Loading...
HomeMy WebLinkAboutMaster Permit.623 S Monarch St.0005-2022-BREP (7) DR I MVO R D A LYT E An NA Inthrtniss Company DATE: February 24, 2022 Affidavit for Building Permit DALYTE shall be the subcontractor responsible for the following scope(s) of work: Furnish and Install window system to hit .28 system L-value per City of.Aspen requirement. and shall furnish and/or install said materials subject to the aforementioned scope above, and shall furnish any and all drawings, submittals, and/or testing in accordance with the procurement of all related building permits in question. Project: lspen Mountain I )vvnhotnes Project Location: 623 South Monarch Street, :Aspen, CO 81611 Drawing Submittals (Latest Revision): dated [ 2/4/2022 Testing and/or Certification (Latest Revision): dated [ 2/272°22 ] Signature u O C,4 Affidavit from window/door manufacturer /v ' I verifying that custom package shipped to project matches the approved specifications provided for review is required to be provided to the building department prior to inspection. LYTE 303.296.9696 DalyteUSA.com 290 E 56th Ave., Denver, CO 80216 RECEIVED D�V -1dt 02/25/2022 ASPEN FppCOotaaR""� BUILDING DEPARTMENT 0 February 2, 2022 Dan Hoch DALYTE 290 E 56th Ave Denver, CO 80216 Subject: Window Wall Simulations(Project NS-03626-1 RD2) The simulation of your Window Wall has-been completed per NFRC test methods: ANSI/NFRC 100 and ANSI/NFRC 200. UL Laboratory Canada Inc. is an NFRC-accredited simulation laboratory. The results of your simulation of a 2000mm x 2000mm Window Wall was as follows: Insulating Glass Unit Overall Product This sheet ID Option Name U Factor represents W7 COG ID Spacer Grid Grid Size SHGC VT CR multiple test W/m2-K Btu/hr-ft2-F attempts. The I 1 2a_SM -Arg90-LO#4 SB70#29F 1 TS-D N 1.50 0.26 0.23 0.51 52 I - 2 2b_SM_591062-Arg90-IIrVII-Arg90-56/0#S 2 i5-u N 1.0L U.15 V.LU V.9U it applicant is 3 3a_SM S670#2-Arg90 LOF#4 1 TS-D N 1.45 0.26 0.23 0.51 54 representing that the highlighted 4 3b SM SB70#2-Arg90-CINIT-Arg90-5670#5 2 rs o N 1.00 0.16 0.20 0.40 so result is the one they are using. "SM: Technoform M The above window was constructed with the follow glazing options: Insulating Glass Unit U factor Glass 1 Gap 1 Glass 2 Gap 2 Glass 3 ID Name SHGC VT Emissivities Type mm mm gas Type mm mm gas Type mm W/m2-K Btu/hr-ft2-F 1 S&7062-Arg90-LOF#4 0.018(#2), Solarban' 1 5.7 12.53 1 Arg90 I LOF 6.0 1.10 0.19 0.26 0.60 0.157(#4) 70 2 5870#2-Arg90-CIrVIT-Arg90- 0.018(#2), Solarban' Solarban' 5.7 12.53 Arg90 Clear 5.7 12.53 Arg90 5.7 0.67 0.12 0.23 0.47 5870#5 0.018(P5) 70 70 `•IGDB V 83 is the current version used for this project "'Please note that the results could change if an update of the glass library(IGDB)is required and that the options used for this R&D are modified in a later version. If you have any questions or concerns, please feel free to contact me. Best regards, Sandrine Benjamin-Auger NFRC Certified Simulator, Thermal Evaluation TORONTO MONTREAI. TELFORD 7 Underwriters Road 1320 Lionel-Boulet BNd Haiestleid 2 Toronto Varennes Tegord ON M1R 3A9 QC J3X 1P7 TF7 4QH 'N ul.corn/bwldingenveiope Canada Canada United Kingdom T-+1 866.937 3852 1- +1.855 353 2532 T +44 1952 586.580 E BuildingEnvelope@ul corn E BulldingEnvelope@ul corn c.BuildingEnvelopeEurope@uI corn p} Iv IA RECEIVED 02/23/2022 J 02/25/2022 FORGOOMMAIICE ASPEN l imP BUILDING DEPARTMENT