HomeMy WebLinkAboutFile Documents.1485 Homestake Dr.0091.2019 (14).ARBK Justin Hahn From: Justin Hahn Sent: Thursday, September 26, 2019 3:05 PM To: stulusk@gmail.com Cc: John Barker; Denis Murray(denism@ci.aspen.co.us) Subject: Round 2 Comments for 1485 Homestake - 0091.2019.ARBK Attachments: CCC First Review 1485 Homstake 0091.2019.ABRK Revised (1).pdf; Building Comments (1).pdf; Sample Air Sealing Details (blue).pdf Stuart, I've reviewed your responses to the comments from Colorado Cod Consulting and there are still some unresolved issues. Please see the below list of outstanding comments. You may respond to me directly when all comments have been addressed. Please include written response indicating how/where corrections have been made. I've also attached a copy of the original comment letter from CCC as well as your response letter for your reference. 1.VComments B-1ci and S-1 through S-8: No stamped structural plans were provided with your responses. Your unstamped structural proposed drawings do not resolve any of the original comments, without a stamp we cannot accept them as official construction documents. We acknowledge that your engineer is waiting until demolition begins in order to finish the actual structural plans and details, but you will need to acknowledge that we will not provide any inspections for this project until these stamped structural plans have been submitted, reviewed, and approved. These structural designs need to be a priority for you as soon as work begins. 2.`/Comment B-1ciii: No response was given,the original comment requesting flashing details at ledger connection to existing building still remains. 3.1/Comment B-4: No window/door flashing details were actually provided as your response indicated, all that was provided was references to "window/door flashing per IRC 703.4". IRC 703.4 requires flashing to be done in accordance with either the manufacturer's flashing details or the design professional's detailing. Provide or the other. Referencing the code section that requires the flashing detailing does not resolve the comment. 4.1/Comment B-5: No documentation of class A roof covering was provided. Referencing the code requirement on the plan does not satisfy the requirement, nor does stating that you will match existing class A roof construction. Original comment requesting the listing for the class A roof assembly still stands. If you can tell me the specific make or brand of treated shake you are proposing to use I may be able to help find the proper documentation. 5,4/Comment EN-4: Simply stating that air sealing requirements apply does not satisfy the comment, you need to show how you intend to meet the requirements. I've attached our standard air sealing details to this email that cover the 4 main methods of air sealing. If you identify which method, or combination of methods you intend to utilize I can attach the applicable sheets to your plan sets. We now require inspection of these air sealing components, so you may want to discuss this with your contractor before selecting the details you will be inspected to. The intent here is to attach the applicable detail sheet so that there is no confusion regarding what is expected for inspection purposes. Feel free to reach out to me directly if you have any questions or want to discuss anything prior to sending your responses. Justin Hahn ASPEN 1 Community Development Plans Examiner Salesforce—New Permitting System 130 S Galena St. Aspen, CO 81611 p 970.429.2784 c 970.319.1610 www.cityofaspen.com www.aspencommunityvoice.com Qd Notice and Disclaimer: This message is intended only for the individual or entity to which it is addressed and may contain information that is confidential and exempt from disclosure pursuant to applicable law. If you are not the intended recipient, please reply to the sender that you have received the message in error and then delete it. Further,the information or opinions contained in this email are based on current zoning and/or applicable building code regulations,are advisory in nature only and are not binding on the City of Aspen. If applicable,the information and opinions contained in the email are based on current zoning,which is subject to change in the future,and upon factual representations that may or may not be accurate. The opinions and information contained herein do not create a legal or vested right or any claim of detrimental reliance. 2