HomeMy WebLinkAboutFile Documents.34 Westview Dr.0056.2018 (5).ARBK 0056-2018-ARBK_BuildingComments_1
Architecturals +Zsheets.pdf(9)
Page:A-2.1 FLOOR PLAN
File Name: Architecturals+Zsheets.pdf Smo nd CO detectors are
Subject: PlanCheck sh n correctly on the RCPs but
Author: nickt ' correctly on the floor plans.
Color: • Please remove them from the
Essig--l_l floor plans.
r $ Imo_, m Smoke and CO detectors have been
—,l..- - removed from floor plans.
r
RE: A2.1
Page:A-2.2 PLAN
File Name: Architecturals+Zsheets.pdf Smoke an detectors are
Subject: PlanCheck show rectly on the RCPs but
Author: nickt ' orrectly on the floor plans.
- Color: • Please remove them from the
M floor plans.
fril7s_r - Ilei ;' Smoke and CO detecto ve been
..— ®mil removed from floor plans.
RE: A2.2
Page:A-2.2 PLAN You show 1'-4"from cente ' - of
File Name: Architecturals+Zsheets.pdf watercloset to edge • d.
Subject: PlanCheck
Author: nickt Depending on fi•' es,this gets
Q° — Color: ■ very close t• e minimum
I - :� ` require , t of 1'-3". Consider
.°._� l i Revised to 1 -6 from CL pr. •.ing more room. (2015 IPC
~ , C. RE: A2.2, Revised Layout
.5.3.1)
,._. Page:A-3.1 ELEVATIONS Window M is ress window;
NE
" File Name: Architecturals+Zsheets.pdf fall protectio opening control
fli Subject: PlanCheck
,�-- �' device m be listed to ASTM
{_ = ,, �-° o Author: nickt
.►��-,/.- Y F 2090 2015 IRC R312.2)
e Color: •
-,_. ---
AO
-�f Note added to elevation &
..E..;M Window ScheduleRE: A3.1
A-3.1 & A7.0
Page:A-3.1 ELEVATIONS
File Name:Architecturals+Zsheets.pdf Overcurrent devic ctric
Subject: PlanCheck service d' ect)may not be
'171 I over a slope. Provide a
Author: nickt
I evel working space. (2017 NEC
4 _ Color: • 240.24 (F))
III E Edge of gas meter must be at
rI
Y , . o Notes added to elevation least 12"from service per utility
2 11 - _ff , I 1 requirements.
-- ram, RE: A31.
RECEIVED
08/22/2018
ASPEN
BUILDING DEPARTMENT
III Page:A5.1 WALL SECTIONS Your .- ''cce-not come,tly
File Name:Architecturals+Zsheets.pdf
Subject: Group • -• edge insu a,-
• -. - • RESchec
Author: nickt
Color: • S .b-on-grade floor - •or
su 'ace less than 12"below
m L m A51 gra.- must have insulation
exten. • downward from e
Insulation updated to top of the s-_ •n the • side or
p inside of the foun•a on wall.The
Comply with REScheck RE: insulation must be extended for
A5 series by any combination of vertical
insulation, insulation extending
under the slab or insulation
extending out from the building.
See the details below for
examples.Your REScheck calls
for 6'of R-15 insulation. Revise
details or REScheck as
necessary.(2015 IECC 402.2.10)
Page:A5.2 WALL SECTIONS
Your details do not correctly
File Name:Architecturals+Zsheets.pdf
Subject: Group show the slab edge insulation
Author: nickt called for in your R c
Color: • Slab-on-gr.oe floors wi - 'or
surface I:.-s than 12"below
hh} �
grade m st have insulation
extendi g downward from the
top oft e slab on the outside c r
Insulation updated to inside 6, the foundation wall. ' e
insulatio .e extend-• 'or
Comply with REScheck RE: by any combination of vertical
A5 series insulation, insulation extending
under the slab or insulation
extending out from the building.
See the details below for
examples.Your REScheck calls
for 6'of R-15 insulation. Revise
details or REScheck as
necessary.(2015 IECC 402.2.10)
p j 1 __I_ Page:A6.2 DETAILS
- File Name: Architecturals+Zsheets.pdf Glass guards must c• ply with
n Subject: Glass guards one of the followin. ave a top
VPig ""°" i�,, Author: nickt cap supported b at least 3
•••••_• panes of glas ave a top cap
.... -, Color: •
___z' supported i .ependent of the
("Tr glass; or i' the case of no top
cap, b- :t least two plies of
Detail revisedRE: A6.2 eq hickness glass laminated
:.ether. Provide details
demonstrating compliance with
one of the above as well as
method of attachment and
support. Must support a point
load of 2001bs. Please note that
many glass support
manufacturers require a top cap;
if you exceed their design you
will need a stamped engineered
design. (Ordinance 40, 2016)
RECEIVED
08/22/2018
ASPEN
BUILDING DEPARTMENT
v s��k Page:AB-1.0 EXISTING SITE PLAN
File Name:Architecturals+Zsheets.pdf Prov' e an approved Demolition
fi IP _ Subject: State Demo License A royal Notice or a Demolition
Author: nickt otification Application Form
/ Color: ■ stamped approved by the
f a==-=-Ru Abatement is needed and CDPHE.
'7y' / will be complete by permit
__-. pick-up
Energy Calc Documents.34westview.2018.0315.pdf(1)
Page: 2 The portion of the pe ' eter of
File Name: Energy Calc the lower level sla ess than 12"
Documents.34westview.2018.0315.pdf
Subject: PlanCheck below grade is ch less than
Author: nickt Abatement is needed and 198'; close 0'. Revise
Color: ■ will be complete bypermit RE . (2015 IECC
Y = 2.2.10)
pick-up
Landscapes.pdf(2)
Page: LS3.1 LANDSCAPE LIGHTING LAYOUT
1 �� �;�! � Architetcurals show the fire table
� �;�`,i � File Name: Landscapes.pdf
Subject: PlanCheck between the chairs on the deck.
1 ■ f L pes s ' n the lower
Author: nickt
F"'"'"'amE - atio. Coordinate a d
�� EM7 Color: ■
^�" On the Arch drawings we are showing the m n demonstrate complian ith
level deck fire table. See attached s ec kit fo manufacturer's required
Z ;t; p arance to combustible
use on combustible decks. Also noted on A2.2
The Landscape fire feature was on the lower
level back patio, but has since been eliminated
Page: LS3.2 LANDSCAPE LIGHTING SPECS
File Name: Landscapes.pdf Provide a manufacturer's
Subject: PlanCheck install ion instructions for the
Author: nickt fire t le showing required
Color: • cle ances to combustibles.
®�_ R ise floor plans to show
stance from fire table to
The landscape fire feature on the lower level combustibles.
back patio has been removed from the plan.
REMP Calcuations.34westview.2018.315.pdf(3)
Page: 1 Fill out th ottom of the REMP
_ File Name: REMP Calcuations.34westview.2018.315.pdf
worksh t and sign.
Subject: PlanCheck
_ Author: nickt
__ Color: •
Find enclosed REMP worksheet / signed
RECEIVED
08/22/2018
ASPEN
BUILDING DEPARTMENT
Page: 2 Fill out t bottom of the PV
File Name: REMP Calcuations.34westview.2018.315.pdf
Subject: PlanCheck worksh et and sign.
Author: nickt
Color: ■ Find enclosed REMP worksheet/ signed
Page: 2
File Name: REMP Calcuations.34westview.2018.315.pdf The provided cutshe sives a
Subject: PlanCheck panel (DC)capa ' • of 360W
Author: nickt and an inve - (AC)capacity of
M!LI Color: ■ 320W.Th- roof plan shows two
groups • 8 panels. This means
Find enclosed revised REMP worksheet inve• r capacity for each group
-.uld be 320x8=2.56kW. DC
side capacity should be
360x8=2.88kW. Revise REMP
PV worksheet.
SolarPVdrawings.pdf(1)
Page: RE1.0 PROPOSED SOLAR LAYOUT
File Name: SolarPVdrawings.pdf Revise PV plan to Indic
Subject: PlanCheck orientation from sou nd angle
Author: nickt from horizontal. ould match
Color: • REMP PV w sheet.
Find enclosed new PV drawings describing
size and angle in coordination with the REM
worksheet
SpeciallnspectionAgreement.34westview.2018.315.pdf(1)
Page: 3 Please have the specia
File Name: SpeciallnspectionAgreement.34westview.2018.315 inspector and fabric r sign the
.pdf
Subject: PlanCheck special inspectio greement.
Co nickt
Color:
■ Find enclosed special inspection filled out
and signed.
Structurals.pdf(1)
® Page: S-100 GENERAL NOTES
File Name: Structurals.pdf Ground snow load i Opsf per
w...A.. , Subject: PlanCheck Ordinance 40, 6.
_.= , Author: nickt
Color: •
Find enclosed revised structural note
RECEIVED
08/22/2018
ASPEN
BUILDING DEPARTMENT