Loading...
HomeMy WebLinkAboutFile Documents.743 Cemetery Ln.0011.2018 (69).ARBK IRRIGATION LEGEND 3941s SLEEVES: CLASS 200 PVC O e ■ POP-UP SPRAY SPRINKLER: RAIN BIRD RD1806-S-P30 W/U SERIES 8 NOZZLE PRESSURE: 30 PSI RADIUS: 8 FEET MAINLINE PIPE: CLASS 200 PVC FLOW (GPM): Q-0.26 H-0.52 F-1.05 1 1/4-INCH UNLESS OTHERWISE INDICATED HINES INC LATERAL PIPE TO SPRINKLERS: CLASS 200 PVC a a a POP-UP SPRAY SPRINKLER: RAIN BIRD RD1806-S-P3D W/U SERIES 10 NOZZLE .4(101 1-INCH UNLESS OTHERWISE INDICATED PRESSURE: 30 PSI RADIUS: 10 FEET FLOW (GPM): Q-0.41 H-0.82 F-1.64 VICES - - LATERAL PIPE HEADER TO INLINE DRIP: CLASS 200 PVC SITEW.DRAKER MANAGEMTE ENT FORT 1-INCH UNLESS OTHERWISE NOTED823 W. COL RADO 80264 FORT e e A POP-UP SPRAY SPRINKLER: RAIN BIRD RD1806-S-P30 W/U SERIES 12 NOZZLE COLLINS,COLORAD080526 PRESSURE: 30 PSI RADIUS: 12 FEET Telephone:970.282.1800 J.//4 INLINE DRIP TUBING: NETAFIM TLCV26-12 FLOW (GPM): Q-0.65 H-1.30 F-2.60 Web:www.hinesinc.com (J(l LATERAL PIPE TO TREE/SHRUB EMITTERS IN GRASS: 80 PSI RATED POLYETHYLENE (3/4-INCH SIZE, ROUTING IS DIAGRAMMATIC) e e • POP-UP SPRAY SPRINKLER: RAIN BIRD RD1806-S-P30 W/U SERIES 15 NOZZLE PRESSURE: 30 PSI RADIUS: 15 FEET st UNCONNECTED PIPE CROSSING FLOW (GPM): Q-0.92 H-1.85 F-3.70 I- POINT-OF-CONNECTION ASSEMBLY . e•POP-UP SPRAY SPRINKLER: RAIN BIRD RD1806-S-P30 W/MPR SERIES I BACKFLOW PREVENTION ASSEMBLY: FEBCO 825-Y 15SST OR 15EST NOZZLE, PRESSURE: 30 PSI PATTERN: 4 X 15 FEET FLOW (GPM): EST-0.61 SST-1.21 m MASTER VALVE ASSEMBLY: RAIN BIRD PESB ��INDICATES CONTROLLER AND STATION NUMBER ❑F FLOW SENSOR ASSEMBLY: RAINBIRD FS100B Al r-INDICATES LATERAL DISCHARGE (GPM) N ISOLATION GATE VALVE ASSEMBLY: MATCO 514 1^ 1.00 INDICATES VALVE SIZE (INCHES) e QUICK COUPLING VALVE ASSEMBLY:RAINBIRD SRC 30PSI --",----- LLJ INDICATES APPLICATION RATE (IN/HR) iiii REMOTE CONTROL VALVE ASSEMBLY FOR SPRINKLER LATERALS �.,___INDICATES DESIGN PRESSURE (PSI) CC HUNTER ICV (SIZED PER PLAN) AO IRRIGATION CONTROLLER UNIT WITH WEATHERSTATION ® REMOTE CONTROL DRIP VALVE ASSEMBLY: RAINBIRD XCZ-PRB-100-COM CONTROLLER A:RAINBIRD ESP-LXMEF: 5 Stations CONTROLLER B:RAINBIRD ESP-LXMEF: 5 Stations <VLr FLUSH CAP ASSEMBLY CONTROL WIRES IN CONDUIT OR WITH WARNING TAPE ' 1 ULLJ H I INSTALLATION GENERAL NOTES CC czt 1. THE SYSTEM DESIGN ASSUMES A MINIMUM DYNAMIC PRESSURE FOR THE COMPLETION OF THE PROJECT: IRRIGATION SYSTEM OF 105 PSI (PER CITY ENGINEER), AT A MAXIMUM DISCHARGE OF 12 GPM AT THE 3/4 -INCH IRRIGATION A. TWO (2) OPERATING KEYS FOR EACH TYPE OF MANUALLY w LLJ POINT-OF-CONNECTION (POC). VERIFY PRESSURE AND FLOW ON SITE OPERATED VALVES. PRIOR TO CONSTRUCTION. Z 2. READ THOROUGHLY AND BECOME FAMILIAR WITH THE SPECIFICATIONS AND 7. SELECT NOZZLES FOR SPRAY AND ROTARY SPRINKLERS WITH ARCS WHICH Q INSTALLATION DETAILS FOR THIS AND RELATED WORK PRIOR TO PROVIDE COMPLETE AND ADEQUATE COVERAGE WITH MINIMUM OVERSPRAY ' 1 CONSTRUCTION. FOR THE SITE CONDITIONS. CAREFULLY ADJUST THE RADIUS OF THROW J U AND ARC OF COVERAGE OF EACH ROTARY SPRINKLER TO PROVIDE THE 3. COORDINATE UTILITY LOCATES ("CALL BEFORE YOU DIG") OF BEST PERFORMANCE. `yCip UNDERGROUND UTILITIES PRIOR TO CONSTRUCTION. 8. THE IRRIGATION CONTRACTOR IS RESPONSIBLE FOR THE INSTALLATION OF / ❑ 4. DO NOT PROCEED WITH THE INSTALLATION OF THE IRRIGATION SYSTEM IRRIGATION SLEEVING. SLEEVES ARE REQUIRED FOR BOTH PIPING AND CC WHEN IT IS OBVIOUS IN THE FIELD THAT OBSTRUCTIONS OR GRADE ELECTRICAL WIRING AT EACH HARDSCAPE CROSSING. COORDINATE DIFFERENCES EXIST THAT MIGHT NOT HAVE BEEN CONSIDERED IN THE INSTALLATION OF SLEEVING WITH OTHER TRADES. ANY PIPE OR WIRE ENGINEERING. IF DISCREPANCIES IN CONSTRUCTION DETAILS, LEGEND, WHICH PASSES BENEATH EXISTING HARDSCAPE WHERE SLEEVING WAS NOT LLJ NOTES, OR SPECIFICATIONS ARE DISCOVERED, BRING ALL SUCH INSTALLED WILL REQUIRE HORIZONTAL BORING BY THE IRRIGATION 1 OBSTRUCTIONS OR DISCREPANCIES TO THE ATTENTION OF THE OWNER'S CONTRACTOR. PIPE SLEEVES SHALL BE SIZED TWICE THE NOMINAL SIZE REPRESENTATIVE. OF THE PIPE PASSING THROUGH. W 5. THE DRAWINGS ARE DIAGRAMMATIC. THEREFORE, THE FOLLOWING SHOULD 9. INSTALL ALL ELECTRICAL POWER TO THE IRRIGATION CONTROL SYSTEM IN C BE NOTED: ACCORDANCE WITH THE NATIONAL ELECTRIC CODE AND ALL APPLICABLE L> LOCAL ELECTRIC UTILITY CODES. A. ALTHOUGH IRRIGATION COMPONENTS MAY BE SHOWN LLJ 10. THE FOLLOWING SHOULD BE NOTED REGARDING PIPE SIZING: IF A OUTSIDE PLANTING AREAS FOR CLARITY, INSTALL SECTION OF UNSIZED PIPE IS LOCATED BETWEEN THE IDENTICALLY SIZED IRRIGATION PIPE AND WIRING IN LANDSCAPED AREAS /� WHENEVER POSSIBLE. SECTIONS, THE UNSIZED PIPE IS THE SAME NOMINAL SIZE AS THE TWO \` N SIZED SECTIONS. THE UNSIZED PIPE SHOULD NOT BE CONFUSED WITHCD B. TREE AND SHRUB LOCATIONS AS SHOWN ON LANDSCAPE THE DEFAULT PIPE SIZE NOTED IN THE LEGEND. LS n J U PLANS TAKE PRECEDENCE OVER IRRIGATION EQUIPMENT LOCATIONS. 11. INSTALL TWO (2) #14 AWG CONTROL WIRES ON STANDARD WIRE SYSTEMS, icr 03 AVOID CONFLICTS BETWEEN THE IRRIGATION SYSTEM, PLANTING MATERIALS, AND ARCHITECTURAL FEATURES. FOR USE AS SPARES. INSTALL SPARE WIRES FROM CONTROLLER ❑ Q LOCATION TO EACH DEAD-END OF MAINLINE. COIL 3 FEET OF WIRE IN C. USE ONLY STANDARD TEES AND ELBOW FITTINGS. USE OF TEES IN VALVE BOX. CDCC LLi THE BULLNOSE CONFIGURATION, OR USE OF CROSS TYPE FITTINGS IS NOT ALLOWED. 12. ALL IRRIGATION WORK PERFORMED UNDER PROTECTED TREES REQUIRES Reviewed and Approved for \ O sitc Q HAND GRUBBING NO DEEPER THAN FOUR (4) INCHES. 6. PROVIDE THE FOLLOWING COMPONENTS TO THE OWNER PRIOR TO THE Water Efficient Landscaping 0 6) (Y] � NX0 Standards rickma 04/02/2019 w 0 20 m ULi q - toa as N - i � 5CL 0 CONSTRUCTION NOTES CITY OF ASPEN GENERAL NOTES Designed: JB OTHE IRRIGATION SYSTEM POINT-OF-CONNECTION (POC) SHALL BE 1. APPLICANT IS RESPONSIBLE FOR ASSURING OPERATING PRESSURE Drafted: MR,JB DOWNSTREAM OF THE IRRIGATION WATER TAP AND METER INSTALLED BY AT EACH EMISSION DEVICE IS WITHIN THE MANUFACTURER'S Reviewed: MR OTHERS AT THE APPROXIMATE LOCATION SHOWN. INSTALL BACKFLOW RECOMMENDED PRESSURE RANGE FOR OPTIMAL PERFORMANCE. IF Date Issued: PREVENTION UNIT AND MASTER VALVE ASSEMBLY AS INDICATED, SAME PRESSURE IS NOT WITHIN THE PREFERRED RANGE,ACTIONS 03.01.2019 SIZE AS POC. VERIFY EXACT LOCATION OF POC WITH OWNER'S DESCRIBED IN SECTION 6.1.10 OF THE WATER EFFICIENT REPRESENTATIVE. LANDSCAPING STANDARDS MUST BE TAKEN. Revision Tide Date 2. SPRINKLERS WITHIN INDIVIDUAL IRRIGATION ZONE SHALL HAVE O WALL MOUNT THE IRRIGATION CONTROLLER INSIDE THE GARAGE AT THE MATCHED PRECIPITATION RATES, UNLESS OTHERWISE DIRECTED BY 1 Revision 1 03.01.2019 APPROXIMATE LOCATION SHOWN. COORDINATE ELECTRICAL POWER TO THE MANUFACTURER'S RECOMMENDATIONS. 2 THE CONTROLLER WITH THE OWNER'S REPRESENTATIVE. CARE SHOULD 3. ENSURE THERE IS HIGHEST POSSIBLE DISTRIBUTION UNIFORMITY, BE TAKEN TO INSTALL THE IRRIGATION CONTROLLER IN A LOCATION THAT AND HEAD-TO-HEAD COVERAGE. 3 IS ACCESSIBLE FOR MAINTENANCE, AND SCREENED FROM VIEW EITHER 4. AN IRRIGATION MAINTENANCE SCHEDULE AND IRRIGATION 4 BEHIND ENTRY WALLS, NEXT TO BUILDINGS, OR BEHIND PLANT MATERIAL. MANAGEMENT PLAN IS REQUIRED AS DESCRIBED IN SECTION 6.7 I HAVE COMPLIED WITH THE CRITERIA OF THE WATER EFFICIENT LANDSCAPING STANDARDS AND APPLIED THEM ACCORDINGLY FINAL LOCATION TO BE APPROVED BY OWNER'S REPRESENTATIVE. THROUGH 6.9 OF THE STANDARDS. FOR THE EFFICIENT USE OF WATER IN THE IRRIGATION DESIGN PLAN s a O IRRIGATION SHOWN OUT OF LANDSCAPED AREA FOR CLARITY ONLY. ENSURE THE FOLLOWING: INSTALL IRRIGATION COMPONENTS WITHIN LANDSCAPED AREA. /I f�' v 1. TURF GRASS SPRINKLER HEADS SHALL HAVE A DISTRIBUTION Ir//!l,/'{IW'", V/!L(Il{/�Q/yl�, 0 MAINLINE AND LATERAL LINES ARE SHOWN IN SAME SLEEVE FOR UNIFORMITY OF 0.65 OF HIGHER USING THE PROTOCOL DEFINED IN CLARITY ONLY. MAINLINE, CONTROL WIRES, AND LATERAL PIPE SHALL ASABE/ICC 802-2014 BE INSTALLED IN SEPARATE SLEEVES. 2. POP-UPS IN TURF AREAS HAVE A MINIMUM HEIGHT OF 6". 03/1/2019 NAME DATE EDWARD W PRICE ID#: 50322 Sheet Tide: IRRIGATION LEGEND&NOTES Sheet Number: IR 1 .0 :(ECEIVED 03/15/2019 ASPEN BUILDING DEPARTMENT HINES INC SITE WATER MANAGEMENT SERVICES 323 W.DRAKE RD,SUITE 204 FORT COLLINS,COLORADO 80526 Telephone:970.282.1800 Web:www.hinesinc.corn WATER EFFICIENT LANDSCAPING STANDARDS AND ORDINANCE WATER EFFICIENT LANDSCAPING STANDARDS AND ORDINANCE a I WATER EFFICIENT LANDSCAPE WORKSHEET--WATER BUDGET ANALYSIS--743 CEMETERY LANE WATER EFFICIENT LANDSCAPE WORKSHEET--WATER BUDGET ANALYSIS--745 CEMETERY LANE Note: Project Applicant must complete this worksheet as it is a required element of the Landscape&Irrigation Documentation Package. Note: Project Applicant must complete this worksheet as it is a required element of the Landscape&Irrigation Documentation Package. SECTION A.GALLONS OF WATER NEEDED BY PLANT CATEGORY AND IRRIGATION TYPE: SECTION A.GALLONS OF WATER NEEDED BY PLANT CATEGORY AND IRRIGATION TYPE: The specific irrigation water needs of each hydrozone in the design should be determined using the following formula and factors: The specific irrigation water needs of each hydrozone in the design should be determined using the following formula and factors: Irrigation Water Budget=[(ETo x Plant Factor)-Re]x Irrigated Area+Irrigation Efficiency x 0.623 Irrigation Water Budget=[(ETo x Plant Factor)-Re]x Irrigated Area+Irrigation Efficiency x 0.623 LLI CC Where: Where: ETo=Reference Evapotranspiration=27.4 inches/season(May through September) ETo=Reference Evapotranspiration=27.4 inches/season(May through September) H Re=Effective Precipitation=6.8 inches/season(May through September) Re=Effective Precipitation=6.8 inches/season(May through September) U Irrigated Area=Hydrozone Area in Square Feet Irrigated Area=Hydrozone Area in Square Feet LLI F- Water Use Category Plant Factor Irrigation Method Default Efficiency Water Use Category Plant Factor Irrigation Method Default Efficiency 2 0 0 0 0 Very High 0.90 Overhead 75% Very High 0.90 Overhead 75% U High 0.80 Drip 90% High 0.80 Drip 90% CC Medium 0.65 Medium 0.65 Low 0.40 Low 0.40 Very Low 0.25 Very Low 0.25 LLI LLI z a SECTION B.HYDROZONE INFORMATION TABLE AND WATER BUDGET CALCULATION: SECTION B.HYDROZONE INFORMATION TABLE AND WATER BUDGET CALCULATION: Q Q Complete the hydrozone table for each hydrozone. Use as many rows as necessary to provide the square footage of landscape area per hydrozone. Complete the hydrozone table for each hydrozone. Use as many rows as necessary to provide the square footage of landscape area per hydrozone. U Cn Reference ET Reference ET > ❑ 27,4 111.11 inches/year inches/year E z 17.1 gallons/square foot 17.1 gallons/square foot LLI Effective Precipitation Effective Precipitation H f inches/year Elffliinches/year LLI 4.2 gallons/square foot 4.2 gallons/square foot Hydrozone Hydrozone LLI Plant Water Need Plant Water Need Hydrozone Plant Water Use Type(s) Plant Factor Irrigation Method Irrigation Efficiency Area Hydrozone Plant Water Use Type(s) Plant Factor Irrigation Method Irrigation Efficiency Area0 CO (Sq.Ft.) (gal/season) (Sq.Ft.) (gal/season) Q ClJ Example = L T 0.40 Drip 710.90 2000 5759 Example V L 0.40 Drip = 0.90 2000 5759 U CO Zone 1-A2 Medium 0.65 Drip 90% 270 2,058 Zone 1-81 Medium 0.65 Drip 90% 335 2,553icr (b Zone 2-A5 Very High 0.90 Overhead 75% 300 4,451 Zone 2-85 Very High 0.90 Overhead 75% 275 4,080 ❑CC o Zone 3-A1/A4 Medium 0.65 Drip 90% 793 6,044 Zone 3-B2/B4 Medium 0.65 Drip 90% 493 3,757 CD ill Zone 4-A3 Medium 0.65 Drip 90% 794 6,051 Zone 4-B3 Medium 0.65 Drip 90% 1937 14,763 Zone 5-SPA High 0.80 Drip 90% 63 659 Zone 5-SPA High 0.80 Drip 90% 63 659 CO \ 0 Qin Q Zone 6-A6 Low 0.40 Overhead 75% 750 2,592 Zone 6-B6 Low 0.40 Overhead 75% 900 3,110 CIO U = O) z Zone 7 - 1.00 - 100% 0 - Zone 7 - 1.00 - 100% 0 - `'J Z r , ,X 0 Zone 8 - 1.00 - 100% 0 - Zone 8 - 1.00 - 100% 0 - �} LL V _g m m V .od - a m Zone 9 - 1.00 - 100% 0 - Zone 9 - 1.00 - 100% 0 a A 8 co Q U AR 0 Zone 10 - 1.00 - 100% 0 - Zone 10 - 1.00 - 100% 0 - I \ Zone 11 - 1.00 - 100% 0 - Zone 11 - 1.00 - 100% 0 - Designed JB Zone 12 - 1.00 - 100% 0 - Zone 12 - 1.00 - 100% 0 - Dratted: MR,JB Reviewed: MR Zone 13 - 1.00 - 100% 0 - Zone 13 - 1.00 - 100% 0 - Date Issued: Zone 14 - 1.00 - 100% 0 - Zone 14 - 1.00 - 100% 0 - 003.01.2019 TOTAL 2970 21,855 TOTAL 4003 28,922 Revision Title Date AVERAGE IRRIGATION WATER NEED-ALL ZONES*-In gallons/sq.ft./season 7.4 AVERAGE IRRIGATION WATER NEED-ALL ZONES*-In gallons/sq.ft./season 7.2 1 Revision 1 03.01.2019 *The average must be less than the Maximum Applied Water Budget of 7.5 gallons/sq.ft./season. *The average must be less than the Maximum Applied Water Budget of 7.5 gallons/sq.ft./season. 2 a Total area of irrigated Total area of irrigated 4 public right-of-way: 0 Sq.Ft. public right-of-way: 0 Sq.Ft. s Total area of Total area of a non-irrigated landscape: 0 Sq.Ft. non-irrigated landscape: 0 Sq.Ft. 7 Reviewed and Approved for IRRIGATIONHYDROZONES Sheet Tide: Water Efficient Landscaping Sheet Number Standards rickma 04/02/2019 IR 1 . 1 RECEIVED 03/15/2019 ASPEN BUILDING DEPARTMENT HINES INC 4. SITE WATER MANAGEMENT SERVICES 323 W.DRAKE RD,SUITE 204 FORT COLLINS,COLORADO 80526 Telephone:970.282.1800 Web:www.hinesino.corn \(.1--\ C J eSI .to.,��+,+ © B6 is 'Oillil 1CC r 30P` O �� _ — `1 ate-"�4 160 , `� •��1 30PSI ®� Transplanted R.O.W.Tree �--�-+ iiitit ...... \ az] �;' —.' b'°r�rx� �a'� ��� 9r`"' 5\ZE' 3/4"AN Co'5 p5\ /Ill 0.44 1 O • ..� f . r���y � ��1' � � pRE55UR�'GPO il 30PSI m I� �r�a --4111,0104400..:4•0. — t, r ----?1,;,---:;-#:01 LPL fret ® ° tiA v 1R°C U\RED �I�-i=T-.,Y 30PSI f__, �t'® 1 C�PG POW R REQ ,� ���-- o k„ :. M�tERY,me •11��e 1 `-1 S vv 12D ?. I�`F 1 v IavereRY ENE SHIFT 100 UNITS w LLI ��..Aii_.i 743 \\I' 'VP I I I"."..---*',\ \ 101 Ili (i.''''''."."..".'..\1--- - '''''Atir okle,?lit\ti$101‘.-IT.0,-•0. -----::''''''*?---:1 \ , i �, �A _ CC LLJ CO 1 WI 11� _ -,a,'i, ;:41- .�P \ '1:Mit ®04 f� 1 ���' I� � ® Transplanted R.O.W , 0 Iiii, m� '� 1 s tlAk 2.48 LL1 ve pp Y ENE ��� ., ,N, � �vC� 0 RO R REQU\RED A 038 LLJ745o CEN'ETE� N� ,1 � t�.e• 12DVP , _ ,+ L741 1 ,� .., && ,11 SIZESSURE W05 p5\ 1 I'"' 't /+/ __ 1 /''� CO '''''''' -.iktT•wesfr:e:-...::::::::::eo-tW' - ,1,_____, - 4010 la \--- A03 ,A6 12 GPM ��� LS J U ', '1 „lir, - ,, \ .\\ ''' \ % ,,„ ,,,ai co \, \\ r,.\ is ...,,,,,,,,,,s,_,, , ,,,_____„. .„. ....„,„....,,,„,„ .: ,____ ,_,„. ,.., cr, a �� • ' ems1_ (Y] r' oz X� ,il•••. Mork O 1,.0, p ������ / /� 30PSI ..W lJ .ci Z �r �� 1 � 57 o d a'CO CC tre wiligterdL _.,.iltill P l_ ��`�P_� _'tiarDesigned: JB Drafted: MR,JB 7.80 - / % �� Reviewed: MR ® O�\_ �� �' 44 ® Date Issued: 30PSI i M 30PSI 003.01.2019 PDa Information Revision Tide Date POC Flow Rate(GPM) 0.0 ! 1 1 Revision 1 03.01.2019 Tap Size .75-inch Reviewed and Approved for 2 Available Discharge(GPM) I 10 a Tap Pressure Available(Psi) 105 Water Efficient Landscaping 4 Pressure Losses 5 Sprinkler 30.0 Standards rickma 04/02/2019 6 Lateral pipe from RCV to sprinkler 3.0 Remote Control Valve 2.0 Mainline pipe from back1ow to RCV 10.5 ■--.. Master valve 2.0 Backfiow prevention device 12.0 10' 15' I1 O' I20' Water meter 3.0 SCALE:1"=10' N O R T H Service line length 100 14.4 (feet in left column,psi in right column) IRRIGATION PLAN Sheet Title: Elevation change to most remote zone 0.0 (feet in left column,psi in right column) Miscellaneous losses 0.0 Sheet Number: I Total Losses(psi): 76.9 Remaining Pressure(Peg*: 28.1 R RECEIVED 03/15/2019 ASPEN BUILDING DEPARTMENT VALVE BOX WITH LOCKING COVER: SECURE CHRISTY ID TAG WITH NYLON TYPE K HARD COPPER FROM POTABLE CARSON 1419-48. ZIP TIE. LABEL WITH CONTROLLER AND WATER SERVICE PROVIDED BY OTHERS. BRAND LID WITH "MV" FINISH GRADE STATION NUMBER. 4. N BRASS UNION (TYP.) FINISH GRADE/TOP OF MULCH I HIKS INC SECURE CHRISTY ID TAG WITH NYLONVALVE BOX WITH LOCKING COVER: VALVE BOX WITH COVER: 3/4-INCH FEBCO 825Y REDUCED ,AjiZIP TIE. LABEL WITH CONTROLLER AND CARSON 1419-4B. BRAND "FM" ON 2-INCH MIN CARSON 910-4. PRESSURE ASSEMBLY WITH SHUT-OFFSTATION NUMBER. LID W/ 3-INCH HIGH LTRS. BRAND LID WITH VALVE "IGV" VALVESSITE WATER MANAGEMENTSERVICES 323 W.DRAKE RD,SUITE 204 FORT EXTERIOR BUILDING WALL 30-INCH LINEAR LENGTH OF COLLINS,COLORADO 80526 �] (SHOWN DIAGRAMATIC) GRADE/TOP OF MULCH (LENGTH AS REQUIRED) web:COILED WIRE \� FINISH 4-INCH PVC CL PIPE ielephorre:s7oines2inca2.com1&00 www.h I WATER PROOF CONNECTION (1 OF 2) 00 TWO (2) CONDUCTOR TWISTED PAIR oo• OF,.. .,A ]C 3-INCH MINIMUM DEPTH OF MASTER VALVE, SIZE TO MATCH POC SHIELDED DIRECT BURIAL CABLE FOR o 00 { 1-INCH MALE ADAPTER W/PVC CAP �I�� CONNECTION TO TRANSMITTER o I 3/4-INCH WASHED GRAVEL � o A MODEL PER LEGEND L �� - N� 1 WATER PROOF CONNECTION (1 OF 2) BRICK (1 OF c - 3M SERIES 7000 EPDXY KIT ► 2) 1 r 1 3-INCH MINIMUM DEPTH OF I �,�_ 3/4-INCH WASHED GRAVEL _ ' c '_ ,, , _ .Pt� FLOW SENSOR PER LEGEND ,■ GATE VALVE WITH CROSS HANDLE, PIPE SUPPORT, 1 OF 2 �1111 �0 PVC MAINLINE TO SYSTEM V "' SIZED TO MATCH MAINLINE. MODEL ` PER LEGEND MECHANICAL ROOM FINISH FLOORS o'. •'• o`b MIN.10 PIPE DIA. f MIN.5 PI' DIA. _ O ° O'f,rC.0 e'Og gamFIR STRAIGHT PIPE STRAIGHT P'E LANDSCAPE AREA °oo°°� aa,o", MIN.'12 INCH 1-INCH TYPE K HARD COPPER. BRICK (1 OF 4) SFLOW I . PVC MAINLINE I PVC MAINLINE • •' TRANSITION TO CLASS 200 PVC PVC SCH 40 MALE ADAPTER (SPEARS °'0000° O°o°o�� 'O oo i MmietSI I11s PRIOR TO MASTER VALVE. l 000lPoCT QoO000000°o 80 NON SR-2-0801)WOVEN LANDSCAPE FABRIC �`\`'o oa oo°°o o e s�o e .P' ►' BRICK (1 OF 4) SCH 40 PVC MALE ADAPTER PVC SCH. 40 MALE ADAPTER NOTES: (SPEARS 436 SERIES) CC (SPEARS 436 SERIES) 1 OF 2 1. INSTALL BACKFLOW DEVICE IN ACCORDANCE WITH ALL LOCAL AND STATE CODE NOTES: REQUIREMENTS. 3-INCH MINIMUM DEPTH OF 1. NOMINAL SIZE OF GATE VALVE TO MATCH NOMINAL MAINLINE SIZE. 2. PROVIDE SHOP DRAWING OF BACKFLOW ASSEMBLY AND PIPE ROUTING WITHIN 3/4-INCH WASHED GRAVEL MECHANICAL ROOM FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. NON-WOVEN LANDSCAPE FABRIC BACKFLOW PREVENTION UNIT O ASSEMBLY IN MECHANICAL ROOM MASTER VALVE FLOW SENSOR ISOLATION GATE U ©ASSEMBLY ©ASSEMBLY 4 VALVE ASSEMBLY I- SECURE CHRISTY ID TAG WITH NYLON CHRISTY ID TAG 1 ZIP TIE. LABEL WITH CONTROLLER AND VALVE BOX WITH COVER: STATION NUMBER. FINISHED GRADE CARSON 910-4. 30-INCH LINEAR LENGTH OF WIRE, VALVE BOX WITH COVER: CARSON - 3" MIN BRAND LID WITH VALVE "QC" COILED 1419-4. IRRIGATION CONTROL WIRES SECURED 3-INCH MAX BRAND LID WITH VALVE NUMBER TO BOX WITH NYLON ZIP TIE. CC WATER PROOF CONNECTION (1 OF 2) IRRIGATION VALVE SENSOR ASSEMBLY ' FINISH GRADE FINISH GRADE/TOP OF MULCH VALVE/SENSOR ' II ,- - --, (ABOVE GRAVEL) j/j I '\f QUICK COUPLING VALVE PER LEGEND VALVE BOX WITH COVER: CARSONd v WATER PROOF CONNECTION (1 OF 2) / 1t1 ° 3.0-INCH MINIMUM DEPTH OF %i L . STAINLESS STEEL HOSE CLAMP 1419-4. BRAND LID WITH VALVE NUMBER 42014 30-INCH LINEAR LENGTH OF WIRE, oo �oo� 3/4-INCH WASHED GRAVEL LLJ (1 OF 2) REMOTE CONTROL VALVE, SIZED AS V 3 M/ COILED ood�' LLI t I .1 00 ;0=.... go°,too mo o� BRICK (1 OF 4) SHOWN ON DRAWINGS I��I - I REMOTE CONTROL VALVE, SIZED AS 36-INCH No. 6 EPDXY COATED REBAR i ', �? I SHOWN ON DRAWINGS APPROVED GEOTECH FILTER FABRIC ■_ I k _--la FINISH GRADE/TOP OF MULCH , �� ::.` ( ) Q `` �r ■ �I� EXTEND 10" UP BOX WALL •1- 3-INCH DEPTH OF 3/4-INCH WASHED _ ■ r SPEARS PVC TRUE UNION BALL VALVE / SECURE CHRISTY ID TAG WITH NYLON ICI-r ■ �_ 1 GRAVEL 1f �=\ 3"MIN. _ _11 J■0� ' I[ STANDARD QUICK U ZIP TIE. LABEL WITH CONTROLLER AND 1 APPROVED GEOTECH FILTER FABRIC '08 00 o'-12SggP 1. -BRICK 801 PVCF NIPPLE, TOE \ �•.� I �� go o o;o o'�.oo oo f 11. (EXTEND 10" UP BOX WALL) o i o c COUPLER VERBO ISOLATION Cr)I�, iSTATION NUMBER. I loo oo oo,° o�l` uJ (LENGTH VARIES) - �� SPEARS PVC TRUE UNION BALL VALVE �� °"'� �� PVC SCH 80 PIPE (LENGTH AS /-� c '���'." PVC SCH 40 EL REQUIRED) PRE-FABRICATED SWING JOINT: '.�"��I` L PVC MAINLINE V ` 4., SPEARS 5815 010 10 / I BRICK (1 OF 4) '' '`'' Iuuuui *, BRICK (1 OF 4) MIN 12" ► _ RSTANDARD CARBON 1419 CC LLI(� �, °0 es�o v0' PVC SCH 80 PIPE PVC SCH 40 TEE OR EL MIN 12 BOX OTE CONTROL VALVE PVC MAINLINE PIPE o / (LENGTH AS REQUIRED) LOOP 1' OF 2 SPARE WIRES MIN�12" y.TURF OR PLANTING BED LLI _I SCH 40 PVC TEE OR EL WITH FPT • N •PVC MAINLINE COMBINED PRESSURE REGULATOR 40 T AND Y-STRAINER OUTLET PVC • SCH TEE OR EL 3.0-INCH MINIMUM DEPTH OF R�, "' AAVEMENT OR EDGING RESTRAINT 3/4-INCH WASHED GRAVEL NOTES: NOTE: 1. INSTALL ONLY ONE RCV TO VALVE BOX. LOCATE AT LEAST 12-INCHES FROM LLI - PVC SCH 40 MALE ADAPTER AND ALIGN WITH NEARBY WALLS OR EDGES OF PAVED AREAS. GROUP RCV 1. USE BARBED INSERT FITTINGS ON DRIP LATERAL PIPE WITH STAINLESS STEEL HOSE (SPEARS SR-2-0801) CLAMPS. PLACE CLAMPS ON DRIP TUBING DIRECTLY OVER BARBED AREA OF FITTING. ASSEMBLIES TOGETHER WHERE PRACTICAL. U CO-3.0-INCH MINIMUM DEPTH OF PINCH CLAMPS ARE NOT ACCEPTABLE. 4. GROUP RCV ASSEMBLIES TOGETHER WHERE PRACTICAL, BUT AVOID GROUPING CU 3/4-INCH WASHED GRAVEL MORE THAN THREE (3) STANDARD VALVE BOXES TOGETHER IN A SERIES. U CO5. ARRANGE GROUPED VALVE BOXES IN RECTANGULAR PATTERNS. In O QUICK COUPLING 6 REMOTE CONTROL TURF ØREMOTECONTROLDRIP 8 TYPICAL VALVE BOX 0 o VALVE ASSEMBLY VALVE ASSEMBLY VALVE ASSEMBLY INSTALLATION coCC U Lii '.---TYPICAL RAIN/FREEZE/WIND SENSOR; o Q I, - PROPERLY MOUNTED ON POST OR PROFILE VIEW PLAN VIEW 0 Q Ln IRRIGATION CONTROLLER. U IIGUTTER TO RECEIVE FULL SUN, OPEN MAINLINE, LATERAL, PIPE AND WIRE ��-yy-'�� TO RAINFALL AND OUT OF SPRINKLER #6AWG SOLID BARE COPPER WIRE #6AWG SOLID BARE COPPER WIRE & 24-V WIRE LATERAL PIPE SLEEVING CO z �� O COVERAGE. 4" X 96" X n6" IIWALL MOUNTED CONTROLLER COPPER GROUNDING PLATE 12" MIN j\ FINISH GRADE CONCRETE SLAB .`g O _. - am oc (REFER TO LEGEND FOR MODEL) eY)'r>a"G�1>,oIYYIMIG(�lYYtL v1YYlM$�)ti'lUi((lYY`��lA ol>a `G! A{�14 {�1 {��pLyy'k( �p '(4{,,T{ �(,�(� CC �O Q COMMUNICATION WIRE INSTALLED IN GROUNDING CLAMP 3LAl* aE Q c3 5a U • CONDUIT; MAX WIRE DISTANCE: 200'. rCONNECT10N L /�i 34V WALL (WIRELESS OPTIONAL; REFER TO LEGEND) 30" MIN 1 i / / jDegned: JB 120 VOLT POWER SUPPLY WIRES INW 18" 1 Drafted: MR.JB METAL CONDUIT -Y - �� � 24" Reviewed MR �� L MINIMUM 10 FT. PVC CONDUIT FOR CONTROL WIRES L L / o i ,\ 4" 4 24„ Date Issued: i 0003.01.2019 TO LANDSCAPED AREA F► 3L ►iPVC SWEEP ELL 6 BARE COPPER GROUNDING WIRE IN 4" X\ 6" X Ys"! # y ss 4., Revision Tide DaruIII i PiI, METAL CONDUIT I I I [ / i� C OPPER,GROUf�e PLATE 1 5' SIZE ■ 2L I / / \ 4" /� 1 Revision 1 03.01.2019 PAVEMENT y�0 gad:' ® � FINISH GRADE \ \ -./ / I / / / \ \ \II�IIIk711III -_ \ \ / / I \1- - 11-111 .I-111- l PVC SWEEP ELL \ �� /�/ / I i 1 EXCAVATED MATERIAL l` \ / 1 I �//, 4 1� '4; DIRECT BURIAL CONTROL WIRES TO #6AWG SOLID COPPER BARE WIRE \---' //6AWG STOLID BARE COPPER WIRE I I i i PIPE WIRING s CONTROL VALVES 0. BEDDING&COVER MATERIAL SLEEVE SLEEVE 6 ' �� �� 5/8"X10' GROUNDING ROD. I \ \ \ / I I COPPER GROUNDING WIRE J---------.-------. �1 ELECTRODE SPHERE OF INFLUENCE TO BRONZE CLAMP. = =/ \` - �/ \ \ \ // // I �' WARNING TAPE v COPPER CLAD GROUND ROD \ \ L - / / NOTES: (5/8" X 8') PAIGE ELECTRIC \� ✓ 7/ // 1. SLEEVE ALL PIPE AND WIRE SEPARATELY. NOTES: PART NUMBER 182007. ___ / 2. ALL PIPE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS."SNAKE" UNSLEEVED N N INSTALL ALL WIRING PER LOCAL ELECTRICAL CODES. NOTES: \ �/ PLASTIC PIPE IN TRENCH. PROVIDE A MINIMUM OF 2" CLEARANCE TO SIDE OF TRENCH 1. INSTALL GROUNDING ROD OR PLATE BASED ON SITE CONDITIONS, DO NOT INSTALL BOTH. 2. INSTALL GROUND ROD WITHIN IRRIGATED TURF AREA. IF IRRIGATED TURF AREA IS NOT IN 2. DO NOT INSTALL ANY OTHER WIRE OR CABLES INSIDE THE SPHERE OF INFLUENCE. AND BETWEEN PIPES. CLOSE PROXIMITY TO CONTROLLER, INSTALL ONE (1) DRIP EMITTER FROM NEAREST DRIP 3. INSTALL GROUNDING PLATE AT A MINIMUM OF 30-INCHES BELOW GRADE OR BELOW FROS 3. ALL 120-V WIRING SHALL BE INSTALLED IN ACCORDANCE WITH LOCAL CODE VALVE IN VALVE BOX HOUSING GROUNDING ROD. 4. TYPICAL INSTALLATION SHOWN FOR AN IRRIGATION CONTROLLER CAPACITY OF 64 STATIONS Reviewed and Approved for IONS. REQUIREMENTS. TAPE AND BUNDLE 24-V WIRE EVERY 10' AND PROVIDE LOOSE 20" LOOP Sheet Tide: AT ALL CHANGES OF DIRECTION OVER 30 DEGREES. IRRIGATION DETAILS Water Efficient Landscaping WALL MOUNT TYPICAL IRRIGATION CONTROLLER GROUNDING TYPICAL TRENCHING Sheet Number: 9 CONTROLLER ASSEMBLY 1 O ROD OR PLATE INSTALLATION Standards rickma 04/02/20194111 DETAIL IR 3.0 RECEIVED 03/15/2019 ASPEN BUILDING DEPARTMENT PAVED SURFACE LANDSCAPE DRIPLINE TUBING: CURB AND GUTTER IF APPLICABLE MODEL PER LEGEND TIE DOWN STAKE SPRAY NOZZLE, PER PLAN: i� RAIN BIRD TDS-050 W/BEND / HINES INC SEE LEGEND FOR MODEL (QTY. AS REQUIRED) DIFFUSER BUG CAP: 36" A' I / \ RAIN BIRD MODEL DBC-025 12" MIN ���i��'�I)�)1`��11��(fj� ��)i��l�����1����i�i��i;�,�����1� FINISH GRADE/TOP OF MULCH 1/4-INCH TUBING STAKE: \�I�I�� �� • \ RAIN BIRD #TS-025 SITE WATER MANAGEMENT SERVICES 7W. SUITE FORT -III_ ROUGH GRADE -III— —Ili ./-- \ \ TREE TRUNK 1/4-INCH DISTRIBUTION TUBING COLLI323NS,DRAKELRD,COLORAD080526204 / Telephone:970.282.1800 I I I �2"PVC PIPE SLEEVE MARKER: INSTALL AT -III — POP-UP SPRAY BODY: / `\ TREE ROOTBALL Web:www.hinesinc.com IIIIIIIII- -III- BOTH ENDS OF EACH SLEEVE LOCATION AND — WITH CHECK VALVE AND PRESSURE MULCH BED ���������� IIIEIII III �� EXTEND AT LEAST 3'ABOVE GRADE. SPRAY REGULATING VALVE FEATURES VVV —�—� —1 EXPOSED PORTION OF MARKER WITH GREEN SEE LEGEND FOR MODEL I (10 III—III— -III- FLUORESCENT PAINT. I ` . l/ / DRIP EMITTER 24-INCH MIN // (REFER TO SPECIFICATIONS) 1/2-INCH MALE NPT x .490 INCH \ / � / \�����/j j /j� /� j/ i 4"-6" MIN. / .// / /f ^ / BARB ELBOW: RAIN BIRD MODEL ` �-- / �� (��� // a� I O' OII \BE SBE-050 ` //�. \. ��/ /- 4 4 LJ b `-� SCH 40 TEE SxSXFIPT /1�j// ��9 // 4" K"MIN. ' \ \\'\\\\ \\\\\\\\\\\\�\� FINSH GRADE _ ' PVC LATERAL PIPE • =;wa a 3/4-INCH POLY \\�\Y`�\\�\< \�\�\\�\\�\\�\\�\\�\\SEAL ENDS OF SLEEVES WITH CLOTH DUCT TAPE (TYPICAL) PVC SLEEVING (TYPICAL) SCH 80 ELBOW DRIP LATERAL PIPE w PVC SCH. 40 TEE OR EL NOTE: SWING PIPE, 12-INCH LENGTH: NOTE: PLANT ROOT BALLCC 1) ALL SLEEVING TO BE CLASS 200 BE PVC, SIZED AS NOTED. RAIN BIRD SPS-FLEX100 1. CONTRACTOR SHALL INSTALL ALL DRIP TUBING IN TURF AND NATIVE AREAS 2-3" 2) INSTALL SLEEVES IN SIDE-BY-SIDE CONFIGURATION WHERE MULTIPLE SLEEVES BELOW GRADE. D ARE TO BE INSTALLED. SPACE SLEEVES 4" TO 6" APART. DO NOT STACK SLEEVES 2. UTILIZE 25-FEET OF LANDSCAPE DRIP ON ALL TREES, CONCENTRIC RING DIAMETER VERTICALLY. DEPENDANT ON LANDSCAPE AREA AVAILABLE. TYPICAL SLEEVING 6-INCH POP UP SPRAY INLINE DRIP RING SPIRAL SINGLE OUTLET DRIP LLI e DETAIL (1) SPRINKLERASSEMBLY 14 ASSEMBLY FOR TREES IN NATIVE ® EMITTER ASSEMBLY I— I— I 2-4" ® U RAIN BIRD MODEL # DBC-025 T.,..i__Fn DRIP LINE TUBING LATERAL: 1/2" DIFFUSER BUG CAP NETAFIM TECHLINE WITH 0.26 GPH CC • VALVE BOX WITH COVER: CARSON 708-4. FINISH GRADE EMITTERS 12" O.C. (TYP) MODEL MULCH BRAND LID WITH "FC" TECHLINE TEE • 6" • . • t 12" TLCV26-12 FINISH GRADE • 16" REMOTE CONTROL VALVE REFER •i� i i i i �I �y�� FINISH GRADE/TOP OF MULCH TECHLINE TUBING TO DETAIL #X LLI LLI i ���� '-_�/ I • PVC SUPPLY HEADER Z 1� RAIN BIRD MODEL #TS-025 FLUSH CAP: 3/4-INCH BARB X �� 1/4" TUBING STAKE(TYPICAL) 3/4-INCH M NPT ADAPTER AND THREADED CAP • J U BLANK TECHLINE • 3 4-INCH DRIP LATERAL PIPE MINTUBING `1 4-INCH DISTRIBUTION TUBING / ( TECHLINE START CONNECTION /y/ 12-INCHES LOOPED) • (PVC TO ELL): REFER TO ❑ RAIN BIRD MODEL # XB-10-6 3-INCH DEPTH OF 3/4-INCH TECHLINE 3 4" DETAIL #XMULTI-OUTLET XERI-BUG EMITTER�� ' WASHED GRAVEL MALE ADAPER AREA PERIMETER3/4-INCH MALE BARBED ELBOWL� PVC TEE (SxSxT)_DRIP LATERAL TUBING oo BRICK OF 2 PVC EXHAUST HEADER I 1 1° ooB • (1 ) PVC PIPING LU DRIP EMITTER BOX �• FLUSH CAP ASSEMBLY PLUMBED TO �!!!!!! 3/4-INCH DRIP LATERAL PIPE PVC (TYP) 3/4" CRUSHED STONE • C C� CURB OR PLANTING BED EDGE • C, NOTES: LLI 2 1. INSTALL SYSTEM PER MANUFACTURER'S INSTRUCTIONS AND RECOMMENDATIONS NOTE: ' . FOR EQUIPMENT APPLICATION AND INSTALLATION. Ci CID 1. LOOP IRRIGATION DRIP TUBING INSIDE VALVE BOX FOR EXTENSION OUTSIDE OF 2. MAXIMUM FLOW FOR 1-INCH REMOTE CONTROL VALVE ASSEMBLY IS 10 GPM. Q Cl.l BOX DURING BLOWOUT. 3- INSTALL AT A DEPTH OF 4"-6" IN UNIFORM SOIL. U In CO 1 r MULTI-OUTLET DRIP EMITTER . DRIP FLUSH CAP 1 8 PVC TECHLINE 1 9 SUBSURFACE DRIP icr — 00 V ASSEMBLY FOR TREES IN BEDS ASSEMBLY CONNECTION ASSEMBLY IN SHRUB BEDS c CC o LL.f m _1a 2 4 O \ O CD CI --m.- F t=,i��=� IN-LINE DRIP TUBING FROM SHRUB BED m z DRIP LINE TUBING LATERAL: 1/2" ` J z igX Q NETAFIM TECHLINE WITH 0.26 GPH LLI U a`m m EMITTERS 18" O.C. (TYP) MODEL a G m 12" TLCV26-18 a A J U Ua m REMOTE CONTROL VALVE REFER 77rC-2) Q TEE FITTING I \ / TO DETAIL #7 /. Designed: JB PVC SUPPLY HEADER Drafted: MR,JB Reviewed: MR \ IN-LINE DRIP TUBING: Date Issued: REFER TO LEGEND 003.01.2019 \\/\ / \ FOR MODEL Revision Tide Date TECHLINE START CONNECTION I 1 Revision 1 03.01.2019 (PVC TO ELL): REFER TO#18 �� TREE ROOTBALL z l DETAIL Reviewed and Approved for 3 AREA PERIMETER �i Water Efficient Landscaping 4 ESTIMATED DRIPLINE 5 \ / OF MATURE TREE Standards rickma 04/02/2019 PVC EXHAUST HEADER 6 LINE FLUSHING VALVE FLUSH CAP ASSEMBLY PLUMBED TO REFER TO DETAIL #X PVC (TYP) \ LF CURB OR TURF BED EDGE \ NOTES: 1. INSTALL SYSTEM PER MANUFACTURER'S INSTRUCTIONS AND RECOMMENDATIONS FOR EQUIPMENT APPLICATION AND INSTALLATION. TECHLINE TEE 2. MAXIMUM FLOW FOR 1-INCH REMOTE CONTROL VALVE ASSEMBLY IS 10 GPM. 3. INSTALL AT A DEPTH OF 4"-6" IN UNIFORM SOIL. Sheet Title: IRRIGATION DETAILS 20 SUBSURFACE DRIP INLINE DRIP TREE RING Sheet Number: ASSEMBLY IN TURF AREAS 4111 FOR TREES IN SHRUB BED R 3. 1 RECEIVED 03/15/2019 ASPEN BUILDING DEPARTMENT