ICC-ES Evaluation Report ESR-2053
ICC-ES I (800) 423-6587 I (562) 699-0543 I www.icc-es.org Reissued 07/2018
This report is subject to renewal 07/2020.
DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION
SECTION: 07 30 05—ROOFING FELT AND UNDERLAYMENT
REPORT HOLDER:
GAF
EVALUATION SUBJECT:
VERSASHIELD® FIRE-RESISTANT ROOF DECK PROTECTION AND
VERSASHIELDTM UNDERLAYMENT
ICC ICC ICC
PMG LISTED
II►1•`
"2014 Recipient of Prestigious Western States Seismic Policy Council sus
(WSSPC)Award in Excellence" A Subsidiary of INTERNATIONAL
ODECOU CIL'
ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically
addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. ANSI
There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this ACCREOREB
report, or as to anproduct covered b y the report. ISOfIEC noes
l� 3 ) Ir rroaom Ce0.flcnllon Bony
#1000
Copyright° 2018 ICC Evaluation Service, LLC. All rights reserved.
ICC
521 EVALUATION
SERVICE Most Widely Accepted and Trusted
ICC-ES Evaluation Report ESR-2053
Reissued July 2018
This report is subject to renewal July 2020.
www.icc-es.orq I (800)423-6587 I (562) 699-0543 A Subsidiary of the International Code Council®
DIVISION: 07 00 00—THERMAL AND MOISTURE 4.0 INSTALLATION
PROTECTION
Section: 07 30 05—Roofing Felt and Underlayment 4.1 General:
VersaShield® Fire-Resistant Roof Deck Protection is
REPORT HOLDER: installed in accordance with the requirements of the
applicable code, the manufacturer's published installation
GAF instructions and this report. The manufacturer's published
installation instructions are to be available at the jobsite
EVALUATION SUBJECT: during the installation.
VERSASHIELD® FIRE-RESISTANT ROOF DECK VersaShield® Fire-Resistant Roof Deck Protection is
PROTECTION AND VERSASHIELDTM' UNDERLAYMENT limited to use over spaced or solid sheathing, or over
existing asphalt shingles, wood shakes or wood shingles
1.0 EVALUATION SCOPE installed on spaced or solid sheathing. Prior to application
of the underlayment, the deck surface is to be free of dust
Compliance with the following codes: and dirt, loose nails and other protrusions. Damaged
• 2012,2009 and 2006 International Building Code®(IBC) sheathing is to be replaced.The underlayment is applied at
• 2012, 2009 and 2006 International Residential Code® right angles to the slope of the roof, beginning at the low
(IRC) point of the roof, and is laid with minimum 2-inch (51 mm)
horizontal and 6-inch (152 mm) vertical lapped joints. It is
• 2013 Abu Dhabi International Building Code(ADIBC)1- attached with a sufficient number of nails, having tin caps
tThe ADIBC is based on the 2009 IBC.2009 IBC code sections referenced or 1-inch-diameter (25.4 mm) plastic caps, to hold the
in this report are the same sections In the ADIBC. underlayment in place until the roof covering is applied,
Properties evaluated: except in areas subject to high winds where the
• Physical properties underlayment fastening must comply with the high wind
attachment requirements specified in Section 1507 of the
• Fire classification 2012 IBC or Section R905 of the 2012 IRC. The
2.0 USES underlayment may be bent to a minimum 1/2-inch
(12.7 mm) radius, but is not to be creased. At junctions
VersaShield® Fire-Resistant Roof Deck Protection between the roof deck and vertical surfaces, the
(previously known as VersaShield® Underlayment) is used underlayment is installed a minimum of 3 inches (76 mm)
as an alternative to ASTM D226, Type I or Type II, roofing up the vertical surface.
underlayment specified in Chapter 15 of the IBC and
Chapter 9 of the IRC. In areas of the roof required to have an ice barrier under
When installed in accordance with Section 4.2.1 of this Chapter 15 of the IBC or Chapter 9 of the IRC, a self
report, VersaShield® Fire-Resistant Roof Deck Protection adhesive polymer bitumen sheet, complying with ASTM
can also be used over existing wood shakes or shingles as D1970 or the ICC ES Acceptance Criteria for Self-adhered
an alternative to the covering materials specified in Section Underlayments for Use as Ice Barriers (AC48), is to be
1510.4 of the IBC or Section R907.4 of the IRC. applied. The underlayment is to be applied over the solid
substrate in sufficient courses so that the underlayment
VersaShield® Fire-Resistant Roof Deck Protection is also extends up the roof a distance equal to the distance inside
used as a component of classified roofing assemblies as the exterior wall line of the building that is specified by the
described in Section 4.3,when installed in accordance with applicable code. The underlayment, applied in the field of
this report. the roof, is to completely overlap the ice barrier (severe
3.0 DESCRIPTION climate underlayment) protection a minimum of 2 inches
(51 mm).
VersaShield® Fire-Resistant Roof Deck Protection is
a resin-bound chopped-glass-fiber substrate, coated on Installation of the roof covering can proceed immediately
both sides with a mineral-filled aqueous coating. The following the underlayment application. The underlayment
underlayment has a weight of 15 pounds per 100 square is to be covered by a roof covering within the time set forth
feet(0.73 kg/m2), and is supplied in rolls, in the manufacturer's published installation instructions.
ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed,nor are they to be construed ilk. c QtlfJr1
as an endorsement of the subject of the report or a recommendation for its use.There is no warranty by ICC Evaluation Service,LLC,express or implied,as :aG
to an mdin or other matter in this report,or as to anyproduct covered b y the report. imm�ux
Yl g P1 P OM Men
Copyright 02018 ICC Evaluation Service,LLC.All rights reserved. - Page 1 of 4
ESR-2053 I Most Widely Accepted and Trusted Page 2 of 4
4.2 Reroofing: 5.0 CONDITIONS OF USE
The existing roof must be inspected in accordance with The VersaShield® Fire-Resistant Roof Deck Protection
Section 1510 of the IBC or Section R907 of the IRC. The described in this report, complies with, or is a suitable
new roof covering is installed over the VersaShield® alternative to what is specified in, those codes listed in
Fire-Resistant Roof Deck Protection in accordance with the Section 1.0 of this report, subject to the following
roof covering manufacturer's published installation conditions:
instructions. The new roof covering must be recognized in 5.1 Installation must comply with this report; the
a current ICC-ES evaluation report, and, when applicable, manufacturer's published installation instructions and
the evaluation report must address installation over wood the applicable code. In the event of a conflict between
shake,wood shingle or asphalt shingle roofs. the manufacturer's published installation instructions
4.2.1 Existing Wood Shakes or Shingles: Where the and this report, this report governs.
application of a new roof covering over wood shingle or 5.2 Installation is limited to roofs with a minimum slope of
shake roofs creates a combustible concealed space,
VersaShield® 2:12 (16.67 percent slope) or to the minimum slope
VersaShield Fire-Resistant Roof Deck Protection can be required for the roof covering in accordance with the
used as an alternative to the covering materials specified applicable code,whichever is greater.
in Section 1510.4 of the IBC or Section R907.4 of the IRC.
The underlayment covers the entire existing wood roof. 5.3 Installation is limited to use with roof coverings that do
Battens used for the new roof covering system are not involve hot asphalt or coal-tar pitch.
installed over the underlayment. The underlayment may be 5.4 Installation is limited to use with approved roof
placed under or over counterbattens, spaced a maximum coverings that are mechanically fastened through the
of 24 inches (610 mm) on center. The underlayment is underlayment to the sheathing or rafters.
fastened to the counterbattens with a sufficient number of
nails, having tin caps or 1-inch-diameter(25.4 mm) plastic 5.5 Installation is limited to roofs with ventilated attic
caps, to hold the underlayment in place until the spaces in accordance with the requirements of the
horizontal battens and roof covering are applied. When applicable code.
counterbattens are installed over the underlayment or
when5.6 VersaShield® Fire-Resistant Roof Deck Protection is
counterbattens are not used, the underlayment is
produced in Conover, North Carolina, under a quality
fastened directly to the existing roof covering in the same control program with inspections by ICC-ES.
manner.
4.2.2 Existing Asphalt Shingles: When installed over 6.0 EVIDENCE SUBMITTED
existing asphalt shingles, the underlayment is applied over Data in accordance with the ICC-ES Acceptance Criteria
the existing roof covering and fastened through the for Nonasphaltic Fiberglass-based Roof Underlayment
• shingles to the sheathing with a sufficient number of nails, (AC160), dated January 2000 (editorially revised February
having tin caps or 1-inch-diameter(25.4 mm) plastic caps, 2014).
to hold the underlayment in place until the roof covering is 7.0 IDENTIFICATION
applied.
7.1 Each roll of underlayment bears a label indicating the
4.3 Roof Classification: GAF name and address, the plant identification, the
When installed in accordance with this report, product name, the roll number, and the evaluation
VersaShield® Fire-Resistant Roof Deck Protection can be report number(ESR-2053).
used as an alternative to Exception 2 to Section 1505.2 of 7.2 The report holder's contact information is the
the 2012 and 2009 IBC, the Exception to Sections 1505.2 following:
and 1505.3 of the 2006 IBC, and Section R902.1 of the
IRC; or any roofing assembly having a Class A, B or C roof GAF
classification, without reducing the roof classification. 1 CAMPUS DRIVE
When installed in accordance with Section 4.1 and Table 1 PARSIPPANY, NEW JERSEY 07054
of this report, roofing assemblies incorporating (973) 628-3000
VersaShield® Fire-Resistant Roof Deck Protection have www.gaf.com
the roof classification specified in Table 1. The roof
coverings must be recognized in a current ICC-ES
evaluation report as shown in Table 2.
ESR-2053 I Most Widely Accepted and Trusted Page 3 of 4
TABLE 1—ROOF CLASSIFICATION OF ASSEMBLIES INCORPORATING
VERSASHIELD®FIRE-RESISTANT ROOF DECK PROTECTION
ROOF COVERING2 SUBSTRATE UNDERLAYMENT1 ROOF MAXIMUM
CLASSIFICATION SLOPE
Class A asphalt glass fiber shingle 15/32-inch plywood One layer VersaShield® A Unlimited
Stone coated,steel,direct to deck, 15/32 inch plywood or
0.013-inch thickness(0.330 mm), spaced sheathing One layer VersaShield® A Unlimited
shingles or panels
15 One layer VersaShield®,and
l32ng or one layer Type 30 asphalt A Unlimited
Steel direct to deck,0.013-inch spaced
sheathing
thickness(0.330 mm),shingles or saturated organic felt
panels 75/32 inch plywood or One layer VersaShield® B Unlimited
spaced sheathing
15/32-inch plywood or One layer VersaShield® A Unlimited
spaced sheathing
Steel over battens,0.013-inch Existing wood shakes or
thickness(0.330 mm),shingles or shingles installed over Two layers VersaShield® A Unlimited
panels spaced or solid sheathing
Existing wood shakes or
shinales installs ri nvar one layer VersaShield® B Unlimited
spaced or solid sheathing
feel,0.016-inch thickness(0.406 15/32 inch plywood or
mm),panels or standing seam spaced sheathing One layer VersaShield® A Unlimited
s
—Onc layer Vcrse£,hield®,....1 —
15/32-inch plywood or
spaced sheathing one layer Type 30 asphalt A Unlimited
saturated organic felt
Existing wood shakes or
shingles installed over Two layers of VersaShield® A Unlimited
Copper,0.016-inch thickness(0.406 spaced or solid sheathing
mm),shingles or panels 15/32-inch plywood or
spaced sheathing One layer VersaShield® B Unlimited
Existing wood shakes or
shingles installed over One layer of VersaShield® B Unlimited
spaced or solid sheathing
75/32 inch plywood or Two layers VersaShield® A Unlimited
spaced sheathing
Aluminum,0.018-inch(0.457 mm), 15/32-inch plywood or One layer VersaShield® B Unlimited
shingles,panels,or standing seam spaced sheathing
system
Existing wood shakes or
shingles installed over One layer VersaShield® B Unlimited
spaced or solid sheathing
15/32-inch plywood Two layers VersaShield® A 11/2:12
TPO,CSM,CPA,EPDM,cap sheet, 15/32 inch plywood, ® 1
or modified bitumen single-ply insulation Two layers VersaShield® A 1 /2:12
membranes
15/32-inch plywood One layer VersaShield® B 11/2:12
15/32-inch plywood Two layers VersaShield® A 2:12
PVC single-ply membrane 15/32 inch plywood, Two layers VersaShield® A 11/2:12
insulation
15/32-inch plywood One layer VersaShield® B 11/2:12
For SI: 1 inch=25.4 mm.
1Underlayment must be installed in accordance with Section 4.0 of this report.
2Roof coverings must be recognized in a current ICC-ES evaluation report.The roof covering must comply with the Class A or B flame-spread
requirements of UL790(ASTM E108),as applicable to the systems defined in this table.
ESR-2053 I Most Widely Accepted and Trusted Page 4 of 4
TABLE 2—EVALUATION REPORT CROSS-REFERENCE
COMPANY ICC-ES EVALUATION RECOGNIZED PRODUCT
REPORT NUMBER
Carlisle Syntec ESR-1463 EPDM,PVCand TPO Single-Ply Membranes
Delta Building Products,Ltd. ESR-1790 Aluminum and Steel Roofing Shingles and Panels
Decra Roofing Systems,Inc. ESR-1754 Decra Villa Tile,Decra Shake XDM and Decra Shingle XDTM
Steel Roofing Panels
Decra Roofing Systems,Inc. ESR-2901 Steel Roofing Panels:Decra Tile,Decra Shake,Decra Shingle
Plus
Gerard,Allmet,Storm Loc,Energy Loc,Armor,Eco Loc,Rof
Gerard Roofing Technologies ESR-1188 Loc,Storm Loc,and Stormtile Brands of Guardian,Granite
Ridge,Diplomat and Diplomat Plus Steel Roofing Panels
Steel Roofing Panels:Tile;Shake;Canyon Shake;Barrel
Gerard Roofing Technologies ESR-1491 Vault;NB Tile in the following brands:Allmet,Armor,Eco Loc,
Energy Loc,Gerard,Roof Loc,Stone Loc,Storm Loc,
Stormtile
Firestone Building Products Company,LLC ESR-2831 Firestone UltraPlyT"'TPO and TPO XR Singly Ply Roofing
Membranes
Ideal Roofing Company Ltd. ESR-3101 Wakefield Bridge(26 gage)Steel Panels and Wakefield
Bridge(29 gage)Steel Panels
Ideal Roofing Company Ltd. ESR-3100 HF-16 and HF-20.25 Roof Panels
DaVinci Roofscapes, LLC ESR 2119 DaVinci Slate,DaVinci Shake,Bellaforte Shake and Bellaforte
Slate Roof Shingles
Feroof Co.,Ltd. gSR-3331 Steel Roofing Panels:Veneto I,
Veneto II,Rio,Rio EZ,Diva,Wood,Zissen and Slate
Ensoltis Green Hybrid Roofing LLC ESR-2904 Ensoltis Savanna S Roof Tile
Custom-Bilt Metals ESR-2048 Custom-Bilt Standing Seam Metal Roof:CB-150 and SL-1750
2001 Company, Inc.,dba Kelly Company-2001 Inc. ESR-3185 2001 Company Inc.EPDM,PVC and TPO Single Ply Roofing
Membranes
Roser Co.,Ltd ESR-1763 Roser Steel Roofing Panels:Spany,Roser Bond,Rowood,
Tuscany Tile and Stonewood Shake
Berridge Manufacturing Company ESR-3486 Berridge Cee-Lock and Zee-Lock Standing Seam Roof Panels
1The aluminum panels are limited to Class B roof covering assemblies.