HomeMy WebLinkAboutFile Documents.34 Westview Dr.0056.2018 (21).ARBK REScheck Software Version 4.6.5
Compliance Certificate
Project Koval Residence
Energy Code: 2015 IECC
Location: Aspen, Colorado
Construction Type: Single-family
Project Type: New Construction
Conditioned Floor Area: 5,115 ft2
Glazing Area 51%
Climate Zone: 7 (9922 HDD)
Permit Date:
Permit Number:
Construction Site: Owner/Agent: Designer/Contractor:
34 Westview Dr
Aspen, CO 81611
Compliance: Passes using UA trade-off
Compliance: 3.2%Better Than Code Maximum UA: 985 Your UA: 953
The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.
Envelope Assemblies
Gross Area Cavity Cont.
Assembly or R-Value R-Value U-Factor UA
Perimeter
Ceiling (R-1): Flat Ceiling or Scissor Truss 3,262 49.0 0.0 0.026 85
EAST WALL W-2: Solid Concrete or Masonry:Interior Insulation 234 24.0 6.0 0.042 7
East Windows (in W-2): Metal Frame with Thermal Break:Single Pane 79 0.320 25
EAST WALL W-3: Wood Frame, 16" o.c. 191 27.0 6.0 0.037 7
EAST WALL W-4: Wood Frame, 16" o.c. 229 27.0 6.0 0.037 7
East Windows (In W-4): Metal Frame with Thermal Break:Single Pane 35 0.320 11
NORTH WALL W-1: Solid Concrete or Masonry 668 24.0 10.0 0.033 22
Wall height: 10.0'
Depth below grade: 5.5'
Insulation depth: 10.0'
NORTH WALL W-2: Solid Concrete or Masonry:Interior Insulation 266 24.0 6.0 0.042 7
North Windows (In W-2): Metal Frame with Thermal Break:Single Pane 92 0.320 29
NORTH WALL W-3: Wood Frame, 16" o.c. 972 27.0 6.0 0.037 11
North Windows (In W-3): Metal Frame with Thermal Break:Single Pane 511 0.320 164
GARAGE DOOR: Solid 160 0.270 43
SOUTH WALL W-3: Wood Frame, 16" o.c. 1,781 27.0 6.0 0.037 19
South Windows (In W-3): Metal Frame with Thermal Break:Single Pane 1,276 0.320 408
WEST WALL W-3: Wood Frame, 16" o.c. 334 27.0 6.0 0.037 ` 10
West Windows (In W-3): Metal Frame with Thermal Break:Single Pane 55 RECEIVED
Project Title: Koval Residence Report d58/2722/21O18
Data filename: Z:\Shared\Projects\Current Projects\18001.00 - 34 Westview Drive\Calculations\Energy Page 1 of 2
Calcs\18001 RESCHECK-updates.rck ASPEN
BUILDING DEPARTMENT
Gross Area Cavity Cont.
Assembly or R-Value R-Value U-Factor UA
Perimeter
BASEMENT FLOOR: Slab-On-Grade:Heated 70 15.0 0.744 52
Insulation depth: 2.2'
Floor over Outside (S-1): All-Wood Joist/Truss:Over Outside Air 101 49.0 0.0 0.021 2
Crawl Wall (W-2 + W-5): Solid Concrete or Masonry 490 0.0 15.0 0.058 26
Wall height: 5.8'
Depth below grade: 2.5'
Insulation depth: 5.5'
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application.The proposed building has been designed to meet the 2015 IECC requirements in
REScheck Version 4.6.5 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
David Denio, PEA 7/27/18
Name-Title Signature Date
RECEIVED
Project Title: Koval Residence Report d58/Q22/1 l 18
Data filename: Z:\Shared\Projects\Current Projects\18001.00 - 34 Westview Drive\Calculations\Energy Page 2 of 2
Calcs\18001 RESCHECK-updates.rck ASPEN
BUILDING DEPARTMENT