HomeMy WebLinkAboutagenda.hpc.20230614AGENDA
ASPEN HISTORIC PRESERVATION
COMMISSION
June 14, 2023
4:30 PM, City Council Chambers -
3rd Floor
427 Rio Grande Place
Aspen, CO 81611
I.ROLL CALL
II.MINUTES
II.A Draft Minutes - 5/10/23 & 5/24/23
III.PUBLIC COMMENTS
IV.COMMISSIONER MEMBER COMMENTS
V.DISCLOSURE OF CONFLICT OF INTEREST
VI.PROJECT MONITORING
VI.A Project monitor list
VII.STAFF COMMENTS
VIII.CERTIFICATE OF NO NEGATIVE EFFECT ISSUED
IX.CALL UP REPORTS
X.SUBMIT PUBLIC NOTICE FOR AGENDA ITEMS
XI.OLD BUSINESS
XI.A
205 W. Main Street- Minor Development and Relocation, PUBLIC HEARING CONTINUED
FROM APRIL 26, 2023
minutes.hpc.20230510_DRAFT.docx
minutes.hpc.20230524_DRAFT.docx
PROJECT MONITORING.doc
Memo_205 W. Main.pdf
Resolution_205 W. Main.pdf
1
1
XII.NEW BUSINESS
XII.A Presentation of past preservation work- Kirsten Armstrong
XIII.ADJOURN
XIV.NEXT RESOLUTION NUMBER
Exhibit A.1_HP Guidelines Criteria_Staff Findings.pdf
Exhibit A.2_Relocation Criteria_Staff Findings.pdf
Exhibit A.3_GMQS Criteria_Staff Findings.pdf
Exhibit B_New information in response to April 26th hearing.pdf
Exhibit C_Previously Submitted Application.pdf
Exhibit D_April 26 HPC minutes.pdf
TYPICAL PROCEEDING FORMAT FOR ALL PUBLIC HEARINGS
(1 Hour, 10 Minutes for each Major Agenda Item)
1. Declaration of Conflicts of Interest (at beginning of agenda)
2. Presentation of proof of legal notice (at beginning of agenda)
3. Applicant presentation (20 minutes)
4. Board questions and clarifications of applicant (5 minutes)
5. Staff presentation (5 minutes)
6. Board questions and clarifications of staff (5 minutes)
7. Public comments (5 minutes total, or 3 minutes/ person or as determined by the Chair)
8. Close public comment portion of hearing
9. Applicant rebuttal/clarification (5 minutes)
10. Staff rebuttal/clarification (5 minutes)
End of fact finding. Chairperson identifies the issues to be discussed.
11. Deliberation by the commission and findings based on criteria commences. No further
input from applicant or staff unless invited by the Chair. Staff may ask to be recognized if
there is a factual error to be corrected. If the item is to be continued, the Chair may
provide a summary of areas to be restudied at their discretion, but the applicant is not to
re-start discussion of the case or the board’s direction. (20 minutes)
12. Motion
Updated: November 15, 2021
2
2
REGULAR MEETING HISTORIC PRESERVATION COMMISSION MAY 10TH, 2023
Chairperson Thompson opened the regular meeting of the Aspen Historic Preservation Commission at
4:30pm.
Commissioners in attendance: Peter Fornell, Roger Moyer, Jodi Surfas, Barb Pitchford, Jeffery Halferty
and Kara Thompson.
Staff present:
Amy Simon, Planning Director
Kirsten Armstrong, Principal Planner Historic Preservation
Kate Johnson, Assistant City Attorney
Mike Sear, Deputy City Clerk
MINUTES: Mr. Halferty moved to approve the minutes from 4/12/23. Ms. Thompson seconded. Roll call
vote:Mr. Fornell, yes; Mr. Moyer, yes; Ms. Surfas, abstained; Ms. Pitchford, abstained; Mr. Halferty, yes;
Ms. Thompson, yes. 4-0; motion passes.
PUBLIC COMMENTS: None
COMMISSION MEMBER COMMENTS: Mr. Halferty commented about the site visit to 835 W. Main. He
thanked everyone for organizing the tour of the cabin. He was in support of the property’s National
Landmark designation.
Ms. Thompson said she had listened in to the Ski Town Forum meeting and said it was interesting to
hear what other towns are doing.
Ms. Pitchford had visited John Doyle’s studio and said that he has a 3D model of town and that after
seeing it she wanted to suggest that applicants provide 3D models with their applications and
presentations to HPC. She said that it would be very helpful in understanding the mass and scale of
projects. Ms. Simon reviewed the submittal requirements for applications and said that they could
potentially make them more specific.
There was then some discussion on the potential for additional and more descriptive models of future
projects.
Mr. Moyer commented on the large size of the addition on the Pan Abode on the other side of the alley
from Ann Mullins house. He said that it was a good example of making sure that HPC sees more context
on mass and scale when reviewing projects.
Ms. Simon said that they could organize a van tour of previous HPC projects for the next meeting.
Ms. Johnson reminded the commissioners that they are allowed by Code to request any additional
materials from applicants that they feel would help them in their review and decision making.
DISCLOSURE OF CONFLICTS OF INTEREST: None.
PROJECT MONITORING: Before getting into project monitoring, Ms. Simon wanted to take a moment to
introduce Ms. Kirsten Armstrong, the new Principal Planner for Historic Preservation. Ms. Armstrong
then went over her education and background. The HPC members welcomed her to Aspen.
3
REGULAR MEETING HISTORIC PRESERVATION COMMISSION MAY 10TH, 2023
Ms. Simon mentioned that Ms. Sanzone’s projects would have to be reassigned, as she had resigned
from HPC.
STAFF COMMENTS: Ms. Simon commented on the background of the Ski Town Forum and topics that
were discussed at the most recent meeting. She also reviewed preservation efforts by other ski towns
(Crested Butte & Breckinridge) in the State.
There was then some discussion about 100% affordable housing projects located on historic sites.
835 W. Main Street – National Register Referral Comment
Staff Presentation:Kirsten Armstrong, Principal Planner Historic Preservation
Ms. Armstrong began by introducing the property and the National Register Referral Comment process.
She then went over some of the history and characteristics of the cabin design and the surrounding
property. She showed several pictures of the cabin and lot, while describing the design. She went on to
describe the criterion being used for the nomination and how the property meets Criterion C. Next, she
described the options that HPC have, noting that staff recommends that the nomination meets the
NRHP eligibility criteria requirements.
There was some discussion and questions about the current roof and its potential future replacement.
All commissioners were in support of the nomination. Ms. Thompson signed the Referral form.
CERTIFICATE OF NO NEGATIVE EFFECT: None.
CALL UP REPORTS: None.
SUBMIT PUBLIC NOTICE FOR AGENDA ITEMS: Ms. Johnson said that she reviewed public notice, and
that notice was provided per the code for the agenda item.
OLD BUSINESS: 214 W. Bleeker Street – Minor Development, Relocation and Variation Review –
PUBLIC HEARING CONTINUED FROM APRIL 12th.
Ms. Thompson asked about the difference between a variation and a variance. Ms. Johnson said that in
the Land Use Code there are certain things that a variance is required for, for example a setback
variance. Other things in the code allow a variation to be granted, like a variation to a guideline. Ms.
Simon said the variances usually based on a hardship and the normally go to the Board of Adjustment.
Applicant Presentation:Jason Ro – Ro Rockett Design
Mr. Ro began by reviewing items that they had restudied on the project since the last meeting on this.
These included the house lift, material conditions of the roof, and more study of the historic shed, it’s
restoration and ways to give it more significance. He noted that all this would lead into the discussion of
a square footage bonus request.
He then showed a few historic photos of the house, highlighting some changes over time. He noted that
the original house was sitting slightly above grade and that over time the grade had risen and built up.
Next, he showed a current picture of the house, noting that the porch is now only about one step (6-7
inches) above grade. He also showed a proposed rendering of the project that with the lifting of the
4
REGULAR MEETING HISTORIC PRESERVATION COMMISSION MAY 10TH, 2023
house would allow them to restore the original sandstone base and get multiple steps up to the porch.
He described a few of their proposed materials on the historic and non-historic portions of the house.
He then presented a picture of a similar project they had completed a few years ago. He went on to
present and describe the proposed elevations, highlighting a few features. Next, he described the roof
differentiation between the historic asset and existing non-historic addition that they are attempting to
achieve, including different roof materials. He reviewed the proposed move of the historic shed to the
north to better separate it for the non-historic addition. As they were calculating the FAR, they found
that the size of the shed exceeded the non-exempt shed allowance that the code allows for. He noted
that, built into their FAR bonus request, is the reduction of a non-historic shed on the side of the
addition to the allowable 32 square feet and the FAR that is required to cover the historic shed. He
showed a few pictures of the historic shed and noted some if its features and the current damage to the
structure. In closing, he said that they hoped that all this shows an earnest effort to improve the historic
asset and shed, in order to earn the 175 square foot FAR bonus they are requesting.
Mr. Fornell asked when they thought the non-historic addition was built. Ms. Simon said it was around
1990.
Ms. Thompson said from the shed elevations, it seemed like it was elevated about 6 inches on a slab and
wondered if this was done in the past. Ms. Simon said that the 6 inches is the minimum building code
requirement and that the shed is currently buried in the ground and moving it will allow it to be set on
more level ground.
Ms. Pitchford asked about the process of removing the chimney before raising the house and then how
it would be re-built. Mr. Ro said that the strategy is to remove as much of it in one piece as possible. It
would be documented with pictures and then rebuild it once the house has been raised and restabilized.
Ms. Simon noted that the chimney restoration was a condition in the resolution.
Ms. Thompson asked if the intent is to lift the house and move it, or just to lift it straight up. Mr. Ro said
the idea will be to lift it in place.
Ms. Pitchford asked about the existing fence on the property. Mr. Ro showed some pictures of the
existing fencing and described the proposal of reducing the height of some of the fencing.
There was some discussion of paint color and questioning of why everything nowadays is painted white.
Staff Presentation:Amy Simon - Planning Director
Ms. Simon started with some history of the project and application. The original idea was just to lift the
structure and build a basement under it. After looking at the project more carefully with Mr. Ro a few
things came up. These included the historic foundation with steps onto the porch which has been lost
and also the historic shed. She showed some pictures of another project that Mr. Ro had worked on,
pointing out some of the great features of the restoration. She noted that everything from the last
meeting’s discussion has been addressed in a very cooperative way by the applicant.
She then reviewed the seven conditions listed in the resolution. These included:
1. The financial security deposit of $45,000.
2. The preservation of the historic exterior materials.
3. Documentation of the chimney and stone foundation in order to authentically reconstruct them.
4. Setback variations for the primary structures.
5
REGULAR MEETING HISTORIC PRESERVATION COMMISSION MAY 10TH, 2023
5. Floor Area Bonus of 175 square feet to be granted.
6. No stormwater features to be visible in the landscape in the front of the structure.
7. The shed roof must be with corrugated metal or wood shingle if the pitch allows.
Mr. Moyer asked if there was a requirement for the foundation to be one or two cement blocks higher
than grade. Ms. Simon said that building code requires 6 inches of clearance off the ground of any wood
materials. Referencing the historic shed, Mr. Moyer suggested that they require one block or two above
grade. He also suggested that this should be a topic of discussion for HPC in relation to future projects.
Ms. Simon mentioned she had forgotten to include the normal condition of approval, requiring a 12”
maintenance border at the perimeter of the historic resources.
Ms. Thompson asked about a landscape plan. Mr. Ro said the owner is looking to do next to nothing in
terms of landscaping. It would mostly be a grass lawn.
Mr. Fornell asked Ms. Simon, that if the addition was done in 1990, how come it goes into two separate
setbacks. Ms. Simon said she didn’t look back at the original approval, but since it went through HPC
back then, they could have given setback variations, as the house is where it is.
Ms. Thompson asked that since the shed is being moved from where it has been for a very long time, is
there a discussion to be had about moving it so it is not exactly on the property line to allow for drainage
and better maintenance. Ms. Simon said it was not something she had discussed with the applicant, but
it is something that could be open to HPC’s input. Ms. Simon agreed that it should be moved enough to
be safe from snowplows, but not so much that it takes away from its historical relationship to the alley.
Mr. Fornell said he liked the shed’s orientation at the property line having been there historically but
would be open to any suggestions.
PUBLIC COMMENT: None.
BOARD DISCUSSION: Ms. Thompson started by suggesting that when the historic shed is moved that it
be placed 6 inches off the property line. Mr. Fornell said he supported that suggestion.
Ms. Thompson noted that they had discussed the relocation criteria in the last meeting, and all generally
agreed that the lift and place of the structure was acceptable. She said that while setback variations are
not a favorite of the board, the shed would still be further away from setbacks than a garage could be,
so she was ok with the proposed variances. She also believed that with the restoration of the shed that
the applicant had earned the floor area bonus.
Mr. Fornell wanted to clarify that the bonus was not really an addition of floor area, but rather to
account for the different calculation. Mr. Ro said yes that the lifting of the house created a different
calculation.
Ms. Johnson noted that the floor area bonus in the resolution was requesting 125 square feet and it was
represented at the meeting that it was a 175 square foot request and wanted to clarify the difference.
Ms. Simon said that it was an update sent to the board on Tuesday. Ms. Simon said that she had also
updated the rear yard setback in the conditions of approval to 4.5 feet from 5 feet, to note the
suggestion from the board and could also add the condition of a 12-inch maintenance border. Ms.
Thompson said yes to adding that condition.
6
REGULAR MEETING HISTORIC PRESERVATION COMMISSION MAY 10TH, 2023
MOTION: Ms. Thompson moved to approve the next resolution in the series with the edits and
additions that had been made. Mr. Halferty seconded.Roll call vote:Mr. Fornell, yes; Mr. Moyer, yes;
Ms. Surfas, yes; Ms. Pitchford, yes; Mr. Halferty, yes; Ms. Thompson, yes.6-0 vote, motion passes.
Mr. Fornell and Ms. Pitchford were assigned as project monitors for this item.
Mr. Moyer asked if the 12-inch maintenance border was a fixed number. Ms. Simon said that it was not
and could be made bigger. Mr. Moyer said he thought it should be at least 2 feet if not 3 feet. He knew it
was a lot, but it was needed and better than 12 inches. There was some more discussion about how
wide a maintenance border should be to protect the house.
NEW BUSINESS: HPC Awards Selection
Staff Presentation:Amy Simon - Planning Director
Ms. Simon started by reviewing the history of the awards in general and went over the various HPC
Awards and some of their history. She then went over the projects up for awards this year and some
details of each. These included:
Resnick Center for Herbert Bayer Studies.
Boettcher Building - Designation and Rehabilitation
The Wheeler Opera House Restoration
105 East Hallam Street
208 East Main Street
533 West Hallam Street
The commissioners discussed each project. Ms. Thompson said she would support the Wheeler Opera
House Restoration. There was then some discussion about the details of the work completed there. All
commissioners were in favor of awarding the Wheeler Opera House Restoration.
ADJOURN: Ms. Thompson motioned to adjourn the regular meeting. Mr. Fornell seconded. All in favor;
motion passes.
____________________
Mike Sear, Deputy City Clerk
7
REGULAR MEETING HISTORIC PRESERVATION COMMISSION MAY 24TH, 2023
Chairperson Thompson opened the regular meeting of the Aspen Historic Preservation Commission at
4:31 PM.
Commissioners in attendance: Peter Fornell, Roger Moyer, Barb Pitchford, Jeffery Halferty and Kara
Thompson. Jodi Surfas arrived at 4:34 PM.
Staff present:
Amy Simon, Planning Director
Kirsten Armstrong, Principal Planner Historic Preservation
James R. True, City Attorney
Cindy Klob, Records Manager
MINUTES: Ms. Thompson moved to approve the minutes from 4/26/23. Mr. Halferty seconded. Roll call
vote:Mr. Fornell, yes; Ms. Pitchford, abstained; Mr. Halferty, yes; Mr. Moyer, yes; Ms. Thompson, yes
for a total of four to zero (4-0) vote; motion passes.
PUBLIC COMMENTS: None
COMMISSION MEMBER COMMENTS: Ms. Pitchford inquired about the status of the interview to fill the
available board positions. Mr. True replied Council is reviewing the candidates and estimated the
decision will be made in the next couple of Council meetings.
DISCLOSURE OF CONFLICTS OF INTEREST: None.
PROJECT MONITORING:
227 E Bleeker St.
Ms. Simon stated Mr. Halferty is monitoring the project at 227 E Bleeker St which is currently under
construction. She noted the Victorian resource was obscured by asbestos shingles. She stated she and
Mr. Halferty have reviewed a number of project monitoring changes and visited the site a few times
because things were found during the demolition phase. They received a request to add solar panels to
the project. The addition of the solar panels on the new addition were approved but she stated the
board has historically hesitated to place them on the historic resource due to the visual impact. They
asked the applicant to present the requested change to the board.
Ms. Simon stated staff supports the request to add panels to the historic resource because they will not
be visible from the street, and it supports sustainability.
She stated she and Mr. Halferty are asking the board to provide direction regarding the request.
Ms. Kim Raymond, Kim Raymond Architecture + Interiors, noted there are letters of support in the
packet. She also submitted another letter of support at the meeting from Mr. Antony Cullwick, Koru
Limited (refer to Exhibit D in the meeting agenda).
She discussed the applicant and his desire to make this project as sustainable as possible. His goal is to
get a LEED Platinum rating for this historic resource and to be able to use this project as a model of
historic preservation projects while moving forward with energy efficiencies. She also noted this project
aligns with the City’s goal for homes to be all electric in the future.
8
REGULAR MEETING HISTORIC PRESERVATION COMMISSION MAY 24TH, 2023
Ms. Raymond then displayed a picture of the house and pointed out the flat roof with a parapet on the
back of the structure. She displayed a drawing showing the proposed location of the panels on the flat
roof and the adjoining gabled roof as compared to the street in front of the house. She pointed She
stated the panels on the historic structure would provide the more than half of the energy production of
all the panels installed on both the historic structure and new addition.
Ms. Raymond then displayed a sun path solar chart depicting the solar exposure in the winter, fall and
spring, and the summer.
Shen then displayed 3D renderings of views of the roof, front, and east street level to show the
proposed panels will not be visible from the street.
She closed asking the board for their support.
Ms. Thompson asked Mr. Halferty if he supported the request. He responded he initially was not
supportive of it because historically the board did not approve of solar panels on historic resources. And
he wants to ensure the historic structure could be returned to its prior state before the panels.
Ms. Thompson asked if what type of material will be replacing the roof. Ms. Raymond responded it will
be replaced with weathered wood asphalt shingle.
Ms. Thompson asked how they would be attaching the panels. Ms. Raymond stated they wanted to first
get approval before spending a lot of time on the method to attach them. She noted other larger cities
such as New York City are now allowing solar panels on historic structures.
Ms. Surfas asked if they considered installing the Tesla shingles on the new addition. Ms. Raymond
responded they looked into using them and they are not yet available. Ms. Simon stated she also heard
they are not yet available.
Ms. Pitchford asked if the panels were not on the historic resource how much would the production be
diminished. Ms. Raymond responded the panels on the historic structure provide the majority of the
energy production.
Mr. Fornell asked what the useful life of the panels. Mr. Raymond responded she did not know.
Mr. Fornell referenced a historic cabin at 311 Park Ave which has solar shingles installed on it and asked
if they considered something like that. Ms. Raymond responded she was not aware of all the options
that were considered.
Ms. Thompson stated she does not have any issue with the proposed panels and feels it’s great to have
them installed. She suggested having a structural engineer write a letter verifying the resource can
support the panels without damaging the historic resources and have staff approve of the attachment
method.
Ms. Pitchford asked staff if there were any other historic resources with solar panels installed within the
city. Ms. Simon responded the only other resource with approval for panels is the Wheeler Opera
House. She the board approved very visible panels to be installed and then the City decided not to install
the system for now.
Mr. Halferty asked if the power would be used for snowmelt or to just power the home. Ms. Raymond
responded it would power the house. She added the percentage of snowmelt is quite small and did not
require the panels to be approved.
9
REGULAR MEETING HISTORIC PRESERVATION COMMISSION MAY 24TH, 2023
Mr. Halferty asked if they considered a pedestal system for the panels. Ms. Raymond responded there is
no room available on the property.
Mr. Fornell and Mr. Moyer both stated they support the proposed panels on the historic resource. Ms.
Surfas state she also supported the panels. Ms. Pitchford did not support it. Ms. Thompson noted a
majority of the board supports the addition of the panels.
Multiple board members asked for staff to look into adding something to the guidelines to cover solar
panels on historic structures.
Ms. Thompson asked that nothing be attached to the house for maintenance access. Ms. Raymond
confirmed there were no plans to attach anything to the house to maintain the panels.
Ms. Simon asked the applicant to submit a change order that will be reviewed by staff and the project
monitor.
STAFF COMMENTS:
Ms. Simon stated the HPC Awards will be at the June 6
th Council meeting. They will be awarding the
Wheeler Opera House.
Ms. Simon noted social media posts about the process of the Berger Cabin to be placed on the National
Register of Historic Places and the beginning of restoration of the Elks Building. It will be the same team
that restored the Wheeler Opera House and will be a multi-year project.
CERTIFICATE OF NO NEGATIVE EFFECT: Ms. Simon stated one had been signed for the Golden Horn
Building for some repairs and a replacement of a ramp with a lift.
CALL UP REPORTS: None.
SUBMIT PUBLIC NOTICE FOR AGENDA ITEMS: None.
OLD BUSINESS: 205 W. Main St – Minor Development and Relocation Review – CONTINUE PUBLIC
HEARING TO JUNE 14TH.
Ms. Thompson moved to continue the hearing to June 14th and was seconded by Mr. Moyer.
Mr. Moyer asked for a session to discuss solar panels and vehicle charging systems and stations. Ms.
Simon responded the new code requires new homes to have them in the interior of the structure.
Roll call vote:Ms. Surfas, yes; Mr. Fornell, yes; Ms. Pitchford, yes; Mr. Moyer, yes; Mr. Halferty, yes; Ms.
Thompson, yes for a six to zero (6-0) vote, motion passes.
NEW BUSINESS: Mobile Tour of HPC projects
The regular meeting was then adjourned, and the tour will be opened as a work session.
10
REGULAR MEETING HISTORIC PRESERVATION COMMISSION MAY 24TH, 2023
ADJOURN: Ms. Thompson motioned to adjourn the regular meeting. Ms. Pitchford seconded.
Roll call vote:Mr. Moyer, yes; Mr. Halferty, yes; Ms. Pitchford, yes; Mr. Fornell, yes; Ms. Surfas, yes; Ms.
Thompson, yes for a six to zero (6-0) vote, motion passes.
________________________
Cindy Klob, Deputy City Clerk
11
HPC PROJECT MONITORS -projects in bold are permitted or under construction
6/8/2023
Kara Thompson 931 Gibson
300 E. Hyman
201 E. Main
333 W. Bleeker
234 W. Francis
Skier’s Chalet Steakhouse
423 N. Second
135 E. Cooper
101 W. Main (Molly Gibson Lodge)
720 E. Hyman
304 E. Hopkins
930 King
312 W. Hyman
520 E. Cooper
Jeff Halferty 533 W. Hallam
110 W. Main, Hotel Aspen
134 E. Bleeker
300 E. Hyman
434 E. Cooper, Bidwell
414-420 E. Cooper, Red Onion/JAS
517 E. Hopkins
Lift 1 corridor ski lift support structure
227 E. Bleeker
211 W. Hopkins
211 W. Main
204 S. Galena
215 E. Hallam
500 E. Durant
413 E. Main
Roger Moyer 300 W. Main
227 E. Main
110 Neale
517 E. Hopkins
Skier’s Chalet Lodge
202 E. Main
305-307 S. Mill, Grey Lady
320 E. Hyman (Wheeler Opera House, solar panels)
611 W. Main
132 W. Hopkins
500 E. Durant
Jodi Surfas 202 E. Main
305-307 S. Mill, Grey Lady
320 E. Hyman (Wheeler Opera House, solar panels)
611 W. Main
602 E. Hyman
Peter Fornell 304 E. Hopkins
930 King
233 W. Bleeker
214 W. Bleeker
Barb Pitchford 121 W. Bleeker
312 W. Hyman
132 W. Hopkins
214 W. Bleeker
Need to assign: 209 E. Bleeker, 125 W. Main, Lift One Park
12
MEMORANDUM
TO: Aspen Historic Preservation Commission
FROM: Amy Simon, Planning Director
RE: 205 W. Main Street- Minor Development and Relocation, PUBLIC HEARING
CONTINUED FROM APRIL 26, 2023
MEETING DATE: June 14, 2023
Applicant/Owner:
Conservation Housing Partners LLC, c/o
Michael Brown
605 W. Main Street, Suite 2, Aspen, CO
81611
Representatives:
Haas Land Planning, LLC
420 E. Main Street, Suite 220
Aspen, CO 81711
Location:
Street Address:
205 W. Main Street
Legal Description:
Lots H and I and the East fifteen (15’)
feet of Lot G, Block 52, City and Townsite
of Aspen, Pitkin County, Colorado
Parcel Identification Number:
PID# 2735-124-54-003
Current Zoning & Use:
Mixed Use (MU), Single Family Home
with voluntary Accessory Dwelling Unit
Proposed Zoning & Use:
Mixed Use (MU), 100% affordable
housing
Summary: The applicant requests Minor Development and
Relocation approval on a landmark designated site containing
a Victorian era home. The subject resource is to be reduced
to its historic footprint, moved northeast onto a full basement,
and surrounded by new landscape materials. Non-historic
shed and trash enclosures towards the rear of the site are to
be demolished. HPC approval of work directly affecting the
exterior of the historic home and the site immediately around
it is a pre-requisite for Administrative Review of a not yet
submitted land use application to convert the existing home to
affordable housing and to develop other structures containing
affordable housing on the property. This is the first application
pursuant to recent code amendments adopted by Council to
simplify and advance the creation of more affordable housing
units in the City. Staff recommends approval subject to the
conditions listed in the proposed resolution.
Figure 1: Subject Property | 205 W. Main Street
205
Figure 2: Subject Property | View from Main
13
Page | 2
REQUEST OF THE HISTORIC PRESERVATION COMMISSION:
Pursuant to Growth Management Section 26.470.050.D.3 of the Municipal Code, which establishes a
review process when a historic property is to be developed with affordable housing as the sole use, the
Applicant is requesting the following approvals from the Historic Preservation Commission:
• Minor Development (Section 26.415.070.D) for exterior alterations to the historic home and
landscape on the site, and to remove non-historic additions that have been made to the property,
in the form of an expansion on the west side of the historic house, a prefabricated shed and modest
trash enclosures.
• Relocation (Section 26.415.090) to move the historic resource onto a new basement.
Following HPC review, Administrative Review will be conducted for determination that the new construction
on the site is in compliance with Chapter 26.410, Residential Design Standards; Chapter 26.470, Growth
Management; Chapter 26.515, Transportation and Parking Management; Chapter 26.540, Certificates of
Affordable Housing Credit, and Chapter 26.710 for the applicable Zone District. The new construction must
meet all dimensional standards prescribed within the Mixed-Use (MU) zone district. In addition to those
reviews, the Historic Preservation Principal Planner and the Chair of the Historic Preservation Commission,
or their assign, must jointly determine compliance with non-flexible design standards listed in the Municipal
Code.
BACKGROUND:
205 W. Main Street is a landmarked property located within the Mixed-Use (MU) zone district and the Main
Street Historic District. The property contains a Victorian-era single-family dwelling and non-historic shed
structures on a 7,500 sq. ft. lot. The dwelling was constructed circa 1890 and moved to its current location
in 1949, where the Chisholm family made it their long-time home. The original design and materials of the
resource are substantially intact, including wood siding and shingles in the gables, a porch with original
decorative features, and a dormer. Much of the outdoor vegetation appears consistent with the historic
landscape from the time the cottage was relocated.
UPDATES IN RESPONSE TO HPC DIRECTION AT THE APRIL 26, 2023 HEARING
The public hearing for this review was opened on April 26th. After a full presentation and discussion of the
project, HPC voted 3-2 to continue to a later date and to request more information on existing building
placement in the surrounding historic district to help the board analyze the appropriateness of the
relocation request. The applicant was also asked to restudy the positioning of a lightwell proposed at the
southwest corner of the house and a request to include a preservation plan in the conditions of approval
was made.
The applicant has submitted new information which is attached as Exhibit B. The previous submittal is
Exhibit C. Minutes from the April 26th hearing are found at Exhibit D. The context study that has been
provided is very helpful as a factual analysis of development patterns in the district. The applicant has
reinforced that there is variety in building positioning throughout the district and that their proposed siting
is both consistent with other development and beneficial to the public in that at least two faces of the
structure will be preserved with an unobstructed view to passersby. Staff continues to find that setting the
resource at the southeast corner and ensuring its preservation as a free-standing building with no additions
is an excellent outcome for preservation goals.
In addition to providing additional response to relocation related design guidelines, the applicant has
provided information to resolve a number of the conditions of approval proposed by staff in April.
Remaining items to be addressed in permit and construction are included in the attached Resolution.
14
Page | 3
STAFF COMMENTS:
A site plan is provided in the application indicating the general concept for building layout. All new
structures must be fully detached and sit at least 10 feet away from the historic home. HPC’s purview is
restricted to the criteria and guidelines addressed in the exhibits to this memo.
The applicant proposes to place the historic resource prominently at a street intersection, free-standing
and exposed to view/public enjoyment on all sides, and in a traditional landscaped setting abutted with
grass, planting beds and outdoor living space. Public right-of-way on the east side of the lot is to be
converted from head in parking back to a lawn with grass and street trees, which will restore a historic
landscape condition that has been lost for many years.
Staff supports the plan to re-position the Victorian. It is not original to this site and there is not a strong
historic context on this block-face. The building will have high public visibility and will be among a small
group of Victorian homes preserved in Aspen with no addition.
As required by this review process, the applicant must remove non-historic construction and proposes to
remove an addition to the house that is well documented to have been made after the house was moved
to this site as well as an overframed section of roof on the rear shed pitch. There are no other alterations
planned for the resource and also no obvious restoration opportunities, though staff will conduct a site visit
with the applicant team. It appears that the front door may not be original and if so, could be replaced with
a more period appropriate design.
The applicant also proposes demolition of a clearly non-historic shed and trash enclosures.
This project meets numerous historic preservation and community objectives and will restore and activate
a resource in a prominent location. Staff finds the project complies with all criteria and guidelines.
DRC REFERRAL COMMENTS:
The application was referred out to Engineering and Parks. Conditions of approval recommended by those
agencies are included in the Resolution.
RECOMMENDATION
Staff recommends the Historic Preservation Commission (HPC) approve this application as described in
the proposed Resolution.
ATTACHMENTS:
Resolution #___, Series of 2023
Exhibit A.1 – HP Guidelines Criteria Staff Findings
Exhibit A.2 – Relocation Criteria Staff Findings
Exhibit A.3 – Growth Management Review Criteria Staff Findings
Exhibit B – New information in response to April 26th hearing
Exhibit C – Previously submitted application
Exhibit D – April 26th HPC minutes
15
HPC Resolution # XX, Series of 2023
Page 1 of 3
RESOLUTION #__, SERIES OF 2023
A RESOLUTION OF THE ASPEN HISTORIC PRESERVATION COMMISSION (HPC)
GRANTING MINOR DEVELOPMENT AND RELOCATION APPROVAL FOR THE
PROPERTY LOCATED AT 205 W. MAIN STREET, LEGALLY DESCRIBED AS LOTS H AND
I AND THE EAST FIFTEEN FEET OF LOT G, BLOCK 51, CITY AND TOWNSITE OF ASPEN,
COUNTY OF PITKIN, STATE OF COLORADO
PARCEL ID: 2737-124-54-003
WHEREAS, the Applicant, Conservation Housing Partners LLC, represented by Haas Land
Planning, LLC, has requested HPC approval for Minor Development and Relocation; the first of two review
steps necessary to develop affordable housing as the only use on the property located at 205 W. Main Street
pursuant to Municipal Code Section 26.470.090.D.3, Review of 100% Affordable Housing Development
on Designated Sites Containing a Historic Resource; and,
WHEREAS, Section 26.415.070 of the Municipal Code states that “no building or structure shall
be erected, constructed, enlarged, altered, repaired, relocated or improved involving a designated historic
property or district until plans or sufficient information have been submitted to the Community
Development Director and approved in accordance with the procedures established for their review;” and,
WHEREAS, for Minor Development Review, the HPC must review the application, a staff
analysis report and the evidence presented at a hearing to determine the project’s conformance with the
City of Aspen Historic Preservation Design Guidelines per Section 26.415.070.C of the Municipal Code
and other applicable Code Sections. The HPC may approve, disapprove, approve with conditions or
continue the application to obtain additional information necessary to make a decision to approve or deny;
and
WHEREAS, for approval of Relocation, the application shall meet the requirements of Aspen
Municipal Code Section 26.415.090.C, Relocation of a Designated Property; and,
WHEREAS, Community Development Department staff reviewed the application for compliance
with applicable review standards and recommended approval with conditions; and
WHEREAS, on April 26, 2023, HPC considered the application, the staff memo and public
comment and continued the public hearing for more information. On June 14, 2023, HPC found the
proposal consistent with the review standards and granted approval with conditions by a vote of X to X (X-
X).
NOW, THEREFORE, BE IT RESOLVED:
That HPC hereby approves Minor Development and Relocation as the first of two review steps necessary
to develop affordable housing as the only use on the property located at 205 W. Main Street. Before
advancing this approval to building permit, the applicant must also secure administrative approval as
described at Municipal Code Section 26.470.090.D.3.
Section 1: HPC Conditions of Approval
1. The front walkway to the historic resource is to be gray concrete, brick or rectilinear flagstone.
Prior to building permit submittal a sample of paving materials is to be reviewed and approved by
staff and monitor.
16
HPC Resolution # XX, Series of 2023
Page 2 of 3
2. Prior to building permit submittal a final landscape plan shall be reviewed and approved by staff
and monitor.
3. The non-historic west addition is approved to be removed from the historic structure and the void
infilled with clapboards.
4. The pre-fabricated shed and trash enclosures are approved to be removed from the site.
5. The applicant has committed to retain and repair all exterior materials based on field inspection
with historic preservation staff, and at the same inspection must work with historic preservation
staff to identify any reasonable restoration actions that can be accomplished. The treatment of
exterior features on the resource will be clearly depicted on a “preservation plan” sheet that is
required to be part of the building permit submittal.
6. Stormwater management cannot be fully detailed until after the additional allowances on this site
are verified, however the site plan represents no visible stormwater features on the subject site
surrounding the resource, which is a condition of approval. A fully developed stormwater
management plan shall be provided as part of building permit submittal.
7. Any new fence between the historic resource and the street shall be no more than forty-two inches
(42”) in height and shall have no less than a solid to void ratio of fifty-percent (50%). The design
for any proposed fence shall be reviewed and approved by staff and monitor prior to building permit
submittal.
8. Once mechanical systems are designed, provide elevations and a roof plan of the historic resource
identifying the location of all vents, flues, FDC and strobe, and mechanical equipment for review
and approval by staff and monitor prior to building permit submittal. Avoid damage to historic
materials and visually intrusive locations.
9. Provide cut sheets of all exterior light fixtures for review and approval by staff and monitor prior
to building permit submittal.
10. To relocate the house on the site, the Applicant shall provide a financial security deposit of $30,000
at the time of permit issuance. The submission shall include details on how the relocation will
occur. Upon making a determination that the home was successfully placed on the new foundation,
staff shall return the deposit to the Applicant.
Section 2: Referral Agency Conditions of Approval
1. The Administrative Review for the full development of the site must include the provision of
a compliant Transportation Impact Assessment (TIA).
2. At building permit the following information will be required:
Utility Plan
• When a site plan is finalized with the additional structures, the site plan will need to
show where a transformer to support the development will be placed. A single phase
transformer with a 5x5 vault may be needed. Provide an easement to accommodate the
transformer with 3' clear zones surrounding the sides and back of the transformer and
10' clear in the front. Alternatively work with COA Electric Dept to determine
available capacity in the transformer in the alley to the west for the full built out site.
• The water main for this property is on the north side of Main St. A new water service
line for this property will require CDOT approval and most likely overnight work. For
the full build out if fire suppression is needed a new line will most likely be required. It
appears the water service line was installed in 1981 and may be due for an upgrade.
URMP
• Applicant will be required to follow the requirements of a major development within the
Urban Runoff Management Plan.
3. A floating sidewalk design will be required along First Street where the existing cottonwoods
are located.
4. The entire grass area along First Street will need to be irrigated throughout the project.
17
HPC Resolution # XX, Series of 2023
Page 3 of 3
5. Proposed trees specifying species and diameter along First Street south of the walk to the house
will need to be approved by the City Forester.
6. Street trees species and diameter along Main will need to be approved by City Forester.
7. Irrigation of ROW will be required to have a separate zone for trees.
Section 3: Existing Deed Restriction
A voluntary Deed-Restriction encumbers the basement of the historic resource (Reception No. 376974). As
part of the Administrative Review, the Applicant shall work with staff to memorialize an approval to release
the deed-restriction.
Section 4: Material Representations
All material representations and commitments made by the Applicant pursuant to the development proposal
approvals as herein awarded, whether in public hearing or documentation presented before the Community
Development Department, the Historic Preservation Commission, or the Aspen City Council are hereby
incorporated in such plan development approvals and the same shall be complied with as if fully set forth
herein, unless amended by other specific conditions or an authorized authority.
Section 5: Existing Litigation
This Resolution shall not affect any existing litigation and shall not operate as an abatement of any action
or proceeding now pending under or by virtue of the ordinances repealed or amended as herein provided,
and the same shall be conducted and concluded under such prior ordinances.
Section 6: Severability
If any section, subsection, sentence, clause, phrase, or portion of this Resolution is for any reason held
invalid or unconstitutional in a court of competent jurisdiction, such portion shall be deemed a separate,
distinct and independent provision and shall not affect the validity of the remaining portions thereof.
APPROVED BY THE COMMISSION at its regular meeting on the 14th day of June, 2023.
Approved as to Form: Approved as to Content:
__________________________________ ___________________________________
Katharine Johnson, Assistant City Attorney Kara Thompson, Chair
ATTEST:
___________________________________
Mike Sear, Deputy City Clerk
18
Exhibit A.1
Historic Preservation Design Guidelines
Staff Findings
Page 1 of 7
26.415.070. Development involving designated historic property or property within a historic
district.
No building, structure or landscape shall be erected, constructed, enlarged, altered, repaired, relocated
or improved involving a designated historic property or a property located within a Historic District until
plans or sufficient information have been submitted to the Community Development Director and
approved in accordance with the procedures established for their review. An application for a building
permit cannot be submitted without a development order.
26.415.070.C Minor Development
3. The procedures for the review of minor development projects are as follows:
b) Staff shall review the submittal material and prepare a report that analyzes the project's
conformance with the design guidelines and other applicable Land Use Code sections.
This report will be transmitted to the HPC with relevant information on the proposed project
and a recommendation to approve, disapprove or approve with conditions and the reasons
for the recommendation. The HPC will review the application, the report and the evidence
presented at the hearing to determine the project's conformance with the City Historic
Preservation Design Guidelines.
c) The HPC shall approve, disapprove, approve with conditions or continue the application
to obtain additional information necessary to make a decision to approve or deny. If the
application is approved, the HPC shall issue a certificate of appropriateness and the
Community Development Director shall issue a development order.
To the extent that this review process requires removal of non-historic additions, the following criteria
apply:
26.415.080. Demolition of designated historic properties or properties within a historic district.
It is the intent of this Chapter to preserve the historic and architectural resources that have demonstrated
significance to the community. Consequently, no demolition of properties designated on the Aspen
Inventory of Historic Landmark Site and Structures or properties within a Historic District will be allowed
unless approved by the HPC in accordance with the standards set forth in this Section.
4. The HPC shall review the application, the staff report and hear evidence presented by the property
owners, parties of interest and members of the general public to determine if the standards for
demolition approval have been met. Demolition shall be approved if it is demonstrated that the
application meets any one of the following criteria:
a) The property has been determined by the City to be an imminent hazard to public safety
and the owner/applicant is unable to make the needed repairs in a timely manner,
b) The structure is not structurally sound despite evidence of the owner's efforts to properly
maintain the structure,
c) The structure cannot practically be moved to another appropriate location in Aspen or
d) No documentation exists to support or demonstrate that the property has historic,
architectural, archaeological, engineering or cultural significance and
19
Exhibit A.1
Historic Preservation Design Guidelines
Staff Findings
Page 2 of 7
Additionally, for approval to demolish, all of the following criteria must be met:
a) The structure does not contribute to the significance of the parcel or Historic District in
which it is located and
b) The loss of the building, structure or object would not adversely affect the integrity of the
Historic District or its historic, architectural or aesthetic relationship to adjacent designated
properties and
c) Demolition of the structure will be inconsequential to the historic preservation needs of the
area.
Relevant Historic Preservation Design Guidelines for review of this application:
1.1 All projects shall respect the historic development pattern or context of the block,
neighborhood or district.
• Building footprint and location should reinforce the traditional patterns of the neighborhood.
• Allow for some porosity on a site. In a residential project, setback to setback development is
typically uncharacteristic of the historic context. Do not design a project which leaves no useful
open space visible from the street.
1.5 Maintain the historic hierarchy of spaces.
• Reflect the established progression of public to private spaces from the public sidewalk to a semi-
public walkway, to a semi private entry feature, to private spaces.
1.6 Provide a simple walkway running perpendicular from the street to the front entry on
residential projects.
• Meandering walkways are not allowed, except where it is needed to avoid a tree or is typical of
the period of significance.
• Use paving materials that are similar to those used historically for the building style and install
them in the manner that they would have been used historically. For example on an Aspen
Victorian landmark set flagstone pavers in sand, rather than in concrete. Light grey concrete,
brick or red sandstone are appropriate private walkway materials for most landmarks.
• The width of a new entry sidewalk should generally be three feet or less for residential properties.
A wider sidewalk may be appropriate for an AspenModern property.
1.7 Provide positive open space within a project site.
• Ensure that open space on site is meaningful and consolidated into a few large spaces rather
than many small unusable areas.
• Open space should be designed to support and complement the historic building.
1.8 Consider stormwater quality needs early in the design process.
• When included in the initial planning for a project, stormwater quality facilities can be better
integrated into the proposal. All landscape plans presented for HPC review must include at least
a preliminary representation of the stormwater design. A more detailed design must be reviewed
and approved by Planning and Engineering prior to building permit submittal.
20
Exhibit A.1
Historic Preservation Design Guidelines
Staff Findings
Page 3 of 7
• Site designs and stormwater management should provide positive drainage away from the
historic landmark, preserve the use of natural drainage and treatment systems of the site, reduce
the generation of additional stormwater runoff, and increase infiltration into the ground.
Stormwater facilities and conveyances located in front of a landmark should have minimal visual
impact when viewed from the public right of way.
• Refer to City Engineering for additional guidance and requirements.
1.12 Provide an appropriate context for historic structures. See diagram.
• Simplicity and restraint are required. Do not overplant a site, or install a landscape which is
overtextured or overly complex in relationship to the historic resource, particularly in Zone A. In
Zone A, new planting shall be species that were used historically or species of similar attributes.
• In areas immediately adjacent to the landmark, Zone A and Zone B, plants up 42” in height, sod,
and low shrubs are often appropriate.
• Contemporary planting, walls and other features are
not appropriate in Zone A. A more contemporary
landscape may surround new development or be
located in the rear of the property, in Zone C.
• Do not cover areas which were historically unpaved
with hard surfaces, except for a limited patio where
appropriate.
• Where residential structures are being adapted to
commercial use, proposals to alter the landscape will
be considered on a case-by-case basis. The
residential nature of the building must be honored.
• In the case of a historic landmark lot split, careful
consideration should be given so as not to over plant
either property, or remove all evidence of the
landscape characteristics from before the property
was divided.
• Contemporary landscapes that highlight an
AspenModern architectural style are encouraged.
2.1 Preserve original building materials.
• Do not remove siding that is in good condition or that can be repaired in place.
• Masonry features that define the overall historic character, such as walls, cornices, pediments,
steps and foundations, should be preserved.
• Avoid rebuilding a major portion of an exterior wall that could be repaired in place.
Reconstruction may result in a building which no longer retains its historic integrity.
• Original AspenModern materials may be replaced in kind if it has been determined that the
weathering detracts from the original design intent or philosoph
3.1 Preserve the functional and decorative features of a historic window.
21
Exhibit A.1
Historic Preservation Design Guidelines
Staff Findings
Page 4 of 7
• Features important to the character of a window include its frame, sash, muntins/mullions, sills,
heads, jambs, moldings, operations, and groupings of windows.
• Repair frames and sashes rather than replacing them.
• Preserve the original glass. If original Victorian era glass is broken, consider using restoration
glass for the repair.
3.2 Preserve the position, number, and arrangement of historic windows in a building wall.
• Enclosing a historic window is inappropriate.
• Do not change the size of an original window opening.
4.1 Preserve historically significant doors.
• Maintain features important to the character of a historic doorway. These include the door, door
frame, screen door, threshold, glass panes, paneling, hardware, detailing, transoms and flanking
sidelights.
• Do not change the position and function of original front doors and primary entrances.
• If a secondary entrance must be sealed shut, any work that is done must be reversible so that
the door can be used at a later time, if necessary. Also, keep the door in place, in its historic
position.
• Previously enclosed original doors should be reopened when possible.
5.1 Preserve an original porch or balcony.
• Replace missing posts and railings when necessary. Match the original proportions, material and
spacing of balusters.
• Expanding the size of a historic porch or balcony is inappropriate.
5.5 If new steps are to be added, construct them out of the same primary materials used on the
original, and design them to be in scale with the porch or balcony.
• Steps should be located in the original location.
• Step width should relate to the scale of entry doors, spacing between posts, depth of deck, etc.
• Brick, red sandstone, grey concrete, or wood are appropriate materials for steps.
5.6 Avoid adding handrails or guardrails where they did not exist historically, particularly where
visible from the street.
• If handrails or guardrails are needed according to building code, keep their design simple in
character and different from the historic detailing on the porch or balcony.
6.1 Preserve significant architectural features.
• Repair only those features that are deteriorated.
• Patch, piece-in, splice, or consolidate to repair the existing materials, using recognized
preservation methods whenever possible.
• On AspenModern properties, repair is preferred, however, it may be more important to preserve
the integrity of the original design intent, such as crisp edges, rather than to retain heavily
deteriorated materia
22
Exhibit A.1
Historic Preservation Design Guidelines
Staff Findings
Page 5 of 7
7.1 Preserve the original form of a roof.
• Do not alter the angle of a historic roof. Preserve the orientation and slope of the roof as seen from
the street.
• Retain and repair original and decorative roof detailing.
• Where the original roof form has been altered, consider restoration.
7.2 Preserve the original eave depth.
• Overhangs contribute to the scale and detailing of a historic resource.
• AspenModern properties typically have very deep or extremely minimal overhangs that are key
character defining features of the architectural style.
10.2 A more recent addition that is not historically significant may be removed.
• For Aspen Victorian properties, HPC generally relies on the 1904 Sanborn Fire Insurance maps to
determine which portions of a building are historically significant and must be preserved.
• HPC may insist on the removal of non-historic construction that is considered to be detrimental to
the historic resource in any case when preservation benefits or variations are being approved.
12.4 Minimize the visual impacts of utilitarian areas, such as mechanical equipment and trash
storage.
• Place mechanical equipment on the ground where it can be screened.
• Mechanical equipment may only be mounted on a building on an alley façade.
• Rooftop mechanical equipment or vents must be grouped together to minimize their visual
impact. Where rooftop units are visible, it may be appropriate to provide screening with materials
that are compatible with those of the building itself. Use the smallest, low profile units available
for the purpose.
• Window air conditioning units are not allowed.
• Minimize the visual impacts of utility connections and service boxes. Group them in a discrete
location. Use pedestals when possible, rather than mounting on a historic building.
• Paint mechanical equipment in a neutral color to minimize their appearance by blending with
their backgrounds
• In general, mechanical equipment should be vented through the roof, rather than a wall, in a
manner that has the least visual impact possible.
• Avoid surface mounted conduit on historic structures.
Staff Findings: Guidelines applicable to this review address Site Planning and Landscape, Building
Materials, Windows, Doors, Porches, Architectural Details, Roofs and Building Relocation.
To develop this property as multi-family housing, the applicant proposes to site the historic resource
prominently at a street intersection, free-standing and exposed to view/public enjoyment on all sides, and
in a traditional landscaped setting abutted with grass, planting beds and outdoor living space. The only
work before HPC is review of the relocation and siting of the historic structure, its immediate landscape,
and any exterior alterations to the resource. New construction is to be reviewed via an administrative
23
Exhibit A.1
Historic Preservation Design Guidelines
Staff Findings
Page 6 of 7
process. The site plan provided in the HPC packet indicates that new development will be fully detached
from the historic resource and placed to the rear and side of it.
Staff finds the amount of unbuilt area in the form of front and side setbacks creates the site porosity called
for in the design guidelines. In addition, the public right-of-way on the east side of the lot is to be
converted from head in parking to a lawn with grass and street trees, which will restore a historic
landscape condition that has been lost for many years.
The historic home was moved to this site from the corner of N. Monarch and E. Hallam in 1949. It is
unclear when a porch was added to the rear of the house, then enclosed, perhaps when a small addition
was made at the southwest corner of the building once the home was placed at 205 W. Main. The
progression of the alterations is illustrated below. The applicant intends to demolish the non-historic
construction on the west and retain the former porch, which may be historic materials.
The applicant also proposes to demolish a group of small sheds on the site (shown below) that are pre-
fabricated or roughly constructed and not related to the history of the subject resource, therefore have
no significance and meet all criteria for removal. Staff supports this action.
1904 Sanborn Map
of house in original
location
1979 drawing by Assessor.
Note open porch at rear
and one story side addition
Current plan. Rear porch was enclosed at
some time. Applicant plans to remove all
of the side addition
24
Exhibit A.1
Historic Preservation Design Guidelines
Staff Findings
Page 7 of 7
Making no addition to the historic structure is in keeping with historic preservation goals to minimize
alterations directly affecting to a historic resource, and is a threshold requirement for this review process.
There are limited instances where this has been achieved in Aspen. The plan to program the historic
resource as mandatory occupancy housing will also activate the historic resource in a way that HPC has
valued in past discussions. No exterior changes, other than repair and restoration where possible, are
proposed. Conditions of approval related to finalized preservation plans and sensitive placement of
necessary features such as vents, flues and exterior lights are included in the resolution.
Staff finds that the relevant design guidelines and criteria are met, with conditions, and
recommends HPC grant approval.
25
Exhibit A.2
Relocation
Staff Findings
Page 1 of 3
26.415.090.C. Standards for the relocation of designated properties. Relocation for a building,
structure or object will be approved if it is determined that it meets any one of the following standards:
1. It is considered a noncontributing element of a historic district and its relocation will not affect the
character of the historic district; or
2. It does not contribute to the overall character of the historic district or parcel on which it is located
and its relocation will not have an adverse impact on the Historic District or property; or
3. The owner has obtained a certificate of economic hardship; or
4. The relocation activity is demonstrated to be an acceptable preservation method given the
character and integrity of the building, structure or object and its move will not adversely affect the
integrity of the Historic District in which it was originally located or diminish the historic, architectural
or aesthetic relationships of adjacent designated properties; and
Additionally, for approval to relocate all of the following criteria must be met:
1. It has been determined that the building, structure or object is capable of withstanding the physical
impacts of relocation;
2. An appropriate receiving site has been identified; and
3. An acceptable plan has been submitted providing for the safe relocation, repair and preservation
of the building, structure or object including the provision of the necessary financial security.
Relevant Historic Preservation Design Guidelines for review of this application:
9.2 Proposals to relocate a building will be considered on a case-by-case basis.
• In general, on-site relocation has less of an impact on individual landmark structures than those
in a historic district.
• In a district, where numerous adjacent historic structures may exist, the way that buildings were
placed on the site historically, and the open yards visible from the street are characteristics that
should be respected in new development.
• Provide a figure ground study of the surrounding parcels to demonstrate the effects of a building
relocation.
• In some cases, the historic significance of the structure, the context of the site, the construction
technique, and the architectural style may make on-site relocation too impactful to be appropriate.
It must be demonstrated that on-site relocation is the best preservation alternative in order for
approval to be granted.
• If relocation would result in the need to reconstruct a substantial area of the original exterior
surface of the building above grade, it is not an appropriate preservation option.
9.3 Site a relocated structure in a position similar to its historic orientation.
• It must face the same direction and have a relatively similar setback. In general, a forward
movement, rather than a lateral movement is preferred. HPC will consider setback variations
where appropriate.
• A primary structure may not be moved to the rear of the parcel to accommodate a new building in
front of it.
26
Exhibit A.2
Relocation
Staff Findings
Page 2 of 3
• Be aware of potential restrictions against locating buildings too close to mature trees. Consult with
the City Forester early in the design process. Do not relocate a building so that it becomes
obscured by trees.
9.4 Position a relocated structure at its historic elevation above grade.
• Raising the finished floor of the building slightly above its original elevation is acceptable if needed
to address drainage issues. A substantial change in position relative to grade is inappropriate.
• Avoid making design decisions that require code related alterations which could have been
avoided. In particular, consider how the relationship to grade could result in non-historic
guardrails, etc.
9.5 A new foundation shall appear similar in design and materials to the historic foundation.
• On modest structures, a simple foundation is appropriate. Constructing a stone foundation on a
miner’s cottage where there is no evidence that one existed historically is out of character and is
not allowed.
• Exposed concrete or painted metal flashing are generally appropriate.
• Where a stone or brick foundation existed historically, it must be replicated, ideally using stone
salvaged from the original foundation as a veneer. The replacement must be similar in the cut of
the stone and design of the mortar joints.
• New AspenModern foundations shall be handled on a case by case basis to ensure preservation
of the design intent.
9.6 Minimize the visual impact of lightwells.
• The size of any lightwell that faces a street should be minimized.
• Lightwells must be placed so that they are not immediately adjacent to character defining features,
such as front porches.
• Lightwells must be protected with a flat grate, rather than a railing or may not be visible from a
street.
• Lightwells that face a street must abut the building foundation and generally may not “float” in the
landscape except where they are screened, or on an AspenModern site.
9.7 All relocations of designated structures shall be performed by contractors who specialize in moving
historic buildings, or can document adequate experience in successfully relocating such buildings.
• The specific methodology to be used in relocating the structure must be approved by the HPC.
• During the relocation process, panels must be mounted on the exterior of the building to protect
existing openings and historic glass. Special care shall be taken to keep from damaging door and
window frames and sashes in the process of covering the openings. Significant architectural
details may need to be removed and securely stored until restoration.
• The structure is expected to be stored on its original site during the construction process.
Proposals for temporary storage on a different parcel will be considered on a case by case basis
and may require special conditions of approval.
• A historic resource may not be relocated outside of the City of Aspen.
Staff Findings: The applicant proposes relocation of the existing structure to the front and east setback
lines. No variations are requested. The home was relocated to this property from the West End around
1949. Because the house wasn’t built on this property, it’s positioning on the subject lot can be adjusted
without impact to individual integrity, however the patterns of the historic district should be considered.
That said, the subject site was only minimally developed in the Victorian era (see lots G, H, and I below)
in 1893. By 1904 even these structures were gone. The only original historic house remaining on this
blockface is 211 W. Main, pictured on Lot F below. Staff finds that the proposed re-positioning of 205 W.
Main does not diminish any historic relationships between adjacent properties.
27
Exhibit A.2
Relocation
Staff Findings
Page 3 of 3
Staff finds that the proposed on-site relocation of this home is an appropriate preservation outcome
because it will provide separation between the historic resource and any future new construction, and will
improve the visibility of the historic structure.
The proposed relationship to grade is consistent with the current condition and appears to expose only a
minimal foundation. The above grade foundation will be clad with painted metal, a typical detail approved
by HPC.
The applicant has restudied and greatly reduced the size of individual lightwells proposed on the west side
of the resource, even improving the existing condition seen below.
The applicant has provided their architect’s preliminary finding that the historic resource can be safely
relocated. Standard conditions of approval regarding confirmation of building movability from an engineer,
specific relocation techniques proposed by the housemover, and a security to be held by the City during
construction are included in the resolution.
Staff finds that the relocation criteria are met and recommends HPC grant approval.
28
Exhibit A.3
GMQS
Staff Findings
26.470.090.D.3 Review of 100% Affordable Housing Development on Designated Sites
Containing a Historic Resource where the Historic Resource is fully detached from all new
construction, and all non-historic additions are to be removed, and no new addition will be made
to the historic resource, and all new construction taller than one story is distanced at least 10 feet
from the historic resource on all sides.
Development of these properties, when the use is 100% affordable housing, shall be subject to a
one step review by the Historic Preservation Commission, for compliance with Section
26.415.070.C, Certificate of appropriateness for a minor development (demolition of non-historic
additions and all work directly affecting the historic resource); and Section 26.415.090 Relocation
of designated historic properties. All City of Aspen Historic Preservation Design Guidelines
applicable to work affecting the historic resource shall apply in addition to the following criteria:
a. HPC may not deny Relocation, but shall determine a siting for the historic structure that
best meets the City of Aspen Historic Preservation Design Guidelines while
accommodating the allowed development rights for the property. A Conceptual site plan
representing the full project must be provided to assist in this review.
Staff Response: As stated in Exhibit A.2, staff finds the proposed relocation to highlight
the resource on the property. Preserving the home as a detached structure with no
additions is a successful outcome. The home is not original to the property and therefore
its current setbacks do not tell the story of the Victorian era development of the building
or Main Street.
b. HPC may grant approval for the historic resource only to be located in the side, rear and
front setbacks per Section 26.415.110.C.1.a, Variations. New construction is not permitted
to be located in a setback. HPC may allow the new structure to provide no less than six
(6) feet as the minimum distance requirement between buildings per Section
26.415.110.C.1.b. Where the historic resource is one story in height, this reduction is only
permissible if the new construction permitted to be within six (6) feet of the resource is one
story in height for at least ten (10) feet in depth.
Staff Response: No setback variations are requested.
c. The application must include a detailed summary, in consultation with the Historic
Preservation Officer, of all necessary repairs to historic fabric that will be completed during
construction including exterior materials, doors and windows. The summary must also
identify all opportunities to restore an element of the historic resource to an earlier
condition that can be documented through photographs or physical inspection. HPC will
prioritize and require up to three (3) of these to be completed during construction.
Examples include: re-opening of an enclosed porch, restoration of the original design of a
street facing window, and restoration of missing details such as decorative porch trim.
Staff Response: To date, no specific restoration opportunities have been identified as
the resource appears to have few alterations. All historic materials will be identified with
staff and are required to be preserved as a condition of approval. An inspection of the
interior of the structure after finishes are removed will be required and may identify
additional restoration opportunities, up to three of which may be required.
29
Exhibit A.3
GMQS
Staff Findings
d. As applicable, site development shall be designed so that:
1. A front walkway to the historic resource shall be no wider than the minimum
requirement for accessibility, shall run directly from the street to the door unless
necessary to avoid a preserved tree, and shall be gray concrete, brick, rectilinear stone
or flagstone, to be determined by HPC.
2. Stormwater facilities and conveyances shall be demonstrated to fully integrated with
the surrounding landscape palette when viewed from the public right of way.
3. The perimeter of the historic resource shall be entirely bordered by a gravel or small
diameter rock planting strip one (1) foot in width to protect from the impacts of
landscape planting and watering. No plant material around the historic resource shall
have an identified mature height taller than forty-two inches (42”), other than one shrub
or tree, placed with the mature size of the species in mind. No hardscape, other than
a front walkway, shall be permitted in street-facing yards around the historic resource.
4. Perimeter fences which are considered part of the historic significance of a site shall
be retained and repaired and cannot be moved, removed, or inappropriately altered.
5. Any new fence between the historic resource and the street shall be no more than
forty-two inches (42”) in height and shall have no less than a solid to void ratio of fifty-
percent (50%).
Staff Response: Staff finds these criteria met with conditions included in the restolution,
such as a condition of approval that the front walkway shall be gray concrete, brick or
rectilinear stone.
Though additional stormwater design development is needed, the application represents
no visible stormwater features surrounding the resource, which is a condition of approval.
The application includes the required maintenance border.
The application does not represent a fence, and no historically significant fence exists on
the property. If a fence is proposed when this project is developed, the design must be
reviewed and approved by staff and monitor and any new fence between the historic
resource and the street shall be no more than forty-two inches (42”) in height and shall
have no less than a solid to void ratio of fifty-percent (50%).
30
June 2, 2023
Aspen Historic Preservation Commission
c/o Amy Simon, Planning Director
Aspen County Community Development
427 Rio Grande Place, Main Floor
Aspen, CO 81611
RE: Update and Addendum to Proposed On-Site Relocation Application for 205
West Main Street, Aspen, CO
Dear Amy and Historic Preservation Commissioners:
Per staff’s direction, the Applicant provides below responses to applicable HPC
Design Guidelines and standards, as well as the staff-recommended conditions
received in the April 26th, 2023, meeting. The attached plans are referenced in and
supplement the narratives provided below.
A. Provide additional information for Guideline 1.1:
All projects shall respect the historic development pattern or context of the block,
neighborhood or district.
1. Building footprint and location should reinforce the traditional patterns of the
neighborhood.
2. Allow for some porosity on a site. In a residential project, setback to setback
development is typically uncharacteristic of the historic context. Do not design a
project which leaves no useful open space visible from the street.
B. Applicant Response to Guideline 1.1:
In properly balancing the City’s goals relative to historic preservation and the
development of affordable housing, the Applicant proposes to locate the restored
historic resource prominently at the junction of the minimum front and side yard
setback lines closest to the street intersection. Once the non-historic additions
have been removed, the relocated and restored resource will be free-standing
and exposed to view/public enjoyment on all sides. A simple, traditional
landscaped setting will be provided with gravel around building foundation
exposures, which exposures will be clad in metal to be reviewed and approved
by staff and monitor. Grass, planting beds, and outdoor living spaces will abut
AAS
AND
LANNING, LLC
420 E. MAIN STREET, SUITE 220, ASPEN, CO 81611
(970) 309-2773 – MITCH@HLPASPEN.COM
• 420 E. MAIN STREET, SUITE 220 • ASPEN, COLORADO • 81611 •
• PHONE: (970) 309-2773 • MITCH@HLPASPEN.COM •
31
205 W. Main Street – On-Site Relocation Page 2
the gravel foundation surround. The walkway to the front porch and entrance
will be a simple straight form of approximately 3-feet in width.
At the request of the HPC, the Applicant team has completed an extensive study
of front yard setbacks on the subject block, on the neighboring properties of the
Mixed-Use Zone District, and throughout the Main Street Historic District
(MSHD). The study included an on-the-ground survey of building locations
along with a review of the GIS survey. This provided the team an accurate
understanding of the observed setback from the Main Street curbline, as property
lines are not easily identifiable in real world conditions. The findings of these
studies have illustrated a variable pattern along the length of Main Street and no
single “urban corridor” type setback created due to uniform facades. Of
particular observance, buildings on corner lots without grandfathered head-in
parking are located close to the right-of-way and holding the corner of the lots. In
the instance of the head-in-parking, these buildings tend to be as close to the
right of way beyond the depth of the parking areas as practicable.
Furthermore, the setbacks context study clearly demonstrates that the proposed
relocation provides a setback that is highly consistent with that of the adjacent
historic resource. The two building faces, exclusive of front porches, would have
a distance from the curbline that is only 4-inches different, with the adjacent
resource being 29’-10” from the curbline and the proposed relocation setting the
subject asset’s building face at 29’-6” from the curbline. Zooming a bit further
out into the site context, the study shows that the proposed relocation complies
fully with the City’s codified “Build-to Requirement” (Code Section
26.410.030.B.3, Residential Design Standards) by placing 100% of the historic
building façade within 5-feet of the minimum yard setback line along both street
frontages. In fact, as the context study shows, the proposed relocation is within 2-
or 3-feet of the average front yard setback for all existing structures along the
south side of Main Street’s 100-400 blocks. That average setback line would run
more or less through the center of the relocated asset’s front porch. In short, the
proposed relocation plan is absolutely consistent with the surrounding
neighborhood and Main Street Historic District context, and through that lens, a
far more appropriate building placement than the location to which this asset
was originally relocated.
The proposed on-site relocation respects the historic development pattern and
context of the block and the MSHD. The asset is not original to the site or to the
MSHD, and its location on the property has diminished its potential contribution
to the District. That is, while on a corner lot, the asset is a relatively small
structure that has resided too far back from the Main Street sidewalk to provide
any real prominence, detracting from the maximum potential contribution the
asset can and should make to the historic character of the District. The proposed
relocation will reinforce the traditional patterns of street-front orientation in the
MSHD by enhancing the orientations of the front porch and primary facades
32
205 W. Main Street – On-Site Relocation Page 3
relative to and parallel to Main Street and South First Street. Despite its small
size, the move of approximately fifteen feet to the northeast will appropriately
increase the contribution of this resource by having it prominently anchor the
corner.
It is understood that the proposed relocation is intended to accommodate a
future application for the development of separate affordable housing structures
while harmonizing with the character of the MSHD. The best and most certain
way of ensuring maximum porosity on the site is to locate the asset as far into the
northeast corner of the property as practicable. Doing so inherently leaves the
most possible room for separation from any new structures, thereby maximizing
potential porosity around the west and south sides of the asset. The presence of
the property lines, minimum setback requirements, and contiguous public
rights-of-way serve to ensure that no new development occurs on the north or
east sides of the resource.
In addition, the Applicant will restore the traditional streetscape along South
First Street by removing the inappropriate head-in parking for replacement with
a parkway strip that will include street trees, a detached sidewalk, and simple
but beautifying and low-height landscaping between the sidewalk and the
historic resource. With the proposed relocation, the Applicant will provide an
above-grade separation distance of not less than 10-feet between the historic
asset and any detached structures to be developed on the site.
C. Provide additional information for Guideline 9.2:
Proposals to relocate a building will be considered on a case-by-case basis.
1. In general, on-site relocation has less of an impact on individual landmark
structures than those in a historic district.
2. In a district, where numerous adjacent historic structures may exist, the way that
buildings were placed on the site historically, and the open yards visible from the
street are characteristics that should be respected in new development.
3. Provide a figure ground study of the surrounding parcels to demonstrate the
effects of a building relocation.
4. In some cases, the historic significance of the structure, the context of the site, the
construction technique, and the architectural style may make on-site relocation too
impactful to be appropriate. It must be demonstrated that on-site relocation is the
best preservation alternative in order for approval to be granted.
5. If relocation would result in the need to reconstruct a substantial area of the
original exterior surface of the building above grade, it is not an appropriate
preservation option.
D. Applicant Response to Guideline 9.2:
It is important to remember when reading this Guideline that the Code provides
that denial of the proposed relocation is not an option. The only question is
whether the proposed location on the site is appropriate for the asset, or whether
the relocation should be to a different place on the site. At the subject property,
the proposed relocation is consistent with both the zoning (i.e., no variations
33
205 W. Main Street – On-Site Relocation Page 4
needed) and the way buildings were placed historically. Because the house was
not built on this property but was moved here from a different site, its
positioning on the subject lot is not historically significant and can be adjusted
without impact to integrity of the asset.
The proposed location at the intersection of the front and east side yard setback
lines ensures maximization of open yards visible from the street once the
planned buildout of affordable housing on the site is factored in. Placing the
historic resource prominently at the corner to anchor the block will serve to
enhance the historic character of the block and its place within the District.
While this individual historic structure resides within the MSHD, it is original to
neither the site nor the District. In fact, the entire lot was vacant in 1904, and the
only original historic house remaining on this block face is 211 West Main Street,
which resides next door to the west. Said house remains the only structure
immediately adjacent to the subject corner lot and is currently undergoing a
renovation and addition to the side and rear portions of the house. Despite the
renovations, the historic portion of the 211 West Main house is quite obscured by
trees in the front yard. The existing landscaping of the 211 West Main Street
property diminishes any historic context or relationship formed by the between
the structures on the two properties. Nonetheless, the recently completed
setbacks context study clearly demonstrates that the proposed relocation
provides a setback that is highly consistent with that of the adjacent historic
resource. The two building faces, exclusive of front porches, would have a
distance from the curbline that is only 4-inches different, with the adjacent
resource being 29’-10” from the curbline and the proposed relocation setting the
subject asset’s building face at 29’-6” from the curbline. It is likely for these
reasons that staff found in their April 26, 2023 memo to the HPC that "the
proposed re-positioning of 205 W. Main does not diminish any historic relationship
between adjacent properties.”
Similarly, staff found that “the proposed on-site relocation is an appropriate
preservation outcome because it will provide [maximum] separation between the historic
resource and any future new construction, and will improve the visibility of the historic
structure.” The Applicants fully concur with this staff finding and the finding
cited in the previous paragraph, both of which demonstrate consistency with
Guideline 9.2 and the codified standards for review of an on-site relocation.
Additionally, as the context study shows, the proposed relocation is within 2- or
3-feet of the average front yard setback for all existing structures along the south
side of Main Street’s 100-400 blocks. That average setback line would run more
or less through the center of the relocated asset’s front porch. In short, the
proposed relocation plan is absolutely consistent with the surrounding
neighborhood and Main Street Historic District context, and through that lens, a
far more appropriate building placement than the location to which this asset
was originally relocated.
34
205 W. Main Street – On-Site Relocation Page 5
E. Provide additional information for Guideline 1.8:
Consider stormwater quality needs early in the design process.
1. When included in the initial planning for a project, stormwater quality facilities
can be better integrated into the proposal. All landscape plans presented for HPC
review must include at least a preliminary representation of the stormwater design.
A more detailed design must be reviewed and approved by Planning and Engineering
prior to building permit submittal.
2. Site designs and stormwater management should provide positive drainage away
from the historic landmark, preserve the use of natural drainage and treatment
systems of the site, reduce the generation of additional stormwater runoff, and
increase infiltration into the ground. Stormwater facilities and conveyances located
in front of a landmark should have minimal visual impact when viewed from the
public right of way.
3. Refer to City Engineering for additional guidance and requirements.
F. Applicant Response to Guideline 1.8:
The proposed relocation leaves more than ample lot area available for the
accommodation of stormwater quality needs. In fact, the current proposal will
decrease the amount of impermeable surface on the property through the
removal of the non-historic additions and outbuildings. Any further stormwater
design planning would be premature at this time.
Instead, when the subsequent administrative review application for the
development of additional affordable housing on the lot is prepared, preliminary
stormwater quality needs and management improvements will be included in
the design submissions. The Applicant understands the goals of ensuring that
stormwater management practices appropriately ensure protection of the historic
resource while meeting City engineering requirements. Preemptive and
thorough feasibility reviews have been conducted by the Applicant’s Civil
Engineer in coordination with the Engineering Department to verify the ability to
meet the guidelines. During that administrative review process, the Applicant
will work with staff and the HPC monitor/chair to ensure proper execution of
the stormwater management designs in accordance with Guideline 1.8.2.
G. Responses to Conditions of Approval
1. The width of the front walkway and the wood step leading to the Victorian
shall be narrowed to approximately three (3) feet. HPC is to determine
whether the walkway is to be gray concrete, brick or rectilinear flagstone, and
a sample of paving materials is to be reviewed and approved by staff and
monitor.
Response: The walkway and step have been revised and are now shown and
labeled as permeable pavers of approximately 3-feet in width. The Applicant is
35
205 W. Main Street – On-Site Relocation Page 6
amenable to HPC determining the walkway material and color with samples
being provided to staff and monitor for approval prior to installation.
2. Landscaping is to be simplified to avoid obstructing or damaging the resource.
A revised plan shall be reviewed and approved by staff and monitor.
Response: The proposed landscape plan has been simplified and clarified to
address the concerns of the previous staff memorandum and this recommended
condition. As such, this condition is no longer necessary. If necessary to
maintain the staff and monitor role in the eventual/final landscape design prior
to building permit issuance, the Applicant is okay with that.
3. The historic house foundation exposed to view above finished grade is to be
clad with metal flashing, with the detail to be approved by staff and monitor.
Response: This is shown and indicated/labeled on the “proposed” elevation
drawings, rendering this condition unnecessary.
4. The footprint of the proposed lightwell at southwest corner of the Victorian
shall be reduced or broken into two lightwells without negatively impacting
the abutting living spaces. Lightwells around the historic resource shall be
covered with grates, not railings. Lightwells and similar features abutting the
historic structures shall have a curb height of six (6) inches or less to minimize
visual and/or physical impacts to the historic resource.
Response: The proposed plans have been updated to pull the lightwell six inches
farther to the south, be decreased in size, and broken into two smaller lightwells.
The updated plans also include labels providing that lightwell curb heights will
be of less than or equal to 6” and that the lightwells shall include metal grate
coverings.
5. The non-historic west addition is approved to be removed from the historic
structure and the void infilled with clapboards.
Response: This is shown and indicated/labeled on the “proposed” elevation
drawings, rendering this condition unnecessary.
6. The pre-fabricated shed and trash enclosures are approved to be removed from
the site.
Response: Condition acknowledged.
7. The applicant has committed to retain and repair all exterior materials based
on field inspection with historic preservation staff, and at the same inspection
must work with historic preservation staff to identify and up to three
restoration actions that will be accomplished. An inspection of the interior of
the structure after finishes are removed will be required to ensure accurate
representation of the building’s history, and may also generate opportunities
for restoration (up to three total) that must be completed.
36
205 W. Main Street – On-Site Relocation Page 7
Response: We respectfully submit that this condition should be deleted. That is,
we feel it is inappropriate to require that we identify three MORE restoration
actions to be accomplished. Code Section 26.470.090.D.3.c. requires identification
of three (3) opportunities for restoration and commitment to complete such
restoration work. We have already commendably committed to more than the
codified requirement of "up to three" restoration actions, and we are not even
requesting any floor area bonuses or dimensional variations. For instance, the
proposal includes: (1) removal of the inappropriate roof overhang addition from
the southwest corner of the structure and restoring the affected areas; (2) removal
of the non-historic deck attached to the rear of the asset; (3) removal of the
inappropriate addition from the southwest side of the structure and restoring the
affected areas; (4) elimination of the non-historic exterior stairway/area well
from the side of the resource; (5) providing an improved, permanent foundation
that will stabilize the resource without noticeably altering its height above grade;
and (6) restoration of the streetscape of S. First Street. While the Applicant
continues to represent a commitment to retaining and repairing all exterior
materials based on field inspection with historic preservation staff, and to
cooperating in identifying and achieving additional restoration efforts that may
be identified during the construction process, the Applicant is not comfortable
putting a minimum number (i.e., 3, plus the 6 already proposed) of additional
restoration opportunities that must be identified and accomplished. It is instead
felt that the approval should recognize that the proposal already exceeds the
codified requirement that “up to three (3)” restoration efforts be completed
during construction.
8. Stormwater management cannot be fully detailed until after the additional
allowances on this site are verified, however the site plan represents no visible
stormwater features on the subject site surrounding the resource, which is a
condition of approval. A fully developed stormwater management plan shall
be provided in the application for Administrative Review.
Response: The language of this condition should be slightly revised to recognize
that the Administrative Review application will not include a “fully developed”
stormwater management plan. Instead, a complete and fully developed plan will
be provided with the building permit application, as appropriate. The
Administrative Review application will include a conceptual drainage study and
stormwater management plan, including identification and depiction of
proposed stormwater management facilities.
9. Any new fence between the historic resource and the street shall be no more
than forty-two inches (42”) in height and shall have no less than a solid to
void ratio of fifty-percent (50%).
Response: Condition acknowledged.
10. Once mechanical systems are designed, the architect must provide elevations
and a roof plan of the historic resource identifying the location of all vents,
37
205 W. Main Street – On-Site Relocation Page 8
flues, FDC and strobe, and mechanical equipment for review and approval by
staff and monitor. Avoid damage to historic materials and visually intrusive
locations.
Response: Condition acknowledged.
11. Provide cut sheets of all exterior light fixtures for review and approval by staff
and monitor.
Response: Condition acknowledged.
12. To relocate the house on the site, the Applicant shall provide a financial
security deposit of $30,000 at the time of permit issuance. The submission
shall include details on how the relocation will occur. Upon making a
determination that the home was successfully placed on the new foundation,
staff shall return the deposit to the Applicant.
Response: Condition acknowledged.
The attached plans also include floor area diagrams provided in response to public
comments made during the April 26, 2023, HPC meeting. The diagrams show
there is clearly no “addition” being made to the historic structure. Instead, the
structure will become smaller above-grade due to removal of the non-historic
additions.
It is hoped that the provided information and responses prove helpful in the
review of this application. If you should have any questions or desire any
additional information, please do not hesitate to contact me.
Truly yours,
Haas Land Planning, LLC
Mitch Haas
Owner/Manager
38
DRAWING ISSUE
DRAWN BY:
PROJECT No:2125
CPF
DUE DILIGENCE 2021-08-26
CONCEPTUAL 2021-10-21
HPC OPTION B 2022-11-07
HPC-RELOCATION 2023-05-31205 WEST MAIN | ASPEN CO 205 WEST MAIN All ideas, designs, arrangements and plans
indicated or represented by this drawing are
owned by and are the property of David Johnston
Architects, PC and developed for use and in
conjunction with the specified project. None
of the ideas, designs, arrangements or plans
shall be used by or disclosed for any purpose
whatsoever without the written authorization
of David Johnston Architects, PC.
119 South Spring St.
Suite 203
Aspen, CO 81611
970-925-3444
970-920-2186
TEL
FAX
A1.03
SITE PLAN | RELOCATION
PLAN | 1:10 AFFORDABLE HOUSING Sheet No.
N
PROPOSED HISTORIC
STRUCTURE FOOTPRINT15'-219/64"10'-0"5'-0"5'-0"5'-0"LIGHT WELL
SHIFTED SOUTH 6"
NON-HISTORIC SHEDS
TO BE REMOVED
METAL GRATE COVER
OVER LIGHT WELLS, TYP.
EXISTING NON-HISTORIC
DECK FOOTPRINT
EXISTING NON-HISTORIC
ROOF OVERHANG
LIGHT
WELL
LIGHT
WELL
PROPERTY LINESETBACKSETBACKPROPERTY LINE
PROPERTY LINE
SETBACK
LIGHT
WELL
LA-1
3'-0"
FOOTPRINT OF EXISTING
HISTORIC STRUCTURE
EXISTING EXTERIOR
BASEMENT ACCESS TO BE
REMOVED
EXISTING PARKING-
TO BE REMOVED
NEW SIDEWALK
ALONG FIRST STREET
SETBACK
PROPERTY LINESCALE: 1" = 10'1 SITE PLAN | PROPOSED HISTORIC RELOCATION | 1:10
0 5'10'20'
LA-1 = 3' WIDE WALKWAY AND STAIR WILL BE GREY CONCRETE, BRICK,
OR RECTILINEAR FLAGSTONE WITH SAMPLES TO BE APPROVED BY STAFF AND MONITOR PRIOR TO INSTALLATION
39
PRELIMINARYSCHEMATICPLANL0.10DATE:DRAWN BY:CHECKED BY:ISSUE:HISTORY:BAJSHEET TITLE:MAIN STREETVICTORIANFOR PLANNINGPURPOSES ONLYNOT FOR CONSTRUCTION05.31.2023ADDRESS:205 W. MAIN ST.ASPEN, CO 81611PARCEL #---------------PSRDATE04.20.202204.26.2023ISSUEHPCHPCSTAMP PER DISCIPLINEPITKIN COUNTY STAMPS0'3'6'12'SCALE: 1"= 6'-0"NORTHDRAFTIVORY SILK JAPANESE TREE LILACRHAPSODY BLUE HYDRANGEAROCKY MOUNTAIN COLUMBINEFIREFLY CORAL BELLSLILY -OF-THE-VALLEYORCHID FROST DEAD NETTLEBELGARD PERMEABLE PAVERFLAGSTONE STEPPERS &FLAGSTONE PATIO(2) IVORY SILK JAPANESE TREELILAC, TYP.(26) FIREFLY CORAL BELLS, TYP.(15) DEAD NETTLE, TYP.(9) RHAPSODY BLUE HYDRANGEA,TYP.(22) ROCKY MOUNTAIN COLUMBINE,TYP.(16) LILY-OF-THE-VALLEY,TYP.EXISTING TREES TO REAMINPROPOSED FLAGSTONESTEPPERS, TYP.PROPOSED PERMEABLEPAVERS, TYP.LAWNLAWNPROPERTY LINEPROPERTY LINESETBACKHISTORIC RESOURCEFLAGSTONE PATIO, TYP.BIKE PARKINGBENCH, TYP.ALLEYEXISTING SIDEWALKEXISTING SIDEWALKPROPOSED SIDEWALK(7) PROPOSED DECIDUOUS TREETYP.18" PROTECTION BANDEXISTING CONDITIONS40
DRAWING ISSUE
DRAWN BY:
PROJECT No:2125
CPF
DUE DILIGENCE 2021-08-26
CONCEPTUAL 2021-10-21
HPC OPTION B 2022-11-07
HPC-RELOCATION 2023-05-31205 WEST MAIN | ASPEN CO 205 WEST MAIN All ideas, designs, arrangements and plans
indicated or represented by this drawing are
owned by and are the property of David Johnston
Architects, PC and developed for use and in
conjunction with the specified project. None
of the ideas, designs, arrangements or plans
shall be used by or disclosed for any purpose
whatsoever without the written authorization
of David Johnston Architects, PC.
119 South Spring St.
Suite 203
Aspen, CO 81611
970-925-3444
970-920-2186
TEL
FAX
A1.07
FLOOR AREA AFFORDABLE HOUSING Sheet No.
DN #101-3 BED AH UNIT
267.03 sq ft
DNUP
DN
UP #102-2 BED AH UNIT
412.03 sq ft
#101-3 BED AH UNIT
468.41 sq ft DN
DN
DN
UP
#102-2 BED AH UNIT
414.49 sq ft
#101-3 BED AH UNIT
387.38 sq ft
EXISTING VS. PROPOSED NET LIVABLE
PLAN
EXISTING
PROPOSED
#101-1 BED APARTMENT
#102-3 BED APARTMENT
#102-3 BED APARTMENT
#101-3 BED AH UNIT
#101-3 BED AH UNIT
#101-3 BED AH UNIT
#102-2 BED AH UNIT
#102-2 BED AH UNIT
LEVEL
LOWER
MAIN LEVEL
SECOND LEVEL
LOWER
MAIN LEVEL
SECOND LEVEL
LOWER
MAIN LEVEL
AREA
802.62
939.24
343.13
2,084.99 ft²
468.41
387.38
267.03
412.03
414.49
1,949.34 ft²
4,034.33 ft²
#102-3 BED APARTMENT
939.24 sq ft #101-1 BED APARTMENT
802.62 sq ft
#102-3 BED APARTMENT
343.13 sq ft
N
SCALE: 3/16" = 1'-0"2 PROPOSED UPPER LEVEL PLAN
SCALE: 3/16" = 1'-0"-1.PROPOSED BASEMENT PLAN
SCALE: 3/16" = 1'-0"1 PROPOSED MAIN LEVEL PLAN
SCALE: 3/16" = 1'-0"1 EXISTING MAIN LEVEL PLAN
SCALE: 3/16" = 1'-0"-1 EXISTING BASEMENT PLAN
SCALE: 3/16" = 1'-0"2 EXISTING UPPER LEVEL PLAN
NON-HISTORIC ADDITION
(TO BE REMOVED)
EXISTING BASEMENT
ACCESS STAIR
EXISTING LIGHTWELLEXISTING LIGHTWELL
NON-HISTORIC DOOR
(TO BE REMOVED)
NON-HISTORIC CHIMNEY
(TO BE REMOVED)
EXISTING BASEMENT
ACCESS STAIR
EXISTING LIGHTWELL
PROPOSED LIGHTWELL
PROPOSED LIGHTWELL
PROPOSED LIGHTWELL
EXISTING LIGHTWELL
PROPOSED LIGHTWELL
PROPOSED LIGHTWELL
PROPOSED LIGHTWELL
41
DRAWING ISSUE
DRAWN BY:
PROJECT No:2125
CPF
DUE DILIGENCE 2021-08-26
CONCEPTUAL 2021-10-21
HPC OPTION B 2022-11-07
HPC-RELOCATION 2023-05-31205 WEST MAIN | ASPEN CO 205 WEST MAIN All ideas, designs, arrangements and plans
indicated or represented by this drawing are
owned by and are the property of David Johnston
Architects, PC and developed for use and in
conjunction with the specified project. None
of the ideas, designs, arrangements or plans
shall be used by or disclosed for any purpose
whatsoever without the written authorization
of David Johnston Architects, PC.
119 South Spring St.
Suite 203
Aspen, CO 81611
970-925-3444
970-920-2186
TEL
FAX
A3.01
ELEVATIONS AFFORDABLE HOUSING Sheet No.
100'-0"
MAIN LEVEL
108'-10"
SECOND LEVEL
ASPHALT SHINGLE
6" LAP SDING
SCALLOPED SHINGLE
SCALLOPED SHINGLE
100'-0"
MAIN LEVEL
108'-10"
SECOND LEVEL
ASPHALT SHINGLE
6" LAP SDING
6" LAP SIDING
WITH COLOR
GRADIENT
SCALLOPED SHINGLE
100'-0"
MAIN LEVEL
108'-10"
SECOND LEVEL
ASPHALT SHINGLE
ASPHALT SHINGLE
6" LAP SDING
HD HC HB HAH1H2H3H4H5H6
H6 H5 H4 H3 H2 H1
SCALE: 1/4" = 1'-0"1 NORTH ELEVATION
0 2'4'8'
SCALE: 1/4" = 1'-0"2 EAST ELEVATION
0 2'4'8'SCALE: 1/4" = 1'-0"3 SOUTH ELEVATION
0 2'4'8'
42
DRAWING ISSUE
DRAWN BY:
PROJECT No:2125
CPF
DUE DILIGENCE 2021-08-26
CONCEPTUAL 2021-10-21
HPC OPTION B 2022-11-07
HPC-RELOCATION 2023-05-31205 WEST MAIN | ASPEN CO 205 WEST MAIN All ideas, designs, arrangements and plans
indicated or represented by this drawing are
owned by and are the property of David Johnston
Architects, PC and developed for use and in
conjunction with the specified project. None
of the ideas, designs, arrangements or plans
shall be used by or disclosed for any purpose
whatsoever without the written authorization
of David Johnston Architects, PC.
119 South Spring St.
Suite 203
Aspen, CO 81611
970-925-3444
970-920-2186
TEL
FAX
A3.02
ELEVATIONS AFFORDABLE HOUSING Sheet No.
89'-6"
LOWER
89'-6"
LOWER
100'-0"
MAIN LEVEL
100'-0"
MAIN LEVEL
108'-10"
SECOND LEVEL
108'-10"
SECOND LEVEL
5"PROPOSED
RESTORATION OF
SHED ROOF
RAKE CONDITION
AREA OF RESTORATION
NON-HISTORIC ADDITION
REMOVED AND RESTORED
WITH MATCHING FINISHES
METAL CLADDING ON ABOVE
GRADE FOUNDATION WALL
TYPICAL (SEE DETAIL A)
LIGHT WELL MOVED 6" SOUTH
LIGHT WELLS-6" MAX UBAOVE
GRADE WITH METAL GRATE
COVER TYPICAL
HA HB HC HD
DRAWING ISSUE205 WEST MAIN AFFORDABLE HOUSING205 WEST MAIN ST. | ASPEN, COSHEET No.
CONCEPTUAL
DESIGN REVIEW
DESIGN REVIEW
DESIGN DEV.
DRAWN BY:
PROJECT No:2007
#CAD Technician Full Name
119 South Spring St.
Suite 203
Aspen, CO 81611
970-925-3444
970-920-2186
TEL
FAX
7.1
DETAIL
6/05/08
7/01/08
7/31/08
4/25/2023
All ideas, designs, arrangements and plans indicated or represented by this drawing are owned by and are the property of David Johnston Architects, PC and developed for use and in conjunction with the specified project. None of the ideas, designs, arrangements or plans shall be used by or disclosed for any purpose whatsoever without the written authorization of David Johnston Architects, PC.SHEET No.
2"43/4"11/4"3/4"
SHEET METAL SKIRT
WATER TABLE-
SKIRT BOARD
WATER TABLE-
CAP BOARD
GRADE ELEVATION VARIES
CLAPBOARD SIDING
SCALE: 1 1/2"= 1'-0"A WATER TABLE & METAL SKIRT DETAIL
0 6''12''18''
SCALE: 1/4" = 1'-0"4 WEST ELEVATION
0 2'4'8'
43
CURRENT FOOTPRINT
PROPERTY LINE
Main Street Setback Study
PROPOSED FOOTPRINT
205 WEST MAIN
SOUTH 2ND ST SOUTH 1ST ST WEST HOPKINS AVE
WEST MAIN STREET
19” - 5”
21’ - 1”
22’ - 9”14” - 0”22’ - 9”
29’ - 10”35’ - 9”29’ - 6”32’ - 8”
23’ - 2”
23’ - 8”
23’ - 5”
17’ - 8”
25’ - 6”
34’ - 11”23’ - 10”28’ - 4”33’ - 4”200 BLOCK SOUTH 100 BLOCK SOUTH
10050250
Scale In Feet
CURRENT SETBACK
CURRENT SETBACK
BUILDING ENVELOPE
FRONT OF PORCH
BUILDING ENVELOPECurrent Distance From Curb
Proposed Distance From Curb
Proposed Setback Line
Overhang
Parking
Historic Structure
44
34’ - 6”37’ - 2”35’ - 9”42’ - 6”42’ - 4”42’ - 3”31’ - 9037’ - 3”CURRENT FOOTPRINT
PROPERTY LINE
Main Street Setback Study
CURRENT SETBACK
CURRENT SETBACK PROPOSED SETBACK
PROPOSED SETBACK
WEST MAIN STREET
SOUTH 2ND ST SOUTH 1ST ST WEST HOPKINS AVE WEST HOPKINS AVE
WEST MAIN STREET
SOUTH 3RD STNORTH 2ND ST NORTH 1ST ST NORTH 3RD ST200 BLOCK NORTH 300 BLOCK NORTH 100 BLOCK NORTH
200 BLOCK SOUTH300 BLOCK SOUTH 100 BLOCK SOUTH
19” - 5”
21’ - 1”
22’ - 9”14” - 0”22’ - 9”
29’ - 10”35’ - 9”32’ - 8”
23’ - 2”
23’ - 8”
23’ - 5”
17’ - 8”
25’ - 6”
34’ - 11”29’ - 8”23’ - 10”28’ - 4”33’ - 4”20’ - 1”20’ - 2”25’ - 6”34’ - 5”24’ - 1”
21’ - 1”
23’ - 2”
22’ - 11”
21’ - 9”
23’ - 0”24’ - 6”23’ - 5”12’ - 5”17’ - 1”16’ - 6”25’ - 6”
44’ - 7”
74’ - 10”
24’ - 10”
44’ - 0”
20’ - 1”22’ - 11”23’ - 8”
10050250
Scale In Feet
200
Current Distance From Curb
Proposed Distance From Curb
Proposed Setback Line
Overhang
Parking
Historic Structure
45
Main Street Setback Study
HISTORIC DISTRICT BLOCKS 100-700
CURRENT FOOTPRINT
PROPERTY LINE
PROPOSED FOOTPRINT
WEST MAIN STREET
SOUTH 1ST ST WEST MAIN STREET NORTH 1ST ST SOUTH 2ND ST NORTH 2ND ST SOUTH 3RD ST NORTH 3RD ST SOUTH 4TH ST NORTH 4TH ST SOUTH 5TH ST NORTH 5TH ST SOUTH 6TH ST SOUTH 7TH ST NORTH 6TH ST NORTH 7TH ST WEST MAIN STREET
100 BLOCK SOUTH 200 BLOCK SOUTH 300 BLOCK SOUTH 400 BLOCK SOUTH 500 BLOCK SOUTH 600 BLOCK SOUTH 700 BLOCK SOUTH
700 BLOCK NORTH 100 BLOCK NORTH 200 BLOCK NORTH 300 BLOCK NORTH400 BLOCK NORTH 500 BLOCK NORTH 600 BLOCK NORTH
Building Setback From Curb
Proposed Alignment
Average Setback (100-400 Block South)
Average Setback Distance From Curb
24’ - 9”
10050 250 5000
Scale In Feet
46
Land Use Application
City of Aspen Historic Preservation Commission
16 March 2023
Location: 205 W. Main Street, Aspen, CO (PID# 273512454003)
An application for Relocation of an Historic Resource.
Planning Representation: Architect:
47
205 W. Main Street / HPC Minor Development
(PID# 273512454003)
16 March 2023 P a g e | 1
TABLE OF CONTENTS
Project Overview
Attachment 1 - Land Use Code Response
Attachment 2 - Vicinity Map and Property Description
Attachment 3 - Site Improvement Survey
Attachment 4 - Relocation and Schematic Landscape Plans
Attachment 5 - Historic Structure Relocation Assessment
Attachment 6 - Signed Fee Agreement
Attachment 7 - Letter Authorizing Representation
Attachment 8 - HOA Compliance Form
Attachment 9 - Proof of Ownership
Attachment 10 - List of Adjacent Property Owners
Attachment 11 - Pre-Application Conference Summary, dated 23 February 2022
48
205 W. Main Street / HPC Minor Development
(PID# 273512454003)
16 March 2023 P a g e | 2
PROJECT OVERVIEW
This application is submitted on behalf of Conservation Housing Partners LLC (the “Applicant”) for
the property located at 205 W Main Street, Aspen, Colorado, PID# 273512454003 (the “Property”).
The Property is a 7,500 square foot lot which contains a Victorian era single family home or miner’s
cottage with accessory dwelling unit. The home was constructed in 1890 and moved to its current
location in 1949 from a location just outside the Aspen Townsite. The Property is zoned Mixed-Use
(MU) and has landmark designation.
The building consists of 2,226 SF of residential floor area a nd incorporates two existing residential
units, one free-market unit and one deed-restricted accessory dwelling unit. The eventual
development of the property would include a 100% affordable residential development. Plans for
that development are not fully available at this time.
The intent of this application is to relocate a historic residence that is currently more or less
centered on its 7,500 square foot lot. The residence would be moved to a 3,000 square foot portion
of the property. This location would feature the historic residence more prominently and provide
a location that is more consistent with historic miner’s cottages of this size.
The scope of work would include the demolition of a small non-historic addition at the southwest
corner of the miner’s cottage and re-positioning it on a new foundation at the northeast corner
of the Property. A small non-historic shed on the Property would be removed as well. Basement
window wells would be expanded to provide additional livability to the subgrade area. No
window wells would be located in setbacks. Landscaping will be provided to screen these window
wells from the street.
Code requirements, such as setback and height are all met by the proposed relocation. A small
amount of additional floor area is added to the structure through the expansion of window wells.
On the other hand, a small amount of floor area is removed through the removal of the non -
historic addition. The result is a zero net gain in floor area. The window wells for the subgrade area
do not increase the bulk and massing of the proposed relocation.
Given the proximity to the commercial core and it location within the Main Street Historic District,
we believe that this relocation is uniquely situated to showcase the historic residence. The
restoration and preservation of the historic miner’s cottage at a prominent corner location
preserves an important example of Aspen’s historic built environment. The site will be well-
landscaped in accordance with Historic Preservation Guidelines, with a protective surround for
the historic resource.
Since the property currently consists of two and one-half Townsite lots, moving the historic
residence to the area of an original single original Townsite lot is in keeping with the historic siting
of these cottages. Streetscape improvements along First Street will include the elimination of an
informal parking area currently in the City right-of-way and appropriate street tree plantings.
49
205 W. Main Street / HPC Minor Development
(PID# 273512454003)
16 March 2023 P a g e | 3
LAND USE CODE RESPONSE
Sec. 26.415.070(c). - Development involving designated historic property or property within
a historic district.
(d) Certificate of appropriateness for m inor development.
(1) The review and decision on the issuance of a certificate of appropriateness for major
development shall begin with a determination by the Community Development Director that the
proposed project constitutes a m inor development. A m inor development includes one or more
of the following activities:
a. Expansion or erection of a structure wherein the increase of the floor area of the structure is
two hundred and fifty (250) square feet or less or
b. Alterations to a building façade, windows, doors, roof planes or material, exterior wall
materials, dormer porch, exterior staircase, balcony or ornamental trim when three (3) or
fewer elements are affected and the work does not qualify for a certificate of no negative effect
or
c. Erection or installation of a combination or multiples of awning, canopies, mechani cal
equipment, fencing, signs, accessory features and other attachments to designated properties
such that the cumulative impact does not allow for the issuance of a certificate of no negative
effect;
d. Alterations that are made to nonhistoric portions of a designated historic property that do not
qualify for a certificate of no negative effect; or
e. The erection of street furniture, signs, public art and other visible improvements within
designated historic districts of a magnitude or in numbers such that the cumulative impact
does not allow for the issuance of a certificate of no negative effect.
This project meets the criteria for a minor development.
a. No net increase in floor area will result from the relocation. A slight increase in
subgrade floor area resulting from expanded window wells will be offset by the
removal of non-historic elements.
b. No alterations are proposed for the building façades or any other building elements
as described in this subsection.
c. No additional elements such as awnings, canopies, etc. are proposed.
d. Removal of a non-historic addition to the resource will qualify for a certificate of no
negative effect.
e. No street furniture, signs, public art or other visible improvements are proposed.
(2) An application for minor development shall include the following:
a. The general application information required in Section 26.304.030.
b. Scaled elevations and/or drawings of the proposed work and its relationship to the designated
historic buildings, structures, sites and features within its vicinity.
c. An accurate representation of all building materials and finishes to be used in the
development.
d. Photographs and other exhibits, as needed, to accurately depict location, extent and design of
proposed work.
e. Verification that the proposal complies with Chapter 26.410, Residential design standards or
a written request for a variance from any standard that is not being met.
This application provides a relocation plan and other materials as specified in the Pre -
Application Conference Summary dated 23 February 2023 . No changes to existing
50
205 W. Main Street / HPC Minor Development
(PID# 273512454003)
16 March 2023 P a g e | 4
building materials or finishes are proposed. All residential design standards are met
through this proposed relocation.
(3) The procedures for the review of minor development projects are as follows:
a. The Community Development Director will review the application materials and if they are
determined to be complete, schedule a public hearing before the HPC. The subject property
shall be posted pursuant to Paragraph 26.304.060(e)(3)b.
b. Staff shall review the submittal material and prepare a report that analyzes the project's
conformance with the design guidelines and other applicable Land Use Code sections. This
report will be transmitted to the HPC with relevant information on the proposed project and
a recommendation to approve, disapprove or approve with conditions and the reasons for the
recommendation. The HPC will review the application, the report and the evidence presented
at the hearing to determine the project's conformance with the City Historic Pres ervation
Design Guidelines.
c. The HPC shall approve, disapprove, approve with conditions or continue the application to
obtain additional information necessary to make a decision to approve or deny. If the
application is approved, the HPC shall issue a certificate of appropriateness and the
Community Development Director shall issue a development order.
d. The HPC decision shall be final unless appealed by the applicant or a landowner within three
hundred (300) feet of the subject property in accordance with the procedures set forth in
Chapter 26.316.
The procedures for Relocation Review are understood. It is understood that review will
be performed by the Historic Preservation Commission .
Chapter 26.415.090 Relocation of designated historic properties
The intent of this Chapter is to preserve designated historic properties in their original locations as muc h of
their significance is embodied in their setting and physical relationship to their surroundings as well as their
association with events and people with ties to particular site. However, it is recognized that occasionally the
relocation of a property may be appropriate as it provides an alternative to demolition or because it only has
a limited impact on the attributes that make it significant.
(a) Application. An application for relocation shall include:
(1) The general application information required in Section 26.304.030 .
(2) A written description and/or graphic illustrations of the building, structure or object proposed
for relocation.
(3) A written explanation of the type of relocation requested (temporary, on -site or off-site) and
justification for the need for relocation.
(4) A written report from a licensed engineer or architect regarding the soundness of the building,
structure or object, its ability to withstand the physical move and its rehabilitation needs, once
relocated.
(5) A conceptual plan for the receiving site providing preliminary information on the property
boundaries, existing improvements and site characteristics and the associated planned
improvements.
(6) If the applicant does not own the receiving site, proof from the site's property owner of the
willingness to accept the relocated building, structure or object.
(7) Evidence that the applicant has or is seeking the necessary approvals to place the building on
the identified receiving site. If the site is outside of the city limits, verification that the building
will be preserved on its new site through a formal action of the other jurisdiction or a
preservation easement.
(8) Evidence of the financial ability to undertake the safe relocation, preservation and repair of the
building, structure or object; site preparation and construction of necessary infrastructure
through the posting of bonds or other financial measures deemed appropriate.
51
205 W. Main Street / HPC Minor Development
(PID# 273512454003)
16 March 2023 P a g e | 5
(9) Supplementary materials to provide an understanding of the larger context for the relocated
property and its impact on adjacent properties, the neighborhood or streetscape.
Graphic illustrations of the building are provided with this application. The relocation will
be on-site and provide for possible future development of the Property as affordable
housing. Relocation will provide a perman ent and improved foundation that will stabilize
the historic resource. The architects attest to the soundness of the building and its ability
to withstand a physical move and rehabilitation. The plan for the relocation is provided
as part of this application. The receiving site is owned by the applicant and is within the
jurisdiction of the City of Aspen. The applicant has the financial ability to undertake the
safe relocation of the historic resource as well as carrying forward the other aspects of
this application. Bonding or other financial instruments may be provide d as stipulated in
final approval for the project.
The proposed development is in conformance with all zoning parameters for the Mixed-
Use zone district and is consistent with other development along Main Street.
(b) Procedures for the review of relocation request.
(1) The Community Development Director shall review the application materials submitted for
relocation approval. If they are determined to be complete, the applicant will be notified in
writing of this and a public hearing before the HPC shall be scheduled.
(2) Notice for the review of the relocation request shall include publication, posting and mailing
pursuant to Section 26.304.060(e)(3) Paragraphs a, b and c.
(3) If the relocation request is part of a major development project, the Community Development
Director may consolidate or modify the review process accordingly pursuant to Section
26.304.060 (b).
(4) Staff shall review the submittal material and prepare a r eport that analyzes the project's
conformance with the standards for relocation approval set forth below, the City Historic
Preservation Design Guidelines and other applicable Land Use Code sections. This report will
be transmitted to the HPC with relevant information on the proposed project and a
recommendation to continue, approve, disapprove or approve with conditions and the reasons
for the recommendation. The HPC will review the application, the report and the evidence
presented at the hearing to deter mine if the standards for relocation have been met.
(5) The HPC shall approve, disapprove, approve with conditions or continue the application to
obtain additional information necessary to make a decision to approve or deny.
(6) A resolution of the HPC action will be forwarded to the City Council in accordance with Section
26.415.120 and no relocation will occur until after the thirty (30) day "call up" period of the
City Council has expired.
These procedures are understood and appropriate public notice will be provided by the
Applicant.
(c) Standards for the relocation of designated properties. Relocation for a building, structure or object
will be approved if it is determined that it meets any one of the following standards:
(1) It is considered a noncontributing element of a historic district and its relocation will not affect
the character of the historic district; or
(2) It does not contribute to the overall character of the historic district or parcel on which it is
located and its relocation will not have an adverse impact on the Historic District or property;
or
(3) The owner has obtained a certificate of economic hardship; or
52
205 W. Main Street / HPC Minor Development
(PID# 273512454003)
16 March 2023 P a g e | 6
(4) The relocation activity is demonstrated to be an acceptable preservation method given the
character and integrity of the building, structure or object and its move will not adversely affect
the integrity of the His toric District in which it was originally located or diminish the historic,
architectural or aesthetic relationships of adjacent designated properties; and
The relocation activity represents an acceptable preservation method given the
character and integr ity of the building. Its relocation will bring an historic resource into
closer focus as a contributing element to the Main Street Historic District. The relocated
property is a contributing element to the Main Street Historic District, but its relocation will
not affect or detract from the character of the historic district. This standard has been
met.
Additionally, for approval to relocate all of the following criteria must be met:
(1) It has been determined that the building, structure or object is capable of withstanding the
physical impacts of relocation;
(2) An appropriate receiving site has been identified; and
(3) An acceptable plan has been submitted providing for the safe relocation, r epair and preservation
of the building, structure or object including the provision of the necessary financial security.
The architects have determined that the frame structure is capable of withstanding the
physical impacts of relocation. The actual reloc ation site is very close to the structure’s
existing location. An appropriate plan is provided for the safe relocation, repair, and
preservation of the building. Financial security will be provided as required.
(d) Procedures for considering request for relocation of properties under consideration for
designation. While it is the intent of this Chapter to preserve properties of demonstrated
significance, it is also recognized that all buildings and areas of importance to the general welfare,
prosperity and civic pride of its citizenry cannot be identified, evaluated, documented and
designated at one time. However, it is important to protect properties which potentially qualify for
designation against needless loss until review and hearings can be completed .
(1) No relocation will be permitted for properties under consideration for designation to the Aspen
Inventory of Historic Landmark Site and Structures unless relocation approval is issued by the
Historic Preservation Commission or City Council.
(2) All properties under consideration for designation and, therefore, subject to the temporary stay
of relocation will be identified on a list maintained by the Chief Building Official. Property
owners will be notified by registered mail that their property is under con sideration for
designation and have an opportunity to review all materials compiled at that time to verify
accuracy.
(3) These procedures shall apply to any building located within an area under preliminary
application for designation from the time the applic ation is filed until the time action is taken
on the application by the City Council.
(4) If a public hearing to consider the application for designation is not held by the City Council
within six (6) months of the initiation of the stay, the stay will expire . An additional six -month
stay period may be approved by City Council in the form of a resolution, at a public hearing,
with a showing of good cause.
The proposed relocation of a designated historic resource constitutes a minor
application for review by th e Historic Preservation Commission .
53
205 W. Main Street / HPC Minor Development
(PID# 273512454003)
16 March 2023 P a g e | 7
Sec. 26.710.180. Mixed Use (MU) Zone District
(a) Purpose. The Mixed Use (MU) zone serves as a transition from the more intense commercial areas
of the CC and C-1 zones, and the residential and lodging zones surrounding Main Street. By allowing
for a mix of commercial and residential uses and smaller -scale development, the Mixed Use zone
reflects Aspen's historic character and provides different economic and residential opportunities
from more traditional comm ercial zones. Particularly along Main Street, the Mixed Use zone serves
as a buffer from the traffic of Highway 82 while allowing for smaller scale commercial and
residential opportunities.
Buildings in the Mixed Use zone consist primarily of commercial, service and office uses on the ground floor,
and residential and office uses on upper floors and off of the primary street frontage. Uses in the MU zone
should not erode the character of the neighborhood or create excessive impacts to the surro unding residential
and lodging zone. Standalone residential uses are permitted on properties as a reflection of the historic
residential nature of the zone district.
(b) Permitted uses. The following uses are permitted as of right in the Mixed -Use (MU) Zone District:
(1) On historic landmark properties: Bed and breakfast.
(2) General retail uses.
(3) Specialty retail uses.
(4) Restaurant, bar and entertainment uses.
(5) Service uses.
(6) Office uses.
(7) Lodging.
(8) Arts, cultural, civic and community uses.
(9) Public uses.
(10) Recreational uses.
(11) (Academic uses.
(12) Affordable multi-family residential.
(13) Free-market multi-family housing is permitted in a mixed use building if the housing was legally
established (having received a Certificate of Occupancy, Development Order, or applied for a
Development Order) prior to Ordinance 29, Series 2016. No new Free -Market Residential Units
may be established in mixed -use buildings.
(14) Free-market multi-family residential when a stand-alone use, or in conjunction with affordable
multi-family residential.
(15) Single-family residence, Duplex residence, or two (2) detached single -family residences.
Accessory dwelling unit in a separate building accessed off the rear of a lot as an accessory use.
(16) Home occupations.
(17) Accessory uses and structures.
(18) Storage accessory to a permitted use.
(19) Vacation rentals. Pursuant to Section 26.575.220.
The proposed relocation will not affect the current residential use of the building .
Standalone residential uses are permitted as a reflection of the historic residential nature
of the zone district.
(c) Conditional uses. The following uses are permitted as conditional uses in the Mixed -Use (MU) Zone
District, subject to the standards and procedures established in Chapter 26.425:
(1) Commercial parking facility, pursuant to Chapter 26.515.
(2) Automobile showroom and dealership.
(3) Formula uses in the Main Street Historic District, subject to the provisions contained in Section
26.425.045 .
(4) Lodge, Boutique.
Condition use approval is not required for this application.
54
205 W. Main Street / HPC Minor Development
(PID# 273512454003)
16 March 2023 P a g e | 8
(d) Dimensional requirements. The following dimensional requirements shall apply to all permitted and
conditional uses in the Mixed -Use (MU) Zone District. The dimensional standards and allotments
provided in this Section for commercial and mixed -use developments are the maximum allowable
for the zone and may not be achieved for all developments. Site constraints, historic resources, on -
site mitigation and replacement requir ements, and other factors may prevent development from
achieving some or all of the maximum allowable dimensional standards.
(1) Minimum Gross Lot Area (square feet): Three thousand (3,000).
The Property consists of a gross lot area of 7,500 SF, so this requi rement is met. The
relocation area would consist of a n area equivalent to an original platted Townsite lot of
3,000 SF.
(2) Minimum Net Lot Area per dwelling unit (square feet):
a. Detached residential dwellings : Four thousand five hundred (4,500). Three thousand (3,000)
for historic landmark properties.
b. Duplex dwellings (square feet): Four thousand five hundred (4,500). Three thousand (3,000)
for historic landmark properties.
c. All other uses: Not applicable.
The minimum lot area requirement of 3,000 SF fo r a historic landmark is met.
(3) Minimum lot width (feet): Thirty (30).
This requirement is met. The lot width is seventy -five (75) feet.
(4) Minimum front yard setback (feet): Ten (10), which may be reduced to 5, pursuant to Special
Review, Chapter 26.430.
(5) Minimum side yard setback (feet): Five (5).
(6) Minimum rear yard setback (feet): Five (5).
These requirements are met. No reduction s are requested.
(7) Minimum utility/trash/recycle area: Pursuant to Chapter 12.06.
A trash/recycling area will be provided meeting all requirements of the Code.
(8) Maximum height:
a. Detached residential and duplex dwellings : Twenty-five (25) feet.
b. All other uses: Twenty-eight (28) feet.
No new construction is proposed that would increase the existing height of the
residence, which meets the 28-foot height limit requirement.
(9) Minimum distance between buildings on the lot (feet): Ten (10).
Not applicable, as there are no other buildings on the site. Any future new construction
would observe this requirement.
(10) Pedestrian amenity space: Pursuant to Section 26.412 .
Not applicable. Pedestrian amenity space is not required for a 100% residential project.
(11) Floor Area Ratio (FAR):
55
205 W. Main Street / HPC Minor Development
(PID# 273512454003)
16 March 2023 P a g e | 9
a. The following FAR schedule applies to uses cumulatively and individually when part of a
commercial, lodging, or mixed-use development, as follows:
Use Maximum
(allowed by right)
Maximum by special review
(see Subsection 26.430.040(a))
Main Street
Historic District
All Other
Locations
Cumulative total of all uses 1:1 1.25:1 1.5:1
Commercial 1:1 1.25:1 1.5:1
Civic 1:1 1.25:1 1.5:1
Lodging 0.75:1 1:1 1:1
Affordable Housing No limitation other than cumulative total of all uses
b. The following FAR schedule applies to affordable housing and free-market residential uses
when developed as the only use of the parcel:
1. Affordable Housing, multi -family housing: Limited to cumulative total outlined
in Section 26.710.180 (d)(11)a, above.
2. Free-market, affordable housing : 0.5:1, which may be increased to 0.75:1 if affordable
housing floor area equal to one hundred p ercent (100%) of the free-market residential
floor area is developed on the same parcel.
For an affordable housing project, t his 7,500 SF property would carry a maximum floor
area ratio of 1:1 or 7,500 SF by right. With Special Review, as provided in the Land Use
Code, the floor area ratio may be increased to 1.25:1. This would provide an allowable
floor area of 9,587.5 SF.
However, the proposed floor area in this application is unchanged and no request for
additional floor area is included here.
c. The following FAR schedule applies to single -family and duplex uses when developed as the
only use of the parcel:
1. Detached residential and duplex dwellings established prior to the adoption of
Ordinance No. 7, Series of 2005 : One hundred percent (100%) of the allowable floor
area of an equivalent-sized lot located in the R-6 Zone District. (See R -6 Zone District.)
Receipt of a development order shall constitute the date the use was established.
Replacement after demolition shall not effect a new e stablishment date for the purposes
of this Section. City historic transferable development rights shall not permit additional
floor area for detached residential and duplex dwellings.
2. Detached residential and duplex dwellings established after the adoption of Ordinance
No. 7, Series of 2005: Eighty percent (80%) of the allowable floor area of an equivalent -
sized lot located in the R-6 Zone District. (See R-6 Zone District.) City historic
transferable development rights shall not permit additional floor area for detached
residential and duplex dwellings.
56
205 W. Main Street / HPC Minor Development
(PID# 273512454003)
16 March 2023 P a g e | 10
Not applicable to this application.
(12) Maximum multi-family residential dwelling unit size (square feet):
a. Category 1-7 Affordable multi-family housing: No limitation.
b. Resident Occupied Affordable multi-family housing: Individual units shall be limited to two
thousand (2,000) square feet of net livable area.
c. Free-Market multi-family housing: Individual units shall be limited to two thousand (2,000)
square feet of net livable area. Combination of Fre e-Market residential units is permitted,
but subject to the net livable size limitations herein, as well as other provisions of this Title.
d. Expansions Allowed: Notwithstanding the above, individual multi -family unit sizes may be
increased by extinguishing Historic Transferable Development Right Certificates
("certificate" or "certificates"), subject to the following:
1. The transfer ratio is five hundred (500) square feet of net livable area for each certificate
that is extinguished.
2. The additional square foot age accrued may be applied to multiple units. However, the
maximum individual unit size attainable by transferring development rights is two
thousand five hundred (2,500) square feet of net livable area (i.e., no more than five
hundred (500) additional squ are feet may be applied per unit).
3. This incentive applies only to individual unit size. Transferring development rights does
not allow an increase in the Floor Area Ratio (FAR) of the lot or the use.
There is no limitation to unit size for affordable multi -family housing. The existing residential
structure is fully conforming to these requirements.
(13) Commercial/residential ratio: When development includes mixed-uses, the total residential net
livable area shall be no greater than one hundred fifty percent (150%) the total commercial net
leasable and lodging net livable area located on the same parcel.
Not applicable.
(e) Compliance with City of Aspen Charter. Any property located east of Castle C reek that was in the
Mixed-Use (MU) zone district on January 1, 2015, is subject to the provisions of Article XIII Section
13.14, Voter authorization of certain land use approvals , of the City of Aspen Charter.
Not applicable at this location.
57
CITY OF ASPEN COMMUNITY DEVELOPMENT DEPARTMENT
City of Aspen|130 S. Galena St.|(970) 920 5090 April 2020
LAND USE APPLICATION
APPLICANT:
REPRESENTIVATIVE:
Description: Existing and Proposed Conditions
Review: Administrative or Board Review
Required Land Use Review(s):
Growth Management Quota System (GMQS) required fields:
Net Leasable square footage Lodge Pillows Free Market dwelling units
Affordable Housing dwelling units Essential Public Facility square footage
Have you included the following? FEES DUE: $
Pre-Application Conference Summary
Signed Fee Agreement
HOA Compliance form
All items listed in checklist on PreApplication Conference Summary
Name:
Address:
Phone#: email:
Address:
Phone #: email:
Name:
Project Name and Address:
Parcel ID # (REQUIRED)
58
2,336
389.4
Legend
1:
WGS_1984_Web_Mercator_Auxiliary_Sphere
Feet0389.4194.68
Notes
Pitkin Maps & More
THIS MAP IS FOR INFORMATIONAL PURPOSES.
Pitkin County GIS makes no warranty or guarantee
concerning the completeness, accuracy, or reliability
of the content represented.
Map Created on 3:09 PM 03/16/23 at http://www.pitkinmapsandmore.com
State Highway
Road Centerline 4K
Primary Road
Secondary Road
Service Road
Full Address
Parcel Boundary
Rivers and Creeks
Continuous
Intermittent
River, Lake or Pond
Town Boundary
Federal Land Boundary
BLM
State of Colorado
USFS
59
Report Created: 3/16/2023 3:37:41 PM
Parcel ID: 273512454003Pitkin County Parcel Report
Woody Creek-Roaring Fork River
Main Street Historic District
No Zoning Overlay on this parcel
AACP
Not within a Caucus Area
Watershed Drainage
Historic District
Zone District Overlays
Master Plan Area
Caucus
Boundaries
Pitkin County Library
Aspen School District No. 1 (RE)
Aspen Fire Protection District
City of Aspen Water Service Area
Aspen Consolidated Sanitation District
Library District
School District
Fire District
Water District
Sewer System
Services
Land Use Category
2226 Sq. FeetImprovements
Assessor's Information
Township, Range, Section
7405.2 Sq. Feet
205 W MAIN ST
Aspen
GIS Parcel Size
Address (Assessor's Records)
Jurisdiction
Property Information
1112: Residential-Single Family Residence
205 W MAIN Address (GIS Points)205 W MAIN ST
605 W MAIN ST #2 ASPEN, CO 81611
R000276
CONSERVATION HOUSING PARTNERS LLCOwner
Account
Owner Address
T:10, R:85, S:12
Subdivision: CITY AND TOWNSITE OF ASPEN Block: 52 Lot: H AND:- Lot: I & E 15'
OF LOT G
Legal Description
No Zoning District on this parcelZone District
60
1
2
U.S. House of Representatives District
Board of County Commissioners District(s)
State Senate District
State House District
Voting Precinct
Voting Information
3
5
57
Hallam Lake, Reeder, Mill Street Parcel, Little Cloud, Marolt Ranch, Little Cloud Park,
Jenny Adair Park, Center Lode Mining Claim, Barbee
Hunter Creek Extension, Racetrack, Villas, W Hallam St, S Seventh St, Trueman ,
Recycle Center, Rio Grande Park, Summit St Cutoff , Post Office, E Hallam St,
Courthouse, Ajax - Little Cloud connector, John Denver Sanctuary, Puppy Smith, Red
Mountain Rd, E Hopkins Ave, Little Cloud, Scotties, Midland Trail , W Hopkins Ave, Ajax,
Aspen Mountain Rd, Bergman, Rio Grande, Marolt, Top of Mill Crossover, Trueman, Red
Brick, Music Tent, Midland - 3rd St, Lone Pine, W Hopkins Path
Wagner Park, Pioneer Park, Hillyard Park, Triangle Park, Koch Lumber Park, Wheeler
Park, Conner Memorial Park, Clapper Park, Francis Whitaker Park, Veterans Park,
Paepcke Park, Yellow Brick School Park, Willoughby ParK, Library Plaza, Armstrong AKA
Crash Point, Lift One A Park, Rio Grande Skate Park, Rio Grande Park, John Denver
Sanctuary, Newbury Park, Cooper Park, Hyman Park, Silver Circle Ice Rink, Mary B
Open Spaces Nearby (1/2 Mile)
Trails Nearby (1/2 Mile)
Parks Nearby (1/2 Mile)
Public Amenities
Woody Creek-Roaring Fork River
Watershed Subbasin
Watershed Drainage
Historic District
Tax Information
Address
Retired Parcel
Documents
Parcel 273512454003
205 W MAIN ST
Brush Creek-Roaring Fork River
COUNTY TV/FM TRANSLATOR
COUNTY HUMAN SERVICES
ASPEN CONSOLIDATED SANITA
ASPEN VALLEY HOSPITAL
COLORADO MTN COLLEGE
Total
COUNTY ROAD & BRIDGE
ASPEN HISTORIC PARK & REC
COLORADO RIVER WATER CONS
PITKIN COUNTY LIBRARY
OPEN SPACE & TRAILS
HEALTHY COMMUNITY FUND
ROARING FORK TRANSP AUTH
ASPEN FIRE PROTECTION
ASPEN AMBULANCE DISTRICT
ASPEN SCHOOL DISTRICT
PITKIN COUNTY GENERAL FND
CITY OF ASPEN
2.297
0.3
5.093
1.436
0.501
8.844
0.956
2.422
3.75
0.177
2.638
0.094
0.287
4.013
2.65
0.065
0.502
$790.20
$105.57
$484.02
$63.22
$19.81
$555.88
$60.48
$201.45
$510.35
$302.59
$37.30
$13.70
$845.62
$1,073.20
$1,863.62
$105.78
$558.41
AmountAuthorityMill Levy
36.025 $7,591.20
No Retired
61
Pitkin County GIS presents the information and data on this report as a service to the public. Every effort has been
made to ensure that the information and data contained in the report is accurate, but the accuracy may change. The
information maintained by the County may not be complete as to mineral estate ownership and that information
should be determined by separate legal and property analysis.
http://www.pitkinmapsandmore.com
Pitkin County GIS makes no warranty or guarantee concerning the completeness, accuracy, or reliability of the
content at this site or at other sites to which we link. Assessing accuracy and reliability of information and data is the
sole responsibility of the user. The user understands he or she is solely responsible and liable for use, modification,
or distribution of any information or data obtained on this web site.
Disclaimer
Data is presented in WGS 1984 Web Mercator. Size, shape, measurement and overlay of features may be distorted.
In some cases, multiple results could be valid; for example, Zoning. In other cases, a parcel may cross over the
boundary of more than one data area, for example, multiple Precincts. Visit the Pitkin County GIS Department at
62
DRAWING ISSUEDRAWN BY:PROJECT No:2125CPFDUE DILIGENCE 2021-08-26CONCEPTUAL 2021-10-21HPC APPLICATION 2022-05-12205 WEST MAIN | ASPEN CO205 WEST MAINAll ideas, designs, arrangements and plansindicated or represented by this drawing areowned by and are the property of David JohnstonArchitects, PC and developed for use and inconjunction with the specified project. Noneof the ideas, designs, arrangements or plansshall be used by or disclosed for any purposewhatsoever without the written authorizationof David Johnston Architects, PC.119 South Spring St.Suite 203Aspen, CO 81611 970-925-3444 970-920-2186TELFAXA1.01SITE PLAN | EXISTING |1:10AFFORDABLE HOUSINGSheet No.SCALE: 1' = 1'-0"1SITE PLAN | EXISTING | 1:100 1/2'' 1'' 2''
63
DRAWING ISSUE
DRAWN BY:
PROJECT No:2125
CPF
DUE DILIGENCE 2021-08-26
CONCEPTUAL 2021-10-21
HPC OPTION B 2022-11-07
HPC-RELOCATION 2023-03-10205 WEST MAIN | ASPEN CO 205 WEST MAIN All ideas, designs, arrangements and plans
indicated or represented by this drawing are
owned by and are the property of David Johnston
Architects, PC and developed for use and in
conjunction with the specified project. None
of the ideas, designs, arrangements or plans
shall be used by or disclosed for any purpose
whatsoever without the written authorization
of David Johnston Architects, PC.
119 South Spring St.
Suite 203
Aspen, CO 81611
970-925-3444
970-920-2186
TEL
FAX
A1.03
SITE PLAN | RELOCATION
PLAN | 1:10 AFFORDABLE HOUSING Sheet No.
N
PROPOSED HISTORIC STRUCTURE FOOTPRINT15'-219/64"EXISTING PARKING
-TO BE REMOVED
W. MAIN STREET
100.00' PUBLIC R.O.W.S. FIRST STREET75.45' PUBLIC R.O.W.S 75°09'11" E 75.00' (R)
N 75°09'11" W 75.00' (R)18.324.6
6.2 21.010.97.24.5
25.1 20.31.2
10.212.2
ALLEY BLOCK 52
21.01' PUBLIC R.O.W.
A L L E Y
CONCRETE SIDEWALK
PROPERTY LINE
PROPERTY LINE
LIGHTWELLLIGHTWELLFOOTPRINT OF EXSTING
HISTORIC STRUCTURES 14°50'49" W 100.00' (R)SETBACK
SCALE: 1" = 10'1 SITE PLAN | PROPOSED HISTORIC RELOCATION | 1:10
0 5'10'20'
64
PRELIMINARYSCHEMATICPLANL0.10DATE:DRAWN BY:CHECKED BY:ISSUE:HISTORY:BAJSHEET TITLE:MAIN STREETVICTORIANFOR PLANNINGPURPOSES ONLYNOT FOR CONSTRUCTION10.24.2022ADDRESS:205 W. MAIN ST.ASPEN, CO 81611PARCEL #---------------PSRDATE04.20.2022ISSUEHPCSTAMP PER DISCIPLINEPITKIN COUNTY STAMPS0'3'6'12'SCALE: 1"= 6'-0"NORTHDRAFTIVORY SILK JAPANESE TREE LILACRHAPSODY BLUE HYDRANGEAROCKY MOUNTAIN COLUMBINEFIREFLY CORAL BELLSLILY -OF-THE-VALLEYORCHID FROST DEAD NETTLEBELGARD PERMEABLE PAVERFLAGSTONE STEPPERS &FLAGSTONE PATIOIVORY SILK JAPANESE TREELILAC, TYP.FIREFLY CORAL BELLS, TYP.DEAD NETTLE, TYP.RHAPSODY BLUE HYDRANGEA,TYP.ROCKY MOUNTAIN COLUMBINE,TYP.LILY-OF-THE-VALLEY,TYP.EXISTING TREES TO REAMINPROPOSED FLAGSTONESTEPPERS, TYP.PROPOSED PERMEABLEPAVERS, TYP.LAWNLAWNPROPERTY LINEPROPERTY LINESETBACKHISTORIC RESOURCETBDFLAGSTONE PATIO, TYP.BIKE PARKINGBENCH, TYP.WWWWALLEYEXISTING SIDEWALKEXISTING SIDEWALKPROPOSED SIDEWALKPROPOSED DECIDUOUS TREETYP.TBDTBDCOBBLE MAINTENANCE BAND65
119 South Spring Street | Suite 203 | Aspen, CO
T 970.925.3444 C 517.881.5046
www.djarchitects.com
May 20, 2022
D. Brian Beazley
Stan Clauson
205 West Main Street Affordable Housing
Historic Structure Relocation Assessment
This letter serves as a document to confirm the proposed relocation and improvements to the
existing structure at 205 West Main Street in Aspen, CO. The proposed design is intending the
house to be lifted from the existing basement foundation and relocated to the NE corner of the lot.
The home was built in 1890 and moved from the west end of Aspen to this site in 1949. The
existing residence is a two-story gable framed structure with a single story shed roof structure to the
south. The structure will be set on a new basement foundation, shored and gutted to incorporate
the new proposed floorplans. The roof structure will have to be brought up to current structural
code. Based upon observations, the existing structure appears to be sound and should be able to
withstand the move to the new location. The move should be conducted by a qualified building
moving company that is experienced in moving similar historic structures. This review was based
upon visual observations only.
Regards,
D. Brian Beazley, Architect-AIA
DATE
BY
TO
CC
PROJECT
SUBJECT
COMMENTS
66
CITY OF ASPEN COMMUNITY DEVELOPMENT DEPARTMENT
City of Aspen|130 S. Galena St.|(970) 920 5090 April 2020
Agreement to Pay Application Fees
An agreement between the City of Aspen (“City”) and
Address of Property:
Please type or print in all caps
Property Owner Name: Representative Name (if different from Property Owner):
Billing Name and Address - Send Bills to:
Contact info for billing: e-mail: Phone:
I understand that the City has adopted, via Ordinance No. 20, Series of 2020, review fees for Land Use applications, and
payment of these fees is a condition precedent to determining application completeness. I understand that as the property
owner, I am responsible for paying all fees for this development application.
For flat fees and referral fees: I agree to pay the following fees for the services indicated. I understand that these flat fees
are non-refundable.
$. flat fee for . $. flat fee for
$. flat fee for . $. flat fee for
For deposit cases only: The City and I understand that because of the size, nature, or scope of the proposed project, it is not
possible at this time to know the full extent or total costs involved in processing the application. I understand that additional
costs over and above the deposit may accrue. I understand and agree that it is impracticable for City staff to complete
processing, review, and presentation of sufficient information to enable legally required findings to be made for project
consideration unless invoices are paid in full.
The City and I understand and agree that invoices sent by the City to the above listed billing address and not returned to the
City shall be considered by the City as being received by me. I agree to remit payment within 30 days of presentation of an
invoice by the City for such services.
I have read, understood, and agree to the Land Use Review Fee Policy, including consequences for non-payment. I agree to
pay the following initial deposit amounts for the specified hours of staff time. I understand that payment of a deposit does
not render an application complete or compliant with approval criteria. If actual recorded costs exceed the initial deposit, I
agree to pay additional monthly billings to the City to reimburse the City for processing my application at the hourly rates
hereinafter stated.
$ deposit for hours of Community Development Department staff time. Additional time
above the deposit amount will be billed at $325.00 per hour.
$ deposit for hours of Engineering Department staff time. Additional time above the
deposit amount will be billed at $325.00 per hour.
City of Aspen:
Phillip Supino, AICP
Community Development Director
City Use:
Fees Due: $ Received $
Case #
Signature:
PRINT Name:
Title:
67
Michael Brown, Manager
Conservation Housing Partners LLC
605 W. Main St., Suite 2
Aspen, CO 81611
970-544-4196
16 March 2023
Mr. Kevin Rayes, Planner
Community Development Department
City of Aspen
427 Rio Grand Place
Aspen, CO 81611
Re: Authorization to Submit Land Use Application / Minor Development and Relocation
Dear Mr. Rayes:
This letter is to certify that I, Michael Brown, Manager of Conservation Housing Partners LLC, owner
of the property located at 205 W. Main Street, give Clauson Rawley Associates, Inc. and its staff
permission to represent us in discussions with the City of Aspen regarding applications for this
property. If you should have any questions regarding this matter, please contact me.
If you should have any questions regarding this matter, please do not hesitate to contact me.
Their contact information is as follows:
Stan Clauson, FAICP, ASLA
Clauson Rawley Associates, Inc.
400 E. Main Street, Suite 203
Aspen, CO 81611
Tel 970-925-2323 (o)
Tel 970-274-3265 (c)
Fax 970-920-1628
stan@cra-designplanning.com
Very Truly Yours,
________________________________________
Michael Brown, Manager
Conservation Housing Partners LLC
68
April 2020 City of Aspen|130 S. Galena St.|(970) 920 5090
CITY OF ASPEN COMMUNITY DEVELOPMENT DEPARTMENT
Homeowner Association Compliance Policy
All land use applications within the City of Aspen are required to include a Homeowner Association
Compliance Form (this form) certifying that the scope of work included in the land use application
complies with all applicable covenants and homeowner association policies. The certification must be
signed by the property owner or Attorney representing the property owner.
Property
Owner (“I”):
Name:
Email: Phone No.:
Address of
Property:
(subject of
application)
I certify as follows: (pick one)
□This property is not subject to a homeowner association or other form of private c ovenant.
□This property is subject to a homeowner association or private covenant, and the improvements proposed in this land use application do not require approval by the homeowners association or covenant beneficiary.
□This property is subject to a homeowners association or private covenant and the improvements proposed in this land use application have been approved by the homeowners a ssociation or covenant beneficiary.
I understand this policy and I understand the City of Aspen does not interpret, enforce, or manage the
applicability, meaning or effect of private covenants or homeowner association rules or bylaws. I
understand that this document is a public document.
Owner signature: Date:
Owner printed name:
or,
Attorney signature: Date:
Attorney printed name:
69
This page is only a part of a 2016 ALTA® Commitment for Title Insurance issued by First American Title Insurance Company. This Commitment is not
valid without the Notice; the Commitment to Issue Policy; the Commitment Conditions; Schedule A; Schedule B, Part I—Requirements; Schedule B,
Part II—Exceptions; and a counter-signature by the Company or its issuing agent that may be in electronic form.
Copyright 2006-2016 American Land Title Association. All rights reserved.
The use of this Form (or any derivative thereof) is restricted to ALTA licensees and
ALTA members in good standing as of the date of use. All other uses are
prohibited. Reprinted under license from the American Land Title Association.
Form 5030000 (1-31-17)Page 1 of 16 ALTA Commitment for Title Insurance (8-1-16)
ALTA Commitment for Title Insurance
ISSUED BY
First American Title Insurance Company
Commitment
COMMITMENT FOR TITLE INSURANCE
Issued By
FIRST AMERICAN TITLE INSURANCE COMPANY
NOTICE
IMPORTANT—READ CAREFULLY: THIS COMMITMENT IS AN OFFER TO ISSUE ONE OR MORE TITLE
INSURANCE POLICIES. ALL CLAIMS OR REMEDIES SOUGHT AGAINST THE COMPANY INVOLVING THE
CONTENT OF THIS COMMITMENT OR THE POLICY MUST BE BASED SOLELY IN CONTRACT.
THIS COMMITMENT IS NOT AN ABSTRACT OF TITLE, REPORT OF THE CONDITION OF TITLE, LEGAL OPINION,
OPINION OF TITLE, OR OTHER REPRESENTATION OF THE STATUS OF TITLE. THE PROCEDURES USED BY
THE COMPANY TO DETERMINE INSURABILITY OF THE TITLE, INCLUDING ANY SEARCH AND EXAMINATION,
ARE PROPRIETARY TO THE COMPANY, WERE PERFORMED SOLELY FOR THE BENEFIT OF THE COMPANY,
AND CREATE NO EXTRACONTRACTUAL LIABILITY TO ANY PERSON, INCLUDING A PROPOSED INSURED.
THE COMPANY’S OBLIGATION UNDER THIS COMMITMENT IS TO ISSUE A POLICY TO A PROPOSED INSURED
IDENTIFIED IN SCHEDULE A IN ACCORDANCE WITH THE TERMS AND PROVISIONS OF THIS COMMITMENT.
THE COMPANY HAS NO LIABILITY OR OBLIGATION INVOLVING THE CONTENT OF THIS COMMITMENT TO ANY
OTHER PERSON.
COMMITMENT TO ISSUE POLICY
Subject to the Notice; Schedule B, Part I—Requirements; Schedule B, Part II—Exceptions; and the Commitment
Conditions,First American Title Insurance Company, a Colorado Corporation (the "Company"), commits to issue the
Policy according to the terms and provisions of this Commitment. This Commitment is effective as of the Commitment
Date shown in Schedule A for each Policy described in Schedule A, only when the Company has entered in Schedule A
both the specified dollar amount as the Proposed Policy Amount and the name of the Proposed Insured.
If all of the Schedule B, Part I—Requirements have not been met within six months after the Commitment Date, this
Commitment terminates and the Company’s liability and obligation end.
First American Title Insurance Company
If this jacket was created electronically, it constitutes an original document.
70
This page is only a part of a 2016 ALTA® Commitment for Title Insurance issued by First American Title Insurance Company. This Commitment is not
valid without the Notice; the Commitment to Issue Policy; the Commitment Conditions; Schedule A; Schedule B, Part I—Requirements; Schedule B,
Part II—Exceptions; and a counter-signature by the Company or its issuing agent that may be in electronic form.
Copyright 2006-2016 American Land Title Association. All rights reserved.
The use of this Form (or any derivative thereof) is restricted to ALTA licensees and
ALTA members in good standing as of the date of use. All other uses are
prohibited. Reprinted under license from the American Land Title Association.
Form 5030000 (1-31-17)Page 2 of 16 ALTA Commitment for Title Insurance (8-1-16)
COMMITMENT CONDITIONS
1.DEFINITIONS
(a) "Knowledge" or "Known": Actual or imputed knowledge, but not constructive notice imparted by the Public
Records.
(b) "Land": The land described in Schedule A and affixed improvements that by law constitute real property. The
term "Land" does not include any property beyond the lines of the area described in Schedule A, nor any right, title,
interest, estate, or easement in abutting streets, roads, avenues, alleys, lanes, ways, or waterways, but this does
not modify or limit the extent that a right of access to and from the Land is to be insured by the Policy.
(c) "Mortgage": A mortgage, deed of trust, or other security instrument, including one evidenced by electronic means
authorized by law.
(d) "Policy": Each contract of title insurance, in a form adopted by the American Land Title Association, issued or to
be issued by the Company pursuant to this Commitment.
(e) "Proposed Insured": Each person identified in Schedule A as the Proposed Insured of each Policy to be issued
pursuant to this Commitment.
(f) "Proposed Policy Amount": Each dollar amount specified in Schedule A as the Proposed Policy Amount of each
Policy to be issued pursuant to this Commitment.
(g) "Public Records": Records established under state statutes at the Commitment Date for the purpose of imparting
constructive notice of matters relating to real property to purchasers for value and without Knowledge.
(h) "Title": The estate or interest described in Schedule A.
2. If all of the Schedule B, Part I—Requirements have not been met within the time period specified in the Commitment
to Issue Policy, this Commitment terminates and the Company’s liability and obligation end.
3. The Company’s liability and obligation is limited by and this Commitment is not valid without:
(a) the Notice;
(b) the Commitment to Issue Policy;
(c) the Commitment Conditions;
(d) Schedule A;
(e) Schedule B, Part I—Requirements;
(f) Schedule B, Part II—Exceptions; and
(g) a counter-signature by the Company or its issuing agent that may be in electronic form.
4.COMPANY’S RIGHT TO AMEND
The Company may amend this Commitment at any time. If the Company amends this Commitment to add a defect,
lien, encumbrance, adverse claim, or other matter recorded in the Public Records prior to the Commitment Date, any
liability of the Company is limited by Commitment Condition 5. The Company shall not be liable for any other
amendment to this Commitment.
5.LIMITATIONS OF LIABILITY
(a) The Company’s liability under Commitment Condition 4 is limited to the Proposed Insured’s actual expense
incurred in the interval between the Company’s delivery to the Proposed Insured of the Commitment and the
delivery of the amended Commitment, resulting from the Proposed Insured’s good faith reliance to:
(i) comply with the Schedule B, Part I—Requirements;
(ii) eliminate, with the Company’s written consent, any Schedule B, Part II—Exceptions; or
(iii) acquire the Title or create the Mortgage covered by this Commitment.
(b) The Company shall not be liable under Commitment Condition 5(a) if the Proposed Insured requested the
amendment or had Knowledge of the matter and did not notify the Company about it in writing.
(c) The Company will only have liability under Commitment Condition 4 if the Proposed Insured would not have
incurred the expense had the Commitment included the added matter when the Commitment was first delivered to
the Proposed Insured.
71
This page is only a part of a 2016 ALTA® Commitment for Title Insurance issued by First American Title Insurance Company. This Commitment is not
valid without the Notice; the Commitment to Issue Policy; the Commitment Conditions; Schedule A; Schedule B, Part I—Requirements; Schedule B,
Part II—Exceptions; and a counter-signature by the Company or its issuing agent that may be in electronic form.
Copyright 2006-2016 American Land Title Association. All rights reserved.
The use of this Form (or any derivative thereof) is restricted to ALTA licensees and
ALTA members in good standing as of the date of use. All other uses are
prohibited. Reprinted under license from the American Land Title Association.
Form 5030000 (1-31-17)Page 3 of 16 ALTA Commitment for Title Insurance (8-1-16)
(d) The Company’s liability shall not exceed the lesser of the Proposed Insured’s actual expense incurred in good faith
and described in Commitment Conditions 5(a)(i) through 5(a)(iii) or the Proposed Policy Amount.
(e) The Company shall not be liable for the content of the Transaction Identification Data, if any.
(f) In no event shall the Company be obligated to issue the Policy referred to in this Commitment unless all of the
Schedule B, Part I—Requirements have been met to the satisfaction of the Company.
(g) In any event, the Company’s liability is limited by the terms and provisions of the Policy.
6.LIABILITY OF THE COMPANY MUST BE BASED ON THIS COMMITMENT
(a) Only a Proposed Insured identified in Schedule A, and no other person, may make a claim under this
Commitment.
(b) Any claim must be based in contract and must be restricted solely to the terms and provisions of this Commitment.
(c) Until the Policy is issued, this Commitment, as last revised, is the exclusive and entire agreement between the
parties with respect to the subject matter of this Commitment and supersedes all prior commitment negotiations,
representations, and proposals of any kind, whether written or oral, express or implied, relating to the subject
matter of this Commitment.
(d) The deletion or modification of any Schedule B, Part II—Exception does not constitute an agreement or obligation
to provide coverage beyond the terms and provisions of this Commitment or the Policy.
(e) Any amendment or endorsement to this Commitment must be in writing and authenticated by a person authorized
by the Company.
(f) When the Policy is issued, all liability and obligation under this Commitment will end and the Company’s only
liability will be under the Policy.
7.IF THIS COMMITMENT HAS BEEN ISSUED BY AN ISSUING AGENT
The issuing agent is the Company’s agent only for the limited purpose of issuing title insurance commitments and
policies. The issuing agent is not the Company’s agent for the purpose of providing closing or settlement services.
8.PRO-FORMA POLICY
The Company may provide, at the request of a Proposed Insured, a pro-forma policy illustrating the coverage that the
Company may provide. A pro-forma policy neither reflects the status of Title at the time that the pro-forma policy is
delivered to a Proposed Insured, nor is it a commitment to insure.
9.ARBITRATION
The Policy contains an arbitration clause. All arbitrable matters when the Proposed Policy Amount is $2,000,000 or
less shall be arbitrated at the option of either the Company or the Proposed Insured as the exclusive remedy of the
parties. A Proposed Insured may review a copy of the arbitration rules at http://www.alta.org/arbitration.
72
This page is only a part of a 2016 ALTA® Commitment for Title Insurance issued by First American Title Insurance Company. This Commitment is not
valid without the Notice; the Commitment to Issue Policy; the Commitment Conditions; Schedule A; Schedule B, Part I—Requirements; Schedule B,
Part II—Exceptions; and a counter-signature by the Company or its issuing agent that may be in electronic form.
Copyright 2006-2016 American Land Title Association. All rights reserved.
The use of this Form (or any derivative thereof) is restricted to ALTA licensees and
ALTA members in good standing as of the date of use. All other uses are prohibited.
Reprinted under license from the American Land Title Association.
Form 5033708-A (4-9-18)Page 4 of 16 ALTA Commitment for Title Insurance (8-1-16)
Colorado - Schedule A
ALTA Commitment for Title Insurance
ISSUED BY
First American Title Insurance Company
Schedule A
Transaction Identification Data for reference only:
Issuing Agent:Winter Van Alstine Issuing Office:Attorneys Title Insurance Agency
of Aspen, LLC
Issuing Office's ALTA® Registry ID: 1019587 Loan ID No.:
Commitment No.:21004842 Issuing Office File No.:21004842
Property Address:205 West Main Street, Aspen, CO 81611
SCHEDULE A
1. Commitment Date: October 8, 2021 at 07:45 AM
2. Policy or Policies to be issued: Amount Premium
A.ALTA Owners Policy (06/17/06)$5,500,000.00 $9,545.00
Proposed Insured:Conservation Housing Partners LLC, a Colorado limited liability company
Certificate of Taxes Due $25.00
Endorsements:
CO-110.1 (Delete 1, 2, 3, 4)$75.00
Additional Charges:$0
Total $9,645.00
3. The estate or interest in the land described or referred to in this Commitment is Fee simple.
4. The Title is, at the Commitment Date, vested in:
Karen C. Stevenson and Heather M. Chisholm
5. The land referred to in the Commitment is described as follows:
SEE EXHIBIT A ATTACHED HERETO
For informational purposes only, the property address is: 205 West Main Street, Aspen, CO 81611.
73
SCHEDULE A
(Continued)
This page is only a part of a 2016 ALTA® Commitment for Title Insurance issued by First American Title Insurance Company. This Commitment is not
valid without the Notice; the Commitment to Issue Policy; the Commitment Conditions; Schedule A; Schedule B, Part I—Requirements; Schedule B,
Part II—Exceptions; and a counter-signature by the Company or its issuing agent that may be in electronic form.
Copyright 2006-2016 American Land Title Association. All rights reserved.
The use of this Form (or any derivative thereof) is restricted to ALTA licensees and
ALTA members in good standing as of the date of use. All other uses are prohibited.
Reprinted under license from the American Land Title Association.
Form 5033708-A (4-9-18)Page 5 of 16 ALTA Commitment for Title Insurance (8-1-16)
Colorado - Schedule A
Attorneys Title Insurance Agency of Aspen, LLC
By:
Winter Van Alstine
Authorized Officer or Agent
FOR INFORMATION PURPOSED OR SERVICES IN CONNECTION WITH THIS COMMITMENT, CONTACT: Attorneys
Title Insurance Agency of Aspen, LLC,715 West Main Street, Suite 202, Aspen, CO 81611, Phone: 970 925-7328, Fax:
970 925-7348.
74
This page is only a part of a 2016 ALTA® Commitment for Title Insurance issued by First American Title Insurance Company. This Commitment is not
valid without the Notice; the Commitment to Issue Policy; the Commitment Conditions; Schedule A; Schedule B, Part I—Requirements; Schedule B,
Part II—Exceptions; and a counter-signature by the Company or its issuing agent that may be in electronic form.
Copyright 2006-2016 American Land Title Association. All rights reserved.
The use of this Form (or any derivative thereof) is restricted to ALTA licensees and
ALTA members in good standing as of the date of use. All other uses are prohibited.
Reprinted under license from the American Land Title Association.
Form 5030008-BI&BII (5-18-17)Page 6 of 16 ALTA Commitment for Title Insurance (8-1-16)
Colorado - Schedule BI & BII
ALTA Commitment for Title Insurance
ISSUED BY
First American Title Insurance Company
Schedule BI & BII
Commitment No: 21004842
SCHEDULE B, PART I
Requirements
All of the following Requirements must be met:
1.The Proposed Insured must notify the Company in writing of the name of any party not referred to in this
Commitment who will obtain an interest in the Land or who will make a loan on the Land. The Company may then
make additional Requirements or Exceptions.
2.Pay the agreed amount for the estate or interest to be insured.
3.Pay the premiums, fees, and charges for the Policy to the Company.
4.Documents satisfactory to the Company that convey the Title or create the Mortgage to be insured, or both, must
be properly authorized, executed, delivered, and recorded in the Public Records.
5.Payment of all taxes and assessments now due and payable as shown on a certificate of taxes due from the
County Treasurer or the County Treasurer's Authorized Agent.
6.Evidence that all assessments for common expenses, if any, have been paid.
7.Final Affidavit and Agreement executed by Owners and/or Purchasers must be provided to the Company
8.Special Warranty Deed must be sufficient to convey the fee simple estate or interest in the land described or
referred to herein, from Karen C. Stevenson and Heather M. Chisholm to Conservation Housing Partners LLC, a
Colorado limited liability company, the proposed insured, Schedule A, item 2A. NOTE: C.R.S. Section
38-35-109(2) required that a notation of the purchaser's legal address, (not necessarily the same as the property
address) be included on the face of the Deed to be recorded.
9.Release of the Deed of Trust from Edith S. Chisholm, Karen H. Chisholm, and Heather M. Chisholm, to the Public
Trustee of Pitkin County for the benefit of Norwest Mortgage Inc., to secure an indebtedness in the principal sum
of $144,000, and any other amounts and/obligations secured thereby, dated January 6, 1999 and recorded
January 19, 1999 as Reception No. 426731.
10.Record a Statement of Authority to provide prima facie evidence of existence of Conservation Housing Partners
LLC, a Colorado limited liability company, an entity capable of holding property, and the name of the person
authorized to execute instruments affecting title to real property as authorized by C.R.S. Section 38-30-172.
75
ALTA Commitment for Title Insurance
ISSUED BY
First American Title Insurance Company
Schedule BI & BII (Cont.)
Form 50-CO-Disclosure (4-1-16)Page 7 of 16 Disclosure Statement (5-1-15)
Colorado
11.Certificate of Good Standing from the Colorado Secretary of State for Conservation Housing Partners LLC, a
Colorado limited liability company.
12.A copy of the properly signed and executed Operating Agreement if written, for Conservation Housing Partners
LLC, a Colorado limited liability company, to be submitted to the Company for review.
13.Improvement Survey Plat sufficient in form, content and certification acceptable to the Company. Exception will be
taken to adverse matters disclosed thereby.
14.Receipt by the Company of the appropriate Lease Affidavit indemnifying the Company against any existing leases
or tenancies, and any and all parties claiming by, through or under said lessees.
15.This Title Commitment is subject to underwriter approval.
76
This page is only a part of a 2016 ALTA® Commitment for Title Insurance issued by First American Title Insurance Company. This Commitment is not
valid without the Notice; the Commitment to Issue Policy; the Commitment Conditions; Schedule A; Schedule B, Part I—Requirements; Schedule B,
Part II—Exceptions; and a counter-signature by the Company or its issuing agent that may be in electronic form.
Copyright 2006-2016 American Land Title Association. All rights reserved.
The use of this Form (or any derivative thereof) is restricted to ALTA licensees and
ALTA members in good standing as of the date of use. All other uses are prohibited.
Reprinted under license from the American Land Title Association.
Form 5030008-BI&BII (5-18-17)Page 8 of 16 ALTA Commitment for Title Insurance (8-1-16)
Colorado - Schedule BI & BII
ALTA Commitment for Title Insurance
ISSUED BY
First American Title Insurance Company
Schedule BI & BII (Cont.)
Commitment No.: 21004842
SCHEDULE B, PART II
Exceptions
THIS COMMITMENT DOES NOT REPUBLISH ANY COVENANT, CONDITION, RESTRICTION, OR LIMITATION
CONTAINED IN ANY DOCUMENT REFERRED TO IN THIS COMMITMENT TO THE EXTENT THAT THE SPECIFIC
COVENANT, CONDITION, RESTRICTION, OR LIMITATION VIOLATES STATE OR FEDERAL LAW BASED ON RACE,
COLOR, RELIGION, SEX, SEXUAL ORIENTATION, GENDER IDENTITY, HANDICAP, FAMILIAL STATUS, OR
NATIONAL ORIGIN.
The Policy will not insure against loss or damage resulting from the terms and provisions of any lease or easement
identified in Schedule A, and will include the following Exceptions unless cleared to the satisfaction of the Company:
1.Any facts, rights, interests or claims which are not shown by the Public Records, but which could be ascertained
by an inspection of the Land or by making inquiry of persons in possession thereof.
2.Easements, or claims of easements, not shown by the Public Records.
3.Discrepancies, conflicts in boundary lines, shortage in area, encroachments, and any facts which a correct land
survey and inspection of the Land would disclose, and which are not shown by the Public Records.
4.Any lien, or right to a lien, for services, labor or material theretofore or hereafter furnished, imposed by law and not
shown in the Public Records.
5.Any defect, lien, encumbrance, adverse claim, or other matter that appears for the first time in the Public Records
or is created, attaches, or is disclosed between the Commitment Date and the date on which all of the Schedule B,
Part I—Requirements are met.
Note: Exception number 5. will be removed from the policy provided the Company conducts the closing and
settlement service for the transaction identified in the commitment
6.Any and all unpaid taxes, assessments and unredeemed tax sales.
NOTE: This exception will not appear on the final title policy upon payments of taxes and premiums.
7.Intentionally deleted.
8.Any water rights, claims of title to water, in, on or under the Land.
9.Taxes and assessments for the year 2021, and subsequent years, a lien not yet due or payable.
77
ALTA Commitment for Title Insurance
ISSUED BY
First American Title Insurance Company
Schedule BI & BII (Cont.)
Form 50-CO-Disclosure (4-1-16)Page 9 of 16 Disclosure Statement (5-1-15)
Colorado
10."That no title shall be hereby acquired to any mine of gold, silver, cinnabar or copper, or to any valid mining claim
or possession held under existing laws" as described in the Deed dated January 3, 1888, and recorded January 8,
1888 in Book 59 at Page 243 as Reception No. 021983.
11.Reservations and exceptions specified under the Act authorizing the issuance of the Patent for the City and
Townsite of Aspen, recorded March 1, 1897, in Book 139 at Page 216 as Reception No. 060156.
12.Any and all notes, easements and recitals as disclosed on the Official Map of the City of Aspen recorded
December 16, 1959, as Reception No. 109023.
13.Terms, conditions, provisions, agreements and obligations specified under Ordinance No. 6 (series of 1959, An
Ordinance Accepting a Map Entitled "Official Map of the City of Aspen, Pitkin County, State of Colorado," as the
Official Map of the City of Aspen: Providing for Dedication of all Streets and Alleys, Except Such Streets and
Alleys Heretofore Vacated; And Providing for the Filing of Said Map, Field Notes, and Supplemental Plats with the
Clerk and Recorder for Pitkin County, dated November 2, 1959, and recorded December 18, 1959, in Book 189 at
Page 354 as Reception No. 109043; and any and all notes, easements and recitals as disclosed on the Willets
Map recorded November 12, 1969 in Plat Book 4 at Page 27 as Reception No. 137902.
14.Terms, conditions, provisions, agreements and obligations specified under the Accessory Dwelling Unit Deed
Restriction dated November 2, 1994, recorded December 6, 1994, in Book 768 at Page 781, as Reception No.
376974.
15.Intentionally deleted.
16.Terms, conditions, provisions, agreements and obligations specified under the Revocable Encroachment Licenses
recorded July 7, 2003, as Reception Nos.484973,484974, and 484975.
17.Terms, conditions, provisions, agreements and obligations specified under the License Agreement dated January,
2018, recorded January 18, 2018, as Reception No. 644528.
18.Any loss or damage due to the following matters as disclosed on the Improvement Survey Plat, provided by Aspen
Survey, dated July 28, 2021, as File No. 2107124:
1. Encroachment of the Concrete Drive onto the Land from the adjacent property to the West.
2. Any right, title, interest or claims of interest based upon the fence lines not corresponding to the property lines.
3. Boardwalk encroachment into Block 52 alley.
19.Any existing leases or tenancies, and any and all parties claiming by, through or under said lessees.
NOTE: Upon receipt of a Lease Affidavit from Seller, this exception will not appear on the final title policy.
78
Form 5000000-EX (7-1-14)Page 10 of 16 Exhibit A
ALTA Commitment for Title Insurance
ISSUED BY
First American Title Insurance Company
Exhibit A
File No.: 21004842
The Land referred to herein below is situated in the County of Pitkin, State of Colorado, and is described as follows:
Lots H and I and the East fifteen (15') feet of Lot G, Block 52, CITY AND TOWNSITE OF ASPEN, Pitkin County, Colorado.
79
Form 50-CO-Disclosure (4-1-16)Page 11 of 16 Disclosure Statement (5-1-15)
Colorado
DISCLOSURE STATEMENT
Pursuant to C.R.S. 30-10-406(3)(a) all documents received for recording or filing in the Clerk and Recorder’s office shall contain
a top margin of at least one inch and a left, right and bottom margin of at least one-half of an inch. The Clerk and Recorder will
refuse to record or file any document that does not conform to the requirements of this section.
NOTE: If this transaction includes a sale of the property and the price exceeds $100,000.00, the seller must comply with the
disclosure/withholding provisions of C.R.S. 39-22-604.5 (Nonresident withholding).
NOTE: Colorado Division of Insurance Regulations 8-1-2 requires that “Every title insurance company shall be responsible to
the proposed insured(s) subject to the terms and conditions of the title commitment, other than the effective date of the title
commitment, for all matters which appear of record prior to the time of recording whenever the title insurance company, or its
agent, conducts the closing and settlement service that is in conjunction with its issuance of an owner’s policy of title insurance
and is responsible for the recording and filing of legal documents resulting from the transaction which was closed.
Pursuant to C.R.S. 10-11-122, the company will not issue its owner’s policy or owner’s policies of title insurance contemplated
by this commitment until it has been provided a Certificate of Taxes due or other equivalent documentation from the County
Treasurer or the County Treasurer’s authorized agent; or until the Proposed Insured has notified or instructed the company in
writing to the contrary.
The subject property may be located in a special taxing district. A Certificate of Taxes due listing each taxing jurisdiction shall be
obtained from the County Treasurer or the County Treasurer’s authorized agent. Information regarding special districts and the
boundaries of such districts may be obtained from the Board of County Commissioners, the County Clerk and Recorder, or the
County Assessor.
NOTE: Pursuant to CRS 10-11-123, notice is hereby given:
This notice applies to owner’s policy commitments containing a mineral severance instrument exception, or
exceptions, in Schedule B, Section 2.
A. That there is recorded evidence that a mineral estate has been severed, leased, or otherwise conveyed from the
surface estate and that there is a substantial likelihood that a third party holds some or all interest in oil, gas,
other minerals, or geothermal energy in the property; and
B. That such mineral estate may include the right to enter and use the property without the surface owner’s
permission.
NOTE: Pursuant to Colorado Division of Insurance Regulations 8-1-2, Affirmative mechanic’s lien protection for the
Owner may be available (typically by deletion of Exception no. 4 of Schedule B, Section 2 of the Commitment from the
Owner’s Policy to be issued) upon compliance with the following conditions:
A. The land described in Schedule A of this commitment must be a single family residence which includes a
condominium or townhouse unit.
B. No labor or materials have been furnished by mechanics or material-men for purposes of construction on the
land described in Schedule A of this Commitment within the past 6 months.
C. The Company must receive an appropriate affidavit indemnifying the Company against un-filed mechanic’s and
material-men’s liens.
D. The Company must receive payment of the appropriate premium.
E. If there has been construction, improvements or major repairs undertaken on the property to be purchased
within six months prior to the Date of the Commitment, the requirements to obtain coverage for unrecorded
liens will include: disclosure of certain construction information; financial information as to the seller, the
builder and or the contractor; payment of the appropriate premium, fully executed Indemnity Agreements
satisfactory to the company, and, any additional requirements as may be necessary after an examination of the
aforesaid information by the Company.
No coverage will be given under any circumstances for labor or material for which the insured has contracted for or
agreed to pay.
80
Form 50-CO-Disclosure (4-1-16)Page 12 of 16 Disclosure Statement (5-1-15)
Colorado
NOTE: Pursuant to C.R.S. 38-35-125(2) no person or entity that provides closing and settlement services for a real estate
transaction shall disburse funds as a part of such services until those funds have been received and are available for immediate
withdrawal as a matter of right.
NOTE: C.R.S. 39-14-102 requires that a real property transfer declaration accompany any conveyance document presented for
recordation in the State of Colorado. Said declaration shall be completed and signed by either the grantor or grantee.
NOTE: Pursuant to CRS 10-1-128(6)(a), It is unlawful to knowingly provide false, incomplete, or misleading facts or
information to an insurance company for the purpose of defrauding or attempting to defraud the company. Penalties
may include imprisonment, fines, denial of insurance and civil damages. Any insurance company or agent of an
insurance company who knowingly provides false, incomplete, or misleading facts or information to a policyholder or
claimant for the purpose of defrauding or attempting to defraud the policyholder or claimant with regard to a settlement
or award payable from insurance proceeds shall be reported to the Colorado division of insurance within the
department of regulatory agencies.
NOTE: Pursuant to Colorado Division of Insurance Regulations 8-1-3, notice is hereby given of the availability of an ALTA
Closing Protection Letter which may, upon request, be provided to certain parties to the transaction identified in the commitment.
Nothing herein contained will be deemed to obligate the company to provide any of the coverages referred to herein unless the
above conditions are fully satisfied.
81
TELEPHONE 970 925-7328 FACSIMILE 970 925-7348
ATTORNEYS TITLE INSURANCE AGENCY OF ASPEN, LLC
715 West Main Street, Suite 202
Aspen, CO 81611
Attorneys Title Insurance Agency of Aspen, LLC
Privacy Policy Notice
PURPOSE OF THIS NOTICE
Title V. of the Gramm-Leach-Bliley Act (GLBA) generally prohibits any financial institution, directly or through it affiliates,
from sharing non-public personal information about you with a nonaffiliated third party unless the institution provides you
with a notice of its privacy policies and practices, such as the type of information that it collects about you and the
categories of persons or entities to whom it may be disclosed. In compliance with the GLBA, we are providing you with
this document, which notifies you of the privacy policies and practices of Attorneys Title Insurance Agency of Aspen,
LLC.
We may collect nonpublic personal information about you from the following sources:
Information we receive from you, such as on application or other forms.
Information about your transactions we secure from out files, or from our affiliates or others.
Information we receive from a consumer reporting agency.
Information that we receive from others involved in your transaction, such as the real estate agent or lender.
Unless it is specifically stated otherwise in an amended Privacy Policy Notice, no additional nonpublic personal information
will be collected about you.
We may disclose any of the above information that we collect about our customers or former customer to our affiliates or
to nonaffiliated third parties as permitted by law.
We also may disclose this information about our customers or former customers to the following types of nonaffiliated
companies that perform marketing services on our behalf or with whom we have joint marketing agreements:
Financial service providers such as companies engaged in banking, consumer finance, securities and insurance.
Non-financial companies such as envelope stuffers and other fulfillment service providers.
WE DO NOT DISCLOSE ANY NONPUBLIC PERSONAL INFORMATION ABOUT YOU WITH ANYONE FOR ANY
PURPOSE THAT IS NOT SPECIFICALLY PERMITTED BY LAW.
We restrict access to nonpublic personal information about you to those employees who need to know that information in
order to provide products or services to you. We maintain physical, electronic, and procedural safeguards that comply with
federal regulations to guard your nonpublic personal information.
82
83
84
85
Pitkin County Mailing List of 300 Feet Radius
Pitkin County GIS presents the information and data on this web
site as a service to the public. Every effort has been made to
ensure that the information and data contained in this electronic
system is accurate, but the accuracy may change. The
information maintained by the County may not be complete as to
mineral estate ownership and that information should be
determined by separate legal and property analysis.
Pitkin County GIS makes no warranty or guarantee concerning
the completeness, accuracy, or reliability of the content at this
site or at other sites to which we link. Assessing accuracy and
reliability of information and data is the sole responsibility of the
user. The user understands he or she is solely responsible and
liable for use, modification, or distribution of any information or
data obtained on this web site.
This document contains a Mailing List formatted to be
printed on Avery 5160 Labels. If printing, DO NOT "fit to
page" or "shrink oversized pages." This will manipulate the
margins such that they no longer line up on the labels
sheet. Print actual size.
From Parcel: 273512454003 on 03/16/2023
Instructions:
Disclaimer:
http://www.pitkinmapsandmore.com
86
121 W BLEEKER LLC
ASPEN, CO 81611
121 W BLEEKER ST
132 W MAIN LLC
DENVER, CO 80202
1615 CALIFORNIA ST # 707
135 HOPKINS LTD
AUSTIN, TX 78738
12400 HWY 71 W #350-371
211 WEST MAIN LLC
ASPEN, CO 81611
323 W MAIN ST
212 WEST HOPKINS LLC
ASPEN, CO 81611
212 W HOPKINS AVE
220 WEST MAIN PARTNERS LLC
ASPEN, CO 81611
220 WEST MAIN ST STE 105
220 WEST MAIN STREET LLC
ASPEN, CO 81611
201 CASTLE RIDGE
220 WMAC LLC
ASPEN, CO 81612
PO BOX 8346
233 W BLEEKER LOTS ABC LLC
ASPEN, CO 81611
501 RIO GRANDE PL #204
235 W HOPKINS B LLC
BOCA RATON, FL 33432
250 S OCEAN BLVD # 14A
2401 BLAKE LLC
DENVER, CO 80202
1615 CALIFORNIA ST # 707
AJAX VIEW COMMERCIAL/NORTH STAR OFFICE
ASPEN, CO 81611
132 W MAIN ST
AML 103 LLC
ASPEN, CO 81611
605 W MAIN ST #2
AML 309 LLC
ASPEN, CO 81611
605 W MAIN ST #2
ASPEN CONDOS ASSOC
ASPEN, CO 81611
COMMON AREA
311 W MAIN ST
ASPEN HOMEOWNERS ASSOCIATION
ASPEN, CO 81611
311 W MAIN ST
ASPEN MAIN OFFICE CONDO ASSOC
ASPEN, CO 81611
220 W MAIN ST
ASPEN MEDICAL CENTER CONDO ASSOC
ASPEN, CO 81611
COMMON AREA
W MAIN ST
ASPEN MOUNTAIN LODGE UNIT 301 LLC
CONSHOHOCKEN, PA 19428
PO BOX 401
ASPEN SCHOOL DISTRICT #1
ASPEN, CO 81611
0235 HIGH SCHOOL RD
ASPEN SKIING COMPANY LLC
ASPEN, CO 81612
PO BOX 1248
ASPEN/PITKIN COUNTY HOUSING AUTHORITY
ASPEN, CO 81611
18 TRUSCOTT PL
BERGHOFF KRISTIN TRUST
INDIANAPOLIS, IN 46236
9112 WALNUT GROVE DR
BERGHOFF MICHAEL R TRUST
INDIANAPOLIS, IN 46236
9112 WALNUT GROVE DR
BETA PROPERTIES LLC
FORT COLLINS, CO 80525
1609 E HARMONY RD
BLEEKER LLC
CARBONDALE, CO 81623
111 PINNACLE CT
BLUEGREEN VACATIONS UNLIMITED INC
BOCA RATON, FL 33431
4960 CONFERENCE WY N #100
BROWDE KRISTEN PRATA
MIAMI, FL 33132
888 BISCAYNE BLVD #2401
CHOOKASZIAN DENNIS
WILMETTE, IL 60091
1100 MICHIGAN AVE
CRAWFORD ALBERT
SYRACUSE, NY 13204
201 SOLAR ST
87
DEAN FAMILY LTD PTSHP LLP
BOULDER, CO 80301
590 DELLWOOD AVE
DHM FAMILY TRST
ATLANTA, GA 30309
2288 PEACHTREE RD, NW #12
DIMITRIUS RALLI TRUST
PASADENA, CA 91101
530 S LAKE AVE #433
ELKMAX LLC
ASPEN, CO 81611
605 W MAIN ST #2
FCB LLC
SNOWMASS, CO 816549102
525 SHIELD O RD
FISH EILEEN
BOULDER, CO 80302
546 14TH ST
GARET CONDO ASSOC
ASPEN, CO 81611
400 E MAIN ST #2
GARMISCH LODGING LLC
ASPEN, CO 81611
605 W MAIN ST #2
GIBSON RESIDENCES LLC
ASPEN, CO 81611
605 W MAIN ST #2
GILDENHORN MICHAEL S
BETHESDA, MD 20816
5008 BALTON RD
GLICKMAN ADAM
SAN JUAN PUERTO RICO 00907-3122,
644 FERNANDEZ JUNCOS AVE #301
DISTRICT VIEW PLAZA MIRAMAR
GROVER FREDRICK W & PAULA J
ST PETERSBURG, FL 337043717
725 BRIGHTWATERG BLVD NE
GUNN ROBERT W FAMILY TRST
MARBLEHEAD, MA 01945
409 OCEAN AVE
GUNNING JANINE L
ASPEN, CO 81612
PO BOX 11705
GUNNING RALPH
ASPEN, CO 81612
PO BOX 11912
HARRISON MARK N
BOULDER, CO 80302
546 14TH ST
HAYMAX LODGING LLC
ASPEN, CO 81611
605 W MAIN ST #2
HITE ANGELA R FAMILY TRUST
WOODY CREEK, CO 81656
PO BOX 155
HITE HENRY HARRIS REVOC TRUST
WOODY CREEK, CO 81656
PO BOX 155
HOLTZMAN L BART & PATRICIA G
RANCHO MIRAGE, CA 92270
2 SURREY CT
HOTEL ASPEN CONDO ASSOC
ASPEN, CO 81611
COMMON AREA
110 W MAIN ST
INNSBRUCK CONDO ASSOC
ASPEN, CO 81611
233 W MAIN ST
JACOBY FAMILY LP
VERO BEACH, FL 32963
3383 OCEAN DR
JES 2002 GRANTOR TRUST
ASPEN, CO 81611
221 N STARWOOD DR
JLR QPRT TRUST
CORAL GABLES, FL 33156
355 MARQUESA DR
JOBLON MATTHEW
ENGLEWOOD, CO 80013
43 COVINGTON CT
KETTELKAMP FAM LIV TRUST
PUEBLO, CO 81003
2126 N ELIZABETH ST
KING LOUISE CONDO ASSOC
ASPEN, CO 81611
600 E HOPKINS AVE #203
KMGS REV TRUST
SAN FRANCISCO, CA 94118
3880 JACKSON ST
MARTIN SCOTT M
ASPEN, CO 81611
PO BOX 51
88
MELTON DAVID
ASPEN, CO 81611
135 W MAIN ST #A
MORGAN DONALD
ATLANTA, GA 30309
2288 PEACHTREE RD, NW #12
MOUNTAIN LODGE HOLDINGS LLC
ASPEN, CO 81611
605 W MAIN ST #2
NORTH STAR LODGE LLC
GRAND JUNCTION, CO 81505
633 24 RD
NORTHSTAR OFFICE BUILDING CONDO ASSOC
ASPEN, CO 81611
COMMON AREA
122 W MAIN ST
PAN ABODE CONDO ASSOC
ASPEN, CO 81611
211 W HOPKINS AVE
PESIKOFF DAVID
HOUSTON, TX 77098
1811 NORTH BLVD
RESIDENCES AT THE LITTLE NELL CONDO ASSOC INC
ASPEN, CO 81611
501 E DEAN ST
RILEY AMY CLARK
ASPEN, CO 81611
129 W BLEEKER ST
SAND KATHERINE M
ASPEN, CO 81612
PO BOX 51
SEVEN SEAS INVESTMENT LLC
WILMETTE, IL 60091
1120 MICHIGAN AVE
SHADOW MOUNTAIN DUPLEX CONDO ASSOC
ASPEN, CO 81611
COMMON AREA
W HOPKINS AVE
SHIELD JULIET E
ASPEN, CO 81611
221 N STARWOOD DR
SPERAW ENDEAVORS LLC
SNOWMASS VILLAGE, CO 81615
PO BOX 6575
SUREFOOT LC
PARK CITY, UT 84060
1500 KEARNS BLVD #110
TARADA LLC
RESTON, VA 201911530
1902 CAMPUS COMMONS DR #415
TEMPKINS HARRY & VIVIAN
MIAMI BEACH, FL 33139
605 LINCOLN RD #301
TIMBERLINE BANK
GRAND JUNCTION, CO 815054300
649 MARKET ST
TWIN COASTS LTD
BOCA RATON, FL 33432
433 PLAZA REAL #275
TYROL APARTMENTS LLC
ASPEN, CO 81611
200 W MAIN ST
TYROLEAN LODGE LLC
ASPEN, CO 81611
200 W MAIN ST
UTE HOUSING LLC
ASPEN, CO 81611
210 S GALENA ST
VALLEY EXCHANGE PROPERTIES LLC
ASPEN, CO 81611
122 W MAIN ST
VTF 220 LLC
BASALT, CO 81621
113 VALLEY CT
WEST HOPKINS LLC
POTOMAC, MD 20859
PO BOX 61510
WEST SIDE CONDO ASSOC
ASPEN, CO 81611
234 W HOPKINS AVE
WINER CAROL G
BETHESDA , MD 20817
6740 SELKIRK DR
89
2,400
400.0
Legend
1:
WGS_1984_Web_Mercator_Auxiliary_Sphere
Feet0400.0200.00
Notes
Pitkin Maps & More
THIS MAP IS FOR INFORMATIONAL PURPOSES.
Pitkin County GIS makes no warranty or guarantee
concerning the completeness, accuracy, or reliability
of the content represented.
Map Created on 2:58 PM 03/16/23 at http://www.pitkinmapsandmore.com
State Highway
Road Centerline 4K
Primary Road
Secondary Road
Service Road
Rivers and Creeks
Continuous
Intermittent
River, Lake or Pond
Town Boundary
Federal Land Boundary
BLM
State of Colorado
USFS
90
Page | 1
1. A minimum of six feet may be granted between the historic resource and new buildings if new
construction is limited to one-story in height.
PRE-APPLICATION CONFERENCE SUMMARY
DATE: February 23, 2023
PLANNER: Kevin Rayes | kevin.rayes@cityofaspen.com | 970.429.2797
PROJECT NAME AND ADDRESS: 205 W. Main Street | Affordable Housing Development | Development
Associated with the Historic Resource
PARCEL ID# 2735-124-54-003
REPRESENTATIVE: Stan Clauson | stan@cra-designplanning.com
DESCRIPTION: The subject property is located within the Mixed-Use (MU) zone district and the Main Street
Historic District. The property is improved with a designated landmark Victorian-era single family dwelling.
The resource was constructed circa 1890 and relocated to its current location in 1949.
The Applicant is interested in restoring the historic resource and developing multiple onsite affordable
housing units, within three separate structures – the historic resource and two new detached buildings. The
dwellings consist of one, two, and three-bedroom units. The units are intended to generate certificates of
affordable housing credits as they are not required for mitigation purposes. Based on preliminary
conversations, the units appear to meet minimal size and configuration requirements.
Pursuant to Land Use Code Section 26.470.090.d.3, when one hundred percent affordable housing is
proposed on a designated site containing a resource, a one-step review at HPC followed by an administrative
review may be pursued if the following conditions are met: (1) the resource is fully detached from all new
construction, (2) all non-historic additions are removed, (3) any new construction taller than one story is
distanced at least ten feet from the resource,1 and (4) all dimensional standards including but not limited
to setbacks, Floor Area Ratio, and height as prescribed within the MU zone district are met.
This pre-application sets forth the review process required at the Historic Preservation Commission f or
work impacting the historic resource.
HPC shall determine compliance with the following:
1. Land Use Code Section 26.415.070.c, Certificate of Appropriateness for a Minor Development
HPC shall review the work associated with demolition of non-historic additions and all work directly
affecting the historic resource.
2. Land Use Code Section 26.415.090, Relocation of Designated Historic Properties
• HPC may not deny Relocation but shall determine a siting for the historic structure that best meets
the City of Aspen Historic Preservation Design Guidelines while accommodating the allowed
development rights for the property. A conceptual site plan representing the full project may be
provided to assist with this review.
• Relocation may be granted for a resource within a front, rear, or side setback. New construction
may not be located within a setback.
• In consultation with the Historic Preservation Officer, the application must include a detailed
summary of repairs to historic fabric to be completed during construction, including exterior
materials, doors, and windows. The summary must also identify opportunities to restore an element
of the historic resource from an earlier condition that can be documented through photographs or
91
Page | 2
physical inspection. HPC may prioritize and require up to three of these to be completed during
construction.
• Site development shall incorporate the following (as applicable):
o A front walkway to the historic resource (no wider than the minimum required for
accessibility), that runs directly from the street to the door unless necessary to avoid a
preserved tree. The walkway may consist of gray concrete, brick, rectilinear stone, or
flagstone (as determined by HPC).
o Stormwater facilities and conveyances fully integrate with surrounding landscape when
viewed from the public right-of-way.
o The perimeter of the historic resource is bordered by gravel or a small diameter rock
planting strip one foot in width to protect from water. Plant material around the historic
resource cannot have an identified mature height taller than 42 inches (other than one
shrub or tree, placed with the mature size of the species in mind). Hardscape cannot be in
street facing yards around the historic resource (excluding the front walkway).
o Historically significant perimeter fences should be retained and repaired and cannot be
moved, removed, or inappropriately altered.
o New fences between the historic resource and the street shall not exceed 42 inches in height
and include a solid to void ratio of at least 50 percent.
RELEVANT LAND USE CODE SECTIONS:
Section Number Section Title
26.304 Common Development Review Procedures
26.415.070.c Certificate of Appropriateness for a Minor Development
26.415.090 Relocation of Designated Historic Properties
26.710.180 Mixed Use (MU) Zone District
For your convenience – links to the Land Use Application, the Land Use Code, and the Historic Preservation
Guidelines are below:
Land Use Application | Land Use Code | Historic Preservation Guidelines
REVIEW BY: Community Development staff for complete application and content
Engineering and Parks for referral comments
HPC for determinations
PUBLIC HEARING: Yes, Historic Preservation Commission
PLANNING FEES: $0 | Applications submitted for new projects that are 100 percent affordable
housing are eligible for a 100 percent fee waiver of Planning Review Fees
REFERRAL FEES: Engineering – $325 (additional hours may be billed as needed).
Parks - $975 Flat Fee
TOTAL DEPOSIT: $1,300
92
Page | 3
APPLICATION CHECKLIST – PLEASE EMAIL APPLICATION TO: kevin.rayes@aspen.gov
Completed Land Use Application and signed Fee Agreement (these documents are linked above).
HOA Compliance form (included in link above).
Pre-application Conference Summary (this document).
An 8 1/2 “ by 11” vicinity map locating the parcel within the City of Aspen.
Street address and legal description of the parcel on which development is proposed to occur,
consisting of a current certificate from a title insurance company, an ownership and encumbrance
report, or attorney licensed to practice in the State of Colorado, listing the names of all owners of
the property, and all mortgages, judgments, liens, easements, contracts and agreements affecting
the parcel, and demonstrating the owner’s right to apply for the Development Application. The
purpose of this requirement is to show that the Applicant has the authority to apply for a Land Use
Case.
Site improvement survey showing all existing conditions, including topography and vegetation,
certified by a registered land surveyor, licensed in the state of Colorado.
Applicant’s name, address, and phone number, within a letter signed by Applicant stating the
name, address and phone number of the representative authorized to act on behalf of the
applicant.
A written description of the proposal and an explanation in written, graphic, or model form of how
the proposed development complies with the review standards relevant to the development
application.
An accurate representation of all building materials and finishes to be used in the development.
Please include relevant cut-sheets for all materials for review.
Existing and proposed site plans showing setbacks, property boundaries and the extent of the
building relocation. On the proposed site plan, provide details responsive to the review
requirements, such as identifying the front walkway, fencing, landscaping around the resource,
and stormwater mitigation.
Supplemental materials to provide a visual description of the context surrounding the designated
historic property including photographs and other exhibits, as needed, to accurately depict
location and extent of proposed work.
A written report from a licensed engineer or architect regarding the soundness of the miner’s
cottage to be relocated and an explanation of the relocation plan.
Evidence of the financial ability to undertake the safe relocation, preservation, and repair of the
miner’s cottage through the posting of bonds or other financial measures deemed appropriate.
Optional: A conceptual site plan representing the full project may be provided to assist with this
review.
DISCLAIMER:
The foregoing summary is advisory in nature only and is not binding on the City. The summary is based on
current zoning, which is subject to change in the future, and upon factual representations that may or
may not be accurate. The summary does not create a legal or vested right.
93
Land Use Application Supplement
City of Aspen Historic Preservation Commission
20 April 2023
Location: 205 W. Main Street, Aspen, CO (PID# 273512454003)
Supplement to an Application for Historic Resource Relocation to provide
Affordable Housing.
Planning Representation: Architect:
94
205 W. Main Street / HPC Minor Development
(PID# 273512454003)
20 April 2023 P a g e | 1
Summary
As requested, the applicant is providing existing floor plans of the historic
residence located at 205 W. Main Street. We are also providing the proposed
elevations of the historic resource. The existing elevations are unchanged with the
exception of the removal of a non-historic addition at the rear southeast corner
of the structure. We are also providing photographs of the non-historic shed that
is also requested for removal.
The applicant is committed to repair and retain all exterior materials based on
field inspection with historic preservation staff. The applicant is also committed to
identify and complete up to three restoration actions, based on field inspection
by historic preservation staff. One of these actions will be the removal of the non-
historic addition and restoring the original building exterior envelope. Others may
be determined by field inspection.
A landscape restoration to the existing right-of-way along First Street will include
the removal of head-in off street gravel parking. This would be replaced by a
sidewalk and landscaped parkway with street trees as designated by the Parks
Department. Any replacement parking would be provided off of the alley
adjacent to the property.
Contents
1. Existing floor plans
2. Existing photo and proposed elevation
3. Photographs of the non-historic shed to be removed.
95
205 W. Main Street / HPC Minor Development
(PID# 273512454003)
20 April 2023 P a g e | 2
96
205 W. Main Street / HPC Minor Development
(PID# 273512454003)
20 April 2023 P a g e | 3
97
205 W. Main Street / HPC Minor Development
(PID# 273512454003)
20 April 2023 P a g e | 4
98
205 W. Main Street / HPC Minor Development
(PID# 273512454003)
20 April 2023 P a g e | 5
99
205 W. Main Street / HPC Minor Development
(PID# 273512454003)
20 April 2023 P a g e | 6
100
REGULAR MEETING HISTORIC PRESERVATION COMMISSION APRIL 26TH, 2023
Chairperson Thompson opened the regular meeting of the Aspen Historic Preservation Commission at
4:30pm.
Commissioners in attendance: Peter Fornell, Roger Moyer, Jodi Surfas, Jeffery Halferty and Kara
Thompson.
Commissioners not in attendance: Ms. Pitchford
Staff present:
Amy Simon, Planning Director
PJ Murray, Civil Engineer I
Sarah Roy, Red Brick Council of the Arts Director
Ben Anderson, Deputy Director of Community Development
Kate Johnson, Assistant City Attorney
Mike Sear, Deputy City Clerk
MINUTES: None.
PUBLIC COMMENTS:
Mr. David Scruggs commented on his repeated requests for HPC to hold hybrid meetings. He noted that
there were many other people who would appreciate the ability to attend virtually or in person. He
mentioned that he had appeared in front of City Council with this request and will continue to do so. He
said that the City Council holds fully hybrid meetings and has complete transparency.
Ms. Marsha Dowler supported Mr. Scruggs comments and request for hybrid meetings.
COMMISSION MEMBER COMMENTS:
Ms. Thompson said she didn’t believe there was a member of HPC that didn’t support having hybrid
meetings.
Mr. Moyer agreed with Mr. Scruggs and thought in the modern age holding hybrid meetings should be
possible.
Mr. Halferty echoed some of the concerns regarding holding hybrid meetings, but acknowledged it was
a staffing issue. He saw why it could be frustrating, as City Council holds hybrids meetings, but he
recognized that it was the board’s current protocol, and he stands by staff’s direction on it. He also
noted that it was nice to see some construction happening on the Main St. Bakery site.
Mr. Fornell addressed the public comments and hoped that they hesitate to use the word transparency
when speaking to City Council and staff as he did not believe that this Board is trying to do anything that
is less than transparent. He thought it was more of a topic of public comment availability rather than
transparency.
DISCLOSURE OF CONFLICTS OF INTEREST: None.
PROJECT MONITORING: Ms. Thompson asked Ms. Simon if they needed to reassign any of Ms.
Sanzone’s project, as she had resigned from the Commission. Ms. Simon said she would need to reassign
101
REGULAR MEETING HISTORIC PRESERVATION COMMISSION APRIL 26TH, 2023
a few projects that Ms. Sanzone was the sole monitor on but would be reaching out to Commissioners
soon.
CERTIFICATE OF NO NEGATIVE EFFECT: Ms. Simon stated that she had approved two certificates of no
negative effect. One for 530 W. Hallam where a lightwell was requested on the interior of the property.
The other was for 332 W. Main to add a new ADA ramp onto the porch.
STAFF COMMENTS: Ms. Johnson wanted to commend Ms. Simon as today marks her 30th year with the
City of Aspen. There was a big round of applause.
Ms. Simon reiterated that Ms. Sanzone had resigned her seat on HPC due to too many commitments.
She then noted that on May 5th there will be a site visit to 835 W. Main St. as it is being considered for
the National Registry of Historic Places.
She also wanted to make sure HPC was aware that staff is getting close to issuing permits for a number
of projects along Cooper Avenue from the Restoration Hardware building, to the other end of the block.
The entire length of the block besides Aspen Sports is about to go under renovation. Since there is
limited access to the sites, construction fencing will be installed on the length of the north side of the
mall to allow construction vehicles access.
Summary of City Council approval for Temporary Art downtown:
Ms. Roy started by introducing herself and Ms. Murray and described the project itself. It is a public art
project set to be installed in June and is a partnership with the Aspen Ideas Festival. It will be a
pavement art mural. Similar projects have been shown to improve pedestrian safety and can enhance
the neighborhood. It will also be a community-based project, with members of the public invited to help
create the mural. She then went over the details of the installation at Mill and Hyman.
Mr. Halferty asked about the project’s duration. Ms. Roy said the expectation is for it to last into the
winter, but it is based on traffic and snowplow activity. Ms. Murray stated that the proposed paint is low
toxicity and lead free.
Ms. Surfas said she thought it was a great idea and was excited to see it.
Mr. Fornell said he didn’t buy into it and while they say it will add to pedestrian safety, they are creating
something for a driver of a vehicle to look at instead of traffic and for pedestrians to stop in the middle
of the road and get their picture taken. He thought this would actually be a traffic generator. He then
asked how long the impact to parking spaces and pedestrian access would be during the installation. Ms.
Roy said it should be about 4-5 hours on Saturday, June 24th and then from about 8am to 6pm on
Sunday, June 25th.
CALL UP REPORTS: None.
SUBMIT PUBLIC NOTICE FOR AGENDA ITEMS: Ms. Johnson said that she reviewed public notice, and
that notice was provided per the code for agenda item.
NEW BUSINESS: 205 W. Main Street- Minor Development and Relocation, PUBLIC HEARING
Ms. Johnson went over the history regarding this project. She noted that an application came before
HPC for this property several months ago. That particular application has been withdrawn. She wanted
102
REGULAR MEETING HISTORIC PRESERVATION COMMISSION APRIL 26TH, 2023
to advise the members that now there is a new application and their decisions should be based on the
information presented in the new application and public comment related to the new application. She
cautioned against using information that may have been gained in a prior application to make decisions
regarding the new application. She noted that the new application was submitted under a new provision
in the Land Use Code and the applicant is entitled to request a review under those procedures.
Applicant Presentation: Stan Clauson, Clauson Rawley Associates
Mr. Clauson began by going over some of the background of the project including the original location of
the building and the relocation to its current location in 1949. He noted that it sits on an approximately
7,500 square foot a lot which is effectively 2.5 townsite lots. It was purchased in 2021 in order to pursue
an affordable housing project. He also noted that one of City Council’s goals is affordable housing. Next,
he went over the details of the relocation of the historic asset on the lot and noted that no variances are
required, and it is fully in compliance with setback requirements. He then showed site plans showing the
current location and then the proposed relocation to the NE corner of the property. The relocation will
reduce the asset’s footprint to one historic townsite lot. He detailed the removal of non-historic
additions and sheds on the property and noted that no additional floor area is part of this request. He
stated that all Historic Preservation Guidelines are met, and all Zoning setback requirements are met.
He went over the floor plan detailing the non-historic additions that are planned to be removed. He
showed a few pictures of the non-historic shed and trash enclosure that will also be removed.
Next, he went over in detail the conditions included in the resolution and the applicant’s responses to
each of the conditions. In this he detailed dividing the proposed lightwell on the Northwest corner of the
historic resource and he described the landscape plan.
He finished by stating they believe that they have met all the conditions of approval and that this would
be a benefit to the City and the community by supporting an eventual affordable housing application
and by the restoration of a historic Victorian in a highly visible location.
Ms. Thompson asked about the location of the proposed fence and if the intent was for it to be on the
property line, to which Mr. Clauson said yes, it would be on the property line.
Staff Presentation: Amy Simon - Planning Director
Ms. Simon started by reviewing the process that is in front of HPC. She went over the new section of
Growth Management Code that facilitated this review. For this project to come before HPC staff had to
make sure that the historic resource would be fully detached from any new construction, that all non-
historic additions on the resource would be removed and no new additions would be added to the
resource. The historic structure would also need a 10-foot buffer around it.
She said it was important to note that under the new Land Use Code HPC, in their review of the
relocation, may not deny the relocation, but shall determine the location of the historic resource that
best meets the City’s Historic Preservation Design Guidelines while accommodating the allowed
development rights of the property.
103
REGULAR MEETING HISTORIC PRESERVATION COMMISSION APRIL 26TH, 2023
She then went over the two review steps in the process. This hearing is the first step, and the second
step is an administrative review of another application that would go over transportation mitigation,
affordable housing credits, zoning requirements with no variance requests, and a limited design review
conducted by herself and Ms. Thompson.
She noted one of the successes of this project and why it was created is that it places the historic
resource as a free-standing building, prominently located at the corner of the site. The are few examples
in town where the preservation of a historic resource with no future additions has been secured.
Next, she went over the details of each condition included in the resolution. She said that staff supports
the project and find that the scope of work meets the guidelines and criteria in front of HPC.
Ms. Thompson asked why a full preservation plan was not required or included. Ms. Simon mentioned it
is usually something that HPC requires, and it could be added to the resolution.
Mr. Halferty asked about the guidelines related to the relocation that staff is looking at in their
recommendation. Ms. Simon detailed the criteria needed to be met, highlighting Criteria #4 and went
over staff’s reasoning.
PUBLIC COMMENT: Mr. David Scruggs asked if the basement was proposed to be expanded. Ms. Simon
said that the existing basement will be fully demolished and new basement, limited to the footprint of
the historic resource is proposed. Mr. Clauson said that the new basement would be structurally
necessary to be under the entire footprint but was not sure if that would be an expansion.
Mr. Scruggs said he asked the question because the new procedure does not allow any additions to be
added. He claimed that the new basement would expand the square footage and thus be an addition.
Next, he provided each of the HPC members a few handouts (added to packet as Exhibit C) that provide
an overview of his comments. He then spoke to the idea of balance. Balance between the preservation
of a historic resource and affordable housing. He said that he thought the reason for the relocation of
the historic resource was to build nine affordable housing units, consisting of 22 bedrooms and 7
parking spaces. He said he wanted any affordable housing to be livable and to respect the historic
resource. He did not think this project accomplishes those things. He asked that the proposed
movement of the historic resource to 10 feet from the property line be adjusted to 17 feet from the
property line. He also commented on other historic resources surrounding this project and their relative
setback distances. He expressed his concerns about the drainage on the site.
Ms. Marsha Dowler asked for the slide showing the site plan of the current location and proposed
relocation of the historic resource be displayed again. She then went on to comment that the historic is
being shoehorned with the relocation. She asked that this project be focused on protecting the historic
resource and the proposed relocation of the resource contradicts this. She also noted the traditional
setbacks that exist on neighboring historic properties.
Mr. Clauson responded to the public comments by addressing the proposed location and clarified
distances from the sidewalks and setbacks. He said that bringing the resource forward to the front
setback is in line with the concept of build to lines. He invited Mr. Brian Beasley from DJ architects to
address the comments regarding the proposed new basement. Mr. Beasley noted that the removal of
the non-historic additions would be about a wash with any additional square footage of the new
basement. Mr. Clauson said the clear intent was that there would not be a visible addition that affected
the historic resource.
104
REGULAR MEETING HISTORIC PRESERVATION COMMISSION APRIL 26TH, 2023
Mr. Fornell asked if there was additional City right of way space between the edge of the sidewalk and
the lot line. Mr. Clauson said yes.
Ms. Thompson asked Ms. Simon if in their review of the foundation that any below grade work must
conform with the code whether it expands the basement or not. Ms. Simon said there is a section of the
design guidelines that addresses additions, and it is very directed to above grade construction.
Ms. Johnson further clarified the design guideline regarding additions and noted the language talks
about additions and not additional square footage.
Mr. Fornell asked that if any additions, above or below grade are proposed in the future that are
conforming to setbacks that HPC would not see it. Ms. Simon stated that there will not be an
opportunity to make an addition to this structure in the future which is what facilitated this process.
Mr. Halferty asked about the additional floor area created in the basement and if it complies with the
new code changes in this application. Ms. Simon again stated that in the design guidelines it was never
the intent to consider a basement as an addition in this process. She further explained that if there was
some way to add loft space inside the existing structure it would not be considered an addition, even
though it is adding floor area.
Ms. Thompson invited Mr. Scruggs to provide additional comments. Mr. Scruggs read the section of the
new code related to this process, noting that all non-historic additions must be removed, and that no
new addition will be made to the historic resource. He again claimed that the additional basement space
is an addition.
Mr. Clauson responded saying that the foundation being proposed is not the historic resource. The
historic resource is what is visible above grade, and the resource is what HPC is charged with protecting.
BOARD DISCUSSION: Ms. Thompson started the board discussion by reviewing the items before the
Board. She went on to provide her thoughts. She wanted the requirement of a full preservation plan be
added to the resolution and she thought the front lightwell should not be on the same plane as the front
wall of the resource. She also thought that more information regarding floor area and the basement will
need to be addressed during the staff review to verify conformance with the Land Use Code. She
believed that this does meet their criteria for relocation because this is not the original location of the
resource, and she is ok with the relocation. She then clarified her thoughts regarding the lightwell
location.
Mr. Fornell noted that he was ok with the relocation and Ms. Thompson’s request that a full
preservation plan be included in the resolution.
Ms. Surfas commented that while the resource was moved to this lot and is not in its historic location, it
has been in the current location for approximately 70 years. She was not in support of the relocation.
She was ok with it moving, but thought it was going too far in both directions. She did think they should
have a full preservation plan.
Mr. Halferty said he was fully in favor of affordable housing. He said he understood the new code
provisions and that HPC needs to comply with what is in front of them. He understood the applicants’
and neighbors’ concerns and hoped that there was a happy medium to be reached. He referenced the
relocation guidelines and agreed with Ms. Surfas that they can approve the movement, but it depends
105
REGULAR MEETING HISTORIC PRESERVATION COMMISSION APRIL 26TH, 2023
on how far. He agreed that a preservation plan should be required and with Ms. Thompson’s thoughts
on the lightwell location. He also said that adding housing will always have an effect on open space and
transportation and parking and that there is some room for give and take on this. He also agreed with
Ms. Surfas again and thought there could be a compromise on the relocation.
Mr. Moyer started by reviewing some of the history of other projects, some that included the addition
of affordable housing. In this he described the Paepcke estate and 834 W. Hallam. He admitted that he
voted in favor of the affordable housing project at 834 W. Hallam but thought that once complete HPC
totally blew it with the Poppies project at that address. He went on to explain more of his thoughts on
that project and the loss, in his mind, of the historic resource there. He noted the dilemma between
historic preservation and affordable housing. He thought that the applicant and the City staff have
deceived and been disrespectful to this board. He was disappointed that a two-person administrative
review can take place here and said that he was very disappointed in the City government and staff. He
thought they might as well dissolve the HPC. He said they should vote no on this and throw it in
Council’s face. He wanted to know if employee housing is going to take precedence over historic
preservation.
Ms. Thompson responded to Mr. Moyer’s comments saying that she had participated in almost every
meeting related to this code adjustment and was the only HPC member present. City Council’s direction
to staff was to remove HPC’s purview on most of these items.
Mr. Anderson asked Chairperson Thompson to address some commissioner comments. He said he
respected the commissioner’s position on this but reminded them that they had a very robust and open
conversation with HPC about this exact process and why they were doing it. He said they would not
have gone to City Council without a recommendation from HPC about the process. He wanted to put on
the record that they had received support from HPC on this.
Mr. Moyer wanted to note that in those meetings he had commented that conceptually he liked the
idea and was mainly thinking of a situation regarding a historic piece of land and not a historic piece of
land with a historic house on it. He stated that Council needs to look at this as it is a very distressing
situation.
Mr. Fornell said he had paid very close attention to all the discussions preceding the new code adoption.
He reminded the members that they have, in the past, approved the relocation of a historic resource
from its original location to the setback lines in order to facilitate affordable housing, setting a
precedent here. He thought the applicant has an appropriate relocation plan that gives the historic
resource prominence next to the street but not in the setbacks and urged the board to approve the
relocation as proposed.
Ms. Thompson said she heard Mr. Moyer’s comments, but they cannot relitigate the code with this
application. She did think there was an opportunity to discuss it further with Council. She wanted to
confirm that Ms. Surfas and Mr. Halferty did not support the proposed relocation and wanted to
understand what they would be in support of.
Mr. Halferty said he hadn’t seen the streetscape or contextual information and just thought it was
pushed as a chess move to plan for the next move.
Mr. Moyer concurred with Mr. Halferty.
106
REGULAR MEETING HISTORIC PRESERVATION COMMISSION APRIL 26TH, 2023
Ms. Thompson said, knowing that three members agree that the relocation is too far forward, she
wanted to be able to provide the applicant with some specific information on what they would like to
see to move forward.
MOTION: Mr. Fornell moved to approve the resolution with the addition of the preservation plan to the
existing conditions. Ms. Thompson seconded with the addition of the movement of the lightwell. Roll
call vote: Mr. Fornell, yes; Mr. Moyer, no; Ms. Surfas, no; Mr. Halferty, no; Ms. Thompson, yes. 2-3 vote,
motion does not pass.
Ms. Johnson reminded the members that HPC cannot deny relocation but can determine an appropriate
setting for the historic structure that best meets the historic preservation guidelines.
Ms. Thompson said she had heard and could support Mr. Halferty’s request to see more context.
There was further discussion about the request of the applicant to restudy the siting of the relocation
and present it in relation to the context of Main St. Mr. Halferty agreed with the request for a restudy
and said the siting needs to be consistent with the Main St. district, not just this historic lot.
Ms. Surfas agreed with Mr. Halferty regarding the context of the district.
Ms. Johnson asked if the board was suggesting a motion for continuance.
Mr. Clauson said he was not clear what the point of a continuance was. He asked if the board was
planning on deliberating on the question of what they would accept. Ms. Johnson said she understood
that the board was requesting more information to better understand what the context is and maybe
some reconsideration based upon the comments that have been heard.
Ms. Thompson tried to clarify what she had heard from some of the members. She said they are looking
for contextual studies of the neighborhood and the Main St. historic district showing the relationships to
surrounding structures. She thought it was an appropriate ask for more context to be provided to help
make their decisions.
Mr. Clauson said they could provide more context. He also wanted to point out that zoning provides for
a 10-foot setback and any non-historic building on Main St. could be built at this 10-foot setback. He said
that if this historic resource were to be pushed back further for some reason it could find itself setback
further than the surrounding buildings and receding in prominence and character.
Mr. Fornell stated that the farther they push the resource back the less prominence it has.
Mr. Halferty motioned to continue this item to May 24th at 4:30pm to provide more contextual language
as far as the Main St. historic district that helps the board understand the relocation and addressing Ms.
Thompson’s concerns regarding the placement of the lightwell. Ms. Thompson seconded. Roll call vote:
Mr. Fornell, no; Mr. Moyer, no; Ms. Surfas, yes; Mr. Halferty, yes; Ms. Thompson, yes. 3-2 vote, motion
passes.
ADJOURN: Ms. Thompson motioned to adjourn the regular meeting. Mr. Moyer seconded. All in favor;
motion passes.
____________________
Mike Sear, Deputy City Clerk
107
Mike Sear
From: Amy Simon
Sent: Monday, June 12, 2023 1:42 PM
To: Kate Johnson; Mike Sear; Kirsten Armstrong; Barb Pitchford;
jeffreyhalfertydesign@gmail.com; jodi@surfasconsulting.com; Kara Thompson; Peter
Fornell; roger
Subject: 205 W. Main public comment: Juliet Shield -Taylor
From: Juliet Shield -Taylor Eieshield email.com>
Date: June 12, 2023 at 9:09:28 AM MDT
To: amy.simon@aspen.gov_
Subject: Conservation Housing Partners LLC review
Amy please distribute my email to the HPC Members. Thanks!
Members Historic Preservation Commission/Chair and Amy Simon
It is my understanding that the applicant's proposal will be a two step
review process.
The first step is a relocation determination by HPC regarding the historic
resource on this historic property. The applicant has proposed building
affordable housing consisting of 9 units, 22 bedrooms with 7 parking
places. Perhaps 35 to 45 occupants may reside there? I am concerned
about the mass, scale and density of the proposal and that it will
overwhelm the historic Victorian there. I do not oppose affordable
housing but this massive proposal lacks porosity. Six units with 7
parking places would be more reasonable and provide livable housing
for the occupants.
The applicant proposes shoving the Victorian on that property to the
Northeast corner with small setbacks of 10 feet in the front and 5 feet
on the S. First St side. I consider these setbacks to be inadequate and
different from neighboring historic resources. Three historic resources
are to the immediate left and right of 205 and they all three have front
setbacks of 15+ feet. These Victorians are 211, 135 and 125 Main. Every
Victorian I have seen in the neighborhood have front setbacks of 15+
feet. I believe the development pattern of the contiguous historic
resources and neighborhood should be respected. Also the S. First side
setback should be the same as other contiguous historic properties. The
historic structure at 135 Main St has a 20 foot side setback. My house,
200 W. Hopkins (directly behind 205) has a side setback of 10 feet.
I would request you consider a 16 foot front setback and a 10 foot side
setback for 205 Main to have uniform facades on Main and consistent
setbacks on S. First. I also believe generous yards will provide livable
outdoor space for the large number of occupants.
Also please require the applicant to fully develop a stormwater plan
early in the design phase and administrative review. My home is directly
across the alley from 205. A large volume of water collects at the
intersection of the alley and S. First and does not drain, and freezes in
winter. This hazardous condition will become worse with this
development if stormwater is not adequately addressed.
Summary:
I DO NOT oppose affordable housing on this site.
I DO REQUEST:
A REDUCTION in Scale and Mass
UNIFORM facades and setbacks of Front 16 feet and Side 10 feet
RESPECT the historic development pattern of the block and
neighborhood
Create LIVABLE affordable housing with porosity and outdoor space
ADDRESS the dangerous Stormwater situation
Thank You,
Juliet Shield -Taylor
200 W. Hopkins
Mike Sear
From: Amy Simon
Sent: Monday, June 12, 2023 1:43 PM
To: Kate Johnson; Mike Sear; Kirsten Armstrong; Barb Pitchford;
jeffreyhalfertydesign@gmail.com; jodi@surfasconsulting.com; Kara Thompson; Peter
Fornell; roger
Subject: 205 W. Main public comment: David Melton
From: David Melton <meltoncpa@yahoo.com>
Sent: Monday, June 12, 2023 7:13 AM
To: Amy Simon <amy.simon@aspen.gov>
Subject: My comments on 205 Main St. redevelopment plan for HPC members
Members Historic Preservation Commission/Chair and Amy Simon
Re: 205 Redevelopment plan
As a neighbor, I want to give input to this two step review process.
The first step is a relocation determination by HPC regarding the historic resource on this historic
property. The applicant has proposed building affordable housing consisting of 9 units, 22 bedrooms
with 7 parking places. Many people may reside there. I am concerned about the mass, scale and
density of the proposal and that it will overwhelm the historic Victorian. I do not oppose affordable
housing but I think this dense proposal lacks porosity. Six units with 7 parking places would be more
reasonable and provide livable housing for the occupants.
The applicant proposes jamming the Victorian to the Northeast corner with small setbacks of 10
feet in the front and 5 feet on the S.First side. I consider these setbacks to be inadequate and
different from neighboring historic resources. Three historic resources are to the immediate left and
right of 205 and they all three have front setbacks of 15+ feet. These Victorians are 211, 135 (my
property)and 125 Main.
I can stand on the front porch of my property, 135 Main, and my front porch face aligns with 211 Main
and 125 Main. 205 Main should NOT be placed 5 feet in front of these facades.
Every Victorian I have seen in the neighborhood has front setbacks of 15 + feet. I believe the
development pattern of the contiguous historic resources and the neighborhood should be respected.
Also the S. First side setback should be the same as other contiguous historic properties. My historic
structure at 135 Main has a 20 foot side setback. 200 W Hopkins, directly behind 205, has a 10 foot
side setback.
I would request you consider a 16 foot front setback and a 10 foot side setback for 205 Main to have
uniform facades on Main and consistent setbacks on S.First. Generous yards and outdoor space for
the many occupants and making a beautiful street scape are desired goals.
Also please require applicant to fully develop a stormwater plan early in the design phase and
administrative review. My home is directly across street from 205. A large volume of water collects at
the intersection of the alley and S.First on both sides and does not drain and freezes in winter. This
hazardous condition will become worse with this development if stormwater from the development is
not properly controlled.
I DO NOT oppose affordable housing on this site.
I DO think there should be a REDUCTION in Scale and Mass.
UNIFORM facades and setbacks of Front 16 feet and Side 10 feet should be maintained thereby
respecting the historic development pattern of the block and neighborhood.
My objective is for the applicant to develop LIVABLE affordable housing with porosity and
outdoor space. Finally, the dangerous standing water and frozen pools caused by lack of drainage of
stormwater need to be addressed.
Thank You
David Melton
135 W Main
Sent from Yahoo Mail for Wad
1
Mike Sear
From:Amy Simon
Sent:Tuesday, June 13, 2023 4:20 PM
To:Mike Sear; Kate Johnson; Kirsten Armstrong; Barb Pitchford;
jeffreyhalfertydesign@gmail.com; jodi@surfasconsulting.com; Kara Thompson; Peter
Fornell; roger
Subject:205 W. Main Public Comment
Hi all- here is public comment for tomorrow night’s meeting.
From: Elizabeth <elizabeth.milias@comcast.net>
Sent: Tuesday, June 13, 2023 2:45 PM
To: Public Comment <publiccomment@aspen.gov>
Subject: HPC - 205 W Main - June 14 2023
To the members of HPC
As you contemplate the application for 205 W. Main, I offer the following for your consideration.
Regarding SETBACKS: The proposal is effectively to shoehorn the Victorian into the NE corner of the lot at 1 st and Main.
Yes, in its history, the Victorian was moved to that location, but this is immaterial to the appropriateness of what is
proposed. Neighboring Vics at 211, 135 and 125 each have a 17’ setback, nearly twice what is proposed here.
Furthermore, 135 on the opposite corner of 1st and Main has a 10’ setback from 1st. The property at hand should have
the same, not the proposed 5’ setback. It’s incongruous and wholly inappropriate, indicating great disregard for the
historic resource.
Under the new land use code, HPC’s responsibilities have been unfortunately curtailed, but you still do speak for the
historic resource. (If not you, then who?)
It’s true, you cannot deny a relocation, but you can determine appropriate siting on the lot. No one is asking you to be
arbitrary, rather, your challenge is to balance the Historic Preservation Design Guidelines with what is permitted by the
development rights on the property. Balance. What is proposed reluctantly enables the troublesome historic asset to
remain on the property. Ironically, it’s proposed siting is on a very prominent downtown corner. If this is okay, why not
hidden in the back on the SW corner? The treatment proposed for this Vic is one of inconvenience and afterthought,
hardly in line with our community values.
Speaking of community values, the following are from the AACP related to historic preservation that apply specifically to
your decision at hand:
“Preserving the historic built environment is vital to our culture.” p. 54
“A responsibly restored historic structure or site honors the history and culture of our town.” p.54
And a guiding directive:
AACP II.2: “Preserve structures to the highest possible degree of historic integrity while minimizing adverse
impacts to the neighborhood.” p.56
Housing is a hot-button issue in the community. Much of the rhetoric these days sounds a lot like “more is more.” In its
rush to advance this housing project, the city is hand-in-hand with the developer-applicant (a rarity indeed) as they test
2
the new rules. The question before you is not about “housing,” however. Regardless of your feelings about housing,
whether you like it or hate it, that is not the issue. This is a precedent-setting decision before HPC and you are charged
with serving as the voice for the historic asset at 205 W. Main.
You are not “anti-housing” if you deny this proposal. You serve on HPC because you are “pro-historic preservation.”
Please give these points serious consideration.
Thank you.
Elizabeth Milias
'7kOM p�5o✓\
June 14,2023
To :Members Historic Preservation Commission
From: Neighbors of 205 W Main
Neighbors remain concerned about the project and oppose
the proposal for the following reasons.
1. Failure to Qualify for Approval.
Applicant fails to qualify for approval under 26.470.090.D.3.a
the new bifurcated expedited two step administrative
review .
26.470.090.D.3.a provides: "HPC may not deny Relocation,
but shall determine a siting for the historic structure that best
meets the City of Aspen Historic Preservation Design
Guidelines while accommodating the allowed development
rights for the property. A Conceptual site plan representing
the full project must be provided to assist in this review."
Applicant has FAILED to provide "A Conceptual site plan
representing the full project must be provided to assist in this
review." Neighbors contend that application fails as they
MUST provide a Conceptual site plan representing the full
project.
Additionally, 26.470.090.D.3.a provides:
"Review of one hundred (100) percent affordable housing
development on designated sites containing a historic
resource where the historic resource is fully detached from
all new construction, and all non -historic additions are to be
removed, and no new addition will be made to the historic
resource, .... "
Applicant's Update reveals that an addition is in fact being
added to the Historic resource in that the basement is being
expanded from the existing 806.62 square feet to 880.44.
(see applicant addendum table Existing vs Proposed Net
Livable). Applicant erroneously contends this addition is
nullified by the elimination of the non -historic additions . This
reasoning is flawed in that the removal of the non -historic
additions are REQUIRED in order to proceed under this
provision of the LUC.
2. Design guidelines not met. Requested conditions
of approval inconsistent with Code.
• Guideline 1.1: All projects shall respect the historic
development pattern or context of the block,
neighborhood or district.
1. Building footprint and location should reinforce the
traditional patterns of the neighborhood.
2. Allow for some porosity on a site. In a residential project,
setback to setback development is typically
uncharacteristic of the historic context. Do not design a
project which leaves no useful open space visible from
the street.
NOT MET
Neighbors would observe the 1.1 is not met. What is to be
determined by HPC is the desired setback to be determined
in relocation. Setbacks are measured from the property line
to the historic resource including historic porches. All of
applicant's data is flawed because they computed the
"setback from Main Street curbline" and are measured to
"building faces exclusive of front porches". Both of these
measurements are erroneous (exclude front porches) or
irrelevant (measure from curbline). Applicant failed to identify
in blue 3 historic resources in the 300 Block North Main, 3
historic resources in 200 Block North W. Hopkins, and 2
historic resources 100 Block North W. Hopkins. Applicant
failed to identify 8 historic resources in total.
Applicant's data ignores property lines, setbacks, existing
surveys and fails to identify 8 historic resources in the
immediate neighborhood. Applicant's information is flawed
and therefore unreliable and unusable.
The correct data based upon surveys or records in HPC
archived files reveals the following concerning front setbacks
of 3 historic resources contiguous to the subject 205 from
west to east on the southside of Main.
211 Main 16.33 foot front setback from property line
135 Main 15.47 foot front setback from property line
125 main 15.47 foot front setback from property line
( applicants footprint of the building and representation of
front porch are inaccurate)
In addition the 8 Historic resources applicant failed to
identify all appear to have front setbacks in excess of 16 feet
from their property line.
Also 135 Main has a side setback of 10 to 20 feet from the
property line depending on the building. Interestingly, during
the 1989 project review 135 Main represented the
following: "Design Strategy - Of prime importance is that the
existing house structure (now used as offices) be kept intact
along with its generous front and side yards. Consequently,
the proposed construction is placed to the rear of the site
and existing building." This design strategy remain important
and even more relevant today considering the newer
developments built to the 5 or 10 feet setback along Main
Street since 1989.
In summary the applicant's proposed 10 foot front setback
and 5 foot side setback does NOT reinforce the traditional
patterns and context of the neighborhood and are
inconsistent with adjacent structures. Neighbors ask the
HPC to determine that a 16 foot front set back on Main and
a 10 foot side setback on First is more appropriate to
reinforce traditional front and side setbacks ,uniform
facades, and be compatible with historical development
patterns. It is important to respect past HPC decisions to
maintain surrounding front yards on historic landmarks (135,
125, 211) and to not erode the pattern of front yards in this
historic corner of Main Street. Yes, the building is not in its
original location, but the current location on Main was
thoughtfully selected in relationship to the historic context of
Main Street with generous front yards for homes. Jamming
the building into the northeast corner of the lot does not
make it more prominent. Driving down Main Street, it is the
properties with front yards, rows of cottonwood, and low
fences that stand out as important and prominent.
• Guideline 9.2: Proposals to relocate a building will be
considered on a case -by -case basis....
2. In a district, where numerous adjacent historic structures
may exist, the way that buildings were placed on the
site historically, and the open yards visible from the
street are characteristics that
should be respected in new development.
3. Provide a figure ground study of the surrounding parcels
to demonstrate the effects of a building relocation....
NOT MET
A 16 foot front setback and 10 foot side setback are more
consistent with adjacent historic structures , and promote
open yards visible from the street. Applicant's suggested
setbacks (front 10 ft and side 5 ft) adversely impact
surrounding parcels. See discussion of Guideline 1.1 above.
Guideline 1.8- Consider storm water quality in the early
design process.AN D Condition of Approval 8.
Stormwater management cannot be fully detailed until
after the additional allowances on this site are verified,
however the site plan represents no visible stormwater
features on the subject site surrounding the resource,
which is a condition of approval. A fully developed
stormwater management plan shall be provided in the
application for Administrative Review.
NOT MET
Applicant states " a complete and fully developed storm
water plan will be provided with the building permit
application."
Neighbors pointed out to HPC in a previous filing that S.First
slopes to the alley from both Main and W Hopkins collecting
a large volume of water and flooding at the intersection of
the alley and S.First . This will be exacerbated by the
construction of 9 units 22 bedrooms and 7 parking places as
previously proposed. The are no drains on First. Flooding of
applicant's and surrounding properties could occur. Also
thick iced conditions in the alley and intersection last through
the entire winter creating an unsafe condition.
Applicant seeks approval of the Affordable Housing before
addressing drainage and Stormwater.
Applicant fails to "consider storm water in the early design
process" and rather proposes to address this issue at the
Building Permit Stage. Neighbors believe drainage and
stormwater should be addressed "early in the design
process" and that Applicant should be required to comply
with the Condition of Approval which states "a fully
developed stormwater management plan shall be provided
in the application for Administrative Review." To delay
submission until the "building permit application" is to violate
BOTH the Guideline 1.8 and the Condition of Approval 8.
Respectfully applicant should not be allowed to rewrite nor
create Conditions of Approval.
• Condition of approval Z The applicant has committed
to retain and repair all exterior materials based on field
inspection with historic preservation staff, and at the
same inspection must work with historic preservation
staff to identify and up to three restoration actions that
will be accomplished. An inspection of the interior of
the structure after finishes are removed will be required
to ensure accurate representation of the building's
history, and may also generate opportunities for
restoration (up to three total) that must be completed.
NOT MET
Applicant unilaterally proposes deletion of this condition
describing it as inappropriate. Neighbors inquire does
applicant determine appropriate conditions of approval?
Applicant cites as "commendable" removal of 4 removals of
non historic additions. Neighbors would point
out 26.470.090.D.3.a provides:
"... all non -historic additions are to be removed.....":
Therefore, removal is not voluntary but mandatory.
Applicant states they are providing an improved permanent
foundation. Neighbors submit they are requesting relocation
and therefore must build a new foundation. Also applicant
claims to be restoring street scape of S. First, but Neighbors
respond that they are required to eliminate head in parking on
First. Neighbors contend this condition of approval be retained.
Neighbors DO NOT oppose affordable housing at
205 Main. Neighbors objective is to:
1) Preserve the Historic property by achieving a
balance of density, mass, scale and porosity.
2) Create uniform facades and setbacks with the 3
contiguous historic properties.
3) Respect the Historic development pattern of the
Block, Main Street Historic District and surrounding
neighborhood.
4) Create Livable affordable housing on the site
To accomplish these objectives Neighbors request
that the relocation of the Historic Structure be at a
FRONT SETBACK OF 16 feet and a SIDE SETBACK
(S. First) of 10 feet .
Respectfully submitted on behalf of Neighbors- David Scruggs
212 W. Hopkins