of five times over the standard for paper-faced gypsum sheathing. Fire Resistance DensGlass Sheathing is noncombustible as described and tested in accordance with ASTM E 136.Tests of 5/8"(15.9 mm) DensGlass®Fireguard®Sheathing conducted in accordance with ASTM E 119/CAN ULC S-101 qualify the product for a variety of UL listings and other designs in the GA-600 Fire Resistance Design Manual. Superior Weather Protection DensGlass Sheathing integrates a water-resistant,treated core with a fiberglass mat face and back to provide superb protection from the elements.Panels will not delaminate or deteriorate due to normal weather conditions—even during construction delays that last as long as 12 months after installation. A water-resistive barrier is not required over DensGlass Sheathing to provide for the protection of the gypsum sheathing itself.Consult with the local building code,design professional,owner or cladding manufacturer for water-resistive barrier requirements. DensGlass Sheathing is the ideal substrate for a wide variety of air and water-resistive barriers including building wraps,liquid applied coatings and self-adhering membranes. See page 9 for details. Easy to Handle DensGlass Sheathing is lightweight and easy to handle. It can be cut and fastened with standard drywall tools and fasteners. The product is much easier to work with than wood substrate,cement board or fiber cement sheathing,which tend to be heavy and bulky. Outstanding Warranty DensGlass Sheathing is covered by a 12-month limited warranty for weather exposure,a five-year limited warranty against manufacturing defects and a 12-year limited warranty when used as a substrate for architecturally specified EIFS. For a copy of the limited warranty,call 1-800-225-6119.Or visit our Web site at www.gpgypsum.com. Standards and Code Compliance DensGlass Sheathing is manufactured to meet ASTM C 1177.Application standards where applicable are in accordance with Gypsum Association Publication GA-253 for gypsum sheathing or ASTM C 1280. Evaluated by: • ICC-ES Legacy Report NER 574 • CCMC-12064-R • ICC-ES Legacy Report ER 4305 • N.Y.City MEA 244-88-M • Florida Product Approval Code FL 2524-R3 The data relating to fire-and sound-tested assemblies is based on the characteristics,properties and performance of materials and systems obtained under controlled test conditions as set forth under the appropriate ASTM standard,such as E 119(fire), E 90(sound)or E 72(structural). Georgia-Pacific Gypsum Products and LEED® Many of our products may contribute to LEED®credits.To find out more,please reference the Sustainable Materials Data Sheets (SMDS)on our website(www.gpgypsum.com)for recycled content,regional materials, low emitting materials and other potential categories for LEED credit contributions. CAUTION:For product fire,safety and use information,go to gp.com/safetyinfo. For latest information and updates.Technical Service Hotline 1.800.225.6119 or www.gpgypsum.com •3 AtGeorgia-Pacific DensGlass® Sheathing LGypsum Physical Properties Product Comparison 5/8"(15.9 mm) 5/8"(15.9 mm) 1/2"(12.7 mm) 1/2"(12.7 mm) DensGlass® Gypsum Sheathing, DensGlass Regular Gypsum Fireguard® Type X(Paper-faced) Sheathing Sheathing (Paper-faced) Width,Nominal 4'(1219 mm) 4'(1219 mm) 4'(1219 mm) 4'(1219 mm) Length,Standard 8',9',10' 8',9',10' 8',9',10' 8',9',10' (2438,2743,3048 mm) (2438,2743,3048 mm) (2438,2743,3048 mm) (2438,2743,3048 mm) 1/4"(6 mm) 1/4"(6 mm) 1/4"(6 mm) 1/4"(6 mm) Weight/lbs/SF(kg/m2) 2.5(12) 2.2(11) 1.9(9) 1.9(9) Bending Radius 8'(2438 mm►8 n/a ' 6'(1829 mm)8 n/a Composition Fiberglass mats Paper facings Fiberglass mats Paper facings gypsum core gypsum core gypsum core gypsum core Racking Strength,lbs./ft.(dry)(N/m) >654' 654' >5409 540' (Ultimate-not design value) (>9544) (9544) (>7878) (7878) Flexural Strength,'parallel,lbf.(N) 100'(445) 502(222) 80'(356) 402(178) (4'weak direction) Compressive Strength min.500 psi min.400 psi min.500 psi min.350 psi (3445 kPa) (2750 kPa) (3445 kPa) (2400 kPa) Humidified Deflection'"inches 1/8"(3 mm) 5/8"(15.9 mm) 2/8"(6 mm) 10/8"(32 mm) Permeance(perms►5[ng/Pa•s•m2] 17[970] 25[1400] 23[1300] 27[1600] "R"Values °F•ftz•hr/BTU(K•m2/w) .67(0.118) .56(0.099) .56(0.099) .45(0.079) Combustibility10 Noncombustible Combustible Noncombustible Combustible Linear Expansion with Change 6.25 x 10-6 7.5 x 10-6 6.25 x 10-6 7.5 x 10-6 Moisture in/in/%RH(mm/mm%RH) Flame Spread,E84 CAN ULC-S102 10 15 10 15 Coefficient of Thermal Expansion 8.5 x 10-6 10 x 10-6 8.5 x 10-6 10 x 10-6 in/in/°F(mm/mm/°C) (15.3 x 10-6) (18 x 10-0) (15.3 x 10-0) (18 x 10-0) Resists Growth of Mold(tested,as Yes No Yes No manufactured,per ASTM D 3273) Handling Characteristic Scores with utility Scores with utility Scores with utility Scores with utility knife and snaps easily knife and snaps easily knife and snaps easily knife and snaps easily Fasteners Standard Standard Standard Standard 1.Gypsum Association-GA-253 6. Tested in accordance with ASTM C 518(heat flow meter) 2.Minimum requirements for ASTM C 1396 7.Minimum requirements for ASTM C 1177 3.Maximum requirements for ASTM C 1396 8.Double fasteners on ends as needed 4. Tested in accordance with ASTM C 473 9. Tested in accordance with ASTM E 72 5. Tested in accordance with ASTM E 96(dry cup method) 10.As defined and tested in accordance with ASTM E 136 CAUTION:For product fire,safety and use information,go to gp.com/safetyinfo. 4• For latest information and updates:Technical Service Hotline 1.800.225.6119 or www.gpgypsum.com DensGlass® Sheathing Atk Georgia-Pacific Gypsum Installation Recommendations • DensGlass®Sheathing must be installed in accordance with the instructions in this brochure,Gypsum Association document GA-253 or ASTM C 1280.DensGlass Sheathing can be attached parallel or perpendicular to wood or metal framing. Use appropriate board orientation for specific fire assemblies and shear wall applications within this document,other reference documents or as required by designing authority.The framing width shall not be less than 1-1/2"(38 mm)wide for wood framing and 1-1/4"(32 mm)for steel framing. Framing members shall not vary more than 1/8"(3 mm)from the plane of the faces of adjacent framing. • Fasteners should be driven flush with the panel surface(not countersunk)and into the framing system.Locate fasteners at least 3/8"(9 mm)from the ends and edges of the sheathing. Nails or screws,as listed in the fastener chart,may be used to attach DensGlass Sheathing to framing.When a pneumatic fastening system into metal is specified to attach DensGlass Sheathing,consult with manufacturer for application specifications and shear resistance data. DensGlass Sheathing is not to be used as a base for nailing or other fastening. • Install DensGlass Sheathing with end joints staggered on horizontal applications. Ends and edges of the sheathing should fit tightly. DensGlass Sheathing panels shall not be less than 8"(203 mm)from the finish grade in fully weather-and water- protected siding systems,and not less than 12"(305 mm)from the ground for properly drained and ventilated crawl spaces. Consult with the design authority for control joint recommendations. Wall Applications Installing Cladding over DensGlass Exterior Sheathing Most conventional exterior sidings and wall coverings—including wood,vinyl,composition,metal,stone,brick,wood shingles, shakes and plywood panels—may be applied over DensGlass Sheathing. Consult your local building codes for water resistive barriers(WRB)requirements. A. DensGlass Sheathing G. Brick Masonry or Stone Veneer L. Fiber Cement Siding B. Insulation H. Flashing and Weeps M. Metal Siding C. Framing I. Wood Shingles or Shakes D. Water-Resistive Barrier J. Plywood Siding E. Masonry Tie K. Vinyl Siding F. 2"(50mm)Max.Air Space , Brick Cavity Wall ' /0 440.1 L� Masonry or stone veneer can be applied over DensGlass 0:4 ____eres1WSheathing just as it would be over any other type of sheathing. E Attach the masonry ties securely through the panels and into the F �_�= steel or wood framing.Space the ties as required by masonry _=0-__�� courses.Apply water-resistive barrier as required by building code ��____ or design authority. Shingles,Shakes,Vinyl,Metal,Wood, - J Fiber Cement Siding c � O DensGlass Sheathing can be used in applications such as under wood shakes or shingles,plywood panel siding or other horizontal siding applications.All siding must be attached through the ©DensGlass Sheathing and into the steel or wood framing.Apply water-resistive barrier as required by building code or designVor authority. Illustrations not intended for design or specification purposes. CAUTION:For product fire,safety and use information,go to gp.com/safetyinfo. For latest information and updates.Technical Service Hotline 1.800.225.6119 or www.gpgypsum.com • 5 AtGeorgia-Pacific DensGlass® Sheathing kGypsum Wall Applications continued A. DensGlass®Sheathing r \- B. Insulation • C. Framing 0 D. Paper-Backed Metal Lath • Cy 0 ; E. Conventional Stucco 0 F. Minimum 1/4"(6 mm)Gap 4.40 Conventional Stucco .�. Stucco systems may be applied over DensGlass Sheathing using 0 paper-backed metal lath.Paper-backed metal lath must be mechanically attached through the DensGlass Sheathing into the steel or wood framing. Install stucco system in accordance with the manufacturer's instructions,the Portland Cement Association guidelines and local building code requirements. Exterior Insulation and Finish Systems(EIFS) DensGlass Sheathing is an ideal substrate for adhesive or mechanical application of expanded polystyrene(EPS)or extruded polystyrene insulation in EIFS applications and is recommended for all climate zones. DensGlass Sheathing is designated as the preferred gypsum substrate for EIFS by EIMA,the EIFS industry members association, in the EIFS Durability Specifications Guideline. DensGlass panels are treated with an exclusive GOLD color primer coating. This coating,proprietary to Georgia-Pacific Gypsum and developed especially for DensGlass Sheathing,has several important advantages for EIFS applications: • Eliminates the need for sealer/primer with adhesively applied EIFS. • Strengthens the bond between panel and surfacing product. • Makes the panel more resistant to surface water.The result: labor cost and callbacks go down while customer satisfaction on each project goes up. • 12-year limited warranty when used in an architecturally specified EIFS application. • Maximum framing spacing 16"(406 mm)o.c.for 1/2"(12.7 mm)and 24"(610 mm)o.c.for 5/8"(15.9 mm)DensGlass® Fireguard°Sheathing. A. DensGlass Sheathing '-- .� I B. Adhesive or Mechanically Attached 0 C. Polystyrene Insulation D. Reinforcing Mesh Embedded in Base Coat E. Finish Coat �i High Velocity Hurricane Zone(HVHZ) The ability to withstand the destructive winds and the impact of various objects during a hurricane in a coastal area is key to the survival of any exterior cladding system. DensGlass Sheathing from Georgia-Pacific Gypsum helps BASF,Sto Corp, Dryvit,Parex Lahabra,Inc.,Fiberweb,Inc.and Wellbilt International's systems pass the strict Miami-Dade County and Florida Building Code requirements for High Velocity Hurricane Zones(HVHZ).The systems were tested independently to determine the performance against specific criteria for impact resistance,air and water infiltration resistance and wind load resistance. For more information, please visit www.gpgypsum.com or contact the system manufacturer. CAUTION:For product fire,safety and use information,go to gp.com/safetyinfo. 6• For latest information and updates:Technical Service Hotline 1.800.225.6119 or www.gpgypsum.com DensGlass® Sheathing Atk Georgia-Pacific Gypsum Fastening and Framing Thickness Framing Spacing Panel Orientation Fastener Spacing—Wood Framing" Fastener Spacing—Metal Framing" 1/2"(12.7 mm) 24"(610 mm)o.c.max'3 Parallel3 or Perpendicular 8"(203 mm)o.c.field2&perimeter 8"(203 mm)o.c.along framing 5/8"(15.9 mm) 24"(610 mm)o.c.maxi Parallel3 or Perpendicular 8"(203 mm)o.c.field2&perimeter 8"(203 mm)o.c.along framing 1.Only for mechanically attached claddings.When specified behind EIFS,maximum framing spacing for 1/2"(12.7 mm)DensGlass®Sheathing is 16"(406 mm)o.c. 2.Fastener spacing around the perimeter of the wall and along intermediate vertical framing members.To meet the racking shear strength listed in the physical properties table,fastener spacing is 4"(102 mm)o.c.around the perimeter of each panel and 8"(203 mm)o.c.along vertical framing members. 3.For racking strength resistance apply panel edges parallel with framing spaced a maximum of 16"(406 mm)o.c.for both 1/2"(127 mm)and 5/8"(15.9 mm) DensGlass Sheathing. 4.Fire-rated assemblies may require additional fasteners,see specific assembly details. Fastener* I Length Application 1/2"Thick 5/8"Thick 1"(25 mm) 1-1/4"(32 mm) Bugle head fine thread, DensGlass Sheathing to rust-resistant drill point heavy-gauge steel drywall screw 1"(25 mm) 1-1/4"(32 mm) Bugle head fine thread, DensGlass Sheathing to light- rust-resistant sharp point gauge metal framing furring drywall screw 1-1/4"(32 mm) 1-5/8"(41 mm) Bugle head,rust-resistant, DensGlass Sheathing to r. coarse thread sharp wood framing point screw 1-1/4"(32 mm) 1-1/4"(32 mm)metal Wafer head, DensGlass Sheathing to 1-5/8"(41 mm)wood rust-resistant screws, heavy-gauge or light-gauge, drill or sharp point metal or wood,respectively 1-1/2"(38 mm) 1-3/4"(45 mm) 11-gauge,galvanized nail DensGlass Sheathing to wood framing or equivalent *For screws,meet or exceed ASTM C 1002 or C954.Contact fastener manufacturer for correct amount of corrosion resistance. Negative Uniform Lateral Loads (Wind Load) 5/8"(15.9 mm) DensGlass°Fireguard®Sheathing Horizontally Applied Stud Spacing, Screws, Ultimate load, NOTE Apply DensGlass Sheathing to appropriately engineered framing system. In./O.C.(mm) In./O.C.(mm) PSF*(kPa) Tested applied to 6"(152mm)x 1-5/8"(41 mm)18-gauge(43 mils)steel studs using#6 1-1/4" 16(406) 8(203) 127(6.08) (32 mm)bugle head screws.Other stud sizes may be suitable. 16(406) 6(152) 142(6.80) Source:Tested in accordance with ASTM E 330 by Hurricane Test Laboratory.For a copy of 16(406) 4(102) 192(9.19) report#G488-1001-07,contact Georgia-Pacific Gypsum Technical Hotline at 1-800-225-6119. 12(305) 8(203) 157(7.51) *Maximum load capacity(not design load)of the 5/8"(15.9 mm)DensGlass Fireguard 12(305) 6(152) 204(9.77) Sheathing applied horizontally.Apply appropriate safety factor from the design method 12(305) 4(102) 270(12.93) used to calculate design load.For example,a safety factor of 3 applied to an ultimate 8(203) 8(203) 208(9.96) load of 127psf(6.08 kPa)results in a design load of 42 psf(2.01 kPa). 8(203) 6(152) 354(16.95) 8(203) 4(102) 410(19.63) 1/2"(12.7 mm)and 5/8"(15.9 mm)DensGlass Fireguard Sheathing Vertically or Horizontally Applied Thickness Board Stud Spacing Ultimate Load Source:TPI Report#89-047;wind load per ASTM E330 Inches(mm) Orientation in.o.c.(mm) Psf(kPa►, (bugle head screws 8"(203 mm)o.c.) 1/2"(12.7) Vertical 16(406) 65(3.11) 1/2"(12.7) Horizontal 16(406) 70(3.35) 5/8"(15.9) Vertical 24(610) 68(3.26) 5/8"(15.9) Horizontal _ 24(610) 85(4.07) 5/8"(15.9) Vertical 16(406) 92(4.40) CAUTION:For product fire,safety and use information,go to gp.com/safetyinfo. For latest information and updates.Technical Service Hotline 1.800.225.6119 or www.gpgypsum.com • 7 AtGeorgia-Pacific DensGlass® Sheathing LGypsum Soffit Applications, Fastening, Framing and Finishing Method#1 Method#2 Painted Ceilings and Soffits Exterior Ceilings and Soffits Finished Joints i IIIII O® O 1".11:111111117 0 O A. DensGlass®Sheathingtira° %i= :: ..;0 B. Drip Edge ° C. Reinforcing Mesh/Base Coat ° 0 D. Base Coat E. Finish Coat —o F. 2"(51 mm)Fiberglass Mesh Tape Z G. ToughRock®Setting Compound* *Sandable setting compounds are not recommended. Thickness Framing Spacing Orientation J Screw Spacing 1/2"(12.7 mm) 16"(406 mm)o.c.max Parallel or Perpendicular 8"(203 mm)o.c.along framing 1/2"(12.7 mm) 24"(610 mm)o.c.max Perpendicular 24"o.c.framing 8"(203 mm)o.c.along framing 5/8"(15.9 mm) 24"(610 mm)o.c.max Parallel or Perpendicular 8"(203 mm)o.c.along framing Method#1 Embed 2"(51 mm)wide fiberglass mesh tape in ToughRock®90 Setting Type joint compound,or equivalent,over all joints. Once dry,apply a skim coat of ToughRock 90 setting compound,or equivalent,over the panels to achieve a uniform,smooth finish over the entire area. Prime with exterior-grade primer and finish with two coats of exterior-grade paint. Method#2 Apply a synthetic-type Direct Applied Finish System in accordance with the coating manufacturer's recommendation. Special Conditions: 1. Control joints are recommended a maximum of 30 feet(9144 mm)or closer as specified by the design authority. 2.The roof must be dried in or protection from the elements must be provided prior to installing DensGlass Sheathing in horizontal applications to prevent moisture from ponding or settling on top of the sheathing panel or within the finished soffit. 3.Sandable setting compounds are not acceptable for use over DensGlass Sheathing in exterior soffit applications. 4. Georgia-Pacific Gypsum's ToughRock 90 setting compound is not available in all markets. It is permissible to use setting-type joint compounds from other manufacturers that are equivalent to ToughRock 90 setting compound. CAUTION:For product fire,safety and use information,go to gp.com/safetyinfo. 8• For latest information and updates:Technical Service Hotline 1.800.225.6119 or www.gpgypsum.com DensGlass® Sheathing Atk Georgia-Pacific Gypsum Soffit Board Comparison Product Comparison 1/2"(12.7 mm) 1/2"(12.7 mm)Gypsum 5/8"(15.9 mm) 5/8"(15.9 mm)Gypsum DensGlass® Soffit Board(Paper-faced) DensGlass Sheathing Soffit Board(Paper-faced) Humidified Deflection'(Sag) 2/8"(6 mm) 7/8"(22 mm) 1/8"(3 mm) 4/8"(13 mm) Water Absorption' <10% 40% <10% 40% Surface Water Absorption' .83 grams 2.5 grams .83 grams 2.5 grams Surface Fiberglass mat Paper-faced Fiberglass mat Paper-faced 1. Specified values for DensGlass Sheathing are found in ASTM C 1177,ASTMC 1396 and ASTM C 931 for gypsum soffit board,tested in accordance with ASTM C 473. Air- and Water-Resistive Barriers The need for moisture control,greater energy savings,comfort and improved environment is driving the use of air-and water- resistive barriers. Manufacturers,building codes and standards organizations are improving the ways moisture is controlled in buildings. DensGlass®Sheathing has been widely accepted for years as the preferred substrate with these systems and provides superior performance over other sheathings.The ultimate in wall performance and peace of mind is starting with the best substrate—DensGlass Sheathing. DensGlass Sheathing is a superior substrate for a wide variety of air and water-resistive systems which include: • #15 asphalt felt,ASTM D 226,type 1 or equivalent • Synthetic wraps such as Tyvek®,Typar®MetroWrap®,ASTM E 1677 or equivalent • Liquid-or fluid-applied air or vapor barriers such as Tremco ExoAir®120,Grace Perm-A-Barrier®VP,Henry Air-BlocT""32 or Carlisle Barriseal° • Water barrier systems such as Sto Guard°as manufactured by Sto Corp.,Dryvit's Backstop°NT,Prosoco R-GUARD' or equivalent • Asphalt-based coatings • Self-adhering membranes such as Carlisle CCW,Grace Perm-A-Barrier®, Henry Air-Bloc Vapor Barriers,Protecto Wrap • Water-resistive barrier and drainage membranes such as DELTA-DRY® Follow manufacturer's installation recommendations for use with DensGlass panels, local building code requirements and design authority's specifications. Note:It is not required to provide a water-resistive barrier over DensGlass Sheathing for the protection of the gypsum sheathing itself during the 12-month weather exposure limited warranty.Consult with local building code,design professional,owner or cladding manufacturer for water-resistive barrier requirements and compatibility with the wall cladding. Protection of Penetrations All penetrations should be protected to prevent air and water infiltration.Follow building code,door/window manufacturer,or design authority's recommendations for flashing around openings,abutments to dissimilar materials and wall terminations. In areas that do not prescribe to current code requirements but still require long-term joint protection,either of the following two methods may be specified in lieu of an air-and water-resistive barrier system: Method 1)Apply minimum 3/8"(9 mm) bead of sealant to joints and trowel to provide a layer approximately 2"(51 mm)wide by 1/16"(2 mm)thick spanning the joint. Use backer rod for openings larger than 1/8"(3 mm).Method 2)Apply glass mesh joint tape to all joints,overlapping at intersections by the width of the tape.Apply approximately 3/8"(9 mm)bead of caulk along the joint. Embed the caulk into the entire surface of the tape with a trowel. Use backer rod for openings larger than 1/8"(3 mm). Follow manufacturer's installation recommendations for use with DensGlass Sheathing,and design authority specifications. A variety of caulk and polymer-based "fill" materials may be specified, including GE, Dow Corning,Tremco, Sto, Dryvit,BASF and Proseco. Please contact the caulk manufacturer for its recommended caulks over DensGlass Sheathing. CAUTION:For product fire,safety and use information,go to gp.com/safetyinfo. For latest information and updates.Technical Service Hotline 1.800.225.6119 or www.gpgypsum.com • 9 AtGeorgia-Pacific DensGlass® Sheathing &Gypsum Fire-Rated Assemblies (Wood-Framed►'continued Design assemblies for illustrative purposes only.Consult appropriate fire resistance directory for assembly information.See Fire Safety Caution on back panel. 1-Hour Fire Rating Test Reference:UL U305,U337,WHI 495-0702,ULC W301,GA WP 5515 Wall Thickness:4-7/8"(124 mm) EXTERIOR __ Weight per Sq.Ft.:7.5(37 kg/m2) XX Exterior:5/8""(15.9 mm)DensGlass®Fireguard°Sheathing applied parallel(U337, W301,U305)or at right angles(U305)to 2 x 4 wood studs 16"(406 mm)o.c.with - - _ - _ -_ 1-3/4"(45 mm)galvanized roofing nails 7"(178 mm)o.c.for all framing members. Exterior surface covered with weather exposed cladding or finish system. Interior:5/8"(15.9 mm)DensArmor Plus°Fireguard°interior panels or 5/8"(15.9 mm) ToughRock®Fireguard°gypsum board applied parallel or at right angles to studs with 1-7/8"(48 mm)6d coated nails 7"(178 mm)o.c.Stagger joints each side.(Load-bearing) 1-Hour Fire Rating Test Reference:UL U309,cUL U309 EXTERIOR Wall Thickness:4-7/8"(124 mm) f -i - - - - --_--__ _ -- - -_ _ Weight perSq.Ft.:7.5(37kg/m2) X X Exterior:5/8""(15.9 mm)DensGlass Fireguard Sheathing applied parallel or at right angles to 2 x 4 wood studs spaced 24"(610 mm)o.c.with 1-7/8"(48 mm)galvanized - - roofing nails 7"(178 mm)o.c. Interior:5/8"(15.9 mm)DensArmor Plus Fireguard or 5/8"(15.9 mm)ToughRock Fireguard gypsum board to framing with 1-7/8"(48 mm)6d coated nails 7"(178 mm)o.c. (Load-bearing) 2-Hour Fire Rating Test Reference:UL U301,cUL U301 EXTERIOR Wall Thickness:6-1/8"(156 mm) t--_ _- -__--- _- -__-_-- _- -__--- _- -__-- Weight per Sq.Ft.:12.5(61 kg/m2) X X Exterior:Two layers 5/8""(15.9 mm)DensGlass Fireguard Sheathing applied parallel or /J�\ at right angles to 2 x 4 wood studs 16"(406 mm)o.c.Base layer attached with 1-7/8" (48 mm)galvanized roofing nails 16" (406 mm)o.c.Face layer attached with 2-3/8" (60 mm)galvanized roofing nails 8"(203 mm)o.c.Stagger joints between layers and on base layer of both sides. Interior:Two layers 5/8"(15.9 mm)DensArmor Plus Fireguard or 5/8"(15.9 mm) ToughRock Fireguard gypsum board applied horizontally or vertically to framing.Base layer attached with 1-7/8"(48 mm)6d cement coated nails 6"(152 mm)o.c.Face layer attached with 2-3/8"(60 mm)6d cement coated nails 8"(203 mm)o.c.Stagger joints between layers and on base layer of both sides.(Load-bearing) 2-Hour Fire Rating Test Reference:UL U302,cUL U302,GA WP 8410 EXTERIOR Wall Thickness:10-1/8"(257 mm) Exterior:One layer 1/2"(12.7 mm)DensGlass Sheathing applied parallel or at right r - - - - - - angles to studs with 1-3/4"(45 mm)galvanized roofing nails 6"(152 mm)o.c.Face X \/ layer is 2"x 4"x 8"(51 mm x 102 mm x 203 mm)clay brick with 1"(25 mm)air space !...__ between brick and exterior sheathing.20-gauge(30 mils)galvanized wire ties attached _--_ ___a__:. am.=� .��-= to each stud with 8d coated nails as described above,located at every sixth course of ` ' " ` ' " ' bricks.(Load-bearing) Interior:Two layers 5/8"(15.9 mm)DensArmor Plus Fireguard or 5/8"(15.9 mm) ToughRock Fireguard gypsum board applied parallel or at right angles to 2 x 4 wood studs 16"(406 mm)o.c.Base layer attached with 1-7/8"(48 mm)6d coated nails 8" (203 mm)o.c.Face layer attached with 2-3/8"(60 mm)coated nails 8"(203 mm)o.c. 'Load restricted for Canadian applications—see UL Guide BXUV7. CAUTION:For product fire,safety and use information,go to gp.com/safetyinfo. 10 • For latest information and updates.Technical Service Hotline 1.800.225.6119 or www.gpgypsum.com DensGlass® Sheathing Atk Georgia-Pacific Gypsum Fire-Rated Assemblies (Wood-Framed►'continued 2-Hour Fire Rating Test Reference:UC 12-21-67,GAWP 8420 Wall Thickness:8-5/8"(219 mm) FIRE SIDE Exterior:Base layer 5/8"(15.9 mm)DensGlass®Fireguard®Sheathing retardant treated - 2 x 6 wood studs 16"(406 mm)o.c.with 6d coated nails,1-7/8"(48 mm)long,0.0915" (2 mm)shank,1/4"(6 mm)heads,12"(305 mm)o.c.and covered with a single layer fire resistant protective weather retarder paper stapled along each edge at 16"(406 mm) o.c.Galvanized self-furring wire mesh applied over sheathing with 8d galvanized roofing nails,2-3/8"(60 mm)long,0.113"(3 mm)shank,9/32"(7 mm)heads,6"(152 mm)o.c. Cement-stucco applied over wire mesh in two 1/2"(12.7 mm)thick coats with bonding agent applied between coats. Interior:Base layer 5/8"(15.9 mm)DensArmor Plus®Fireguard®or 5/8"(15.9 mm) ToughRock®Fireguard®applied parallel to studs with 6d coated nails,1-7/8"(48 mm) long,0.0915"(2 mm)shank,1/4"(6 mm)heads,12"(305 mm)o.c.Face layer 5/8" (15.9 mm)DensArmor Plus Fireguard or 5/8"(15.9 mm)ToughRock Fireguard applied at right angles to studs with 8d coated nails,2-3/8"(60 mm)long,0.113"(3 mm)shank, 9/32"(7 mm)heads,8"(203 mm)o.c.at edges and 12"(305 mm)o.c.at intermediate studs.(Load-bearing) Fire-Rated Assemblies (Steel-Framed) 1-Hour Fire Rating Test Reference:UL U465,ULC W415,cUL U465,GA WP 1081 Wall Thickness:4-7/8"(124 mm) EXTERIOR flIT: W Sq. 6 psf m2) Exterior:eightper 5/8"(15.9Ft.:mm)DensGlass(29kg/ Fireguard Sheathing applied vertically to mi .3-5/8" (92 mm)corrosion resistant 25-gauge(18 mils)steel studs 24"(610 mm)o.c.with 1" - ITT — (25 mm)corrosion resistant bugle head screws 8"(203 mm)o.c.at board edges and 8" (203 mm)at intermediate studs. Interior:5/8"(15.9 mm)DensArmor Plus Fireguard or 5/8"(15.9 mm)ToughRock Fireguard gypsum board applied vertically to framing with 1"(25 mm)Type S bugle head screws 8"(203 mm)o.c.at board edges and 12"(305 mm)at intermediate studs. 1-Hour Fire Rating Test Reference:UL U425,'cUL U425 EXTERIOR Wall Thickness:4-3/4"(121 mm) _ _ _ _ _ Weight per Sq.Ft.:6 psf(29 kg/m2) Exterior:5/8"(15.9 mm)DensGlass®Sheathing applied vertically to min.3-1/2"(89 mm) corrosion resistant 20-gauge(30 mils)steel studs 24"(610 mm)o.c.with 1"(25 mm) '~— Type S corrosion resistant bugle head screws 8"(203 mm)o.c. Interior:5/8"(15.9 mm)DensArmor Plus Fireguard or 5/8"(15.9 mm)ToughRock Fireguard gypsum board applied vertically to framing with 1"(25 mm)Type S bugle head screws 121305 mm)o.c.Insulation to completely fill stud cavity.(Load-bearing: 100%of design load) 'Load restricted for Canadian applications—see UL Guide BXUV7. CAUTION:For product fire,safety and use information,go to gp.com/safetyinfo. For latest information and updates:Technical Service Hotline 1.800.225.6119 or www.gpgypsum.com • 11 AtGeorgia-Pacific DensGlass® Sheathing LGypsum Fire-Rated Assemblies (Steel-Framed) continued 1-Hour Fire Rating Test Reference:SWRI 01-4409-003,GA WP 8122 �� ������������������� ��������������� Partition Thickness:6"-7"(152-178 mm)Varies based on insulation thickness 4.•_.••-•.*.�%������.•..•_.*4�.��� Weight per Sq.Ft.:7.0(34 kg/mz) - - - - - - ' — - - - Exterior:5/8"(15.9 mm)DensGlass°Fireguard°Sheathing applied parallel to 3-5/8" (92 mm)18-gauge(43 mils)steel studs 16"(406 mm)o.c.with#6 x 1-1/4"(32 mm) self-drilling,corrosion-resistant,bugle head,drywall screws 8"(203 mm)o.c.at edges -- - - - -- - - -- - - -- - - and ends and 8"(203 mm)o.c.at intermediate studs.Proprietary polymer modified exterior insulation and finish system applied over sheathing.2"(51 mm)maximum foam-plastic thickness. Interior:5/8"(15.9 mm)ToughRock°Fireguard°or 5/8"(15.9 mm)DensArmor Plus° Fireguard°gypsum board applied parallel to studs with#6 x 1-1/4"(32 mm)self-drilling, bugle head drywall screws 8"(203 mm)o.c.at edges and ends and 12"(305 mm)o.c.at intermediate studs. 1-Hour Fire Rating Test Reference:SWRI 01-4409-001,GA WP 8123 ��-� �� ���.� _�����_�� Partition Thickness:6"-9"(152-229 mm)Varies based on insulation thickness G�O�:��:iO���i�:�i:��i��ii:��i�:ii=iO��!•_*4 Wei ght per Sq.Ft.:7.0(34 kg/mz) — - - - - - Exterior:5/8"(15.9 mm)DensGlass Fireguard Sheathing applied parallel to 3-5/8"(92 mm) 18-gauge(43 mils)steel studs 24"(610 mm)o.c.with#6 x 1-1/4"(32 mm)self-drilling, corrosion-resistant,bugle head,drywall screws 8"(203 mm)o.c.at edges and ends and 8" - = -r==------'------ (203 mm)o.c.at intermediate studs.Polymer-based exterior insulation and finish system applied over sheathing.4"(102 mm)maximum foam-on-plastic thickness. Interior:One layer 5/8"(15.9 mm)ToughRock Fireguard or 5/8"(15.9 mm)DensArmor Plus Fireguard gypsum board applied parallel to studs with#6 x 1-1/4"(32 mm)self-drilling, bugle head drywall screws 8"(203 mm)o.c.at edges and ends and 12"(305 mm)o.c.at intermediate studs. 2-Hour Fire Rating Test Reference:UL U4251,cUL U425 EXTERIOR Wall Thickness:6"(152 mm) -_ - -_ -_ --- -- - -- -- - -- Weight per Sq.Ft.:11.0 psf(54 kg/m2) - Exterior:Two layers 5/8"(15.9 mm)DensGlass Fireguard Sheathing applied vertically to min.3-1/2"(89 mm)corrosion resistant 20-gauge(30 mils)steel studs 24"(610 mm)o.c. Base layer attached with 1"(25 mm)Type S-12 corrosion resistant bugle head screws 8" - +_ - +_ - -_ - — (203 mm)o.c.Face layer attached with 1-5/8"(41 mm)Type S-12 corrosion resistant bugle head screws spaced 8"(203 mm)o.c.Joints staggered. Interior:Two layers 5/8"(15.9 mm)DensArmor Plus Fireguard or 5/8"(15.9 mm)ToughRock Fireguard gypsum board applied vertically to framing.Base layer attached with 1"(25 mm) Type S-12 bugle head screws 12"(305 mm)o.c.Face layer attached with 1-5/8"(41 mm) Type S-12 bugle head screws spaced 12"(305 mm)o.c.Joints staggered.Insulation to completely fill stud cavity.(Load-bearing:80%of design load) 2-Hour Fire Rating Test Reference:UL U411,cUL U411 EXTERIOR Wall Thickness:5"(127 mm) -_7 _ -_— _ -_— _ -_7 _ -_ Weight per Sq.Ft.:11.0(54 kg/m2) I ] Exterior:Two layers 5/8"(15.9 mm)DensGlass Fireguard Sheathing applied vertically to min.2-1/2"(64 mm)corrosion resistant 25-gauge(18 mils)steel studs 24"(610 mm)o.c. Base layer attached with 1"(25 mm)Type S corrosion resistant bugle head screws 16" - _ - r_ - - - r_ (406 mm)o.c.Face layer attached with 1-5/8"(41 mm)Type S corrosion resistant bugle head screws spaced 8"(203 mm)o.c.Joints staggered. Interior:Two layers 5/8"(15.9 mm)DensArmor Plus Fireguard or 5/8"(15.9 mm) ToughRock Fireguard gypsum board applied vertically to framing.Base layer attached with 1"(25 mm)Type S bugle head screws 16"(406 mm)o.c.Face layer attached with 1-5/8"(41 mm)Type S bugle head screws spaced 16"(406 mm)o.c.in the field and along vertical edges and 12"(305 mm)o.c.to the floor and ceiling runners.Joints staggered.Batt or blanket insulation optional. 'Load restricted for Canadian applications—see UL Guide BXUV7. CAUTION:For product fire,safety and use information,go to gp.com/safetyinfo. 12 • For latest information and updates.Technical Service Hotline 1.800.225.6119 or www.gpgypsum.com DensGlass® Sheathing Atk Georgia-Pacific Gypsum Architectural Specifications Part 1 -General 1.0 Description Work in this section includes,but is not limited to:wall,ceiling and soffit sheathing. Related work specified elsewhere: Brick masonry Finish carpentry Joint sealers Stone Exterior Insulation and Finish Systems(EIFS) Light-gauge metal framing Cold-formed metal framing Siding Painting Rough carpentry 1.1 Submittals Product Data:Submit manufacturer's descriptive literature indicating material composition,thickness,sizes and fire resistance. 1.2 Quality Assurance Fire-resistance ratings:Where applicable,provide materials and construction that are identical to those of assemblies whose fire-resistance ratings are indicated. 1.3 Delivery,Storage and Handling Delivery: Deliver materials to the job site in manufacturer's original packaging,containers and bundles with manufacturer's brand name and identification intact and legible.Product also may be wrapped in temporary factory-applied plastic packaging(plastic wrap) that must be removed upon receipt.Reference GA801 for storage information.Failure to remove the plastic shipping covers and plastic wrap may result in entrapment of condensation or moisture,which may cause application problems. Storage and handling:Store flat on a level surface and handle materials to protect against contact with damp and wet surfaces, exposure to weather,breakage and damage to edges. Provide air circulation under covering and around stacks of materials. Part 2- Products 2.0 Sheathing Board Acceptable Products: 1/2"(12.7 mm)DensGlass®Sheathing; 5/8"(15.9 mm)DensGlass®Fireguard®Sheathing Size: DensGlass Sheathing: 1/2"(12.7mm)thick by 4'(1219 mm)by 8'(2438 mm),9'(2743 mm)or 10'(3048 mm)(1.9 lb.per square foot)(9.3 kg/m2); DensGlass Fireguard Sheathing:5/8"(15.9mm)thick x 4'(1219 mm)x 8'(2438 mm),9'(2743 mm)or 10' (3048 mm)(2.5 lb.per square foot)(12 kg/m2). Composition:Gypsum sheathing manufactured in accordance with ASTM C 1177 with fiberglass mats both sides and long edges, water-resistant treated core. Fire resistance: Noncombustible as described and tested in accordance with ASTM E 136 and CAN/ULC-S114. 1/2"or 5/8"(12.7 mm or 15.9 mm)DensGlass Sheathing:Flame spread 10,when tested in accordance with ASTM E 84 and CAN/ULC S-102.5/8"(15.9 mm)DensGlass Fireguard Sheathing is rated Type X as defined in ASTM C 1177 and can be used as a replacement to any other generic assembly utilizing a 5/8"(15.9 mm)Type X gypsum board(see GA-600 for numeric assemblies). DensGlass Fireguard Sheathing is UL classified,Type DGG,in UL designs G501,G520,G531,L501,L508,L532,L556,L591,N501, N502,N505,N602,P225,P227,P230,P235,P254,P259,P266,P302,P516,P517,P701,P710,P711,P713,P714,P717,P718,P719, P720,P722,P725,P728,P729,P730,P731,P732,P733,P734,P735,P738,P739,P740,P741,P742,P801,P811,P815,P819,P824, P825,P826,P827,P828,S728,S736,U017,U032,U040,U204,U207,U301,U302,U305,U309,U326,U329,U330,U332,U337, U338,U339,U341,U342,U351,U354,U355,U356,U357,U358,U360,U364,U369,U379,U411,U418,U420,U425,U434,U436, U439,U442,U449,U450,U460,U465,U467,U473,U475,U487,U494,U495,U502,U504,U505,U506,U510,U512,U531,U603, U617,U623,U626,U633,U640,U646,U647,U648,U649,U651,U652,U926,V415,V417,V419,V420,V421,V430,V432,V434, V435,V450,V473,V486,V487,V490,X508,X516,X517,X525,X526,X527,X528,X535,X602,X604 and ULC classified,Type DGG in ULC designs: EW10,EW17,U301,U302,W301,W404,W415,W442 and W465. DensGlass Fireguard Sheathing can be used in UL assemblies where the gypsum board is listed as Gypsum Board(Classified or Unclassified)for thicknesses up to 5/8"(15.9 mm). 2.1 Air-and Water-Resistive Barrier If required by local building code,#15,nonperforated,asphalt saturated felt complying with ASTM D 226,Type 1,synthetic building wraps complying with ASTM E 1677,or other water-resistive barrier system meeting local building code requirements. CAUTION:For product fire,safety and use information,go to gp.com/safetyinfo. For latest information and updates:Technical Service Hotline 1.800.225.6119 or www.gpgypsum.com • 13 AtGeorgia-Pacific DensGlass® Sheathing kGypsum 2.2 Accessories Joint tape:2"(51 mm)wide fiberglass mesh tape,see 3.2.A. Joint compound:ToughRock®setting-type joint compound,see 3.2.A. Nails,wood framing: 11-gauge galvanized roofing nails, 1-1/2"(38 mm)min. length for 1/2"(12.7 mm)DensGlass®Sheathing and 1-3/4"(45 mm)length for 5/8"(15.9 mm)DensGlass®Fireguard®Sheathing. Screws,metal framing: Bugle or wafer head,self-tapping,rust-resistant,fine thread for heavy-steel gauge. Bugle or wafer head, rust-resistant sharp point,fine thread for light-gauge metal framing or furring. Screws,wood framing: Rust-resistant,bugle or wafer head,coarse thread, 1-1/4"(32 mm)length sharp point for wood. Part 3— Execution 3.0 Preparation Examine subframing;verify that surface of framing and furring members to receive sheathing does not vary more than 1/8"(3 mm) from the placement of faces of adjacent members. 3.1 Sheathing Provide DensGlass Sheathing where indicated on drawings. Install sheathing in accordance with manufacturer's instructions and applicable instructions in GA-253 and ASTM C 1280. Install DensGlass Sheathing with GOLD side out. Use maximum lengths possible to minimize number of joints. Attach DensGlass Sheathing to wood framing with nails spaced 4"(102 mm)o.c.at perimeter for racking shear resistance;8"(203 mm) o.c.at perimeter where there are framing supports and where racking shear resistance is not required;and 8"(203 mm)o.c. along intermediate framing in field for both conditions.Unless specified otherwise,attach DensGlass Sheathing to metal framing with screws spaced 8"(203 mm)o.c.at perimeter where there are framing supports;and 8"(203 mm)o.c.along intermediate framing in field.A greater number of fasteners may be specified to obtain specific values. Drive fasteners to bear tight against and flush with surface of sheathing. Do not countersink. Locate fasteners minimum 3/8" (10 mm)from edges and ends of sheathing panels,tight against and flush with surface of sheathing. Water-Resistive Barrier: If a water-resistive barrier is required by the local building code,design professional,owner or cladding manufacturer over DensGlass Sheathing,one of the following procedures may be used. Consult building code or design authority for proper application selection.Follow manufacturer's installation recommendations. A. Entire exterior face of gypsum sheathing covered with an asphalt impregnated felt or synthetic fiber wrap such as Tyvek® Commercial Wrap,or equal. B. Liquid applied barriers such as Sto Guard®as manufactured by Sto Corp.,Dryvit's Backstop®NT,Prosoco R-GUARDTM,or equal. C. Self adhering membranes. 3.2 Painted Ceilings and Soffits Soffits must be dried in and protected from the elements during and after installation. A. Apply fiberglass mesh joint tape over joints and embed in setting-type joint compound specified.Skim coat surface with setting-type joint compound for smooth finish.Prime and paint with exterior grade,high quality paint. B. Apply EIFS with or without insulation; install as recommended by manufacturer. CAUTION:For product fire,safety and use information,go to gp.com/safetyinfo. 14 • For latest information and updates.Technical Service Hotline 1.800.225.6119 or www.gpgypsum.com DensGlass® Sheathing Atk Georgia-Pacific Gypsum Limitations DensGlass®Sheathing is resistant to normal weather conditions,but it is not intended for immersion in water.Cascading roof/ floor water should be directed away from the sheathing until appropriate drainage is installed. Avoid any condition that will create moisture in the air and condensation on the exterior walls during periods when the exterior temperature is lower than the interior.The use of forced air heaters creates volumes of water vapor which,when not properly vented,can condense on building materials.The use of these heaters and any resulting damage is not the responsibility of Georgia-Pacific Gypsum.Consult heater manufacturer for proper use and ventilation.Vapor barrier may also restrict ventilation. When DensGlass Sheathing panels are used in slanted wall applications,that portion of the wall must be temporarily protected from the elements by the use of a water-resistant barrier prior to application of the cladding. Do not allow water to pond or settle on sheathing.Also,exposed wall ends such as those that may be found in parapets must be covered to prevent water from infiltrating the cavity. Georgia-Pacific Gypsum does not warrant and is not responsible or liable for the performance of the cladding or exterior systems applied over DensGlass Sheathing.The suitability and compatibility of any system is the responsibility of the system manufacturer or design authority. Do not laminate DensGlass Sheathing to masonry surfaces; use furring strips or framing. DensGlass Sheathing is not intended for roof applications.For roof applications,consult our DensDeck®Roof Board brochure. DensGlass Sheathing is not intended for interior or exterior tile applications.For interior tile applications,consult our DensShield® Tile Backer brochure. DensGlass Sheathing should not be used in lieu of plywood where required. Do not apply DensGlass Sheathing below grade. For all installations,design details such as fasteners,sealants and control joints per system specifications must be properly installed.Openings and penetrations must be properly flashed and sealed. Failure to do so will void the warranty. Do not use DensGlass Sheathing as a base for nailing or mechanical fastening.Fasteners should be flush to the face of the board,not countersunk. COMMONLY USED METRIC CONVERSIONS Gypsum Board Thickness Framing Spacing 1/4 in.—6 mm 16 in.—406 mm 1/2 in.—12.7 mm 24in.-610mm 5/8 in.—15.9 mm Fastener Spacing 1 in.—25.4 mm 2 in.—51 mm Gypsum Board Width 2.5 in.—64 mm 2ft.-610mm 7in.-178mm 4ft.-1219mm 8in.-203mm 32 in.—813 mm 12 in.—305 mm Gypsum Board Length 16 in.—406 mm 4ft.-1219mm 24in.-610mm 5 ft.—1524 mm Temperature 8 ft.—2438 mm 40°F—5°C 9 ft.—2743 mm 50°F—10°C 10 ft.—3048 mm 125°F—52°C 12 ft.—3658 mm CAUTION:For product fire,safety and use information,go to gp.com/safetyinfo. For latest information and updates:Technical Service Hotline 1.800.225.6119 or www.gpgypsum.com • 15 The Dens- Brand of High-Performance Gypsum Products from Georgia-Pacific DensGlass®Sheathing The original and universal standard of exterior gypsum sheathing offers superior weather resistance,with a 12-month weather exposure limited warranty.Look for the familiar GOLD color. DensShield®Tile Backer Acrylic-coated tile backer stops moisture at the surface.Lightweight and strong,built for speed on the job site.IBC/IRC Code Compliant.GREENGUARD listed for microbial resistance. DensDeck®Roof Boards Fiberglass mat roof board used as the ideal thermal barrier and cover board to improve resistance to wind uplift,hail,foot traffic,fire,moisture and mold in a broad range of commercial roofing applications.Look for green DensDeck Prime and DensDeck DuraGuard,too. DensGlass®Shaftliner Specially-designed panels for moisture-prone vertical or horizontal shafts,interior stairwells and area separation wall assemblies.12-month weather exposure limited warranty. GREENGUARD listed for microbial resistance. DensArmor Plus°High-Performance Interior Panel High-performance interior panel accelerates scheduling because it can be installed before the building is dried-in.12-month weather exposure limited warranty.GREENGUARD Indoor Air Quality Certified®GREENGUARD Children&SchoolsSM Certified and CHPSTm listed for low emissions.GREENGUARD listed for microbial resistance. DensArmor Plus°Abuse-Resistant Interior Panel Same benefits as DensArmor Plus®High-Performance Interior Panel with added resistance to scuffs,abrasions and surface indentations.Ideal for healthcare facilities and schools. GREENGUARD Indoor Air Quality Certified®GREENGUARD Children&SchoolsSM Certified and CHPSTm listed for low emissions.GREENGUARD listed for microbial resistance. DensArmor Plus°Impact-Resistant Interior Panel Even greater durability with an embedded impact-resistant mesh for the ultimate resistance in high traffic areas.Ideal for healthcare facilities,schools and correctional institutions. GREENGUARD Indoor Air Quality Certified®GREENGUARD Children&SchoolsSM Certified and CHPSTm listed for low emissions.GREENGUARD listed for microbial resistance. TRADEMARKS— a registered trademark of and installation of the product Unless otherwise noted, BASF.LEED,USGBC and may cause skin,eye and all trademarks are owned related logo are trademarks respiratory tract irritation. by or licensed to Georgia- owned by the U.S.Green Avoid breathing dust and Pacific Gypsum LLC.The Building Council and are used minimize contact with skin GP Georgia-Pacific GREENGUARD INDOOR AIR by permission.Collaborative for and eyes.Wear long sleeve Gypsum QUALITY CERTIFIED Mark and High Performance Schools and shirts,long pants and eye the GREENGUARD Children& CHPS are trademarks owned protection.Always maintain U.S.A. Georgia-Pacific Gypsum LLC Schools Mark are registered by Collaborative for High adequate ventilation.Use a CANADA Georgia-Pacific Canada,ULC certification marks used Performance Schools Inc. dust mask or NIOSH/MSHA under license through the WARRANTIES,REMEDIES approved respirator as SALES INFORMATION AND ORDER PLACEMENT GREENGUARD Environmental AND TERMS OF SALE— appropriate in dusty or poorly U.S.A. Midwest:1-800-876-4746 West: 1-800-824-7503 Institute.The color PINK and ventilated areas. South: 1-800-327-2344 Northeast:1-800-947-4497 Owens Corning are trademarks For current warranty of Owens Corning.TYVEK is information for this FIRE SAFETY CAUTION— CANADA Canada Toll Free: 1-800-387-6823Quebec Toll Free: 1-800-361-0486 a registered trademark of product,please go to Passing a fire test in a DuPont.TYPAR and www•gpgypsum.com and controlled laboratory setting TECHNICAL HOTLINE U.S.A.and Canada:1-800-225-6119 METROWRAP are registered select the product for warranty and/or certifying or labeling of Fiberweb. information.All sales of this a product as having a one- trademarks" STO GUARD is a registered product by Georgia-Pacific hour,two-hour,or any other 44 "`,� are subject to our Terms fire resistance or protection trademark of Sto Corp. of Sale available at rating and,therefore,as BACKSTOP is a registered www.gpgypsum.com. acceptable for use in certain 4,em trademark of Dryvit.R-GUARD is a registered trademark of UPDATES AND CURRENT fire rated assemblies/systems, Some of our products have been certified by Scientific Certification Prosoco.EXOAIR is a trademark INFORMATION—The does not mean that either a Systems(SCSI.SCS is an internationally recognized third-party particular assembly/system of Tremco Incorporated. information in this evaluation,testingof the on.Its program incorporating the product,or a wide cross-section of the economy,including manufacturing and AIR-BLOC is a registered trade- document may change without any given piece of the product retailing,consumer products,the energy industry,and the home mark of The Henry Company. notice.Visit our website at itself,willnecessarilyprovide 9pgYP improvement and construction sectors.For details on specific BARRISEAL is a trademark www.gpgypsum.com for Georgia-Pacific Gypsum products and plants,please contact our one-hour fire resistance,two- Technical Hotline at 1-800-225-6119. of Carlisle.DELTA DRY is a updates and current information. hour fire resistance,or any trademark of Ewald Dorken CAUTION:For product fire, other specified fire resistance A.G.PERM-A-BARRIER is a safety and use information, or protection in an actual fire. trademark of W.R.Grace&Co. go to gp.com/safetyinfo or In the event of an actual fire, GE is a registered trademark call 1-800-225-6119. you should immediately take of General Electric Company. any and all actions necessary Dow Corning is a registered HANDLING AND USE— for your safety and the safety trademark of Dow Corning CAUTION:This product of others without regard for Corporation.Percora is a contains fiberglass facings any fire rating of any product registered trademark of which may cause skin or assembly/system. Percora Corporation.BASF is irritation.Dust and fibers produced during the handling ©2010 Georgia-Pacific Gypsum LLC.All rights reserved.Printed in the U.S.A.GEO 1/10.GP Lit.Item 4621543.