ICC EVALUATION Most Widely Accepted and Trusted EVALUATION SERVICE me &Rwfh (e Innovation L- RESEARCH LABS ICC-ES Evaluation Report ESR-2053 ICC-ES I (800)423-6587 I (562) 699-0543 I www.icc-es.org Reissued 07/2018 This report is subject to renewal 07/2020. DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION SECTION: 07 30 05—ROOFING FELT AND UNDERLAYMENT REPORT HOLDER: GAF EVALUATION SUBJECT: VERSASHIELD® FIRE-RESISTANT ROOF DECK PROTECTION AND VERSASHIELDTM UNDERLAYMENT ICC ICC ICC PMG LISTED anw "2014 Recipient of Prestigious Western States Seismic Policy Council inn (WSSPC)Award in Excellence" A Subsidiary of coo CO ae ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. ANSI There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this ACCREDITED report, or as to anyproduct covered bythe report. ISO/IEC 17065 p p Product CeNfication Body #1000 Copyright© 2018 ICC Evaluation Service, LLC. All rights reserved. ICC ESEVALUATION SERVICE • L,��,,,,,� Most Widely Accepted and Trusted ICC-ES Evaluation Report ESR-2053 Reissued July 2018 This report is subject to renewal July 2020. www.icc-es.org I (800) 423-6587 I (562) 699-0543 A Subsidiary of the International Code Council° DIVISION: 07 00 00—THERMAL AND MOISTURE 4.0 INSTALLATION PROTECTION Section: 07 30 05—Roofing Felt and Underlayment 4.1 General: VersaShield® Fire-Resistant Roof Deck Protection is REPORT HOLDER: installed in accordance with the requirements of the applicable code, the manufacturer's published installation GAF instructions and this report. The manufacturer's published installation instructions are to be available at the jobsite EVALUATION SUBJECT: during the installation. VERSASHIELD® FIRE-RESISTANT ROOF DECK VersaShield® Fire-Resistant Roof Deck Protection is PROTECTION AND VERSASHIELDTM UNDERLAYMENT limited to use over spaced or solid sheathing, or over existing asphalt shingles, wood shakes or wood shingles 1.0 EVALUATION SCOPE installed on spaced or solid sheathing. Prior to application of the underlayment, the deck surface is to be free of dust Compliance with the following codes: and dirt, loose nails and other protrusions. Damaged • 2012, 2009 and 2006 International Building Code°(IBC) sheathing is to be replaced. The underlayment is applied at • 2012, 2009 and 2006 International Residential Code® right angles to the slope of the roof, beginning at the low (IRC) point of the roof, and is laid with minimum 2-inch (51 mm) horizontal and 6-inch (152 mm) vertical lapped joints. It is • 2013 Abu Dhabi International Building Code(ADIBC)t attached with a sufficient number of nails, having tin caps 'The ADIBC is based on the 2009 IBC.2009 IBC code sections referenced or 1-inch-diameter (25.4 mm) plastic caps, to hold the in this report are the same sections in the ADIBC. underlayment in place until the roof covering is applied, Properties evaluated: except in areas subject to high winds where the • Physical properties underlayment fastening must comply with the high wind attachment requirements specified in Section 1507 of the • Fire classification 2012 IBC or Section R905 of the 2012 IRC. The 2.0 USES underlayment may be bent to a minimum 1/2-inch ® (12.7 mm) radius, but is not to be creased. At junctions VersaShield® Fire-Resistant Roof Deck Protection between the roof deck and vertical surfaces, the (previously known as VersaShield® Underlayment) is used underlayment is installed a minimum of 3 inches (76 mm) as an alternative to ASTM D226, Type I or Type II, roofing up the vertical surface. underlayment specified in Chapter 15 of the IBC and Chapter 9 of the IRC. In areas of the roof required to have an ice barrier under When installed in accordance with Section 4.2.1 of this Chapter 15 of the IBC or Chapter 9 of the IRC, a self report, VersaShield® Fire-Resistant Roof Deck Protection adhesive polymer bitumen sheet, complying with ASTM can also be used over existing wood shakes or shingles as D1970 or the ICC ES Acceptance Criteria for Self adhered an alternative to the covering materials specified in Section Underlayments for Use as Ice Barriers (AC48), is to be 1510.4 of the IBC or Section R907.4 of the IRC. applied. The underlayment is to be applied over the solid substrate in sufficient courses so that the underlayment VersaShield® Fire-Resistant Roof Deck Protection is also extends up the roof a distance equal to the distance inside used as a component of classified roofing assemblies as the exterior wall line of the building that is specified by the described in Section 4.3, when installed in accordance with applicable code. The underlayment, applied in the field of this report. the roof, is to completely overlap the ice barrier (severe 3.0 DESCRIPTION climate underlayment) protection a minimum of 2 inches (51 mm). VersaShield® Fire-Resistant Roof Deck Protection is a resin-bound chopped-glass-fiber substrate, coated on Installation of the roof covering can proceed immediately both sides with a mineral-filled aqueous coating. The following the underlayment application. The underlayment underlayment has a weight of 15 pounds per 100 square is to be covered by a roof covering within the time set forth feet(0.73 kg/m2), and is supplied in rolls. in the manufacturer's published installation instructions. ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed,nor are they to be construed ANSI as an endorsement of the subject of the report or a recommendation for its use.There is no warranty by ICC Evaluation Service,LLC,express or implied,as Mat to any finding or other matter in this report,or as to any product covered by the report. LEea Copyright©2018 ICC Evaluation Service,LLC.All rights reserved. Page 1 of 4 ESR-2053 I Most Widely Accepted and Trusted Page 2 of 4 4.2 Reroofing: 5.0 CONDITIONS OF USE The existing roof must be inspected in accordance with The VersaShield® Fire-Resistant Roof Deck Protection Section 1510 of the IBC or Section R907 of the IRC. The described in this report, complies with, or is a suitable new roof covering is installed over the VersaShield® alternative to what is specified in, those codes listed in Fire-Resistant Roof Deck Protection in accordance with the Section 1.0 of this report, subject to the following roof covering manufacturer's published installation conditions: instructions. The new roof covering must be recognized in 5.1 Installation must comply with this report; the a current ICC-ES evaluation report, and, when applicable, manufacturer's published installation instructions and the evaluation report must address installation over wood the applicable code. In the event of a conflict between shake, wood shingle or asphalt shingle roofs. the manufacturer's published installation instructions 4.2.1 Existing Wood Shakes or Shingles: Where the and this report, this report governs. application of a new roof covering over wood shingle or 5.2 Installation is limited to roofs with a minimum slope of shake roofs creates a combustible concealed space, VersaShield® Fire-Resistant Roof Deck Protection can be 2:12 (16.67 percent slope) or to the minimum slope used as an alternative to the covering materials specified required for the roof covering in accordance with the in Section 1510.4 of the IBC or Section R907.4 of the IRC. applicable code,whichever is greater. The underlayment covers the entire existing wood roof. 5.3 Installation is limited to use with roof coverings that do Battens used for the new roof covering system are not involve hot asphalt or coal-tar pitch. installed over the underlayment. The underlayment may be 5.4 Installation is limited to use with approved roof placed under or over counterbattens, spaced a maximum coverings that are mechanically fastened through the of 24 inches (610 mm) on center. The underlayment is underlayment to the sheathing or rafters. fastened to the counterbattens with a sufficient number of nails, having tin caps or 1-inch-diameter (25.4 mm) plastic 5.5 Installation is limited to roofs with ventilated attic caps, to hold the underlayment in place until the spaces in accordance with the requirements of the horizontal battens and roof covering are applied. When applicable code. counterbattens are installed over the underlayment or 5.6 VersaShield® Fire-Resistant Roof Deck Protection is when counterbattens are not used, the underlayment is produced in Conover, North Carolina, under a quality fastened directly to the existing roof covering in the same control program with inspections by ICC-ES. manner. 4.2.2 Existing Asphalt Shingles: When installed over 6.0 EVIDENCE SUBMITTED existing asphalt shingles, the underlayment is applied over Data in accordance with the ICC-ES Acceptance Criteria the existing roof covering and fastened through the for Nonasphaltic Fiberglass-based Roof Underlayment shingles to the sheathing with a sufficient number of nails, (AC160), dated January 2000 (editorially revised February having tin caps or 1-inch-diameter(25.4 mm) plastic caps, 2014). to hold the underlayment in place until the roof covering is 7.0 IDENTIFICATION applied. 7.1 Each roll of underlayment bears a label indicating the 4.3 Roof Classification: GAF name and address, the plant identification, the When installed in accordance with this report, product name, the roll number, and the evaluation VersaShield® Fire-Resistant Roof Deck Protection can be report number(ESR-2053). used as an alternative to Exception 2 to Section 1505.2 of 7.2 The report holder's contact information is the the 2012 and 2009 IBC, the Exception to Sections 1505.2 following: and 1505.3 of the 2006 IBC, and Section R902.1 of the IRC; or any roofing assembly having a Class A, B or C roof GAF classification, without reducing the roof classification. 1 CAMPUS DRIVE When installed in accordance with Section 4.1 and Table 1 PARSIPPANY, NEW JERSEY 07054 of this report, roofing assemblies incorporating (973)628-3000 VersaShield® Fire-Resistant Roof Deck Protection have www.gaf.com the roof classification specified in Table 1. The roof coverings must be recognized in a current ICC-ES evaluation report as shown in Table 2. ESR-2053 I Most Widely Accepted and Trusted Page 3 of 4 TABLE 1—ROOF CLASSIFICATION OF ASSEMBLIES INCORPORATING VERSASHIELD°FIRE-RESISTANT ROOF DECK PROTECTION ROOF COVERING2 SUBSTRATE UNDERLAYMENT1 ROOF MAXIMUM CLASSIFICATION SLOPE Class A asphalt glass fiber shingle 15/32-inch plywood One layer VersaShield® A Unlimited Stone coated,steel,direct to deck, 95/32 inch plywood or 0.013-inch thickness(0.330 mm), spaced sheathing One layer VersaShield® A Unlimited shingles or panels 15/32 inch plywood or One layer VersaShield®,and Steel direct to deck,0.013-inch spaced sheathing one layer Type 30 asphalt A Unlimited thickness(0.330 mm),shingles or saturated organic felt panels 15/32-inch plywood or One layer VersaShield® B Unlimited spaced sheathing 15/32-inch plywood or One layer VersaShield® A Unlimited spaced sheathing Steel over battens,0.013-inch Existing wood shakes or thickness(0.330 mm),shingles or shingles installed over Two layers VersaShield® A Unlimited panels spaced or solid sheathing Existing wood shakes or shingles installed over One layer VersaShield® B Unlimited spaced or solid sheathing Steel,0.016-inch thickness(0.406 15/32-inch plywood or mm),panels or standing seam spaced sheathing One layer VersaShield® A Unlimited system 15/32-inch plywood or One layer VersaShield®,and spaced sheathing one layer Type 30 asphalt A Unlimited saturated organic felt Existing wood shakes or shingles installed over Two layers of VersaShield® A Unlimited Copper,0.016-inch thickness(0.406 spaced or solid sheathing mm),shingles or panels 15/32-inch plywood or spaced sheathing One layer VersaShield® B Unlimited Existing wood shakes or shingles installed over One layer of VersaShield° B Unlimited spaced or solid sheathing 15/32 inch plywood or Two layers VersaShield® A Unlimited spaced sheathing Aluminum,0.018-inch(0.457 mm), 15/32-inch plywood or One layer VersaShield® B Unlimited shingles,panels,or standing seam spaced sheathing system Existing wood shakes or shingles installed over One layer VersaShield® B Unlimited spaced or solid sheathing 15/32-inch plywood Two layers VersaShield® A 11/2:12 TPO,CSM,CPA,EPDM,cap sheet, 15/32-inch plywood, or modified bitumen single-ply insulation Two layers VersaShield® A 11/2:12 membranes 15/32-inch plywood One layer VersaShield® B 11/2:12 15/32-inch plywood Two layers VersaShield® A 2:12 PVC single-ply membrane 15/32 inch plywood, Two layers VersaShield® A 11/2:12 insulation 15/32-inch plywood One layer VersaShield® B 11/2:12 For SI: 1 inch=25.4 mm. 1Underlayment must be installed in accordance with Section 4.0 of this report. 2Roof coverings must be recognized in a current ICC-ES evaluation report.The roof covering must comply with the Class A or B flame-spread requirements of UL790(ASTM E108),as applicable to the systems defined in this table. ESR-2053 I Most Widely Accepted and Trusted Page 4 of 4 TABLE 2—EVALUATION REPORT CROSS-REFERENCE COMPANY ICC-ES EVALUATION RECOGNIZED PRODUCT REPORT NUMBER Carlisle Syntec ESR-1463 EPDM,PVCand TPO Single-Ply Membranes Delta Building Products, Ltd. ESR-1790 Aluminum and Steel Roofing Shingles and Panels Decra Roofing Systems, Inc. ESR-1754 Decra Villa Tile,Decra Shake XDTM and Decra Shingle XDTM Steel Roofing Panels Decra Roofing Systems, Inc. ESR-2901 Steel Roofing Panels: Decra Tile, Decra Shake, Decra Shingle Plus Gerard,Allmet,Storm Loc,Energy Loc,Armor, Eco Loc, Rof Gerard Roofing Technologies ESR-1188 Loc,Storm Loc,and Stormtile Brands of Guardian,Granite Ridge,Diplomat and Diplomat Plus Steel Roofing Panels Steel Roofing Panels:Tile;Shake;Canyon Shake; Barrel Gerard Roofing Technologies ESR-1491 Vault;NB Tile in the following brands:Allmet,Armor,Eco Loc, Energy Loc,Gerard,Roof Loc,Stone Loc,Storm Loc, Stormtile Firestone Building Products Company, LLC ESR-2831 Firestone UltraPlyTM TPO and TPO XR Singly Ply Roofing Membranes Ideal Roofing Company Ltd. ESR-3101 Wakefield Bridge(26 gage)Steel Panels and Wakefield Bridge(29 gage)Steel Panels Ideal Roofing Company Ltd. ESR-3100 HF-16 and HF-20.25 Roof Panels DaVinci Roofscapes, LLC ESR-2119 DaVinci Slate,DaVinci Shake,Bellaforte Shake and Bellaforte Slate Roof Shingles Feroof Co., Ltd. ESR-3331 Steel Roofing Panels:Veneto I, Veneto II, Rio,Rio EZ, Diva,Wood,Zissen and Slate Ensoltis Green Hybrid Roofing LLC ESR-2904 Ensoltis Savanna S Roof Tile Custom-Bilt Metals ESR-2048 Custom-Bilt Standing Seam Metal Roof:CB-150 and SL-1750 2001 Company, Inc.,dba Kelly Company-2001 Inc. ESR-3185 2001 Company Inc. EPDM, PVC and TPO Single-Ply Roofing Membranes Roser Co.,Ltd ESR-1763 Roser Steel Roofing Panels:Spany, Roser Bond, Rowood, Tuscany Tile and Stonewood Shake Berridge Manufacturing Company ESR-3486 Berridge Cee-Lock and Zee-Lock Standing Seam Roof Panels 1The aluminum panels are limited to Class B roof covering assemblies.