HomeMy WebLinkAboutFile Documents.34 Westview Dr.0056.2018 (5).ARBK 0056-2018-ARBK_BuildingComments_1 Architecturals +Zsheets.pdf(9) Page:A-2.1 FLOOR PLAN File Name: Architecturals+Zsheets.pdf Smo nd CO detectors are Subject: PlanCheck sh n correctly on the RCPs but Author: nickt ' correctly on the floor plans. Color: • Please remove them from the Essig--l_l floor plans. r $ Imo_, m Smoke and CO detectors have been —,l..- - removed from floor plans. r RE: A2.1 Page:A-2.2 PLAN File Name: Architecturals+Zsheets.pdf Smoke an detectors are Subject: PlanCheck show rectly on the RCPs but Author: nickt ' orrectly on the floor plans. - Color: • Please remove them from the M floor plans. fril7s_r - Ilei ;' Smoke and CO detecto ve been ..— ®mil removed from floor plans. RE: A2.2 Page:A-2.2 PLAN You show 1'-4"from cente ' - of File Name: Architecturals+Zsheets.pdf watercloset to edge • d. Subject: PlanCheck Author: nickt Depending on fi•' es,this gets Q° — Color: ■ very close t• e minimum I - :� ` require , t of 1'-3". Consider .°._� l i Revised to 1 -6 from CL pr. •.ing more room. (2015 IPC ~ , C. RE: A2.2, Revised Layout .5.3.1) ,._. Page:A-3.1 ELEVATIONS Window M is ress window; NE " File Name: Architecturals+Zsheets.pdf fall protectio opening control fli Subject: PlanCheck ,�-- �' device m be listed to ASTM {_ = ,, �-° o Author: nickt .►��-,/.- Y F 2090 2015 IRC R312.2) e Color: • -,_. --- AO -�f Note added to elevation & ..E..;M Window ScheduleRE: A3.1 A-3.1 & A7.0 Page:A-3.1 ELEVATIONS File Name:Architecturals+Zsheets.pdf Overcurrent devic ctric Subject: PlanCheck service d' ect)may not be '171 I over a slope. Provide a Author: nickt I evel working space. (2017 NEC 4 _ Color: • 240.24 (F)) III E Edge of gas meter must be at rI Y , . o Notes added to elevation least 12"from service per utility 2 11 - _ff , I 1 requirements. -- ram, RE: A31. RECEIVED 08/22/2018 ASPEN BUILDING DEPARTMENT III Page:A5.1 WALL SECTIONS Your .- ''cce-not come,tly File Name:Architecturals+Zsheets.pdf Subject: Group • -• edge insu a,- • -. - • RESchec Author: nickt Color: • S .b-on-grade floor - •or su 'ace less than 12"below m L m A51 gra.- must have insulation exten. • downward from e Insulation updated to top of the s-_ •n the • side or p inside of the foun•a on wall.The Comply with REScheck RE: insulation must be extended for A5 series by any combination of vertical insulation, insulation extending under the slab or insulation extending out from the building. See the details below for examples.Your REScheck calls for 6'of R-15 insulation. Revise details or REScheck as necessary.(2015 IECC 402.2.10) Page:A5.2 WALL SECTIONS Your details do not correctly File Name:Architecturals+Zsheets.pdf Subject: Group show the slab edge insulation Author: nickt called for in your R c Color: • Slab-on-gr.oe floors wi - 'or surface I:.-s than 12"below hh} � grade m st have insulation extendi g downward from the top oft e slab on the outside c r Insulation updated to inside 6, the foundation wall. ' e insulatio .e extend-• 'or Comply with REScheck RE: by any combination of vertical A5 series insulation, insulation extending under the slab or insulation extending out from the building. See the details below for examples.Your REScheck calls for 6'of R-15 insulation. Revise details or REScheck as necessary.(2015 IECC 402.2.10) p j 1 __I_ Page:A6.2 DETAILS - File Name: Architecturals+Zsheets.pdf Glass guards must c• ply with n Subject: Glass guards one of the followin. ave a top VPig ""°" i�,, Author: nickt cap supported b at least 3 •••••_• panes of glas ave a top cap .... -, Color: • ___z' supported i .ependent of the ("Tr glass; or i' the case of no top cap, b- :t least two plies of Detail revisedRE: A6.2 eq hickness glass laminated :.ether. Provide details demonstrating compliance with one of the above as well as method of attachment and support. Must support a point load of 2001bs. Please note that many glass support manufacturers require a top cap; if you exceed their design you will need a stamped engineered design. (Ordinance 40, 2016) RECEIVED 08/22/2018 ASPEN BUILDING DEPARTMENT v s��k Page:AB-1.0 EXISTING SITE PLAN File Name:Architecturals+Zsheets.pdf Prov' e an approved Demolition fi IP _ Subject: State Demo License A royal Notice or a Demolition Author: nickt otification Application Form / Color: ■ stamped approved by the f a==-=-Ru Abatement is needed and CDPHE. '7y' / will be complete by permit __-. pick-up Energy Calc Documents.34westview.2018.0315.pdf(1) Page: 2 The portion of the pe ' eter of File Name: Energy Calc the lower level sla ess than 12" Documents.34westview.2018.0315.pdf Subject: PlanCheck below grade is ch less than Author: nickt Abatement is needed and 198'; close 0'. Revise Color: ■ will be complete bypermit RE . (2015 IECC Y = 2.2.10) pick-up Landscapes.pdf(2) Page: LS3.1 LANDSCAPE LIGHTING LAYOUT 1 �� �;�! � Architetcurals show the fire table � �;�`,i � File Name: Landscapes.pdf Subject: PlanCheck between the chairs on the deck. 1 ■ f L pes s ' n the lower Author: nickt F"'"'"'amE - atio. Coordinate a d �� EM7 Color: ■ ^�" On the Arch drawings we are showing the m n demonstrate complian ith level deck fire table. See attached s ec kit fo manufacturer's required Z ;t; p arance to combustible use on combustible decks. Also noted on A2.2 The Landscape fire feature was on the lower level back patio, but has since been eliminated Page: LS3.2 LANDSCAPE LIGHTING SPECS File Name: Landscapes.pdf Provide a manufacturer's Subject: PlanCheck install ion instructions for the Author: nickt fire t le showing required Color: • cle ances to combustibles. ®�_ R ise floor plans to show stance from fire table to The landscape fire feature on the lower level combustibles. back patio has been removed from the plan. REMP Calcuations.34westview.2018.315.pdf(3) Page: 1 Fill out th ottom of the REMP _ File Name: REMP Calcuations.34westview.2018.315.pdf worksh t and sign. Subject: PlanCheck _ Author: nickt __ Color: • Find enclosed REMP worksheet / signed RECEIVED 08/22/2018 ASPEN BUILDING DEPARTMENT Page: 2 Fill out t bottom of the PV File Name: REMP Calcuations.34westview.2018.315.pdf Subject: PlanCheck worksh et and sign. Author: nickt Color: ■ Find enclosed REMP worksheet/ signed Page: 2 File Name: REMP Calcuations.34westview.2018.315.pdf The provided cutshe sives a Subject: PlanCheck panel (DC)capa ' • of 360W Author: nickt and an inve - (AC)capacity of M!LI Color: ■ 320W.Th- roof plan shows two groups • 8 panels. This means Find enclosed revised REMP worksheet inve• r capacity for each group -.uld be 320x8=2.56kW. DC side capacity should be 360x8=2.88kW. Revise REMP PV worksheet. SolarPVdrawings.pdf(1) Page: RE1.0 PROPOSED SOLAR LAYOUT File Name: SolarPVdrawings.pdf Revise PV plan to Indic Subject: PlanCheck orientation from sou nd angle Author: nickt from horizontal. ould match Color: • REMP PV w sheet. Find enclosed new PV drawings describing size and angle in coordination with the REM worksheet SpeciallnspectionAgreement.34westview.2018.315.pdf(1) Page: 3 Please have the specia File Name: SpeciallnspectionAgreement.34westview.2018.315 inspector and fabric r sign the .pdf Subject: PlanCheck special inspectio greement. Co nickt Color: ■ Find enclosed special inspection filled out and signed. Structurals.pdf(1) ® Page: S-100 GENERAL NOTES File Name: Structurals.pdf Ground snow load i Opsf per w...A.. , Subject: PlanCheck Ordinance 40, 6. _.= , Author: nickt Color: • Find enclosed revised structural note RECEIVED 08/22/2018 ASPEN BUILDING DEPARTMENT