Loading...
HomeMy WebLinkAboutagenda.council.regular.20230725AGENDA CITY COUNCIL REGULAR MEETING July 25, 2023 5:00 PM, City Council Chambers 427 Rio Grande Place, Aspen I.Call to Order II.Roll Call III.Scheduled Public Appearances IV.Citizens Comments & Petitions V.Special Orders of the Day ZOOM Join from a PC, Mac, iPad, iPhone or Android device: Please click this URL to join. https://us06web.zoom.us/j/84512307527? pwd=NklvVTlYVTRMWVJxM0psd01WQ1ljUT09 Passcode: 81611 Or join by phone: Dial(for higher quality, dial a number based on your current location): US: +1 719 359 4580 Webinar ID: 845 1230 7527 Passcode: 81611 International numbers available: https://us06web.zoom.us/u/kdPC4YtnRD (Time for any citizen to address Council on issues NOT scheduled for a public hearing. Please limit your comments to 3 minutes) a) Councilmembers' and Mayor's Comments b) Agenda Amendments c) City Manager's Comments d) Board Reports 1 1 VI.Consent Calendar VI.A Resolution #102, Series of 2023 - Residential Contracts to Purchase and Sell City Owned Real Property to City Employees Subject to Certain Occupancy and Resale Deed Restriction, Agreement and Covenants VI.B Resolution #109, Series of 2023 - Contract for Wheeler grandMA Lighting Console VI.C Resolution #110, Series of 2023 - Authorizing the City Manager to Designate a Signatory for Tenant Leases and/or Agreements not to exceed a Twelve Month Term VI.D Draft Minutes of June 6th, 2023 VII.Notice of Call-Up VIII.First Reading of Ordinances VIII.AOrdinance #13, Series of 2023 - 104 and 108 Midland Avenue, Minor Planned Development Amendment, Project Review. IX.Public Hearings X.Action Items X.A Resolution #111, Series of 2023 - Establish the Newspaper for Legal Advertising/Notices for the City of Aspen XI.Adjournment (These matters may be adopted together by a single motion) Real_Estate_Contract_-_City_Council_memorandum.docx Resolution__102__2023__real_estate_-_employee_housing.TNedits.7132023.docx Council Memo For Resolution #109, series 2023 - Contract for Wheeler grandMA Lighting Console Resolution #109, series 2023 - Contract for Wheeler grandMA Lighting Console Exhibit A - 2023-226 grandMA Lighting Console BARBIZON Supply Procurement Agreement Tenant leases .docx Resolution_110_lease_authority (Final).docx cc.min.060623.docx 104_108 Midland Avenue_First Reading_Memo_CC.pdf Ordinance 13_First Reading_104_108 Midland Avenue.docx Exhibit A_Review Criteria_Staff Findings.pdf Exhibit B_Application_104_108 Midland Ave PD Amendment.pdf Legal_Advertising_Memo_2023_final SGO.docx Legal_Advertising_Resolution__111_.docx Professional_Services_Agreement_-_Legal_Advertising_RFP.docx.pdf 2 2 Page 1 of 2 MEMORANDUM TO: Mayor and City Council FROM: Tara L. Nelson, Senior Paralegal THRU: James R. True, City Attorney DATE OF MEMO:July 13, 2023 MEETING DATE:July 25, 2023 RE:Resolution #102, Series of 2023 REQUEST OF COUNCIL: This is a one-time request to authorize the City Manager or her written designee to execute certain real estate contract purchases and/or sales for city owned real properties dedicated as employee housing units that may come up from time to time. PREVIOUS COUNCIL ACTION:Resolution #12, Series of 1998 was previously authorized for the sale of certain real properties situate in the Aspen Water Plant and Affordable Housing Subdivision in the City of Aspen. Council has not been previously requested to execute a resolution for each real estate sales transaction to each city employee, as that has been deemed within the authority of the City Manager under the Charter, ordinances and previous authority granted by Council. DISCUSSION:The City of Aspen has an inventory of employee housing units that become available from time to time for qualified employees to purchase. We have traditionally utilized a title company that did not require a recorded Resolution authorizing the real estate purchases and/or sales transaction(s), but currently, Title Company of the Rockies, is requesting a recorded Resolution to use for all current and future purchases and sales for their files. FINANCIAL/BUDGET IMPACTS:Not applicable. Revenues received from specific real estate transaction(s)and sale(s)of employee housing unit(s)to city employee(s)are identified in the Employee Housing Fund and can be determined by contacting the Finance department. ENVIRONMENTAL IMPACTS: Not Applicable. RECOMMENDED ACTION:Approval of Resolution #102, Series of 2023 ALTERNATIVES: If Council does not want to approve the staff recommendation, they could choose to procure a different title company that does not have the requirement of a recorded resolution for real estate transactions. PROPOSED MOTION:I move to approve Resolution #102, Series of 2023. 3 Page 2 of 2 CITY MANAGER COMMENTS: ATTACHMENTS: 4 RESOLUTION #102 (Series of 2023) A RESOLUTION OF THE CITY COUNCIL OF THE CITY OF ASPEN, COLORADO, APPROVING RESIDENTIAL CONTRACTS TO PURCHASE AND SELL CITY OWNED REAL PROPERTY TO CITY EMPLOYEES SUBJECT TO CERTAIN OCCUPANCY AND RESALE DEED RESTRICTIONS FOR SAID PROPERTIES, AND AUTHORIZING THE CITY MANAGER OR WRITTEN DESIGNEE TO EXECUTE SAID AGREEMENTS AND DOCUMENTS ON BEHALF OF THE CITY OF ASPEN, COLORADO. WHEREAS, the City of Aspen owns certain real properties within and without its corporate limits; and WHEREAS, Section 1.4 of the Home Rule Charter for the City of Aspen, Colorado authorizes the City of Aspen to sell, lease, mortgage, hold, manage, and control such property as its interests may require; and WHEREAS, the City of Aspen, in furtherance of its policy of assisting its employees in securing affordable housing, has indicated its willingness to have real properties purchased by existing City employees subject to certain conditions and restrictions; and WHEREAS, the buyers of said properties are employees of the City of Aspen and have indicated a desire to purchase said properties from the City; and WHEREAS, the property will continue to be part of the City of Aspen internal housing program to assist in critical recruitment and retention of an exceptional workforce; and WHEREAS, the sale and purchase of said units shall be subject to certain occupancy and resale deed restrictions, and WHEREAS, the City Council finds and determines that it is in the best interest of the City of Aspen to approve this Resolution and sell certain real property as set forth in the Real Estate Contract(s) and City of Aspen Occupancy and Resale Deed Restriction, Agreement and Covenant(s) from time to time; and NOW, THEREFORE, BE IT RESOLVED BY THE COUNCIL OF THE CITY OF ASPEN, COLORADO: 1. Recitals: The foregoing recitals are incorporated herein as findings of the Aspen City Council. 2. Real Estate Contract(s) and Resale Deed Restriction, Agreement and Covenant(s): The Aspen City Council hereby approves the certain Real Estate Contract(s) and City of Aspen Occupancy and Resale Deed Restriction, Agreement and Covenant(s) that may be presented from this day forward and authorizes the City Manager or her written designee to execute said agreements and take all actions pursuant to same to effectuate the sale of the real property, including any documents required by a title company, and to take other required actions related to the sale of the real property, following consultation with the City Attorney. The Aspen City Council further authorizes the City Manager or 5 Page | 2 her written designee, upon consultation with and recommendation of the City Attorney, to make any amendments to the Real Estate Contract(s) and/or the Resale Deed Restriction, Agreement and Covenant(s) that are reasonably necessary for the purchase and/or sale of the Property or to terminate the contract(s), without further approval of the Aspen City Council. 3. Ratification of Actions. All actions heretofore taken, not inconsistent with the provisions of this Resolution, by the Aspen City Council and the officers, agents, and employees of the City of Aspen relating to the subject matter of this Resolution, are hereby ratified, approved and confirmed. 4. Severability. If any provision of the Resolution is found to be unconstitutional or unlawful, such finding shall only invalidate that part or portion found to violate the law. All other provisions shall be deemed severable and shall continue in full force and effect. INTRODUCED, READ AND ADOPTED by the City Council of the City of Aspen on the ________day ________________of 2023. CITY OF ASPEN, COLORADO _________________________________ Torre, Mayor ATTEST: I, Nicole Henning, duly appointed and acting City Clerk do certify that the foregoing is a true and accurate copy of that resolution adopted by the City Council of the City of Aspen, Colorado, at a meeting held on the day herein above stated. ________________________________ Nicole Henning, City Clerk 6 MEMORANDUM TO: Mayor and City Council FROM: Lisa Rigsby Peterson, Executive Director of the Wheeler Opera House Craig Moxon, Production Manager, Wheeler Opera House THROUGH:Alixandra Feeley, Business Manager, Wheeler Opera House MEMO DATE:July12th, 2023 MEETING DATE:July 25th, 2023 RE:Resolution #109 Series 2023: Contract for Wheeler grandMA Lighting Console REQUEST OF COUNCIL:Approval of the contract between the City of Aspen and Barbizon Light of the Rockies, Inc. for purchase and delivery of one (1) grandMA3 Full- Size lighting console, the hardware used in theatrical lighting design to control multiple instruments at once. This contract is for $70,750.00. SUMMARY AND BACKGROUND: This equipment purchase project funds the acquisition of a concert industry standard lighting console. The grandMA3 Full-Size offers the ultimate in lighting control hardware: powerful functionality and hands-on flexibility through improved functionality and a fresh intuitive interface. It includes extensive control parameters, physical playbacks, and additional assignable x-keys for even more flexibility – at the Wheeler Opera House, this translates to greater control and expanded lighting design and artistic capacity for our performers and staff to the delight of our audiences. DISCUSSION:Modern stage lighting systems consist of fixtures, dimming & distribution, cabling, and consoles: this purchase project upgrades the existing lighting console. Our current lighting system is reliant on a single, eight-year-old, midrange console and lacks adequate back up if any issues were to arise. With the addition of a new, sophisticated lighting console, our lighting system gains adequate backup as well as the ability to meet the technical and artistic needs of more performers. Proposals were evaluated and reviewed on the following criteria: the ability to provide the required equipment, timeline for delivery, experience, previous projects, as well as project costs and warranty. Criteria were individually weighted resulting in a final cumulative score. The ITP committee (comprised of Wheeler Staff) unanimously recommended that Barbizon be awarded the contract. The primary factor in evaluating qualifications was overall cost. From the bids received, Barbizon had the best pricing and offered a clearly defined timeline for delivery. 7 Barbizon is a leading supplier of high-quality lighting systems across event production venues, including festival spaces, conference halls, houses of worship, and theatres. Overall, our review committee awarded a top score to Barbizon Light of the Rockies, Inc. FINANCIAL IMPACTS: This project is coming in below budget; staff feel that the pricing is at fair market value, based on competitive quotes received. This theatrical production improvement project is funded by the Arts & Culture fund as a Wheeler Opera House Capital Project. The project is funded in 2023. The project was budgeted for $90,000 and the selected vendor bid is $70,750.00. No additional funds are needed for this purchase. ENVIRONMENTAL IMPACTS: ALTERNATIVES: RECOMMENDATIONS:Staff recommends approval of Resolution #109, series 2023: Contract 2023-226 for Wheeler grandMA Lighting Console. CITY MANAGER COMMENTS: 8 RESOLUTION #109 (Series of 2023) A RESOLUTION OF THE CITY COUNCIL OF THE CITY OF ASPEN, COLORADO, APPROVING A CONTRACT BETWEEN THE CITY OF ASPEN AND BARBIZON LIGHT OF THE ROCKIES, INC. AUTHORIZING THE CITY MANAGER TO EXECUTE SAID CONTRACT ON BEHALF OF THE CITY OF ASPEN, COLORADO. WHEREAS, there has been submitted to the City Council a contract for, the for purchase and delivery of a grandMA Lighting Console, the hardware used in theatrical lighting design to control multiple instruments at once, between the City of Aspen and Barbizon Light of the Rockies, Inc., a true and accurate copy of which is attached hereto as Exhibit “A”; NOW, THEREFORE, BE IT RESOLVED BY THE CITY COUNCIL OF THE CITY OF ASPEN, COLORADO, That the City Council of the City of Aspen hereby approves that Contract for, the purchase and delivery of a grandMA Lighting Console between the City of Aspen and Barbizon Light of the Rockies, Inc. a copy of which is annexed hereto and incorporated herein, and does hereby authorize the City Manager to execute said agreement on behalf of the City of Aspen. INTRODUCED, READ AND ADOPTED by the City Council of the City of Aspen on the 25 th day of July 2023. Torre, Mayor I, Nicole Henning, duly appointed and acting City Clerk do certify that the foregoing is a true and accurate copy of that resolution adopted by the City Council of the City of Aspen, Colorado, at a meeting held, July 25 th, 2023. Nicole Henning, City Clerk 9 CITY OF ASPEN STANDARD FORM OF AGREEMENT SUPPLY PROCUREMENT City of Aspen Project No.: 2023-226 AGREEMENT made as of 10th day of July, in the year 2022. BETWEEN the City: Contract Amount: And the Vendor: Summary Description of Items to be Purchased: Exhibits appended and made a part of this Agreement: If this Agreement requires the City to pay an amount of money in excess of $50,000.00 it shall not be deemed valid until it has been approved by the City Council of the City of Aspen. City Council Approval: Date: 7/25/2023 Resolution No.: #109 The City of Aspen c/o Wheeler Opera House 427 Rio Grande Place Aspen, Colorado 81611 Phone: (970) 920-5055 Total: $70,750.00 Barbizon Light of the Rockies 8269 East 23rd Avenue Suite 111 Denver, CO 80238 (303) 394-9875 pmaurelli@barbizon.com One (1) grandMA3 Full Size lighting console and flight case. Exhibit A: Bid Proposal including Items to be Purchased and Fee DocuSign Envelope ID: A22C5AD8-5308-42E6-B27C-276BF608F383 10318 The City and Vendor agree as set forth below. 1. Purchase. Vendor agrees to sell and City agrees to purchase the items on Exhibit A appended hereto and by this reference incorporated herein as if fully set forth here for the sum set forth hereinabove. 2. Delivery. (FOB 320 E Hyman Ave, Aspen, CO, 81611) [Delivery Address] 3. Contract Documents. This Agreement shall include all Contract Documents as the same are listed in the Invitation to Bid and said Contract Document are hereby made a part of this Agreement as if fully set out at length herein. 4. Warranties. 5. Successors and Assigns. This Agreement and all of the covenants hereof shall inure to the benefit of and be binding upon the City and the Vendor respectively and their agents, representatives, employee, successors, assigns and legal representatives. Neither the City nor the Vendor shall have the right to assign, transfer or sublet its interest or obligations hereunder without the written consent of the other party. 6. Third Parties. This Agreement does not and shall not be deemed or construed to confer upon or grant to any third party or parties, except to parties to whom Vendor or City may assign this Agreement in accordance with the specific written permission, any right to claim damages or to bring any suit, action or other proceeding against either the City or Vendor because of any breach hereof or because of any of the terms, covenants, agreements or conditions herein contained. 7. Waivers. No waiver of default by either party of any of the terms, covenants or conditions hereof to be performed, kept and observed by the other party shall be construed, or operate as, a waiver of any subsequent default of any of the terms, covenants or conditions herein contained, to be performed, kept and observed by the other party. 8. Agreement Made in Colorado. The parties agree that this Agreement was made in accordance with the laws of the State of Colorado and shall be so construed. Venue is agreed to be exclusively in the courts of Pitkin County, Colorado. 9. Attorney’s Fees. In the event that legal action is necessary to enforce any of the provisions of this Agreement, the prevailing party shall be entitled to its costs and reasonable attorney’s fees. 10. Waiver of Presumption. This Agreement was negotiated and reviewed through the mutual efforts of the parties hereto and the parties agree that no construction shall be made or presumption shall arise for or against either party based on any alleged unequal status of the parties in the negotiation, review or drafting of the Agreement. DocuSign Envelope ID: A22C5AD8-5308-42E6-B27C-276BF608F383 11319 11. Certification Regarding Debarment, Suspension, Ineligibility, and Voluntary Exclusion. Vendor certifies, by acceptance of this Agreement, that neither it nor its principals is presently debarred, suspended, proposed for debarment, declared ineligible or voluntarily excluded from participation in any transaction with a Federal or State department or agency. It further certifies that prior to submitting its Bid that it did include this clause without modification in all lower tier transactions, solicitations, proposals, contracts and subcontracts. In the event that Vendor or any lower tier participant was unable to certify to the statement, an explanation was attached to the Bid and was determined by the City to be satisfactory to the City. 12. Warranties Against Contingent Fees, Gratuities, Kickbacks and Conflicts of Interest. (A) Vendor warrants that no person or selling agency has been employed or retained to solicit or secure this Contract upon an agreement or understanding for a commission, percentage, brokerage, or contingent fee, excepting bona fide employees or bon a fide established commercial or selling agencies maintained by the Vendor for the purpose of securing business. (B) Vendor agrees not to give any employee of the City a gratuity or any offer of employment in connection with any decision, approval, disapproval, recommendation, preparation of any part of a program requirement or a purchase request, influencing the content of any specification or procurement standard, rendering advice, investigation, auditing, or in any other advisory capacity in any proceeding or application, request for ruling, determination, claim or controversy, or other particular matter, pertaining to this Agreement, or to any solicitation or proposal therefore. (C) Vendor represents that no official, officer, employee or representative of the City during the term of this Agreement has or one (1) year thereafter shall have any interest, direct or indirect, in this Agreement or the proceeds thereof, except those that may have been disclosed at the time City Council approved the execution of this Agreement. (D) In addition to other remedies it may have for breach of the prohibitions against contingent fees, gratuities, kickbacks and conflict of interest, the City shall have the right to: 1. Cancel this Purchase Agreement without any liability by the City; 2. Debar or suspend the offending parties from being a vendor, contractor or subcontractor under City contracts; 3. Deduct from the contract price or consideration, or otherwise recover, the value of anything transferred or received by the Vendor; and 4. Recover such value from the offending parties. 13. Termination for Default or for Convenience of City. The sale contemplated by this Agreement may be canceled by the City prior to acceptance by the City whenever for any reason and in its sole discretion the City shall determine that such cancellation is in its best interests and convenience. DocuSign Envelope ID: A22C5AD8-5308-42E6-B27C-276BF608F383 12320 14. Fund Availability. Financial obligations of the City payable after the current fiscal year are contingent upon funds for that purpose being appropriated, budgeted and otherwise made available. If this Agreement contemplates the City using state or federal funds to meet its obligations herein, this Agreement shall be contingent upon the availability of those funds for payment pursuant to the terms of this Agreement. 15. City Council Approval. If this Agreement requires the City to pay an amount of money in excess of $50,000.00 it shall not be deemed valid until it has been approved by the City Council of the City of Aspen. 16. Non-Discrimination. No discrimination because of race, color, creed, sex, marital status, affectional or sexual orientation, family responsibility, national origin, ancestry, handicap, or religion shall be made in the employment of persons to perform under this Agreement. Vendor agrees to meet all of the requirements of City’s municipal code, section 13-98, pertaining to nondiscrimination in employment. Vendor further agrees to comply with the letter and the spirit of the Colorado Antidiscrimination Act of 1957, as amended and other applicable state and federal laws respecting discrimination and unfair employment practices. 17. Integration and Modification. This written Agreement along with all Contract Documents shall constitute the contract between the parties and supersedes or incorporates any prior written and oral agreements of the parties. In addition, vendor understands that no City official or employee, other than the Mayor and City Council acting as a body at a council meeting, has authority to enter into an Agreement or to modify the terms of the Agreement on behalf of the City. Any such Agreement or modification to this Agreement must be in writing and be executed by the parties hereto. 18. Authorized Representative. The undersigned representative of Vendor, as an inducement to the City to execute this Agreement, represents that he/she is an authorized representative of Vendor for the purposes of executing this Agreement and that he/she has full and complete authority to enter into this Agreement for the terms and conditions specified herein. 19. Electronic Signatures and Electronic Records This Agreement and any amendments hereto may be executed in several counterparts, each of which shall be deemed an original, and all of which together shall constitute one agreement binding on the Parties, notwithstanding the possible event that all Parties may not have signed the same counterpart. Furthermore, each Party consents to the use of electronic signatures by either Party. The Scope of Work, and any other documents requiring a signature hereunder, may be signed electronically in the manner agreed to by the Parties. The Parties agree not to deny the legal effect or enforceability of the Agreement solely because it is in electronic form or because an electronic record was used in its formation. The Parties agree not to object to the admissibility of the Agreement in the form of an electronic record, or a paper copy of an electronic documents, or a paper copy of a document bearing an electronic signature, on the ground that it is an electronic record or electronic signature or that it is not in its original form or is not an original. DocuSign Envelope ID: A22C5AD8-5308-42E6-B27C-276BF608F383 13321 IN WITNESS WHEREOF, The City and the Vendor, respectively have caused this Agreement to be duly executed the day and year first herein, of which, to all intents and purposes, shall be considered as the original. FOR THE CITY OF ASPEN: By: Aspen City Manager Date SUPPLIER: By: Title Date Approved as to form: City Attorney’s Office DocuSign Envelope ID: A22C5AD8-5308-42E6-B27C-276BF608F383 Systems Integrator 7/11/2023 | 8:33:08 PM MDT Peter Maurelli 14322 EXHIBIT A: BID PROPOSAL DocuSign Envelope ID: A22C5AD8-5308-42E6-B27C-276BF608F383 15323 DocuSign Envelope ID: A22C5AD8-5308-42E6-B27C-276BF608F383 16324 Page 1 of 1 MEMORANDUM TO: Mayor and City Council FROM: Tara L. Nelson, Senior Paralegal THRU: James R. True, City Attorney DATE OF MEMO:July 13, 2023 MEETING DATE:July 25, 2023 RE:Resolution #110, Series of 2023 REQUEST OF COUNCIL: This is a one-time request to authorize the City Manager or her written designee or the Acting City Manager to execute certain tenant leases and/or agreements that do not exceed one (1) year, that may come up from time to time. PREVIOUS COUNCIL ACTION:No previous City Council action has been formally taken. DISCUSSION:The City of Aspen has an inventory of various tenant leases that come up for renewal and authorization from time to time.For example, the Red Brick Center for the Arts has a dance studio, various artist studios, and not-for-profit office space that local business and artists rent. For those leases that do not exceed a one (1) year occupancy, this housekeeping measure allows the City Manager to designate a signatory for those particular short-term tenants. This Resolution applies to any City of Aspen owned real property of which a tenant may enter into a lease and/or agreement. FINANCIAL/BUDGET IMPACTS:Not applicable. ENVIRONMENTAL IMPACTS: Not Applicable. RECOMMENDED ACTION:Approval of Resolution #110, Series of 2023 ALTERNATIVES:City Council could choose not to allow the City Manager to designate a signatory for shorter termed leases and/or agreements. PROPOSED MOTION:I move to approve Resolution #110, Series of 2023. CITY MANAGER COMMENTS: ATTACHMENTS: 17 RESOLUTION #110 (Series of 2023) A RESOLUTION OF THE CITY COUNCIL OF THE CITY OF ASPEN, COLORADO, AUTHORIZING CITY MANAGER OR HER WRITTEN DESIGNEE, OR THE ACTING CITY MANAGER TO EXECUTE TENANT LEASES AND/OR AGREEMENTS WHICH DO NOT EXCEED THE DURATION OF TWELVE MONTHS ON BEHALF OF THE CITY OF ASPEN, COLORADO. WHEREAS, the City of Aspen owns certain real properties within and without its corporate limits; and WHEREAS, Section 1.4 of the Home Rule Charter for the City of Aspen, Colorado authorizes the City of Aspen to sell, lease, mortgage, hold, manage, and control such property as its interests may require; and WHEREAS, for example the City of Aspen enters into employee housing tenant leases that do not exceed twelve (12) months, as are deemed transitional and/or temporary, within said real properties from time to time; and WHEREAS, the City of Aspen has the authority to approve and execute all contracts wherein the City is a contracting party; and WHEREAS, pursuant to Section 6.3 of the Home Rule Charter for the City of Aspen, Colorado, the City of Aspen City Manager has certain powers and duties, including the authority to sign leases and agreements and further to delegate that authority with specific instructions; and NOW, THEREFORE, BE IT RESOLVED BY THE COUNCIL OF THE CITY OF ASPEN, COLORADO: 1. Recitals: The foregoing recitals are incorporated herein as findings of the Aspen City Council. 2. Tenant Lease(s) and agreements that do not exceed twelve (12) months: The Aspen City Council hereby authorizes the City Manager or her written designee, or the acting City Manager, to execute said tenant leases and/or agreements and take all actions to effectuate said leases and/or agreements. The Aspen City Council further authorizes the City Manager or her written designee, or the acting City Manager, upon consultation with and recommendation of the City Attorney, to make any amendments to said tenant leases and agreements that are reasonably necessary, without further approval of the Aspen City Council. 3. Ratification of Actions. All actions heretofore taken, not inconsistent with the provisions of this Resolution, by the Aspen City Council, the City Manager and the officers, agents, and employees of the City of Aspen relating to the subject matter of this Resolution, are hereby ratified, approved and confirmed. 18 Page | 2 4. Severability. If any provision of the Resolution is found to be unconstitutional or unlawful, such finding shall only invalidate that part or portion found to violate the law. All other provisions shall be deemed severable and shall continue in full force and effect. INTRODUCED, READ AND ADOPTED by the City Council of the City of Aspen on the ________day ________________of 2023. CITY OF ASPEN, COLORADO _________________________________ Torre, Mayor ATTEST: I, Nicole Henning, duly appointed and acting City Clerk do certify that the foregoing is a true and accurate copy of that resolution adopted by the City Council of the City of Aspen, Colorado, at a meeting held on the day herein above stated. ________________________________ Nicole Henning, City Clerk 19 1 REGULAR MEETING ASPEN CITY COUNCIL JUNE 6TH, 2023 At 5:00 p.m. Mayor Torre called the regular meeting to order with Councilors Hauenstein, Doyle, Rose and Guth present. SCHEDULED PUBLIC APPEARANCES: Mayor Torre announced the Historic Preservation team in the room for the 30th Historic Preservation Awards with chairman Jeffrey Halferty, Amy Simon and Kirsten Armstrong who joined the city last month as the new HPC liaison. Mr. Halferty introduced the HPC award for a cultural center, the Wheeler Opera House at 320 East Hyman Avenue. He described the history of the building over the years and the recent historic work that was performed. Kara Thompson, co-chair entered the meeting. Together, they presented the awards to Lisa Rigsby Peterson, Summit Sealants, Concept 1 Group, Forrest Painting, Built Environment Evolution, Bendon Adams, and others. CITIZEN COMMENTS: Ed Cross – Mr. Cross of the HOA board for Centennial. read another poem for Centennial in hopes of working things out. Mayor Torre wrote a responsive poem for Ed Cross and Centennial which he read. Toni Kronberg – Ms. Kronberg referenced a memo on the Lumberyard and protecting the environment. She mentioned the environmental part wasn’t in the whereas. She brought up the entrance to Aspen. She hasn’t let up on her efforts to keep transportation moving through Aspen and she brought up her gondola sky cab idea. She’s going to start a petition to bring forth to all elected officials to take it to the ballot. Councilor Hauenstein mentioned that this came before the EOTC, and it was turned down. Barb Frank – Ms. Frank said she lives in Centennial and it’s hard for her to rationalize the Lumberyard and expense when we have a community that is failing and needs a reboot. Mike Triplett – Mr. Triplett said he started a group called the West End Pedestrian Safety Group a couple of years ago. He’s asking for them to adopt a draft resolution that they put in front of council last week. COUNCIL COMMENTS: Councilor Rose read a paragraph from Lo Semple’s column this week. There is a lot of negativity in this town and he loves that Lo wrote something positive. He’s been reading emails about the west end issues and is interested in a work session for this issue. Councilor Guth said he would like to see continued progress for virtual attendance at P&Z and HPC. He requests an update from staff on filling city owned housing units. He’d like to see action taken on the west end issues. He heard from Bosq about using heaters on their deck. He doesn’t support this and doesn’t have an issue with gas heaters. Councilor Hauenstein mentioned the Memorial Day ceremony at Veterans Park followed by the Elks lunch and said it was appreciated by all. He spoke about a psychedelic symposium at the Wheeler Opera House regarding rules, protocols, etc. for medicinal use. He attended and it was mostly a good use of 20 2 REGULAR MEETING ASPEN CITY COUNCIL JUNE 6TH, 2023 time. The Wheeler Opera House is beautiful and such a gem to our community. It’s amazing what the Wheeler RETT has done. Mayor Torre spoke about Food and Wine coming up next weekend. It’s the 40 th anniversary. Here we go; get ready. We have received a bunch of emails from the west end group recently. He would love for new council members to have the information which we have already spoken about in the past so we can decide something moving forward. Ms. Ott said you have a work session coming up in two weeks to expand the conversation. She said she will connect with Councilor Guth on the housing ask. Regarding the hybrid option for P&Z and HPC, we have left this to the board’s discretion. Second, council would need to make appropriations and then find someone to do this job. Mayor Torre said we will continue the conversation. AGENDA AMENDMENTS: Mayor Torre said at the end of action items he would like to leave this open for food truck service. Ms. Ott asked him to take care of that now. Mayor Torre said there is an opportunity for another food truck this summer like last summer. At this time, he wants to know if everyone is on board. Councilor Hauenstein said he would like to see the taco truck come back. Councilor Hauenstein motioned to approve the taco truck; Councilor Doyle seconded. Ms. Ott suggested a motion. Councilor Hauenstein rephrased his motion as stated by the city manager. The seconder accepted. Councilor Guth suggested a second truck. Mayor Torre suggested to move forward with this and explained that our last attempt at an RFP for this was not that fruitful. Roll call vote: Doyle, yes; Guth, yes; Hauenstein, yes; Rose, yes; Torre, yes. 5-0, motion carried. CITY MANAGER COMMENTS: Ms. Ott said that regarding boards & commissions, it would be helpful to know their operating expectations. There are 16 of them and the staff liaison can only do so much. This is a possible work session topic. Please also think about ROW use downtown. Take some time this summer to examine these types of uses. She is concerned with what happens with dining and liquor services in the pedestrian malls. What is the desired experience you’re trying to create for the community. Mayor Torre suggested a site visit to walk the core together. Ms. Ott suggested July. She attended CML in Rifle last week and had a great conversation between Aspen and other elected officials. Issues dealing with funding and affordable housing and CDL driver safety. She said June 25th, she would like the community to join us at the Wheeler for a public art installation. Help us create a mural and she would love to see a great turnout and discuss the public art plan. She mentioned the cultural vibrancy grants opened yesterday through July 12 th. This is a pilot program for funding on big ideas. 21 3 REGULAR MEETING ASPEN CITY COUNCIL JUNE 6TH, 2023 BOARD REPORTS: Mayor Torre said he has a RFTA retreat on Thursday. Councilor Doyle said he has APCHA this week. CONSENT CALENDAR: Councilor Guth pulled Resolution #073. Councilor Hauensteinpulled Resolution #076 and #091. Councilor Guth commended the utilities department on Resolution #085. Resolution #073, Series of 2023 – Ainsley Brosnan-Smith and Tessa Schreiner Councilor Guth asked where each one of these compost containers are going and how will they be secured. Ms. Brosnan-Smith said this is part of the ordinance they previously passed in February, and she explained the details of that. These containers are for the CORE, and they worked with engineering on placing them in the ROW for restaurants. They can’t harness containers to the ground, but they are on wheels. These are specialized containers with a paddle latch system. Councilor Guth said this doesn’t address his questions. He continued the Q&A and suggested a smaller pilot program. Mayor Torre told him the voluntary program already exists. We want to move this forward. Councilor Rose asked to hear about the process. Councilor Hauenstein said this process started in 2021 and explained that staff spoke to all restaurants, and all were on board. Resolution #076 and #091, Series of 2023 – Linda Consuegra, Tim Karfs and Kim Ferber Councilor Hauensteinquestioned all of the vehicles recently bought and Ms. Ferber addressed. We’ve looked at EV and hybrids to replace other vehicles, so the Dodge Durangos became available. Currently we have five Teslas in effect, and this will be the 6 th. These aren’t new vehicles, just replacements. Ms. Ott made a clarification on the replacement of vehicles and explained this is an entire fleet issue. Councilor Hauenstein motioned to adopt the consent calendar; Councilor Doyle seconded. Roll call vote: Doyle, yes; Guth, yes; Hauenstein, yes; Rose, yes; Torre, yes. 5-0, motion carried. First Reading of Ordinance #11, Series of 2023 – House Bill 23-1225 – Haley Hart and Ben Anderson Councilor Doyle motioned to read; Councilor Hauenstein seconded. Roll call vote: Doyle, yes; Guth, yes; Hauenstein, yes; Rose, yes; Torre, yes. 5-0, motion carried. City clerk, Nicole Henning read the ordinance. Ms. Hart said their presentation is in response to the passing of House Bill 23-1255. She explained what an antigrowth law is. This pertains to residential only, no lodge or commercial. Mr. Anderson said the bill is going after a table like the one he showed on screen. He walked through the affordable housing implications with GMQ’s and other implications. 22 4 REGULAR MEETING ASPEN CITY COUNCIL JUNE 6TH, 2023 Ms. Hart explained staff’s response: temporary, non-renewable anti-growth law. “A temporary, non- renewable anti-growth law affecting property allowed by subsection (4)(a) of this section may be effective for no more than twenty-four months in any five-year period.” Staff recommends approval of Ordinance #11. This ordinance does not make changes to our code now but extends the applicability of the current LUC for two years while: staff conducts research, works with legal and planning consultants, allows time to bring LUC into compliance. Councilor Doyle motioned to approve; Councilor Hauenstein seconded. Councilor Guth asked if there is support for doing this in 12 months instead of 24. Mayor Torre reminded him that this is first reading and will come back for a public hearing and a bigger discussion. Roll call vote: Doyle, yes; Guth, yes; Hauenstein, yes; Rose, yes; Torre, yes. 5-0, motion carried. Mayor Torre called for a dinner break at 6:40 p.m. Council reconvened at 7:04 p.m. PUBLIC HEARINGS: Ordinance #10, Series of 2023 – Lumberyard Affordable Housing Project Major Public Project, Amendments to Official Zone District Map, Planned Development, Major Subdivision, Transportation & Parking, Growth Management Quota System – Chris Everson, Ben Anderson, Kevin Rayes, Cushing Terrell Architects, Mountain West Design Team of the Year: Laura Dougherty, Gyles Thornely, Randy Rhodes, and Nicole Olmstead. Mr. Anderson gave a brief introduction to the project and spoke about Community Developments role thus far. Mr. Everson provided where they’ve been, where we are now and where they are going. They will speak about site design and the project implementation and phasing. Mayor Torre called for a five-minute break at 8:55 and reconvened at 9:00 p.m. Mr. Everson continued with his presentation after Mayor Torre announced that we would be continuing this item after the due diligence portion of the presentation. Mr. Anderson said he can give the staff presentation at a continued date. Ms. Ott said council can hold a special meeting on June 13 th or continue to the next regular meeting on June 20th at 4:00 p.m. Councilor Hauensteinmotioned to continue to a special meeting on June 13 th at 4:00 p.m. for Ordinance #10; Series of 2023; Councilor Doyle seconded. Councilor Guth suggested starting at 3:00 p.m. Councilor Hauensteinamended his motion; Councilor Doyle seconded. Roll call vote: Doyle, yes; Guth, yes; Hauenstein, yes; Rose, yes; Torre, yes. 5-0, motion carried. Ms. Ott suggested council goals for their next work session for discussion. 23 5 REGULAR MEETING ASPEN CITY COUNCIL JUNE 6TH, 2023 BOARD & COMMISSION APPOINTMENTS: Councilor Guth asked to vote on these in public because the process is hard for him to understand, and he can’t give any meaningful feedback. Planning & Zoning Commission: Ken canfield 5-0, Eric Knight 4-1, Marcus Blue 5-0, Tracy Sutton 3-2 as alternate 1, Alexandra George, 2-3, Mazza Pitt 3-2 alternate 2. Historic Planning Commission: Kim Raymond 4-1, Riley Warwick 4-1 alternate. Next Generation: Bailey Everhart, 5-0. Kids First: Sara Lowe, 5-0 alternate. Grants Committee: Chris Menges, 5-0. Commercial Core & Lodging Commission: Noemi Kiss-Baldwin 4-1, Stephanie Davis, 4-1. Board of Adjustment: Tim Sack, 5-0 alternate. Animal Shelter: Adam Goldsmith: 5-0 regular, Allison Ratichek, 5-0 regular, Diane Wooslich, 4-1 alternate. APCHA: Peter Grenney 3-2. Councilor Hauensteinaffirmed the boards & commissions as stated by straw poll; Councilor Rose seconded. Mayor Torre said the process we’ve used for years has kept some negative talk away. But for transparency’s sake, this is a must. Roll call vote: Doyle, yes; Guth, yes; Hauenstein, yes; Rose, yes; Torre, yes. 5-0, motion carried. Councilor Rose motioned to adjourn; Councilor Doyle seconded. Roll call vote: Doyle, yes; Guth, yes; Hauenstein, yes; Rose, yes; Torre, yes. 5-0, motion carried. ___________________________ Nicole Henning, City Clerk 24 Page 1 of 3 Memorandum TO: Mayor Torre & Aspen City Council THRU: Ben Anderson, Deputy Community Development Director FROM: Sophie Varga, Planner MEETING DATE: July 25th, 2023 RE: 104 Midland Avenue and 108 Midland Avenue – Minor Amendment to Project Review, Ordinance #13, Series of 2023, First Reading APPLICANT/OWNER: Midland Properties, LLC REPRESENTATIVE: Sara Adams, Bendon Adams LOCATION: Street Addresses: 104 Midland Avenue & 108 Midland Avenue Legal Description: Lot A, Ferguson Exemption Lot 1, Ferguson Exemption Parcel Identification Numbers: PIDS# 2737-181-26-005, 2737-181-26-110, CURRENT ZONING & USE Moderate Density Residential (R-15A) with a Planned Development overlay; detached residential dwellings. PROPOSED ZONING & USE: No change proposed. SUMMARY: The applicant requests a Minor Amendment to Project Review for a Planned Development to remove a plat note restricting development on steep slopes. Staff recommends approval of the Amendment, subject to the conditions listed in the draft Ordinance. Figure 1: Site Location 25 Page 2 of 3 BACKGROUND: 108 Midland Avenue and 104 Midland Avenue are located in the Ferguson Exemption Subdivision. Each property is improved with a single-family dwelling. 104 Midland contains a shared driveway providing access to both dwellings. In 1980 the Board of County Commissioners granted a subdivision exemption for Lots 1-17 of the Riverside Addition, via Resolution 01, Series of 1980, creating four resulting parcels (Lots 1-4 of the Ferguson Subdivision Exemption, Plat Book 11, Page 59). The Ferguson Exemption Plat included a note restricting development on slopes over 30%. The subdivision was later annexed into the City and rezoned to Moderate Density Residential (R-15A) with a PUD overlay (Ordinance Numbers 16 & 18, Series of 1982, respectively). The Annexation Plat is recorded at Book 13, Page 65. In 1985 City Council further subdivided Lot 4 into Lots A and B of Lot 4 (Plat Recorded at Book 18, Page 66). REQUEST OF CITY COUNCIL: The Applicant is seeking the following land use approval: Minor Amendment to a Project Review Approval (Section 26.445.110.d): 1. Remove the following plat note on 104 Midland Avenue and 108 Midland Avenue: “Developement [sic] of slope over 30% is prohibited without approval from the Board of County Commissioners” Although the application represents a site-specific development plan on 108 Midland Avenue, the subject of this review is limited to removing the plat note and redevelopment of a shared driveway. STAFF COMMENTS: Staff supports the request to remove the plat note, subject to the conditions listed in the ordinance. The presence of steep slopes is not unique to these properties and the City of Aspen Municipal Code has been amended over time to minimize development impacts on this type of terrain. For instance, development rights are reduced on properties with slopes exceeding 30 percent. Additionally, the setback requirements prescribed pursuant to underlying zoning ensure the majority of development is concentrated in areas outside the steep slopes. Lastly, the Engineering and Parks Departments require certain construction methods and development techniques to reduce impacts on steep slopes. These referral agencies have reviewed the development proposal and don’t have any reservations about the proposal. 26 Page 3 of 3 RECOMMENDATION: Staff recommends that City Council approve the requests with the following Conditions of Approval: 1. The Applicant shall submit for review and recordation by the Community Development Director an amended plat within 180 days of the issuance of a development order. 2. The Applicant shall record an adjusted easement for the driveway on Lot A prior to submission of a permit. 3. The Applicant shall apply for and receive approval for all necessary permits to redevelop the driveway. PROPOSED MOTION: I move to approve Ordinance #13, Series of 2023, on First Reading. ATTACHMENTS: Ordinance #13, Series of 2023 Exhibit A – Detailed Staff Findings Exhibit B – Application 27 104 and 108 Midland Avenue, Ferguson Subdivision Exemption Ordinance #13, Series 2023 Page 1 of 3 ORDINANCE #13 (SERIES OF 2023) AN ORDINANCE OF THE ASPEN CITY COUNCIL GRANTING A MINOR AMENDMENT TO A PLANNED DEVELOPMENT FOR PROJECT REVIEW AT THE PROPERTIES COMMONLY KNOWN AS 104 MIDLAND AVENUE, LEGALLY DESCRIBED AS LOT A, FERGUSON SUBDIVISION EXCEPTION AND P.U.D. AMENDMENT, ACCORDING TO THE PLAT THEREOF RECORDED APRIL 30, 1986, IN PLAT BOOK 18 AT PAGE 66 AS RECEPTION NO. 277623 , COUNTY OF PITKIN, CITY OF ASPEN, STATE OF COLORADO; AND 108 MIDLAND AVENUE, LEGALLY DESCRIBED AS LOT 1, FERGUSON EXEMPTION PLAT, ACCORDING TO THE PLAT THEREOF RECORDED JUNE 1, 1981, IN PLAT BOOK 11 AT PAGE 59 AS RECEPTION NO. 233197, COUNTY OF PITKIN, CITY OF ASPEN, STATE OF COLORADO. Parcel IDs: 2737-181-26-005 & 2737-181-26-110 WHEREAS,the Community Development Department received an application from Midland Properties, LLC (Applicant), represented by Sara Adams, BendonAdams, requesting the following land use approval: Minor Amendment to a Planned Development for Project Review pursuant to Land Use Code Section 26.445.110.d, Minor Amendment to a Project Review WHEREAS,the Community Development Department referred the application to the Engineering and Parks Departments for comment; and, WHEREAS,the City of Aspen Community Development Department reviewed the proposed Application and recommended approval of the request; and, WHEREAS,the Aspen City Council has reviewed and considered the request under the applicable provisions of the Municipal Code as identified herein, has reviewed and considered the recommendations of the Community Development Director, the applicable referral agencies, and has taken and considered public comment at a public hearing; and, WHEREAS,City Council finds that the development proposal meets or exceeds all the applicable development standards; and, WHEREAS, on July 25, 2023, The Aspen City Council approved Ordinance #13, Series of 2023 by a ___ to ___ ( __ – __ ) vote at First Reading; and WHEREAS,City Council finds that this Ordinance furthers and is necessary for the promotion of public health, safety, and welfare. NOW, THEREFORE BE IT ORDAINED BY THE CITY OF ASPEN CITY COUNCIL AS FOLLOWS: 28 104 and 108 Midland Avenue, Ferguson Subdivision Exemption Ordinance #13, Series 2023 Page 2 of 3 Section 1: Minor Amendment to a Planned Development Amendment for Project Review Approval: Pursuant to the procedures and standards set forth in Title 26 of the Aspen Municipal Code, Council grants approval of a Minor Amendment to a Planned Development for Project Review of the Ferguson Subdivision Exemption, for the following: 1. Remove the following plat note on 104 and 108 Midland Avenue: “Developement [sic] of slope over 30% is prohibited without approval from the Board of County Commissioners”. Section 2: Conditions of Approval 1. The Applicant shall submit for review and recordation by the Community Development Director an amended plat within 180 days of the issuance of a development order. Section 3: Material Representations All material representations and commitments made by the Applicant pursuant to the development proposal approvals as herein awarded, whether in public hearing or documentation presented before the Community Development Department or the Aspen City Council are hereby incorporated in such plan development approvals and the same shall be complied with as if fully set forth herein, unless amended by other specific conditions or an authorized authority. Section 4: Existing Litigation This Ordinance shall not affect any existing litigation and shall not operate as an abatement of any action or proceeding now pending under or by virtue of the ordinances repealed or amended as herein provided, and the same shall be conducted and concluded under such prior ordinances. Section 5: Severability If any section, subsection, sentence, clause, phrase, or portion of this Ordinance is for any reason held invalid or unconstitutional in a court of competent jurisdiction, such portion shall be deemed a separate, distinct and independent provision and shall not affect the validity of the remaining portions thereof. INTRODUCED, READ AND ORDERED PUBLISHED as provided by law, by the City Council of the City of Aspen on the 25th day of July, 2023. Attest:Approved as to content: __________________________________________________________________ Nicole Henning, City Clerk Torre, Mayor 29 104 and 108 Midland Avenue, Ferguson Subdivision Exemption Ordinance #13, Series 2023 Page 3 of 3 FINALLY,adopted, passed and approved this 25th day of July, 2023. Approved as to form: Approved as to content: __________________________________________________________________ Jim True, City Attorney Torre, Mayor Attest: _______________________________ Nicole Henning, City Clerk 30 EXHIBIT A | DETAILED STAFF FINDINGS Sec. 26.445.110. - Amendments. Amendments to an approved Project Review or to an approved Detailed Review shall be reviewed according to the standards and procedures outline below. Amendments to Planned Unit Development and Specially Planned Area approvals (pre-Ordinance 36, 2013, approvals) shall also proceed according to the standards and procedures outline below and the Community Development Director shall determine the type of procedure most-applicable to the requested amendment. (d) Minor Amendment to a Project Review approval. An amendment found by the Community Development Director to be generally consistent with the allowances and limitations of a Project Review approval or which otherwise represents an insubstantial change but which does not meet the established thresholds for an insubstantial amendment, may be approved, approved with conditions or denied by the City Council, pursuant to 26.445.040(b)(2) - Step Two. An applicant may not apply for Detailed Review if an amendment is pending. Staff findings: Staff evaluated the origins of the plat note and the limitations on development of steep slopes going back to the Board of County Commissioners Approval. While the limitation was included in the entitlement documents, staff finds that subsequent amendments to the City of Aspen Municipal Code have addressed concerns related to potential development impacts on steep slopes. Staff finds that removal of the plat note is a technical amendment to the Planned Development and is consistent with the allowances and limitations established by the PD. The amendment is found to be a Minor Amendment to a Project Review. Staff finds the criteria met. Sec. 26.445.050. - Project Review Standards. The Project Review shall focus on the general concept for the development and shall outline any dimensional requirements that vary from those allowed in the underlying zone district. The burden shall rest upon an applicant to show the reasonableness of the development application and its conformity to the standards and procedures of this Chapter and this Title. The underlying zone district designation shall be used as a guide, but not an absolute limitation, to the dimensions which may be considered during the development review process. Any dimensional variations allowed shall be specified in the ordinance granting Project Approval. In the review of a development application for a Project Review, the Planning and Zoning Commission or the Historic Preservation Commission, as applicable, and City Council shall consider the following: a) Compliance with Adopted Regulatory Plans. The proposed development complies with applicable adopted regulatory plans. Staff findings: There are no applicable adopted regulatory plans. Staff finds the criteria not applicable. 31 EXHIBIT A | DETAILED STAFF FINDINGS b) Development Suitability. The proposed Planned Development prohibits development on land unsuitable for development because of natural or man-made hazards affecting the property, including flooding, mudflow, debris flow, fault ruptures, landslides, rock or soil creep, rock falls, rock slides, mining activity including mine waste deposit, avalanche or snow slide areas, slopes in excess of thirty percent (30%), and any other natural or man-made hazard or condition that could harm the health, safety, or welfare of the community. Affected areas may be accepted as suitable for development if adequate mitigation techniques acceptable to the City Engineer are proposed in compliance with Title 29—Engineering Design Standards. Conceptual plans for mitigation techniques may be accepted for this standard. The City Engineer may require specific designs, mitigation techniques, and implementation timelines be defined as part of the Detailed Review and documented within a Development Agreement. Staff findings: The application was referred to the Engineering Department for review. Engineering finds the properties suitable for development and does not have concerns regarding removing the plat note. Staff finds the criteria met. c) Site Planning. The site plan is compatible with the context and visual character of the area. In meeting this standard, the following criteria shall be used: 1. The site plan responds to the site's natural characteristics and physical constraints such as steep slopes, vegetation, waterways, and any natural or man-made hazards and allows development to blend in with or enhance said features. 2. The project preserves important geologic features, mature vegetation, and structures or features of the site that have historic, cultural, visual, or ecological importance or contribute to the identity of the town. 3. Buildings are oriented to public streets and are sited to reflect the neighborhood context. Buildings and access ways are arranged to allow effective emergency, maintenance, and service vehicle access. Staff Findings: The Minor Amendment is to remove the following Plat note: “[d]evelopment of slopes over 30% is prohibited without approval from the Board of County Commissioners”. This request was referred out to the City of Aspen Engineering and Parks Departments. Regulations adopted after the Plat was created in the municipal code manage the impacts of development on steep slopes. Setbacks prevent development near the property lines. Staff finds the criteria met. d) Dimensions. All dimensions, including density, mass, and height shall be established during the Project Review. A development application may request variations to any dimensional requirement of this Title. In meeting this standard, consideration shall be given to the following criteria: 1. There exists a significant community goal to be achieved through such variations. 32 EXHIBIT A | DETAILED STAFF FINDINGS 2. The proposed dimensions represent a character suitable for and indicative of the primary uses of the project. 3. The project is compatible with or enhances the cohesiveness or distinctive identity of the neighborhood and surrounding development patterns, including the scale and massing of nearby historical or cultural resources. 4. The number of off-street parking spaces shall be established based on the probable number of cars to be operated by those using the proposed development and the nature of the proposed uses. The availability of public transit and other transportation facilities, including those for pedestrian access and/or the commitment to utilize automobile disincentive techniques in the proposed development, and the potential for joint use of common parking may be considered when establishing a parking requirement. 5. The Project Review approval, at City Council's discretion, may include specific allowances for dimensional flexibility between Project Review and Detailed Review. Changes shall be subject to the amendment procedures of Section 26.445.110—Amendments. Staff Findings: The Ferguson Exemption Plat (Book 11, Page 59) did not establish dimensional standards, which means underlying zoning applies. The parcels are located in the Moderate-Density Residential (R-15A) Zone District and subject to the dimensional standards for the zone district. The Minor Amendment does not request a variation to these dimensions. Staff finds the criteria met. e) Design Standards. The design of the proposed development is compatible with the context and visual character of the area. In meeting this standard, the following criteria shall be used: 1. The design complies with applicable design standards, including those outlined in Chapter 26.410, Residential Design Standards, Chapter 26.412, Commercial Design Standards, and Chapter 26.415, Historic Preservation. 2. The proposed materials are compatible with those called for in any applicable design standards, as well as those typically seen in the immediate vicinity. Exterior materials are finalized during Detailed Review, but review boards may set forth certain expectations or conditions related to architectural character and exterior materials during Project Review. Staff Findings: A site specific development is not part of this request. Staff finds the criteria not applicable. f) Pedestrian, bicycle & transit facilities. The development improves pedestrian, bicycle, and transit facilities. These facilities and improvements shall be prioritized over vehicular facilities and improvements. Any vehicular access points, or curb cuts, minimize impacts on existing or proposed pedestrian, bicycle, and transit facilities. The City may require specific designs, mitigation techniques, and 33 EXHIBIT A | DETAILED STAFF FINDINGS implementation timelines be defined as part of the Detailed Review and documented within a Development Agreement. Staff Findings: The request does not impact pedestrian, bicycle, transit, or vehicular facilities. Staff finds the criteria not applicable. g) Engineering Design Standards. There has been accurate identification of engineering design and mitigation techniques necessary for development of the project to comply with the applicable requirements of Municipal Code Title 29— Engineering Design Standards and the City of Aspen Urban Runoff Management Plan (URMP). The City Engineer may require specific designs, mitigation techniques, and implementation timelines be defined as part of the Detailed Review and documented within a Development Agreement. Staff Findings: The request was referred to the Engineering department. Engineering staff supported request and will review design and mitigation techniques when the properties submits development proposals for building permit. Staff finds the criteria met. h) Public Infrastructure and Facilities. The proposed Planned Development shall upgrade public infrastructure and facilities necessary to serve the project. Improvements shall be at the sole costs of the developer. The City Engineer may require specific designs, mitigation techniques, and implementation timelines be defined as part of the Detailed Review and documented within a Development Agreement. Staff Findings: No infrastructure or facility upgrades are necessary for the request. Staff finds the criteria not applicable. i) Access and Circulation. The proposed development shall have perpetual unobstructed legal vehicular access to a public way. A proposed Planned Development shall not eliminate or obstruct legal access from a public way to an adjacent property. All streets in a Planned Development retained under private ownership shall be dedicated to public use to ensure adequate public and emergency access. Security/privacy gates across access points and driveways are prohibited. Staff Findings: Access and circulation will not be impacted by the request. Staff finds the criteria not applicable. 34 108 Midland Avenue Ferguson Subdivision Lot 1 PD Amendment January 30, 2023 35192 TABLE OF CONTENTS 04 10 14 64 Project summary and background A. Review Criteria B. Land Use Application Form F. Improvement survey including slope analysis dated August 2022 66 66 71 82 G. Civil engineering G.1 Intent to serve letters G.2 Civil drawings including grading and drainage G.3 Statements from civil engineer 16 16 23 D. Architecture D.1 Existing conditions D2 Proposed design set 48 50 D.3 Residential Design Standards D.4 Landscape Plan - existing and proposed 55 D.5 Renderings 60 61 61 D.6 Neighborhood context E. Past approvals E.1 2022 Demolition allotment development order 62 63 E.2 1981 Ferguson subdivision plat E.3 1982 Ferguson annexation plat 15 C. Vicinity map 87 H. Draft plat 36193 TABLE OF CONTENTS 88 I. Required land use forms 88 90 I.1. HOA Form and Neighbor Consent I.2 Authorization to represent 91 94 I.3 Pre-application summary I.4 Agreement to pay 95 I.5 Proof of ownership 106 I.6 Mailing list for adjacent properties within 300’ dated January 2023 37194 300 SO SPRING ST | 202 | ASPEN, CO 81611 970.925.2855 | BENDONADAMS.COM January 30, 2023 Aspen City Council c/o Garrett Larimer, Senior Planner Community Development Department Re: 108 Midland Avenue PD amendment Dear City Council and planning staff, Please accept this application to amend the Ferguson Exemption Subdivision Plat for Lot 1 - 108 Midland Avenue. 108 Midland is located along Midland and Cooper Avenues with access from Cooper Avenue via an access easement across Lot 4. Snyder Park abuts the north end of 108 Midland Avenue. The property is developed with a single family home and has received a 2022 demolition allotment to demolish the existing home and to construct a new single family home. This application requests approval to develop within a section of land designated on the original Figure 1: Ferguson Subdivision highlighted in blue. Star indicates subject property, 108 Midland Avenue. Page 4 of 110 38195 Ferguson Exemption Subdivision Plat as requiring specific approval for development activity. Background The Ferguson Subdivision Exemption was approved in 1981 by the Pitkin County Board of County Commissioners (BOCC). The 1981 subdivision exemption plat includes the following plat note “development of slope over 30% is prohibited as specifically delineated on the plat without approval from the Board of County Commissioners.” At the time, 108 Midland Avenue was almost all sloped terrain and the Pitkin County Code prohibited any development on slopes greater than 30%1. It can be assumed that the BOCC did not want (and was not legally allowed) to create a parcel that was undevelopable; and therefore placed a condition that enabled development within the 30% slope area upon additional review by the Board rather than just outright prohibit any development on the parcel. The County’s Code has since been amended to remove this absolute prohibition. Figure 2: 1980 Aspen GIS aerial map. Orange dotted line show general location of 108 Midland Avenue. 1 Pitkin County Land Use Code dated 1979, Section 5-401.2.h.1. Page 5 of 110 39196 In 1982 the Ferguson Subdivision neighborhood was annexed into the City of Aspen (Ordinance 16-1982) and zoned R15A-PUD (Ordinance 18-1982), which remains in place today. The “PUD” designation was common for developments approved in the County and then annexed into the City – as this legalized any existing non-conformities resultant from applying city zoning. The 1981 requirement for special BoCC approval in the sloped areas was never addressed during the annexation process and is not included on the annexation plat. The requirement remains on the original subdivision plat. A single family home is exempt from a planned development review per Section 26.445.020 Planned Development - Applicability, “in the absence of an approved site specific development plan, a single detached, two detached, or a duplex residential dwelling, if listed as a permitted use in the property’s zoning, may be developed in conformance with the provisions of the Zone District.” This property requests approval for development according to the 1981 plat note and in conformance with the provisions of the Zone District. Platted Slope verses Actual Slope The actual slopes on the property do not correlate to the “30% slope” area on the 1981 plat – the platted slopes. An analysis of the property shows that the actual 30% slopes (shown in blue) do not align with the 1981 platted slopes specifically in the area to the north of the existing house when comparing Figure 3 and Figure 4. Figure 3: 1981 Ferguson Exemption Plat. Blue area highlights the area indicates the platted 30% slope. Figure 4: 108 Midland Avenue 2022 survey with slopes. Blue highlight shows actual 30% slopes Page 6 of 110 40197 Request We respectfully request the ability to develop in the specified 30% sloped areas for the driveway, a small portion of the proposed new house, and the conversion of an existing curb cut into a walking pathway on Midland Avenue. Driveway realignment The existing driveway does not meet current Engineering Design Standards or Fire Code requirements regarding slopes, width, access right of way ramps, or turnaround space. In addition, the existing location of the driveway does not align with the driveway location on the 1981 plat. The proposed driveway cures the existing non-conformities and meets current City of Aspen Code requirements. The driveway is proposed within the platted 30% slope area; however, this is necessary to meet Engineering and Fire Codes. Renderings in Exhibit D demonstrate very minimal visual impact, if any, of the driveway realignment on the Midland Avenue pedestrian and vehicular experience. The diagram below shows the areas within the platted 30% slope impacted by the driveway realignment. A total of 795 sf of the platted 30% sloped area is proposed to be impacted. Figure 5 shows the impact on the platted slope and Figure 6 shows the impact on the actual slope. Figure 5: Detail of the proposed realigned driveway. Blue and orange highlights show areas within the platted 30% sloped area per the 1981 Ferguson subdivision plat. Figure 5: Detail of proposed realigned driveway with impacts on actual 30% slopes per the August 2022 survey shown in blue and orange. Page 7 of 110 41198 Single family home location The property owner received a demolition allotment to demolish and replace the aging and very energy inefficient single family home with a new house that meets the City’s energy and climate goals, and complies with R-15A zoning. The location of the proposed new home is similar to existing but pushed to the north slightly. A comparison of the proposed home location within the 1981 platted 30% slope (Exhibit 7) versus the actual slope condition (Exhibit 8) illustrates the minimal impact on actual slopes. A total of 461 sf of development is located within actual 30% sloped areas, and a total of 2,734 sf of development is located within the 1981 platted sloped area. Figure 7: Detail of the proposed home footprint. Orange highlights show areas within the platted 30% sloped area per the 1981 Ferguson subdivision plat. Figure 8: Detail of proposed home footprint with impacts on actual 30% slopes per the August 2022 survey shown in orange. Page 8 of 110 42199 Wa lking pathway from Midland Avenue An existing informal curb cut and vehicular access is located off Midland Avenue in the northwest corner of the property. This curb cut is proposed to be removed per Engineering requirements. A simple walking pathway is proposed to provide access to the sidewalk from the property as opposed to walking down the driveway. This proposed walkway, shown in Figure 10, adds to the pedestrian experience along Midland Avenue and does not impact any slopes as illustrated in Figure 8. As demonstrated in this application the existing home is over the allowable height and floor area for the property – this project proposes a compliant single family home that meets City of Aspen requirements including the Land Use Code, Engineering Design Standards, Building Code, and all other applicable requirements, and cures existing Engineering and Fire Code non-conformities. Thank you for your consideration of this application. Please reach out to schedule a site visit or if additional information is needed for your review. Kind Regards, Sara Adams, AICP BendonAdams, LLC Figure 9: Existing photograph of curb cut and informal vehicular access at left of photograph. Figure 6: Proposed walkway to replace informal curb cut. Page 9 of 110 43200 Exhibit A 108 Midland Avenue PD Review Criteria Sec. 26.445.110. Amendments. Amendments to an approved Project Review or to an approved Detailed Review shall be reviewed according to the standards and procedures outline below. Amendments to Planned Unit Development and Specially Planned Area approvals (pre-Ordinance 36, 2013, approvals) shall also proceed according to the standards and procedures outline below and the Community Development Director shall determine the type of procedure most-applicable to the requested amendment. (d) Minor Amendment to a Project Review approval. An amendment found by the Community Development Director to be generally consistent with the allowances and limitations of a Project Review approval or which otherwise represents an insubstantial change but which does not meet the established thresholds for an insubstantial amendment, may be approved, approved with conditions or denied by the City Council, pursuant to 26.445.040(b)(2) - Step Two. An applicant may not apply for Detailed Review if an amendment is pending. Response – As per the City of Aspen issued pre-application summary, this project qualifies as a minor amendment to a Project Review. Applicable review criteria are addressed below. Sec. 26.445.050. Project Review Standards. The Project Review shall focus on the general concept for the development and shall outline any dimensional requirements that vary from those allowed in the underlying zone district. The burden shall rest upon an applicant to show the reasonableness of the development application and its conformity to the standards and procedures of this Chapter and this Title. The underlying zone district designation shall be used as a guide, but not an absolute limitation, to the dimensions which may be considered during the development review process. Any dimensional variations allowed shall be specified in the ordinance granting Project Approval. In the review of a development application for a Project Review, the Planning and Zoning Commission or the Historic Preservation Commission, as applicable, and City Council shall consider the following: (a) Compliance with Adopted Regulatory Plans. The proposed development complies with applicable adopted regulatory plans. Response – There are no applicable adopted regulatory plans for 108 Midland Avenue. (b) Development Suitability. The proposed Planned Development prohibits development on land unsuitable for development because of natural or man-made hazards affecting the property, including flooding, mudflow, debris flow, fault ruptures, landslides, rock or soil creep, rock falls, rock slides, mining activity including mine waste deposit, avalanche or snow slide areas, slopes in excess of thirty percent (30%), and any other natural or man-made hazard or condition that could harm the health, safety, or welfare of the community. Affected areas may be accepted as suitable for development if adequate mitigation techniques acceptable to the City Engineer are proposed in compliance with Title 29—Engineering Design Standards. Conceptual plans for mitigation techniques may be accepted for this standard. The City Engineer may require specific designs, mitigation techniques, and implementation timelines be defined as part of the Detailed Review and documented within a Development Agreement. Response – A single family home is currently developed on the property and is proposed to be replaced with a fully compliant new single family home. The land is suitable for development. Areas in excess of 30% slope are mitigated according to the Engineering Design Standards as demonstrated in Exhibit G. Development is primarily focused on areas that are less than 30% slope and are already developed. Page 10 of 110 44201 Exhibit A 108 Midland Avenue PD Review Criteria (c) Site Planning. The site plan is compatible with the context and visual character of the area. In meeting this standard, the following criteria shall be used: (1) The site plan responds to the site's natural characteristics and physical constraints such as steep slopes, vegetation, waterways, and any natural or man-made hazards and allows development to blend in with or enhance said features. (2) The project preserves important geologic features, mature vegetation, and structures or features of the site that have historic, cultural, visual, or ecological importance or contribute to the identity of the town. (3) Buildings are oriented to public streets and are sited to reflect the neighborhood context. Buildings and access ways are arranged to allow effective emergency, maintenance, and service vehicle access. Response – The proposed site plan is similar to the existing site plan. The proposed home is sunken into the topography to minimize any visual impacts on Midland Avenue and from Snyder Park to the north. A comprehensive landscape plan is proposed to replant trees that are proposed to be removed in order to allow a realignment of the driveway to meet current Engineering Design Standards. (d) Dimensions. All dimensions, including density, mass, and height shall be established during the Project Review. A development application may request variations to any dimensional requirement of this Title. In meeting this standard, consideration shall be given to the following criteria: (1) There exists a significant community goal to be achieved through such variations. (2) The proposed dimensions represent a character suitable for and indicative of the primary uses of the project. (3) The project is compatible with or enhances the cohesiveness or distinctive identity of the neighborhood and surrounding development patterns, including the scale and massing of nearby historical or cultural resources. (4) The number of off-street parking spaces shall be established based on the probable number of cars to be operated by those using the proposed development and the nature of the proposed uses. The availability of public transit and other transportation facilities, including those for pedestrian access and/or the commitment to utilize automobile disincentive techniques in the proposed development, and the potential for joint use of common parking may be considered when establishing a parking requirement. (5) The Project Review approval, at City Council's discretion, may include specific allowances for dimensional flexibility between Project Review and Detailed Review. Changes shall be subject to the amendment procedures of Section 26.445.110—Amendments. Response – No variances from the underlying R-15 A zone district are requested. The simple form of the proposed home is contextual to the neighborhood. Existing and proposed dimensions are in Table 1. Page 11 of 110 45202 Exhibit A 108 Midland Avenue PD Review Criteria Table 1: Dimensional Requirements for R15-A and Net Lot Area of 11,264.25 sf Existing Allowed Proposed Floor area 4,821.72 sf 4,238.5 sf *4,488.6 sf with 1 TDR 4,462.97 sf *includes landing 1 TDR Maximum height 29’ 1 1/8” 25 feet 24’ 10.5” at highest point Front setback 25 feet 25 feet 25 feet Rear setback 10 feet 10 feet 10 feet Side setback 10 feet 10 feet 10 feet Distance between buildings n/a 10 feet ~11’ 2” The proposed project brings height and floor area into compliance with the underlying zone district as demonstrated in Table 1. (e) Design Standards. The design of the proposed development is compatible with the context and visual character of the area. In meeting this standard, the following criteria shall be used: (1) The design complies with applicable design standards, including those outlined in Chapter 26.410, Residential Design Standards, Chapter 26.412, Commercial Design Standards, and Chapter 26.415, Historic Preservation. (2) The proposed materials are compatible with those called for in any applicable design standards, as well as those typically seen in the immediate vicinity. Exterior materials are finalized during Detailed Review, but review boards may set forth certain expectations or conditions related to architectural character and exterior materials during Project Review. Response – The property complies with all applicable Residential Design Standards as demonstrated in Exhibit D. Proposed materials include wood siding, a stone base, and a metal roof. The roof is solar ready as demonstrated in Exhibit D, and will comply with the newly adopted Residential Demolition and Redevelopment Standards. (f) Pedestrian, bicycle & transit facilities. The development improves pedestrian, bicycle, and transit facilities. These facilities and improvements shall be prioritized over vehicular facilities and improvements. Any vehicular access points, or curb cuts, minimize impacts on existing or proposed pedestrian, bicycle, and transit facilities. The City may require specific designs, mitigation techniques, and implementation timelines be defined as part of the Detailed Review and documented within a Development Agreement. Response – The proposed home does not impact pedestrian, bicycle, or transit facilities. The improved driveway will meet URMP requirements which will capture drainage and runoff down the driveway that impacts the pedestrian experience along Midland Avenue. (g) Engineering Design Standards. There has been accurate identification of engineering design and mitigation techniques necessary for development of the project to comply with the applicable requirements of Municipal Code Title 29—Engineering Design Standards and the City of Aspen Urban Runoff Management Plan (URMP). The City Engineer may require specific designs, mitigation techniques, and implementation timelines be defined as part of the Detailed Review and documented within a Development Agreement. Response – Exhibit G addresses all Engineering Design Standards applicable at this point in the review process. Page 12 of 110 46203 Exhibit A 108 Midland Avenue PD Review Criteria (h) Public Infrastructure and Facilities. The proposed Planned Development shall upgrade public infrastructure and facilities necessary to serve the project. Improvements shall be at the sole costs of the developer. The City Engineer may require specific designs, mitigation techniques, and implementation timelines be defined as part of the Detailed Review and documented within a Development Agreement. Response – Intent to serve letters are included in Exhibit G. This project replaces an existing home that is currently served by public infrastructure. (i) Access and Circulation. The proposed development shall have perpetual unobstructed legal vehicular access to a public way. A proposed Planned Development shall not eliminate or obstruct legal access from a public way to an adjacent property. All streets in a Planned Development retained under private ownership shall be dedicated to public use to ensure adequate public and emergency access. Security/privacy gates across access points and driveways are prohibited. Response – 108 Midland shares a curb cut and driveway with 104 Midland as required by the Ferguson Subdivision plat. A realignment of the driveway is requested to meet current Engineering Design Standards regarding slope and stormwater management, which is proposed to be reflected on an updated plat that accurately depicts the driveway location. Page 13 of 110 47204 CITY OF ASPEN COMMUNITY DEVELOPMENT DEPARTMENT City of Aspen|130 S. Galena St.|(970) 920 5090 April 2020 LAND USE APPLICATION APPLICANT: REPRESENTIVATIVE: Description: Existing and Proposed Conditions Review: Administrative or Board Review Free Market dwelling units Essential Public Facility square footage Have you included the following? FEES DUE: $ Pre-Application Conference Summary Signed Fee Agreement HOA Compliance form All items listed in checklist on PreApplication Conference Summary Name: Address: Phone#: email: Address: Phone #: email: Name: Project Name and Address: Parcel ID # (REQUIRED) BendonAdams 300 South Spring Street, Suite 202, Aspen CO 81611 970.925.2855 Required Land Use Review(s): Growth Management Quota System (GMQS) required fields: x xx x 108 Midland Ave.; Aspen, CO 81611 2737-181-26-110 Midland Properties LLC 808 N. 5th Street; Alpine, TX 79830 sara@bendonadams.com common development, planned developments, minor amendment to project review approval 5,850 Propose to realign driveway and add new development in area noted on plat to require additional review . A minor plat amendment is requested to allow the proposed development to proceed. Lodge Pillows n/a 1Net Leasable square footage n/a Affordable Housing dwelling units n/a n/a Exhibit B Page 14 of 110 48205 101 115 111 201 131126 128 130 125 1230 115 121 127 133 146 138 139 104 108 118 116 114 112 110 110 1235 1195 101 100 107 110 220 515 514 ROBINSON RDLACE T L N E C O O P E R A V EPARK AVEARDMORE DRMIDLAND AVEARDMO R E C T Date: 9/22/2021 Geographic Information Systems This map/drawing/image is a graphical representation of the features depicted and is not a legal representation. The accuracy may change depending on the enlargement or reduction. Copyright 2021 City of Aspen GIS 0 0.01 0.020.01 mi When printed at 8.5"x11" 4 Legend Urban Growth Boundary (UGB) Emissions Inventory Boundary (EIB) City of Aspen Greenline 8040 Stream Margin Hallam Bluff ESA Historic Sites Historic Districts Parcels Roads Zoomed In Scale: 1:1,226 108 Midland Ave. Vicinity Map Exhibit C Page 15 of 110 49206 Lower Level Wall Label Total Wall Area (Sq Ft) Exposed Wall Area (Sq Ft) Unexposed Wall Area 101X 59.00 0.00 59.00 102X 47.00 0.00 47.00 103X 57.00 38.00 19.00 104X 26.00 2.00 24.00 105X 22.00 2.00 20.00 106X 26.00 2.00 24.00 107X 54.00 37.00 17.00 108X 125.00 0.00 125.00 109X 60.00 0.00 60.00 110X 92.00 0.00 92.00 111X 30.00 0.00 30.00 112X 90.00 0.00 90.00 113X 199.00 185.00 14.00 114X 162.00 49.00 113.00 115X 59.00 0.00 59.00 116X 97.00 0.00 97.00 Overall Total Wall Area (Sq Ft)287.00 Exposed Wall Area (Sq Ft)41.00 % of Exposed Wall (Exposed / Total)14.29% UnExposed Wall Area (Sq Ft)246.00 % of UnExposed Wall (UnExposed / Total)85.71% Main Level Wall Label Total Wall Area (Sq Ft)Exposed Wall Area (Sq Ft) Unexposed Wall Area 201X 258.00 258.00 0.00 202X 56.00 56.00 0.00 203X 56.00 56.00 0.00 204X 76.00 76.00 0.00 205X 56.00 56.00 0.00 206X 139.00 139.00 0.00 207X 64.00 64.00 0.00 208X 97.00 84.00 13.00 209X 32.00 27.00 5.00 210X 96.00 90.00 6.00 211X 36.00 36.00 0.00 212X 112.00 112.00 0.00 213X 177.00 177.00 0.00 214X 112.00 112.00 0.00 215X 62.00 62.00 0.00 216X 104.00 93.00 0.00 Overall Total Wall Area (Sq Ft)1,533.00 Exposed Wall Area (Sq Ft)1,498.00 % of Exposed Wall (Exposed / Total)97.72% UnExposed Wall Area (Sq Ft)24.00 % of UnExposed Wall (UnExposed / Total)1.57% Subgrade Wall Area (Existing) 108 Midland Avenue, Aspen, CO 81611 Existing Lower Level Wall Calculations Lower Level Wall Label Total Wall Area (Sq Ft) Exposed Wall Area (Sq Ft) Unexposed Wall Area 101 59.00 0.00 59.00 102 47.00 0.00 47.00 103 57.00 38.00 19.00 104 26.00 2.00 24.00 105 22.00 2.00 20.00 106 26.00 2.00 24.00 107 54.00 37.00 17.00 108 125.00 0.00 125.00 109 60.00 0.00 60.00 110 92.00 0.00 92.00 111 30.00 0.00 30.00 112 90.00 0.00 90.00 113 199.00 185.00 14.00 114 162.00 49.00 113.00 115 59.00 0.00 59.00 116 97.00 0.00 97.00 Overall Total Wall Area (Sq Ft)1,205.00 Exposed Wall Area (Sq Ft)315.00 % of Exposed Wall (Exposed / Total)26.14% UnExposed Wall Area (Sq Ft)890.00 % of UnExposed Wall (UnExposed / Total)73.86% Main Level Wall Label Total Wall Area (Sq Ft)Exposed Wall Area (Sq Ft) Unexposed Wall Area 201 258.00 258.00 0.00 212 56.00 56.00 0.00 203 56.00 56.00 0.00 204 76.00 76.00 0.00 205 56.00 56.00 0.00 206 139.00 139.00 0.00 207 64.00 64.00 0.00 208 97.00 84.00 13.00 209 32.00 27.00 5.00 210 96.00 90.00 6.00 211 36.00 36.00 0.00 212 112.00 112.00 0.00 213 177.00 177.00 0.00 214 112.00 112.00 0.00 215 62.00 62.00 0.00 216 104.00 93.00 0.00 Overall Total Wall Area (Sq Ft)1,533.00 Exposed Wall Area (Sq Ft)1,498.00 % of Exposed Wall (Exposed / Total)97.72% UnExposed Wall Area (Sq Ft)24.00 % of UnExposed Wall (UnExposed / Total)1.57% Subgrade Wall Area (Proposed) 108 Midland Avenue, Aspen, CO 81611 Existing Lower Level Wall Calculations SUBGRADE EXPOSED AREA SUB-GRADE AREA Z0.06X EXISTING SUBGRADE CALCULATIONS NOT FOR CONSTRUCTION 1/30/2023COUNCIL + ANDERSSON / WISE 807 Brazos St #800 Austin TX 78701 RED 1001 Grand Ave #103 Glenwood Springs CO 81601 © These documents have been specifically prepared for 108 Midland Ave. They are not suitable for use on other projects or in other locations without the approval and participation of the architect. Reproduction prohibited without approval of the architect. 2023 108 Midland Avenue 108 Midland Ave Aspen, CO 81611 59 sq ft 47 sq ft 162 sq ft 201X 202X 203X 204X 205X 206X 209X 210X 211X 212X 213X 214X 215X 216X207X208X 96 sq ft 36 sq ft 112 sq ft326 sq ft 56 sq ft 56 sq ft 76 sq ft 56 sq ft 139 sq ft 64 sq ft 97 sq ft 32 sq ft 177 sq ft 240 sq ft 349 sq ft 140 sq ft 13 sq ft 6 sq ft 6 sq ft 59 sq ft 47 sq ft 54 sq ft 13 sq ft 26 sq ft 22 sq ft 26 sq ft 6 sq ft 11 sq ft6 sq ft8'-1/4"7'-6 1/2"8'-1/4"2'5'-6 1/2"7'-9 1/2"6'-3"7'-6 1/2"3'-5"2'-10 1/2"3'-5"7'-2 1/2"16'-6 3/4"7'-11 1/2"12'-1 3/4"3'-11 1/2"11'-11"26'-5 1/4"21'-5 1/2"7'-9 1/2"12'-11" 32'-2"6'-11 1/2"6'-11 1/2"9'-6"6'-11 1/2"17'-3 3/4"7'-11 1/2"12'-1 3/4"3'-11 1/2"11'-11"4'-6"13'-11 1/2"22'-3/4"22'-1 1/2"32'-2"12'-11" 57 sq ft 54 sq ft 30 sq ft92 sq ft60 sq ft125 sq ft 90 sq ft 199 sq ft 24 sq ft 20 sq ft 24 sq ft 7 sq ft 7 sq ft 5 sq ft 59 sq ft 97 sq ft 150 sq ft WW 38 sq ft WW 38 sq ft 101X EXISTING GRADE 102X 103X 104X 105X 106X 109X 110X 91'-6" T.O. CONC. - LOWER LEVEL 111X 112X 113X 114X 115X 116X 100'-0" T.O. STRUCT. - MAIN LEVEL 107'-10" B.O. STRUCT. - UPPER LEVEL 99'-2" B.O. STRUCT. - MAIN LEVEL 107X 108X EXISTING GRADE 91'-6" T.O. CONC. - LOWER LEVEL 100'-0" T.O. STRUCT. - MAIN LEVEL 107'-10" B.O. STRUCT. - UPPER LEVEL 99'-2" B.O. STRUCT. - MAIN LEVEL 100'-0" T.O. STRUCT. - GARAGE 125 sq ft 60 sq ft 93 sq ft 30 sq ft 90 sq ft 59 sq ft 97 sq ft PATIO 185 sq ft SCALE: 1/8" = 1'-0"1Exsting Subgrade Calculations 0 4'8'16' Page 16 of 110 50207 Z0.07X EXISTING FAR CALCULATIONS NOT FOR CONSTRUCTION 1/30/2023COUNCIL + ANDERSSON / WISE 807 Brazos St #800 Austin TX 78701 RED 1001 Grand Ave #103 Glenwood Springs CO 81601 © These documents have been specifically prepared for 108 Midland Ave. They are not suitable for use on other projects or in other locations without the approval and participation of the architect. Reproduction prohibited without approval of the architect. 2023 108 Midland Avenue 108 Midland Ave Aspen, CO 81611 DECK AREAS (Land Use Code, 26.575.020.4) THE CALCULATION OF FLOOR AREAS SHALL NOT INCLUDE DECKS OR EXTERIOR STAIRWAYS UNLESS THE AREA OF THESE FEATURES IS GREATER THAN 15% OF THE ALLOWABLE FLOOR AREA FOR THE PROPERTY. IF THE AREA OF THSES FEATURES EXCEEDS 15% OF THE PROPERTY'S ALLOWABLE FLOOR AREA, ONLY THE AREAS IN EXCESS OF 15% SHALL BE ATTRIBUTED TOWARDS THE ALLOWABLE FLOOR AREA. GARAGE EXEMPTION (Land Use Code, 26.575.020-2) IN ZONE DISTRICTS OTHER THAN THE R-15B ZONE DISTRICT, PROPERTIES CONTAINING SOLELY A SINGLE -FAMILY, TWO (2) SINGLE FAMILY RESIDENCES , OR A DUPLEX , THE GARAGE AND CARPORT AREA SHALL BE EXCLUDED FROM THE CALCULATION OF FLOOR AREA AS FOLLOWS : Table 26.575.020-2 SIZE OF GARAGE AREA EXCLUDED PER PRIMARY DWELLING UNIT (NOT INCLUDING OR CARPORT ACCESSORY DWELLING UNITS OR CARRIAGE HOUSES) FIRST 0-250 SF 100% OF THE AREA NEXT 251-500 SF 50% OF THE AREA AREAS ABOVE 500 SF NO AREA EXCLUDED PATIO AREAS (Land Use Code, 26.575.020.6) PATIOS DEVELOPED AT OR WITHIN 6 INCHES OF FINISHED GRADE SHALL NOT BE COUNTED TOWARDS FLOOR AREA. WHEN ROOF OVERHANDS OR SIMILAR ARCHITECTURAL PROJECTIONS EXCEED 4 FEET, THE ENTIRE COUNTS TOWARDS FLOOR AREA. FLOOR AREA RATIO (Land Use Code) THE TOTAL FLOOR AREA OF ALL STRUCTURES ON A LOT DIVIDED BY THE LOT AREA. FLOOR AREA (Land Use Code) THE SUM TOTAL OF THE GROSS HORIZONTAL AREAS OF EACH STORY OF THE BUILDING MEASURED FROM THE EXTERIOR WALLS OF THE BUILDING. (SEE SUPPLEMENTARY REGULATIONS - SECTION 26.575.020, CALCULATIONS AND MEASUREMENTS STAIR AND ELEVATOR EXEMPTION (Land Use Code 26.575.020.D) WHEN CALCULATING VERTICAL CIRCULATION, THE CIRCULATION ELEMENT SHALL BE COUNTED AS FOLLOWS: A) FOR STAIRS AND ELEVATORS , THE AREA OF THE FEATURE SHALL BE PROJECTED DOWN AND COUNTED ON THE LOWEROF THE TWO LEVELS CONNECTED BY THE ELEMENT AND NOT COUNTED AS FLOOR AREA ON THE TOP-MOST INTERIOR FLOOR SERVED BY THE ELEMENT. MINIMUM NET LOT AREA PER DWELLING UNIT (SQUARE FEET) ( Land Use Code 26.710.060) A) DETACHED RESIDENTIAL DWELLING: FIFTEEN THOUSAND (15,000). FOR HISTORIC LANDMARK PROPOERTIES: THREE THOUSAND (3000) B) DUPLEX: SEVEN THOUSAND, FIVE HUNDRED (7,500). FOR HISTORIC LANDMARK PROPOERTIES: THREE THOUSAND (3000) C) BED AND BREAKFAST, BOARDINGHOUSE: NO REQUIREMENT FAR FLOOR AREA GARAGE DECK EXEMPT BUILT INPLANTER FLOOR AREA (Land Use Code) THE SUM TOTAL OF THE GROSS HORIZONTAL AREAS OF EACH STORY OF THE BUILDING MEASURED FROM THE EXTERIOR WALLS OF THE BUILDING. (SEE SUPPLEMENTARY REGULATIONS - SECTION 26.575.020, CALCULATIONS AND MEASUREMENTS MINIMUM NET LOT AREA PER DWELLING UNIT (SQUARE FEET) ( Land Use Code 26.710.060) A) DETACHED RESIDENTIAL DWELLING: FIFTEEN THOUSAND (15,000). FOR HISTORIC LANDMARK PROPOERTIES: THREE THOUSAND (3000) B) DUPLEX: SEVEN THOUSAND, FIVE HUNDRED (7,500). FOR HISTORIC LANDMARK PROPOERTIES: THREE THOUSAND (3000) C) BED AND BREAKFAST, BOARDINGHOUSE: NO REQUIREMENT N16'-6 3/4"12'-1 3/4"7'-2 1/8"22'-1 1/2"7'-9 1/2" 7'-9 1/2"12'-11"11'-11"22'-1 1/2"16'-6 3/4"12'-1 3/4"7'-2 1/8"22'-1 1/2"7'-9 1/2" 7'-9 1/2"12'-11"11'-11"22'-1 1/2"14'-10 1/4"102X 103X 104X 105X 106X 107X 108X 109X 110X 111X 112X 114X 115X 116X 101X UPD I 2 2 10 10 9 9 6 6 4 4 1 1 3 3 7 7 5 5 A B C H K J G 8 8 E F 11 11 26'-5 1/4"26'-5 1/4" 113X EXISTING BASEMENT 1,168 sq ft EXISTING COVERED PATIO 349 sq ft DECK 64 sq ft EXEMPT GARAGE 250 sq ft GARAGE NON-EXEMPT 142 sq ft26'-3"32'-1 1/2"22'-1 1/2"22'-3/4"6'-11 1/2"32'-2" 6'-11 1 / 2 " 9'-6"6'-11 1/ 2 "11'-11"4'-5 1/2"13'-11 1/2"17'-3 3/4"3'-11 1/2"12'-1 3/4"7'-11 1/2" 202X 203X 204X 205X 206X 207X 208X 209X 210X 211X214X 215X 216X 201X 212X 213X DECK 96 sq ft D I 2 2 10 10 9 9 6 6 4 4 1 1 3 3 7 7 5 5 A B C H K J G 8 8 E F 11 11 GARAGE @ 50% 250 sq ft EXISTING FIRST FLOOR 1,592 sq ft EXEMPT STAIR DECK 901 sq ft D I 2 2 10 10 9 9 6 6 4 4 1 1 3 3 7 7 5 5 A B C H K J G 8 8 E F 11 11 DECK 172 sq ft EXISTING SECOND FLOOR 1,389 sq ft DECK 64 sq ft EXEMPT STAIR NET LOT AREA ZONE DISTRICT REQUIREMENTS REFERENCE MIN. GROSS LOT AREA (PER R-15A)15, 000 SF 26.710.060 MIN. NET LOT AREA (PER R-15A)15, 000 SF 26.710.060 LOT SIZE PER SURVEY 15,019.00 REFERENCE REDUCTIONS FOR AREA WITH SLOPES 0%-20% (100% OF PARCEL AREA TO BE INCLUDED IN THE NET LOT AREA)15,019 x 25%SURVEY 26.575.020-1 TOTAL AREA REDUCTIONS 15,019 - 3754.75 NET LOT AREA 11,264.25 SF ALLOWABLE FLOOR AREA 4,080 SF OF FLOOR AREA, PLUS 7 SF PER EACH ADD'L 100 SF 11,264.25 - 9,000 = 2,264.25 2,264.25/ 100 = 22.64 22.64*7 = 158.5 SF 4, 080 SF + 158.5 SF = 4,238.5 SF TOTAL ALLOWABLE AREA 4238.5 SF ALLOWABLE EXEMPT DECK 4238.5 x 15% = 635.78 FLOOR AREA BASEMENT AREA (2,048 x 11.74%) 349.9719 FIRST FLOOR AREA (2,119 x 87.10%) 2,039.54 GARAGE LEVEL (250 SF EXEMPT) 250 GARAGE LEVEL (250 x 50%)125 GARAGE LEVEL ( NOT EXEMPT 267 SF x 96.25%)256.9875 SECOND FLOOR AREA 1,389 TOTAL FLOOR AREA 4410.4969 4,410.50 - 250 = 4,160.50 SF FIRST FLOOR DECK 160 SECOND FLOOR DECK 1137 TOTAL DECK 1297 ALLOWABLE EXEMPT DECK 635.78 TOTAL DECK FLOOR AREA 1297 - 635.78 = 661.22 SF TOTAL FLOOR AREA 4,160.50 + 661.22 4,821.72 SF 4238.5 - 4,821.72 583.22 THE EXISTING HOUSE IS 583.22 SF OVER THE ALLOWABLE AREA SCALE: 1/8" = 1'-0"1Existing Basement FAR 0 4'8'16'SCALE: 1/8" = 1'-0"2Existing First Floor FAR 0 4'8'16'SCALE: 1/8" = 1'-0"3Existing Second Floor FAR 0 4'8'16' Page 17 of 110 51208 Z0.08X EXISTING NET LIVABLE CALCULATIONS NOT FOR CONSTRUCTION 1/30/2023COUNCIL + ANDERSSON / WISE 807 Brazos St #800 Austin TX 78701 RED 1001 Grand Ave #103 Glenwood Springs CO 81601 © These documents have been specifically prepared for 108 Midland Ave. They are not suitable for use on other projects or in other locations without the approval and participation of the architect. Reproduction prohibited without approval of the architect. 2023 108 Midland Avenue 108 Midland Ave Aspen, CO 81611 NET LIVABLE AREA NET LIVABLE AREA NET LIVEABLE AREA THE AREAS WITHIN A BUILDING DESIGNED TO BE USED FOR HABITATIONAND HUMAN ACTIVITY NUPD I 2 2 10 10 9 9 6 6 4 4 1 1 3 3 7 7 5 5 A B C H K J G 8 8 E F 11 11 EXISTING BASEMENT 1,026 sq ft DECK 64 sq ft DECK 96 sq ft 2 2 10 10 9 9 6 6 4 4 1 1 3 3 7 7 5 5 8 8 11 11 EXISTING FIRST FLOOR 2,121 sq ft DECK DECK DECK D I 2 2 10 10 9 9 6 6 4 4 1 1 3 3 7 7 5 5 A B C H K J G 8 8 E F 11 11 EXISTING SECOND FLOOR 1,382 sq ft SCALE: 1/8" = 1'-0"1Existing Basement Net Livable 0 4'8'16'SCALE: 1/8" = 1'-0"2Existing First Floor Net Livable 0 4'8'16'SCALE: 1/8" = 1'-0"3Existing Second Floor Net Livable 0 4'8'16' EXISTING NET LIVABLE AREA BASEMENT AREA 1,026 SF FIRST FLOOR AREA 2,121 SF SECOND FLOOR AREA 1,382 SF TOTAL EXISTING NET LIVABLE AREA 4,529 SF Page 18 of 110 52209 Z0.09X EXISTING MITIGATION CALCULATIONS NOT FOR CONSTRUCTION 1/30/2023COUNCIL + ANDERSSON / WISE 807 Brazos St #800 Austin TX 78701 RED 1001 Grand Ave #103 Glenwood Springs CO 81601 © These documents have been specifically prepared for 108 Midland Ave. They are not suitable for use on other projects or in other locations without the approval and participation of the architect. Reproduction prohibited without approval of the architect. 2023 108 Midland Avenue 108 Midland Ave Aspen, CO 81611 FLOOR AREA MITIGATION DEFINITION (Land Use Code, 26.575.020-2) FLOOR AREA SHALL BE ATTRIBUTED TO THE LOT OR PARCEL UPON WHICH IT IS DEVELOPED . IN MEASUREING A BUILDING FOR THE PURPOSES OF CALCULATING FLOOR AREAS, THERE SHALL BE INCLUDED ALL AREAS WITHIN THE SURROUNDING EXTERIOR WALLS OF THE BUILDING. WHEN MEASURING FROM THE EXTERIOR WALLS, THE MEASUREMENT SHALL BE TAKEN FROM THE EXTERIOR FACE OF FRAMING, EXTERIOR FACE OF STRUCTURAL BLOCK, EXTERIOR FACE OF STRAW BALE, OR SIMILAR EXTERIOR SURFACE OF THE NOMINAL STRUCTURE EXCLUDING SHEATHING, VAPOR BARRIER , WEATHERPROOFING MEMBRANE, EXTERIOR-MOUNTED INSULATION SYSTEMS, AND EXCLUDING ALL EXTERIOR VENEER AND SURFACE TREATMENTS SUCH AS STONE, STUCCO, BRICKS, SHINGLES, CLAPBOARDS, OR OTHER SIMILAR EXTERIOR VENEER TREATMENTS. Table 26.575.020-2 SIZE OF GARAGE AREA EXCLUDED PER PRIMARY DWELLING UNIT OR CARPORT (NOT INCLUDING ACCESSORY DWELLING UNITS OR CARRIAGE HOUSES) FIRST 0-250 SF 100% OF THE AREA NEXT 251-500 SF 50% OF THE AREA AREAS ABOVE 500 SF NO AREA EXCLUDED MITIGATION MITIGATION AREA NUPD I 2 2 10 10 9 9 6 6 4 4 1 1 3 3 7 7 5 5 A B C H K J G 8 8 E F 11 11 EXISTING BASEMENT 1,080 sq ft DECK DECK 2 2 10 10 9 9 6 6 4 4 1 1 3 3 7 7 5 5 8 8 11 11 EXISTING FIRST FLOOR 2,268 sq ft DECK DECK DECK D I 2 2 10 10 9 9 6 6 4 4 1 1 3 3 7 7 5 5 A B C H K J G 8 8 E F 11 11 EXISTING SECOND FLOOR 1,384 sq ft SCALE: 1/8" = 1'-0"1Existing Basement Mitigation 0 4'8'16'SCALE: 1/8" = 1'-0"2Existing First Floor Mitigation 0 4'8'16'SCALE: 1/8" = 1'-0"3Existing Second Floor Mitigation 0 4'8'16' EXISTING MITIGATION AREA BASEMENT AREA 1,080 SF FIRST FLOOR AREA 2,268 SF SECOND FLOOR AREA 1,384 SF TOTAL MITIGATION AREA 4,732 SF Page 19 of 110 53210 Z0.10X EXISTING GROSS FIRE AREA CALCULATIONS NOT FOR CONSTRUCTION 1/30/2023COUNCIL + ANDERSSON / WISE 807 Brazos St #800 Austin TX 78701 RED 1001 Grand Ave #103 Glenwood Springs CO 81601 © These documents have been specifically prepared for 108 Midland Ave. They are not suitable for use on other projects or in other locations without the approval and participation of the architect. Reproduction prohibited without approval of the architect. 2023 108 Midland Avenue 108 Midland Ave Aspen, CO 81611 FIRE AREA THE AGGREGATE FLOOR AREA ENCLOSED AND BOUNDED BY FIRE WALLS, EXTERIOR WALLS, OR FIRE-RESITANCE RATED HORIZONTAL ASSEMBLIES OF A BUILDING . AREAS OF THE BUILDING NOT PROVIDED WITH SURROUNDING WALLS SHALL BE INCLUDED IN THE FIRE AREA IF SUCH AREAS ARE INCLUDED WITHIN THE HORIZONTAL PROJECTION OF THE ROOF OR FLOOR ABOVE. GROSS AREA GROSS AREA COVEREDOUTDOOR AREA NCOVERED AREA 350 sq ft UPD I 2 2 10 10 9 9 6 6 4 4 1 1 3 3 7 7 5 5 A B C H K J G 8 8 E F 11 11 EXISTING BASEMENT GROSS AREA 1,093 sq ft DECK DECK 2 2 10 10 9 9 6 6 4 4 1 1 3 3 7 7 5 5 8 8 11 11 COVERED AREA 161 sq ft EXISTING FIRST FLOOR GROSS AREA 2,268 sq ft EXISTING SECOND LEVEL GROSS AREA 1,485 sq ft DECK DECK D I 2 2 10 10 9 9 6 6 4 4 1 1 3 3 7 7 5 5 A B C H K J G 8 8 E F 11 11 SCALE: 1/8" = 1'-0"1Existing Basement Gross Area 0 4'8'16'SCALE: 1/8" = 1'-0"2Existing First Floor Gross Area 0 4'8'16'SCALE: 1/8" = 1'-0"3Existing Second Floor Gross Area 0 4'8'16' GROSS FIRE AREA BASEMENT AREA 1,093 SF FIRST FLOOR AREA 2,268 SF SECOND FLOOR AREA 1,485 SF COVERED EXTERIOR AREA 511 SF TOTAL GROSS FIRE AREA 5,357 SF Page 20 of 110 54211 Z0.13X HEIGHT OVER TOPOGRAPHY NOT FOR CONSTRUCTION 1/30/2023COUNCIL + ANDERSSON / WISE 807 Brazos St #800 Austin TX 78701 RED 1001 Grand Ave #103 Glenwood Springs CO 81601 © These documents have been specifically prepared for 108 Midland Ave. They are not suitable for use on other projects or in other locations without the approval and participation of the architect. Reproduction prohibited without approval of the architect. 2023 108 Midland Avenue 108 Midland Ave Aspen, CO 81611 DEFINITIONS (SECTION 26.104.100) HEIGHT, BUILDING THE HEIGHT OF A BUILDING SHALL BE THE MAXIMUM DISTANCE POSSIBLE MEASURED VERTICALLY FROM NATURAL GRADE AT ANY POINT WITHIN THE INTERIOR OF THE BUILDING; AND FROM NATURAL OR FINISHED GRADE (WHICHEVER IS LOWER) AT ANY POINT AROUND THE PERIMETER OF THE BUILDING TO THE HIGHEST POINT OR STRUCTURE WITHIN A VERICAL PLANE. (SEE SUPPLEMENARY REGULATIONS SECTION 26.575.020, MEASURMENT AND CALCULATIONS). HEIGHT OVER TOPOGRAPHY HEIGHTS ARE MEASURED TO THE MOST RESTRICTIVE GRADE.N4 Z0.14X 1 Z0.14X 2 Z0.14X A LINE OF WALL BELOW HEIGHT OVER TOPO MEASURED PER COA MUNICIPAL CODE CHAPTER 26.575.020 EXISTINGEXISTINGEXISTING EXISTINGEXISTING DECK BELOW SCALE: 1/4" = 1'-0"1Existing Height Over Topography 0 2'4'8' A - ROOF LABEL ROOF HEIGHT ROOF HEIGHT - 8003'-1 1/8" 29'-1 1/8" SITE EXISITING - 7974'" Page 21 of 110 55212 Z0.14X HEIGHTS NOT FOR CONSTRUCTION 1/30/2023COUNCIL + ANDERSSON / WISE 807 Brazos St #800 Austin TX 78701 RED 1001 Grand Ave #103 Glenwood Springs CO 81601 © These documents have been specifically prepared for 108 Midland Ave. They are not suitable for use on other projects or in other locations without the approval and participation of the architect. Reproduction prohibited without approval of the architect. 2023 108 Midland Avenue 108 Midland Ave Aspen, CO 81611 HEIGHT OVER TOPOGRAPHY HEIGHTS ARE MEASURED TO THE MOST RESTRICTIVE GRADE. DEFINITIONS (SECTION 26.104.100) HEIGHT, BUILDING THE HEIGHT OF A BUILDING SHALL BE THE MAXIMUM DISTANCE POSSIBLE MEASURED VERTICALLY FROM NATURAL GRADE AT ANY POINT WITHIN THE INTERIOR OF THE BUILDING; AND FROM NATURAL OR FINISHED GRADE (WHICHEVER IS LOWER) AT ANY POINT AROUND THE PERIMETER OF THE BUILDING TO THE HIGHEST POINT OR STRUCTURE WITHIN A VERICAL PLANE. (SEE SUPPLEMENARY REGULATIONS SECTION 26.575.020, MEASURMENT AND CALCULATIONS). A B C D G H I J KEF H G D C B AKJIEF 10 9 8 7 6 5 4 3 2 111 29'-1 1/8"1 2 3 4 5 6 7 8 9 10 SCALE: 1/8" = 1'-0"2Existing East Elevation 0 4'8'16' SCALE: 1/8" = 1'-0"4Existing West Elevation 0 4'8'16' SCALE: 1/8" = 1'-0"1Existing North Elevation 0 4'8'16' SCALE: 1/8" = 1'-0"3Existing South Elevation 0 4'8'16' A - ROOF LABEL ROOF HEIGHT ROOF HEIGHT - 8003'-1 1/8" 29'-1 1/8" SITE EXISITING - 7974'" Page 22 of 110 56213 COVER.1 COVER SHEET NOT FOR CONSTRUCTION 1/30/2023COUNCIL + ANDERSSON / WISE 807 Brazos St #800 Austin TX 78701 RED 1001 Grand Ave #103 Glenwood Springs CO 81601 © These documents have been specifically prepared for 108 Midland Avenue. They are not suitable for use on other projects or in other locations without the approval and participation of the architect. Reproduction prohibited without approval of the architect. 2023 Haynes Residence 108 Midland Avenue Aspen, CO 81611 PROJECT SITE COUNCIL 1/30/2023 Haynes Residence 108 Midland Avenue, Aspen, CO PROJECT DIRECTORY Oddo Engineering (STRUCTURAL ENGINEER) 713 Cooper Avenue CONTACT: Robert Oddo Glenwood Springs, CO 81601 (970) 945-1006 bob@oddogws.com Red Room Design (ARCHITECT OF RECORD) 1001 Grand Ave, Suite 103 CONTACT: Steven May Glenwood Springs, CO 81601 (970) 413-3144 stevenm@redroom-design.com Midland Properties LLC (OWNER) 808 N 5th Street CONTACT: Justin Haynes Alpine, TX 79830 Giant Properties (CONTRACTOR) PO Box 2652 CONTACT: Judd Clarence Aspen, CO 81612 (970) 688-1804 judd@giantpropertiesinc.com Aspen Survey (SURVEY) 210 S Galena Street #22 CONTACT: Michael Lafferty Aspen, CO 81611 (970) 925-3816 surveyor@email.com Escape Garden Design (LANDSCAPE) 312-E AABC CONTACT: Jennifer Dolecki-Smith Aspen, CO 81611 (970) 920-3700 jennifer@escapegardendesign.com Kumar + Associates (GEOTECHNICAL ENGINEER) 5020 County Road 154 CONTACT: Dan Hardin Glenwood Springs, CO 81801 (970) 945-7988 kaglenwood@kumarusa.com Crystal River Civil (CIVIL ENGINEER) 1101 Village Road UL-4C CONTACT: Jay Engstrom Carbondale, CO 81623 (970) 404-1144 jay@crystalrivercivil.com Bendon Adams (PLANNER) 300 S Spring Street #202 CONTACT: Sara Adams Aspen, CO 81611 (970) 925-2855 sara@bendonadams.com Andersson/Wise (ARCHITECT OF DESIGN) 807 Brazos Street Suite 800 CONTACT: Ryan Oliason Austin, TX 78701 (512) 866-3523 ryan@anderssonwise.com The Renner Project (INTERIOR DESIGNER) 30118 N Lamar Boulevard CONTACT: Kimberly Renner Austin, TX 78705 (512) 917-4211 ktr@therennerproject.com Brema Engineering (MECHANICAL) 783 Second Street CONTACT: Brent Wilson Aspen CO81631 (970) 390-7673 brent@bremaengr.com PROJECT INFO JURISDICTION: City of Aspen PARCEL ID : 273718126110 LEGAL DESC: SUBDIVISION: Ferguson Exemption - LOT: 1 2015 INTERNATIONAL RESIDENTIAL CODE (IRC) 2015 INTERNATIONAL ENERGY CONSERVATION CODE (IECC) Zoning: R-15A District Climate Zone: 7 Height Limit: 25'-0" Page 23 of 110 57214 COVER.2 COVER SHEET NOT FOR CONSTRUCTION 1/30/2023COUNCIL + ANDERSSON / WISE 807 Brazos St #800 Austin TX 78701 RED 1001 Grand Ave #103 Glenwood Springs CO 81601 © These documents have been specifically prepared for 108 Midland Avenue. They are not suitable for use on other projects or in other locations without the approval and participation of the architect. Reproduction prohibited without approval of the architect. 2023 Haynes Residence 108 Midland Avenue Aspen, CO 81611 D101 A R1 I301 1 3 24 A401 101 1 A301 1 A401 1 ENTRY 101 ZONE MATCH LINEMATCH GRID ELEVATION SECTION DETAIL SECTION INTERIOR ELEVATION SPOT DOOR WINDOW W1 ASSEMBLY DETAIL CALLOUTA601 1 DRAWING REVISION SYMBOL LEGEND DRAWING INDEXMATERIAL LEGEND CONCRETE MDF EARTH SHEATHING GLASS STEEL GRAVEL STONE GWB WOOD INSULATION A AAD ATTIC ACCESS DOOR AB ANCHOR BOLT ACOUS ACOUSTICAL ACP ACOUSTIC CEILNG PANEL ACT ACOUSTIC CEILING TILE AD AREA DRAIN, ACCESS DOOR ADD ADDENDUM ADD'N ADDITION, ADDITIONAL ADJ ADJUSTABLE AFF ABOVE FINISH FLOOR AGGR AGGREGATE ALT ALTERNATE ALUM ALUMINUM ANCH ANCHOR ANOD ANODIZED AOR AREA OF REFUGE AP ACCESS PANEL APPROX APPROXIMATELY ARCH ARCHITECT, ARCHITECTURAL ASPH ASPHALT ASS'T ASSITANT ASS'Y ASSEMBLY AT ASH TRAY AUTO AUTOMATIC AUX AUXILIARY B BPL BASE PLATE BF BARRIER FREE BM BENCHMARK BOS BOTTOM OF SLAB BUR BUILT-UP ROOFING BD BOARD BEV BEVELED BITUM BITUMINOUS BKR BD BACKER BOARD BLDG BUILDING BLK'G BLOCKING BLK BLOCK BM BEAM BO BOTTOM OF BOTT BOTTOM BR'G BEARING BSM'T BASEMENT BS BOTH SIDES BSPL BACKSPLASH BTW BETWEEN C CB CATCH BASIN CC CENTER TO CENTER C HT CEILING HEIGHT CI CAST IRON CIP CAST-IN-PLACE CJ CONTROL JOINT CL CENTER LINE CMU CONCRETE MASONRY UNIT CO CLEAN OUT CP CEMENT PLASTER CT CERAMIC TILE CW COLD WATER CAB CABINET CDR CEDAR CEM CEMENT, CEMENTITIOUS CER CERAMIC CH CHANNEL CLG CEILING CLO CLOSET CLOS CLOSURE CLR CLEAR CNTR COUNTER COL COLUMN COMP COMPOSITE, COMPACTED CONC CONCRETE CONF CONFERENCE CONN CONNECT, CONNECTION CONSTR CONSTRUCTION CONT CONTINUOUS CONTR CONTRACTOR CORR CORRIDOR, CORRUGATED CPT CARPET CTR CENTER CTSK COUNTERSUNK D D DRYER DF DRINKING FOUNTAIN DL DEAD LOAD DO DOOR OPENING DP DAMPPROOFING DS DOWNSPOUT DSP DRY SRANDPIPE DW DISHWASHER DBL DOUBLE DEMO DEMOLITION, DEMOLISH DEPT DEPARTMENT DET DETAIL DIA DIAMETER DIFF DIFFERENCE, DIFFUSER DIM DIMENSION DIR DIRECTION, DIRECTORY DISP DISPENSER DISPO DISPOSAL DN DOWN DO DITTO DR DOOR DWG DRAWING DWR DRAWER ABBREVIATIONS E E EAST EF EXHAUST FAN EJ EXPANSION JOINT EO ELECTRICAL OUTLET EP ELEXTRICAL PANELBOARD ES EXIT SIGN EW EACH WAY EWC ELECTRICAL WATER COOLER EA EACH EL ELEVATION ELAS WP ELASTOMETRIC WATERPROOFING ELEC ELECTRIC, ELECTRICAL ELEV ELEVATOR ELIM ELIMINATE EMER EMERGENCY ENAM ENAMEL ENCL ENCLOSURE ENVIR ENVIRONMENT EQ EQUAL EQPT EQUIPMENT EXC EXCAVATED EXP EXPANSION EXP B EXPANSION BOLT EXPO EXPOSED EXST EXISTING EXT EXTERIOR F FA FIRE ALARM FB FLAT BAR FD FLOOR DRAIN FE FIRE EXTINGUISHER FEC FIRE EXTINGUISHER CABINET FF FINISHED FLOOR FH FIRE HYDRANT, FRAME WIDTH FHC FIRE HYDRANT CABINET FO FINISHED OPENING FOC FACE OF CONCRETE FOF FACE OF FINISH FOIC FURNISHED BY OWNER, INSTALLED BY CONTRACTOR FOM FACE OF MASONRY FP FLOOR PLAN FS FULL SIZE FSS FLOOR SERVICE SINK FAB FABRIC FAST FASTENER FDN FOUNDATION FIN FINISH FIXT FIXTURE FLASH FLASHING FLR FLOOR FRPF FIREPROOF FT FEET, FOOT FTG FOOTING FURN FURNISH, FURNISHED FURR FURRING FUT FUTURE G G GAS GC GENERAL CONTRACTOR GC GYPSUM CONCRETE GFI GROUNF FAULT INTERRUPTOR GFRC GLASS FIBER REINFORCED CONCRETE GFRG GROUND FAULT REINFORCED GYPSUM GR GUARD RAIL GSM GALVANIZED SHEET METAL GWB GYPSUM WALL BOARD GA GAUGE GALV GALVANIZED GEN GENERAL GL GLASS GND GROUND GR GRADE GYP GYPSUM H HB HOSE BIB HC HOLLOW CORE HCWD HOLLOW CORE WOOD DOOR HM HOLLOW METAL HP HIGH POINT HVAC HEATING, VENTILATION, AIR CONDITIONING HW HOT WATER HWH HOT WATER HEATER HC HANDICAPPED HD HEAD HDWD HARDWOOD HDWR HARDWARE HGR HANGER HGT HEIGHT HORIZ HORIZONTAL HR HANDRAIL HR HOUR HYD HYDRANT I ID INSIDE DIAMETER (DIM) IN or INCH OR INCHES INFO INFORMATION INSUL INSULATION OR INSULATED INT INTERIOR J JAN JANITOR JST JOIST JT JOINT K KOP KNOCK-OUT PANEL KIT KITCHEN L LH LEFT HAND LL LIVELOAD LP LOW POINT LS LIGHT SWITCH LAM LAMINATE LAV LAVATORY LKR LOCKER LT LIGHT LT WT LIGHTWEIGHT M MC MEDICINE CABINET MO MASONTRY OPENING MACH MACHINE MARB MARBLE MAS MASONRY MATL MATERIAL MAX MAXIMUM MECH MECHANICAL MED MEDIUM MED CAB MEDICINE CABINET MEMB MEMBRANE MET/MTL METAL OR METALIC MEZZ MEZZANINE MFR MANUFACTURER MH MANHOLE MICR MICROWAVE OVEN MIN MINIMUM MIR MIRROR MISC MISCELLANEOUS MTD MOUNTED MUL MULLION N N NORTH NIC NOT IN CONTRAST NTS NOT TO SCALE NO NUMBER NOM NOMINAL O OA OVERALL OC ON CENTER OD OUTSIDE DIAMETER (DIM) OH OPPOSITE HAND OH OVERHEAD OP ORIGIN POINT OBS OBSCURE OFF OFFICE OPN'G OPENING OPP OPPOSITE P LBS POUNDS P LAM PLASTIC LAMINATE PC PRE-CAST PH PANIC HARDWARE PS PROJECTION SCREEN PSF POUNDS PER SQUARE FOOT PSL PARALLEL STRAND LUMBER PT PLATE PVC POLYVINYL CHLORIDE PERF PERFORATED PERIM PERIMETER PL PLATE PLAS PLASTER PLYWD PLYWOOD PNL PANEL PR PAIR PROP PROPERTY PT POINT PTD PAINTED PTN PARTITION PVM'T PAVEMENT PWR POWER Q QT QUARRY TILE R R RISER RD ROOF DRAIN RDO ROOF DRAIN OVERFLOW RO ROUGH OPENING RAD RADIUS REF REFERENCE REFL REFLECTED REFR REFRIGERATOR REINF REINFORCED REQ'D REQUIRED RESIL RESILIENT RET RETAINING REV REVISED, REVISION RF'G ROOFING RGTR REGISTER RM ROOM RND ROUND RWD REDWOOD S S SOUTH OR SINK SC SOLID CARE SD SMOKE DETECTOR SDISP SOAP DISPENSER SF SQUARE FEET (FOOT) SJ SEALANT JOINT SAN SANITARY SCHED SCHEDULE SCR SCUPPER SECT SECTION SG SAFETY GLASS SH SHELF SHR SHOWER SHT'G SHEATHING SHT SHEET SIM SIMILAR SL SLOPE SL TD SLOPE TO DRAIN SLNT SEALANT SNGL SINGLE SP SPRINKLER SPEC SPECIFICATION SPK'R SPEAKER SQ SQUARE SST STAINLESS STEEL ST'D STANDARD STA STATION STAG'D STAGED STD STAINED STL STEEL STOR STORAGE STRUC STRUCTURAL SURF SURFACE SUSP SUSPENDED SYM SYMMETRICAL SYMBOL # POUND, NUMBER & AND @ AT L ANGLE T T TREAD T&G TONGUE & GROOVE T'HLD THRESHOLD TB TOWEL BAR TBD TO BE DETERMINED TC TRASH COMPACTOR TOC TOP OF CONCRETE TOP TOP OF PLATE TOS TOP OF STEEL TOW TOP OF WALL TP TOP OF PAVEMENT TPH TOILET PAPER HOLDER TV TELEVISION TEL TELEVISION TEMP TEMPATURE TEMP GL TEMPERED GLASS THK THICK TRTD TREATED TYP TYPICAL U UL UNDERWRITER'S LABORATIES, INC UON UNLESS OTHERWISE NOTED UNF UNFINISHED UR URINAL V V VOLT VCT VINYL COMPOSITION TILE VIF VERIFY IN FIELD VP VENEER PLASTER VAR VARIES VERT VERTICAL VEST VESTIBULE W W WEST, WEATHER WC WATER CLOSET W GRO WINDOW GROUPING WH WATER HEATER WR WATER RESISTANT WWM WELDED MESH WIRE W/ WITH W/O WITHOUT WD WOOD WDE WINDOW WP WATERPROOF(ING) WSCT WAINSCOT WT WEIGHT Y YD YARD Z0.05 Z0.06 Z0.07 Z0.08 Z0.09 Z0.10 SURVEY SUBGRADE CALCULATIONS FAR CALCULATIONS NET LIVABLE CALCULATIONS MITIGATION CALCULATIONS GROSS FIRE AREA GENERAL COVER.1 COVER.2 COVER SHEET COVER SHEET PLANS Z0.13 Z0.13 Z0.14 Z0.15 HEIGHT OVER TOPOGRAPHY HEIGHT ELEVATIONS - MH HEIGHT ELEVATIONS - OFFICE 15' BASEMENT PLAN ELEVATIONS A0.02 A0.03 A0.04 A0.05 A0.06 A0.07 A0.08 A2.01 A2.02 A2.03 A2.04 A2.05 A2.06 PROPOSED SITE AND EXTERIOR LIGHTING PLAN MH- BASEMENT PLAN MH - FIRST FLOOR PLAN MH - SECOND FLOOR PLAN MH - ROOF PLAN OFFICE - PLANS TRASH ENCLOSURE - PLANS MH - EXTERIOR ELEVATIONS MH - EXTERIOR ELEVATIONS MH - EXTERIOR ELEVATIONS MH - EXTERIOR ELEVATIONS OFFICE - EXTERIOR ELEVATIONS TRASH ENCLOSURE - EXTERIOR ELEVATIONS ZONING Page 24 of 110 58215 59216 Z0.06 SUBGRADE CALCULATIONS NOT FOR CONSTRUCTION 1/30/2023COUNCIL + ANDERSSON / WISE 807 Brazos St #800 Austin TX 78701 RED 1001 Grand Ave #103 Glenwood Springs CO 81601 © These documents have been specifically prepared for 108 Midland Avenue. They are not suitable for use on other projects or in other locations without the approval and participation of the architect. Reproduction prohibited without approval of the architect. 2023 Haynes Residence 108 Midland Avenue Aspen, CO 81611 SUBGRADE EXPOSED AREA SUB-GRADE AREA9'-3 1/4"T.O. PLY - MAIN LEVEL B.O. STRUCT - SECOND LEVEL T.O. STRUCT. CONC. - GARAGE 39 sq ft 531 sq ft WW 29 sq ft WW 11 sq ft 35 sq ft 402 sq ft 7 sq ft WW 77 sq ft WW 28 sq ft 11'-0"10'-8 7/8"35'-9 5/8"34'-10 1/2"35'-9 5/8"11'-1 7/8"7'-8"10'-2"8'-8 1/2"9'-5 1/4"9'-3 1/4"73'-5 1/2"34'-10 1/2"17'-5 1/2" 2'-11 1/2" 18'-10"4'-0"11'-9 1/2"7'-7 1/2"14'-4 1/2"24'-2 1/2"5'-4 3/4"323 sq ft 162 sq ft681 sq ft 27 sq ft 37 sq ft 109 sq ft175 sq ft 233 sq ft 273 sq ft 329 sq ft 432 sq ft 81 sq ft511 sq ft 22 sq ft 406 sq ft 329 sq ft 371 sq ft 81 sq ft T.O. STRUCT. CONC. - BASEMENT LEVEL B.O. STRUCT - FIRST LEVEL T.O. PLY - MAIN LEVEL B.O. STRUCT - SECOND LEVEL 1 2 3 4 5 6 B.O. STRUCT - GARAGE 9 10 11 12 13 14 15 16 17 18 T.O. STRUCT. CONC. - CRAWL PROPOSED GRADE T.O. STRUCT. CONC. - GARAGE EXISTING GRADE CRAWLCRAWLCRAWL 39 sq ft22 sq ft SUBGRADE WALL AREA LOWER LEVEL WALL TOTAL WALL AREA (SF) EXPOSED WALL AREA (SF) UNEXPOSED WALL AREA (SF) 1 511 105 406 2 329 0 329 3 432 61 371 4 22 0 22 5 39 0 39 6 81 0 81 OVERALL TOTAL WALL AREA (SF)1,414 EXPOSED WALL AREA (SF)166 % OF EXPOSED WALL (EXPOSED/ TOTAL)11.74% UNEXPOSED WALL AREA (SF) 1248 % OF UNEXPOSED WALL (UNEXPOSED/ TOTAL)88.26% MAIN LEVEL WALL TOTAL WALL AREA (SF) EXPOSED WALL AREA (SF) UNEXPOSED WALL AREA (SF) 9 681 674 7 10 323 288 35 11 162 162 0 12 27 27 0 13 175 175 0 14 37 37 0 15 109 109 0 16 233 233 0 17 273 273 0 18 531 129 402 OVERALL TOTAL WALL AREA (SF)2,419 EXPOSED WALL AREA (SF)2,107 % OF EXPOSED WALL (EXPOSED/ TOTAL)87.10% UNEXPOSED WALL AREA (SF) 444 % OF UNEXPOSED WALL (UNEXPOSED/ TOTAL)18.35% OFFICE MAIN LEVEL WALL TOTAL WALL AREA (SF) EXPOSED WALL AREA (SF) UNEXPOSED WALL AREA (SF) 19 142 121 21 20 182 182 0 21 142 139 3 22 182 154 28 OVERALL TOTAL WALL AREA (SF)648 EXPOSED WALL AREA (SF)596 % OF EXPOSED WALL (EXPOSED/ TOTAL)91.98% UNEXPOSED WALL AREA (SF) 52 % OF UNEXPOSED WALL (UNEXPOSED/ TOTAL)8.02% SUBGRADE WALL AREALOWER LEVEL WALL TOTAL WALL AREA (SF) EXPOSED WALL AREA (SF) UNEXPOSED WALL AREA (SF)1 511 105 40623290329343261371422022539039681081OVERALL TOTAL WALL AREA (SF)1,414EXPOSED WALL AREA (SF)166% OF EXPOSED WALL (EXPOSED/ TOTAL)11.74%UNEXPOSED WALL AREA (SF) 1248 % OF UNEXPOSED WALL (UNEXPOSED/ TOTAL)88.26% MAIN LEVEL WALL TOTAL WALL AREA (SF) EXPOSED WALL AREA (SF) UNEXPOSED WALL AREA (SF) 9 681 674 7 10 323 288 35 11 162 162 0 12 27 27 0 13 175 175 0 14 37 37 0 15 109 109 0 16 233 233 0 17 273 273 0 18 531 129 402 OVERALL TOTAL WALL AREA (SF)2,419 EXPOSED WALL AREA (SF)2,107 % OF EXPOSED WALL (EXPOSED/ TOTAL)87.10% UNEXPOSED WALL AREA (SF) 444 % OF UNEXPOSED WALL (UNEXPOSED/ TOTAL)18.35% OFFICE MAIN LEVEL WALL TOTAL WALL AREA (SF) EXPOSED WALL AREA (SF) UNEXPOSED WALL AREA (SF) 19 142 121 21 20 182 182 0 21 142 139 3 22 182 154 28 OVERALL TOTAL WALL AREA (SF)648 EXPOSED WALL AREA (SF)596 % OF EXPOSED WALL (EXPOSED/ TOTAL)91.98% UNEXPOSED WALL AREA (SF) 52 % OF UNEXPOSED WALL (UNEXPOSED/ TOTAL)8.02% SUBGRADE WALL AREALOWER LEVEL WALL TOTAL WALL AREA (SF) EXPOSED WALL AREA (SF) UNEXPOSED WALL AREA (SF)1 511 105 40623290329343261371422022539039681081OVERALL TOTAL WALL AREA (SF)1,414EXPOSED WALL AREA (SF)166% OF EXPOSED WALL (EXPOSED/ TOTAL)11.74%UNEXPOSED WALL AREA (SF) 1248% OF UNEXPOSED WALL (UNEXPOSED/ TOTAL)88.26%MAIN LEVEL WALL TOTAL WALL AREA (SF) EXPOSED WALL AREA (SF) UNEXPOSED WALL AREA (SF)9 681 674 710323288351116216201227270131751750143737015109109016233233017273273018531129402OVERALL TOTAL WALL AREA (SF)2,419EXPOSED WALL AREA (SF)2,107% OF EXPOSED WALL (EXPOSED/ TOTAL)87.10%UNEXPOSED WALL AREA (SF) 444 % OF UNEXPOSED WALL (UNEXPOSED/ TOTAL)18.35% OFFICE MAIN LEVEL WALL TOTAL WALL AREA (SF) EXPOSED WALL AREA (SF) UNEXPOSED WALL AREA (SF) 19 142 121 21 20 182 182 0 21 142 139 3 22 182 154 28 OVERALL TOTAL WALL AREA (SF)648 EXPOSED WALL AREA (SF)596 % OF EXPOSED WALL (EXPOSED/ TOTAL)91.98% UNEXPOSED WALL AREA (SF) 52 % OF UNEXPOSED WALL (UNEXPOSED/ TOTAL)8.02% 531 sq ft 402 sq ft 34'-1"15'-10" 18 3 sq ft21 sq ft 14'-7"18'-7"14'-7"18'-7"9'-9 1/4"142 sq ft 182 sq ft 142 sq ft 182 sq ft 28 sq ftT.O. CONC - OFFICE B.O. STRUCT - OFFICE 19 20 21 22 SCALE: 1/8" = 1'-0"1Subgrade Calculations 0 4'8'16' THESE PLANS ARE CONCEPTUAL IN NATURE. INDIVIDUAL BUILDING PLANS MAY VARY BUT WILL BE EVALUATED FOR COMPLIANCE WITH DESIGN STANDARDS CONTAINED WITHIN SECTION 26.575.020 OF THE CITY OF ASPEN MUNICIPAL CODE AT THE TIME OF SUBMITTING A BUILDING PERMIT APPLICATION. Page 26 of 110 60217 Z0.07 FAR CALCULATIONS NOT FOR CONSTRUCTION 1/30/2023COUNCIL + ANDERSSON / WISE 807 Brazos St #800 Austin TX 78701 RED 1001 Grand Ave #103 Glenwood Springs CO 81601 © These documents have been specifically prepared for 108 Midland Avenue. They are not suitable for use on other projects or in other locations without the approval and participation of the architect. Reproduction prohibited without approval of the architect. 2023 Haynes Residence 108 Midland Avenue Aspen, CO 81611 FAR FLOOR AREA GARAGE DECK EXEMPT BUILT INPLANTER DECK AREAS (Land Use Code, 26.575.020.4) THE CALCULATION OF FLOOR AREAS SHALL NOT INCLUDE DECKS OR EXTERIOR STAIRWAYS UNLESS THE AREA OF THESE FEATURES IS GREATER THAN 15% OF THE ALLOWABLE FLOOR AREA FOR THE PROPERTY. IF THE AREA OF THSES FEATURES EXCEEDS 15% OF THE PROPERTY'S ALLOWABLE FLOOR AREA, ONLY THE AREAS IN EXCESS OF 15% SHALL BE ATTRIBUTED TOWARDS THE ALLOWABLE FLOOR AREA. GARAGE EXEMPTION (Land Use Code, 26.575.020-2) IN ZONE DISTRICTS OTHER THAN THE R-15B ZONE DISTRICT, PROPERTIES CONTAINING SOLELY A SINGLE -FAMILY, TWO (2) SINGLE FAMILY RESIDENCES , OR A DUPLEX , THE GARAGE AND CARPORT AREA SHALL BE EXCLUDED FROM THE CALCULATION OF FLOOR AREA AS FOLLOWS : Table 26.575.020-2 SIZE OF GARAGE AREA EXCLUDED PER PRIMARY DWELLING UNIT (NOT INCLUDING OR CARPORT ACCESSORY DWELLING UNITS OR CARRIAGE HOUSES) FIRST 0-250 SF 100% OF THE AREA NEXT 251-500 SF 50% OF THE AREA AREAS ABOVE 500 SF NO AREA EXCLUDED PATIO AREAS (Land Use Code, 26.575.020.6) PATIOS DEVELOPED AT OR WITHIN 6 INCHES OF FINISHED GRADE SHALL NOT BE COUNTED TOWARDS FLOOR AREA. WHEN ROOF OVERHANDS OR SIMILAR ARCHITECTURAL PROJECTIONS EXCEED 4 FEET, THE ENTIRE COUNTS TOWARDS FLOOR AREA. FLOOR AREA RATIO (Land Use Code) THE TOTAL FLOOR AREA OF ALL STRUCTURES ON A LOT DIVIDED BY THE LOT AREA. FLOOR AREA (Land Use Code) THE SUM TOTAL OF THE GROSS HORIZONTAL AREAS OF EACH STORY OF THE BUILDING MEASURED FROM THE EXTERIOR WALLS OF THE BUILDING. (SEE SUPPLEMENTARY REGULATIONS - SECTION 26.575.020, CALCULATIONS AND MEASUREMENTS STAIR AND ELEVATOR EXEMPTION (Land Use Code 26.575.020.D) WHEN CALCULATING VERTICAL CIRCULATION, THE CIRCULATION ELEMENT SHALL BE COUNTED AS FOLLOWS: A) FOR STAIRS AND ELEVATORS , THE AREA OF THE FEATURE SHALL BE PROJECTED DOWN AND COUNTED ON THE LOWEROF THE TWO LEVELS CONNECTED BY THE ELEMENT AND NOT COUNTED AS FLOOR AREA ON THE TOP-MOST INTERIOR FLOOR SERVED BY THE ELEMENT. MINIMUM NET LOT AREA PER DWELLING UNIT (SQUARE FEET) ( Land Use Code 26.710.060) A) DETACHED RESIDENTIAL DWELLING: FIFTEEN THOUSAND (15,000). FOR HISTORIC LANDMARK PROPOERTIES: THREE THOUSAND (3000) B) DUPLEX: SEVEN THOUSAND, FIVE HUNDRED (7,500). FOR HISTORIC LANDMARK PROPOERTIES: THREE THOUSAND (3000) C) BED AND BREAKFAST, BOARDINGHOUSE: NO REQUIREMENT FLOOR AREA (Land Use Code) THE SUM TOTAL OF THE GROSS HORIZONTAL AREAS OF EACH STORY OF THE BUILDING MEASURED FROM THE EXTERIOR WALLS OF THE BUILDING. (SEE SUPPLEMENTARY REGULATIONS - SECTION 26.575.020, CALCULATIONS AND MEASUREMENTS MINIMUM NET LOT AREA PER DWELLING UNIT (SQUARE FEET) ( Land Use Code 26.710.060) A) DETACHED RESIDENTIAL DWELLING: FIFTEEN THOUSAND (15,000). FOR HISTORIC LANDMARK PROPOERTIES: THREE THOUSAND (3000) B) DUPLEX: SEVEN THOUSAND, FIVE HUNDRED (7,500). FOR HISTORIC LANDMARK PROPOERTIES: THREE THOUSAND (3000) C) BED AND BREAKFAST, BOARDINGHOUSE: NO REQUIREMENT NUPUPUPUP1 1 3 3 4 4 5 5 7 7 8 8 9 9 F E D C B A 2 2 6 6 8'-8 1/2"17'-7"4'-9"5'-5" 35'-9 5/8"11'-1 7/8"34'-10 1/2"7'-8"35'-9 5/8"10'-8 7/8"11'-0" 1 3 2 4 5 6 MECH <5'-6" BASEMENT 2,048 sq ft MECH <5'-6" G G J J 1112 10 H H I I 14'-7"18'-7" 18'-7"14'-7"UNCOVERED OUTDOOR MECH ENCLOSURE 19 20 21 22 OFFICE 271 sq ft DOWNDOWNUP 1 1 3 3 4 4 5 5 7 7 8 8 9 9 2 2 6 6 GARAGE 250 sq ft @ 50% GARAGE NON-EXEMPT 245 sq ft GARAGE EXEMPTION 250 sq ft 24'-2 1/2"34'-10 1/2"17'-5 1/2" LINE OF WINDOW WELL BELOW LINE OF WINDOW WELL BELOW LINE OF WINDOW WELL BELOW LINE OF WINDOW WELL BELOW ELEVSTAIR 73'-5 1/2"2'-11 1/2"18'-10"4'-0"11'-9 1/2"14'-4 1/2"7'-7 1/2"34'-1"15'-10"9 11 10 12 18 13 14 15 14 16 17 10 FIRST LEVEL 2,062 sq ft LINE OF OVERHANG ABOVEDOWN1 1 3 3 4 4 5 5 7 7 8 8 9 9 2 2 6 610'-3 1/2"OVERHANG.EXEMPT DECK 826 sq ft SECOND LEVEL 1,599 sq ft LINE OF OVERHANG ABOVE PLANTER PLANTERPLANTERTRASH 57 sq ft FLOOR AREA BASEMENT AREA (2,048 x 11.74%) 240.4352 FIRST FLOOR AREA (2,119 x 87.10%) 1,845.65 GARAGE LEVEL (250 SF EXEMPT) 250 GARAGE LEVEL (250 x 50%)125 GARAGE LEVEL ( NOT EXEMPT 245 SF x 87.10%)213.395 SECOND FLOOR AREA 1,599 OFFICE AREA (271 x 91.98%)249.2658 TOTAL FLOOR AREA 4522.745 4,522.745 - 250 = 4,272.75 SF SECOND FLOOR DECK 826 TOTAL DECK 826 ALLOWABLE EXEMPT DECK 635.78 TOTAL DECK FLOOR AREA 826 - 635.78 = 190.22 SF TOTAL FLOOR AREA 4,272.75 + 190.22 4,462.97 SF PURCHASE OF TDR ALLOWS FOR 250 SF 4,238.5 SF + 250 TDR = 4,488.6 SF 4,462.97 - 4,488.6 -25.63 OUR PROPOSED DESIGN IS 25.63 SF UNDER THE ALLOWABLE AREA WITH PURCHASE OF TDR ALLOWABLE FLOOR AREA 4,080 SF OF FLOOR AREA, PLUS 7 SF PER EACH ADD'L 100 SF 11,264.25 - 9,000 = 2,264.25 2,264.25/ 100 = 22.64 22.64*7 = 158.5 SF 4, 080 SF + 158.5 SF = 4,238.5 SF TOTAL ALLOWABLE AREA 4238.5 SF ALLOWABLE EXEMPT DECK 4238.5 x 15% = 635.78 NET LOT AREA ZONE DISTRICT REQUIREMENTS REFERENCE MIN. GROSS LOT AREA (PER R-15A)15, 000 SF 26.710.060 MIN. NET LOT AREA (PER R-15A)15, 000 SF 26.710.060 LOT SIZE PER SURVEY 15,019.00 REFERENCE REDUCTIONS FOR AREA WITH SLOPES 0%-20% (100% OF PARCEL AREA TO BE INCLUDED IN THE NET LOT AREA)15,019 x 25%SURVEY 26.575.020-1 TOTAL AREA REDUCTIONS 15,019 - 3754.75 NET LOT AREA 11,264.25 SF SCALE: 1/8" = 1'-0"1Basement FAR 0 4'8'16'SCALE: 1/8" = 1'-0"3Second Floor FAR 0 4'8'16'SCALE: 1/8" = 1'-0"2First Floor FAR 0 4'8'16' THESE PLANS ARE CONCEPTUAL IN NATURE. INDIVIDUAL BUILDING PLANS MAY VARY BUT WILL BE EVALUATED FOR COMPLIANCE WITH DESIGN STANDARDS CONTAINED WITHIN SECTION 26.575.020 OF THE CITY OF ASPEN MUNICIPAL CODE AT THE TIME OF SUBMITTING A BUILDING PERMIT APPLICATION. Page 27 of 110 61218 Z0.08 NET LIVABLE CALCULATIONS NOT FOR CONSTRUCTION 1/30/2023COUNCIL + ANDERSSON / WISE 807 Brazos St #800 Austin TX 78701 RED 1001 Grand Ave #103 Glenwood Springs CO 81601 © These documents have been specifically prepared for 108 Midland Avenue. They are not suitable for use on other projects or in other locations without the approval and participation of the architect. Reproduction prohibited without approval of the architect. 2023 Haynes Residence 108 Midland Avenue Aspen, CO 81611 NET LIVABLE AREA NET LIVABLE AREA NET LIVEABLE AREA THE AREAS WITHIN A BUILDING DESIGNED TO BE USED FOR HABITATIONAND HUMAN ACTIVITY NDOWNDOWNUP 1 1 3 3 4 4 5 5 7 7 8 8 9 9 1112 2 2 6 6 LINE OF WINDOW WELL BELOW LINE OF WINDOW WELL BELOW LINE OF WINDOW WELL BELOW LINE OF WINDOW WELL BELOW FIRST LEVEL 2,603 sq ft LINE OF OVERHANG ABOVEDOWN1 1 3 3 4 4 5 5 7 7 8 8 9 9 1112 2 2 6 6 PLANTER PLANTERPLANTERSECOND LEVEL 1,563 sq ft LINE OF OVERHANG ABOVE PLANTER PLANTERPLANTERUPUPUPUP1 1 3 3 4 4 5 5 7 7 8 8 9 9 F E D C B G 1112 10 A 2 2 6 6 BASEMENT 1,794 sq ft NET LIVEABLE AREA BASEMENT AREA 1,794 FIRST FLOOR AREA 2,603 SECOND FLOOR AREA 1,563 OFFICE AREA 234 TOTAL NET LIVEABLE AREA 6,194 13457 G G J J 1112 10 2 H H I I 6 OFFICE 234 sq ft SCALE: 1/8" = 1'-0"2First Floor Net liveable 0 4'8'16'SCALE: 1/8" = 1'-0"3Second Floor Net Liveable 0 4'8'16'SCALE: 1/8" = 1'-0"1Basement Net Liveable 0 4'8'16' THESE PLANS ARE CONCEPTUAL IN NATURE. INDIVIDUAL BUILDING PLANS MAY VARY BUT WILL BE EVALUATED FOR COMPLIANCE WITH DESIGN STANDARDS CONTAINED WITHIN SECTION 26.575.020 OF THE CITY OF ASPEN MUNICIPAL CODE AT THE TIME OF SUBMITTING A BUILDING PERMIT APPLICATION. Page 28 of 110 62219 Z0.09 MITIGATION CALCULATIONS NOT FOR CONSTRUCTION 1/30/2023COUNCIL + ANDERSSON / WISE 807 Brazos St #800 Austin TX 78701 RED 1001 Grand Ave #103 Glenwood Springs CO 81601 © These documents have been specifically prepared for 108 Midland Avenue. They are not suitable for use on other projects or in other locations without the approval and participation of the architect. Reproduction prohibited without approval of the architect. 2023 Haynes Residence 108 Midland Avenue Aspen, CO 81611 MITIGATION AREA MITIGATION AREA FLOOR AREA MITIGATION DEFINITION (Land Use Code, 26.575.020-2) FLOOR AREA SHALL BE ATTRIBUTED TO THE LOT OR PARCEL UPON WHICH IT IS DEVELOPED . IN MEASUREING A BUILDING FOR THE PURPOSES OF CALCULATING FLOOR AREAS, THERE SHALL BE INCLUDED ALL AREAS WITHIN THE SURROUNDING EXTERIOR WALLS OF THE BUILDING. WHEN MEASURING FROM THE EXTERIOR WALLS, THE MEASUREMENT SHALL BE TAKEN FROM THE EXTERIOR FACE OF FRAMING, EXTERIOR FACE OF STRUCTURAL BLOCK, EXTERIOR FACE OF STRAW BALE, OR SIMILAR EXTERIOR SURFACE OF THE NOMINAL STRUCTURE EXCLUDING SHEATHING, VAPOR BARRIER , WEATHERPROOFING MEMBRANE, EXTERIOR-MOUNTED INSULATION SYSTEMS, AND EXCLUDING ALL EXTERIOR VENEER AND SURFACE TREATMENTS SUCH AS STONE, STUCCO, BRICKS, SHINGLES, CLAPBOARDS, OR OTHER SIMILAR EXTERIOR VENEER TREATMENTS. Table 26.575.020-2 SIZE OF GARAGE AREA EXCLUDED PER PRIMARY DWELLING UNIT OR CARPORT (NOT INCLUDING ACCESSORY DWELLING UNITS OR CARRIAGE HOUSES) FIRST 0-250 SF 100% OF THE AREA NEXT 251-500 SF 50% OF THE AREA AREAS ABOVE 500 SF NO AREA EXCLUDED NDOWN FIRST FLOOR 2,748 sq ftDOWNUP 1 1 3 3 4 4 5 5 7 7 8 8 9 9 1112 2 2 6 6 LINE OF WINDOW WELL BELOW LINE OF WINDOW WELL BELOW LINE OF WINDOW WELL BELOW LINE OF WINDOW WELL BELOW LINE OF OVERHANG ABOVE 13457 G G J J 1112 10 2 H H I I 6 OFFICE 271 sq ft BASEMENT 2,396 sq ft UPUPUPUP1 1 3 3 4 4 5 5 7 7 8 8 9 9 F E D C B 1112 10 A 2 2 6 6DOWN1 1 3 3 4 4 5 5 7 7 8 8 9 9 1112 2 2 6 6 SECOND LEVEL 1,739 sq ft LINE OF OVERHANG ABOVE MITIGATION TOTAL BASEMENT AREA 2,048 FIRST FLOOR AREA 2,804 FIRST FLOOR OFFICE AREA 271 SECOND FLOOR AREA 1,739 6,862 SCALE: 1/8" = 1'-0"2First Floor Mitigation 0 4'8'16'SCALE: 1/8" = 1'-0"1Basement Mitigation 0 4'8'16'SCALE: 1/8" = 1'-0"3Second Floor Mitigation 0 4'8'16' THESE PLANS ARE CONCEPTUAL IN NATURE. INDIVIDUAL BUILDING PLANS MAY VARY BUT WILL BE EVALUATED FOR COMPLIANCE WITH DESIGN STANDARDS CONTAINED WITHIN SECTION 26.575.020 OF THE CITY OF ASPEN MUNICIPAL CODE AT THE TIME OF SUBMITTING A BUILDING PERMIT APPLICATION. Page 29 of 110 63220 Z0.10 GROSS FIRE AREA NOT FOR CONSTRUCTION 1/30/2023COUNCIL + ANDERSSON / WISE 807 Brazos St #800 Austin TX 78701 RED 1001 Grand Ave #103 Glenwood Springs CO 81601 © These documents have been specifically prepared for 108 Midland Avenue. They are not suitable for use on other projects or in other locations without the approval and participation of the architect. Reproduction prohibited without approval of the architect. 2023 Haynes Residence 108 Midland Avenue Aspen, CO 81611 FIRE AREA THE AGGREGATE FLOOR AREA ENCLOSED AND BOUNDED BY FIRE WALLS, EXTERIOR WALLS, OR FIRE-RESITANCE RATED HORIZONTAL ASSEMBLIES OF A BUILDING . AREAS OF THE BUILDING NOT PROVIDED WITH SURROUNDING WALLS SHALL BE INCLUDED IN THE FIRE AREA IF SUCH AREAS ARE INCLUDED WITHIN THE HORIZONTAL PROJECTION OF THE ROOF OR FLOOR ABOVE. GROSS AREA GROSS AREA COVEREDOUTDOOR AREA UPUPUPUP1 1 3 3 4 4 5 5 7 7 8 8 9 9 F E D C B 1112 10 A 2 2 6 6 BASEMENT 2,076 sq ft DOWNDOWNUP 1 1 3 3 4 4 5 5 7 7 8 8 9 9 1112 2 2 6 6 LINE OF WINDOW WELL BELOW LINE OF WINDOW WELL BELOW LINE OF WINDOW WELL BELOW LINE OF WINDOW WELL BELOW FIRST LEVEL 2,747 sq ft COVERED AREA 42 sq ft LINE OF OVERHANG ABOVEDOWN1 1 3 3 4 4 5 5 7 7 8 8 9 9 1112 2 2 6 6 SECOND LEVEL 1,673 sq ft COVERED AREA 123 sq ft LINE OF OVERHANG ABOVE GROSS FIRE AREA TOTAL BASEMENT AREA 2,076 FIRST FLOOR AREA 2,747 FIRST FLOOR OFFICE AREA 271 SECOND FLOOR AREA 1,673 COVERED EXTERIOR AREA 165 6,932 13457 G G J J 1112 10 2 H H I I 6 OFFICE 271 sq ft SCALE: 1/8" = 1'-0"1Gross Area Basement Plan 0 4'8'16'SCALE: 1/8" = 1'-0"2Gross Area First Floor Plan 0 4'8'16'SCALE: 1/8" = 1'-0"3Gross Area Second Floor Plan 0 4'8'16' THESE PLANS ARE CONCEPTUAL IN NATURE. INDIVIDUAL BUILDING PLANS MAY VARY BUT WILL BE EVALUATED FOR COMPLIANCE WITH DESIGN STANDARDS CONTAINED WITHIN SECTION 26.575.020 OF THE CITY OF ASPEN MUNICIPAL CODE AT THE TIME OF SUBMITTING A BUILDING PERMIT APPLICATION. Page 30 of 110 64221 Z0.13 HEIGHT OVER TOPOGRAPHY NOT FOR CONSTRUCTION 1/30/2023COUNCIL + ANDERSSON / WISE 807 Brazos St #800 Austin TX 78701 RED 1001 Grand Ave #103 Glenwood Springs CO 81601 © These documents have been specifically prepared for 108 Midland Avenue. They are not suitable for use on other projects or in other locations without the approval and participation of the architect. Reproduction prohibited without approval of the architect. 2023 Haynes Residence 108 Midland Avenue Aspen, CO 81611 HEIGHT OVER TOPOGRAPHY HEIGHTS ARE MEASURED TO THE MOST RESTRICTIVE GRADE. 100'-0" = 7974'-11 1 /4" DEFINITIONS (SECTION 26.104.100) HEIGHT, BUILDING THE HEIGHT OF A BUILDING SHALL BE THE MAXIMUM DISTANCE POSSIBLE MEASURED VERTICALLY FROM NATURAL GRADE AT ANY POINT WITHIN THE INTERIOR OF THE BUILDING; AND FROM NATURAL OR FINISHED GRADE (WHICHEVER IS LOWER) AT ANY POINT AROUND THE PERIMETER OF THE BUILDING TO THE HIGHEST POINT OR STRUCTURE WITHIN A VERICAL PLANE. (SEE SUPPLEMENARY REGULATIONS SECTION 26.575.020, MEASURMENT AND CALCULATIONS).10' 82 '- 8 3 /4 " A B LINE OF WALL FRAMING BELOW SIDE SETBACKREAR SETBA C K PROPE R T Y LI N E DECK BELOW MECH ENCLOSURE 797579 75 797 0 7970797579657960796579607 1/2:127 1/2:12DECK BELOW W A L K W A Y PATIO BELOW 1/4:121/4:121/4:121/4:12 1 2 A - ROOF LABEL ROOF HEIGHT ROOF HEIGHT - 7998'-3 1/8"23'-11 5/16" SITE EXISTING - 7980'-4 1/4" SITE PROPOSED (MOST RESTRICTVE) - 7975'-0" B - ROOF LABEL ROOF HEIGHT ROOF HEIGHT - 7998'-3 1/8"20'-3" SITE EXISTING - 7980'-11 1/4"" SITE PROPOSED (MOST RESTRICTVE) - 7978'-1/4" A - ROOF LABEL ROOF HEIGHTROOF HEIGHT - 7998'-3 1/8"23'-11 5/16" SITE EXISTING - 7980'-4 1/4" SITE PROPOSED (MOST RESTRICTVE) - 7975'-0" B - ROOF LABEL ROOF HEIGHT ROOF HEIGHT - 7998'-3 1/8"20'-3" SITE EXISTING - 7980'-11 1/4"" SITE PROPOSED (MOST RESTRICTVE) - 7978'-1/4" SCALE: 1/4" = 1'-0"1Height Over Topography 0 2'4'8' THESE PLANS ARE CONCEPTUAL IN NATURE. INDIVIDUAL BUILDING PLANS MAY VARY BUT WILL BE EVALUATED FOR COMPLIANCE WITH DESIGN STANDARDS CONTAINED WITHIN SECTION 26.575.020 OF THE CITY OF ASPEN MUNICIPAL CODE AT THE TIME OF SUBMITTING A BUILDING PERMIT APPLICATION. Page 31 of 110 65222 Z0.13 HEIGHT ELEVATIONS - MH NOT FOR CONSTRUCTION 1/30/2023COUNCIL + ANDERSSON / WISE 807 Brazos St #800 Austin TX 78701 RED 1001 Grand Ave #103 Glenwood Springs CO 81601 © These documents have been specifically prepared for 108 Midland Avenue. They are not suitable for use on other projects or in other locations without the approval and participation of the architect. Reproduction prohibited without approval of the architect. 2023 Haynes Residence 108 Midland Avenue Aspen, CO 81611 HEIGHT OVER TOPOGRAPHY HEIGHTS ARE MEASURED TO THE MOST RESTRICTIVE GRADE. 100'-0" = 7974'-11 1 /4" ROOF LABEL HEIGHT OVER TOPO ROOF HEIGHT A 7999'-5 7/8" ROOF HEIGHT 24'-10 1/2" 7980'-3 7/8" SITE EXISTING 7974'-7 3/8" SITE PROPOSED (MOST RESTRICTIVE) B 7999'-5 7/8" ROOF HEIGHT 24'-10 1/2" 7980'-10 5/8" SITE EXISTING 7974'-7 3/8" SITE PROPOSED (MOST RESTRICTIVE) C XXXX'-X" ROOF HEIGHT XX'-X" XXXX'-X" SITE EXISTING XX'-X" XXXX'-X" SITE PROPOSED (MOST RESTRICTIVE) XX'-X"" DEFINITIONS (SECTION 26.104.100) HEIGHT, BUILDING THE HEIGHT OF A BUILDING SHALL BE THE MAXIMUM DISTANCE POSSIBLE MEASURED VERTICALLY FROM NATURAL GRADE AT ANY POINT WITHIN THE INTERIOR OF THE BUILDING; AND FROM NATURAL OR FINISHED GRADE (WHICHEVER IS LOWER) AT ANY POINT AROUND THE PERIMETER OF THE BUILDING TO THE HIGHEST POINT OR STRUCTURE WITHIN A VERICAL PLANE. (SEE SUPPLEMENARY REGULATIONS SECTION 26.575.020, MEASURMENT AND CALCULATIONS). 1 3 4 5 7 8 926 25'-0"EXISTING GRADE PROPOSED GRADE B C D E FA 25'EXISTING GRADE PROPOSED GRADE 9 8 7 5 4 3 126 2'-6"25'-0"EXISTING GRADE PROPOS E D GRADE F E D C B A A B 25'-0"24'-10 1/2"24'-10 1/2"EXISTING GRADE PROPOSED GRADE SCALE: 1/8" = 1'-0"1MH - North Elevation 0 4'8'16'SCALE: 1/8" = 1'-0"2MH - East Elevation 0 4'8'16' SCALE: 1/8" = 1'-0"3MH - South Elevation 0 4'8'16'SCALE: 1/8" = 1'-0"4MH - West Elevation 0 4'8'16' THESE PLANS ARE CONCEPTUAL IN NATURE. INDIVIDUAL BUILDING PLANS MAY VARY BUT WILL BE EVALUATED FOR COMPLIANCE WITH DESIGN STANDARDS CONTAINED WITHIN SECTION 26.575.020 OF THE CITY OF ASPEN MUNICIPAL CODE AT THE TIME OF SUBMITTING A BUILDING PERMIT APPLICATION. Page 32 of 110 66223 Z0.14 HEIGHT ELEVATIONS - OFFICE NOT FOR CONSTRUCTION 1/30/2023COUNCIL + ANDERSSON / WISE 807 Brazos St #800 Austin TX 78701 RED 1001 Grand Ave #103 Glenwood Springs CO 81601 © These documents have been specifically prepared for 108 Midland Avenue. They are not suitable for use on other projects or in other locations without the approval and participation of the architect. Reproduction prohibited without approval of the architect. 2023 Haynes Residence 108 Midland Avenue Aspen, CO 81611 HEIGHT OVER TOPOGRAPHY HEIGHTS ARE MEASURED TO THE MOST RESTRICTIVE GRADE. 100'-0" = 7974'-11 1 /4" ROOF LABEL HEIGHT OVER TOPO ROOF HEIGHT A 7999'-5 7/8" ROOF HEIGHT 24'-10 1/2" 7980'-3 7/8" SITE EXISTING 7974'-7 3/8" SITE PROPOSED (MOST RESTRICTIVE) B 7999'-5 7/8" ROOF HEIGHT 24'-10 1/2" 7980'-10 5/8" SITE EXISTING 7974'-7 3/8" SITE PROPOSED (MOST RESTRICTIVE) C XXXX'-X" ROOF HEIGHT XX'-X" XXXX'-X" SITE EXISTING XX'-X" XXXX'-X" SITE PROPOSED (MOST RESTRICTIVE) XX'-X"" DEFINITIONS (SECTION 26.104.100) HEIGHT, BUILDING THE HEIGHT OF A BUILDING SHALL BE THE MAXIMUM DISTANCE POSSIBLE MEASURED VERTICALLY FROM NATURAL GRADE AT ANY POINT WITHIN THE INTERIOR OF THE BUILDING; AND FROM NATURAL OR FINISHED GRADE (WHICHEVER IS LOWER) AT ANY POINT AROUND THE PERIMETER OF THE BUILDING TO THE HIGHEST POINT OR STRUCTURE WITHIN A VERICAL PLANE. (SEE SUPPLEMENARY REGULATIONS SECTION 26.575.020, MEASURMENT AND CALCULATIONS).25'-0"EXISTING GRADE PROPOSED GRADE25'-0"EXISTING GRADE PROPOSED GRADE 25'-0"EXISTING GRADE PROPOSED GRADE25'-0"EXISTING GRADE PROPOSED GRADE SCALE: 1/4" = 1'-0"1Office - North Elevation 0 2'4'8'SCALE: 1/4" = 1'-0"2Office - East Elevation 0 2'4'8' SCALE: 1/4" = 1'-0"3Office - South Elevation 0 2'4'8'SCALE: 1/4" = 1'-0"4Office - West Elevation 0 2'4'8' THESE PLANS ARE CONCEPTUAL IN NATURE. INDIVIDUAL BUILDING PLANS MAY VARY BUT WILL BE EVALUATED FOR COMPLIANCE WITH DESIGN STANDARDS CONTAINED WITHIN SECTION 26.575.020 OF THE CITY OF ASPEN MUNICIPAL CODE AT THE TIME OF SUBMITTING A BUILDING PERMIT APPLICATION. Page 33 of 110 67224 A0.02 PROPOSED SITE AND EXTERIOR LIGHTING PLAN NOT FOR CONSTRUCTION 1/30/2023COUNCIL + ANDERSSON / WISE 807 Brazos St #800 Austin TX 78701 RED 1001 Grand Ave #103 Glenwood Springs CO 81601 © These documents have been specifically prepared for 108 Midland Avenue. They are not suitable for use on other projects or in other locations without the approval and participation of the architect. Reproduction prohibited without approval of the architect. 2023 Haynes Residence 108 Midland Avenue Aspen, CO 81611 SITE NOTES ① GREY BACKGROUND DENOTES EXISTING SURVEY FLOOR ELEVATIONS SECOND FLOOR - T.O. PLY. = 111'-0" (SITE = 7985'-11 1/4") FIRST FLOOR - T.O. PLY. = 100'-0" (SITE = 7974'-11 1/4") FIRST FLOOR OFFICE - T.O. CONC. = 99'-0" (SITE = 7973'-11 1/4") GARAGE - T.O. CONC. = 98'-0" (SITE = 7972'-11 1/4") MECH CRAWL - T.O. CONC. = 93'-3 3/4" (SITE = 7967'-10 1/2") BASEMENT - T.O. PLY. = 89'-11 1/4" (SITE = 7966'-0") BASEMENT - T.O. PLY. = 88'-11 1/4" (SITE = 7965'-0") BASEMENT - T.O. PLY. = 87'-11 1/4" (SITE = 7964'-0") SET REBAR & CAP LS No. 38342 FOUND MONUMENT AS DESCRIBED SITE LEGEND EASEMENT FENCE PROPOERTY LINE EXISTING GRADE PROPOSED GRADE SETBACK LINE TREE TO BE RETAINED AS REQ'D TREE TO BE REMOVED TREE LEGEND EXISTING HOUSE CONCEPTUAL LOCATION AND FOOTPRINT OF PROPOSED HOUSE LIGHTING LEGEND 26.02 IN-GRADE LIGHT FIXTURE 26.03 RECESSED WALL LIGHT N TREE TABLE TRUNK DIAMETER IN INCHES, DRIPLINE IN FEET D = DECIDUOUS, C = CONIFER TREE #TREE TYPE DIAMETER DRIPLINE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 C D C C C C C C C C C C C C C C C C C C C C C C C C C C D D D D D D D D D D D D D D D D D D D D D D D 21 12 7 10 11 12 11 11 9 11 21 10 9 6 14 13 13 10 12 10 8 9 10 13 8 7 14 12 14 17 14 18 12 10 10 11 13 15 14 12 14 12 10 9 10 7 12 10 9 13 9 20 12 12 9 10 14 9 6 6 15 10 14 10 13 8 8 7 10 10 6 8 4 7 4 5 5 9 5 7 4 5 4 6 4 4 4 4 9 9 8 10 7 8 8 8 6 9 8 11 11 10 52 53 54 55 56 57 58 59 60 61 62 63 64 65 C C C C C C C C D D D D D D 10 13 12 9 9 12 11 14 8 14 9 11 9 14 9 14 9 11 10 11 10 14 11 9 8 7 11 810'10'25 '25'39'-5.5"1 2 3 4 5 6 7 8 1 0 1 1 2 3 2 2 2 4 2 5 2 6 2 7 2 8 2 9 3 0 3 3 3 2 3 1 9 1 2 1 3 1 4 2 0 1 8 1 9 1 5 1 7 1 6 2 1 3 7 5 0 4 9 4 8 4 7 4 6 4 5 4 4 4 3 4 2 4 1 4 0 3 9 3 8 3 6 3 5 3 4 5 2 5 4 5 6 5 5 6 5 6 3 6 4 5 1 5 3 5 8 6 0 5 9 6 2 5 7 83'-4.5" PARKING SPACE (TYP.) FIRE TRUCK TURNAROUND HOSE BIB HOSE BIB HOSE BIB HOSE BIB 2.01 26.02 26.02 26.02 26.03 26.03 26.03 26.03 26.03 32.04 32.04 32.04 32.04 26.02 26.02 26.02 26.02 26.02 26.02 26.02 26.03 26.03 32.02 32.02 32.02 32.02 32.05 35.02 32.02 32.02 32.02 AUTOCOURT OPEN NO FENCE ACCESS PROPERTY LINESIDE SETBACKREAR SETBACK FRONT SETBACK SIDE SETBACKPROPERTY L INE MIDLAND AVE CONCRETE SID E W A L K MECH ENCLOSURETRASH 7980798579807 98 0 7975797579707970 797 5 79 6 5 796 0 7 9 6 5 796 0 79 6 5 797 0 796 0 797 0 797 5 79857980 104 MIDLAND AVE 10'15'46 '-9 .5 "20'-10.5" 12'-6 1/2"NSCALE: 1" = 10'1Proposed Site Plan 0 5'10'20' THESE PLANS ARE CONCEPTUAL IN NATURE. INDIVIDUAL BUILDING PLANS MAY VARY BUT WILL BE EVALUATED FOR COMPLIANCE WITH DESIGN STANDARDS CONTAINED WITHIN SECTION 26.575.020 OF THE CITY OF ASPEN MUNICIPAL CODE AT THE TIME OF SUBMITTING A BUILDING PERMIT APPLICATION. Page 34 of 110 68225 A0.02 PROPOSED SITE PLAN TREE REMOVALS NOT FOR CONSTRUCTION 5/22/2023PERMIT + ANDERSSON / WISE 807 Brazos St #800 Austin TX 78701 RED 1001 Grand Ave #103 Glenwood Springs CO 81601 © These documents have been specifically prepared for 108 Midland Avenue. They are not suitable for use on other projects or in other locations without the approval and participation of the architect. Reproduction prohibited without approval of the architect. 2023 Haynes Residence 108 Midland Avenue Aspen, CO 81611 SET REBAR & CAP LS No. 38342 FOUND MONUMENT AS DESCRIBED SITE LEGEND EASEMENT FENCE PROPOERTY LINE EXISTING GRADE PROPOSED GRADE SETBACK LINE TREE TO BE RETAINED AS REQ'D TREE TO BE REMOVED TREE LEGEND EXISTING HOUSE CONCEPTUAL LOCATION AND FOOTPRINT OF PROPOSED HOUSE LIGHTING LEGEND 26.02 IN-GRADE LIGHT FIXTURE 26.03 RECESSED WALL LIGHT SITE NOTES ① FIRST FLOOR FINISH ELEVATION 100'-0" = 7975'-0" ② SEE SHEET G0.40 AND G0.41 FOR WALL AND PARITION TYPES ③ SEE SHEET A6.00 FOR WINDOW TYPES AND SCHEDULES ④ SEE SHEET A6.50 FOR DOOR TYPES AND SCHEDULES ⑤ SEE SHEET G0.50 FOR FINISH, EQUIPMENT, AND ACCESSORIES SCHEDULE ⑥ ALL DIMENSIONS ARE TO STRUCTURAL GRID, FACE OF CONCRETE, OR FACE OF FRAMING UNLESSS NOTED OTHERWISE ⑦ ALL WINDOW LOCATION DIMENSIONS ARE REFERENCED TO THE CENTERLINE OF WINDOW UNIT. SEE SHEET A6.00 FOR ROUGH OPENING DIMENSIONS ⑧ ALL ARCHITECTURAL STEEL OR STEEL W/ WELDS EXPOSED TO VIEW SHALL BE GROOVE OR PUDDLE WELDED AND GROUND SMOOTH FOR A SEAMLESS APPEARANCE, UNLESS OTHERWISE DETAILED OR APPROVED BY ARCHITECT ⑨ ALL EXTERIOR ELECTRICAL OUTLETS AND HOSE BIBS ARE LOCATED 1'-3" A.F.F. TO CENTERLINE SITE NOTES① FIRST FLOOR FINISH ELEVATION 100'-0" = 7975'-0"② SEE SHEET G0.40 AND G0.41 FOR WALL AND PARITION TYPES③ SEE SHEET A6.00 FOR WINDOW TYPES AND SCHEDULES④ SEE SHEET A6.50 FOR DOOR TYPES AND SCHEDULES⑤ SEE SHEET G0.50 FOR FINISH, EQUIPMENT, AND ACCESSORIES SCHEDULE ⑥ ALL DIMENSIONS ARE TO STRUCTURAL GRID, FACE OF CONCRETE, OR FACE OF FRAMING UNLESSS NOTED OTHERWISE ⑦ ALL WINDOW LOCATION DIMENSIONS ARE REFERENCED TO THE CENTERLINE OF WINDOW UNIT. SEE SHEET A6.00 FOR ROUGH OPENING DIMENSIONS ⑧ ALL ARCHITECTURAL STEEL OR STEEL W/ WELDS EXPOSED TO VIEW SHALL BE GROOVE OR PUDDLE WELDED AND GROUND SMOOTH FOR A SEAMLESS APPEARANCE, UNLESS OTHERWISE DETAILED OR APPROVED BY ARCHITECT ⑨ ALL EXTERIOR ELECTRICAL OUTLETS AND HOSE BIBS ARE LOCATED 1'-3" A.F.F. TO CENTERLINE N10'10'25 '25'39'-5.5"1 2 3 4 5 6 7 8 1 0 1 1 2 3 2 2 2 4 2 5 2 6 2 7 2 8 2 9 3 0 3 4 3 3 3 1 9 1 2 1 3 1 4 2 0 1 8 1 9 1 5 1 7 1 6 2 1 3 7 5 0 4 9 4 8 4 7 4 6 4 5 4 4 4 3 4 2 4 1 4 0 3 9 3 8 3 6 3 5 5 2 5 4 5 6 5 5 6 5 6 3 6 4 5 1 5 3 5 8 6 0 5 9 6 2 5 7 83'-4.5" 3 2 PARKING SPACE (TYP.) FIRE TRUCK TURNAROUND HOSE BIB HOSE BIB HOSE BIB HOSE BIB AUTOCOURT OPEN NO FENCE ACCESS PROPERTY LINESIDE SETBACKREAR SETBACK FRONT SETBACK SIDE SETBACKPROPERTY LINE MIDLAND AVE CONCRETE SIDEWALK MECH ENCLOSURETRASH 798079857980798 0 7975797579707970 797 5 79 6 5 796 0 7 9 6 5 796 0 79 6 5 797 0 796 0 797 0 797 5 79857980 104 MIDLAND AVE 10'15'46 '-9 .5 "20'-10.5" 12'-6 1/2" KEYNOTES 2.01 EXISTING TREE: REF: SURVEY 26.02 IN GRADE LIGHT FIXTUREl REFER TO SITE PLAN & RCPs; REF: LIGHT FIXTURE SCHEDULE 26.03 RECESSED WALL LIGHT; REFER TO SITE PLAN & RCPS; REF: LIGHT FIXTURE SCHEDULE 32.02 STONE RETAINING WALL; REF: CIVIL 32.04 STONE FENCE 32.05 FIRE TRUCK TURNAROUND; REF: CIVIL SCALE: 1" = 10'1Proposed Site Plan 0 5'10'20' 69226 A0.03 MH- BASEMENT PLAN NOT FOR CONSTRUCTION 1/30/2023COUNCIL + ANDERSSON / WISE 807 Brazos St #800 Austin TX 78701 RED 1001 Grand Ave #103 Glenwood Springs CO 81601 © These documents have been specifically prepared for 108 Midland Avenue. They are not suitable for use on other projects or in other locations without the approval and participation of the architect. Reproduction prohibited without approval of the architect. 2023 Haynes Residence 108 Midland Avenue Aspen, CO 81611 SITE NOTES ① GREY BACKGROUND DENOTES EXISTING SURVEY FLOOR ELEVATIONS SECOND FLOOR - T.O. PLY. = 111'-0" (SITE = 7985'-11 1/4") FIRST FLOOR - T.O. PLY. = 100'-0" (SITE = 7974'-11 1/4") FIRST FLOOR OFFICE - T.O. CONC. = 99'-0" (SITE = 7973'-11 1/4") GARAGE - T.O. CONC. = 98'-0" (SITE = 7972'-11 1/4") MECH CRAWL - T.O. CONC. = 93'-3 3/4" (SITE = 7967'-10 1/2") BASEMENT - T.O. PLY. = 89'-11 1/4" (SITE = 7966'-0") BASEMENT - T.O. PLY. = 88'-11 1/4" (SITE = 7965'-0") BASEMENT - T.O. PLY. = 87'-11 1/4" (SITE = 7964'-0")NTHESE PLANS ARE CONCEPTUAL IN NATURE. INDIVIDUAL BUILDING PLANS MAY VARY BUT WILL BE EVALUATED FOR COMPLIANCE WITH DESIGN STANDARDS CONTAINED WITHIN SECTION 26.575.020 OF THE CITY OF ASPEN MUNICIPAL CODE AT THE TIME OF SUBMITTING A BUILDING PERMIT APPLICATION.UPUPUPUPW/DW/D1 1 3 3 4 4 5 5 7 7 8 8 9 9 F F E E D D C C B B 1112 10 A A 2 2 6 6 T.O.F.F. BASEMENT 7967'-10 1/2" 7965'-0" T.O.F.F. BASEMENT 7965'-0" 7966'-0" 7966'-0" T.O.F.F. BASEMENT 7964'-0" 7964'-0" MECHANICAL CRAWL SPACE 013 A: 237 sq ft LAUNDRY 002 A: 70 sq ft ELEVATOR 000 A: 18 sq ft HALLWAY 001 A: 68 sq ft MASSAGE 007 A: 108 sq ft POWDER 3 003 A: 83 sq ft WINE STORAGE 005 A: 97 sq ft BASEMENT LIVING ROOM 004 A: 446 sq ft GYM 008 A: 110 sq ft GUEST BATH 1 012 A: 54 sq ft GUEST BEDROOM 1 011 A: 238 sq ft GUEST BEDROOM 2 010 A: 242 sq ft GUEST BATH 2 009 A: 55 sq ft MAIN STAIR 006 A: 35 sq ft 1 A2.04 1 A2.03 1 A2.02 1 A2.01 10' 25 'REAR SETBACKFRONT SETBACKPROPERTY LINEPROPERTY LINEFRONT SETBACKSCALE: 1/4" = 1'-0"1MH - Basement Plan 0 2'4'8' Page 35 of 110 70227 A0.04 MH - FIRST FLOOR PLAN NOT FOR CONSTRUCTION 1/30/2023COUNCIL + ANDERSSON / WISE 807 Brazos St #800 Austin TX 78701 RED 1001 Grand Ave #103 Glenwood Springs CO 81601 © These documents have been specifically prepared for 108 Midland Avenue. They are not suitable for use on other projects or in other locations without the approval and participation of the architect. Reproduction prohibited without approval of the architect. 2023 Haynes Residence 108 Midland Avenue Aspen, CO 81611 SITE NOTES ① GREY BACKGROUND DENOTES EXISTING SURVEY FLOOR ELEVATIONS SECOND FLOOR - T.O. PLY. = 111'-0" (SITE = 7985'-11 1/4") FIRST FLOOR - T.O. PLY. = 100'-0" (SITE = 7974'-11 1/4") FIRST FLOOR OFFICE - T.O. CONC. = 99'-0" (SITE = 7973'-11 1/4") GARAGE - T.O. CONC. = 98'-0" (SITE = 7972'-11 1/4") MECH CRAWL - T.O. CONC. = 93'-3 3/4" (SITE = 7967'-10 1/2") BASEMENT - T.O. PLY. = 89'-11 1/4" (SITE = 7966'-0") BASEMENT - T.O. PLY. = 88'-11 1/4" (SITE = 7965'-0") BASEMENT - T.O. PLY. = 87'-11 1/4" (SITE = 7964'-0")NTHESE PLANS ARE CONCEPTUAL IN NATURE. INDIVIDUAL BUILDING PLANS MAY VARY BUT WILL BE EVALUATED FOR COMPLIANCE WITH DESIGN STANDARDS CONTAINED WITHIN SECTION 26.575.020 OF THE CITY OF ASPEN MUNICIPAL CODE AT THE TIME OF SUBMITTING A BUILDING PERMIT APPLICATION. DOWNDOWNUP 1 1 3 3 4 4 5 5 7 7 8 8 9 9 F F E E D D C C B B 1112 10 A A 2 2 6 6W/DENTRY 1 A2.04 1 A2.03 1 A2.02 1 A2.01 ENTRY 101 A: 435 sq ft GARAGE 113 A: 672 sq ft POWDER 1 112 A: 30 sq ft ELEVATOR 111 A: 18 sq ft HER MASTER BEDROOM 106 A: 252 sq ft HER MASTER BATH 108 A: 99 sq ft HER MASTER CLOSET 107 A: 148 sq ft HIS MASTER BEDROOM 103 A: 255 sq ft HIS MASTER CLOSET 104 A: 109 sq ft HIS MASTER BATH 105 A: 151 sq ft 10' 25 'REAR SETBACKFRONT SETBACKPROPERTY LINEPROPERTY LINEFRONT SETBACKMUD ROOM 110 A: 197 sq ft SCALE: 1/4" = 1'-0"1MH - First Floor Plan 0 2'4'8' Page 36 of 110 71228 A0.05 MH - SECOND FLOOR PLAN NOT FOR CONSTRUCTION 1/30/2023COUNCIL + ANDERSSON / WISE 807 Brazos St #800 Austin TX 78701 RED 1001 Grand Ave #103 Glenwood Springs CO 81601 © These documents have been specifically prepared for 108 Midland Avenue. They are not suitable for use on other projects or in other locations without the approval and participation of the architect. Reproduction prohibited without approval of the architect. 2023 Haynes Residence 108 Midland Avenue Aspen, CO 81611 SITE NOTES ① GREY BACKGROUND DENOTES EXISTING SURVEY FLOOR ELEVATIONS SECOND FLOOR - T.O. PLY. = 111'-0" (SITE = 7985'-11 1/4") FIRST FLOOR - T.O. PLY. = 100'-0" (SITE = 7974'-11 1/4") FIRST FLOOR OFFICE - T.O. CONC. = 99'-0" (SITE = 7973'-11 1/4") GARAGE - T.O. CONC. = 98'-0" (SITE = 7972'-11 1/4") MECH CRAWL - T.O. CONC. = 93'-3 3/4" (SITE = 7967'-10 1/2") BASEMENT - T.O. PLY. = 89'-11 1/4" (SITE = 7966'-0") BASEMENT - T.O. PLY. = 88'-11 1/4" (SITE = 7965'-0") BASEMENT - T.O. PLY. = 87'-11 1/4" (SITE = 7964'-0")NTHESE PLANS ARE CONCEPTUAL IN NATURE. INDIVIDUAL BUILDING PLANS MAY VARY BUT WILL BE EVALUATED FOR COMPLIANCE WITH DESIGN STANDARDS CONTAINED WITHIN SECTION 26.575.020 OF THE CITY OF ASPEN MUNICIPAL CODE AT THE TIME OF SUBMITTING A BUILDING PERMIT APPLICATION.DOWN1 1 3 3 4 4 5 5 7 7 8 8 9 9 F F E E D D C C B B 1112 10 A A 2 2 6 6 DWDW A10A111 A2.04 1 A2.03 1 A2.02 1 A2.01 BUTLER'S PANTRY 204 A: 89 sq ft POWDER 2 202 A: 30 sq ft HALLWAY 201 A: 78 sq ft BREAKFAST NOOK 205 A: 46 sq ft LIVING ROOM 206 A: 333 sq ft BAR AND MUSIC ROOM 208 A: 252 sq ft BAR TERRACE 251 A: 215 sq ft 10' 25 ' LINE OF OVERHANG ABOVE REAR SETBACKFRONT SETBACKPROPERTY LINEPROPERTY LINEFRONT SETBACKKITCHEN 203 A: 325 sq ft DINING ROOM 207 A: 202 sq ft DINING TERRACE 250 A: 325 sq ft SCALE: 1/4" = 1'-0"1MH - Second Floor Plan 0 2'4'8' Page 37 of 110 72229 A0.06 MH - ROOF PLAN NOT FOR CONSTRUCTION 1/30/2023COUNCIL + ANDERSSON / WISE 807 Brazos St #800 Austin TX 78701 RED 1001 Grand Ave #103 Glenwood Springs CO 81601 © These documents have been specifically prepared for 108 Midland Avenue. They are not suitable for use on other projects or in other locations without the approval and participation of the architect. Reproduction prohibited without approval of the architect. 2023 Haynes Residence 108 Midland Avenue Aspen, CO 81611 ROOF PLAN NOTES ① ALL NEW ROOFS TO DRAIN TO GREEN SPACE GUTTER DOWNSPOUT CORRUGATED METAL ROOF MATERIAL ASPHALT ROOF SHINGLE MEMBRANE STANDING SEAMMETAL ROOFING METAL CHIMNEY NLINE OF OVERHANG ABOVE 1 1 3 3 4 4 5 5 7 7 8 8 9 9 F F E E D D C C B B A A 2 2 6 6 SOLAR READY AREA 631 sq ft 1 A2.04 1 A2.03 1 A2.02 1 A2.01 REAR SETBACKPROPERTY LINE10' 25 ' CHIMNEY LINE OF WALL FRAMING BELOW 7:127:12REAR SETBACKPROPERTY LINEREAR SETBACKFRONT SETBACKPROPERTY LINEFRONT SETBACKSCALE: 1/4" = 1'-0"1MH - Roof Plan 0 2'4'8' THESE PLANS ARE CONCEPTUAL IN NATURE. INDIVIDUAL BUILDING PLANS MAY VARY BUT WILL BE EVALUATED FOR COMPLIANCE WITH DESIGN STANDARDS CONTAINED WITHIN SECTION 26.575.020 OF THE CITY OF ASPEN MUNICIPAL CODE AT THE TIME OF SUBMITTING A BUILDING PERMIT APPLICATION. Page 38 of 110 73230 A0.07 OFFICE - PLANS NOT FOR CONSTRUCTION 1/30/2023COUNCIL + ANDERSSON / WISE 807 Brazos St #800 Austin TX 78701 RED 1001 Grand Ave #103 Glenwood Springs CO 81601 © These documents have been specifically prepared for 108 Midland Avenue. They are not suitable for use on other projects or in other locations without the approval and participation of the architect. Reproduction prohibited without approval of the architect. 2023 Haynes Residence 108 Midland Avenue Aspen, CO 81611 SITE NOTES ① GREY BACKGROUND DENOTES EXISTING SURVEY FLOOR ELEVATIONS SECOND FLOOR - T.O. PLY. = 111'-0" (SITE = 7985'-11 1/4") FIRST FLOOR - T.O. PLY. = 100'-0" (SITE = 7974'-11 1/4") FIRST FLOOR OFFICE - T.O. CONC. = 99'-0" (SITE = 7973'-11 1/4") GARAGE - T.O. CONC. = 98'-0" (SITE = 7972'-11 1/4") MECH CRAWL - T.O. CONC. = 93'-3 3/4" (SITE = 7967'-10 1/2") BASEMENT - T.O. PLY. = 89'-11 1/4" (SITE = 7966'-0") BASEMENT - T.O. PLY. = 88'-11 1/4" (SITE = 7965'-0") BASEMENT - T.O. PLY. = 87'-11 1/4" (SITE = 7964'-0")NTHESE PLANS ARE CONCEPTUAL IN NATURE. INDIVIDUAL BUILDING PLANS MAY VARY BUT WILL BE EVALUATED FOR COMPLIANCE WITH DESIGN STANDARDS CONTAINED WITHIN SECTION 26.575.020 OF THE CITY OF ASPEN MUNICIPAL CODE AT THE TIME OF SUBMITTING A BUILDING PERMIT APPLICATION. G G J J 1112 10 H H I I 1 3 A2.05 4 A2.05 1 A2.05 2 A2.05 UNCOVERED OUTDOOR MECH ENCLOSURE 6' TALL FENCE MECHANICAL EQUIPMENT TO NOT EXCEED 30" ABOVE OR BELOW GRADE PER COA CODE OFFICE 114 A: 154 sq ft WET BAR 116 A: 28 sq ft BATHROOM 115 A: 36 sq ft SIDE SETBACK PROPERTY LINE G J 1112 H I 3 A2.05 4 A2.05 1 A2.05 LINE OF WALL FRAMING BELOW 0.25:120.25:12 0.25:120.25:12SIDE SETBACK PROPERTY LINE SCALE: 1/4" = 1'-0"1Office - First Floor Plan 0 2'4'8'SCALE: 1/4" = 1'-0"2Office - Roof Plan 0 2'4'8' Page 39 of 110 74231 MECHANICAL ENCLOSURE SECTIONS NOT FOR CONSTRUCTION 5/22/2023PERMIT + ANDERSSON / WISE 807 Brazos St #800 Austin TX 78701 RED 1001 Grand Ave #103 Glenwood Springs CO 81601 © These documents have been specifically prepared for 108 Midland Avenue. They are not suitable for use on other projects or in other locations without the approval and participation of the architect. Reproduction prohibited without approval of the architect. 2023 Haynes Residence 108 Midland Avenue Aspen, CO 81611 STONE SIDING WOOD TIMBERS AND TRIM HORIZONTAL SIDING CORRUGATED METAL ROOFING ELEVATION MATERIAL METAL CHIMNEY METAL TBD ELEVATION NOTES ① FIRST FLOOR FINISH ELEVATION 100'-0" = 7975'-0" ② SEE SHEET G0.40 AND G0.41 FOR WALL AND PARTITION TYPES ③ SEE SHEET A6.00 FOR WINDOW TYPES AND SCHEDULES ④ SEE SHEET A6.50 FOR DOOR TYPES AND SCHEDULES ⑤ SEE SHEET G0.50 FOR FINISH, EQUIPMENT, AND ACCESSORIES SCHEDULE ⑥ ALL DIMENSIONS ARE TO STRUCTURAL GRID, FACE OF CONCRETE, OR FACE OF FRAMING UNLESS NOTED OTHERWISE ⑦ ALL WINDOW LOCATION DIMENSIONS ARE REFERENCED TO THE CENTERLINE OF WINDOW UNIT. SEE SHEET A6.00 FOR ROUGH OPENING DIMENSIONS ⑧ ALL ARCHITECTURAL STEEL OR STEEL W/ WELDS EXPOSED TO VIEW SHALL BE GROOVE OR PUDDLE WELDED AND GROUND SMOOTH FOR A SEAMLESS APPEARANCE, UNLESS OTHERWISE DETAILED OR APPROVED BY ARCHITECT ⑨ ALL EXTERIOR ELECTRICAL OUTLETS AND HOSE BIBS ARE LOCATED 1'-3" A.F.F. TO CENTERLINE ① FIRST FLOOR FINISH ELEVATION 100'-0" = 7975'-0"② SEE SHEET G0.40 AND G0.41 FOR WALL AND PARTITION TYPES③ SEE SHEET A6.00 FOR WINDOW TYPES AND SCHEDULES ④ SEE SHEET A6.50 FOR DOOR TYPES AND SCHEDULES ⑤ SEE SHEET G0.50 FOR FINISH, EQUIPMENT, AND ACCESSORIES SCHEDULE ⑥ ALL DIMENSIONS ARE TO STRUCTURAL GRID, FACE OF CONCRETE, OR FACE OF FRAMING UNLESS NOTED OTHERWISE ⑦ ALL WINDOW LOCATION DIMENSIONS ARE REFERENCED TO THE CENTERLINE OF WINDOW UNIT. SEE SHEET A6.00 FOR ROUGH OPENING DIMENSIONS ⑧ ALL ARCHITECTURAL STEEL OR STEEL W/ WELDS EXPOSED TO VIEW SHALL BE GROOVE OR PUDDLE WELDED AND GROUND SMOOTH FOR A SEAMLESS APPEARANCE, UNLESS OTHERWISE DETAILED OR APPROVED BY ARCHITECT ⑨ ALL EXTERIOR ELECTRICAL OUTLETS AND HOSE BIBS ARE LOCATED 1'-3" A.F.F. TO CENTERLINE 1'-6"12'-11"1'-6"6'-0"STONE FENCE STONE FENCE MECHANICAL ENCLOSUREBIKE STORAGE 1'-6"16'-10 1/2"6'-0"STONE FENCE MECHANICAL ENCLOSURE OFFICE SCALE: 1/2" = 1'-0"1Mech Enclosure N-S Section 0 1'2'4' SCALE: 1/2" = 1'-0"2Mech Enclosure E-W Section 0 1'2'4' 75232 A0.08 TRASH ENCLOSURE - PLANS NOT FOR CONSTRUCTION 1/30/2023COUNCIL + ANDERSSON / WISE 807 Brazos St #800 Austin TX 78701 RED 1001 Grand Ave #103 Glenwood Springs CO 81601 © These documents have been specifically prepared for 108 Midland Avenue. They are not suitable for use on other projects or in other locations without the approval and participation of the architect. Reproduction prohibited without approval of the architect. 2023 Haynes Residence 108 Midland Avenue Aspen, CO 81611 SITE NOTES ① GREY BACKGROUND DENOTES EXISTING SURVEY FLOOR ELEVATIONS SECOND FLOOR - T.O. PLY. = 111'-0" (SITE = 7985'-11 1/4") FIRST FLOOR - T.O. PLY. = 100'-0" (SITE = 7974'-11 1/4") FIRST FLOOR OFFICE - T.O. CONC. = 99'-0" (SITE = 7973'-11 1/4") GARAGE - T.O. CONC. = 98'-0" (SITE = 7972'-11 1/4") MECH CRAWL - T.O. CONC. = 93'-3 3/4" (SITE = 7967'-10 1/2") BASEMENT - T.O. PLY. = 89'-11 1/4" (SITE = 7966'-0") BASEMENT - T.O. PLY. = 88'-11 1/4" (SITE = 7965'-0") BASEMENT - T.O. PLY. = 87'-11 1/4" (SITE = 7964'-0")NTHESE PLANS ARE CONCEPTUAL IN NATURE. INDIVIDUAL BUILDING PLANS MAY VARY BUT WILL BE EVALUATED FOR COMPLIANCE WITH DESIGN STANDARDS CONTAINED WITHIN SECTION 26.575.020 OF THE CITY OF ASPEN MUNICIPAL CODE AT THE TIME OF SUBMITTING A BUILDING PERMIT APPLICATION. 1 A2.06 2 A2.06 TRASH A: 48 sq ft 1 A2.06 2 A2.06 SCALE: 1/4" = 1'-0"1Trash Enclosure - Floor Plan 0 2'4'8' SCALE: 1/4" = 1'-0"2Trash Enclosure - Roof Plan 0 2'4'8' Page 40 of 110 76233 A2.01 MH - EXTERIOR ELEVATIONS NOT FOR CONSTRUCTION 1/30/2023COUNCIL + ANDERSSON / WISE 807 Brazos St #800 Austin TX 78701 RED 1001 Grand Ave #103 Glenwood Springs CO 81601 © These documents have been specifically prepared for 108 Midland Avenue. They are not suitable for use on other projects or in other locations without the approval and participation of the architect. Reproduction prohibited without approval of the architect. 2023 Haynes Residence 108 Midland Avenue Aspen, CO 81611 STONE SIDING WOOD TIMBERS AND TRIM HORIZONTAL SIDING CORRUGATED METAL ROOFING ELEVATION MATERIAL METAL CHIMNEY METAL TBD 1 2 3 4 5 6 7 8 9 EXISTING GRADE PROPOSED GRADE SCALE: 1/4" = 1'-0"1MH - North Elevation 0 2'4'8' THESE PLANS ARE CONCEPTUAL IN NATURE. INDIVIDUAL BUILDING PLANS MAY VARY BUT WILL BE EVALUATED FOR COMPLIANCE WITH DESIGN STANDARDS CONTAINED WITHIN SECTION 26.575.020 OF THE CITY OF ASPEN MUNICIPAL CODE AT THE TIME OF SUBMITTING A BUILDING PERMIT APPLICATION. Page 41 of 110 77234 A2.02 MH - EXTERIOR ELEVATIONS NOT FOR CONSTRUCTION 1/30/2023COUNCIL + ANDERSSON / WISE 807 Brazos St #800 Austin TX 78701 RED 1001 Grand Ave #103 Glenwood Springs CO 81601 © These documents have been specifically prepared for 108 Midland Avenue. They are not suitable for use on other projects or in other locations without the approval and participation of the architect. Reproduction prohibited without approval of the architect. 2023 Haynes Residence 108 Midland Avenue Aspen, CO 81611 STONE SIDING WOOD TIMBERS AND TRIM HORIZONTAL SIDING CORRUGATED METAL ROOFING ELEVATION MATERIAL METAL CHIMNEY METAL TBD A B C D E F 30"EXISTING GRADE PROPOSED GRADE SCALE: 1/4" = 1'-0"1MH - East Elevation 0 2'4'8' THESE PLANS ARE CONCEPTUAL IN NATURE. INDIVIDUAL BUILDING PLANS MAY VARY BUT WILL BE EVALUATED FOR COMPLIANCE WITH DESIGN STANDARDS CONTAINED WITHIN SECTION 26.575.020 OF THE CITY OF ASPEN MUNICIPAL CODE AT THE TIME OF SUBMITTING A BUILDING PERMIT APPLICATION. Page 42 of 110 78235 A2.03 MH - EXTERIOR ELEVATIONS NOT FOR CONSTRUCTION 1/30/2023COUNCIL + ANDERSSON / WISE 807 Brazos St #800 Austin TX 78701 RED 1001 Grand Ave #103 Glenwood Springs CO 81601 © These documents have been specifically prepared for 108 Midland Avenue. They are not suitable for use on other projects or in other locations without the approval and participation of the architect. Reproduction prohibited without approval of the architect. 2023 Haynes Residence 108 Midland Avenue Aspen, CO 81611 STONE SIDING WOOD TIMBERS AND TRIM HORIZONTAL SIDING CORRUGATED METAL ROOFING ELEVATION MATERIAL METAL CHIMNEY METAL TBD 9 8 7 6 5 4 3 2 1 9'-0"1'-0"9'-0" 19'-0" SCALE: 1/4" = 1'-0"1MH - South Elevation 0 2'4'8' THESE PLANS ARE CONCEPTUAL IN NATURE. INDIVIDUAL BUILDING PLANS MAY VARY BUT WILL BE EVALUATED FOR COMPLIANCE WITH DESIGN STANDARDS CONTAINED WITHIN SECTION 26.575.020 OF THE CITY OF ASPEN MUNICIPAL CODE AT THE TIME OF SUBMITTING A BUILDING PERMIT APPLICATION. Page 43 of 110 79236 A2.04 MH - EXTERIOR ELEVATIONS NOT FOR CONSTRUCTION 1/30/2023COUNCIL + ANDERSSON / WISE 807 Brazos St #800 Austin TX 78701 RED 1001 Grand Ave #103 Glenwood Springs CO 81601 © These documents have been specifically prepared for 108 Midland Avenue. They are not suitable for use on other projects or in other locations without the approval and participation of the architect. Reproduction prohibited without approval of the architect. 2023 Haynes Residence 108 Midland Avenue Aspen, CO 81611 STONE SIDING WOOD TIMBERS AND TRIM HORIZONTAL SIDING CORRUGATED METAL ROOFING ELEVATION MATERIAL METAL CHIMNEY METAL TBD F E D C B A EXISTING GRADE PROPOSED GRADE SCALE: 1/4" = 1'-0"1MH - West Elevation 0 2'4'8' THESE PLANS ARE CONCEPTUAL IN NATURE. INDIVIDUAL BUILDING PLANS MAY VARY BUT WILL BE EVALUATED FOR COMPLIANCE WITH DESIGN STANDARDS CONTAINED WITHIN SECTION 26.575.020 OF THE CITY OF ASPEN MUNICIPAL CODE AT THE TIME OF SUBMITTING A BUILDING PERMIT APPLICATION. Page 44 of 110 80237 A2.05 OFFICE - EXTERIOR ELEVATIONS NOT FOR CONSTRUCTION 1/30/2023COUNCIL + ANDERSSON / WISE 807 Brazos St #800 Austin TX 78701 RED 1001 Grand Ave #103 Glenwood Springs CO 81601 © These documents have been specifically prepared for 108 Midland Avenue. They are not suitable for use on other projects or in other locations without the approval and participation of the architect. Reproduction prohibited without approval of the architect. 2023 Haynes Residence 108 Midland Avenue Aspen, CO 81611 STONE SIDING WOOD TIMBERS AND TRIM HORIZONTAL SIDING CORRUGATED METAL ROOFING ELEVATION MATERIAL METAL CHIMNEY METAL TBDEXISTING GRADE PROPOSED GRADE EXISTING GRADE PROPOSED GRADE EXISTING GRADE PROPOSED GRADE EXISTING GRADE PROPOSED GRADE SCALE: 1/4" = 1'-0"3Office - South Elevation 0 2'4'8'SCALE: 1/4" = 1'-0"4Office - West Elevation 0 2'4'8' SCALE: 1/4" = 1'-0"1Office - North Elevation 0 2'4'8'SCALE: 1/4" = 1'-0"2Office - East Elevation 0 2'4'8' THESE PLANS ARE CONCEPTUAL IN NATURE. INDIVIDUAL BUILDING PLANS MAY VARY BUT WILL BE EVALUATED FOR COMPLIANCE WITH DESIGN STANDARDS CONTAINED WITHIN SECTION 26.575.020 OF THE CITY OF ASPEN MUNICIPAL CODE AT THE TIME OF SUBMITTING A BUILDING PERMIT APPLICATION. Page 45 of 110 81238 A2.06 TRASH ENCLOSURE - EXTERIOR ELEVATIONS NOT FOR CONSTRUCTION 1/30/2023COUNCIL + ANDERSSON / WISE 807 Brazos St #800 Austin TX 78701 RED 1001 Grand Ave #103 Glenwood Springs CO 81601 © These documents have been specifically prepared for 108 Midland Avenue. They are not suitable for use on other projects or in other locations without the approval and participation of the architect. Reproduction prohibited without approval of the architect. 2023 Haynes Residence 108 Midland Avenue Aspen, CO 81611 STONE SIDING WOOD TIMBERS AND TRIM HORIZONTAL SIDING CORRUGATED METAL ROOFING ELEVATION MATERIAL METAL CHIMNEY METAL TBD 8'-0 5/16"SCALE: 1/4" = 1'-0"1Trash Enclosure - North Elevation 0 2'4'8'SCALE: 1/4" = 1'-0"2Trash Enclosure - West Elevation 0 2'4'8' Page 46 of 110 82239 FASCIA WINDOW FRAMES WOOD SIDING METAL ROOF Page 47 of 110 83240 Residential Design Standards Administrative Compliance Review Applicant Checklist - Single Family and Duplex Standard Complies Alternative Compliance N/A Sheet #(s)/Notes B.1.Articulation of Building Mass (Non-flexible) B.2.Building Orientation (Flexible) B.3.Build-to Requirement (Flexible) B.4.One Story Element (Flexible) C.1.Garage Access (Non-flexible) C.2.Garage Placement (Non-flexible) C.3.Garage Dimensions (Flexible) Instructions: Please fill out the checklist below, marking whether the proposed design complies with the applicable standard as written or is requesting Alternative Compliance (only permitted for Flexible standards). Also include the sheet #(s) demonstrating the applicable standard. If a standard does not apply, please mark N/A and include in the Notes section why it does not apply. If Alternative Compliance is requested for a Flexible standard, include in the Notes section how the proposed design meets the intent of the standard(s). Additional sheets/graphics may be attached. Disclaimer: This application is only valid for the attached design. If any element of the design subject to Residential Design Standards changes prior to or during building permit review, the applicant shall be required to apply for a new Administrative Compliance Review. Address: Parcel ID: Zone District/PD: Representative: Email: Phone: Page 1 of 2Page 48 of 110 84241 Standard Complies Alternative Compliance N/A Sheet #(s)/Notes C.4.Garage Door Design (Flexible) D.1.Entry Connection (Non-flexible) D.2.Door Height (Flexible) D.3.Entry Porch (Flexible) E.1.Principle Window (Flexible) E.2.Window Placement (Flexible) E.3.Nonorthogonal Window Limit (Flexible) E.4.Lightwell/Stairwell Location (Flexible) E.5.Materials (Flexible) Disclaimer: This application is only valid for the attached design. If any element of the design subject to Residential Design Standards changes prior to or during building permit review, the applicant shall be required to apply for a new Administrative Compliance Review. Page 2 of 2 Residential Design Standards Administrative Compliance Review Applicant Checklist - Single Family and Duplex Page 49 of 110 85242 86243 X T X T X T X T X TXTXT XT XT XT X T X TXTXTXTXT XTXTXTXTXTXTXTXTXTS GE SNYDER PARK FERGUSON EXEMPTION LOT A OF LOT 4 SPLIT E X U E X U E X U EXUEXUEXU E XU E XU E X U E X U E X U EXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUE XUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEGT C XWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWSXWSXWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWXWXWXWXW S XW S XC XC XC XC XCXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGX G X G X G X G X G X G X G XG XG XG XG XG XG XG XG XGXGXGXGXGXG XG XG XG XG XG XG X G XGXGXG XG XG XG XG XG XG XG XG XG XG XG XG XGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXSSXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXCXCXCXCXCXCXCXC XC XC XC XC XC XC XC XC XC XC XC XC T E WS WS WS WS WS WSWSWSWSWSWSWSWSWSWS WS WS WS WS WSWSWSWSWSWSWSWSWSWSWSWSWS WS WS GGGGGG G G GGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGWS WS WS WS WS WS WS C C C C C CGGGGGGGGGGGG SSSS SSSSSSSSSSSSSS SS SS SS SS SS SS SS SS SS SS TTT TTTTTTTT T T T T T T T T T UEUEU E UEUEUEUEUEUEUE UE UE UE UE UE UE UE UEUE XSSXSSXSSXSSXSSXSSXSSXSS XSS XSS XSS XSS XSS XSS XSS OC< 0 00 0 98PC: 0+02.69PT: 0+05.80PC: 0+13.84PT: 0+28.00PC: 0+37.74PT: 0+68. 2 2 PC: 0+77. 3 6 PT: 0+90.51Start WalkwaySTA:0+00.00N:5221.70E:4722.94End WalkwaySTA:0+98.22N:5168.77E:4797.151002002 08 PT : 0 + 5 0 . 6 1 P C : 0 + 7 0 . 1 6 P T : 1 + 0 0 . 9 1 P C : 1 + 2 4 . 6 1 PT: 1 + 3 9 . 0 7 End 1 0 8 M i d l a n d D r i v e w a y A l i g n m e n t STA : 2 + 0 7 . 7 5 N:51 5 1 . 1 4 E:47 4 2 . 4 7 100200PC: 0 + 4 5 . 5 4 PT: 1 + 9 6 . 2 6 PC: 2 + 1 7 . 0 2 PT: 2+ 8 0 . 0 2 2010020200202 97 PC: 2 0 0 + 6 4 . 1 3 PT: 2 0 2 + 1 6 . 4 1 PC: 2 0 2 + 3 7 . 1 7 End Fl o w L i n e A l i g n m e n t STA:2 0 2 + 9 7 . 3 0 N:522 9 . 3 7 E:472 2 . 7 8 12.0% 12.7% 0 . 7% 00 10100101 25 P T : 1 0 1 + 0 7 . 7 7 Start 104 Midland Driveway AlignmentSTA:100+00.00E:4607.42E n d 1 0 4 M i d l a n d D r i v e w a y A l i g n m e n t S T A : 1 0 1 + 2 5 . 0 0 N: 5 0 3 5 . 3 3 E: 4 7 2 0 . 8 1 Structure - (3) Structure - (4)Pipe - (2 ) Structure - (5)Pipe - (3)Structure - (6) Pipe - (4) Structure - (7)Pipe - (5)Structure - (8) Structure - (9) Pipe - ( 6 ) Structure - (10) Structure - (11)Pipe - (7) Structure - (12) Pip e - ( 8 )Pipe - (9 ) Structure - (14)Pipe - (10)Structure - (15) Structure - (16)Pipe - (11)Pipe - (12) Structure - (17) Structure - (18) Zone 2/2a 7960'-0" 7965'-0" 7970'-0" 7975'-0" 7 9 6 5 ' - 0 " 7 9 7 0 ' - 0 " 7980'-0" 7985'-0" 7975'-0" 7980'-0" 7960'-0" 7965'-0" 7970'-0"RE A R Y A R D S E T B A C K 10' - 0 "SIDE YARD SETBACK10'-0"FRO N T Y A R D S E T B A C K 25'-0 "SIDE YARD SETBACK10'-0"TRA S H EN C L O S U R E MECHANICAL ENCLOSURE 7975'-0" 7973'-0" 7975'-0"PROPERTY LINEPROPERTY LINEPR O P E R T Y L I N E PROP E R T Y L I N E BIKESTORAGEMIDLAND AVE75+ +77 75++74.95 +73.95 795 7 ( 5 7 ) +79 +81.5 +84 +81.5 +80.5 +83.5+86+80+82.52 X FRONT YARD SETBACK71 Top 72? Bottom 70.75? +74.85 +71.35 +70 +67 +66.7+64.2+63.9+61.9Zone 1 Zone 4 Zone 4 Zone 4 Zone 4 Zone 8 Key Existing Evergreen to Remain Existing Deciduous to Remain Proposed 10-16' Evergreen (Zone 7) Proposed 2.5-4" Deciduous (Zone 6) Proposed #2 or #5 Deciduous (Zone 3) Proposed 4-6' Deciduous (Zone 3) Proposed Accent Specialty Evergreen (Zone 3) Perennials and Ground Covers (Garden Zone 2 and 2a) 10 0 10 20 30 Scale 1" = 10'Page 51 of 110 87244 Key Existing Evergreen to Remain Existing Deciduous to Remain Proposed 10-16' Evergreen (Zone 7) Proposed 2.5-4" Deciduous (Zone 6) Proposed #2 or #5 Deciduous (Zone 3) Proposed 4-6' Deciduous (Zone 3) Proposed Accent Specialty Evergreen (Zone 3) Perennials and Ground Covers (Garden Zone 2 and 2a) X T X T X T X T X TXTXT XT XT XT X T X TXTXTXTXT XTXTXTXTXTXTXTXTXTS GE SNYDER PARK FERGUSON EXEMPTION LOT A OF LOT 4 SPLIT E X U E X U E X U EXUEXUEXU E XU E XU E X U E X U E X U EXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUE XUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEGT C XWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWSXWSXWSXWSXWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWXWXWXW S XW S X W S X W S XWS XWS XWS XWS XC XC XC XC XC XC XC XC XC XC XC XC XCXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGX G X G X G X G X G X G X G XG XG XG XG XG XG XG XG XGXGXGXGXGXG XG XG XG XG XG XG X G XGXGXG XG XG XG XG XG XG XG XG XG XG XG XG XGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXSSXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXCXCXCXCXCXCXCXC XC XC XC XC XC XC XC XC XC XC XC XC T E WS WS WS WS WS WSWSWSWSWSWSWSWSWSWSWS WS WS WS WSWSWSWSWSWSWSWSWSWSWSWSWS WS WS GGGGGG G G GGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGWS WS WS WS WS WS WS WS WS WS WS WS WS C C C C C C C C C C C C C C CGGGGGGG G G G G G G G G G G G G G G G GGGSSSS SSSSSSSSSSSSSS SS SS SS SS SS SS SS SS SS SS TTT TTTTTTTT T T T T T T T T T UEUEU E UEUEUEUEUEUEUE UE UE UE UE UE UE UE UEUE XSSXSSXSSXSSXSSXSSXSSXSS XSS XSS XSS XSS XSS XSS XSS OC< 0 00 0 98PC: 0+02.69PT: 0+05.80PC: 0+13.84PT: 0+28.00PC: 0+37.74PT: 0+68. 2 2 PC: 0+77. 3 6 PT: 0+90.51Start WalkwaySTA:0+00.00N:5221.70E:4722.94End WalkwaySTA:0+98.22N:5168.77E:4797.151002002 08 PC: 0+15.69PT : 0 + 5 0 . 6 1 P C : 0 + 7 0 . 1 6 P T : 1 + 0 0 . 9 1 P C : 1 + 2 4 . 6 1 PT: 1 + 3 9 . 0 7 End 1 0 8 M i d l a n d D r i v e w a y A l i g n m e n t STA : 2 + 0 7 . 7 5 N:51 5 1 . 1 4 E:47 4 2 . 4 7 100200PC: 0 + 4 5 . 5 4 PT: 1 + 9 6 . 2 6 PC: 2 + 1 7 . 0 2 PT: 2+80.0 2 2010020200202 97 PC: 2 0 0 + 6 4 . 1 3 PT: 2 0 2 + 1 6 . 4 1 PC: 2 0 2 + 3 7 . 1 7 End Fl o w L i n e A l i g n m e n t STA:2 0 2 + 9 7 . 3 0 N:522 9 . 3 7 E:472 2 . 7 8 1.9%12.0% 12.7%1.9%0 . 7%5.0%5.3%10100101 25 PC: 100+12.31P T : 1 0 1 + 0 7 . 7 7 Start 104 Midland Driveway AlignmentE n d 1 0 4 M i d l a n d D r i v e w a y A l i g n m e n t S T A : 1 0 1 + 2 5 . 0 0 N: 5 0 3 5 . 3 3 E: 4 7 2 0 . 8 1 Structure - (3) Structure - (4)Pipe - (2 ) Structure - (5)Pipe - (3)Structure - (6) Pipe - (4) Structure - (7)Pipe - (5)Structure - (8) Structure - (9) Pipe - ( 6 ) Structure - (10) Structure - (11)Pipe - (7) Structure - (12) Pip e - ( 8 )Pipe - (9 ) Structure - (14)Pipe - (10)Structure - (15) Structure - (16)Pipe - (11)Pipe - (12) Structure - (17) Structure - (18) Zone 2/2a 7960'-0" 7965'-0" 7970'-0" 7975'-0" 7 9 6 5 ' - 0 " 7 9 7 0 ' - 0 " 7980'-0" 7985'-0" 7975'-0" 7980'-0" 7960'-0" 7965'-0" 7970'-0"RE A R Y A R D S E T B A C K 10'- 0 "SIDE YARD SETBACK10'-0"FRO N T Y A R D S E T B A C K 25'-0"SIDE YARD SETBACK10'-0"TRA S H EN C L O S U R E MECHANICAL ENCLOSURE 7975'-0" 7973'-0" 7975'-0"PROPERTY LINEPROPERTY LINEPR O P E R T Y L I N E PROP E R T Y L I N E BIKESTORAGEMIDLAND AVE75+ +77 75++74.95 +73.95 795 7 ( 5 7 ) +79 +81.5 +84 +81.5 +80.5 +83.5+86+80+82.52 X FRONT YARD SETBACK71 Top 72? Bottom 70.75? +74.85 +71.35 +70 +67 +66.7+64.2+63.9+61.9Zone 1 Zone 4 Zone 4 Zone 4 Zone 4 Zone 8 Ex:83.36 Ex:85.21 Ex:82.52 Ex:82.59 Ex:78.53 Ex:79.22 72.85 Ex:76.80 Ex:79.13 Ex:78.23 Ex:83.71 72.85 71.46 75.15 72.65 72.15 76.71 77.5477.54 73.72 76.31 76.31 76.81 76.81 80.31 80.31 68.96 71.46 68.96 65.55 66.19 68.69 68.44 65.94 65.51 65.71 72.97 73.00 73.00 65.71 Ex:66.83 Ex:69.42 73.00 72.97 72.35 TD:72.36 BOW:72.97 73.00 BOW:72.36 71.76 76.31 76.31 76.81 76.81 74.21 73.72 79.31 79.31 79.3179.00 76.71 77.54 77.54 78.53 80.31 Ex:82.59 80.31 Ex:82.52 TOW:85.21 TOW:83.68 TOW:83.36 BOW:63.01 TOW:65.51 BOW:64.52TOW:67.02 BOW:67.59TOW:70.09 BOW:68.96TOW:71.46 BOW:71.96TOW:72.85 BOW:69.65 TOW:72.15 BOW:72.65TOW:75.15 BOW:63.84TOW:65.71 BOW:65.87TOW:67.21 BOW:68.95TOW:??? TOW:65.56BOW:65.05 TOW:70.09 BOW:67.59 TOW:71.42 BOW:68.92 TOW:72.50 BOW:70.00 TD:72.16 TOW:78.24 BOW:71.09 TOW:79.21 BOW:72.83 72.87 59.23 69.03 71.89 73.07 73.62 74.79 EntryF.F.75.00 71.82 71.57 71.53 71.23 70.59 71.10 10 0 10 20 30 Scale 1" = 10' Note: All Disturbed Areas to be revegetated with an approved seed mix and Stabilized As Necessarry Areas Gardens 509 sf+136sf+89sf= 614 Lawn 665 sf Native 2,524+6838 sf=9,392 Page 52 of 110 88245 X T X T X T X T X TXTXT XT XT XT X T X TXTXTXTXT XTXTXTXTXTXTXTXTXTXTS GE SNYDER PARK FERGUSON EXEMPTION LOT A OF LOT 4 SPLIT E X U E X U E X U EXUEXUEXU E XU E XU E X U E X U E X U EXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUE XUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEGT C XWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWSXWSXWSXWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWXWXWXWXW S XW S X W S XWS XWSXCXCXCXCXCXCXCXCXC XCXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGX G X G X G X G X G X G X G XG XG XG XG XG XG XG XG XGXGXGXGXGXG XG XG XG XG XG XG X G XGXGXG XG XG XG XG XG XGXG XG XG XG XG XG XGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXSSXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXCXCXCXCXCXCXCXC XC XC XC XC XC XC XC XC XC XC XC XC T E WS WS WS WS WS WSWSWSWSWSWSWSWSWSWSWS WS WS WS WSWSWSWSWSWSWSWSWSWSWSWSWS WS WS GGGGGG G G GGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGWS WS WS WS WS WS WS WS WS WS C C C C C C C CGGGGGGG G G G G G GGGGSSSS SSSSSSSSSSSSSS SS SS SS SS SS SS SS SS SS SS TTT TTTTTTTT T T T T T T T T T UEUEU E UEUEUEUEUEUEUE UE UE UE UE UE UE UE UEUE XSSXSSXSSXSSXSSXSSXSSXSS XSS XSS XSS XSS XSS XSS XSS OC< 0 00 0 98PC: 0+02.69PT: 0+05.80PC: 0+13.84PT: 0+28.00PC: 0+37.74PT: 0+68. 2 2 PC: 0+77. 3 6 PT: 0+90.51Start WalkwaySTA:0+00.00N:5221.70E:4722.94End WalkwaySTA:0+98.22N:5168.77E:4797.151002002 08 PT : 0 + 5 0 . 6 1 P C : 0 + 7 0 . 1 6 P T : 1 + 0 0 . 9 1 P C : 1 + 2 4 . 6 1 PT: 1 + 3 9 . 0 7 STA:0+00.00End 1 0 8 M i d l a n d D r i v e w a y A l i g n m e n t STA : 2 + 0 7 . 7 5 N:51 5 1 . 1 4 E:47 4 2 . 4 7 100200PC: 0 + 4 5 . 5 4 PT: 1 + 9 6 . 2 6 PC: 2 + 1 7 . 0 2 PT: 2+ 8 0 . 0 2 2010020200202 97 PC: 2 0 0 + 6 4 . 1 3 PT: 2 0 2 + 1 6 . 4 1 PC: 2 0 2 + 3 7 . 1 7 End Fl o w L i n e A l i g n m e n t STA:2 0 2 + 9 7 . 3 0 N:522 9 . 3 7 E:472 2 . 7 8 1.9%12.0% 12.7%1.9%0. 7%5.0%5.3%00 10100101 25 PC: 100+12.31P T : 1 0 1 + 0 7 . 7 7 Start 104 Midland Driveway AlignmentSTA:100+00.00E:4607.42E n d 1 0 4 M i d l a n d D r i v e w a y A l i g n m e n t S T A : 1 0 1 + 2 5 . 0 0 N: 5 0 3 5 . 3 3 E: 4 7 2 0 . 8 1 Structure - (3) Structure - (4)Pipe - (2 ) Structure - (5)Pipe - (3)Structure - (6) Pipe - (4) Structure - (7)Pipe - (5)Structure - (8) Structure - (9) Pipe - ( 6 ) Structure - (10) Structure - (11)Pipe - (7) Structure - (12) Pip e - ( 8 )Pipe - (9 ) Structure - (14)Pipe - (10)Structure - (15) Structure - (16)Pipe - (11)Pipe - (12) Structure - (17) Structure - (18) Zone 2/2a 7960'-0" 7965'-0" 7970'-0" 7975'-0" 7 9 6 5 ' - 0 " 7 9 7 0 ' - 0 " 7980'-0" 7985'-0" 7975'-0" 7980'-0" 7960'-0" 7965'-0" 7970'-0"RE A R Y A R D S E T B A C K 10'- 0 "SIDE YARD SETBACK10'-0"FRO N T Y A R D S E T B A C K 25'-0"SIDE YARD SETBACK10'-0"TRA S H EN C L O S U R E MECHANICAL ENCLOSURE 7975'-0" 7973'-0" 7975'-0"PROPERTY LINEPROPERTY LINEPR O P E R T Y L I N E PROP E R T Y L I N E BIKESTORAGEMIDLAND AVE75+ +77 75++74.95 +73.95 795 7 ( 5 7 ) +79 +81.5 +84 +81.5 +80.5 +83.5+86+80+82.52 X FRONT YARD SETBACK71 Top 72? Bottom 70.75? +74.85 +71.35 +70 +67 +66.7+64.2+63.9+61.9Zone 1 Zone 4 Zone 4 Zone 4 Zone 4 Zone 8 Key Existing Evergreen to Remain Existing Deciduous to Remain Proposed 10-16' Evergreen (Zone 7) Proposed 2.5-4" Deciduous (Zone 6) Proposed #2 or #5 Deciduous (Zone 3) Proposed 4-6' Deciduous (Zone 3) Proposed Accent Specialty Evergreen (Zone 3) Perennials and Ground Covers (Garden Zone 2 and 2a) Path Light 10 0 10 20 30 Scale 1" = 10' Note: All Disturbed Areas to be revegetated with an approved seed mix and Stabilized As Necessarry Areas Gardens 509 sf+136sf+89sf= 614 Lawn 665 sf Native 2,524+6838 sf=9,392 Page 53 of 110 89246 A0.02 PROPOSED SITE AND EXTERIOR LIGHTING PLAN NOT FOR CONSTRUCTION 1/26/2023COUNCIL + ANDERSSON / WISE 807 Brazos St #800 Austin TX 78701 RED 1001 Grand Ave #103 Glenwood Springs CO 81601 © These documents have been specifically prepared for 108 Midland Avenue. They are not suitable for use on other projects or in other locations without the approval and participation of the architect. Reproduction prohibited without approval of the architect. 2023 Haynes Residence 108 Midland Avenue Aspen, CO 81611 SITE NOTES ① GREY BACKGROUND DENOTES EXISTING SURVEY FLOOR ELEVATIONS SECOND FLOOR - T.O. PLY. = 111'-0" (SITE = 7985'-11 1/4") FIRST FLOOR - T.O. PLY. = 100'-0" (SITE = 7974'-11 1/4") FIRST FLOOR OFFICE - T.O. PLY. = 99'-0" (SITE = 7973'-11 1/4") GARAGE - T.O. CONC. = 98'-0" (SITE = 7972'-11 1/4") CRAWL - T.O. CONC. = 93'-3 3/4" (SITE = 7967'-10 1/2") BASEMENT - T.O. PLY. = 89'-11 1/4" (SITE = 7966'-0") BASEMENT - T.O. PLY. = 88'-11 1/4" (SITE = 7965'-0") BASEMENT - T.O. PLY. = 87'-11 1/4" (SITE = 7964'-0") SET REBAR & CAP LS No. 38342 FOUND MONUMENT AS DESCRIBED SITE LEGEND EASEMENT FENCE PROPOERTY LINE EXISTING GRADE PROPOSED GRADE SETBACK LINE TREE TO BE RETAINED AS REQ'D TREE TO BE REMOVED TREE LEGEND EXISTING HOUSE CONCEPTUAL LOCATION AND FOOTPRINT OF PROPOSED HOUSE LIGHTING LEGEND 26.02 IN-GRADE LIGHT FIXTURE 26.03 RECESSED WALL LIGHT N TREE TABLE TRUNK DIAMETER IN INCHES, DRIPLINE IN FEET D = DECIDUOUS, C = CONIFER TREE #TREE TYPE DIAMETER DRIPLINE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 C D C C C C C C C C C C C C C C C C C C C C C C C C C C D D D D D D D D D D D D D D D D D D D D D D D 21 12 7 10 11 12 11 11 9 11 21 10 9 6 14 13 13 10 12 10 8 9 10 13 8 7 14 12 14 17 14 18 12 10 10 11 13 15 14 12 14 12 10 9 10 7 12 10 9 13 9 20 12 12 9 10 14 9 6 6 15 10 14 10 13 8 8 7 10 10 6 8 4 7 4 5 5 9 5 7 4 5 4 6 4 4 4 4 9 9 8 10 7 8 8 8 6 9 8 11 11 10 52 53 54 55 56 57 58 59 60 61 62 63 64 65 C C C C C C C C D D D D D D 10 13 12 9 9 12 11 14 8 14 9 11 9 14 9 14 9 11 10 11 10 14 11 9 8 7 11 810'10'25 '25'39'-5.5"1 2 3 4 5 6 7 8 1 0 1 1 2 3 2 2 2 4 2 5 2 6 2 7 2 8 2 9 3 0 3 3 3 2 3 1 9 1 2 1 3 1 4 2 0 1 8 1 9 1 5 1 7 1 6 2 1 3 7 5 0 4 9 4 8 4 7 4 6 4 5 4 4 4 3 4 2 4 1 4 0 3 9 3 8 3 6 3 5 3 4 5 2 5 4 5 6 5 5 6 5 6 3 6 4 5 1 5 3 5 8 6 0 5 9 6 2 5 7 83'-4.5" PARKING SPACE (TYP.) FIRE TRUCK TURNAROUND HOSE BIB HOSE BIB HOSE BIB HOSE BIB 2.01 26.02 26.02 26.02 26.03 26.03 26.03 26.03 26.03 32.04 32.04 32.04 32.04 26.02 26.02 26.02 26.02 26.02 26.02 26.02 26.03 26.03 32.02 32.02 32.02 32.02 32.05 35.02 32.02 32.02 32.02 AUTOCOURT OPEN NO FENCE ACCESS PROPERTY LINESIDE SETBACKREAR SETBACK FRONT SETBACK SIDE SETBACKPROPERTY L INE MIDLAND AVE CONCRETE SID E W A L K MECH ENCLOSURETRASH 7980798579807 98 0 7975797579707970 797 5 79 6 5 796 0 7 9 6 5 796 0 79 6 5 797 0 796 0 797 0 797 5 79857980 104 MIDLAND AVE 10'15'46 '-9 .5 "20'-10.5"NSCALE: 1" = 10'1Proposed Site Plan 0 5'10'20' THESE PLANS ARE CONCEPTUAL IN NATURE. INDIVIDUAL BUILDING PLANS MAY VARY BUT WILL BE EVALUATED FOR COMPLIANCE WITH DESIGN STANDARDS CONTAINED WITHIN SECTION 26.575.020 OF THE CITY OF ASPEN MUNICIPAL CODE AT THE TIME OF SUBMITTING A BUILDING PERMIT APPLICATION. Page 54 of 110 90247 PROPOSEDEXISTINGPage 55 of 110 91248 PROPOSEDEXISTINGPage 56 of 110 92249 PROPOSEDEXISTINGPage 57 of 110 93250 PROPOSEDEXISTINGPage 58 of 110 94251 PROPOSEDEXISTINGPage 59 of 110 95252 12 10 9 8 7 6 5 43 2 1 11 12 11 10 9 8 7 6 5 4 3 2 1MIDLAND AVENUEPage 60 of 110 96253 Exhibit E.1 Page 61 of 110 97254 Page 62 of 11098255 Page 63 of 110 99256 100257 Page 65 of 110 101258 September 12, 2022 Jay Engstrom Crystal River Civil LLC 1101 Village Rd UL-4C Carbondale, CO 81623 RE: 108 Midland Ave Dear Jay, The Aspen Consolidated Sanitation District currently has sufficient wastewater collection and treatment capacity to serve this project. Service is contingent upon compliance with the district’s rules, regulations, and specifications, which are on file at the District office. There are downstream constraints in the District’s collection system that will be corrected through a system of proportionate impact fees. A tap permit must be completed at our office when detailed plans become available. Fees will be estimated at that time. The total connection charges due the District must be paid prior to the issuance of a foundation and/or infrastructure permit. Existing service lines or laterals connected to the District’s main line, serving the subject property and adjacent properties must be identified, located and isolated from soil stabilization processes or other potential damage, or, properly disconnected from the ACSD main line at the point of connection according to specific ACSD requirements. Once detailed plans are made available to the district, we can comment specifically about this proposed project. Sincerely, Chip Strait Permit Technician CC Bruce Matherly, ACSD District Manager Exhibit G.1 Intent to Serve Letters Page 66 of 110 102259 Improving life with energy www.blackhillsenergy.com September, 13th 2022 Re: 108 Midland Ave Aspen, Co 81611 To whom it may concern: The above mentioned development is within the certificated service area of Black Hills Energy Black Hills Energy has existing natural gas facilities located on or near the above mentioned project. At this time it appears that these existing facilities have adequate capacity to provide natural gas service to your project, subject to the tariffs, rules and regulations on file. Any upgrading of our facilities necessary to deliver adequate service to and within the development will be undertaken by Black Hills Energy upon completion of appropriate contractual agreements and subject to necessary governmental approvals. Please contact us with any questions regarding this project, and with a timeline of when you would like to proceed with your project. Sincerely, Paul Ficklin Utility Construction Planner Black Hills Energy Glenwood Springs, Co Name Paul Ficklin Title: Utility Construction Planner paul.ficklin@blackhillscorp.com 580 Hwy 92 Delta, Co 81416 970-596-1122 Page 67 of 110 103260 Improving life with energy www.blackhillsenergy.com Page 68 of 110 104261 September 13, 2022 Jay Engstrom, P.E. Crystal River Civil LLC 1101 Village Road UL-4C Carbondale, Colorado 81623 Dear Jay: Subject: Residential Property Currently Addressed as: 108 Midland Avenue, Aspen, CO. City of Aspen Water Service In response to your recent request, this letter will serve as written verification that the City of Aspen Utilities Department currently has sufficient capacity to provide water to 108 Midland Avenue. This statement of capacity is valid for a period of 90 days from the date of this letter. Aspen makes no guarantee that it will have sufficient capacity to serve this lot if water service has not been initiated prior to the expiration of said five-year period. This letter does not represent a commitment to serve this property. To obtain water service to this property, the applicant will need to demonstrate full compliance with the requirements of the City Municipal Code and the Aspen Water Utility Standards. Due to the unknown age and condition of the service line, the developer may be required to abandon at the main water line and upsize the service line as necessary to serve this project. If you have need of additional information concerning City of Aspen water service, please do not hesitate to contact me at 970.920.5118. Sincerely, Justin Forman, P.E. Field Operations Manager City of Aspen Utilities Department justin.forman@aspen.gov Page 69 of 110 105262 3799 HIGHWAY 82∙P.O. BOX 2150 GLENWOOD SPRINGS, COLORADO 81602 (970) 945-5491∙FAX (970) 945-4081 A Touchstone Energy→ Cooperative September 12, 2022 Jay Engstrom, P.E. Crystal River Civil, LLC 970-404-1144 RE: 108 Midland Ave, Aspen The above mentioned development is within the certified service area of Holy Cross Energy. Holy Cross Energy has adequate power supply to provide electric power to the development, subject to tariffs, rules and regulations on file. Any power line enlargements, relocations, and new extensions necessary to deliver adequate power to and within the development will be undertaken by Holy Cross Energy upon completion of appropriate contractual agreements and subject to necessary governmental approvals. Please advise when you wish to proceed with the development of the electric system for this project. Sincerely, HOLY CROSS ENERGY Libby Cowling, Engineering Department lcowling@holycross.com (970) 947-5428 LC:MM Page 70 of 110 106263 108 Midland AvenueProposed Residence79607961 79627963796479657966796779687973 79727969797079717968 7972 797779787973797579767970 79727973 797579647967 79697968796679667965 79727972104 Midland AvenueExisting ResidenceMidland AvenueRight-Of-WayEast Cooper AvenueRight-Of-Way15' Open Space EasementBuilding EnvelopeProperty LineProposed 108 MidlandAvenue DrivewayProposed Regrading Of104 Midland Avenue DrivewayProposed Curb and Gutterand 5' SidewalkProposed AsphaltProposed Retaining WallsTo Minimize DisturbanceProposed Sand SetPervious WalkwayProposed Sand SetPervious PaversProposed Driveway RampGrass Paver Fire TruckTurnaroundDry Creek Landscape FeatureStormwater DrywellStormwater DrywellStormwater DrywellXCXCCCCXFOXFOFOFO<<FDFDXGXGGGGXSSXSSSSSSXUEXUEUEUEXOEXOEOEOEXTXTTTTXWXWWWWXWSXWSWSWSAbbreviations:ASTMAmerican Society of Testing and MaterialsAvg AverageBldg BuildingBMBenchmarkBMPBest Management PracticesBOW Bottom of WallCon ConcreteDemo DemolitionDia or ØDiameterDimDimensionEl or Elev ElevationExExistingFFEFinished Floor ElevationFLFlow LineFtFoot or FeetGal GallonsHoriz HorizontalHpHigh PointInvInvertLFLinear FeetLPLow PointMax MaximumMinMinimumNTS Not To ScaleOff OffsetPCPoint of Horizontal TangencyPCCPoint of Compound CurvePerf PerforatedPIPoint of Horizontal TangencyProp ProposedPVCPolyvinyl Chloride PipeQFlow RateRCPReinforced Concrete PipeROWRight-Of-WaySFSquare FeetSta StationSYSquare YardTDTrench DrainLegendExistingCommunications LineProposedEasement LineEdge of PavementEdge of GravelEdge of WaterFiber Optic LineFlow LineFoundation DrainGas LineGutter Flow Line / Break LineMajor Contour LineMinor Contour LineProperty LineSanitary Sewer LineStorm Drain LineConcrete / Sidewalk / PatioUnderground Electric LineOverhead Electric LineTelephone LineWater LineWater Service LineTOWTop of WallXRWXRWRWRWRaw Water LineDesign Notes1. The design is based on the best available information. This includes but is not limited to site conditions, features andstructures, and topographical information. Crystal River Civil is assuming no responsibility for the accuracy of site information.2.If any discrepancies or inaccurate information is found within Crystal River Civils' documents, the affected work should betemporarily put on hold. Contact CRC to verify a solution and hold all work until the necessary alterations have been made.3. No field changes are to occur without written approval of the engineer. If changes are requested and approved, Crystal RiverCivil will review the change and respond accordingly.Construction Notes1. All work completed on this project must meet standards set by the project's jurisdictions. This includes but is not limited toHOA standards, city/town standards, county standards, and/or state standards.2. The contractor is required to have a copy of current and approved construction plans. Any standards and specificationsnecessary for the work must be on site for the duration of the project as well.3. All work must be completed to horizontal and vertical information shown on the plans. If any changes have occurred, CrystalRiver Civil must verify the alterations prior to receiving approval of completion.4.Construction staking of horizontal and vertical layout is the responsibility of the Contractor. If additional documents, site visitsfor verification, or alterations are necessary, Crystal River Civil can be hired for construction administration for additionalservices.5. Property lines, monuments, benchmarks, survey control, and additional historic survey information cannot be removed andcannot be removed for construction. Disturbed survey items are the responsibility of the contractor and must be restored by astate of Colorado licensed land surveyor.6. Work and storage areas must be maintained only onsite. Project construction in Right-Of-Ways, public space, and privateproperty must be approved in writing by the necessary jurisdiction or individual.7. Limits of disturbance, tree protection, and slope protection defined within the plans must be met. Disturbances outside of theseextents may require alterations to the design and has implications that are the responsibility of the contractor. If damage shalloccur outside of these areas, the site conditions shall be restored to their original state.8.If applicable and a tree removal plan has been developed for the project, it is the responsibility of the contractor to meet theproposed conditions by the approved document. The contractor must not damage, trim, or remove trees and or bushes thatare not approved for modification by the tree removal plan. Approval for proceeding with additional tree removal must beapproved by Crystal River Civil, the landscape architect, the owner, and/or any stakeholders.9. The Contractor is responsible for removal of waste created onsite from construction. Waste material that does not meet therequirements for cannot be used for backfilling on the project and must be exported from the site.10. All materials requiring compaction must meet CDOT and/or ASTM Standards.11. If traffic control is needed for the project, it is the responsibility of the contractor to obtain and implement an approved trafficcontrol plan. Street access must be provided to the public within the Right-Of-Way - Any obstruction to general traffic flowmust be mitigated for. Pedestrian access must be always provided, and traffic entering and leaving the project site is to beobserved by the contractor.12. Dust mitigation must be provided by the contractor as necessary. Water shall be used as a dust palliative where and whenrequired. Sweeping and cleaning streets and sidewalks during the construction will be directed by the affected jurisdictions andperformed as necessary by the contractor.Utility Notes1. Utilities shown on these plans have been located and documented by the surveyor.2.Existing utilities must be verified on the site prior to construction. The contractor must protect and maintain these existingutilities throughout construction. If any damages occur to existing utility lines, it is the responsibility of the contractor tocoordinate with the utility provider replace and repair the utilities as necessary.3. The contractor must notify the utility providers a minimum of 3 days prior to any work completed. Coordination with the utilityproviders is the responsibility of the contractor.4. All utility work completed by the contractor must be installed as per the utility providers' standards and requirements.Inspections must be performed by utility providers as deemed necessary by the corresponding standards. It is theresponsibility of the contractor to organize these inspections.5.If any shallow utilities, including communication and telephone services and lines, are exposed, and temporarily altered forconstruction, the reinstallation of these utilities must conform with the utility providers standards.6. Uncovered gas lines must be temporarily contained with 18 inches backfill to minimize exposure.7. Stormwater infrastructure must pe protected by the contractor as shown in the Erosion Control Plan. During construction,additional stormwater management may be necessary during specific construction procedures and is the responsibility of thecontractor.040NSW EDrawing ScaleUnits (Feet) 1" = 20'20Vicinity MapNot to ScaleSite108 Midland AvenueAspen CO, 81611Of 11 Pages01 Council Review Drawings 12.23.2022 JKE #Description Date Drawn By 108 Midland Avenue Aspen, Colorado, 81611 1101 Village Road, Unit UL-4CCarbondale, CO 81623(970) 510 - 5312VJT Reviewed By Not For ConstructionJob #: 22.07C.01Title And NotesSheet List TableSheet NumberSheet TitleC.01Title And NotesC.02Existing ConditionsC.03Existing Conditions Steep Slope AnalysisC.04Platted Steep Slope AnalysisC.05Demolition PlanC.06Utility PlanC.07Basin Analysis And Drainage DesignC.08108 Midland Driveway Plan and ProfileC.09104 Midland Driveway Plan and ProfileC.10Grading And DrainageC.11Right-Of-Way Plan and ProfilePage 71 of 110107264 108265 0+70.00 1+30.00 D DDD<Area Within Right-Of-Way To Be Impacted57 Square FeetSteep Slopes Not To Be ImpactedSteep Slopes On 104 MidlandAvenue To Be Impacted985 Square FeetSteep Slopes On 104 MidlandAvenue Not To Be ImpactedSteep Slopes From Pond Removed FromSite Due To Pond Removal ProcessSteep Slopes On SiteTo Be Impacted343 Square FeetSteep Slopes From RetainingWall To RemainSteep Slopes Not To Be ImpactedProperty Line (Typ)Setback Line (Typ)Edge Of ExistingDrivewayEdge Of Existing DrivewayFor 104 Midland AvenueMidland Avenue79617963796579687970797279737 9 7 8 7966 798679 8 5 796079657970797579777975 7979 79707965798079827985797279607961796279637964796579667967 7968 79737972 7969 7970 797179687972797779787973797579767970 7972797379757964796779697968796679667965 7 9 7 2 7972Steep Slopes On SiteTo Be Impacted208 Square FeetSteep Slopes On SiteTo Be Impacted421 Square FeetSteep Slopes On SiteTo Be Impacted40 Square FeetOf 11 Pages01 Council Review Drawings 12.23.2022 JKE #Description Date Drawn By 108 Midland Avenue Aspen, Colorado, 81611 1101 Village Road, Unit UL-4CCarbondale, CO 81623(970) 510 - 5312VJT Reviewed By Not For ConstructionJob #: 22.07Drawing ScaleUnits (Feet) 1" = 10'1020NSWE0= 30% Steep Slope Area Not To Be Impacted= 30% Steep Slope Area Onsite To Be Impacted= 30% Steep Slope Area Offsite To Be ImpactedNote: 30% Steep Slope Areas Represented In TheseDrawings Have Been Designated By The Surveyor108 Midland AvenueProposed ResidenceC.03Existing ConditionsSteep Slope AnalysisPage 73 of 110109266 D DDSXSSXSSXSSD<Steep Slopes Not To Be ImpactedSteep Slopes On NeighboringProperty To Be Impacted632 Square FeetSteep Slopes On SiteTo Be Impacted81 Square FeetProperty Line (Typ)Setback Line (Typ)Edge Of Existing DrivewayEdge Of Existing DrivewayFor Neighboring ResidencePlatted 30% Slope AreaBook 11 Page 59Steep Slopes In Right-Of-WayTo Be Impacted82 Square FeetSteep Slopes Not To Be Impacted79617963796579687970797279737 9 7 8 7966 798679 8 5 796079657970797579777975 7979 79707965798079827985797279607961796279637964796579667967 7968 79737972 7969 7970 797179687972797779787973797579767970 7972797379757964796779697968796679667965 7 9 7 2 7972Steep Slopes On SiteTo Be Impacted2,734 Square FeetOf 11 Pages01 Council Review Drawings 12.23.2022 JKE #Description Date Drawn By 108 Midland Avenue Aspen, Colorado, 81611 1101 Village Road, Unit UL-4CCarbondale, CO 81623(970) 510 - 5312VJT Reviewed By Not For ConstructionJob #: 22.07Drawing ScaleUnits (Feet) 1" = 10'1020NSWE0= 30% Steep Slope Area Not To Be Impacted= 30% Steep Slope Area Onsite To Be Impacted= 30% Steep Slope Area Offsite To Be ImpactedNote: 30% Steep Slope Areas Represented In TheseDrawings Have Been Designated By The Surveyor108 Midland AvenueProposed ResidenceC.04Platted SteepSlope AnalysisPage 74 of 110110267 D XTXTXTXTXTXTXTXTXTXTXTXTXTXTXTXTXTXTXTXTXTXTXTXTXTXTXTXTXTEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEGTCXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWXWXWXWXWXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXCXCXCXCXCXCXCXCXCXCXCXCXCXCXCXCXCXCXCXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGESXSSXSSXSSTCEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXCXCXCXCXCXCXCXCXCXCXCXCXCXCXCXCXCXCXCXCTEDXSSXSSXSSXSSXSSXSSXSSXSSXSSXSSXSSXSSXSSXSSXSS<79617963796579687970797279737 9 7 8 7966 798679 8 5 796079657970797579777975 7979 797079657980798279857972Abandon Existing Water Service Tap For 108 Midland AvenueVerify Abandonment Of Old 104 Midland Avenue ServiceAs Per City of Aspen Water District Standards.Contact City Of Aspen Prior To AbandonmentAbandon Existing Water Service Tap For 104 Midland AvenueAs Per City of Aspen Water Department Standards.Contact City Of Aspen Prior to AbandonmentCommunications Service for 104 MidlandTo Be Lowered During DrivewayReconstruction To Meet UtilityProvider Requirements102 Linear FeetBlack Hills Energy Natural Gas Service for 104 MidlandTo Be Realigned And Lowered During DrivewayReconstruction To Meet UtilityProvider Requirements75 Linear FeetBlack Hills Energy Natural Gas Service for 108 MidlandTo Be Realigned And Lowered During DrivewayReconstruction To Meet UtilityProvider Requirements100 Linear FeetRemove or Abandon Existing WaterService For 104 Midland Avenue85 Linear FeetRemove or Abandon Existing WaterService For 104 Midland Avenue250 Linear FeetRemove Or Abandon TelephoneService for 108 Midland88 Linear FeetRemove Or Abandon ElectricalService for 108 Midland94 Linear FeetRemove CommunicationsService for 108 Midland105 Linear FeetRemove Sewer Servicefor 108 Midland88 Linear FeetRepair And Service Sewer ManholeAs Necessary For New Service Tie-InAs Per ACSD StandardsMill 2' of Existing Asphalt Along Sawcut546 Square FeetSawcut AsphaltLayout Shown on Right-Of-WayPlan and Profile Sheet270 Linear FeetRemove Existing Asphalt2,026 Square FeetDemolish Existing Sidewalk and Curb and Gutter165 Linear FeetRemove Existing Concrete Driveway5,710 Square FeetGrub and Prep Area For Improvements2,160 Square FeetSawcut AsphaltLayout Shown on Right-Of-WayPlan and Profile Sheet24 Linear FeetMill 2' of Existing Asphalt Along Sawcut24 Square FeetRemove Existing Asphalt36 Square FeetGrub and Prep Area For Improvements3,801 Square FeetDemolish ImprovementsAround Existing Residence575 Square FeetDemolish Existing ResidenceNote: For Tree Removal Information, See Tree Mitigation PlanRemove Abandoned Utilities As NecessaryFor Installation Of Proposed InfrastructureOf 11 Pages01 Council Review Drawings 12.23.2022 JKE #Description Date Drawn By 108 Midland Avenue Aspen, Colorado, 81611 1101 Village Road, Unit UL-4CCarbondale, CO 81623(970) 510 - 5312VJT Reviewed By Not For ConstructionJob #: 22.07Drawing ScaleUnits (Feet) 1" = 10'1020NSWE0C.05Demolition PlanPage 75 of 110111268 D DDXTXTXTXTXTXTXTXTXTXTXTXTXTXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEGXWXWXWXWXWXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGESXSSXSSXSSTCEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOETEDWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSCCCCCCCCCCCCCCCCCCCCCGGGGGGGGGGGGGGGGGGGGGGGGGSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSTTTTTTTTTTTTTTTTTTTTUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEOC<79617963796579687970797279737 9 7 8 7966 798679 8 5 796079657970797579777975 7979 79707965798079827985797279607961796279637964 7965 7966 7967 7968 79737972 7969 7970 797179687972797779787973797579767970 7972797379757964796779697968796679667965 7 9 7 2 7972Install 2" Water Service Tap As PerCity Of Aspen Water Department StandardsMaintain 18" of Separation Between All Fittings2-Way Sewer CleanoutWithin 5' of Structure45° Bends103± Linear Feet of 4" SDR-26Gravity Sanitary Sewer Service LineMaintain Min. 5 Feet Of Cover Over Pipe100± Linear Feet Electric ServiceWithin 2" Conduit As Per CityOf Aspen Electric Standards97± Linear Feet Telecom ServiceWithin 2" Conduit As PerUtility Provider Standards208± Linear Feet GasService For 108 MidlandLine Material and SizePer Black Hills EnergyRequirements128± Linear Feet GasService Realignment AndExtension For 104 MidlandLine Material and SizePer Black Hills EnergyRequirementsTie Into Existing Sewer ManholeGrout and Seal Pipe Into ManholeAs Per ACSD Standards188± Linear Feet 2" Type K CopperWater Service From Curb Stop ToWater Meter For 108 Midland97± Linear Feet Type K CopperWater Service From Curb Stop ToWater Meter For 104 MidlandMatch Size of ExistingWater Service105± Linear Feet Telecom ServiceWithin 2" Conduit As PerUtility Provider StandardsCommunications PedestalInstall Water Service Tap As PerCity Of Aspen Water Department StandardsSize Service To Match Existing TapMaintain 18" SeparationBetween All Fittings12± Linear Feet Type K CopperWater Service From Tap ToCurb Stop For 104 MidlandMatch Size of ExistingWater ServiceInstall Curb Stops For104 And 108 Midland AvenueTie Into Existing Service12± Linear Feet 2" Type K CopperWater Service From Tap ToCurb Stop For 104 MidlandCurb Stop Every 100Feet Of ServiceGas MeterBlack Hills Energy GasService TapsTelephone PedestalHoly Cross Electric TransformerVerify Capacity Prior To ConstructionVerify and MaintainSeparation RequirementsFor All Utility CrossingsOf 11 Pages01 Council Review Drawings 12.23.2022 JKE #Description Date Drawn By 108 Midland Avenue Aspen, Colorado, 81611 1101 Village Road, Unit UL-4CCarbondale, CO 81623(970) 510 - 5312VJT Reviewed By Not For ConstructionJob #: 22.07Drawing ScaleUnits (Feet) 1" = 10'1020NSWE0C.06Utility PlanPage 76 of 110112269 D DDXTXTXTXTXTXTXTXTXTXTXTXTXTEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXWXWXWXWXWDSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSTTTTTTTTTTTTTTTTTTUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEXSSXSSXSSXSSXSSXSSXSSXSSXSSXSSXSSXSSOC<79617963796579687970797279737 9 7 8 7966 798679 8 5 796079657970797579777975 7979 79707965798079827985797279607961796279637964796579667967 7968 79737972 7969 7970 797179687972797779787973797579767970 7972797379757964796779697968796679667965 7 9 7 2 7972Additional Stormwater Design For 108 MidlandAvenue To Be Provided for Permit Set SubmittalExisting Drywell Collects StormwaterIn Autocourt For 104 Midland Avenue35,945 Sq Ft56.5% Imp.Trench Drain With Catch BasinTies Directly To Drywell25,736 Sq Ft78.4% Imp.12,669 Sq Ft68.2% Imp.DownspoutsDownspoutDownspoutDownspoutDownspoutTrench DrainTrench DrainDrywell 14' Diameter 12' Deep10' Deep of Capacity193 Cubic Feet of DetentionSized For Full Detention ofa 100-Year 1-Hour Storm EventDrywell 26' Diameter 17' Deep15' Deep of Capacity488 Cubic Feet of DetentionSized For Full Detention ofa 100-Year 1-Hour Storm EventDriveway Drywell6' Diameter 12' Deep10' Deep of Capacity350 Cubic Feet of DetentionSized For Full Detention ofa 100-Year 1-Hour Storm EventInletOf 11 Pages01 Council Review Drawings 12.23.2022 JKE #Description Date Drawn By 108 Midland Avenue Aspen, Colorado, 81611 1101 Village Road, Unit UL-4CCarbondale, CO 81623(970) 510 - 5312VJT Reviewed By Not For ConstructionJob #: 22.07Drawing ScaleUnits (Feet) 1" = 10'1020NSWE0C.07Basin Analysis And DrainageDesignPage 77 of 110113270 XWXWXWXWXWDC<0+70.00 1+30.00 D D108 MidlandProposed ResidenceStart Driveway60° Angle Off Curb and GutterSta:0+09.54Off:0.00'0 00 1 00 2 00 2 08PC: 0+15.69PC: 1+24.61PC: 0+70.16PT: 0+50.61PT: 1+39.07PT: 1+00.91Start 108 Midland Driveway AlignmentSTA:0+00.00N:5012.28E:4605.02End 108 Midland Driveway AlignmentSTA:2+07.75N:5151.14E:4742.47Curb And Gutter Flow LineSta:0+05.01Off:8.00'RElev:7960.03Edge Of PavementSta:0+09.77Off:10.75'RElev:7960.15Curb And Gutter Flow LineSta:0+15.89Off:11.12'LElev:7959.12Edge Of PavementSta:0+21.96Off:8.00'LElev:7959.23Start Driveway Seperation TransitionSta:0+43.05Off:8.06'RElev:7962.0330" Boulder WallSta:0+55.04Off:8.00'RElev:7963.01Start 30" Boulder WallSta:0+75.49Off:7.99'LElev:7965.05End 30" Boulder WallStart Concrete WallSta:1+48.44Off:7.50'LElev:7970.35796179637965796879707972797379 7 8 7966 79867985 7960796579707975797779757979797079657980798279857972Tiered 30" Boulder WallSta:1+18.09Off:12.50'RElev:7971.96End Tiered 30" Boulder WallStart Concrete WallSta:1+50.74Off:36.00'RElev:7971.76Concrete WallSta:1+50.74Off:58.34'RElev:7972.36Concrete WallSta:1+84.06Off:62.38'RElev:7972.97Edge of PavementTrench DrainSta:1+67.23Off:32.72'RElev:7972.16L4L1L2L3C1C3C216.0'Edge of PavementSta:2+02.75Off:7.50'LElev:7972.8330" Boulder WallSta:1+33.27Off:9.22'RElev:7969.6530" Boulder WallSta:1+24.61Off:8.00'RElev:7969.26R30'R30'Edge of PavementSta:1+96.75Off:8.50'RElev:7972.63Edge of PavementSta:2+02.75Off:8.50'RElev:7972.8730" Boulder WallSta:0+51.74Off:16.76'RElev:7963.86Edge Of PavementSta:0+19.33Off:12.31'RElev:7960.47Edge Of PavementSta:0+38.98Off:21.22'RElev:7962.77For Driveway RampSee City Of Aspen DetailOn Sheet C.01610.0%4.6%3.9%5.0%2.0%12.0%See 104 Midland Driveway PlanAnd Profile For Additional InformationEnd Tiered 30"Boulder WallSta:1+46.25Off:36.00'RElev:7974.213'3'6'9'Series of 30" CortenRetaining WallsFire Truck Turning RadiusFrom East CooperOnto DrivewayGrass PaverFire TruckTurnaround108 MidlandConcreteDriveway104 MidlandConcreteDriveway3'For Right-Of-Way ImprovementsSee Sheet C.013-C.015ProposedAsphaltProposed S idewa lkWi th Curb and Gu t ter Trench DrainSta:1+63.92Off:59.94'RElev:7972.360.0%2.6%Ex:83.36Ex:85.21Ex:82.52Ex:82.59Ex:78.53Ex:79.2272.85Ex:76.80Ex:79.13Ex:78.23Ex:83.71End DrivewaySta:2+02.753.0:13.0:1 72.8571.4675.1572.6572.1576.7177.5477.5473.7276.3176.3176.8176.8180.3180.3168.9671.4668.9665.5566.1968.6968.4465.9465.5165.7172.9773.0073.00Trench DrainSta:1+39.87Off:13.42'RElev:7970.21Trench DrainSta:1+39.87Off:8.00'LElev:7969.96Trench DrainSta:0+42.64Off:7.90'RElev:7962.00Trench DrainSta:0+42.35Off:8.00'LElev:7961.49Trench DrainSta:0+37.26Off:19.76'RElev:7962.407960796 1 7962 7963 7964 7965 7966 7967 7968 797379727969 79707971796879727977797879737 9 7 5 797679707972797379757 9 6 4 7 9 6 7 7 9 6 9 79 6 8 7 9 6 6 79 6 6 7 9 6 5 797 2 7972Midland AvenueRight-Of-WayEast Cooper AvenueRight-Of-WayDrywellSta:0+45.04Off:8.78'RNote: Drainage Stormwater System for 108Midland Avenue to be completed for Permit Set7 9 7 3 7974Edge of PavementTrench DrainSta:1+72.87Off:20.34'RElev:7971.82Edge of PavementTrench DrainSta:1+75.09Off:1.13'RElev:7971.57Edge of PavementTrench DrainSta:1+67.72Off:7.50'LElev:7971.23Edge of PavementTrench DrainSta:1+53.64Off:5.35'LElev:7970.59108 Midland Driveway Alignment ProfileHorizontal Scale: 1"=10'Vertical Scale: 1"=10'795579607970798079557960797079800+20EG 7960.6 FG 7959.610+40EG 7962.9 FG 7961.500+60EG 7966.1 FG 7963.500+80EG 7969.8 FG 7965.50 1+00EG 7972.5 FG 7967.50 1+20EG 7975.3 FG 7969.05 1+40EG 7976.8 FG 7969.96 1+60EG 7978.1 FG 7970.88 1+80EG 7978.3 FG 7971.79 2+00EG 7979.4 FG 7972.71 -0.63%10.00%4.58%Start Driveway Sta = 0+09.54Elev = 7959.570GRADE BREAK STA = 2+02.75ELEV = 7972.834LOW PT STA: 0+16.48LOW PT ELEV: 7959.53PVI STA:0+20.00PVI ELEV:7959.50K:0.75LVC:8.00BVCS: 0+16.00BVCE: 7959.53EVCS: 0+24.00EVCE: 7959.90HIGH PT STA: 1+16.99HIGH PT ELEV: 7968.91PVI STA:1+11.57PVI ELEV:7968.66K:2.00LVC:10.85BVCS: 1+06.15BVCE: 7968.12EVCS: 1+16.99EVCE: 7968.91Edge of Open Space Easement108 MidlandProperty LineSetback LineExisting Driveway GradeProposed Driveway GradeSta:0+15.86Elev:7959.53104 Midland Property Line0+70.0079557960796579707975-20 -15 -10 -5 0 5 10 15 20Edge of DriveOff=-8.00El=7964.50Edge of DriveOff=8.00El=7964.50Top of WallOff=9.51El=7967.01Existing GradeProposed Grade1+30.00796079657970797579807985-20 -15 -10 -5 0 5 10 15 20 25 30Existing GradeProposed GradeTop Of WallOff=-9.50El=7972.00Edge of RoadOff=8.47El=7969.50Top Of WallOff=9.98El=7972.01Top Of WallOff=14.53El=7975.03Edge of RoadOff=-8.00El=7969.50Bottom Of WallOff=12.99El=7972.52Line TableLineL1L2L3L4BearingS87°45'51"EN39°35'14"EN48°23'51"EN26°35'14"ELength15.69'19.54'23.70'68.67'Start Point (N,E)5012.28,4605.025025.43,4651.475062.59,4685.275089.73,4711.74End Point (N,E)5011.67,4620.705040.49,4663.935078.33,4702.995151.14,4742.47Curve TableCurveC1C2C3Radius38.00'200.00'38.00'Length34.92'30.75'14.47'Tangent18.80'15.41'7.32'Chord33.70'30.72'14.38'BearingN65°54'41"EN43°59'32"EN37°29'32"EDelta52° 38' 56"8° 48' 37"21° 48' 37"Of 11 Pages01 Council Review Drawings 12.23.2022 JKE #Description Date Drawn By 108 Midland Avenue Aspen, Colorado, 81611 1101 Village Road, Unit UL-4CCarbondale, CO 81623(970) 510 - 5312VJT Reviewed By Not For ConstructionJob #: 22.07Drawing ScaleUnits (Feet) 1" = 10'1020NSWE0C.08108 Midland DrivewayPlan and ProfilePage 78 of 110114271 DD 100 00 101 00 101 25 PC: 100+12.31PC: 100+65.59PT: 100+35.08PT: 101+07.77Start 104 Midland Driveway AlignmentSTA:100+00.00N:5018.43E:4607.42End 104 Midland Driveway AlignmentSTA:101+25.00N:5035.33E:4720.817961796379657968797079727966 7972108 MidlandConcreteDriveway104 MidlandConcreteDrivewayProposedAsphaltProposed S idewa lkWi th Curb and Gu t ter796079 6 1 7962 7963 7964 7965 7966 7967 7968 7969 79707968797279737 9 7 5 79767970797279737 9 6 4 79 6 7 7 9 6 9 79 6 8 7 9 6 6 79 6 6 7 9 6 5 7972Edge Of PavementSta:100+14.39Off:11.11'RElev:7960.15Start DrivewaySta:100+09.50Off:0.00'Elev:7959.48Edge Of PavementSta:100+22.78Off:8.65'RElev:7960.47Edge Of PavementSta:100+49.59Off:7.04'RElev:7962.77Edge Of PavementSta:100+49.95Off:8.89'RElev:7962.81Trench DrainSta:100+46.50Off:7.05'RElev:7962.40Trench DrainSta:100+46.50Off:6.87'LElev:7962.00Edge Of Driveway TransitionSta:100+47.00Off:7.03'LElev:7962.03Edge Of PavementBottom Of WallSta:100+60.99Off:8.18'LElev:7963.86Edge Of PavementSta:100+74.37Off:7.97'RElev:7965.88Edge Of PavementSta:100+90.07Off:11.70'RElev:7968.13Edge Of PavementSta:100+99.41Off:12.15'RElev:7969.20Edge Of PavementSta:100+14.39Off:11.11'RElev:7960.15Edge Of PavementSta:100+14.39Off:11.11'RElev:7960.15Tie Into Existing ConcreteSta:101+14.93Off:13.54'LElev:7968.95Tie Into Existing ConcreteSta:101+21.17Off:10.25'RElev:7969.03Existing DrywellSta:101+23.55Off:3.99'LElev:7969.36L5 L6L7C4C5Edge Of PavementSta:100+16.08Off:10.85'LElev:7959.23Edge Of PavementSta:100+74.85Off:9.39'LElev:7965.53R45'Bottom Of WallSta:100+56.72Off:16.50'LElev:7963.0165.71Ex:66.83Ex:69.4216.5'Replace Existing Rock WallsTo Transition To Existing GradeMax 30" Boulder Wall12.0%1.5%2.0% 1. 0% 3.0%Property Line (Typ)Property Line (Typ)15' Open Space EasementMidland AvenueRight-Of-WayEast Cooper AvenueRight-Of-WayDrywellSta:100+49.34Off:8.04'L104 Midland Driveway Alignment ProfileHorizontal Scale: 1"=10'Vertical Scale: 1"=10'795579607970795579607970100+20EG 7960.8 FG 7959.79 100+40EG 7963.3 FG 7961.70 100+60EG 7965.4 FG 7964.10 100+80EG 7967.7 FG 7966.50 101+00EG FG 7968.74 101+20EG FG -2.00%2.00%4.00%12.00%PVI STA: 100+26.14PVI ELEV: 7960.04K: 1.50LVC: 12.00BVCS: 100+20.14 BVCE: 7959.80 EVCS: 100+32.14 EVCE: 7960.76 PVI STA: 101+03.47PVI ELEV: 7969.32K: 1.50LVC: 21.00BVCS: 100+92.98 BVCE: 7968.06 EVCS: 101+13.97 EVCE: 7969.11HIGH PT. STA: 101+10.97HIGH PT ELEV: 7969.14START DRIVEWAY STA = 100+09.50ELEV = 7959.483TIE INTO EXISTING DRIVEWAYSTA = 101+18.48ELEV = 7969.016104 Midland Property LineLine TableLineL5L6L7BearingS58°14'13"EN87°26'17"EN47°09'04"ELength12.31'30.51'17.23'Start Point (N,E)5018.43,4607.425006.30,4639.595023.61,4708.18End Point (N,E)5011.95,4617.895007.66,4670.065035.33,4720.81Curve TableCurveC4C5Radius38.00'60.00'Length22.77'42.19'Tangent11.74'22.01'Chord22.43'41.32'BearingS75°23'58"EN67°17'40"EDelta34° 19' 30"40° 17' 13"Of 11 Pages01 Council Review Drawings 12.23.2022 JKE #Description Date Drawn By 108 Midland Avenue Aspen, Colorado, 81611 1101 Village Road, Unit UL-4CCarbondale, CO 81623(970) 510 - 5312VJT Reviewed By Not For ConstructionJob #: 22.07Drawing ScaleUnits (Feet) 1" = 10'1020NSWE0C.09104 Midland DrivewayPlan and ProfilePage 79 of 110115272 XTXTXTXTXTXTXTXTXTXTXTXTXTXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEGXWSXWSXWSXWXWXWXWXWXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGESXSSXSSXSSTCEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOETEDWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSCCCCCCCCCCCCCCCCCCCCCGGGGGGGGGGGGGGGGGGGGGGGGGSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSTTTTTTTTTTTTTTTTTTTTUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEOC<0+70.00 1+30.00 D DD108 MidlandProposed Residence10.0%3.0:1 3.0%10.0%4.6%5.9%79617963796579687970797279737 9 7 8 7966 798679 8 5 796079657970797579777975 7979 797079657980798279857972Grass PaverFire TruckTurnaround108 MidlandConcreteDriveway104 MidlandConcreteDrivewayProposedAsphaltProposed SidewalkWith Curb and Gutter79607961796279637964 7965 7966 7967 7968 79737972 7969 7970 797179687972797779787973797579767970 7972797379757964796779697968796679667965 7 9 7 2 7972Midland AvenueRight-Of-WayEast Cooper AvenueRight-Of-Way73.0072.9772.35TD:72.36BOW:72.9773.003.1%3.9%3.4%5.0% 2.6%BOW:72.3671.7676.3176.3176.8176.8174.2173.7279.3179.3179.3179.0076.7177.5477.5478.5380.31Ex:82.5980.31Ex:82.52TOW:85.21TOW:83.68TOW:83.36Corten Retaining WallsMax. 30" Tall With 3' StepsVarying Boulder AndCorten Retaining WallsMax. 30" Tall With 3' StepsBOW:63.01TOW:65.51BOW:64.52TOW:67.02BOW:67.59TOW:70.09BOW:68.96TOW:71.46BOW:71.96TOW:72.85BOW:69.65TOW:72.15BOW:72.65TOW:75.15BOW:63.84TOW:65.71BOW:65.87TOW:67.21BOW:68.95TOW:???BOW:65.56TOW:65.05BOW:70.09TOW:67.59BOW:71.42TOW:68.92BOW:72.50TOW:70.00TD:72.16BOW:78.24TOW:71.09BOW:79.21TOW:72.8372.8760.1559.230.7%69.0368.132.0%Note: Drainage Stormwater System for 108Midland Avenue to be completed for Permit Set71.8973.0773.6274.79EntryF.F.75.002.0%2.8%1.8%7973797 42 - 7" Steps2 - 7" StepsWater FeaturePerviousPavers71.8271.5771.5371.2370.5971.104.6%Stormwater DrywellStormwater DrywellPervious Paver Access Walkwaywith Bike RampUtility AreaDry Creek Landscape FeatureOf 11 Pages01 Council Review Drawings 12.23.2022 JKE #Description Date Drawn By 108 Midland Avenue Aspen, Colorado, 81611 1101 Village Road, Unit UL-4CCarbondale, CO 81623(970) 510 - 5312VJT Reviewed By Not For ConstructionJob #: 22.07Drawing ScaleUnits (Feet) 1" = 10'1020NSWE0C.10Grading And DrainagePage 80 of 110116273 XTXTXTXTXTXTXTXTXTXTXTXTXTXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEGXWSXWSXWSXWXWXWXWXWXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGESXSSXSSXSSTCEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOETEWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGWSWSWSWSWSWSWSWSWSWSWSWSCCCCCCCCCGGGGGGGGGGGGGGGSSSSSSSSSSSSSSSSSSSSSSSSSSSSTTTTTTTTTTTTTTUEUEUEUEUEUEUEUEUEUEUEUEUE<D 200+40.00200+50.00200+60.00200+70.00200+80.00200+90.00201+00.00 201+10.00 201+20.00 201+30.00 201+40.00 201+50.00 201+60.00 201+70.00 201+80.00 201+90.00 202+00.00 202+10.00 202+20.00 202+30.00 202+40.00 202+50.00 202+60.00 202+70.00 202+80.0 0 202+90.0 010.0%10.0%5.0%4.6%79617963796579687970797279737 9 7 8 7966 796079657970797579777975 7979 7970796579607961796279637964 7965 7966 7967 7968 7972 7969 7970 797179687970 79727973797579647966 200 00 201 00 202 00 202 97 PC: 200+64.13PC: 202+37.17PT: 202+16.41Start Flow Line AlignmentSTA:200+00.00N:4966.00E:4586.12End Flow Line AlignmentSTA:202+97.30N:5229.37E:4722.78L8L9C6C7Proposed Asphalt with 2' MillSta:200+01.57Off:28.13'RProposed Asphalt with 2' MillSta:200+11.56Off:28.56'RProposed Asphalt with 2' MillSta:200+01.14Off:38.12'RProposed Asphalt with 2' MillSta:200+11.13Off:38.55'RReplace Asphalt FromWater Line WorkProposed Asphalt with 2' MillSta:200+36.10Off:12.01'LProposed Asphalt with 2' MillSta:200+36.10Off:2.00'LStart Curb and Gutter0% Slope Into Flow LineSta:200+38.10Off:0.00'LElev:7960.375' Attached SidewalkSta:200+38.10Off:0.50'RElev:7960.605' Attached SidewalkSta:200+38.10Off:5.50'RElev:7960.708.3%Driveway RampSta:200+44.81Off:0.00'RElev:7960.03Driveway RampSta:200+44.75Off:5.47'RElev:7960.15Driveway RampSta:200+66.78Off:0.00'RElev:7959.12Driveway RampSta:200+66.76Off:5.50'RElev:7959.23Curb and GutterStart Transition From0% Slope Into Flow LineTo 8.33% Slope Into Flow LineSta:200+72.78Off:0.00'RElev:7959.085' Attached SidewalkSta:200+72.77Off:0.50'RElev:7959.565' Attached SidewalkSta:200+72.74Off:5.50'RElev:7959.66Start 18" Boulder WallSta:200+71.41Off:5.50'RElev:7959.575.0%5.0%1.0%1.0%Proposed Driveway RampSee Detail2.0%7.2%2.0%2.0%Curb and GutterEnd Transition From0% Slope Into Flow LineTo 8.33% Slope Into Flow LineSta:200+90.00Off:0.05'LElev:7958.89End 18" Boulder WallSta:202+75.50Off:5.50'REnd Curb and GutterSta:202+92.59Off:0.00'Elev:7956.865' Attached SidewalkSta:202+92.59Off:0.50'RElev:7957.365' Attached SidewalkSta:202+92.59Off:5.50'RElev:7957.463.8%2.3%1.1%1.6%1.7%0.4%0.7%0.7%2.7%3.5%1.3%0.9%2.4% 1.9% 1.1% 0.9% 2.2% 4.5% 6.5% 2.6% 1.7% 0.6% 0.7%0.1%3.2%3.8%1.0%1.0%1.0%1.0%2.0% 2.0% 2.0% 2.0% 2.0%4.6%Note: Sections To Be Completed for Permit Set.Flow Line Alignment ProfileHorizontal Scale: 1"=10'Vertical Scale: 1"=10'7950796079507960200+20EG FG200+40EG 7960.2 FG 7960.25200+60EG 7959.2 FG 7959.18200+80EG 7959.0 FG 7959.04201+00EG 7959.4 FG 7959.42 201+20EG 7958.3 FG 7958.28 201+40EG 7958.6 FG 7958.60 201+60EG 7958.1 FG 7958.07 201+80EG 7958.1 FG 7958.13 202+00EG 7957.9 FG 7957.92 202+20EG 7957.8 FG 7957.78 202+40EG 7957.6 FG 7957.59 202+60EG 7957.3 FG 7957.34 202+80EG 7957.0 FG 7956.97 -5.00%-1.00%GRADE BREAK STA = 200+38.10ELEV = 7960.367 GRADE BREAK STA = 202+92.59 ELEV = 7956.860 Of 11 Pages01 Council Review Drawings 12.23.2022 JKE #Description Date Drawn By 108 Midland Avenue Aspen, Colorado, 81611 1101 Village Road, Unit UL-4CCarbondale, CO 81623(970) 510 - 5312VJT Reviewed By Not For ConstructionJob #: 22.07Drawing ScaleUnits (Feet) 1" = 10'1020NSWE0C.11Right-Of-Way Plan and ProfilePage 81 of 110117274 Crystal River Civil LLC 970.510.5312 Page 1 of 5 108 Midland Avenue Engineering Memo January 23, 2023 Existing Conditions The property addressed as 108 Midland Avenue in Aspen, CO 81611 is defined as Lot 1 of the Ferguson Exemption Subdivision, or parcel #273718126110. The parcel is located to the east of downtown Aspen. This property is situated with Midland Avenue to the west and residential homes on the southern and eastern property border. To the north of the property is an open space parcel that is owned by the City of Aspen. Shown above is an image of the Pitkin County GIS Map displaying the location of 108 Midland Avenue The existing conditions of the property under evaluation include a single-family residence with a asphalt paved driveway, patio spaces, and landscaping. The existing home sits in the center of the property, with the driveway access approaching the house from the southern property line. The site generally slopes from the east to the west, with steep grades along the western property line. The existing vegetation includes pines, aspen trees, and brush surrounding the site. All the described conditions can be seen on the Existing Conditions sheet (C.02) of the submitted civil drawings. The following topics discuss in further depth the access, utilities, stormwater, and the natural and manmade hazards on the site: Exhibit G.3 Page 82 of 110 118275 Crystal River Civil LLC 970.510.5312 Page 2 of 5 Access: The driveway curb cut for the site is shared with the neighboring residence to the south, 104 Midland. The driveway starts on the southwest corner of the neighbor’s property and immediately splits into each individual drive, with the 108 Midland driveway extending to the northeast. It continues onto the property, levels out in grade for a parking area, and ties into the existing garage within the residence. The finish floor of the garage is over 20 feet higher than the Right-Of-Way below, therefore the 200-foot-long driveway has steep grades that exceed 16 percent. The narrowest part of the access is around twelve feet wide, and existing trees and foliage have grown into the driveway limiting clearances even further. Crystal River Civil met with the Aspen Fire Protection District onsite to discuss the access onto the property, and the existing conditions do not meet their requirements. Utilities: Water: The water service for the residence extends from the water main located under East Cooper Avenue to the southwest of the site. The water service is common trenched with the service for 104 Midland from the water main under the road, curb and gutter, sidewalk, and landscaping. Once the services reach the shared access, they split and the 104 Midland service continues to the east to tie into the neighboring residence. The 108 Midland water service continues up the access and ties into the house near the garage. The service material and sizing are unknown. Sewer: The sewer service extends off the north side of the house. It continues to the northwest and ties into the existing Aspen Consolidated Sanitation District sanitary sewer system via gravity from the residence. Electric and communications: An electric transformer and communications pedestals are located just northwest of the property. Services to the residence extend onto the property and tie into the north side of the structure. Gas: A gas service extends from the right of way by the driveway curb cut and continues up the drive and around the west side of the structure. The gas meter is located on the west side of the garage. All the described conditions can be seen on the Existing Conditions sheet (C.02) of the submitted civil drawings. Stormwater: The residence does not appear to have any existing stormwater management in place. There is a trench drain in the driveway that ties into a drywell by the access entrance. This is shared with a trench drain on the neighboring driveway as well. Upon inspection, appears the trench drains have not been maintained and the existing system is not working as intended. Additionally, sizing of this system is unknown. Hazards: The site is not impacted by any floodplains, mudflows, debris flow areas, avalanche areas, or any known mining activity or deposits. A steep slope separates the Midland Avenue from the residence and the corresponding access drive. The slope varies along hillside, with areas exceeding 1.5:1, or 65 percent. This grade appears to be manmade consisting of fill material when the site was developed, as well as potentially a cut for the construction of Midland Avenue, its curb and gutter and its sidewalk. Given the time period since construction of this slope, a reasonable amount of foliage and native grasses Page 83 of 110 119276 Crystal River Civil LLC 970.510.5312 Page 3 of 5 currently cover the hillside. The hillside is relatively short with no flow lines or points of concentration, and there are no signs of any movement or erosion. The plat for the subdivision references these steep slopes and includes verbiage that no development is to occur within these areas. It does refence the correct area for this hillside, but the platted area does extend into parts of the property that do not pertain to the steep slopes. Proposed Conditions The proposed conditions at 108 Midland Avenue includes the development of a new single-family residence. The proposed structure is relatively in the same location of the existing home, however it will not share any existing foundation or footprint. An attached garage will be located on the southeast corner of the building, and an office space will extend towards the northeast corner. New utility services will be constructed, as well as improvements to the vehicular and emergency access, stormwater infrastructure, and general site plan improvements. Additionally, there are proposed upgrades within the Midland Avenue, including improving and reconstructing the curb and gutter, sidewalk, and retaining wall along the sidewalk along the front of 104 and 108 Midland Avenue. Below are summaries of improvements to each topic. Access: The overall location of the access will remain the same, but major alterations are proposed to bring the access up to code and meet the requirements of Aspen Fire Protection District (AFPD). Discussions with AFPD occurred onsite to ensure he project is meeting all the needs for emergency access. This impacts the neighbor’s driveway as well, which requires regrading of their driveway in order to bring everything into compliance. The access curb cut is proposed in the same location of the existing drive. The curb ramp has been designed to meet the City of Aspen Engineering Standards, in addition to transitions to the existing sidewalk to the south. The drive has been lowered to meet the slope requirements of the city, which impacts the entire length of the 108 Midland driveway and a large portion of the 104 Midland driveway. Turning radii and widths for a fire truck have been analyzed to verify accessibility. The neighbor’s driveway will be regraded to meet the twelve percent slope and will utilize the existing footprint of surfacing. Once the shared driveway splits, the access to 108 Midland extends further west than the existing drive. This allows for planting buffers to remain between the residences, as well as minimizing impacts to the neighboring property. The driveway maintains a 16-foot width and does not exceed twelve percent centerline slope. To achieve this, a series of retaining walls are proposed to minimize impacts on both sides. As the driveway crosses the property line of 108 Midland, the slopes are reduced to six percent, as required for a fire truck turnaround. This turnaround utilizes a large portion of the general vehicle access, but incudes an additional drivable grass paver surface. The driveway continues off the turnaround to the northeast, allowing for additional parking and access to the garage. Page 84 of 110 120277 Crystal River Civil LLC 970.510.5312 Page 4 of 5 Utilities: Water: Given the extensive grading of the site access, improvements will be made to both the neighbors water service and the 108 Midland Avenue service. The services within East Cooper Avenue will be abandoned as per the Aspen Water Department requirements. New services will tap into the water main under Midland Avenue, just west of the shared access curb cut. The neighbor’s service will be replaced and tied into the residence at the existing location. The service for 108 Midland will continue up the driveway and tie into the south side of the building. Sewer: The proposed sanitary sewer service will be similar in location to the existing service, but will be replaced. The service will release from the residence on the north side of the structure and extend downhill to the existing sanitary main. This will be designed to meet all requirements of ACSD. Electric and Communications: The project is currently proposing to utilize the existing transformer and communications pedestals. If any improvements are needed for the existing systems, they will be upgraded as necessary. The services will extend underground and tie into the north side of the structure. Gas: The coverage over the existing services for both 104 and 108 will be compromised due to the access alterations. Services to both residences will be replaced in similar alignments to the existing services. For alterations to the existing utilities, see sheet C.05 for the demolition plan, and proposed utility work is shown on sheet C.06 of the civil drawings. Stormwater: All drainage infrastructure onsite will meet the requirements of the City of Aspen Urban Runoff Management Plan (URMP). CRC met with the engineering department to discuss feasibility, and it is agreed that the current design would be the recommended approach. It was determined that the existing stormwater within Midland Avenue may not have capacity for any site improvements at 108 Midland, so the engineering department encouraged the use of full detention of stormwater onsite. A new drywell is proposed on the neighboring property near the shared portion of the driveway. This drywell utilizes a trench drain to capture the majority of the stormwater off both driveways. A small area below the drywell cannot be collected due to slopes on the site. The drywell has been sized for full detention of a 100-year 1-hour storm event and will have no release of stormwater off the site. Two drywells are proposed on the property to provide full detention of runoff from all impervious improvements. One is located next to the fire truck turnaround to the south of the structure, and the other is proposed to the north. They are both sized for full detention and will not release any stormwater into the right-of-way. All conveyance structures will be sized to meet requirements of the URMP. For permit they will be analyzed to convey a 100-year 1-hour storm event at 80 percent capacity. Page 85 of 110 121278 Crystal River Civil LLC 970.510.5312 Page 5 of 5 Hazards: Given there are no floodplains, mudflows, snow flows, or known mine deposits the development does not impact any of these local hazards. Impacts to the existing slope hazards have been minimized as much as feasibly possible. Although the proposed design does impact the existing steep slopes, they were necessary to improve emergency access to the property. Additionally, all impacted areas are proposed to reduce steep slopes and minimize the manmade anomalies on the site. Several areas being impacted are for reconstruction of the deteriorating retaining walls along the Midland Avenue sidewalk. These impacted areas are represented on sheets C.03 and C.04 of the submitted civil drawings. If there are any comments regarding the design or the analysis performed for the site, feel free to contact me directly. Jay Engstrom Principal, P.E. Crystal River Civil LLC Jay@CrystalRiverCivil.com (970) 404 - 1144 Page 86 of 110 122279 123280 CITY OF ASPEN COMMUNITY DEVELOPMENT DEPARTMENT April 2020 City of Aspen|130 S. Galena St.|(970) 920 5090 Homeowner Association Compliance Policy All land use applications within the City of Aspen are required to include a Homeowner Association Compliance Form (this form) certifying the scope of work included in the land use application complies with all applicable covenants and homeowner association policies. The certification must be signed by the property owner or Attorney representing the property owner. Property Owner (“I”): Name: Email: Phone No.: Address of Property: (subject of application) I certify as follows: (pick one) □This property is not subject to a homeowners association or other form of private covenant. □This property is subject to a homeowners association or private covenant and the improvementsproposed in this land use application do not require approval by the homeowners association orcovenant beneficiary. □This property is subject to a homeowners association or private covenant and the improvementsproposed in this land use application have been approved by the homeowners association or covenant beneficiary. I understand this policy and I understand the City of Aspen does not interpret, enforce, or manage the applicability, meaning or effect of private covenants or homeowner association rules or bylaws. I understand that this document is a public document. Owner signature: date: Owner printed name: or, Attorney signature: date: Attorney printed name: Justin Haynes, Manager; Midland Properties LLC, a Texas limited liability company 108 Midland Avenue! Aspen, CO 81611 Justin Haynes Manager; Midland Properties LLC, a Texas limited liability company 6.13.22 Exhibit I.1 Page 88 of 110 124281 125282 Page 89 of 110 126283 300 SO SPRING ST | 202 | ASPEN, CO 81611 970.925.2855 | BENDONADAMS.COM July 30, 2022 Amy Simon Planning Director City of Aspen 427 Rio Grande Place Aspen, Colorado 81611 RE: 108 Midland Ave.; Aspen, CO Ms. Simon: Please accept this letter authorizing BendonAdams LLC to represent our ownership interests in 108 Midland Avenue and act on our behalf on matters reasonably associated in securing land use approvals for the property. If there are any questions about the foregoing or if I can assist, please do not hesitate to contact me. Property – 108 Midland Ave.; Aspen, CO Legal Description – Lot 1 of the Ferguson Exemption Plat Parcel ID – 2737-181-26-110 Owner – Midland Properties LLC, a Texas limited liability company Kind Regards, Justin Haynes, Manager Midland Properties LLC, a Texas limited liability company 808 N. 5th Street Alpine, TX 79830 Exhibit I.2 Page 90 of 110 127284 PRE-APPLICATION CONFERENCE SUMMARY PLANNER: Garrett Larimer, garrett.larimer@cityofaspen.com REPRESENTATIVE: Sara Adams, sara@bendonadams.com PROJECT LOCATION: 108 Midland Ave., Ferguson Subdivision REQUEST: Minor Amendment to a Planned Development DESCRIPTION: The subject site is zoned R-15a with a PD overlay. The potential applicant has indicated they would like to realign the driveway for Lot 1 (108 Midland Ave.) to be accessed directly from Midland Ave. Lot 1 is currently accessed through an access easement through Lot 4. A plat note on the Ferguson Exemption Plat (Bk. 11 Pg. 59) prohibits development on slopes that exceed 30% without approval from the Board of County Commissioners. The subdivision was approved by the Pitkin County Board of County Commissioners and subsequently annexed into the City of Aspen. The western and northern side of the property, and portions of the adjacent lots, contains slopes in excess of 30%. In order to develop a driveway off Midland Ave. in areas with slopes that exceed 30%, a Minor Amendment to a Planned Development is required to be approved by City Council. The application should clarify whether the application intends to allow for only a driveway within the areas containing slopes over 30%, or if they intend to eliminate restrictions on development in these areas entirely. The review process is the same but will be an important distinction for the review. The application will need to indicate the proposed alignment and dimensions or the driveway, curb cut and other improvements within the areas identified to contains slopes of 30% or greater on the plat. The existing easement across Lot 4 also contains utilities. A plan depicting existing and proposed utility alignments is required as part of the application. A draft plat meeting the Engineering Design Standards will need to be included in the application vacating the existing access and utility easement across Lot 4 and identifying the extents of development within the areas containing slopes exceeding 30% as identified on the plat. If the request is approved by City Council, the amended plat will be recorded with the Pitkin County Clerk and Recorders in addition to the Ordinance passed by City Council. A letter from the HOA approving the proposed realignment is required. A tree removal and proposed landscaping plan is required. Civil drawings indicating compliance with Engineering requirements for the driveway, utilities, and grading is required. The application will need to include written responses to Section 26.445.110.A. Parks and Engineering Departments will be referral agencies on the application. RELEVANT LAND USE CODE SECTIONS: Section Number Section Title 26.304 Common Development Review Procedures 26.445 Planned Developments 26.445.110.D Planned Development – Minor Amendment to the Project Review Approval For your convenience – links to the Land Use Application and Land Use Code are below: Exhibit I.3 Page 91 of 110 128285 Land Use Application Land Use Code Review by: Planning Staff for completeness and recommendation to Council Referrals for recommendation to Planning Staff Council for Decision by Ordinance (Requires 1st and 2nd Reading) Public Hearing: Yes, at City Council Neighborhood Outreach: No Referrals: Engineering - $325 deposit for 1 hr. staff time (Additional/ lesser hours will be billed/ refunded at a rate of $325 per hour.) Parks - $975 Flat fee Planning Fees: $4,550 deposit for 14 hours staff time (Additional/ lesser hours will be billed/ refunded at a rate of $325 per hour.) Total Deposit: $5,850 APPLICATION CHECKLIST: Below is a list of submittal requirements for review. Please email the entire application in a single pdf to garrett.larimer@cityofaspen.com. The fee will be requested after the application is determined to be complete.  Completed Land Use Application and signed Fee Agreement.  Completed Fee Waiver Request Form  Pre-application Conference Summary (this document).  Street address and legal description of the parcel on which development is proposed to occur, consisting of a current (no older than 6 months) certificate from a title insurance company, an ownership and encumbrance report, or attorney licensed to practice in the State of Colorado, listing the names of all owners of the property, and all mortgages, judgments, liens, easements, contracts and agreements affecting the parcel, and demonstrating the owner’s right to apply for the Development Application.  Applicant’s name, address and telephone number in a letter signed by the applicant that states the name, address and telephone number of the representative authorized to act on behalf of the applicant.  HOA Compliance form (Attached).  List of adjacent property owners for both properties within 300’ for public hearing.  An 8 1/2” by 11” vicinity map locating the parcel within the City of Aspen.  Site improvement survey including topography and vegetation showing the current status, certified by a registered land surveyor, licensed in the state of Colorado.  A written description of the proposal (scope of work) and written explanation of how the proposed development complies with the review standards and design guidelines relevant to the application. Page 92 of 110 129286  A statement prepared by a Colorado registered Professional Engineer, and depiction or mapping as necessary, regarding the presence of natural or man-made hazards affecting the property, including flooding, mudflow, debris flow, fault ruptures, landslides, rock or soil creep, rock falls, rock slides, mining activity including mine waste deposit, avalanche or snow slide areas, slopes in excess of thirty percent (30%), and any other natural or man-made hazard or condition that could harm the health, safety, or welfare of the community. Areas with slopes in excess of thirty percent (30%) shall require a slope stability study reviewed by the Colorado Geologic Survey. Also see Chapter 29—Engineering Design Standards regarding identification and mitigation of natural hazards.  A statement prepared by a Colorado registered Professional Engineer, and depiction or mapping as necessary, describing the potential infrastructure upgrades, alignment, design, and mitigation techniques that may be necessary for development of the site to be served by public infrastructure, achieve compliance with Municipal Code Title 29—Engineering Design Standards, and achieve compliance with the City of Aspen Urban Runoff Management Plan (URMP). The information shall be of sufficient detail to determine the acceptable location(s) and extent of development and to understand the necessary upgrades and the possible alignments, designs, or mitigation techniques that may be required.  A written response to each of the review criteria contained in Sections 26.445.050,  A grading and drainage plan showing all grading and how drainage and stormwater is accommodated, and that meets the Conceptual Drainage Plan and Report requirements in the Urban Runoff Management Plan (URMP).  Existing and proposed landscaping plan.  A draft plat meeting Engineering Design Standards. Disclaimer: The foregoing summary is advisory in nature only and is not binding on the City. The summary is based on current zoning, which is subject to change in the future, and upon factual representations that may or may not be accurate. The summary does not create a legal or vested right. Page 93 of 110 130287 CITY OF ASPEN COMMUNITY DEVELOPMENT DEPARTMENT City of Aspen|130 S. Galena St.|(970) 920 5090 April 2020 Agreement to Pay Application Fees Please type or print in all caps Representative Name (if different from Property Owner) Contact info for billing: e-mail: Phone: I understand that the City has adopted, via Ordinance No. 30, Series of 2017, review fees for Land Use applications and payment of these fees is a condition precedent to determining application completeness. I understand that as the property owner that I am responsible for paying all fees for this development application. For flat fees and referral fees: I agree to pay the following fees for the services indicated. I understand that these flat fees are non-refundable. $. flat fee for . $. flat fee for $. flat fee for . $. flat fee for For Deposit cases only: The City and I understand that because of the size, nature or scope of the proposed project, it is not possible at this time to know the full extent or total costs involved in processing the application. I understand that additional costs over and above the deposit may accrue. I understand and agree that it is impracticable for City staff to complete processing, review and presentation of sufficient information to enable legally required findings to be made for project consideration, unless invoices are paid in full. The City and I understand and agree that invoices mailed by the City to the above listed billing address and not returned to the City shall be considered by the City as being received by me. I agree to remit payment within 30 days of presentation of an invoice by the City for such services. I have read, understood, and agree to the Land Use Review Fee Policy including consequences for no-payment. I agree to pay the following initial deposit amounts for the specified hours of staff time. I understand that payment of a deposit does not render and application complete or compliant with approval criteria. If actual recorded costs exceed the initial deposit, I agree to pay additional monthly billings to the City to reimburse the City for the processing of my application at the hourly rates hereinafter stated. $ deposit for hours of Community Development Department staff time. Additional time above the deposit amount will be billed at $325.00 per hour. $ deposit for hours of Engineering Department staff time. Additional time above the deposit amount will be billed at $325.00 per hour. City of Aspen: Phillip Supino, AICP Community Development Director City Use: Fees Due: $ Received $ Case # Signature: PRINT Name: Title: BendonAdams An agreement between the City of Aspen (“City”) and Address of Property: Property Owner Name: 108 Midland Ave.; Aspen, CO 81611 Justin Haynes, Manager Midland Properties LLC, a Texas limited liability company Justin Haynes Manager; Midland Properties LLC, a Texas limited liability company Billing Name and Address - Send Bills to: 808 N. 5th Street; Alpine, TX AP@bigbend.com 432-364-0048 Exhibit I.4 Page 94 of 110 131288 INVOICE Land Title Guarantee Company 5975 Greenwood Plaza Blvd Suite 125 Greenwood Village, CO 80111 970-925-1678 BENDONADAMS LLC ERIN WACKERLE 300 S SPRING STREET SUITE 202 Aspen, CO 81611 Invoice Number:ASP-5037 Date: July 13, 2023 Order Number:62016319 Property Address:104 MIDLAND AVE ASPEN 81611 Invoice Charges Service: TBD Commitment Ref: 62016319 Addr: 104 MIDLAND AVE Party: RICKY C. SANDLER QUALIFIED PERSONAL RESIDENCE TRUST AND MARA SANDLER QUALIFIED PERSONAL RESIDENCE TRUST Total Amount Invoiced: Less Payment(s): Balance Due: $265.00 $265.00 $0.00 $265.00 Due and Payable upon receipt Please make check payable to Land Title Guarantee Company and send to the address at the top of Page 1. Please reference Invoice Number ASP-5037 on your Payment Page 1 invoice.odt 14420 07/2015 07/30/13 11:06:43 AM Reference Your Reference Number:TBD Commitment - 62016319 Our Order Number:ASP-5037 Our Customer Number:79636.2 Invoice Requested by:ERIN WACKERLE Invoice (Process) Date:July 13, 2023 Transaction Invoiced By:Web Services Email Address:system@ltgc.com 132289 Customer Distribution Prevent fraud - Please call a member of our closing team for wire transfer instructions or to initiate a wire transfer. Note that our wiring instructions will never change. Order Number: Q62016319 Date: 07/13/2023 Property Address: 104 MIDLAND AVE ASPEN, CO 81611 For Closing Assistance For Title Assistance Land Title Roaring Fork Valley Title Team 533 E HOPKINS #102 ASPEN, CO 81611 (970) 927-0405 (Work) (970) 925-0610 (Work Fax) valleyresponse@ltgc.com Seller/Owner RICKY C. SANDLER QUALIFIED PERSONAL RESIDENCE TRUST Delivered via: Electronic Mail BENDONADAMS LLC Attention: ERIN WACKERLE 300 S SPRING STREET SUITE 202 Aspen, CO 81611 (406) 531-0806 (Cell) (970) 925-2855 (Work) erin@bendonadams.com Delivered via: Electronic Mail Seller/Owner MARA SANDLER QUALIFIED PERSONAL RESIDENCE TRUST Delivered via: Electronic Mail 133290 Estimate of Title Fees Order Number: Q62016319 Date: 07/13/2023 Property Address: 104 MIDLAND AVE, ASPEN, CO 81611 Seller(s): RICKY C. SANDLER QUALIFIED PERSONAL RESIDENCE TRUST AND MARA SANDLER QUALIFIED PERSONAL RESIDENCE TRUST Buyer(s): Thank you for putting your trust in Land Title. Below is the estimate of title fees for the transaction. The final fees will be collected at closing. Visit ltgc.com to learn more about Land Title. Estimate of Title Insurance Fees "TBD" Commitment $265.00 TOTAL $265.00 Note: The documents linked in this commitment should be reviewed carefully. These documents, such as covenants conditions and restrictions, may affect the title, ownership and use of the property. You may wish to engage legal assistance in order to fully understand and be aware of the implications of the documents on your property. Chain of Title Documents: Pitkin county recorded 12/26/2012 under reception no. 595319 Pitkin county recorded 12/26/2012 under reception no. 595317 Pitkin county recorded 10/17/2006 under reception no. 529945 Pitkin county recorded 10/17/2006 under reception no. 529944 Pitkin county recorded 10/17/2006 under reception no. 529943 Pitkin county recorded 05/04/1994 at book 749 page 569 Pitkin county recorded 09/07/1988 at book 572 page 682 Plat Map(s): Pitkin county recorded 06/01/1981 under reception no. 233197 at book 11 page 59 134291 Copyright 2006-2023 American Land Title Association. All rights reserved. The use of this Form is restricted to ALTA licensees and ALTA members in good standing as of the date of use. All other uses are prohibited. Reprinted under license from the American Land Title Association. Property Address: 104 MIDLAND AVE, ASPEN, CO 81611 1.Effective Date: 06/30/2023 at 5:00 P.M. 2.Policy to be Issued and Proposed Insured: "TBD" Commitment Proposed Insured: $0.00 3.The estate or interest in the land described or referred to in this Commitment and covered herein is: FEE SIMPLE 4.Title to the estate or interest covered herein is at the effective date hereof vested in: RICKY C. SANDLER QUALIFIED PERSONAL RESIDENCE TRUST AND MARA SANDLER QUALIFIED PERSONAL RESIDENCE TRUST 5.The Land referred to in this Commitment is described as follows: LOT A, ACCORDING TO THE FERGUSON SUBDIVISION EXCEPTION AND PUD AMENDMENT PLAT RECORDED APRIL 30, 1986 IN PLAT BOOK 18 AT PAGE 66. ​ COUNTY OF PITKIN​ STATE OF COLORADO ALTA COMMITMENT Old Republic National Title Insurance Company Schedule A Order Number:Q62016319 135292 ALTA COMMITMENT Old Republic National Title Insurance Company Schedule B, Part I (Requirements) Order Number: Q62016319 All of the following Requirements must be met: This proposed Insured must notify the Company in writing of the name of any party not referred to in this Commitment who will obtain an interest in the Land or who will make a loan on the Land. The Company may then make additional Requirements or Exceptions. Pay the agreed amount for the estate or interest to be insured. Pay the premiums, fees, and charges for the Policy to the Company. Documents satisfactory to the Company that convey the Title or create the Mortgage to be insured, or both, must be properly authorized, executed, delivered, and recorded in the Public Records. THIS COMMITMENT IS FOR INFORMATION ONLY, AND NO POLICY WILL BE ISSUED PURSUANT HERETO. 136293 This commitment does not republish any covenants, condition, restriction, or limitation contained in any document referred to in this commitment to the extent that the specific covenant, conditions, restriction, or limitation violates state or federal law based on race, color, religion, sex, sexual orientation, gender identity, handicap, familial status, or national origin. 1.Any facts, rights, interests, or claims thereof, not shown by the Public Records but that could be ascertained by an inspection of the Land or that may be asserted by persons in possession of the Land. 2.Easements, liens or encumbrances, or claims thereof, not shown by the Public Records. 3.Any encroachment, encumbrance, violation, variation, or adverse circumstance affecting the Title that would be disclosed by an accurate and complete land survey of the Land and not shown by the Public Records. 4.Any lien, or right to a lien, for services, labor or material heretofore or hereafter furnished, imposed by law and not shown by the Public Records. 5.Defects, liens, encumbrances, adverse claims or other matters, if any, created, first appearing in the public records or attaching subsequent to the effective date hereof but prior to the date of the proposed insured acquires of record for value the estate or interest or mortgage thereon covered by this Commitment. 6.(a) Taxes or assessments that are not shown as existing liens by the records of any taxing authority that levies taxes or assessments on real property or by the Public Records; (b) proceedings by a public agency that may result in taxes or assessments, or notices of such proceedings, whether or not shown by the records of such agency or by the Public Records. 7.(a) Unpatented mining claims; (b) reservations or exceptions in patents or in Acts authorizing the issuance thereof; (c) water rights, claims or title to water. 8.RIGHT OF PROPRIETOR OF A VEIN OR LODE TO EXTRACT AND REMOVE HIS ORE THEREFROM SHOULD THE SAME BE FOUND TO PENETRATE OR INTERSECT THE PREMISES AS RESERVED IN UNITED STATES PATENT RECORDED JUNE 17, 1949, IN BOOK 175 AT PAGE 246. 9.RIGHT OF WAY FOR DITCHES AS SET FORTH IN INSTRUMENT RECORDED SEPTEMBER 3, 1947 IN BOOK 171 AT PAGE 315. 10.TERMS, CONDITIONS, PROVISIONS AND OBLIGATIONS AS SET FORTH IN RESOLUTION RECORDED SEPTEMBER 14, 1965 IN BOOK 215 AT PAGE 337. 11.TERMS, CONDITIONS, PROVISIONS AND OBLIGATIONS OF AGREEMENT RECORDED AUGUST 13, 1968 IN BOOK 235 AT PAGE 905. 12.TERMS, CONDITIONS, PROVISIONS AND OBLIGATIONS OF RESOLUTION NO. 80-1 OF THE BOARD OF COUNTY COMMISSIONERS OF PITKIN COUNTY, COLORADO RECORDED JANUARY 16, 1980 IN BOOK 382 AT PAGE 162. 13.TERMS, CONDITIONS, PROVISIONS AND OBLIGATIONS OF ORDINANCE NO 16, SERIES OF 1982 RECORDED JUNE 29, 1982 IN BOOK 428 AT PAGE 614 AND ORDINANCE NO. 18, SERIES OF 1982 RECORDED JULY 2, 1982 IN BOOK 428 AT PAGE 751. 14.TERMS, CONDITIONS, PROVISIONS AND OBLIGATIONS AS SET FORTH IN GRANT OF LICENSE RECORDED AUGUST 30, 1982 IN BOOK 431 AT PAGE 820. 15.TERMS, CONDITIONS, PROVISIONS AND OBLIGATIONS AS SET FORTH IN SUBSTITUTION OF EASEMENT RECORDED AUGUST 30, 1982 IN BOOK 431 AT PAGE 824 AND GRANT OF EASEMENT RECORDED AUGUST 30, 1982 IN BOOK 431 AT PAGE 828. ALTA COMMITMENT Old Republic National Title Insurance Company Schedule B, Part II (Exceptions) Order Number: Q62016319 137294 16.EASEMENTS, NOTES, RIGHTS OF WAY AND ALL MATTERS AS SHOWN ON FERGUSON EXEMPTION PLAT RECORDED JUNE 1, 1981 IN PLAT BOOK 11 AT PAGE 59 AND FERGUSON ANNEXATION PLAT RECORDED JUNE 29, 1981 IN PLAT BOOK 13 AT PAGE 65. 17.TERMS, CONDITIONS, PROVISIONS AND OBLIGATIONS OF EASEMENT USE RESTRICTION AGREEMENT RECORDED APRIL 5, 1984 IN BOOK 464 AT PAGE 233. 18.TERMS, CONDITIONS, PROVISIONS AND OBLIGATIONS OF STATEMENT OF EXCEPTION RECORDED APRIL 30, 1986 IN BOOK 509 AT PAGE 876. 19.TERMS, CONDITIONS, PROVISIONS AND OBLIGATIONS OF DECLARATION OF COVENANTS RECORDED APRIL 30, 1986 IN BOOK 509 AT PAGE 878. 20.EASEMENTS, NOTES, RIGHTS OF WAY AND ALL MATTERS AS SHOWN ON FERGUSON SUBDIVISION EXEMPTION PLAT RECORDED APRIL 30, 1986 IN PLAT BOOK 18 AT PAGE 66. 21.TERMS, CONDITIONS, PROVISIONS AND OBLIGATIONS OF STIPULATION RECORDED SEPTEMBER 15, 1995 IN BOOK 793 AT PAGE 709 AND DECREE RECORDED OCTOBER 18, 1995 IN BOOK 797 AT PAGE 149. 22.TERMS, CONDITIONS, PROVISIONS AND OBLIGATIONS AS SET FORTH IN EASEMENT RELOCATION AGREEMENT RECORDED DECEMBER 24, 2008 AS RECEPTION NO. 555278. 23.TERMS, CONDITIONS, PROVISIONS AND OBLIGATIONS AS SET FORTH IN REVOCABLE ENCROACHMENT LICENSE APPLICATION RECORDED JANUARY 5, 2010 AT RECEPTION NO. 565893. ALTA COMMITMENT Old Republic National Title Insurance Company Schedule B, Part II (Exceptions) Order Number: Q62016319 138295 Land Title Guarantee Company Disclosure Statements Note: Pursuant to CRS 10-11-122, notice is hereby given that: Note: Effective September 1, 1997, CRS 30-10-406 requires that all documents received for recording or filing in the clerk and recorder's office shall contain a top margin of at least one inch and a left, right and bottom margin of at least one half of an inch. The clerk and recorder may refuse to record or file any document that does not conform, except that, the requirement for the top margin shall not apply to documents using forms on which space is provided for recording or filing information at the top margin of the document. Note: Colorado Division of Insurance Regulations 8-1-2 requires that "Every title entity shall be responsible for all matters which appear of record prior to the time of recording whenever the title entity conducts the closing and is responsible for recording or filing of legal documents resulting from the transaction which was closed". Provided that Land Title Guarantee Company conducts the closing of the insured transaction and is responsible for recording the legal documents from the transaction, exception number 5 will not appear on the Owner's Title Policy and the Lenders Policy when issued. Note: Affirmative mechanic's lien protection for the Owner may be available (typically by deletion of Exception no. 4 of Schedule B, Section 2 of the Commitment from the Owner's Policy to be issued) upon compliance with the following conditions: No coverage will be given under any circumstances for labor or material for which the insured has contracted for or agreed to pay. Note: Pursuant to CRS 10-11-123, notice is hereby given: The Subject real property may be located in a special taxing district.(A) A certificate of taxes due listing each taxing jurisdiction will be obtained from the county treasurer of the county in which the real property is located or that county treasurer's authorized agent unless the proposed insured provides written instructions to the contrary. (for an Owner's Policy of Title Insurance pertaining to a sale of residential real property). (B) The information regarding special districts and the boundaries of such districts may be obtained from the Board of County Commissioners, the County Clerk and Recorder, or the County Assessor. (C) The land described in Schedule A of this commitment must be a single family residence which includes a condominium or townhouse unit. (A) No labor or materials have been furnished by mechanics or material-men for purposes of construction on the land described in Schedule A of this Commitment within the past 6 months. (B) The Company must receive an appropriate affidavit indemnifying the Company against un-filed mechanic's and material-men's liens. (C) The Company must receive payment of the appropriate premium.(D) If there has been construction, improvements or major repairs undertaken on the property to be purchased within six months prior to the Date of Commitment, the requirements to obtain coverage for unrecorded liens will include: disclosure of certain construction information; financial information as to the seller, the builder and or the contractor; payment of the appropriate premium fully executed Indemnity Agreements satisfactory to the company, and, any additional requirements as may be necessary after an examination of the aforesaid information by the Company. (E) 139296 This notice applies to owner's policy commitments disclosing that a mineral estate has been severed from the surface estate, in Schedule B-2. Note: Pursuant to CRS 10-1-128(6)(a), It is unlawful to knowingly provide false, incomplete, or misleading facts or information to an insurance company for the purpose of defrauding or attempting to defraud the company. Penalties may include imprisonment, fines, denial of insurance, and civil damages. Any insurance company or agent of an insurance company who knowingly provides false, incomplete, or misleading facts or information to a policyholder or claimant for the purpose of defrauding or attempting to defraud the policyholder or claimant with regard to a settlement or award payable from insurance proceeds shall be reported to the Colorado Division of Insurance within the Department of Regulatory Agencies. Note: Pursuant to Colorado Division of Insurance Regulations 8-1-3, notice is hereby given of the availability of a closing protection letter for the lender, purchaser, lessee or seller in connection with this transaction. Note: Pursuant to CRS 24-21-514.5, Colorado notaries may remotely notarize real estate deeds and other documents using real-time audio-video communication technology. You may choose not to use remote notarization for any document. That there is recorded evidence that a mineral estate has been severed, leased, or otherwise conveyed from the surface estate and that there is substantial likelihood that a third party holds some or all interest in oil, gas, other minerals, or geothermal energy in the property; and (A) That such mineral estate may include the right to enter and use the property without the surface owner's permission. (B) 140297 Joint Notice of Privacy Policy of Land Title Guarantee Company Land Title Guarantee Company of Summit County Land Title Insurance Corporation and Old Republic National Title Insurancy Company This Statement is provided to you as a customer of Land Title Guarantee Company as agent for Land Title Insurance Corporation and Old Republic National Title Insurance Company. We want you to know that we recognize and respect your privacy expectations and the requirements of federal and state privacy laws. Information security is one of our highest priorities. We recognize that maintaining your trust and confidence is the bedrock of our business. We maintain and regularly review internal and external safeguards against unauthorized access to your non-public personal information ("Personal Information"). In the course of our business, we may collect Personal Information about you from: applications or other forms we receive from you, including communications sent through TMX, our web-based transaction management system; your transactions with, or from the services being performed by us, our affiliates, or others; a consumer reporting agency, if such information is provided to us in connection with your transaction; and The public records maintained by governmental entities that we obtain either directly from those entities, or from our affiliates and non-affiliates. Our policies regarding the protection of the confidentiality and security of your Personal Information are as follows: We restrict access to all Personal Information about you to those employees who need to know that information in order to provide products and services to you. We may share your Personal Information with affiliated contractors or service providers who provide services in the course of our business, but only to the extent necessary for these providers to perform their services and to provide these services to you as may be required by your transaction. We maintain physical, electronic and procedural safeguards that comply with federal standards to protect your Personal Information from unauthorized access or intrusion. Employees who violate our strict policies and procedures regarding privacy are subject to disciplinary action. We regularly assess security standards and procedures to protect against unauthorized access to Personal Information. WE DO NOT DISCLOSE ANY PERSONAL INFORMATION ABOUT YOU WITH ANYONE FOR ANY PURPOSE THAT IS NOT STATED ABOVE OR PERMITTED BY LAW. Consistent with applicable privacy laws, there are some situations in which Personal Information may be disclosed. We may disclose your Personal Information when you direct or give us permission; when we are required by law to do so, for example, if we are served a subpoena; or when we suspect fraudulent or criminal activities. We also may disclose your Personal Information when otherwise permitted by applicable privacy laws such as, for example, when disclosure is needed to enforce our rights arising out of any agreement, transaction or relationship with you. 141298 Our policy regarding dispute resolution is as follows: Any controversy or claim arising out of or relating to our privacy policy, or the breach thereof, shall be settled by arbitration in accordance with the rules of the American Arbitration Association, and judgment upon the award rendered by the arbitrator(s) may be entered in any court having jurisdiction thereof. 142299 Commitment For Title Insurance Issued by Old Republic National Title Insurance Company NOTICE IMPORTANT—READ CAREFULLY: THIS COMMITMENT IS AN OFFER TO ISSUE ONE OR MORE TITLE INSURANCE POLICIES. ALL CLAIMS OR REMEDIES SOUGHT AGAINST THE COMPANY INVOLVING THE CONTENT OF THIS COMMITMENT OR THE POLICY MUST BE BASED SOLELY IN CONTRACT. THIS COMMITMENT IS NOT AN ABSTRACT OF TITLE, REPORT OF THE CONDITION OF TITLE, LEGAL OPINION, OPINION OF TITLE, OR OTHER REPRESENTATION OF THE STATUS OF TITLE. THE PROCEDURES USED BY THE COMPANY TO DETERMINE INSURABILITY OF THE TITLE, INCLUDING ANY SEARCH AND EXAMINATION, ARE PROPRIETARY TO THE COMPANY, WERE PERFORMED SOLELY FOR THE BENEFIT OF THE COMPANY, AND CREATE NO EXTRACONTRACTUAL LIABILITY TO ANY PERSON, INCLUDING A PROPOSED INSURED. THE COMPANY’S OBLIGATION UNDER THIS COMMITMENT IS TO ISSUE A POLICY TO A PROPOSED INSURED IDENTIFIED IN SCHEDULE A IN ACCORDANCE WITH THE TERMS AND PROVISIONS OF THIS COMMITMENT. THE COMPANY HAS NO LIABILITY OR OBLIGATION INVOLVING THE CONTENT OF THIS COMMITMENT TO ANY OTHER PERSON. . COMMITMENT TO ISSUE POLICY Subject to the Notice; Schedule B, Part I—Requirements; Schedule B, Part II—Exceptions; and the Commitment Conditions, Old Republic National Title Insurance Company, a Minnesota corporation (the “Company”), commits to issue the Policy according to the terms and provisions of this Commitment. This Commitment is effective as of the Commitment Date shown in Schedule A for each Policy described in Schedule A, only when the Company has entered in Schedule A both the specified dollar amount as the Proposed Policy Amount and the name of the Proposed Insured. If all of the Schedule B, Part I—Requirements have not been met within 6 months after the Commitment Date, this Commitment terminates and the Company’s liability and obligation end. COMMITMENT CONDITIONS 1. DEFINITIONS 2. If all of the Schedule B, Part I—Requirements have not been met within the time period specified in the Commitment to Issue Policy, Commitment terminates and the Company’s liability and obligation end. 3. The Company’s liability and obligation is limited by and this Commitment is not valid without: 4. COMPANY’S RIGHT TO AMEND The Company may amend this Commitment at any time. If the Company amends this Commitment to add a defect, lien, encumbrance, adverse claim, or other matter recorded in the Public Records prior to the Commitment Date, any liability of the Company is limited by Commitment Condition 5. The Company shall not be liable for any other amendment to this Commitment. 5. LIMITATIONS OF LIABILITY i. comply with the Schedule B, Part I—Requirements; ii. eliminate, with the Company’s written consent, any Schedule B, Part II—Exceptions; or iii. acquire the Title or create the Mortgage covered by this Commitment. 6. LIABILITY OF THE COMPANY MUST BE BASED ON THIS COMMITMENT “Knowledge” or “Known”: Actual or imputed knowledge, but not constructive notice imparted by the Public Records.(a) “Land”: The land described in Schedule A and affixed improvements that by law constitute real property. The term “Land” does not include any property beyond the lines of the area described in Schedule A, nor any right, title, interest, estate, or easement in abutting streets, roads, avenues, alleys, lanes, ways, or waterways, but this does not modify or limit the extent that a right of access to and from the Land is to be insured by the Policy. (b) “Mortgage”: A mortgage, deed of trust, or other security instrument, including one evidenced by electronic means authorized by law.(c) “Policy”: Each contract of title insurance, in a form adopted by the American Land Title Association, issued or to be issued by the Company pursuant to this Commitment. (d) “Proposed Insured”: Each person identified in Schedule A as the Proposed Insured of each Policy to be issued pursuant to this Commitment.(e) “Proposed Policy Amount”: Each dollar amount specified in Schedule A as the Proposed Policy Amount of each Policy to be issued pursuant to this Commitment. (f) “Public Records”: Records established under state statutes at the Commitment Date for the purpose of imparting constructive notice of matters relating to real property to purchasers for value and without Knowledge. (g) “Title”: The estate or interest described in Schedule A.(h) the Notice;(a) the Commitment to Issue Policy;(b) the Commitment Conditions;(c) Schedule A;(d) Schedule B, Part I—Requirements; and(e) Schedule B, Part II—Exceptions; and(f) a counter-signature by the Company or its issuing agent that may be in electronic form.(g) The Company’s liability under Commitment Condition 4 is limited to the Proposed Insured’s actual expense incurred in the interval between the Company’s delivery to the Proposed Insured of the Commitment and the delivery of the amended Commitment, resulting from the Proposed Insured’s good faith reliance to: (a) The Company shall not be liable under Commitment Condition 5(a) if the Proposed Insured requested the amendment or had Knowledge of the matter and did not notify the Company about it in writing. (b) The Company will only have liability under Commitment Condition 4 if the Proposed Insured would not have incurred the expense had the Commitment included the added matter when the Commitment was first delivered to the Proposed Insured. (c) The Company’s liability shall not exceed the lesser of the Proposed Insured’s actual expense incurred in good faith and described in Commitment Conditions 5(a)(i) through 5(a)(iii) or the Proposed Policy Amount. (d) The Company shall not be liable for the content of the Transaction Identification Data, if any.(e) In no event shall the Company be obligated to issue the Policy referred to in this Commitment unless all of the Schedule B, Part I—Requirements have been met to the satisfaction of the Company. (f) In any event, the Company’s liability is limited by the terms and provisions of the Policy.(g) Only a Proposed Insured identified in Schedule A, and no other person, may make a claim under this Commitment.(a) Any claim must be based in contract and must be restricted solely to the terms and provisions of this Commitment.(b) Until the Policy is issued, this Commitment, as last revised, is the exclusive and entire agreement between the parties with respect to the subject matter of this Commitment and supersedes all prior commitment negotiations, representations, and proposals of any kind, whether written or oral, express or implied, relating to the subject matter of this Commitment. (c) 143300 7. IF THIS COMMITMENT HAS BEEN ISSUED BY AN ISSUING AGENT The issuing agent is the Company’s agent only for the limited purpose of issuing title insurance commitments and policies. The issuing agent is not the Company’s agent for the purpose of providing closing or settlement services. 8. PRO-FORMA POLICY The Company may provide, at the request of a Proposed Insured, a pro-forma policy illustrating the coverage that the Company may provide. A pro-forma policy neither reflects the status of Title at the time that the pro-forma policy is delivered to a Proposed Insured, nor is it a commitment to insure. 9. ARBITRATION The Policy contains an arbitration clause. All arbitrable matters when the Proposed Policy Amount is $2,000,000 or less shall be arbitrated at the option of either the Company or the Proposed Insured as the exclusive remedy of the parties. A Proposed Insured may review a copy of the arbitration rules at http://www.alta.org/arbitration. IN WITNESS WHEREOF, Land Title Insurance Corporation has caused its corporate name and seal to be affixed by its duly authorized officers on the date shown in Schedule A to be valid when countersigned by a validating officer or other authorized signatory. Issued by: Land Title Guarantee Company 3033 East First Avenue Suite 600 Denver, Colorado 80206 303-321-1880 Craig B. Rants, Senior Vice President This page is only a part of a 2016 ALTA® Commitment for Title Insurance issued by Old Republic National Title Insurance Company. This Commitment is not valid without the Notice; the Commitment to Issue Policy; the Commitment Conditions; Schedule A; Schedule B, Part I—Requirements; and Schedule B, Part II —Exceptions; and a counter-signature by the Company or its issuing agent that may be in electronic form. Copyright 2006-2016 American Land Title Association. All rights reserved. The use of this Form (or any derivative thereof) is restricted to ALTA licensees and ALTA members in good standing as of the date of use. All other uses are prohibited. Reprinted under license from the American Land Title Association. The deletion or modification of any Schedule B, Part II—Exception does not constitute an agreement or obligation to provide coverage beyond the terms and provisions of this Commitment or the Policy. (d) Any amendment or endorsement to this Commitment must be in writing and authenticated by a person authorized by the Company.(e) When the Policy is issued, all liability and obligation under this Commitment will end and the Company’s only liability will be under the Policy.(f) 144301 Land Title Guarantee Company Customer Distribution PREVENT FRAUD - Please remember to call a member of our closing team when initiating a wire transfer or providing wiring instructions. Order Number:Q62014472-4 Date: 01/18/2023 Property Address:108 MIDLAND AVE, ASPEN, CO 81611 PLEASE CONTACT YOUR CLOSER OR CLOSER'S ASSISTANT FOR WIRE TRANSFER INSTRUCTIONS For Closing Assistance For Title Assistance Land Title Roaring Fork Valley Title Team 533 E HOPKINS #102 ASPEN, CO 81611 (970) 927-0405 (Work) (970) 925-0610 (Work Fax) valleyresponse@ltgc.com Seller/Owner MIDLAND PROPERTIES LLC Delivered via: Delivered by Realtor COLDWELL BANKER MASON MORSE REAL ESTATE Attention: JUSTIN CLARENCE 514 E HYMAN AVE ASPEN, CO 81611 (970) 688-1804 (Cell) (970) 925-7000 (Work) (970) 925-7027 (Work Fax) judd@aspenluxurybrokers.com Delivered via: Electronic Mail BENDONADAMS Attention: ERIN WACKERLE 300 S SPRING STREET SUITE 202 Aspen, CO 81611 (406) 531-0806 (Cell) (970) 925-2855 (Work) erin@bendonadams.com Delivered via: Electronic Mail Exhibit I.5 Page 95 of 110 145302 Land Title Guarantee Company Estimate of Title Fees Order Number:Q62014472-4 Date: 01/18/2023 Property Address:108 MIDLAND AVE, ASPEN, CO 81611 Parties:A BUYER TO BE DETERMINED MIDLAND PROPERTIES LLC, A TEXAS LIMITED LIABILITY COMPANY Visit Land Title's Website at www.ltgc.com for directions to any of our offices. Estimate of Title insurance Fees "TBD" Commitment $265.00 TBD - TBD Income $-265.00 Total $0.00 If Land Title Guarantee Company will be closing this transaction, the fees listed above will be collected at closing. Thank you for your order! Note: The documents linked in this commitment should be reviewed carefully. These documents, such as covenants conditions and restrictions, may affect the title, ownership and use of the property. You may wish to engage legal assistance in order to fully understand and be aware of the implications of the effect of these documents on your property. Chain of Title Documents: Pitkin county recorded 04/20/2020 under reception no. 664148 Plat Map(s): Pitkin county recorded 06/01/1981 under reception no. 233197 at book 11 page 59 Page 96 of 110 146303 Copyright 2006-2023 American Land Title Association. All rights reserved. The use of this Form is restricted to ALTA licensees and ALTA members in good standing as of the date of use. All other uses are prohibited. Reprinted under license from the American Land Title Association. Property Address: 108 MIDLAND AVE, ASPEN, CO 81611 1.Effective Date: 12/30/2022 at 5:00 P.M. 2.Policy to be Issued and Proposed Insured: "TBD" Commitment Proposed Insured: A BUYER TO BE DETERMINED $0.00 3.The estate or interest in the land described or referred to in this Commitment and covered herein is: A FEE SIMPLE 4.Title to the estate or interest covered herein is at the effective date hereof vested in: MIDLAND PROPERTIES LLC, A TEXAS LIMITED LIABILITY COMPANY 5.The Land referred to in this Commitment is described as follows: LOT 1, ​ FERGUSON EXEMPTION PLAT,​ ACCORDING TO THE PLAT THEREOF RECORDED JUNE 1, 1981 IN PLAT BOOK 11 AT PAGE 59 AS RECEPTION NO. 233197.​ COUNTY OF PITKIN​ STATE OF COLORADO ALTA COMMITMENT Old Republic National Title Insurance Company Schedule A Order Number:Q62014472-4 Page 97 of 110 147304 ALTA COMMITMENT Old Republic National Title Insurance Company Schedule B, Part I (Requirements) Order Number: Q62014472-4 All of the following Requirements must be met: This proposed Insured must notify the Company in writing of the name of any party not referred to in this Commitment who will obtain an interest in the Land or who will make a loan on the Land. The Company may then make additional Requirements or Exceptions. Pay the agreed amount for the estate or interest to be insured. Pay the premiums, fees, and charges for the Policy to the Company. Documents satisfactory to the Company that convey the Title or create the Mortgage to be insured, or both, must be properly authorized, executed, delivered, and recorded in the Public Records. The following will be required should the Company be requested to issue a future commitment to insure: 1.EVIDENCE SATISFACTORY TO THE COMPANY THAT THE TERMS, CONDITIONS AND PROVISIONS OF THE CITY OF ASPEN TRANSFER TAX HAVE BEEN SATISFIED. 2.RELEASE OF DEED OF TRUST DATED APRIL 17, 2020 FROM MIDLAND PROPERTIES LLC, A TEXAS LIMITED LIABILITY COMPANY TO THE PUBLIC TRUSTEE OF PITKIN COUNTY FOR THE USE OF THE NATIONAL BANK OF TEXAS AT FORT WORTH TO SECURE THE SUM OF $4,183,000.00 RECORDED APRIL 20, 2020, UNDER RECEPTION NO. 664151. 3.CERTIFICATE OF GOOD STANDING FROM THE SECRETARY OF STATE OR OTHER APPROPRIATE OFFICER OF THE STATE OF TEXAS, SHOWING THAT MIDLAND PROPERTIES LLC, A TEXAS LIMITED LIABILITY COMPANY IS A DULY ORGANIZED AND EXISTING ENTITY UNDER THE LAWS OF SAID STATE. 4.WRITTEN CONFIRMATION THAT THE INFORMATION CONTAINED IN STATEMENT OF AUTHORITY FOR MIDLAND PROPERTIES LLC, A TEXAS LIMITED LIABILITY COMPANY RECORDED APRIL 20, 2020 UNDER RECEPTION NO. 664152 IS CURRENT. NOTE: SAID INSTRUMENT DISCLOSES JUSTIN HAYNES AS THE MANAGER AUTHORIZED TO EXECUTE INSTRUMENTS CONVEYING, ENCUMBERING OR OTHERWISE AFFECTING TITLE TO REAL PROPERTY ON BEHALF OF SAID ENTITY. IF THIS INFORMATION IS NOT ACCURATE, A CURRENT STATEMENT OF AUTHORITY MUST BE RECORDED. 5.GOOD AND SUFFICIENT DEED FROM MIDLAND PROPERTIES LLC, A TEXAS LIMITED LIABILITY COMPANY TO A BUYER TO BE DETERMINED CONVEYING SUBJECT PROPERTY. NOTE: ADDITIONAL REQUIREMENTS OR EXCEPTIONS MAY BE NECESSARY WHEN THE BUYERS NAMES ARE ADDED TO THIS COMMITMENT. COVERAGES AND/OR CHARGES REFLECTED HEREIN, IF ANY, ARE SUBJECT TO CHANGE UPON RECEIPT OF THE CONTRACT TO BUY AND SELL REAL ESTATE AND ANY AMENDMENTS THERETO. THIS COMMITMENT IS FOR INFORMATION ONLY, AND NO POLICY WILL BE ISSUED PURSUANT HERETO. Page 98 of 110 148305 This commitment does not republish any covenants, condition, restriction, or limitation contained in any document referred to in this commitment to the extent that the specific covenant, conditions, restriction, or limitation violates state or federal law based on race, color, religion, sex, sexual orientation, gender identity, handicap, familial status, or national origin. 1.Any facts, rights, interests, or claims thereof, not shown by the Public Records but that could be ascertained by an inspection of the Land or that may be asserted by persons in possession of the Land. 2.Easements, liens or encumbrances, or claims thereof, not shown by the Public Records. 3.Any encroachment, encumbrance, violation, variation, or adverse circumstance affecting the Title that would be disclosed by an accurate and complete land survey of the Land and not shown by the Public Records. 4.Any lien, or right to a lien, for services, labor or material heretofore or hereafter furnished, imposed by law and not shown by the Public Records. 5.Defects, liens, encumbrances, adverse claims or other matters, if any, created, first appearing in the public records or attaching subsequent to the effective date hereof but prior to the date of the proposed insured acquires of record for value the estate or interest or mortgage thereon covered by this Commitment. 6.(a) Taxes or assessments that are not shown as existing liens by the records of any taxing authority that levies taxes or assessments on real property or by the Public Records; (b) proceedings by a public agency that may result in taxes or assessments, or notices of such proceedings, whether or not shown by the records of such agency or by the Public Records. 7.(a) Unpatented mining claims; (b) reservations or exceptions in patents or in Acts authorizing the issuance thereof; (c) water rights, claims or title to water. 8.RIGHT OF PROPRIETOR OF A VEIN OR LODE TO EXTRACT AND REMOVE HIS ORE THEREFROM SHOULD THE SAME BE FOUND TO PENETRATE OR INTERSECT THE PREMISES AS RESERVED IN UNITED STATES PATENT RECORDED JUNE 17, 1949, IN BOOK 175 AT PAGE 246. 9.RIGHT OF WAY FOR DITCHES AS SET FORTH IN INSTRUMENT RECORDED SEPTEMBER 3, 1947 IN BOOK 171 AT PAGE 315. 10.TERMS, CONDITIONS, PROVISIONS AND OBLIGATIONS OF RESOLUTION NO. 80-1 OF THE BOARD OF COUNTY COMMISSIONERS OF PITKIN COUNTY, COLORADO RECORDED JANUARY 16, 1980 IN BOOK 382 AT PAGE 162. 11.TERMS, CONDITIONS, PROVISIONS AND OBLIGATIONS AS SET FORTH IN RESOLUTION RECORDED SEPTEMBER 14, 1965 IN BOOK 215 AT PAGE 337. 12.TERMS, CONDITIONS, PROVISIONS AND OBLIGATIONS OF ORDINANCE NO 16, SERIES OF 1982 RECORDED JUNE 29, 1982 IN BOOK 428 AT PAGE 614 AND ORDINANCE NO. 18, SERIES OF 1982 RECORDED JULY 2, 1982 IN BOOK 428 AT PAGE 751. 13.TERMS, CONDITIONS, PROVISIONS AND OBLIGATIONS AS SET FORTH IN GRANT OF LICENSE RECORDED AUGUST 30, 1982 IN BOOK 431 AT PAGE 820. ALTA COMMITMENT Old Republic National Title Insurance Company Schedule B, Part II (Exceptions) Order Number: Q62014472-4 Page 99 of 110 149306 14.TERMS, CONDITIONS, PROVISIONS AND OBLIGATIONS AS SET FORTH IN GRANT OF EASEMENT RECORDED AUGUST 30, 1982 IN BOOK 431 AT PAGE 828 AND LETTER AGREEMENT RECORDED SEPTEMBER 1, 1982 IN BOOK 432 AT PAGE 30. 15.EASEMENTS, NOTES, RIGHTS OF WAY AND ALL MATTERS AS SHOWN ON FERGUSON EXEMPTION PLAT RECORDED JUNE 1, 1981 IN PLAT BOOK 11 AT PAGE 59 AND FERGUSON ANNEXATION PLAT RECORDED JUNE 29, 1981 IN PLAT BOOK 13 AT PAGE 65. 16.TERMS, CONDITIONS, PROVISIONS AND OBLIGATIONS OF EASEMENT USE RESTRICTION AGREEMENT RECORDED APRIL 5, 1984 IN BOOK 464 AT PAGE 233. 17.TERMS, CONDITIONS, PROVISIONS AND OBLIGATIONS AS SET FORTH IN EASEMENT RELOCATION AGREEMENT RECORDED DECEMBER 24, 2008 AS RECEPTION NO. 555278. 18.EASEMENTS, NOTES, RIGHTS OF WAY AND ALL MATTERS AS SHOWN ON FERGUSON SUBDIVISION EXEMPTION PLAT RECORDED APRIL 30, 1986 IN PLAT BOOK 18 AT PAGE 66. 19.TERMS, CONDITIONS, PROVISIONS AND OBLIGATIONS AS SET FORTH IN REVOCABLE ENCROACHMENT LICENSE APPLICATION RECORDED JANUARY 5, 2010 AT RECEPTION NO. 565893. 20.TERMS, CONDITIONS AND PROVISIONS OF NOTICE OF APPROVAL RECORDED DECEMBER 07, 2022 UNDER RECEPTION NO. 691900. 21.ANY FACTS, RIGHTS, INTERESTS OR CLAIMS WHICH MAY EXIST OR ARISE BY REASON OF THE FOLLOWING FACTS SHOWN ON IMPROVEMENT SURVEY CERTIFIED FEBRUARY 13, 2015 AND REVISED FEBRUARY 19, 2020 PREPARED BY THE SEXTON SURVEY COMPANY, JOB NO. 15003 OUR ESI 37921609 AND OUR ESI 37921715: ENCROACHMENT OF RETAINING WALLS OUTSIDE PROPERTY LINE UNDERGROUND TELEPHONE LINES UNDERGROUND CABLE TV LINES OVERHEAD UTILITY LINES UNDERGROUND GAS LINES WATER LINES 22.CLAIMS OF RIGHT, TITLE AND/OR INTEREST IN THE PROPERTY BETWEEN THE BOUNDARY LINE AND THE FENCE AS DEPICTED ON THE SURVEY PREPARED BY THE SEXTON SURVEY COMPANY, JOB NO. 15003 WHETHER SAID CLAIMS ARISE BY ABANDONMENT, ADVERSE POSSESSION OR OTHER MEANS. SAID DOCUMENT STORE AS OUR ESI 37921609 ALTA COMMITMENT Old Republic National Title Insurance Company Schedule B, Part II (Exceptions) Order Number: Q62014472-4 Page 100 of 110 150307 LAND TITLE GUARANTEE COMPANY DISCLOSURE STATEMENTS Note: Pursuant to CRS 10-11-122, notice is hereby given that: Note: Effective September 1, 1997, CRS 30-10-406 requires that all documents received for recording or filing in the clerk and recorder's office shall contain a top margin of at least one inch and a left, right and bottom margin of at least one half of an inch. The clerk and recorder may refuse to record or file any document that does not conform, except that, the requirement for the top margin shall not apply to documents using forms on which space is provided for recording or filing information at the top margin of the document. Note: Colorado Division of Insurance Regulations 8-1-2 requires that "Every title entity shall be responsible for all matters which appear of record prior to the time of recording whenever the title entity conducts the closing and is responsible for recording or filing of legal documents resulting from the transaction which was closed". Provided that Land Title Guarantee Company conducts the closing of the insured transaction and is responsible for recording the legal documents from the transaction, exception number 5 will not appear on the Owner's Title Policy and the Lenders Policy when issued. Note: Affirmative mechanic's lien protection for the Owner may be available (typically by deletion of Exception no. 4 of Schedule B, Section 2 of the Commitment from the Owner's Policy to be issued) upon compliance with the following conditions: No coverage will be given under any circumstances for labor or material for which the insured has contracted for or agreed to pay. The Subject real property may be located in a special taxing district.(A) A certificate of taxes due listing each taxing jurisdiction will be obtained from the county treasurer of the county in which the real property is located or that county treasurer's authorized agent unless the proposed insured provides written instructions to the contrary. (for an Owner's Policy of Title Insurance pertaining to a sale of residential real property). (B) The information regarding special districts and the boundaries of such districts may be obtained from the Board of County Commissioners, the County Clerk and Recorder, or the County Assessor. (C) The land described in Schedule A of this commitment must be a single family residence which includes a condominium or townhouse unit. (A) No labor or materials have been furnished by mechanics or material-men for purposes of construction on the land described in Schedule A of this Commitment within the past 6 months. (B) The Company must receive an appropriate affidavit indemnifying the Company against un-filed mechanic's and material-men's liens. (C) The Company must receive payment of the appropriate premium.(D) If there has been construction, improvements or major repairs undertaken on the property to be purchased within six months prior to the Date of Commitment, the requirements to obtain coverage for unrecorded liens will include: disclosure of certain construction information; financial information as to the seller, the builder and or the contractor; payment of the appropriate premium fully executed Indemnity Agreements satisfactory to the company, and, any additional requirements as may be necessary after an examination of the aforesaid information by the Company. (E) Page 101 of 110 151308 Note: Pursuant to CRS 10-11-123, notice is hereby given: This notice applies to owner's policy commitments disclosing that a mineral estate has been severed from the surface estate, in Schedule B-2. Note: Pursuant to CRS 10-1-128(6)(a), It is unlawful to knowingly provide false, incomplete, or misleading facts or information to an insurance company for the purpose of defrauding or attempting to defraud the company. Penalties may include imprisonment, fines, denial of insurance, and civil damages. Any insurance company or agent of an insurance company who knowingly provides false, incomplete, or misleading facts or information to a policyholder or claimant for the purpose of defrauding or attempting to defraud the policyholder or claimant with regard to a settlement or award payable from insurance proceeds shall be reported to the Colorado Division of Insurance within the Department of Regulatory Agencies. Note: Pursuant to Colorado Division of Insurance Regulations 8-1-3, notice is hereby given of the availability of a closing protection letter for the lender, purchaser, lessee or seller in connection with this transaction. Note: Pursuant to CRS 10-1-11(4)(a)(1), Colorado notaries may remotely notarize real estate deeds and other documents using real-time audio-video communication technology. You may choose not to use remote notarization for any document. That there is recorded evidence that a mineral estate has been severed, leased, or otherwise conveyed from the surface estate and that there is substantial likelihood that a third party holds some or all interest in oil, gas, other minerals, or geothermal energy in the property; and (A) That such mineral estate may include the right to enter and use the property without the surface owner's permission. (B) Page 102 of 110 152309 JOINT NOTICE OF PRIVACY POLICY OF LAND TITLE GUARANTEE COMPANY, LAND TITLE GUARANTEE COMPANY OF SUMMIT COUNTY LAND TITLE INSURANCE CORPORATION AND OLD REPUBLIC NATIONAL TITLE INSURANCE COMPANY This Statement is provided to you as a customer of Land Title Guarantee Company as agent for Land Title Insurance Corporation and Old Republic National Title Insurance Company. We want you to know that we recognize and respect your privacy expectations and the requirements of federal and state privacy laws. Information security is one of our highest priorities. We recognize that maintaining your trust and confidence is the bedrock of our business. We maintain and regularly review internal and external safeguards against unauthorized access to your non-public personal information ("Personal Information"). In the course of our business, we may collect Personal Information about you from: applications or other forms we receive from you, including communications sent through TMX, our web-based transaction management system; your transactions with, or from the services being performed by us, our affiliates, or others; a consumer reporting agency, if such information is provided to us in connection with your transaction; and The public records maintained by governmental entities that we obtain either directly from those entities, or from our affiliates and non-affiliates. Our policies regarding the protection of the confidentiality and security of your Personal Information are as follows: We restrict access to all Personal Information about you to those employees who need to know that information in order to provide products and services to you. We may share your Personal Information with affiliated contractors or service providers who provide services in the course of our business, but only to the extent necessary for these providers to perform their services and to provide these services to you as may be required by your transaction. We maintain physical, electronic and procedural safeguards that comply with federal standards to protect your Personal Information from unauthorized access or intrusion. Employees who violate our strict policies and procedures regarding privacy are subject to disciplinary action. We regularly assess security standards and procedures to protect against unauthorized access to Personal Information. WE DO NOT DISCLOSE ANY PERSONAL INFORMATION ABOUT YOU WITH ANYONE FOR ANY PURPOSE THAT IS NOT STATED ABOVE OR PERMITTED BY LAW. Consistent with applicable privacy laws, there are some situations in which Personal Information may be disclosed. We may disclose your Personal Information when you direct or give us permission; when we are required by law to do so, for example, if we are served a subpoena; or when we suspect fraudulent or criminal activities. We also may disclose your Personal Information when otherwise permitted by applicable privacy laws such as, for example, when disclosure is needed to enforce our rights arising out of any agreement, transaction or relationship with you. Our policy regarding dispute resolution is as follows: Any controversy or claim arising out of or relating to our privacy policy, or the breach thereof, shall be settled by arbitration in accordance with the rules of the American Arbitration Association, and judgment upon the award rendered by the arbitrator(s) may be entered in any court having jurisdiction thereof. Page 103 of 110 153310 Commitment For Title Insurance Issued by Old Republic National Title Insurance Company NOTICE IMPORTANT—READ CAREFULLY: THIS COMMITMENT IS AN OFFER TO ISSUE ONE OR MORE TITLE INSURANCE POLICIES. ALL CLAIMS OR REMEDIES SOUGHT AGAINST THE COMPANY INVOLVING THE CONTENT OF THIS COMMITMENT OR THE POLICY MUST BE BASED SOLELY IN CONTRACT. THIS COMMITMENT IS NOT AN ABSTRACT OF TITLE, REPORT OF THE CONDITION OF TITLE, LEGAL OPINION, OPINION OF TITLE, OR OTHER REPRESENTATION OF THE STATUS OF TITLE. THE PROCEDURES USED BY THE COMPANY TO DETERMINE INSURABILITY OF THE TITLE, INCLUDING ANY SEARCH AND EXAMINATION, ARE PROPRIETARY TO THE COMPANY, WERE PERFORMED SOLELY FOR THE BENEFIT OF THE COMPANY, AND CREATE NO EXTRACONTRACTUAL LIABILITY TO ANY PERSON, INCLUDING A PROPOSED INSURED. THE COMPANY’S OBLIGATION UNDER THIS COMMITMENT IS TO ISSUE A POLICY TO A PROPOSED INSURED IDENTIFIED IN SCHEDULE A IN ACCORDANCE WITH THE TERMS AND PROVISIONS OF THIS COMMITMENT. THE COMPANY HAS NO LIABILITY OR OBLIGATION INVOLVING THE CONTENT OF THIS COMMITMENT TO ANY OTHER PERSON. . COMMITMENT TO ISSUE POLICY Subject to the Notice; Schedule B, Part I—Requirements; Schedule B, Part II—Exceptions; and the Commitment Conditions, Old Republic National Title Insurance Company, a Minnesota corporation (the “Company”), commits to issue the Policy according to the terms and provisions of this Commitment. This Commitment is effective as of the Commitment Date shown in Schedule A for each Policy described in Schedule A, only when the Company has entered in Schedule A both the specified dollar amount as the Proposed Policy Amount and the name of the Proposed Insured. If all of the Schedule B, Part I—Requirements have not been met within 6 months after the Commitment Date, this Commitment terminates and the Company’s liability and obligation end. COMMITMENT CONDITIONS 1. DEFINITIONS 2. If all of the Schedule B, Part I—Requirements have not been met within the time period specified in the Commitment to Issue Policy, Commitment terminates and the Company’s liability and obligation end. 3. The Company’s liability and obligation is limited by and this Commitment is not valid without: 4. COMPANY’S RIGHT TO AMEND The Company may amend this Commitment at any time. If the Company amends this Commitment to add a defect, lien, encumbrance, adverse claim, or other matter recorded in the Public Records prior to the Commitment Date, any liability of the Company is limited by Commitment Condition 5. The Company shall not be liable for any other amendment to this Commitment. 5. LIMITATIONS OF LIABILITY i. comply with the Schedule B, Part I—Requirements; ii. eliminate, with the Company’s written consent, any Schedule B, Part II—Exceptions; or iii. acquire the Title or create the Mortgage covered by this Commitment. “Knowledge” or “Known”: Actual or imputed knowledge, but not constructive notice imparted by the Public Records.(a) “Land”: The land described in Schedule A and affixed improvements that by law constitute real property. The term “Land” does not include any property beyond the lines of the area described in Schedule A, nor any right, title, interest, estate, or easement in abutting streets, roads, avenues, alleys, lanes, ways, or waterways, but this does not modify or limit the extent that a right of access to and from the Land is to be insured by the Policy. (b) “Mortgage”: A mortgage, deed of trust, or other security instrument, including one evidenced by electronic means authorized by law.(c) “Policy”: Each contract of title insurance, in a form adopted by the American Land Title Association, issued or to be issued by the Company pursuant to this Commitment. (d) “Proposed Insured”: Each person identified in Schedule A as the Proposed Insured of each Policy to be issued pursuant to this Commitment.(e) “Proposed Policy Amount”: Each dollar amount specified in Schedule A as the Proposed Policy Amount of each Policy to be issued pursuant to this Commitment. (f) “Public Records”: Records established under state statutes at the Commitment Date for the purpose of imparting constructive notice of matters relating to real property to purchasers for value and without Knowledge. (g) “Title”: The estate or interest described in Schedule A.(h) the Notice;(a) the Commitment to Issue Policy;(b) the Commitment Conditions;(c) Schedule A;(d) Schedule B, Part I—Requirements; and(e) Schedule B, Part II—Exceptions; and(f) a counter-signature by the Company or its issuing agent that may be in electronic form.(g) The Company’s liability under Commitment Condition 4 is limited to the Proposed Insured’s actual expense incurred in the interval between the Company’s delivery to the Proposed Insured of the Commitment and the delivery of the amended Commitment, resulting from the Proposed Insured’s good faith reliance to: (a) The Company shall not be liable under Commitment Condition 5(a) if the Proposed Insured requested the amendment or had Knowledge of the matter and did not notify the Company about it in writing. (b) The Company will only have liability under Commitment Condition 4 if the Proposed Insured would not have incurred the expense had the Commitment included the added matter when the Commitment was first delivered to the Proposed Insured. (c) The Company’s liability shall not exceed the lesser of the Proposed Insured’s actual expense incurred in good faith and described in Commitment Conditions 5(a)(i) through 5(a)(iii) or the Proposed Policy Amount. (d) The Company shall not be liable for the content of the Transaction Identification Data, if any.(e) Page 104 of 110 154311 6. LIABILITY OF THE COMPANY MUST BE BASED ON THIS COMMITMENT 7. IF THIS COMMITMENT HAS BEEN ISSUED BY AN ISSUING AGENT The issuing agent is the Company’s agent only for the limited purpose of issuing title insurance commitments and policies. The issuing agent is not the Company’s agent for the purpose of providing closing or settlement services. 8. PRO-FORMA POLICY The Company may provide, at the request of a Proposed Insured, a pro-forma policy illustrating the coverage that the Company may provide. A pro-forma policy neither reflects the status of Title at the time that the pro-forma policy is delivered to a Proposed Insured, nor is it a commitment to insure. 9. ARBITRATION The Policy contains an arbitration clause. All arbitrable matters when the Proposed Policy Amount is $2,000,000 or less shall be arbitrated at the option of either the Company or the Proposed Insured as the exclusive remedy of the parties. A Proposed Insured may review a copy of the arbitration rules at http://www.alta.org/arbitration. IN WITNESS WHEREOF, Land Title Insurance Corporation has caused its corporate name and seal to be affixed by its duly authorized officers on the date shown in Schedule A to be valid when countersigned by a validating officer or other authorized signatory. Issued by: Land Title Guarantee Company 3033 East First Avenue Suite 600 Denver, Colorado 80206 303-321-1880 Craig B. Rants, Senior Vice President This page is only a part of a 2016 ALTA® Commitment for Title Insurance issued by Old Republic National Title Insurance Company. This Commitment is not valid without the Notice; the Commitment to Issue Policy; the Commitment Conditions; Schedule A; Schedule B, Part I—Requirements; and Schedule B, Part II —Exceptions; and a counter-signature by the Company or its issuing agent that may be in electronic form. Copyright 2006-2016 American Land Title Association. All rights reserved. The use of this Form (or any derivative thereof) is restricted to ALTA licensees and ALTA members in good standing as of the date of use. All other uses are prohibited. Reprinted under license from the American Land Title Association. In no event shall the Company be obligated to issue the Policy referred to in this Commitment unless all of the Schedule B, Part I—Requirements have been met to the satisfaction of the Company. (f) In any event, the Company’s liability is limited by the terms and provisions of the Policy.(g) Only a Proposed Insured identified in Schedule A, and no other person, may make a claim under this Commitment.(a) Any claim must be based in contract and must be restricted solely to the terms and provisions of this Commitment.(b) Until the Policy is issued, this Commitment, as last revised, is the exclusive and entire agreement between the parties with respect to the subject matter of this Commitment and supersedes all prior commitment negotiations, representations, and proposals of any kind, whether written or oral, express or implied, relating to the subject matter of this Commitment. (c) The deletion or modification of any Schedule B, Part II—Exception does not constitute an agreement or obligation to provide coverage beyond the terms and provisions of this Commitment or the Policy. (d) Any amendment or endorsement to this Commitment must be in writing and authenticated by a person authorized by the Company.(e) When the Policy is issued, all liability and obligation under this Commitment will end and the Company’s only liability will be under the Policy.(f) Page 105 of 110 155312 Pitkin County Mailing List of 300 Feet Radius Pitkin County GIS presents the information and data on this web site as a service to the public. Every effort has been made to ensure that the information and data contained in this electronic system is accurate, but the accuracy may change. The information maintained by the County may not be complete as to mineral estate ownership and that information should be determined by separate legal and property analysis. Pitkin County GIS makes no warranty or guarantee concerning the completeness, accuracy, or reliability of the content at this site or at other sites to which we link. Assessing accuracy and reliability of information and data is the sole responsibility of the user. The user understands he or she is solely responsible and liable for use, modification, or distribution of any information or data obtained on this web site. This document contains a Mailing List formatted to be printed on Avery 5160 Labels. If printing, DO NOT "fit to page" or "shrink oversized pages." This will manipulate the margins such that they no longer line up on the labels sheet. Print actual size. From Parcel: 273718126110 on 01/30/2023 Instructions: Disclaimer: http://www.pitkinmapsandmore.com Exhibit I.6 Page 106 of 110 156313 111 & 115 PARK AVE TOWNHOME CONDO ASSOC ASPEN, CO 81611 111 PARK AVE 121 ROBINSON ROAD LLC ASPEN, CO 81611 323 W MAIN ST #100 131 MIDLAND LLC SEDALIA, CO 80135 7547 DANIELS PARK RD 139 ROBINSON RD CABIN LLC AUSTIN, TX 78731 3902 WATERS EDGE DR 17A&B LLC SAN FRANCISCO , CA 94123 2625 BAKER ST ADAIR DUPLEX CONDO ASSOC ASPEN, CO 81611 COMMON AREA 126 PARK AVE ALPINE COTTAGES CONDO ASSOC ASPEN, CO 81611 ROBINSON RD ASPEN EDGE CONDO ASSOC ASPEN, CO 81611 1235 E COOPER AVE ASPEN FIN HOME LLC MIAMI, FL 33180 2999 NE 191ST ST #800 ASPEN SCHOOL DISTRICT #1 ASPEN, CO 81611 0235 HIGH SCHOOL RD ASPEN/PITKIN COUNTY HOUSING AUTHORITY ASPEN, CO 81611 18 TRUSCOTT PL BEACH CATHERINE A ASPEN, CO 816112415 311 LACET CT BEIDLEMAN NEAL J & AMY G ASPEN, CO 81612 PO BOX 4362 BENNETT NEIL JAY REV TRUST ASPEN, CO 81611 214 PARK AVE BILCHAK ROSEMARY HOTCHKISS, CO 81419 410 DUKE HILL RD BOLERJACK LISA ASPEN, CO 81611 308 KATHRYNS WAY BROWN DONALD ASPEN, CO 81611-2405 412 KATHRYNS WY BRRRR LLC SAN ANTONIO, TX 78209 120 AUSTIN HWY STE 105 BURKLEY RICHARD & ROBERTA ASPEN, CO 81611-2381 106 ROBINSON DR #F CANTRELL WESLEY R ASPEN, CO 81611-2405 104 KATHRYNS WY CAPSHAW-TAYLOR MICHAEL THOMAS ASPEN, CO 81611 514 KATHRYNS WY #E-11 CASTLE CREEK DEVELOPMENT LLC HOUSTON, TX 77027 4295 SAN FELIPE ST STE 306 CAUDILL ROBERT M & JANICE VOS ASPEN, CO 81611 118 ROBINSON RD CAVE DERYK REV TRUST ASPEN, CO 81611 1195 E COOPER AVE CITY OF ASPEN ASPEN, CO 81611 427 RIO GRANDE PL CLAUSS DUNCAN ASPEN, CO 81611 101 KATHRYNS WY #A-1 CLULEY ELIZABETH ASPEN, CO 816112144 104 LACET CT COOPER DOOPER LLC ALBUQUERQUE, NM 87107 4610 RIO GRANDE LN CORBIN MARCIA A ASPEN, CO 81612 PO BOX 9312 DEELGUEA ALEJANDRO ORTIZ ASPEN, CO 81612 PO BOX 9871 Page 107 of 110 157314 DEJEAN FELIX A III & CAROLYNE OPELOUSAS, LA 70570 1368 KATHERINE DR DEROSE JAMES F & MAUREEN C CHICAGO, IL 60661 333 N DESPLANES ST DOYLE JOHN F & LAURIE FRAMPTON ASPEN, CO 81612 PO BOX 12236 EAST COOPER TOWNHOME HOA ASPEN, CO 81611 LACET CT EE PARK DALE WEST LLC ATLANTA, GA 30328 750 HAMMOND DR BLDG 6 #300 EISENSTAT DAVID H & NINA ASPEN, CO 81611 125 PARK AVE ELLIOTT ELYSE A TRUST ASPEN, CO 81611 610 NORTH ST EMERSON LINDSEY ASPEN, CO 81611 102 LACET CT ERNST TERSIA V ASPEN, CO 81611-2405 206 KATHRYNS WY FAAS MICHAEL & MJ WOLFE ASPEN, CO 816112381 116 ROBINSON RD FAHY ROBIN A & HARVEY V ASPEN, CO 81612 PO BOX 4348 FISCHER BETH A ASPEN, CO 81611 208 LACET CT FORTIER LINDSY S & ADAM J ASPEN, CO 81611 205 LACET CT #205 GLICK DANIEL ASPEN, CO 81612 PO BOX 9910 GROSZ COLLEEN A TRUST CHICAGO, IL 60601 155 N HARBOR DR #3612 HAILEY JOHN T ASPEN, CO 81611 100 ROBINSON RD HAMLIN CONNIE ASPEN, CO 81611 207 LACET CT HAWKEN MADELEINE ASPEN, CO 81612 PO BOX 3695 HENRY LORI ANNE ASPEN, CO 81611 450 S RIVERSIDE AVE #B HENRY PHINEAS P IRREV TRUST ASPEN, CO 81611 450 S RIVERSIDE DR #B ILIC KSENIJA D ASPEN, CO 81612 PO BOX 504 ITTNER ROBERT A JR & ROBERT A SR ASPEN, CO 816128965 PO BOX 8965 JIMENEZ LETITIA M ASPEN, CO 81611 206 LACET CT LAFOUNTAINE ANTOINETTE ASPEN, CO 81611 410 KATHRYNS WY #D1 LAKEVIEW TOWNHOME CONDO ASSOC ASPEN, CO 81611 COMMON AREA MIDLAND AVE LAUGHREN DANA ASPEN, CO 81611 205 KATHRYNS WY #B1 LEAVITT DEREK C LIV TRUST MARINA DEL REY, CA 90292 4712 ADMIRALTY WAY #561 LEAVITT FAMILY TRUST MARINA DEL REY, CA 90292 4712 ADMIRALTY WY #561 LEAVITT GRANT O LIV TRUST MARINA DEL REY, CA 90292 4712 ADMIRALTY WAY #561 LEAVITT LAURA LIV TRUST MARINA DEL REY, CA 90292 4712 ADMIRALTY WAY #561 Page 108 of 110 158315 LEBBY FAMILY TRUST ASPEN, CO 81612 PO BOX 1352 LEE PENNIE ASPEN, CO 81611 450 S RIVERSIDE AVE #A LEVENTHAL ROBERT B ASPEN, CO 81611-2405 515 KATHRYNS WY #E-2 LONGHORN 6603 LLC FORT WORTH, TX 76107 2200 CANTERBURY DR MACALPINE GORDON A ASPEN , CO 81612 PO BOX 5043 MANDRIN VENTURES LLC ASPEN, CO 81611 101 S MILL ST #200 MARGARET MEADOWS LOT 2 CONDO ASSOC ASPEN, CO 81611 COMMON AREA 110 PARK AVE MILLER DAVID W ASPEN, CO 81611 110 ROBINSON RD #D MILLER DAWN & STEPHEN H COCONUT GROVE, FL 33133 3401 N MOORINGS WAY MOLLY GIBSON LOOP CONDO ASSOC ASPEN, CO 81611 COMMON AREA 450 S RIVERSIDE DR NICOLETTI PAUL J III TRUST ASPEN, CO 81611 1180 DALE AVE NOVAK THEODORE J TRUST CHICAGO, IL 60614 618 W DEMING PL OCONNER PHILIP ASPEN, CO 81611 114 ROBINSON RD OKSENHORN CANDICE ASPEN, CO 81611 102 ROBINSON RD OKSENHORN STEWART ASPEN, CO 81611 102 ROBINSON DR OLITSKY STEPHEN L & TAMAR ASPEN, CO 81611 257 PARK AVE P & P ASPEN LLC ASPEN, CO 81611 411 LACET LN PARK DALE TOWNHOMES CONDO ASSOC ASPEN, CO 81611 COMMON AREA 101 DALE AVE PARK/DALE RESIDENCES CONDO ASSOC ASPEN, CO 81611 COMMON AREA 257 PARK AVE POWER MATTHEW ASPEN, CO 81611 207 LACET CT PRICE LINDA J TRUST WOODBRIDGE , NJ 07095 100 WOODBRIDGE CENTER DR REDMOND JOHN D ASPEN, CO 81611 207 KATHRYNS WY RIESSEN MICHAEL ASPEN, CO 81611 313 LACET CT RODBELL PHYLLIS ATLANTA, GA 30327 1101 CREST VALLEY DR RODELL TIMOTHY C & MARJORIE M ASPEN, CO 81612-8005 PO BOX 8005 SACHS SARAH & HARRISON R ASPEN, CO 81611 403 LACET CT SANDLER LIVING TRUST PARADISE VALLEY , AZ 81611 6427 E LUKE AVE SANDLER MARA QPR TRUST NEW YORK, NY 10022 399 PARK AVE #26FL SANDLER RICKY C QPR TRUST NEW YORK, NY 10027 65 E 55TH ST 25TH FL SANDS ALESHA M ASPEN, CO 81611 112 ROBINSON RD #1 Page 109 of 110 159316 SCARLETT ROBIN ASPEN, CO 81611-2405 413 KATHRYNS WY SCHIFF SANFORD M ASPEN, CO 81612 PO BOX 8491 SIKAT 2018 PROPERTY TRUST TORONTO ONTARIO M9P 1R4 CANADA, 3 WESTMOUNT PARK RD SILVA GUSTAVO S ASPEN, CO 81611 112 ROBINSON RD SILVER LAKE FAMILY TRUST ASPEN, CO 81611 128 PARK AVE SMITH JASON ASPEN, CO 81612 PO BOX 3695 SMUGGLER LOOP CONDO ASSOC ASPEN, CO 81611 COMMON AREA 1195 E COOPER AVE SNYDER CONDO ASSOC ASPEN, CO 81611 600 KATHRYNS WAY SUTHREN MARTIN T ASPEN, CO 81611 312 LACET CT TUROK SETH J ASPEN, CO 81611 208 LACET CT UTE EAST RESIDENCES CONDO ASSOC ASPEN, CO 81611 COMMON AREA 1245 E COOPER AVE VOSS ELIZA MAUK & RYANPETER ASPEN, CO 81611 104 ROBINSON RD WELLS RICHARD ASPEN, CO 81612 PO BOX 4867 WHITEASPEN LLC KEY BISCAYNE, FL 33149 30 ISLAND DR WHITEHURST PROPERTIES LLC BALTIMORE, MD 21212 6504 MONTROSE AVE WILSON KIMBERLY ASPEN, CO 81611 102 KATHRYNS WY #A2 WOERNDLE SUB HOA ASPEN, CO 81611 101 S MILL ST #200 WWSP3G LLC ASPEN, CO 81612 PO BOX 4290 YEAGER JAMES W ASPEN, CO 81611 310 LACET CT ZALE MILTON TRUST CHICAGO, IL 60613 3824 N ASHLAND AVE Page 110 of 110 160317 1 MEMORANDUM TO:Mayor and City Council FROM:William Porter, Communications Director Emily Ford, Communications Coordinator THROUGH:Alissa Farrell, Administrative Services Director MEMO DATE:July 17, 2023 MEETING DATE:July 25, 2023 RE:Establishing a Newspaper for Legal Advertising/Notices ____________________________________________________________________________________________________________________________ REQUEST OF COUNCIL:This memorandum seeks your review and approval of the staff recommendation to utilize the Aspen Daily News for the publication of the city's legal notices. Resolution #111, Series 2023 is attached.   SUMMARY AND BACKGROUND: Following Council's directive to conduct a Request for Proposals (RFP) process to identify the most suitable platform for publishing the city's legal notices, an extensive review was undertaken. The Aspen Times and Aspen Daily News were the applicants that responded to the RFP – 2023-199. In this decision-making process, the selection committee utilized a clear set of criteria to guide its assessment. The criteria considered included: Firm Experience, accounting for 30% of the decision-making process. The committee considered circulation within Aspen, publication rates, frequency of publication, and the ability to meet requirements for publication. Team Experience, contributing 25% to the decision-making. The committee assessed team organization and the team's experience. Costs, forming 45% of the decision-making process. The committee evaluated the overall cost effectiveness of each proposal. The committee carried out its mandate in a thorough, systematic manner. It critically evaluated each proposal received in response to the RFP, focusing on the key areas of ability to meet requirements, team experience, and cost. 161 2 DISCUSSION:The Aspen Daily News was determined to be the best fit based on the evaluation framework as the recommended newspaper of record for legal notices/advertising. The selection committee found the Aspen Daily News proposal offered an optimal balance of cost- effectiveness, proven experience, and operational efficiency - the latter being particularly important as the process for the submission of legal advertising has significant less administrative burden on city staff than the current process. Aspen Daily News is the newspaper of record for Pitkin County. The committee also recognizes the additional value of having city legal notices published alongside County legal notices for community accessibility. The purpose of these notices is to keep the public informed about the operations of the government. Consolidating legal advertisements into one location, as offered by the Aspen Daily News, would enhance community communications and offer a more streamlined service to our residents.    FINANCIAL IMPACTS: The financial impact of this transition is considered minimal. The Aspen Daily News offers cost-competitive rates in line with other advertising platforms. Furthermore, the improved efficiency in the publication process is expected to save city staff time, indirectly contributing to cost savings.    ENVIRONMENTAL IMPACTS: There are no significant environmental impacts anticipated with this change.  RECOMMENDATIONS: Based on the above considerations, the committee recommends the approval of the Aspen Daily News as the city's legal notice publication platform. Staff recommends approval of Resolution #111, Series 2023 to formalize this decision.   Approval will signify a valuable step in improving the efficiency of the city’s legal notice publication process, the responsiveness of customer service, and the consolidation of public information, thereby better serving our community.    CITY MANAGER COMMENTS:The city is required by state statute and local land use code to maintain a newspaper of record for legal notices and legal advertisements. Approval of this resolution will ensure the city’s continued compliance with these regulations. It has several years since the city has issued a request for proposals. Moving forward, this service should be rebid at least every five years. – SGO ATTACHMENTS: Resolution 111 of 2023 Professional Services Contract 162 RESOLUTION #111 (Series of 2023) A RESOLUTION OF THE CITY COUNCIL OF THE CITY OF ASPEN, COLORADO, APPROVING A CONTRACT BETWEEN THE CITY OF ASPEN AND THE ASPEN DAILY NEWS AUTHORIZING THE CITY MANAGER TO EXECUTE SAID CONTRACT ON BEHALF OF THE CITY OF ASPEN, COLORADO. WHEREAS, the City of Aspen conducted a process to select a vendor for legal advertising, and; WHEREAS, the City Council acknowledges the need to communicate governmental actions effectively and efficiently to its residents; and, WHEREAS, the process of legal advertisements serves a significant role in maintaining transparency and trust between the City administration and the public; and, WHEREAS, the City Council acknowledges the importance of cost effectiveness and administrative efficiency in choosing the platform for its legal advertisements; and, WHEREAS, the City Council recognizes the value in aligning the placement of City legals with County legals for improved public access and understanding; and, WHEREAS, there has been submitted to the City Council a contract for Legal Advertising between the City of Aspen and the Aspen Daily News, a copy of which is attached as Exhibit A; NOW, THEREFORE, BE IT RESOLVED BY THE CITY COUNCIL OF THE CITY OF ASPEN, COLORADO, That the City Council of the City of Aspen hereby approves that contract for all legal advertisements to be placed with the Aspen Daily News, a copy of which is annexed hereto and incorporated herein, and does hereby authorize the City Manager to execute said agreement on behalf of the City of Aspen. INTRODUCED, READ AND ADOPTED by the City Council of the City of Aspen on the 25th day of July 2023. ___________________________________ Torre, Mayor I, Nicole Henning, duly appointed and acting City Clerk do certify that the foregoing is a true and accurate copy of that resolution adopted by the City Council of the City of Aspen, Colorado, at a meeting held, July 25, 2023. ___________________________________ Nicole Henning, City Clerk 163 Agreement Professional Services Page 0 CITY OF ASPEN STANDARD FORM OF AGREEMENT PROFESSIONAL SERVICES City of Aspen Contract No.: 2023-199 AGREEMENT made this 10th day of July, in the year 2023. BETWEEN the City: Contract Amount: The City of Aspen c/o Sara Ott 427 Rio Grande Place Aspen, Colorado 81611 Phone: (970) 920-5079 And the Professional: The Aspen Daily News c/o David Cook 625 E Main St Suite 204 Aspen, CO 81611 (970) 925-2220 david@aspendailynews.com For the Following Project: 2023-199 City of Aspen Legal Advertising Exhibits appended and made a part of this Agreement: If this Agreement requires the City to pay an amount of money in excess of $50,000.00 it shall not be deemed valid until it has been approved by the City Council of the City of Aspen. City Council Approval: Date: 7/25/2023 Resolution No.: #2023-111 Exhibit A: Scope of Work Exhibit B: Fee Schedule Total: $0.44 per line + $20 liner fee + Column fees Shall not exceed $25,000.00 per year DocuSign Envelope ID: 15880ED9-07DE-46BE-9132-792F5C6B342C 164178 Agreement Professional Services Page 1 The City and Professional agree as set forth below. 1. Scope of Work. Professional shall perform in a competent and professional manner the Scope of Work as set forth at Exhibit A attached hereto and by this reference incorporated herein. 2. Completion. Professional shall commence Work immediately upon receipt of a written Notice to Proceed from the City and complete all phases of the Scope of Work as expeditiously as is consistent with professional skill and care and the orderly progress of the Work in a timely manner through December 31, 2023 (with an option to renew (4) one-year contracts. The parties anticipate that all Work pursuant to this Agreement shall be completed no later than: the deadline for receiving content prior to publication in normal circumstances will be 10am the day before publication, the deadline for receiving content prior to publication in emergency circumstances will be 1pm the day before publication and the deadline for receiving content prior to holidays will be 10am on the last City observed workday prior to holiday. Upon request of the City, Professional shall submit, for the City's approval, a schedule for the performance of Professional's services which shall be adjusted as required as the project proceeds, and which shall include allowances for periods of time required by the City's project engineer for review and approval of submissions and for approvals of authorities having jurisdiction over the project. This schedule, when approved by the City, shall not, except for reasonable cause, be exceeded by the Professional. 3. Payment. In consideration of the work performed, City shall pay Professional on a time and expense basis for all work performed. The hourly rates for work performed by Professional shall not exceed those hourly rates set forth at Exhibit B appended hereto. Except as otherwise mutually agreed to by the parties the payments made to Professional shall not initially exceed the amount set forth above. Professional shall submit, in timely fashion, invoices for work performed. The City shall review such invoices and, if they are considered incorrect or untimely, the City shall review the matter with Professional within ten days from receipt of the Professional's bill. 4. Non-Assignability. Both parties recognize that this Agreement is one for personal services and cannot be transferred, assigned, or sublet by either party without prior written consent of the other. Sub-Contracting, if authorized, shall not relieve the Professional of any of the responsibilities or obligations under this Agreement. Professional shall be and remain solely responsible to the City for the acts, errors, omissions or neglect of any subcontractors’ officers, agents and employees, each of whom shall, for this purpose be deemed to be an agent or employee of the Professional to the extent of the subcontract. The City shall not be obligated to pay or be liable for payment of any sums due which may be due to any sub-contractor. 5. Termination of Procurement. The sale contemplated by this Agreement may be canceled by the City prior to acceptance by the City whenever for any reason and in its sole discretion the City shall determine that such cancellation is in its best interests and convenience. 6. Termination of Professional Services. The Professional or the City may terminate the Professional Services component of this Agreement, without specifying the reason therefor, by giving notice, in writing, addressed to the other party, specifying the effective date of the termination. No fees shall be earned after the effective date of the termination. Upon any termination, all finished or unfinished documents, data, studies, surveys, drawings, maps, models, photographs, reports or other material prepared by the Professional pursuant to this Agreement DocuSign Envelope ID: 15880ED9-07DE-46BE-9132-792F5C6B342C 165179 Agreement Professional Services Page 2 shall become the property of the City. Notwithstanding the above, Professional shall not be relieved of any liability to the City for damages sustained by the City by virtue of any breach of this Agreement by the Professional, and the City may withhold any payments to the Professional for the purposes of set-off until such time as the exact amount of damages due the City from the Professional may be determined. 7. Independent Contractor Status. It is expressly acknowledged and understood by the parties that nothing contained in this agreement shall result in, or be construed as establishing an employment relationship. Professional shall be, and shall perform as, an independent Contractor who agrees to use his or her best efforts to provide the said services on behalf of the City. No agent, employee, or servant of Professional shall be, or shall be deemed to be, the employee, agent or servant of the City. City is interested only in the results obtained under this contract. The manner and means of conducting the work are under the sole control of Professional. None of the benefits provided by City to its employees including, but not limited to, workers' compensation insurance and unemployment insurance, are available from City to the employees, agents or servants of Professional. Professional shall be solely and entirely responsible for its acts and for the acts of Professional's agents, employees, servants and subcontractors during the performance of this contract. Professional shall indemnify City against all liability and loss in connection with, and shall assume full responsibility for payment of all federal, state and local taxes or contributions imposed or required under unemployment insurance, social security and income tax law, with respect to Professional and/or Professional's employees engaged in the performance of the services agreed to herein. 8. Indemnification. Professional agrees to indemnify and hold harmless the City, its officers, employees, insurers, and self-insurance pool, from and against all liability, claims, and demands, on account of injury, loss, or damage, including without limitation claims arising from bodily injury, personal injury, sickness, disease, death, property loss or damage, or any other loss of any kind whatsoever, which arise out of or are in any manner connected with this contract, to the extent and for an amount represented by the degree or percentage such injury, loss, or damage is caused in whole or in part by, or is claimed to be caused in whole or in part by, the wrongful act, omission, error, professional error, mistake, negligence, or other fault of the Professional, any subcontractor of the Professional, or any officer, employee, representative, or agent of the Professional or of any subcontractor of the Professional, or which arises out of any workmen's compensation claim of any employee of the Professional or of any employee of any subcontractor of the Professional. The Professional agrees to investigate, handle, respond to, and to provide defense for and defend against, any such liability, claims or demands at the sole expense of the Professional, or at the option of the City, agrees to pay the City or reimburse the City for the defense costs incurred by the City in connection with, any such liability, claims, or demands. If it is determined by the final judgment of a court of competent jurisdiction that such injury, loss, or damage was caused in whole or in part by the act, omission, or other fault of the City, its officers, or its employees, the City shall reimburse the Professional for the portion of the judgment attributable to such act, omission, or other fault of the City, its officers, or employees. 9. Professional's Insurance. (a) Professional agrees to procure and maintain, at its own expense, a policy or policies of insurance sufficient to insure against all liability, claims, demands, and other obligations DocuSign Envelope ID: 15880ED9-07DE-46BE-9132-792F5C6B342C 166180 Agreement Professional Services Page 3 assumed by the Professional pursuant to Section 8 above. Such insurance shall be in addition to any other insurance requirements imposed by this contract or by law. The Professional shall not be relieved of any liability, claims, demands, or other obligations assumed pursuant to Section 8 above by reason of its failure to procure or maintain insurance, or by reason of its failure to procure or maintain insurance in sufficient amounts, duration, or types. (b) Professional shall procure and maintain, and shall cause any subcontractor of the Professional to procure and maintain, the minimum insurance coverages listed below. Such coverages shall be procured and maintained with forms and insurance acceptable to the City. All coverages shall be continuously maintained to cover all liability, claims, demands, and other obligations assumed by the Professional pursuant to Section 8 above. In the case of any claims-made policy, the necessary retroactive dates and extended reporting periods shall be procured to maintain such continuous coverage. (i) Worker's Compensation insurance to cover obligations imposed by applicable laws for any employee engaged in the performance of work under this contract, and Employers' Liability insurance with minimum limits of ONE MILLION DOLLARS ($1,000,000.00) for each accident, ONE MILLION DOLLARS ($1,000,000.00) disease - policy limit, and ONE MILLION DOLLARS ($1,000,000.00) disease - each employee. Evidence of qualified self-insured status may be substituted for the Worker's Compensation requirements of this paragraph. (ii) Commercial General Liability insurance with minimum combined single limits of TWO MILLION DOLLARS ($2,000,000.00) each occurrence and THREE MILLION DOLLARS ($3,000,000.00) aggregate. The policy shall be applicable to all premises and operations. The policy shall include coverage for bodily injury, broad form property damage (including completed operations), personal injury (including coverage for contractual and employee acts), blanket contractual, independent contractors, products, and completed operations. The policy shall include coverage for explosion, collapse, and underground hazards. The policy shall contain a severability of interests provision. (iii) Comprehensive Automobile Liability insurance with minimum combined single limits for bodily injury and property damage of not less than ONE MILLION DOLLARS ($1,000,000.00) each occurrence and ONE MILLION DOLLARS ($1,000,000.00) aggregate with respect to each Professional's owned, hired and non- owned vehicles assigned to or used in performance of the Scope of Work. The policy shall contain a severability of interests provision. If the Professional has no owned automobiles, the requirements of this Section shall be met by each employee of the Professional providing services to the City under this contract. (iv) Professional Liability insurance with the minimum limits of ONE MILLION DOLLARS ($1,000,000) each claim and TWO MILLION DOLLARS ($2,000,000) aggregate. DocuSign Envelope ID: 15880ED9-07DE-46BE-9132-792F5C6B342C 167181 Agreement Professional Services Page 4 (c) The policy or policies required above shall be endorsed to include the City and the City's officers and employees as additional insureds. Every policy required above shall be primary insurance, and any insurance carried by the City, its officers or employees, or carried by or provided through any insurance pool of the City, shall be excess and not contributory insurance to that provided by Professional. No additional insured endorsement to the policy required above shall contain any exclusion for bodily injury or property damage arising from completed operations. The Professional shall be solely responsible for any deductible losses under any policy required above. (d) The certificate of insurance provided to the City shall be completed by the Professional's insurance agent as evidence that policies providing the required coverages, conditions, and minimum limits are in full force and effect, and shall be reviewed and approved by the City prior to commencement of the contract. No other form of certificate shall be used. The certificate shall identify this contract and shall provide that the coverages afforded under the policies shall not be canceled, terminated or materially changed until at least thirty (30) days prior written notice has been given to the City. (e) Failure on the part of the Professional to procure or maintain policies providing the required coverages, conditions, and minimum limits shall constitute a material breach of contract upon which City may immediately terminate this contract, or at its discretion City may procure or renew any such policy or any extended reporting period thereto and may pay any and all premiums in connection therewith, and all monies so paid by City shall be repaid by Professional to City upon demand, or City may offset the cost of the premiums against monies due to Professional from City. (f) City reserves the right to request and receive a certified copy of any policy and any endorsement thereto. (g) The parties hereto understand and agree that City is relying on, and does not waive or intend to waive by any provision of this contract, the monetary limitations (presently $350,000.00 per person and $990,000 per occurrence) or any other rights, immunities, and protections provided by the Colorado Governmental Immunity Act, Section 24-10-101 et seq., C.R.S., as from time to time amended, or otherwise available to City, its officers, or its employees. 10. City's Insurance. The parties hereto understand that the City is a member of the Colorado Intergovernmental Risk Sharing Agency (CIRSA) and as such participates in the CIRSA Proper- ty/Casualty Pool. Copies of the CIRSA policies and manual are kept at the City of Aspen Risk Management Department and are available to Professional for inspection during normal business hours. City makes no representations whatsoever with respect to specific coverages offered by CIRSA. City shall provide Professional reasonable notice of any changes in its membership or participation in CIRSA. 11. Completeness of Agreement. It is expressly agreed that this agreement contains the entire undertaking of the parties relevant to the subject matter thereof and there are no verbal or written representations, agreements, warranties or promises pertaining to the project matter thereof not expressly incorporated in this writing. DocuSign Envelope ID: 15880ED9-07DE-46BE-9132-792F5C6B342C 168182 Agreement Professional Services Page 5 12. Notice. Any written notices as called for herein may be hand delivered or mailed by certified mail return receipt requested to the respective persons and/or addresses listed above. 13. Non-Discrimination. No discrimination because of race, color, creed, sex, marital status, affectional or sexual orientation, family responsibility, national origin, ancestry, handicap, or religion shall be made in the employment of persons to perform services under this contract. Professional agrees to meet all of the requirements of City's municipal code, Section 15.04.570, pertaining to non-discrimination in employment. 14. Waiver. The waiver by the City of any term, covenant, or condition hereof shall not operate as a waiver of any subsequent breach of the same or any other term. No term, covenant, or condition of this Agreement can be waived except by the written consent of the City, and forbearance or indulgence by the City in any regard whatsoever shall not constitute a waiver of any term, covenant, or condition to be performed by Professional to which the same may apply and, until complete performance by Professional of said term, covenant or condition, the City shall be entitled to invoke any remedy available to it under this Agreement or by law despite any such forbearance or indulgence. 15. Execution of Agreement by City. This Agreement shall be binding upon all parties hereto and their respective heirs, executors, administrators, successors, and assigns. Notwithstanding anything to the contrary contained herein, this Agreement shall not be binding upon the City unless duly executed by the Mayor of the City of Aspen (or a duly authorized official in his absence) following a Motion or Resolution of the Council of the City of Aspen authorizing the Mayor (or a duly authorized official in his absence) to execute the same. 16. Worker Without Authorization prohibited – CRS §8-17.5-101 & §24-76.5-101 Purpose. During the 2021 Colorado legislative session, the legislature passed House Bill 21- 1075 that amended current CRS §8-17.5-102 (1), (2)(a), (2)(b) introductory portion, and (2)(b)(III) as it relates to the employment of and contracting with a “worker without authorization” which is defined as an individual who is unable to provide evidence that the individual is authorized by the federal government to work in the United States. As amended, the current law prohibits all state agencies and political subdivisions, including the Owner, from knowingly hiring a worker without authorization to perform work under a contract, or to knowingly contract with a Professional who knowingly hires with a worker without authorization to perform work under the contract. The law also requires that all contracts for services include certain specific language as set forth in the statutes. The following terms and conditions have been designed to comply with the requirements of this new law. Definitions. The following terms are defined by this reference are incorporated herein and in any contract for services entered into with the Owner. 1. "E-verify program" means the electronic employment verification program created in Public Law 208, 104th Congress, as amended, and expanded in Public Law 156, 108th Congress, as amended, that is jointly administered by the United States Department of Homeland Security and the social security Administration, or its successor program. DocuSign Envelope ID: 15880ED9-07DE-46BE-9132-792F5C6B342C 169183 Agreement Professional Services Page 6 2. "Department program" means the employment verification program established pursuant to Section 8-17.5-102(5)(c). 3. "Public Contract for Services" means this Agreement. 4. "Services" means the furnishing of labor, time, or effort by a Professional or a subprofessional not involving the delivery of a specific end product other than reports that are merely incidental to the required performance. 5. “Worker without authorization” means an individual who is unable to provide evidence that the individual is authorized by the federal government to work in the United States By signing this document, Professional certifies and represents that at this time: 1. Professional shall confirm the employment eligibility of all employees who are newly hired for employment to perform work under the public contract for services; and 2. Professional has participated or attempted to participate in either the e-verify program or the department program in order to verify that new employees are not workers without authorization. Professional hereby confirms that: 1. Professional shall not knowingly employ or contract with a worker without authorization to perform work under the Public Contract for Services. 2. Professional shall not enter into a contract with a subprofessional that fails to certify to the Professional that the subprofessional shall not knowingly employ or contract with a worker without authorization to perform work under the Public Contract for Services. 3. Professional has confirmed the employment eligibility of all employees who are newly hired for employment to perform work under the public contract for services through participation in either the e-verify program or the department program. 4. Professional shall not use the either the e-verify program or the department program procedures to undertake pre-employment screening of job applicants while the Public Contract for Services is being performed. If Professional obtains actual knowledge that a subprofessional performing work under the Public Contract for Services knowingly employs or contracts with a worker without authorization, Professional shall: 1. Notify such subprofessional and the Owner within three days that Professional has actual knowledge that the subprofessional is employing or subcontracting with a worker without authorization: and 2. Terminate the subcontract with the subprofessional if within three days of receiving the notice required pursuant to this section the subprofessional does not stop employing or contracting with the worker without authorization; except that Professional shall not terminate the Public Contract DocuSign Envelope ID: 15880ED9-07DE-46BE-9132-792F5C6B342C 170184 Agreement Professional Services Page 7 for Services with the subprofessional if during such three days the subprofessional provides information to establish that the subprofessional has not knowingly employed or contracted with a worker without authorization. Professional shall comply with any reasonable request by the Colorado Department of Labor and Employment made in the course of an investigation that the Colorado Department of Labor and Employment undertakes or is undertaking pursuant to the authority established in Subsection 8- 17.5-102 (5), C.R.S. If Professional violates any provision of the Public Contract for Services pertaining to the duties imposed by Subsection 8-17.5-102, C.R.S. the Owner may terminate this Agreement. If this Agreement is so terminated, Professional shall be liable for actual damages to the Owner arising out of Professional’s violation of Subsection 8-17.5-102, C.R.S. It is agreed that neither this agreement nor any of its terms, provisions, conditions, representations or covenants can be modified, changed, terminated or amended, waived, superseded or extended except by appropriate written instrument fully executed by the parties. If any of the provisions of this agreement shall be held invalid, illegal or unenforceable it shall not affect or impair the validity, legality or enforceability of any other provision. 17. Warranties Against Contingent Fees, Gratuities, Kickbacks and Conflicts of Interest. (a) Professional warrants that no person or selling agency has been employed or retained to solicit or secure this Contract upon an agreement or understanding for a commission, percentage, brokerage, or contingent fee, excepting bona fide employees or bona fide established commercial or selling agencies maintained by the Professional for the purpose of securing business. (b) Professional agrees not to give any employee of the City a gratuity or any offer of employment in connection with any decision, approval, disapproval, recommendation, preparation of any part of a program requirement or a purchase request, influencing the content of any specification or procurement standard, rendering advice, investigation, auditing, or in any other advisory capacity in any proceeding or application, request for ruling, determination, claim or controversy, or other particular matter, pertaining to this Agreement, or to any solicitation or proposal therefore. (c) Professional represents that no official, officer, employee or representative of the City during the term of this Agreement has or one (1) year thereafter shall have any interest, direct or indirect, in this Agreement or the proceeds thereof, except those that may have been disclosed at the time City Council approved the execution of this Agreement. (d) In addition to other remedies it may have for breach of the prohibitions against contingent fees, gratuities, kickbacks and conflict of interest, the City shall have the right to: 1. Cancel this Purchase Agreement without any liability by the City; DocuSign Envelope ID: 15880ED9-07DE-46BE-9132-792F5C6B342C 171185 Agreement Professional Services Page 8 2. Debar or suspend the offending parties from being a Professional, contractor or subcontractor under City contracts; 3. Deduct from the contract price or consideration, or otherwise recover, the value of anything transferred or received by the Professional; and 4. Recover such value from the offending parties. 18. Fund Availability. Financial obligations of the City payable after the current fiscal year are contingent upon funds for that purpose being appropriated, budgeted and otherwise made available. If this Agreement contemplates the City utilizing state or federal funds to meet its obligations herein, this Agreement shall be contingent upon the availability of those funds for payment pursuant to the terms of this Agreement. 19. General Terms. (a) It is agreed that neither this Agreement nor any of its terms, provisions, conditions, representations or covenants can be modified, changed, terminated or amended, waived, superseded or extended except by appropriate written instrument fully executed by the parties. (b) If any of the provisions of this Agreement shall be held invalid, illegal or unenforceable it shall not affect or impair the validity, legality or enforceability of any other provision. (c) The parties acknowledge and understand that there are no conditions or limitations to this understanding except those as contained herein at the time of the execution hereof and that after execution no alteration, change or modification shall be made except upon a writing signed by the parties. (d) This Agreement shall be governed by the laws of the State of Colorado as from time to time in effect. Venue is agreed to be exclusively in the courts of Pitkin County, Colorado. 20. Electronic Signatures and Electronic Records This Agreement and any amendments hereto may be executed in several counterparts, each of which shall be deemed an original, and all of which together shall constitute one agreement binding on the Parties, notwithstanding the possible event that all Parties may not have signed the same counterpart. Furthermore, each Party consents to the use of electronic signatures by either Party. The Scope of Work, and any other documents requiring a signature hereunder, may be signed electronically in the manner agreed to by the Parties. The Parties agree not to deny the legal effect or enforceability of the Agreement solely because it is in electronic form or because an electronic record was used in its formation. The Parties agree not to object to the admissibility of the Agreement in the form of an electronic record, or a paper copy of an electronic documents, or a paper copy of a document bearing an electronic signature, on the grounds that it is an electronic record or electronic signature or that it is not in its original form or is not an original. 21. Successors and Assigns. This Agreement and all of the covenants hereof shall inure to the benefit of and be binding upon the City and the Professional respectively and their agents, DocuSign Envelope ID: 15880ED9-07DE-46BE-9132-792F5C6B342C 172186 Agreement Professional Services Page 9 representatives, employee, successors, assigns and legal representatives. Neither the City nor the Professional shall have the right to assign, transfer or sublet its interest or obligations hereunder without the written consent of the other party. 22. Third Parties. This Agreement does not and shall not be deemed or construed to confer upon or grant to any third party or parties, except to parties to whom Professional or City may assign this Agreement in accordance with the specific written permission, any right to claim damages or to bring any suit, action or other proceeding against either the City or Professional because of any breach hereof or because of any of the terms, covenants, agreements or conditions herein contained. 23. Attorney’s Fees. In the event that legal action is necessary to enforce any of the provisions of this Agreement, the prevailing party shall be entitled to its costs and reasonable attorney’s fees. 24. Waiver of Presumption. This Agreement was negotiated and reviewed through the mutual efforts of the parties hereto and the parties agree that no construction shall be made or presumption shall arise for or against either party based on any alleged unequal status of the parties in the negotiation, review or drafting of the Agreement. 25. Certification Regarding Debarment, Suspension, Ineligibility, and Voluntary Exclusion. Professional certifies, by acceptance of this Agreement, that neither it nor its principals is presently debarred, suspended, proposed for debarment, declared ineligible or voluntarily excluded from participation in any transaction with a Federal or State department or agency. It further certifies that prior to submitting its Bid that it did include this clause without modification in all lower tier transactions, solicitations, proposals, contracts and subcontracts. In the event that Professional or any lower tier participant was unable to certify to the statement, an explanation was attached to the Bid and was determined by the City to be satisfactory to the City. 26. Integration and Modification. This written Agreement along with all Contract Documents shall constitute the contract between the parties and supersedes or incorporates any prior written and oral agreements of the parties. In addition, Professional understands that no City official or employee, other than the Mayor and City Council acting as a body at a council meeting, has authority to enter into an Agreement or to modify the terms of the Agreement on behalf of the City. Any such Agreement or modification to this Agreement must be in writing and be executed by the parties hereto. 27. Authorized Representative. The undersigned representative of Professional, as an inducement to the City to execute this Agreement, represents that he/she is an authorized representative of Professional for the purposes of executing this Agreement and that he/she has full and complete authority to enter into this Agreement for the terms and conditions specified herein. DocuSign Envelope ID: 15880ED9-07DE-46BE-9132-792F5C6B342C 173187 Agreement Professional Services Page 10 IN WITNESS WHEREOF, the parties hereto have executed, or caused to be executed by their duly authorized officials, this Agreement of which shall be deemed an original on the date first written above. CITY OF ASPEN, COLORADO: PROFESSIONAL: ________________________________ ______________________________ [Signature] [Signature] By: _____________________________ By: _____________________________ [Name] [Name] Title: ____________________________ Title: ____________________________ Date: ___________________ Date: ___________________ Approve as to Form: _____________________ City Attorney DocuSign Envelope ID: 15880ED9-07DE-46BE-9132-792F5C6B342C 7/17/2023 | 7:32:57 PM MDT David Cook Managing Director 174188 Agreement Professional Services Page 11 General Conditions and Special Conditions can be found on City of Aspen Website. Purchasing | Aspen, CO DocuSign Envelope ID: 15880ED9-07DE-46BE-9132-792F5C6B342C 175189 Agreement Professional Services Page 12 EXHIBIT A: SCOPE OF WORK • The Aspen Daily News will publish legal notices for the City of Aspen as defined in the 2023-199 Request for Proposal and will meet requirements for publication as set forth in Colorado Law. • The Aspen Daily News will accept electronic transmission of legal notice or advertisement content from all city offices. • The deadline for receiving content prior to publication in normal circumstances will be 10am the day before publication. • The deadline for receiving content prior to publication in emergency circumstances will be 1pm the day before publication. • The deadline for receiving content prior to holidays will be 10am on the last City observed workday prior to holiday. • The Aspen Daily News will be fully responsible for publishing a corrected legal notice, without charge to the City, in any case where the published notice or advertisement deviates from the original copy submitted by the City. • The Aspen Daily News guarantees it will be responsible for timely and correct billing. • The Aspen Daily News guarantees it will follow all legal requirements for publication established in any law of this state, or by the ordinances, resolutions, or regulations of the City, or by the order of any court of record of this state. Depending on the time of year or current season the Aspen Daily News publishes 8-12,000 print copies daily. During peak season(s) the Aspen Daily News distributes 4,500 copies within the City of Aspen and during the quietest months distribution never drops below 2,500 daily. DocuSign Envelope ID: 15880ED9-07DE-46BE-9132-792F5C6B342C 176190 Agreement Professional Services Page 13 EXHIBIT B: FEE SCHEDULE Publication fees per legal notice: • First run: $0.44 per line; Second run: $0.32 per line • $20 liner fee • Column fees Publication fees per ROP advertisement (government and non-profit rates): • Full page: $645 • ½ page horiz.: $342.50 • ½ page vert.: $342.50 • ½ page: $342/50 • 1/3 page square: $249.43 • 1/3 page vert. $275 • ¼ page horiz. $185 • ¼ page vert. $191.25 • 1/5 page horiz. $117.50 • 1/5 page vert. $123.75 • 1/8 page horiz. $92.50 • 1/8 page vert. $95.63 DocuSign Envelope ID: 15880ED9-07DE-46BE-9132-792F5C6B342C 177191 Agreement Professional Services Page 0 CITY OF ASPEN STANDARD FORM OF AGREEMENT PROFESSIONAL SERVICES City of Aspen Contract No.: 2023-199 AGREEMENT made this 10th day of July, in the year 2023. BETWEEN the City: Contract Amount: The City of Aspen c/o Sara Ott 427 Rio Grande Place Aspen, Colorado 81611 Phone: (970) 920-5079 And the Professional: The Aspen Daily News c/o David Cook 625 E Main St Suite 204 Aspen, CO 81611 (970) 925-2220 david@aspendailynews.com For the Following Project: 2023-199 City of Aspen Legal Advertising Exhibits appended and made a part of this Agreement: If this Agreement requires the City to pay an amount of money in excess of $50,000.00 it shall not be deemed valid until it has been approved by the City Council of the City of Aspen. City Council Approval: Date: 7/25/2023 Resolution No.: #2023-111 Exhibit A: Scope of Work Exhibit B: Fee Schedule Total: $0.44 per line + $20 liner fee + Column fees Shall not exceed $25,000.00 per year DocuSign Envelope ID: 15880ED9-07DE-46BE-9132-792F5C6B342C 164178 Agreement Professional Services Page 1 The City and Professional agree as set forth below. 1. Scope of Work. Professional shall perform in a competent and professional manner the Scope of Work as set forth at Exhibit A attached hereto and by this reference incorporated herein. 2. Completion. Professional shall commence Work immediately upon receipt of a written Notice to Proceed from the City and complete all phases of the Scope of Work as expeditiously as is consistent with professional skill and care and the orderly progress of the Work in a timely manner through December 31, 2023 (with an option to renew (4) one-year contracts. The parties anticipate that all Work pursuant to this Agreement shall be completed no later than: the deadline for receiving content prior to publication in normal circumstances will be 10am the day before publication, the deadline for receiving content prior to publication in emergency circumstances will be 1pm the day before publication and the deadline for receiving content prior to holidays will be 10am on the last City observed workday prior to holiday. Upon request of the City, Professional shall submit, for the City's approval, a schedule for the performance of Professional's services which shall be adjusted as required as the project proceeds, and which shall include allowances for periods of time required by the City's project engineer for review and approval of submissions and for approvals of authorities having jurisdiction over the project. This schedule, when approved by the City, shall not, except for reasonable cause, be exceeded by the Professional. 3. Payment. In consideration of the work performed, City shall pay Professional on a time and expense basis for all work performed. The hourly rates for work performed by Professional shall not exceed those hourly rates set forth at Exhibit B appended hereto. Except as otherwise mutually agreed to by the parties the payments made to Professional shall not initially exceed the amount set forth above. Professional shall submit, in timely fashion, invoices for work performed. The City shall review such invoices and, if they are considered incorrect or untimely, the City shall review the matter with Professional within ten days from receipt of the Professional's bill. 4. Non-Assignability. Both parties recognize that this Agreement is one for personal services and cannot be transferred, assigned, or sublet by either party without prior written consent of the other. Sub-Contracting, if authorized, shall not relieve the Professional of any of the responsibilities or obligations under this Agreement. Professional shall be and remain solely responsible to the City for the acts, errors, omissions or neglect of any subcontractors’ officers, agents and employees, each of whom shall, for this purpose be deemed to be an agent or employee of the Professional to the extent of the subcontract. The City shall not be obligated to pay or be liable for payment of any sums due which may be due to any sub-contractor. 5. Termination of Procurement. The sale contemplated by this Agreement may be canceled by the City prior to acceptance by the City whenever for any reason and in its sole discretion the City shall determine that such cancellation is in its best interests and convenience. 6. Termination of Professional Services. The Professional or the City may terminate the Professional Services component of this Agreement, without specifying the reason therefor, by giving notice, in writing, addressed to the other party, specifying the effective date of the termination. No fees shall be earned after the effective date of the termination. Upon any termination, all finished or unfinished documents, data, studies, surveys, drawings, maps, models, photographs, reports or other material prepared by the Professional pursuant to this Agreement DocuSign Envelope ID: 15880ED9-07DE-46BE-9132-792F5C6B342C 165179 Agreement Professional Services Page 2 shall become the property of the City. Notwithstanding the above, Professional shall not be relieved of any liability to the City for damages sustained by the City by virtue of any breach of this Agreement by the Professional, and the City may withhold any payments to the Professional for the purposes of set-off until such time as the exact amount of damages due the City from the Professional may be determined. 7. Independent Contractor Status. It is expressly acknowledged and understood by the parties that nothing contained in this agreement shall result in, or be construed as establishing an employment relationship. Professional shall be, and shall perform as, an independent Contractor who agrees to use his or her best efforts to provide the said services on behalf of the City. No agent, employee, or servant of Professional shall be, or shall be deemed to be, the employee, agent or servant of the City. City is interested only in the results obtained under this contract. The manner and means of conducting the work are under the sole control of Professional. None of the benefits provided by City to its employees including, but not limited to, workers' compensation insurance and unemployment insurance, are available from City to the employees, agents or servants of Professional. Professional shall be solely and entirely responsible for its acts and for the acts of Professional's agents, employees, servants and subcontractors during the performance of this contract. Professional shall indemnify City against all liability and loss in connection with, and shall assume full responsibility for payment of all federal, state and local taxes or contributions imposed or required under unemployment insurance, social security and income tax law, with respect to Professional and/or Professional's employees engaged in the performance of the services agreed to herein. 8. Indemnification. Professional agrees to indemnify and hold harmless the City, its officers, employees, insurers, and self-insurance pool, from and against all liability, claims, and demands, on account of injury, loss, or damage, including without limitation claims arising from bodily injury, personal injury, sickness, disease, death, property loss or damage, or any other loss of any kind whatsoever, which arise out of or are in any manner connected with this contract, to the extent and for an amount represented by the degree or percentage such injury, loss, or damage is caused in whole or in part by, or is claimed to be caused in whole or in part by, the wrongful act, omission, error, professional error, mistake, negligence, or other fault of the Professional, any subcontractor of the Professional, or any officer, employee, representative, or agent of the Professional or of any subcontractor of the Professional, or which arises out of any workmen's compensation claim of any employee of the Professional or of any employee of any subcontractor of the Professional. The Professional agrees to investigate, handle, respond to, and to provide defense for and defend against, any such liability, claims or demands at the sole expense of the Professional, or at the option of the City, agrees to pay the City or reimburse the City for the defense costs incurred by the City in connection with, any such liability, claims, or demands. If it is determined by the final judgment of a court of competent jurisdiction that such injury, loss, or damage was caused in whole or in part by the act, omission, or other fault of the City, its officers, or its employees, the City shall reimburse the Professional for the portion of the judgment attributable to such act, omission, or other fault of the City, its officers, or employees. 9. Professional's Insurance. (a) Professional agrees to procure and maintain, at its own expense, a policy or policies of insurance sufficient to insure against all liability, claims, demands, and other obligations DocuSign Envelope ID: 15880ED9-07DE-46BE-9132-792F5C6B342C 166180 Agreement Professional Services Page 3 assumed by the Professional pursuant to Section 8 above. Such insurance shall be in addition to any other insurance requirements imposed by this contract or by law. The Professional shall not be relieved of any liability, claims, demands, or other obligations assumed pursuant to Section 8 above by reason of its failure to procure or maintain insurance, or by reason of its failure to procure or maintain insurance in sufficient amounts, duration, or types. (b) Professional shall procure and maintain, and shall cause any subcontractor of the Professional to procure and maintain, the minimum insurance coverages listed below. Such coverages shall be procured and maintained with forms and insurance acceptable to the City. All coverages shall be continuously maintained to cover all liability, claims, demands, and other obligations assumed by the Professional pursuant to Section 8 above. In the case of any claims-made policy, the necessary retroactive dates and extended reporting periods shall be procured to maintain such continuous coverage. (i) Worker's Compensation insurance to cover obligations imposed by applicable laws for any employee engaged in the performance of work under this contract, and Employers' Liability insurance with minimum limits of ONE MILLION DOLLARS ($1,000,000.00) for each accident, ONE MILLION DOLLARS ($1,000,000.00) disease - policy limit, and ONE MILLION DOLLARS ($1,000,000.00) disease - each employee. Evidence of qualified self-insured status may be substituted for the Worker's Compensation requirements of this paragraph. (ii) Commercial General Liability insurance with minimum combined single limits of TWO MILLION DOLLARS ($2,000,000.00) each occurrence and THREE MILLION DOLLARS ($3,000,000.00) aggregate. The policy shall be applicable to all premises and operations. The policy shall include coverage for bodily injury, broad form property damage (including completed operations), personal injury (including coverage for contractual and employee acts), blanket contractual, independent contractors, products, and completed operations. The policy shall include coverage for explosion, collapse, and underground hazards. The policy shall contain a severability of interests provision. (iii) Comprehensive Automobile Liability insurance with minimum combined single limits for bodily injury and property damage of not less than ONE MILLION DOLLARS ($1,000,000.00) each occurrence and ONE MILLION DOLLARS ($1,000,000.00) aggregate with respect to each Professional's owned, hired and non- owned vehicles assigned to or used in performance of the Scope of Work. The policy shall contain a severability of interests provision. If the Professional has no owned automobiles, the requirements of this Section shall be met by each employee of the Professional providing services to the City under this contract. (iv) Professional Liability insurance with the minimum limits of ONE MILLION DOLLARS ($1,000,000) each claim and TWO MILLION DOLLARS ($2,000,000) aggregate. DocuSign Envelope ID: 15880ED9-07DE-46BE-9132-792F5C6B342C 167181 Agreement Professional Services Page 4 (c) The policy or policies required above shall be endorsed to include the City and the City's officers and employees as additional insureds. Every policy required above shall be primary insurance, and any insurance carried by the City, its officers or employees, or carried by or provided through any insurance pool of the City, shall be excess and not contributory insurance to that provided by Professional. No additional insured endorsement to the policy required above shall contain any exclusion for bodily injury or property damage arising from completed operations. The Professional shall be solely responsible for any deductible losses under any policy required above. (d) The certificate of insurance provided to the City shall be completed by the Professional's insurance agent as evidence that policies providing the required coverages, conditions, and minimum limits are in full force and effect, and shall be reviewed and approved by the City prior to commencement of the contract. No other form of certificate shall be used. The certificate shall identify this contract and shall provide that the coverages afforded under the policies shall not be canceled, terminated or materially changed until at least thirty (30) days prior written notice has been given to the City. (e) Failure on the part of the Professional to procure or maintain policies providing the required coverages, conditions, and minimum limits shall constitute a material breach of contract upon which City may immediately terminate this contract, or at its discretion City may procure or renew any such policy or any extended reporting period thereto and may pay any and all premiums in connection therewith, and all monies so paid by City shall be repaid by Professional to City upon demand, or City may offset the cost of the premiums against monies due to Professional from City. (f) City reserves the right to request and receive a certified copy of any policy and any endorsement thereto. (g) The parties hereto understand and agree that City is relying on, and does not waive or intend to waive by any provision of this contract, the monetary limitations (presently $350,000.00 per person and $990,000 per occurrence) or any other rights, immunities, and protections provided by the Colorado Governmental Immunity Act, Section 24-10-101 et seq., C.R.S., as from time to time amended, or otherwise available to City, its officers, or its employees. 10. City's Insurance. The parties hereto understand that the City is a member of the Colorado Intergovernmental Risk Sharing Agency (CIRSA) and as such participates in the CIRSA Proper- ty/Casualty Pool. Copies of the CIRSA policies and manual are kept at the City of Aspen Risk Management Department and are available to Professional for inspection during normal business hours. City makes no representations whatsoever with respect to specific coverages offered by CIRSA. City shall provide Professional reasonable notice of any changes in its membership or participation in CIRSA. 11. Completeness of Agreement. It is expressly agreed that this agreement contains the entire undertaking of the parties relevant to the subject matter thereof and there are no verbal or written representations, agreements, warranties or promises pertaining to the project matter thereof not expressly incorporated in this writing. DocuSign Envelope ID: 15880ED9-07DE-46BE-9132-792F5C6B342C 168182 Agreement Professional Services Page 5 12. Notice. Any written notices as called for herein may be hand delivered or mailed by certified mail return receipt requested to the respective persons and/or addresses listed above. 13. Non-Discrimination. No discrimination because of race, color, creed, sex, marital status, affectional or sexual orientation, family responsibility, national origin, ancestry, handicap, or religion shall be made in the employment of persons to perform services under this contract. Professional agrees to meet all of the requirements of City's municipal code, Section 15.04.570, pertaining to non-discrimination in employment. 14. Waiver. The waiver by the City of any term, covenant, or condition hereof shall not operate as a waiver of any subsequent breach of the same or any other term. No term, covenant, or condition of this Agreement can be waived except by the written consent of the City, and forbearance or indulgence by the City in any regard whatsoever shall not constitute a waiver of any term, covenant, or condition to be performed by Professional to which the same may apply and, until complete performance by Professional of said term, covenant or condition, the City shall be entitled to invoke any remedy available to it under this Agreement or by law despite any such forbearance or indulgence. 15. Execution of Agreement by City. This Agreement shall be binding upon all parties hereto and their respective heirs, executors, administrators, successors, and assigns. Notwithstanding anything to the contrary contained herein, this Agreement shall not be binding upon the City unless duly executed by the Mayor of the City of Aspen (or a duly authorized official in his absence) following a Motion or Resolution of the Council of the City of Aspen authorizing the Mayor (or a duly authorized official in his absence) to execute the same. 16. Worker Without Authorization prohibited – CRS §8-17.5-101 & §24-76.5-101 Purpose. During the 2021 Colorado legislative session, the legislature passed House Bill 21- 1075 that amended current CRS §8-17.5-102 (1), (2)(a), (2)(b) introductory portion, and (2)(b)(III) as it relates to the employment of and contracting with a “worker without authorization” which is defined as an individual who is unable to provide evidence that the individual is authorized by the federal government to work in the United States. As amended, the current law prohibits all state agencies and political subdivisions, including the Owner, from knowingly hiring a worker without authorization to perform work under a contract, or to knowingly contract with a Professional who knowingly hires with a worker without authorization to perform work under the contract. The law also requires that all contracts for services include certain specific language as set forth in the statutes. The following terms and conditions have been designed to comply with the requirements of this new law. Definitions. The following terms are defined by this reference are incorporated herein and in any contract for services entered into with the Owner. 1. "E-verify program" means the electronic employment verification program created in Public Law 208, 104th Congress, as amended, and expanded in Public Law 156, 108th Congress, as amended, that is jointly administered by the United States Department of Homeland Security and the social security Administration, or its successor program. DocuSign Envelope ID: 15880ED9-07DE-46BE-9132-792F5C6B342C 169183 Agreement Professional Services Page 6 2. "Department program" means the employment verification program established pursuant to Section 8-17.5-102(5)(c). 3. "Public Contract for Services" means this Agreement. 4. "Services" means the furnishing of labor, time, or effort by a Professional or a subprofessional not involving the delivery of a specific end product other than reports that are merely incidental to the required performance. 5. “Worker without authorization” means an individual who is unable to provide evidence that the individual is authorized by the federal government to work in the United States By signing this document, Professional certifies and represents that at this time: 1. Professional shall confirm the employment eligibility of all employees who are newly hired for employment to perform work under the public contract for services; and 2. Professional has participated or attempted to participate in either the e-verify program or the department program in order to verify that new employees are not workers without authorization. Professional hereby confirms that: 1. Professional shall not knowingly employ or contract with a worker without authorization to perform work under the Public Contract for Services. 2. Professional shall not enter into a contract with a subprofessional that fails to certify to the Professional that the subprofessional shall not knowingly employ or contract with a worker without authorization to perform work under the Public Contract for Services. 3. Professional has confirmed the employment eligibility of all employees who are newly hired for employment to perform work under the public contract for services through participation in either the e-verify program or the department program. 4. Professional shall not use the either the e-verify program or the department program procedures to undertake pre-employment screening of job applicants while the Public Contract for Services is being performed. If Professional obtains actual knowledge that a subprofessional performing work under the Public Contract for Services knowingly employs or contracts with a worker without authorization, Professional shall: 1. Notify such subprofessional and the Owner within three days that Professional has actual knowledge that the subprofessional is employing or subcontracting with a worker without authorization: and 2. Terminate the subcontract with the subprofessional if within three days of receiving the notice required pursuant to this section the subprofessional does not stop employing or contracting with the worker without authorization; except that Professional shall not terminate the Public Contract DocuSign Envelope ID: 15880ED9-07DE-46BE-9132-792F5C6B342C 170184 Agreement Professional Services Page 7 for Services with the subprofessional if during such three days the subprofessional provides information to establish that the subprofessional has not knowingly employed or contracted with a worker without authorization. Professional shall comply with any reasonable request by the Colorado Department of Labor and Employment made in the course of an investigation that the Colorado Department of Labor and Employment undertakes or is undertaking pursuant to the authority established in Subsection 8- 17.5-102 (5), C.R.S. If Professional violates any provision of the Public Contract for Services pertaining to the duties imposed by Subsection 8-17.5-102, C.R.S. the Owner may terminate this Agreement. If this Agreement is so terminated, Professional shall be liable for actual damages to the Owner arising out of Professional’s violation of Subsection 8-17.5-102, C.R.S. It is agreed that neither this agreement nor any of its terms, provisions, conditions, representations or covenants can be modified, changed, terminated or amended, waived, superseded or extended except by appropriate written instrument fully executed by the parties. If any of the provisions of this agreement shall be held invalid, illegal or unenforceable it shall not affect or impair the validity, legality or enforceability of any other provision. 17. Warranties Against Contingent Fees, Gratuities, Kickbacks and Conflicts of Interest. (a) Professional warrants that no person or selling agency has been employed or retained to solicit or secure this Contract upon an agreement or understanding for a commission, percentage, brokerage, or contingent fee, excepting bona fide employees or bona fide established commercial or selling agencies maintained by the Professional for the purpose of securing business. (b) Professional agrees not to give any employee of the City a gratuity or any offer of employment in connection with any decision, approval, disapproval, recommendation, preparation of any part of a program requirement or a purchase request, influencing the content of any specification or procurement standard, rendering advice, investigation, auditing, or in any other advisory capacity in any proceeding or application, request for ruling, determination, claim or controversy, or other particular matter, pertaining to this Agreement, or to any solicitation or proposal therefore. (c) Professional represents that no official, officer, employee or representative of the City during the term of this Agreement has or one (1) year thereafter shall have any interest, direct or indirect, in this Agreement or the proceeds thereof, except those that may have been disclosed at the time City Council approved the execution of this Agreement. (d) In addition to other remedies it may have for breach of the prohibitions against contingent fees, gratuities, kickbacks and conflict of interest, the City shall have the right to: 1. Cancel this Purchase Agreement without any liability by the City; DocuSign Envelope ID: 15880ED9-07DE-46BE-9132-792F5C6B342C 171185 Agreement Professional Services Page 8 2. Debar or suspend the offending parties from being a Professional, contractor or subcontractor under City contracts; 3. Deduct from the contract price or consideration, or otherwise recover, the value of anything transferred or received by the Professional; and 4. Recover such value from the offending parties. 18. Fund Availability. Financial obligations of the City payable after the current fiscal year are contingent upon funds for that purpose being appropriated, budgeted and otherwise made available. If this Agreement contemplates the City utilizing state or federal funds to meet its obligations herein, this Agreement shall be contingent upon the availability of those funds for payment pursuant to the terms of this Agreement. 19. General Terms. (a) It is agreed that neither this Agreement nor any of its terms, provisions, conditions, representations or covenants can be modified, changed, terminated or amended, waived, superseded or extended except by appropriate written instrument fully executed by the parties. (b) If any of the provisions of this Agreement shall be held invalid, illegal or unenforceable it shall not affect or impair the validity, legality or enforceability of any other provision. (c) The parties acknowledge and understand that there are no conditions or limitations to this understanding except those as contained herein at the time of the execution hereof and that after execution no alteration, change or modification shall be made except upon a writing signed by the parties. (d) This Agreement shall be governed by the laws of the State of Colorado as from time to time in effect. Venue is agreed to be exclusively in the courts of Pitkin County, Colorado. 20. Electronic Signatures and Electronic Records This Agreement and any amendments hereto may be executed in several counterparts, each of which shall be deemed an original, and all of which together shall constitute one agreement binding on the Parties, notwithstanding the possible event that all Parties may not have signed the same counterpart. Furthermore, each Party consents to the use of electronic signatures by either Party. The Scope of Work, and any other documents requiring a signature hereunder, may be signed electronically in the manner agreed to by the Parties. The Parties agree not to deny the legal effect or enforceability of the Agreement solely because it is in electronic form or because an electronic record was used in its formation. The Parties agree not to object to the admissibility of the Agreement in the form of an electronic record, or a paper copy of an electronic documents, or a paper copy of a document bearing an electronic signature, on the grounds that it is an electronic record or electronic signature or that it is not in its original form or is not an original. 21. Successors and Assigns. This Agreement and all of the covenants hereof shall inure to the benefit of and be binding upon the City and the Professional respectively and their agents, DocuSign Envelope ID: 15880ED9-07DE-46BE-9132-792F5C6B342C 172186 Agreement Professional Services Page 9 representatives, employee, successors, assigns and legal representatives. Neither the City nor the Professional shall have the right to assign, transfer or sublet its interest or obligations hereunder without the written consent of the other party. 22. Third Parties. This Agreement does not and shall not be deemed or construed to confer upon or grant to any third party or parties, except to parties to whom Professional or City may assign this Agreement in accordance with the specific written permission, any right to claim damages or to bring any suit, action or other proceeding against either the City or Professional because of any breach hereof or because of any of the terms, covenants, agreements or conditions herein contained. 23. Attorney’s Fees. In the event that legal action is necessary to enforce any of the provisions of this Agreement, the prevailing party shall be entitled to its costs and reasonable attorney’s fees. 24. Waiver of Presumption. This Agreement was negotiated and reviewed through the mutual efforts of the parties hereto and the parties agree that no construction shall be made or presumption shall arise for or against either party based on any alleged unequal status of the parties in the negotiation, review or drafting of the Agreement. 25. Certification Regarding Debarment, Suspension, Ineligibility, and Voluntary Exclusion. Professional certifies, by acceptance of this Agreement, that neither it nor its principals is presently debarred, suspended, proposed for debarment, declared ineligible or voluntarily excluded from participation in any transaction with a Federal or State department or agency. It further certifies that prior to submitting its Bid that it did include this clause without modification in all lower tier transactions, solicitations, proposals, contracts and subcontracts. In the event that Professional or any lower tier participant was unable to certify to the statement, an explanation was attached to the Bid and was determined by the City to be satisfactory to the City. 26. Integration and Modification. This written Agreement along with all Contract Documents shall constitute the contract between the parties and supersedes or incorporates any prior written and oral agreements of the parties. In addition, Professional understands that no City official or employee, other than the Mayor and City Council acting as a body at a council meeting, has authority to enter into an Agreement or to modify the terms of the Agreement on behalf of the City. Any such Agreement or modification to this Agreement must be in writing and be executed by the parties hereto. 27. Authorized Representative. The undersigned representative of Professional, as an inducement to the City to execute this Agreement, represents that he/she is an authorized representative of Professional for the purposes of executing this Agreement and that he/she has full and complete authority to enter into this Agreement for the terms and conditions specified herein. DocuSign Envelope ID: 15880ED9-07DE-46BE-9132-792F5C6B342C 173187 Agreement Professional Services Page 10 IN WITNESS WHEREOF, the parties hereto have executed, or caused to be executed by their duly authorized officials, this Agreement of which shall be deemed an original on the date first written above. CITY OF ASPEN, COLORADO: PROFESSIONAL: ________________________________ ______________________________ [Signature] [Signature] By: _____________________________ By: _____________________________ [Name] [Name] Title: ____________________________ Title: ____________________________ Date: ___________________ Date: ___________________ Approve as to Form: _____________________ City Attorney DocuSign Envelope ID: 15880ED9-07DE-46BE-9132-792F5C6B342C 7/17/2023 | 7:32:57 PM MDT David Cook Managing Director 174188 Agreement Professional Services Page 11 General Conditions and Special Conditions can be found on City of Aspen Website. Purchasing | Aspen, CO DocuSign Envelope ID: 15880ED9-07DE-46BE-9132-792F5C6B342C 175189 Agreement Professional Services Page 12 EXHIBIT A: SCOPE OF WORK • The Aspen Daily News will publish legal notices for the City of Aspen as defined in the 2023-199 Request for Proposal and will meet requirements for publication as set forth in Colorado Law. • The Aspen Daily News will accept electronic transmission of legal notice or advertisement content from all city offices. • The deadline for receiving content prior to publication in normal circumstances will be 10am the day before publication. • The deadline for receiving content prior to publication in emergency circumstances will be 1pm the day before publication. • The deadline for receiving content prior to holidays will be 10am on the last City observed workday prior to holiday. • The Aspen Daily News will be fully responsible for publishing a corrected legal notice, without charge to the City, in any case where the published notice or advertisement deviates from the original copy submitted by the City. • The Aspen Daily News guarantees it will be responsible for timely and correct billing. • The Aspen Daily News guarantees it will follow all legal requirements for publication established in any law of this state, or by the ordinances, resolutions, or regulations of the City, or by the order of any court of record of this state. Depending on the time of year or current season the Aspen Daily News publishes 8-12,000 print copies daily. During peak season(s) the Aspen Daily News distributes 4,500 copies within the City of Aspen and during the quietest months distribution never drops below 2,500 daily. DocuSign Envelope ID: 15880ED9-07DE-46BE-9132-792F5C6B342C 176190 Agreement Professional Services Page 13 EXHIBIT B: FEE SCHEDULE Publication fees per legal notice: • First run: $0.44 per line; Second run: $0.32 per line • $20 liner fee • Column fees Publication fees per ROP advertisement (government and non-profit rates): • Full page: $645 • ½ page horiz.: $342.50 • ½ page vert.: $342.50 • ½ page: $342/50 • 1/3 page square: $249.43 • 1/3 page vert. $275 • ¼ page horiz. $185 • ¼ page vert. $191.25 • 1/5 page horiz. $117.50 • 1/5 page vert. $123.75 • 1/8 page horiz. $92.50 • 1/8 page vert. $95.63 DocuSign Envelope ID: 15880ED9-07DE-46BE-9132-792F5C6B342C 177191 108 Midland Avenue Ferguson Subdivision Lot 1 PD Amendment January 30, 2023 35192 TABLE OF CONTENTS 04 10 14 64 Project summary and background A. Review Criteria B. Land Use Application Form F. Improvement survey including slope analysis dated August 2022 66 66 71 82 G. Civil engineering G.1 Intent to serve letters G.2 Civil drawings including grading and drainage G.3 Statements from civil engineer 16 16 23 D. Architecture D.1 Existing conditions D2 Proposed design set 48 50 D.3 Residential Design Standards D.4 Landscape Plan - existing and proposed 55 D.5 Renderings 60 61 61 D.6 Neighborhood context E. Past approvals E.1 2022 Demolition allotment development order 62 63 E.2 1981 Ferguson subdivision plat E.3 1982 Ferguson annexation plat 15 C. Vicinity map 87 H. Draft plat 36193 TABLE OF CONTENTS 88 I. Required land use forms 88 90 I.1. HOA Form and Neighbor Consent I.2 Authorization to represent 91 94 I.3 Pre-application summary I.4 Agreement to pay 95 I.5 Proof of ownership 106 I.6 Mailing list for adjacent properties within 300’ dated January 2023 37194 300 SO SPRING ST | 202 | ASPEN, CO 81611 970.925.2855 | BENDONADAMS.COM January 30, 2023 Aspen City Council c/o Garrett Larimer, Senior Planner Community Development Department Re: 108 Midland Avenue PD amendment Dear City Council and planning staff, Please accept this application to amend the Ferguson Exemption Subdivision Plat for Lot 1 - 108 Midland Avenue. 108 Midland is located along Midland and Cooper Avenues with access from Cooper Avenue via an access easement across Lot 4. Snyder Park abuts the north end of 108 Midland Avenue. The property is developed with a single family home and has received a 2022 demolition allotment to demolish the existing home and to construct a new single family home. This application requests approval to develop within a section of land designated on the original Figure 1: Ferguson Subdivision highlighted in blue. Star indicates subject property, 108 Midland Avenue. Page 4 of 110 38195 Ferguson Exemption Subdivision Plat as requiring specific approval for development activity. Background The Ferguson Subdivision Exemption was approved in 1981 by the Pitkin County Board of County Commissioners (BOCC). The 1981 subdivision exemption plat includes the following plat note “development of slope over 30% is prohibited as specifically delineated on the plat without approval from the Board of County Commissioners.” At the time, 108 Midland Avenue was almost all sloped terrain and the Pitkin County Code prohibited any development on slopes greater than 30%1. It can be assumed that the BOCC did not want (and was not legally allowed) to create a parcel that was undevelopable; and therefore placed a condition that enabled development within the 30% slope area upon additional review by the Board rather than just outright prohibit any development on the parcel. The County’s Code has since been amended to remove this absolute prohibition. Figure 2: 1980 Aspen GIS aerial map. Orange dotted line show general location of 108 Midland Avenue. 1 Pitkin County Land Use Code dated 1979, Section 5-401.2.h.1. Page 5 of 110 39196 In 1982 the Ferguson Subdivision neighborhood was annexed into the City of Aspen (Ordinance 16-1982) and zoned R15A-PUD (Ordinance 18-1982), which remains in place today. The “PUD” designation was common for developments approved in the County and then annexed into the City – as this legalized any existing non-conformities resultant from applying city zoning. The 1981 requirement for special BoCC approval in the sloped areas was never addressed during the annexation process and is not included on the annexation plat. The requirement remains on the original subdivision plat. A single family home is exempt from a planned development review per Section 26.445.020 Planned Development - Applicability, “in the absence of an approved site specific development plan, a single detached, two detached, or a duplex residential dwelling, if listed as a permitted use in the property’s zoning, may be developed in conformance with the provisions of the Zone District.” This property requests approval for development according to the 1981 plat note and in conformance with the provisions of the Zone District. Platted Slope verses Actual Slope The actual slopes on the property do not correlate to the “30% slope” area on the 1981 plat – the platted slopes. An analysis of the property shows that the actual 30% slopes (shown in blue) do not align with the 1981 platted slopes specifically in the area to the north of the existing house when comparing Figure 3 and Figure 4. Figure 3: 1981 Ferguson Exemption Plat. Blue area highlights the area indicates the platted 30% slope. Figure 4: 108 Midland Avenue 2022 survey with slopes. Blue highlight shows actual 30% slopes Page 6 of 110 40197 Request We respectfully request the ability to develop in the specified 30% sloped areas for the driveway, a small portion of the proposed new house, and the conversion of an existing curb cut into a walking pathway on Midland Avenue. Driveway realignment The existing driveway does not meet current Engineering Design Standards or Fire Code requirements regarding slopes, width, access right of way ramps, or turnaround space. In addition, the existing location of the driveway does not align with the driveway location on the 1981 plat. The proposed driveway cures the existing non-conformities and meets current City of Aspen Code requirements. The driveway is proposed within the platted 30% slope area; however, this is necessary to meet Engineering and Fire Codes. Renderings in Exhibit D demonstrate very minimal visual impact, if any, of the driveway realignment on the Midland Avenue pedestrian and vehicular experience. The diagram below shows the areas within the platted 30% slope impacted by the driveway realignment. A total of 795 sf of the platted 30% sloped area is proposed to be impacted. Figure 5 shows the impact on the platted slope and Figure 6 shows the impact on the actual slope. Figure 5: Detail of the proposed realigned driveway. Blue and orange highlights show areas within the platted 30% sloped area per the 1981 Ferguson subdivision plat. Figure 5: Detail of proposed realigned driveway with impacts on actual 30% slopes per the August 2022 survey shown in blue and orange. Page 7 of 110 41198 Single family home location The property owner received a demolition allotment to demolish and replace the aging and very energy inefficient single family home with a new house that meets the City’s energy and climate goals, and complies with R-15A zoning. The location of the proposed new home is similar to existing but pushed to the north slightly. A comparison of the proposed home location within the 1981 platted 30% slope (Exhibit 7) versus the actual slope condition (Exhibit 8) illustrates the minimal impact on actual slopes. A total of 461 sf of development is located within actual 30% sloped areas, and a total of 2,734 sf of development is located within the 1981 platted sloped area. Figure 7: Detail of the proposed home footprint. Orange highlights show areas within the platted 30% sloped area per the 1981 Ferguson subdivision plat. Figure 8: Detail of proposed home footprint with impacts on actual 30% slopes per the August 2022 survey shown in orange. Page 8 of 110 42199 Wa lking pathway from Midland Avenue An existing informal curb cut and vehicular access is located off Midland Avenue in the northwest corner of the property. This curb cut is proposed to be removed per Engineering requirements. A simple walking pathway is proposed to provide access to the sidewalk from the property as opposed to walking down the driveway. This proposed walkway, shown in Figure 10, adds to the pedestrian experience along Midland Avenue and does not impact any slopes as illustrated in Figure 8. As demonstrated in this application the existing home is over the allowable height and floor area for the property – this project proposes a compliant single family home that meets City of Aspen requirements including the Land Use Code, Engineering Design Standards, Building Code, and all other applicable requirements, and cures existing Engineering and Fire Code non-conformities. Thank you for your consideration of this application. Please reach out to schedule a site visit or if additional information is needed for your review. Kind Regards, Sara Adams, AICP BendonAdams, LLC Figure 9: Existing photograph of curb cut and informal vehicular access at left of photograph. Figure 6: Proposed walkway to replace informal curb cut. Page 9 of 110 43200 Exhibit A 108 Midland Avenue PD Review Criteria Sec. 26.445.110. Amendments. Amendments to an approved Project Review or to an approved Detailed Review shall be reviewed according to the standards and procedures outline below. Amendments to Planned Unit Development and Specially Planned Area approvals (pre-Ordinance 36, 2013, approvals) shall also proceed according to the standards and procedures outline below and the Community Development Director shall determine the type of procedure most-applicable to the requested amendment. (d) Minor Amendment to a Project Review approval. An amendment found by the Community Development Director to be generally consistent with the allowances and limitations of a Project Review approval or which otherwise represents an insubstantial change but which does not meet the established thresholds for an insubstantial amendment, may be approved, approved with conditions or denied by the City Council, pursuant to 26.445.040(b)(2) - Step Two. An applicant may not apply for Detailed Review if an amendment is pending. Response – As per the City of Aspen issued pre-application summary, this project qualifies as a minor amendment to a Project Review. Applicable review criteria are addressed below. Sec. 26.445.050. Project Review Standards. The Project Review shall focus on the general concept for the development and shall outline any dimensional requirements that vary from those allowed in the underlying zone district. The burden shall rest upon an applicant to show the reasonableness of the development application and its conformity to the standards and procedures of this Chapter and this Title. The underlying zone district designation shall be used as a guide, but not an absolute limitation, to the dimensions which may be considered during the development review process. Any dimensional variations allowed shall be specified in the ordinance granting Project Approval. In the review of a development application for a Project Review, the Planning and Zoning Commission or the Historic Preservation Commission, as applicable, and City Council shall consider the following: (a) Compliance with Adopted Regulatory Plans. The proposed development complies with applicable adopted regulatory plans. Response – There are no applicable adopted regulatory plans for 108 Midland Avenue. (b) Development Suitability. The proposed Planned Development prohibits development on land unsuitable for development because of natural or man-made hazards affecting the property, including flooding, mudflow, debris flow, fault ruptures, landslides, rock or soil creep, rock falls, rock slides, mining activity including mine waste deposit, avalanche or snow slide areas, slopes in excess of thirty percent (30%), and any other natural or man-made hazard or condition that could harm the health, safety, or welfare of the community. Affected areas may be accepted as suitable for development if adequate mitigation techniques acceptable to the City Engineer are proposed in compliance with Title 29—Engineering Design Standards. Conceptual plans for mitigation techniques may be accepted for this standard. The City Engineer may require specific designs, mitigation techniques, and implementation timelines be defined as part of the Detailed Review and documented within a Development Agreement. Response – A single family home is currently developed on the property and is proposed to be replaced with a fully compliant new single family home. The land is suitable for development. Areas in excess of 30% slope are mitigated according to the Engineering Design Standards as demonstrated in Exhibit G. Development is primarily focused on areas that are less than 30% slope and are already developed. Page 10 of 110 44201 Exhibit A 108 Midland Avenue PD Review Criteria (c) Site Planning. The site plan is compatible with the context and visual character of the area. In meeting this standard, the following criteria shall be used: (1) The site plan responds to the site's natural characteristics and physical constraints such as steep slopes, vegetation, waterways, and any natural or man-made hazards and allows development to blend in with or enhance said features. (2) The project preserves important geologic features, mature vegetation, and structures or features of the site that have historic, cultural, visual, or ecological importance or contribute to the identity of the town. (3) Buildings are oriented to public streets and are sited to reflect the neighborhood context. Buildings and access ways are arranged to allow effective emergency, maintenance, and service vehicle access. Response – The proposed site plan is similar to the existing site plan. The proposed home is sunken into the topography to minimize any visual impacts on Midland Avenue and from Snyder Park to the north. A comprehensive landscape plan is proposed to replant trees that are proposed to be removed in order to allow a realignment of the driveway to meet current Engineering Design Standards. (d) Dimensions. All dimensions, including density, mass, and height shall be established during the Project Review. A development application may request variations to any dimensional requirement of this Title. In meeting this standard, consideration shall be given to the following criteria: (1) There exists a significant community goal to be achieved through such variations. (2) The proposed dimensions represent a character suitable for and indicative of the primary uses of the project. (3) The project is compatible with or enhances the cohesiveness or distinctive identity of the neighborhood and surrounding development patterns, including the scale and massing of nearby historical or cultural resources. (4) The number of off-street parking spaces shall be established based on the probable number of cars to be operated by those using the proposed development and the nature of the proposed uses. The availability of public transit and other transportation facilities, including those for pedestrian access and/or the commitment to utilize automobile disincentive techniques in the proposed development, and the potential for joint use of common parking may be considered when establishing a parking requirement. (5) The Project Review approval, at City Council's discretion, may include specific allowances for dimensional flexibility between Project Review and Detailed Review. Changes shall be subject to the amendment procedures of Section 26.445.110—Amendments. Response – No variances from the underlying R-15 A zone district are requested. The simple form of the proposed home is contextual to the neighborhood. Existing and proposed dimensions are in Table 1. Page 11 of 110 45202 Exhibit A 108 Midland Avenue PD Review Criteria Table 1: Dimensional Requirements for R15-A and Net Lot Area of 11,264.25 sf Existing Allowed Proposed Floor area 4,821.72 sf 4,238.5 sf *4,488.6 sf with 1 TDR 4,462.97 sf *includes landing 1 TDR Maximum height 29’ 1 1/8” 25 feet 24’ 10.5” at highest point Front setback 25 feet 25 feet 25 feet Rear setback 10 feet 10 feet 10 feet Side setback 10 feet 10 feet 10 feet Distance between buildings n/a 10 feet ~11’ 2” The proposed project brings height and floor area into compliance with the underlying zone district as demonstrated in Table 1. (e) Design Standards. The design of the proposed development is compatible with the context and visual character of the area. In meeting this standard, the following criteria shall be used: (1) The design complies with applicable design standards, including those outlined in Chapter 26.410, Residential Design Standards, Chapter 26.412, Commercial Design Standards, and Chapter 26.415, Historic Preservation. (2) The proposed materials are compatible with those called for in any applicable design standards, as well as those typically seen in the immediate vicinity. Exterior materials are finalized during Detailed Review, but review boards may set forth certain expectations or conditions related to architectural character and exterior materials during Project Review. Response – The property complies with all applicable Residential Design Standards as demonstrated in Exhibit D. Proposed materials include wood siding, a stone base, and a metal roof. The roof is solar ready as demonstrated in Exhibit D, and will comply with the newly adopted Residential Demolition and Redevelopment Standards. (f) Pedestrian, bicycle & transit facilities. The development improves pedestrian, bicycle, and transit facilities. These facilities and improvements shall be prioritized over vehicular facilities and improvements. Any vehicular access points, or curb cuts, minimize impacts on existing or proposed pedestrian, bicycle, and transit facilities. The City may require specific designs, mitigation techniques, and implementation timelines be defined as part of the Detailed Review and documented within a Development Agreement. Response – The proposed home does not impact pedestrian, bicycle, or transit facilities. The improved driveway will meet URMP requirements which will capture drainage and runoff down the driveway that impacts the pedestrian experience along Midland Avenue. (g) Engineering Design Standards. There has been accurate identification of engineering design and mitigation techniques necessary for development of the project to comply with the applicable requirements of Municipal Code Title 29—Engineering Design Standards and the City of Aspen Urban Runoff Management Plan (URMP). The City Engineer may require specific designs, mitigation techniques, and implementation timelines be defined as part of the Detailed Review and documented within a Development Agreement. Response – Exhibit G addresses all Engineering Design Standards applicable at this point in the review process. Page 12 of 110 46203 Exhibit A 108 Midland Avenue PD Review Criteria (h) Public Infrastructure and Facilities. The proposed Planned Development shall upgrade public infrastructure and facilities necessary to serve the project. Improvements shall be at the sole costs of the developer. The City Engineer may require specific designs, mitigation techniques, and implementation timelines be defined as part of the Detailed Review and documented within a Development Agreement. Response – Intent to serve letters are included in Exhibit G. This project replaces an existing home that is currently served by public infrastructure. (i) Access and Circulation. The proposed development shall have perpetual unobstructed legal vehicular access to a public way. A proposed Planned Development shall not eliminate or obstruct legal access from a public way to an adjacent property. All streets in a Planned Development retained under private ownership shall be dedicated to public use to ensure adequate public and emergency access. Security/privacy gates across access points and driveways are prohibited. Response – 108 Midland shares a curb cut and driveway with 104 Midland as required by the Ferguson Subdivision plat. A realignment of the driveway is requested to meet current Engineering Design Standards regarding slope and stormwater management, which is proposed to be reflected on an updated plat that accurately depicts the driveway location. Page 13 of 110 47204 CITY OF ASPEN COMMUNITY DEVELOPMENT DEPARTMENT City of Aspen|130 S. Galena St.|(970) 920 5090 April 2020 LAND USE APPLICATION APPLICANT: REPRESENTIVATIVE: Description: Existing and Proposed Conditions Review: Administrative or Board Review Free Market dwelling units Essential Public Facility square footage Have you included the following? FEES DUE: $ Pre-Application Conference Summary Signed Fee Agreement HOA Compliance form All items listed in checklist on PreApplication Conference Summary Name: Address: Phone#: email: Address: Phone #: email: Name: Project Name and Address: Parcel ID # (REQUIRED) BendonAdams 300 South Spring Street, Suite 202, Aspen CO 81611 970.925.2855 Required Land Use Review(s): Growth Management Quota System (GMQS) required fields: x xx x 108 Midland Ave.; Aspen, CO 81611 2737-181-26-110 Midland Properties LLC 808 N. 5th Street; Alpine, TX 79830 sara@bendonadams.com common development, planned developments, minor amendment to project review approval 5,850 Propose to realign driveway and add new development in area noted on plat to require additional review . A minor plat amendment is requested to allow the proposed development to proceed. Lodge Pillows n/a 1Net Leasable square footage n/a Affordable Housing dwelling units n/a n/a Exhibit B Page 14 of 110 48205 101 115 111 201 131126 128 130 125 1230 115 121 127 133 146 138 139 104 108 118 116 114 112 110 110 1235 1195 101 100 107 110 220 515 514 ROBINSON RDLACE T L N E C O O P E R A V EPARK AVEARDMORE DRMIDLAND AVEARDMO R E C T Date: 9/22/2021 Geographic Information Systems This map/drawing/image is a graphical representation of the features depicted and is not a legal representation. The accuracy may change depending on the enlargement or reduction. Copyright 2021 City of Aspen GIS 0 0.01 0.020.01 mi When printed at 8.5"x11" 4 Legend Urban Growth Boundary (UGB) Emissions Inventory Boundary (EIB) City of Aspen Greenline 8040 Stream Margin Hallam Bluff ESA Historic Sites Historic Districts Parcels Roads Zoomed In Scale: 1:1,226 108 Midland Ave. Vicinity Map Exhibit C Page 15 of 110 49206 Lower Level Wall Label Total Wall Area (Sq Ft) Exposed Wall Area (Sq Ft) Unexposed Wall Area 101X 59.00 0.00 59.00 102X 47.00 0.00 47.00 103X 57.00 38.00 19.00 104X 26.00 2.00 24.00 105X 22.00 2.00 20.00 106X 26.00 2.00 24.00 107X 54.00 37.00 17.00 108X 125.00 0.00 125.00 109X 60.00 0.00 60.00 110X 92.00 0.00 92.00 111X 30.00 0.00 30.00 112X 90.00 0.00 90.00 113X 199.00 185.00 14.00 114X 162.00 49.00 113.00 115X 59.00 0.00 59.00 116X 97.00 0.00 97.00 Overall Total Wall Area (Sq Ft)287.00 Exposed Wall Area (Sq Ft)41.00 % of Exposed Wall (Exposed / Total)14.29% UnExposed Wall Area (Sq Ft)246.00 % of UnExposed Wall (UnExposed / Total)85.71% Main Level Wall Label Total Wall Area (Sq Ft)Exposed Wall Area (Sq Ft) Unexposed Wall Area 201X 258.00 258.00 0.00 202X 56.00 56.00 0.00 203X 56.00 56.00 0.00 204X 76.00 76.00 0.00 205X 56.00 56.00 0.00 206X 139.00 139.00 0.00 207X 64.00 64.00 0.00 208X 97.00 84.00 13.00 209X 32.00 27.00 5.00 210X 96.00 90.00 6.00 211X 36.00 36.00 0.00 212X 112.00 112.00 0.00 213X 177.00 177.00 0.00 214X 112.00 112.00 0.00 215X 62.00 62.00 0.00 216X 104.00 93.00 0.00 Overall Total Wall Area (Sq Ft)1,533.00 Exposed Wall Area (Sq Ft)1,498.00 % of Exposed Wall (Exposed / Total)97.72% UnExposed Wall Area (Sq Ft)24.00 % of UnExposed Wall (UnExposed / Total)1.57% Subgrade Wall Area (Existing) 108 Midland Avenue, Aspen, CO 81611 Existing Lower Level Wall Calculations Lower Level Wall Label Total Wall Area (Sq Ft) Exposed Wall Area (Sq Ft) Unexposed Wall Area 101 59.00 0.00 59.00 102 47.00 0.00 47.00 103 57.00 38.00 19.00 104 26.00 2.00 24.00 105 22.00 2.00 20.00 106 26.00 2.00 24.00 107 54.00 37.00 17.00 108 125.00 0.00 125.00 109 60.00 0.00 60.00 110 92.00 0.00 92.00 111 30.00 0.00 30.00 112 90.00 0.00 90.00 113 199.00 185.00 14.00 114 162.00 49.00 113.00 115 59.00 0.00 59.00 116 97.00 0.00 97.00 Overall Total Wall Area (Sq Ft)1,205.00 Exposed Wall Area (Sq Ft)315.00 % of Exposed Wall (Exposed / Total)26.14% UnExposed Wall Area (Sq Ft)890.00 % of UnExposed Wall (UnExposed / Total)73.86% Main Level Wall Label Total Wall Area (Sq Ft)Exposed Wall Area (Sq Ft) Unexposed Wall Area 201 258.00 258.00 0.00 212 56.00 56.00 0.00 203 56.00 56.00 0.00 204 76.00 76.00 0.00 205 56.00 56.00 0.00 206 139.00 139.00 0.00 207 64.00 64.00 0.00 208 97.00 84.00 13.00 209 32.00 27.00 5.00 210 96.00 90.00 6.00 211 36.00 36.00 0.00 212 112.00 112.00 0.00 213 177.00 177.00 0.00 214 112.00 112.00 0.00 215 62.00 62.00 0.00 216 104.00 93.00 0.00 Overall Total Wall Area (Sq Ft)1,533.00 Exposed Wall Area (Sq Ft)1,498.00 % of Exposed Wall (Exposed / Total)97.72% UnExposed Wall Area (Sq Ft)24.00 % of UnExposed Wall (UnExposed / Total)1.57% Subgrade Wall Area (Proposed) 108 Midland Avenue, Aspen, CO 81611 Existing Lower Level Wall Calculations SUBGRADE EXPOSED AREA SUB-GRADE AREA Z0.06X EXISTING SUBGRADE CALCULATIONS NOT FOR CONSTRUCTION 1/30/2023COUNCIL + ANDERSSON / WISE 807 Brazos St #800 Austin TX 78701 RED 1001 Grand Ave #103 Glenwood Springs CO 81601 © These documents have been specifically prepared for 108 Midland Ave. They are not suitable for use on other projects or in other locations without the approval and participation of the architect. Reproduction prohibited without approval of the architect. 2023 108 Midland Avenue 108 Midland Ave Aspen, CO 81611 59 sq ft 47 sq ft 162 sq ft 201X 202X 203X 204X 205X 206X 209X 210X 211X 212X 213X 214X 215X 216X207X208X 96 sq ft 36 sq ft 112 sq ft326 sq ft 56 sq ft 56 sq ft 76 sq ft 56 sq ft 139 sq ft 64 sq ft 97 sq ft 32 sq ft 177 sq ft 240 sq ft 349 sq ft 140 sq ft 13 sq ft 6 sq ft 6 sq ft 59 sq ft 47 sq ft 54 sq ft 13 sq ft 26 sq ft 22 sq ft 26 sq ft 6 sq ft 11 sq ft6 sq ft8'-1/4"7'-6 1/2"8'-1/4"2'5'-6 1/2"7'-9 1/2"6'-3"7'-6 1/2"3'-5"2'-10 1/2"3'-5"7'-2 1/2"16'-6 3/4"7'-11 1/2"12'-1 3/4"3'-11 1/2"11'-11"26'-5 1/4"21'-5 1/2"7'-9 1/2"12'-11" 32'-2"6'-11 1/2"6'-11 1/2"9'-6"6'-11 1/2"17'-3 3/4"7'-11 1/2"12'-1 3/4"3'-11 1/2"11'-11"4'-6"13'-11 1/2"22'-3/4"22'-1 1/2"32'-2"12'-11" 57 sq ft 54 sq ft 30 sq ft92 sq ft60 sq ft125 sq ft 90 sq ft 199 sq ft 24 sq ft 20 sq ft 24 sq ft 7 sq ft 7 sq ft 5 sq ft 59 sq ft 97 sq ft 150 sq ft WW 38 sq ft WW 38 sq ft 101X EXISTING GRADE 102X 103X 104X 105X 106X 109X 110X 91'-6" T.O. CONC. - LOWER LEVEL 111X 112X 113X 114X 115X 116X 100'-0" T.O. STRUCT. - MAIN LEVEL 107'-10" B.O. STRUCT. - UPPER LEVEL 99'-2" B.O. STRUCT. - MAIN LEVEL 107X 108X EXISTING GRADE 91'-6" T.O. CONC. - LOWER LEVEL 100'-0" T.O. STRUCT. - MAIN LEVEL 107'-10" B.O. STRUCT. - UPPER LEVEL 99'-2" B.O. STRUCT. - MAIN LEVEL 100'-0" T.O. STRUCT. - GARAGE 125 sq ft 60 sq ft 93 sq ft 30 sq ft 90 sq ft 59 sq ft 97 sq ft PATIO 185 sq ft SCALE: 1/8" = 1'-0"1Exsting Subgrade Calculations 0 4'8'16' Page 16 of 110 50207 Z0.07X EXISTING FAR CALCULATIONS NOT FOR CONSTRUCTION 1/30/2023COUNCIL + ANDERSSON / WISE 807 Brazos St #800 Austin TX 78701 RED 1001 Grand Ave #103 Glenwood Springs CO 81601 © These documents have been specifically prepared for 108 Midland Ave. They are not suitable for use on other projects or in other locations without the approval and participation of the architect. Reproduction prohibited without approval of the architect. 2023 108 Midland Avenue 108 Midland Ave Aspen, CO 81611 DECK AREAS (Land Use Code, 26.575.020.4) THE CALCULATION OF FLOOR AREAS SHALL NOT INCLUDE DECKS OR EXTERIOR STAIRWAYS UNLESS THE AREA OF THESE FEATURES IS GREATER THAN 15% OF THE ALLOWABLE FLOOR AREA FOR THE PROPERTY. IF THE AREA OF THSES FEATURES EXCEEDS 15% OF THE PROPERTY'S ALLOWABLE FLOOR AREA, ONLY THE AREAS IN EXCESS OF 15% SHALL BE ATTRIBUTED TOWARDS THE ALLOWABLE FLOOR AREA. GARAGE EXEMPTION (Land Use Code, 26.575.020-2) IN ZONE DISTRICTS OTHER THAN THE R-15B ZONE DISTRICT, PROPERTIES CONTAINING SOLELY A SINGLE -FAMILY, TWO (2) SINGLE FAMILY RESIDENCES , OR A DUPLEX , THE GARAGE AND CARPORT AREA SHALL BE EXCLUDED FROM THE CALCULATION OF FLOOR AREA AS FOLLOWS : Table 26.575.020-2 SIZE OF GARAGE AREA EXCLUDED PER PRIMARY DWELLING UNIT (NOT INCLUDING OR CARPORT ACCESSORY DWELLING UNITS OR CARRIAGE HOUSES) FIRST 0-250 SF 100% OF THE AREA NEXT 251-500 SF 50% OF THE AREA AREAS ABOVE 500 SF NO AREA EXCLUDED PATIO AREAS (Land Use Code, 26.575.020.6) PATIOS DEVELOPED AT OR WITHIN 6 INCHES OF FINISHED GRADE SHALL NOT BE COUNTED TOWARDS FLOOR AREA. WHEN ROOF OVERHANDS OR SIMILAR ARCHITECTURAL PROJECTIONS EXCEED 4 FEET, THE ENTIRE COUNTS TOWARDS FLOOR AREA. FLOOR AREA RATIO (Land Use Code) THE TOTAL FLOOR AREA OF ALL STRUCTURES ON A LOT DIVIDED BY THE LOT AREA. FLOOR AREA (Land Use Code) THE SUM TOTAL OF THE GROSS HORIZONTAL AREAS OF EACH STORY OF THE BUILDING MEASURED FROM THE EXTERIOR WALLS OF THE BUILDING. (SEE SUPPLEMENTARY REGULATIONS - SECTION 26.575.020, CALCULATIONS AND MEASUREMENTS STAIR AND ELEVATOR EXEMPTION (Land Use Code 26.575.020.D) WHEN CALCULATING VERTICAL CIRCULATION, THE CIRCULATION ELEMENT SHALL BE COUNTED AS FOLLOWS: A) FOR STAIRS AND ELEVATORS , THE AREA OF THE FEATURE SHALL BE PROJECTED DOWN AND COUNTED ON THE LOWEROF THE TWO LEVELS CONNECTED BY THE ELEMENT AND NOT COUNTED AS FLOOR AREA ON THE TOP-MOST INTERIOR FLOOR SERVED BY THE ELEMENT. MINIMUM NET LOT AREA PER DWELLING UNIT (SQUARE FEET) ( Land Use Code 26.710.060) A) DETACHED RESIDENTIAL DWELLING: FIFTEEN THOUSAND (15,000). FOR HISTORIC LANDMARK PROPOERTIES: THREE THOUSAND (3000) B) DUPLEX: SEVEN THOUSAND, FIVE HUNDRED (7,500). FOR HISTORIC LANDMARK PROPOERTIES: THREE THOUSAND (3000) C) BED AND BREAKFAST, BOARDINGHOUSE: NO REQUIREMENT FAR FLOOR AREA GARAGE DECK EXEMPT BUILT INPLANTER FLOOR AREA (Land Use Code) THE SUM TOTAL OF THE GROSS HORIZONTAL AREAS OF EACH STORY OF THE BUILDING MEASURED FROM THE EXTERIOR WALLS OF THE BUILDING. (SEE SUPPLEMENTARY REGULATIONS - SECTION 26.575.020, CALCULATIONS AND MEASUREMENTS MINIMUM NET LOT AREA PER DWELLING UNIT (SQUARE FEET) ( Land Use Code 26.710.060) A) DETACHED RESIDENTIAL DWELLING: FIFTEEN THOUSAND (15,000). FOR HISTORIC LANDMARK PROPOERTIES: THREE THOUSAND (3000) B) DUPLEX: SEVEN THOUSAND, FIVE HUNDRED (7,500). FOR HISTORIC LANDMARK PROPOERTIES: THREE THOUSAND (3000) C) BED AND BREAKFAST, BOARDINGHOUSE: NO REQUIREMENT N16'-6 3/4"12'-1 3/4"7'-2 1/8"22'-1 1/2"7'-9 1/2" 7'-9 1/2"12'-11"11'-11"22'-1 1/2"16'-6 3/4"12'-1 3/4"7'-2 1/8"22'-1 1/2"7'-9 1/2" 7'-9 1/2"12'-11"11'-11"22'-1 1/2"14'-10 1/4"102X 103X 104X 105X 106X 107X 108X 109X 110X 111X 112X 114X 115X 116X 101X UPD I 2 2 10 10 9 9 6 6 4 4 1 1 3 3 7 7 5 5 A B C H K J G 8 8 E F 11 11 26'-5 1/4"26'-5 1/4" 113X EXISTING BASEMENT 1,168 sq ft EXISTING COVERED PATIO 349 sq ft DECK 64 sq ft EXEMPT GARAGE 250 sq ft GARAGE NON-EXEMPT 142 sq ft26'-3"32'-1 1/2"22'-1 1/2"22'-3/4"6'-11 1/2"32'-2" 6'-11 1 / 2 " 9'-6"6'-11 1/ 2 "11'-11"4'-5 1/2"13'-11 1/2"17'-3 3/4"3'-11 1/2"12'-1 3/4"7'-11 1/2" 202X 203X 204X 205X 206X 207X 208X 209X 210X 211X214X 215X 216X 201X 212X 213X DECK 96 sq ft D I 2 2 10 10 9 9 6 6 4 4 1 1 3 3 7 7 5 5 A B C H K J G 8 8 E F 11 11 GARAGE @ 50% 250 sq ft EXISTING FIRST FLOOR 1,592 sq ft EXEMPT STAIR DECK 901 sq ft D I 2 2 10 10 9 9 6 6 4 4 1 1 3 3 7 7 5 5 A B C H K J G 8 8 E F 11 11 DECK 172 sq ft EXISTING SECOND FLOOR 1,389 sq ft DECK 64 sq ft EXEMPT STAIR NET LOT AREA ZONE DISTRICT REQUIREMENTS REFERENCE MIN. GROSS LOT AREA (PER R-15A)15, 000 SF 26.710.060 MIN. NET LOT AREA (PER R-15A)15, 000 SF 26.710.060 LOT SIZE PER SURVEY 15,019.00 REFERENCE REDUCTIONS FOR AREA WITH SLOPES 0%-20% (100% OF PARCEL AREA TO BE INCLUDED IN THE NET LOT AREA)15,019 x 25%SURVEY 26.575.020-1 TOTAL AREA REDUCTIONS 15,019 - 3754.75 NET LOT AREA 11,264.25 SF ALLOWABLE FLOOR AREA 4,080 SF OF FLOOR AREA, PLUS 7 SF PER EACH ADD'L 100 SF 11,264.25 - 9,000 = 2,264.25 2,264.25/ 100 = 22.64 22.64*7 = 158.5 SF 4, 080 SF + 158.5 SF = 4,238.5 SF TOTAL ALLOWABLE AREA 4238.5 SF ALLOWABLE EXEMPT DECK 4238.5 x 15% = 635.78 FLOOR AREA BASEMENT AREA (2,048 x 11.74%) 349.9719 FIRST FLOOR AREA (2,119 x 87.10%) 2,039.54 GARAGE LEVEL (250 SF EXEMPT) 250 GARAGE LEVEL (250 x 50%)125 GARAGE LEVEL ( NOT EXEMPT 267 SF x 96.25%)256.9875 SECOND FLOOR AREA 1,389 TOTAL FLOOR AREA 4410.4969 4,410.50 - 250 = 4,160.50 SF FIRST FLOOR DECK 160 SECOND FLOOR DECK 1137 TOTAL DECK 1297 ALLOWABLE EXEMPT DECK 635.78 TOTAL DECK FLOOR AREA 1297 - 635.78 = 661.22 SF TOTAL FLOOR AREA 4,160.50 + 661.22 4,821.72 SF 4238.5 - 4,821.72 583.22 THE EXISTING HOUSE IS 583.22 SF OVER THE ALLOWABLE AREA SCALE: 1/8" = 1'-0"1Existing Basement FAR 0 4'8'16'SCALE: 1/8" = 1'-0"2Existing First Floor FAR 0 4'8'16'SCALE: 1/8" = 1'-0"3Existing Second Floor FAR 0 4'8'16' Page 17 of 110 51208 Z0.08X EXISTING NET LIVABLE CALCULATIONS NOT FOR CONSTRUCTION 1/30/2023COUNCIL + ANDERSSON / WISE 807 Brazos St #800 Austin TX 78701 RED 1001 Grand Ave #103 Glenwood Springs CO 81601 © These documents have been specifically prepared for 108 Midland Ave. They are not suitable for use on other projects or in other locations without the approval and participation of the architect. Reproduction prohibited without approval of the architect. 2023 108 Midland Avenue 108 Midland Ave Aspen, CO 81611 NET LIVABLE AREA NET LIVABLE AREA NET LIVEABLE AREA THE AREAS WITHIN A BUILDING DESIGNED TO BE USED FOR HABITATIONAND HUMAN ACTIVITY NUPD I 2 2 10 10 9 9 6 6 4 4 1 1 3 3 7 7 5 5 A B C H K J G 8 8 E F 11 11 EXISTING BASEMENT 1,026 sq ft DECK 64 sq ft DECK 96 sq ft 2 2 10 10 9 9 6 6 4 4 1 1 3 3 7 7 5 5 8 8 11 11 EXISTING FIRST FLOOR 2,121 sq ft DECK DECK DECK D I 2 2 10 10 9 9 6 6 4 4 1 1 3 3 7 7 5 5 A B C H K J G 8 8 E F 11 11 EXISTING SECOND FLOOR 1,382 sq ft SCALE: 1/8" = 1'-0"1Existing Basement Net Livable 0 4'8'16'SCALE: 1/8" = 1'-0"2Existing First Floor Net Livable 0 4'8'16'SCALE: 1/8" = 1'-0"3Existing Second Floor Net Livable 0 4'8'16' EXISTING NET LIVABLE AREA BASEMENT AREA 1,026 SF FIRST FLOOR AREA 2,121 SF SECOND FLOOR AREA 1,382 SF TOTAL EXISTING NET LIVABLE AREA 4,529 SF Page 18 of 110 52209 Z0.09X EXISTING MITIGATION CALCULATIONS NOT FOR CONSTRUCTION 1/30/2023COUNCIL + ANDERSSON / WISE 807 Brazos St #800 Austin TX 78701 RED 1001 Grand Ave #103 Glenwood Springs CO 81601 © These documents have been specifically prepared for 108 Midland Ave. They are not suitable for use on other projects or in other locations without the approval and participation of the architect. Reproduction prohibited without approval of the architect. 2023 108 Midland Avenue 108 Midland Ave Aspen, CO 81611 FLOOR AREA MITIGATION DEFINITION (Land Use Code, 26.575.020-2) FLOOR AREA SHALL BE ATTRIBUTED TO THE LOT OR PARCEL UPON WHICH IT IS DEVELOPED . IN MEASUREING A BUILDING FOR THE PURPOSES OF CALCULATING FLOOR AREAS, THERE SHALL BE INCLUDED ALL AREAS WITHIN THE SURROUNDING EXTERIOR WALLS OF THE BUILDING. WHEN MEASURING FROM THE EXTERIOR WALLS, THE MEASUREMENT SHALL BE TAKEN FROM THE EXTERIOR FACE OF FRAMING, EXTERIOR FACE OF STRUCTURAL BLOCK, EXTERIOR FACE OF STRAW BALE, OR SIMILAR EXTERIOR SURFACE OF THE NOMINAL STRUCTURE EXCLUDING SHEATHING, VAPOR BARRIER , WEATHERPROOFING MEMBRANE, EXTERIOR-MOUNTED INSULATION SYSTEMS, AND EXCLUDING ALL EXTERIOR VENEER AND SURFACE TREATMENTS SUCH AS STONE, STUCCO, BRICKS, SHINGLES, CLAPBOARDS, OR OTHER SIMILAR EXTERIOR VENEER TREATMENTS. Table 26.575.020-2 SIZE OF GARAGE AREA EXCLUDED PER PRIMARY DWELLING UNIT OR CARPORT (NOT INCLUDING ACCESSORY DWELLING UNITS OR CARRIAGE HOUSES) FIRST 0-250 SF 100% OF THE AREA NEXT 251-500 SF 50% OF THE AREA AREAS ABOVE 500 SF NO AREA EXCLUDED MITIGATION MITIGATION AREA NUPD I 2 2 10 10 9 9 6 6 4 4 1 1 3 3 7 7 5 5 A B C H K J G 8 8 E F 11 11 EXISTING BASEMENT 1,080 sq ft DECK DECK 2 2 10 10 9 9 6 6 4 4 1 1 3 3 7 7 5 5 8 8 11 11 EXISTING FIRST FLOOR 2,268 sq ft DECK DECK DECK D I 2 2 10 10 9 9 6 6 4 4 1 1 3 3 7 7 5 5 A B C H K J G 8 8 E F 11 11 EXISTING SECOND FLOOR 1,384 sq ft SCALE: 1/8" = 1'-0"1Existing Basement Mitigation 0 4'8'16'SCALE: 1/8" = 1'-0"2Existing First Floor Mitigation 0 4'8'16'SCALE: 1/8" = 1'-0"3Existing Second Floor Mitigation 0 4'8'16' EXISTING MITIGATION AREA BASEMENT AREA 1,080 SF FIRST FLOOR AREA 2,268 SF SECOND FLOOR AREA 1,384 SF TOTAL MITIGATION AREA 4,732 SF Page 19 of 110 53210 Z0.10X EXISTING GROSS FIRE AREA CALCULATIONS NOT FOR CONSTRUCTION 1/30/2023COUNCIL + ANDERSSON / WISE 807 Brazos St #800 Austin TX 78701 RED 1001 Grand Ave #103 Glenwood Springs CO 81601 © These documents have been specifically prepared for 108 Midland Ave. They are not suitable for use on other projects or in other locations without the approval and participation of the architect. Reproduction prohibited without approval of the architect. 2023 108 Midland Avenue 108 Midland Ave Aspen, CO 81611 FIRE AREA THE AGGREGATE FLOOR AREA ENCLOSED AND BOUNDED BY FIRE WALLS, EXTERIOR WALLS, OR FIRE-RESITANCE RATED HORIZONTAL ASSEMBLIES OF A BUILDING . AREAS OF THE BUILDING NOT PROVIDED WITH SURROUNDING WALLS SHALL BE INCLUDED IN THE FIRE AREA IF SUCH AREAS ARE INCLUDED WITHIN THE HORIZONTAL PROJECTION OF THE ROOF OR FLOOR ABOVE. GROSS AREA GROSS AREA COVEREDOUTDOOR AREA NCOVERED AREA 350 sq ft UPD I 2 2 10 10 9 9 6 6 4 4 1 1 3 3 7 7 5 5 A B C H K J G 8 8 E F 11 11 EXISTING BASEMENT GROSS AREA 1,093 sq ft DECK DECK 2 2 10 10 9 9 6 6 4 4 1 1 3 3 7 7 5 5 8 8 11 11 COVERED AREA 161 sq ft EXISTING FIRST FLOOR GROSS AREA 2,268 sq ft EXISTING SECOND LEVEL GROSS AREA 1,485 sq ft DECK DECK D I 2 2 10 10 9 9 6 6 4 4 1 1 3 3 7 7 5 5 A B C H K J G 8 8 E F 11 11 SCALE: 1/8" = 1'-0"1Existing Basement Gross Area 0 4'8'16'SCALE: 1/8" = 1'-0"2Existing First Floor Gross Area 0 4'8'16'SCALE: 1/8" = 1'-0"3Existing Second Floor Gross Area 0 4'8'16' GROSS FIRE AREA BASEMENT AREA 1,093 SF FIRST FLOOR AREA 2,268 SF SECOND FLOOR AREA 1,485 SF COVERED EXTERIOR AREA 511 SF TOTAL GROSS FIRE AREA 5,357 SF Page 20 of 110 54211 Z0.13X HEIGHT OVER TOPOGRAPHY NOT FOR CONSTRUCTION 1/30/2023COUNCIL + ANDERSSON / WISE 807 Brazos St #800 Austin TX 78701 RED 1001 Grand Ave #103 Glenwood Springs CO 81601 © These documents have been specifically prepared for 108 Midland Ave. They are not suitable for use on other projects or in other locations without the approval and participation of the architect. Reproduction prohibited without approval of the architect. 2023 108 Midland Avenue 108 Midland Ave Aspen, CO 81611 DEFINITIONS (SECTION 26.104.100) HEIGHT, BUILDING THE HEIGHT OF A BUILDING SHALL BE THE MAXIMUM DISTANCE POSSIBLE MEASURED VERTICALLY FROM NATURAL GRADE AT ANY POINT WITHIN THE INTERIOR OF THE BUILDING; AND FROM NATURAL OR FINISHED GRADE (WHICHEVER IS LOWER) AT ANY POINT AROUND THE PERIMETER OF THE BUILDING TO THE HIGHEST POINT OR STRUCTURE WITHIN A VERICAL PLANE. (SEE SUPPLEMENARY REGULATIONS SECTION 26.575.020, MEASURMENT AND CALCULATIONS). HEIGHT OVER TOPOGRAPHY HEIGHTS ARE MEASURED TO THE MOST RESTRICTIVE GRADE.N4 Z0.14X 1 Z0.14X 2 Z0.14X A LINE OF WALL BELOW HEIGHT OVER TOPO MEASURED PER COA MUNICIPAL CODE CHAPTER 26.575.020 EXISTINGEXISTINGEXISTING EXISTINGEXISTING DECK BELOW SCALE: 1/4" = 1'-0"1Existing Height Over Topography 0 2'4'8' A - ROOF LABEL ROOF HEIGHT ROOF HEIGHT - 8003'-1 1/8" 29'-1 1/8" SITE EXISITING - 7974'" Page 21 of 110 55212 Z0.14X HEIGHTS NOT FOR CONSTRUCTION 1/30/2023COUNCIL + ANDERSSON / WISE 807 Brazos St #800 Austin TX 78701 RED 1001 Grand Ave #103 Glenwood Springs CO 81601 © These documents have been specifically prepared for 108 Midland Ave. They are not suitable for use on other projects or in other locations without the approval and participation of the architect. Reproduction prohibited without approval of the architect. 2023 108 Midland Avenue 108 Midland Ave Aspen, CO 81611 HEIGHT OVER TOPOGRAPHY HEIGHTS ARE MEASURED TO THE MOST RESTRICTIVE GRADE. DEFINITIONS (SECTION 26.104.100) HEIGHT, BUILDING THE HEIGHT OF A BUILDING SHALL BE THE MAXIMUM DISTANCE POSSIBLE MEASURED VERTICALLY FROM NATURAL GRADE AT ANY POINT WITHIN THE INTERIOR OF THE BUILDING; AND FROM NATURAL OR FINISHED GRADE (WHICHEVER IS LOWER) AT ANY POINT AROUND THE PERIMETER OF THE BUILDING TO THE HIGHEST POINT OR STRUCTURE WITHIN A VERICAL PLANE. (SEE SUPPLEMENARY REGULATIONS SECTION 26.575.020, MEASURMENT AND CALCULATIONS). A B C D G H I J KEF H G D C B AKJIEF 10 9 8 7 6 5 4 3 2 111 29'-1 1/8"1 2 3 4 5 6 7 8 9 10 SCALE: 1/8" = 1'-0"2Existing East Elevation 0 4'8'16' SCALE: 1/8" = 1'-0"4Existing West Elevation 0 4'8'16' SCALE: 1/8" = 1'-0"1Existing North Elevation 0 4'8'16' SCALE: 1/8" = 1'-0"3Existing South Elevation 0 4'8'16' A - ROOF LABEL ROOF HEIGHT ROOF HEIGHT - 8003'-1 1/8" 29'-1 1/8" SITE EXISITING - 7974'" Page 22 of 110 56213 COVER.1 COVER SHEET NOT FOR CONSTRUCTION 1/30/2023COUNCIL + ANDERSSON / WISE 807 Brazos St #800 Austin TX 78701 RED 1001 Grand Ave #103 Glenwood Springs CO 81601 © These documents have been specifically prepared for 108 Midland Avenue. They are not suitable for use on other projects or in other locations without the approval and participation of the architect. Reproduction prohibited without approval of the architect. 2023 Haynes Residence 108 Midland Avenue Aspen, CO 81611 PROJECT SITE COUNCIL 1/30/2023 Haynes Residence 108 Midland Avenue, Aspen, CO PROJECT DIRECTORY Oddo Engineering (STRUCTURAL ENGINEER) 713 Cooper Avenue CONTACT: Robert Oddo Glenwood Springs, CO 81601 (970) 945-1006 bob@oddogws.com Red Room Design (ARCHITECT OF RECORD) 1001 Grand Ave, Suite 103 CONTACT: Steven May Glenwood Springs, CO 81601 (970) 413-3144 stevenm@redroom-design.com Midland Properties LLC (OWNER) 808 N 5th Street CONTACT: Justin Haynes Alpine, TX 79830 Giant Properties (CONTRACTOR) PO Box 2652 CONTACT: Judd Clarence Aspen, CO 81612 (970) 688-1804 judd@giantpropertiesinc.com Aspen Survey (SURVEY) 210 S Galena Street #22 CONTACT: Michael Lafferty Aspen, CO 81611 (970) 925-3816 surveyor@email.com Escape Garden Design (LANDSCAPE) 312-E AABC CONTACT: Jennifer Dolecki-Smith Aspen, CO 81611 (970) 920-3700 jennifer@escapegardendesign.com Kumar + Associates (GEOTECHNICAL ENGINEER) 5020 County Road 154 CONTACT: Dan Hardin Glenwood Springs, CO 81801 (970) 945-7988 kaglenwood@kumarusa.com Crystal River Civil (CIVIL ENGINEER) 1101 Village Road UL-4C CONTACT: Jay Engstrom Carbondale, CO 81623 (970) 404-1144 jay@crystalrivercivil.com Bendon Adams (PLANNER) 300 S Spring Street #202 CONTACT: Sara Adams Aspen, CO 81611 (970) 925-2855 sara@bendonadams.com Andersson/Wise (ARCHITECT OF DESIGN) 807 Brazos Street Suite 800 CONTACT: Ryan Oliason Austin, TX 78701 (512) 866-3523 ryan@anderssonwise.com The Renner Project (INTERIOR DESIGNER) 30118 N Lamar Boulevard CONTACT: Kimberly Renner Austin, TX 78705 (512) 917-4211 ktr@therennerproject.com Brema Engineering (MECHANICAL) 783 Second Street CONTACT: Brent Wilson Aspen CO81631 (970) 390-7673 brent@bremaengr.com PROJECT INFO JURISDICTION: City of Aspen PARCEL ID : 273718126110 LEGAL DESC: SUBDIVISION: Ferguson Exemption - LOT: 1 2015 INTERNATIONAL RESIDENTIAL CODE (IRC) 2015 INTERNATIONAL ENERGY CONSERVATION CODE (IECC) Zoning: R-15A District Climate Zone: 7 Height Limit: 25'-0" Page 23 of 110 57214 COVER.2 COVER SHEET NOT FOR CONSTRUCTION 1/30/2023COUNCIL + ANDERSSON / WISE 807 Brazos St #800 Austin TX 78701 RED 1001 Grand Ave #103 Glenwood Springs CO 81601 © These documents have been specifically prepared for 108 Midland Avenue. They are not suitable for use on other projects or in other locations without the approval and participation of the architect. Reproduction prohibited without approval of the architect. 2023 Haynes Residence 108 Midland Avenue Aspen, CO 81611 D101 A R1 I301 1 3 24 A401 101 1 A301 1 A401 1 ENTRY 101 ZONE MATCH LINEMATCH GRID ELEVATION SECTION DETAIL SECTION INTERIOR ELEVATION SPOT DOOR WINDOW W1 ASSEMBLY DETAIL CALLOUTA601 1 DRAWING REVISION SYMBOL LEGEND DRAWING INDEXMATERIAL LEGEND CONCRETE MDF EARTH SHEATHING GLASS STEEL GRAVEL STONE GWB WOOD INSULATION A AAD ATTIC ACCESS DOOR AB ANCHOR BOLT ACOUS ACOUSTICAL ACP ACOUSTIC CEILNG PANEL ACT ACOUSTIC CEILING TILE AD AREA DRAIN, ACCESS DOOR ADD ADDENDUM ADD'N ADDITION, ADDITIONAL ADJ ADJUSTABLE AFF ABOVE FINISH FLOOR AGGR AGGREGATE ALT ALTERNATE ALUM ALUMINUM ANCH ANCHOR ANOD ANODIZED AOR AREA OF REFUGE AP ACCESS PANEL APPROX APPROXIMATELY ARCH ARCHITECT, ARCHITECTURAL ASPH ASPHALT ASS'T ASSITANT ASS'Y ASSEMBLY AT ASH TRAY AUTO AUTOMATIC AUX AUXILIARY B BPL BASE PLATE BF BARRIER FREE BM BENCHMARK BOS BOTTOM OF SLAB BUR BUILT-UP ROOFING BD BOARD BEV BEVELED BITUM BITUMINOUS BKR BD BACKER BOARD BLDG BUILDING BLK'G BLOCKING BLK BLOCK BM BEAM BO BOTTOM OF BOTT BOTTOM BR'G BEARING BSM'T BASEMENT BS BOTH SIDES BSPL BACKSPLASH BTW BETWEEN C CB CATCH BASIN CC CENTER TO CENTER C HT CEILING HEIGHT CI CAST IRON CIP CAST-IN-PLACE CJ CONTROL JOINT CL CENTER LINE CMU CONCRETE MASONRY UNIT CO CLEAN OUT CP CEMENT PLASTER CT CERAMIC TILE CW COLD WATER CAB CABINET CDR CEDAR CEM CEMENT, CEMENTITIOUS CER CERAMIC CH CHANNEL CLG CEILING CLO CLOSET CLOS CLOSURE CLR CLEAR CNTR COUNTER COL COLUMN COMP COMPOSITE, COMPACTED CONC CONCRETE CONF CONFERENCE CONN CONNECT, CONNECTION CONSTR CONSTRUCTION CONT CONTINUOUS CONTR CONTRACTOR CORR CORRIDOR, CORRUGATED CPT CARPET CTR CENTER CTSK COUNTERSUNK D D DRYER DF DRINKING FOUNTAIN DL DEAD LOAD DO DOOR OPENING DP DAMPPROOFING DS DOWNSPOUT DSP DRY SRANDPIPE DW DISHWASHER DBL DOUBLE DEMO DEMOLITION, DEMOLISH DEPT DEPARTMENT DET DETAIL DIA DIAMETER DIFF DIFFERENCE, DIFFUSER DIM DIMENSION DIR DIRECTION, DIRECTORY DISP DISPENSER DISPO DISPOSAL DN DOWN DO DITTO DR DOOR DWG DRAWING DWR DRAWER ABBREVIATIONS E E EAST EF EXHAUST FAN EJ EXPANSION JOINT EO ELECTRICAL OUTLET EP ELEXTRICAL PANELBOARD ES EXIT SIGN EW EACH WAY EWC ELECTRICAL WATER COOLER EA EACH EL ELEVATION ELAS WP ELASTOMETRIC WATERPROOFING ELEC ELECTRIC, ELECTRICAL ELEV ELEVATOR ELIM ELIMINATE EMER EMERGENCY ENAM ENAMEL ENCL ENCLOSURE ENVIR ENVIRONMENT EQ EQUAL EQPT EQUIPMENT EXC EXCAVATED EXP EXPANSION EXP B EXPANSION BOLT EXPO EXPOSED EXST EXISTING EXT EXTERIOR F FA FIRE ALARM FB FLAT BAR FD FLOOR DRAIN FE FIRE EXTINGUISHER FEC FIRE EXTINGUISHER CABINET FF FINISHED FLOOR FH FIRE HYDRANT, FRAME WIDTH FHC FIRE HYDRANT CABINET FO FINISHED OPENING FOC FACE OF CONCRETE FOF FACE OF FINISH FOIC FURNISHED BY OWNER, INSTALLED BY CONTRACTOR FOM FACE OF MASONRY FP FLOOR PLAN FS FULL SIZE FSS FLOOR SERVICE SINK FAB FABRIC FAST FASTENER FDN FOUNDATION FIN FINISH FIXT FIXTURE FLASH FLASHING FLR FLOOR FRPF FIREPROOF FT FEET, FOOT FTG FOOTING FURN FURNISH, FURNISHED FURR FURRING FUT FUTURE G G GAS GC GENERAL CONTRACTOR GC GYPSUM CONCRETE GFI GROUNF FAULT INTERRUPTOR GFRC GLASS FIBER REINFORCED CONCRETE GFRG GROUND FAULT REINFORCED GYPSUM GR GUARD RAIL GSM GALVANIZED SHEET METAL GWB GYPSUM WALL BOARD GA GAUGE GALV GALVANIZED GEN GENERAL GL GLASS GND GROUND GR GRADE GYP GYPSUM H HB HOSE BIB HC HOLLOW CORE HCWD HOLLOW CORE WOOD DOOR HM HOLLOW METAL HP HIGH POINT HVAC HEATING, VENTILATION, AIR CONDITIONING HW HOT WATER HWH HOT WATER HEATER HC HANDICAPPED HD HEAD HDWD HARDWOOD HDWR HARDWARE HGR HANGER HGT HEIGHT HORIZ HORIZONTAL HR HANDRAIL HR HOUR HYD HYDRANT I ID INSIDE DIAMETER (DIM) IN or INCH OR INCHES INFO INFORMATION INSUL INSULATION OR INSULATED INT INTERIOR J JAN JANITOR JST JOIST JT JOINT K KOP KNOCK-OUT PANEL KIT KITCHEN L LH LEFT HAND LL LIVELOAD LP LOW POINT LS LIGHT SWITCH LAM LAMINATE LAV LAVATORY LKR LOCKER LT LIGHT LT WT LIGHTWEIGHT M MC MEDICINE CABINET MO MASONTRY OPENING MACH MACHINE MARB MARBLE MAS MASONRY MATL MATERIAL MAX MAXIMUM MECH MECHANICAL MED MEDIUM MED CAB MEDICINE CABINET MEMB MEMBRANE MET/MTL METAL OR METALIC MEZZ MEZZANINE MFR MANUFACTURER MH MANHOLE MICR MICROWAVE OVEN MIN MINIMUM MIR MIRROR MISC MISCELLANEOUS MTD MOUNTED MUL MULLION N N NORTH NIC NOT IN CONTRAST NTS NOT TO SCALE NO NUMBER NOM NOMINAL O OA OVERALL OC ON CENTER OD OUTSIDE DIAMETER (DIM) OH OPPOSITE HAND OH OVERHEAD OP ORIGIN POINT OBS OBSCURE OFF OFFICE OPN'G OPENING OPP OPPOSITE P LBS POUNDS P LAM PLASTIC LAMINATE PC PRE-CAST PH PANIC HARDWARE PS PROJECTION SCREEN PSF POUNDS PER SQUARE FOOT PSL PARALLEL STRAND LUMBER PT PLATE PVC POLYVINYL CHLORIDE PERF PERFORATED PERIM PERIMETER PL PLATE PLAS PLASTER PLYWD PLYWOOD PNL PANEL PR PAIR PROP PROPERTY PT POINT PTD PAINTED PTN PARTITION PVM'T PAVEMENT PWR POWER Q QT QUARRY TILE R R RISER RD ROOF DRAIN RDO ROOF DRAIN OVERFLOW RO ROUGH OPENING RAD RADIUS REF REFERENCE REFL REFLECTED REFR REFRIGERATOR REINF REINFORCED REQ'D REQUIRED RESIL RESILIENT RET RETAINING REV REVISED, REVISION RF'G ROOFING RGTR REGISTER RM ROOM RND ROUND RWD REDWOOD S S SOUTH OR SINK SC SOLID CARE SD SMOKE DETECTOR SDISP SOAP DISPENSER SF SQUARE FEET (FOOT) SJ SEALANT JOINT SAN SANITARY SCHED SCHEDULE SCR SCUPPER SECT SECTION SG SAFETY GLASS SH SHELF SHR SHOWER SHT'G SHEATHING SHT SHEET SIM SIMILAR SL SLOPE SL TD SLOPE TO DRAIN SLNT SEALANT SNGL SINGLE SP SPRINKLER SPEC SPECIFICATION SPK'R SPEAKER SQ SQUARE SST STAINLESS STEEL ST'D STANDARD STA STATION STAG'D STAGED STD STAINED STL STEEL STOR STORAGE STRUC STRUCTURAL SURF SURFACE SUSP SUSPENDED SYM SYMMETRICAL SYMBOL # POUND, NUMBER & AND @ AT L ANGLE T T TREAD T&G TONGUE & GROOVE T'HLD THRESHOLD TB TOWEL BAR TBD TO BE DETERMINED TC TRASH COMPACTOR TOC TOP OF CONCRETE TOP TOP OF PLATE TOS TOP OF STEEL TOW TOP OF WALL TP TOP OF PAVEMENT TPH TOILET PAPER HOLDER TV TELEVISION TEL TELEVISION TEMP TEMPATURE TEMP GL TEMPERED GLASS THK THICK TRTD TREATED TYP TYPICAL U UL UNDERWRITER'S LABORATIES, INC UON UNLESS OTHERWISE NOTED UNF UNFINISHED UR URINAL V V VOLT VCT VINYL COMPOSITION TILE VIF VERIFY IN FIELD VP VENEER PLASTER VAR VARIES VERT VERTICAL VEST VESTIBULE W W WEST, WEATHER WC WATER CLOSET W GRO WINDOW GROUPING WH WATER HEATER WR WATER RESISTANT WWM WELDED MESH WIRE W/ WITH W/O WITHOUT WD WOOD WDE WINDOW WP WATERPROOF(ING) WSCT WAINSCOT WT WEIGHT Y YD YARD Z0.05 Z0.06 Z0.07 Z0.08 Z0.09 Z0.10 SURVEY SUBGRADE CALCULATIONS FAR CALCULATIONS NET LIVABLE CALCULATIONS MITIGATION CALCULATIONS GROSS FIRE AREA GENERAL COVER.1 COVER.2 COVER SHEET COVER SHEET PLANS Z0.13 Z0.13 Z0.14 Z0.15 HEIGHT OVER TOPOGRAPHY HEIGHT ELEVATIONS - MH HEIGHT ELEVATIONS - OFFICE 15' BASEMENT PLAN ELEVATIONS A0.02 A0.03 A0.04 A0.05 A0.06 A0.07 A0.08 A2.01 A2.02 A2.03 A2.04 A2.05 A2.06 PROPOSED SITE AND EXTERIOR LIGHTING PLAN MH- BASEMENT PLAN MH - FIRST FLOOR PLAN MH - SECOND FLOOR PLAN MH - ROOF PLAN OFFICE - PLANS TRASH ENCLOSURE - PLANS MH - EXTERIOR ELEVATIONS MH - EXTERIOR ELEVATIONS MH - EXTERIOR ELEVATIONS MH - EXTERIOR ELEVATIONS OFFICE - EXTERIOR ELEVATIONS TRASH ENCLOSURE - EXTERIOR ELEVATIONS ZONING Page 24 of 110 58215 59216 Z0.06 SUBGRADE CALCULATIONS NOT FOR CONSTRUCTION 1/30/2023COUNCIL + ANDERSSON / WISE 807 Brazos St #800 Austin TX 78701 RED 1001 Grand Ave #103 Glenwood Springs CO 81601 © These documents have been specifically prepared for 108 Midland Avenue. They are not suitable for use on other projects or in other locations without the approval and participation of the architect. Reproduction prohibited without approval of the architect. 2023 Haynes Residence 108 Midland Avenue Aspen, CO 81611 SUBGRADE EXPOSED AREA SUB-GRADE AREA9'-3 1/4"T.O. PLY - MAIN LEVEL B.O. STRUCT - SECOND LEVEL T.O. STRUCT. CONC. - GARAGE 39 sq ft 531 sq ft WW 29 sq ft WW 11 sq ft 35 sq ft 402 sq ft 7 sq ft WW 77 sq ft WW 28 sq ft 11'-0"10'-8 7/8"35'-9 5/8"34'-10 1/2"35'-9 5/8"11'-1 7/8"7'-8"10'-2"8'-8 1/2"9'-5 1/4"9'-3 1/4"73'-5 1/2"34'-10 1/2"17'-5 1/2" 2'-11 1/2" 18'-10"4'-0"11'-9 1/2"7'-7 1/2"14'-4 1/2"24'-2 1/2"5'-4 3/4"323 sq ft 162 sq ft681 sq ft 27 sq ft 37 sq ft 109 sq ft175 sq ft 233 sq ft 273 sq ft 329 sq ft 432 sq ft 81 sq ft511 sq ft 22 sq ft 406 sq ft 329 sq ft 371 sq ft 81 sq ft T.O. STRUCT. CONC. - BASEMENT LEVEL B.O. STRUCT - FIRST LEVEL T.O. PLY - MAIN LEVEL B.O. STRUCT - SECOND LEVEL 1 2 3 4 5 6 B.O. STRUCT - GARAGE 9 10 11 12 13 14 15 16 17 18 T.O. STRUCT. CONC. - CRAWL PROPOSED GRADE T.O. STRUCT. CONC. - GARAGE EXISTING GRADE CRAWLCRAWLCRAWL 39 sq ft22 sq ft SUBGRADE WALL AREA LOWER LEVEL WALL TOTAL WALL AREA (SF) EXPOSED WALL AREA (SF) UNEXPOSED WALL AREA (SF) 1 511 105 406 2 329 0 329 3 432 61 371 4 22 0 22 5 39 0 39 6 81 0 81 OVERALL TOTAL WALL AREA (SF)1,414 EXPOSED WALL AREA (SF)166 % OF EXPOSED WALL (EXPOSED/ TOTAL)11.74% UNEXPOSED WALL AREA (SF) 1248 % OF UNEXPOSED WALL (UNEXPOSED/ TOTAL)88.26% MAIN LEVEL WALL TOTAL WALL AREA (SF) EXPOSED WALL AREA (SF) UNEXPOSED WALL AREA (SF) 9 681 674 7 10 323 288 35 11 162 162 0 12 27 27 0 13 175 175 0 14 37 37 0 15 109 109 0 16 233 233 0 17 273 273 0 18 531 129 402 OVERALL TOTAL WALL AREA (SF)2,419 EXPOSED WALL AREA (SF)2,107 % OF EXPOSED WALL (EXPOSED/ TOTAL)87.10% UNEXPOSED WALL AREA (SF) 444 % OF UNEXPOSED WALL (UNEXPOSED/ TOTAL)18.35% OFFICE MAIN LEVEL WALL TOTAL WALL AREA (SF) EXPOSED WALL AREA (SF) UNEXPOSED WALL AREA (SF) 19 142 121 21 20 182 182 0 21 142 139 3 22 182 154 28 OVERALL TOTAL WALL AREA (SF)648 EXPOSED WALL AREA (SF)596 % OF EXPOSED WALL (EXPOSED/ TOTAL)91.98% UNEXPOSED WALL AREA (SF) 52 % OF UNEXPOSED WALL (UNEXPOSED/ TOTAL)8.02% SUBGRADE WALL AREALOWER LEVEL WALL TOTAL WALL AREA (SF) EXPOSED WALL AREA (SF) UNEXPOSED WALL AREA (SF)1 511 105 40623290329343261371422022539039681081OVERALL TOTAL WALL AREA (SF)1,414EXPOSED WALL AREA (SF)166% OF EXPOSED WALL (EXPOSED/ TOTAL)11.74%UNEXPOSED WALL AREA (SF) 1248 % OF UNEXPOSED WALL (UNEXPOSED/ TOTAL)88.26% MAIN LEVEL WALL TOTAL WALL AREA (SF) EXPOSED WALL AREA (SF) UNEXPOSED WALL AREA (SF) 9 681 674 7 10 323 288 35 11 162 162 0 12 27 27 0 13 175 175 0 14 37 37 0 15 109 109 0 16 233 233 0 17 273 273 0 18 531 129 402 OVERALL TOTAL WALL AREA (SF)2,419 EXPOSED WALL AREA (SF)2,107 % OF EXPOSED WALL (EXPOSED/ TOTAL)87.10% UNEXPOSED WALL AREA (SF) 444 % OF UNEXPOSED WALL (UNEXPOSED/ TOTAL)18.35% OFFICE MAIN LEVEL WALL TOTAL WALL AREA (SF) EXPOSED WALL AREA (SF) UNEXPOSED WALL AREA (SF) 19 142 121 21 20 182 182 0 21 142 139 3 22 182 154 28 OVERALL TOTAL WALL AREA (SF)648 EXPOSED WALL AREA (SF)596 % OF EXPOSED WALL (EXPOSED/ TOTAL)91.98% UNEXPOSED WALL AREA (SF) 52 % OF UNEXPOSED WALL (UNEXPOSED/ TOTAL)8.02% SUBGRADE WALL AREALOWER LEVEL WALL TOTAL WALL AREA (SF) EXPOSED WALL AREA (SF) UNEXPOSED WALL AREA (SF)1 511 105 40623290329343261371422022539039681081OVERALL TOTAL WALL AREA (SF)1,414EXPOSED WALL AREA (SF)166% OF EXPOSED WALL (EXPOSED/ TOTAL)11.74%UNEXPOSED WALL AREA (SF) 1248% OF UNEXPOSED WALL (UNEXPOSED/ TOTAL)88.26%MAIN LEVEL WALL TOTAL WALL AREA (SF) EXPOSED WALL AREA (SF) UNEXPOSED WALL AREA (SF)9 681 674 710323288351116216201227270131751750143737015109109016233233017273273018531129402OVERALL TOTAL WALL AREA (SF)2,419EXPOSED WALL AREA (SF)2,107% OF EXPOSED WALL (EXPOSED/ TOTAL)87.10%UNEXPOSED WALL AREA (SF) 444 % OF UNEXPOSED WALL (UNEXPOSED/ TOTAL)18.35% OFFICE MAIN LEVEL WALL TOTAL WALL AREA (SF) EXPOSED WALL AREA (SF) UNEXPOSED WALL AREA (SF) 19 142 121 21 20 182 182 0 21 142 139 3 22 182 154 28 OVERALL TOTAL WALL AREA (SF)648 EXPOSED WALL AREA (SF)596 % OF EXPOSED WALL (EXPOSED/ TOTAL)91.98% UNEXPOSED WALL AREA (SF) 52 % OF UNEXPOSED WALL (UNEXPOSED/ TOTAL)8.02% 531 sq ft 402 sq ft 34'-1"15'-10" 18 3 sq ft21 sq ft 14'-7"18'-7"14'-7"18'-7"9'-9 1/4"142 sq ft 182 sq ft 142 sq ft 182 sq ft 28 sq ftT.O. CONC - OFFICE B.O. STRUCT - OFFICE 19 20 21 22 SCALE: 1/8" = 1'-0"1Subgrade Calculations 0 4'8'16' THESE PLANS ARE CONCEPTUAL IN NATURE. INDIVIDUAL BUILDING PLANS MAY VARY BUT WILL BE EVALUATED FOR COMPLIANCE WITH DESIGN STANDARDS CONTAINED WITHIN SECTION 26.575.020 OF THE CITY OF ASPEN MUNICIPAL CODE AT THE TIME OF SUBMITTING A BUILDING PERMIT APPLICATION. Page 26 of 110 60217 Z0.07 FAR CALCULATIONS NOT FOR CONSTRUCTION 1/30/2023COUNCIL + ANDERSSON / WISE 807 Brazos St #800 Austin TX 78701 RED 1001 Grand Ave #103 Glenwood Springs CO 81601 © These documents have been specifically prepared for 108 Midland Avenue. They are not suitable for use on other projects or in other locations without the approval and participation of the architect. Reproduction prohibited without approval of the architect. 2023 Haynes Residence 108 Midland Avenue Aspen, CO 81611 FAR FLOOR AREA GARAGE DECK EXEMPT BUILT INPLANTER DECK AREAS (Land Use Code, 26.575.020.4) THE CALCULATION OF FLOOR AREAS SHALL NOT INCLUDE DECKS OR EXTERIOR STAIRWAYS UNLESS THE AREA OF THESE FEATURES IS GREATER THAN 15% OF THE ALLOWABLE FLOOR AREA FOR THE PROPERTY. IF THE AREA OF THSES FEATURES EXCEEDS 15% OF THE PROPERTY'S ALLOWABLE FLOOR AREA, ONLY THE AREAS IN EXCESS OF 15% SHALL BE ATTRIBUTED TOWARDS THE ALLOWABLE FLOOR AREA. GARAGE EXEMPTION (Land Use Code, 26.575.020-2) IN ZONE DISTRICTS OTHER THAN THE R-15B ZONE DISTRICT, PROPERTIES CONTAINING SOLELY A SINGLE -FAMILY, TWO (2) SINGLE FAMILY RESIDENCES , OR A DUPLEX , THE GARAGE AND CARPORT AREA SHALL BE EXCLUDED FROM THE CALCULATION OF FLOOR AREA AS FOLLOWS : Table 26.575.020-2 SIZE OF GARAGE AREA EXCLUDED PER PRIMARY DWELLING UNIT (NOT INCLUDING OR CARPORT ACCESSORY DWELLING UNITS OR CARRIAGE HOUSES) FIRST 0-250 SF 100% OF THE AREA NEXT 251-500 SF 50% OF THE AREA AREAS ABOVE 500 SF NO AREA EXCLUDED PATIO AREAS (Land Use Code, 26.575.020.6) PATIOS DEVELOPED AT OR WITHIN 6 INCHES OF FINISHED GRADE SHALL NOT BE COUNTED TOWARDS FLOOR AREA. WHEN ROOF OVERHANDS OR SIMILAR ARCHITECTURAL PROJECTIONS EXCEED 4 FEET, THE ENTIRE COUNTS TOWARDS FLOOR AREA. FLOOR AREA RATIO (Land Use Code) THE TOTAL FLOOR AREA OF ALL STRUCTURES ON A LOT DIVIDED BY THE LOT AREA. FLOOR AREA (Land Use Code) THE SUM TOTAL OF THE GROSS HORIZONTAL AREAS OF EACH STORY OF THE BUILDING MEASURED FROM THE EXTERIOR WALLS OF THE BUILDING. (SEE SUPPLEMENTARY REGULATIONS - SECTION 26.575.020, CALCULATIONS AND MEASUREMENTS STAIR AND ELEVATOR EXEMPTION (Land Use Code 26.575.020.D) WHEN CALCULATING VERTICAL CIRCULATION, THE CIRCULATION ELEMENT SHALL BE COUNTED AS FOLLOWS: A) FOR STAIRS AND ELEVATORS , THE AREA OF THE FEATURE SHALL BE PROJECTED DOWN AND COUNTED ON THE LOWEROF THE TWO LEVELS CONNECTED BY THE ELEMENT AND NOT COUNTED AS FLOOR AREA ON THE TOP-MOST INTERIOR FLOOR SERVED BY THE ELEMENT. MINIMUM NET LOT AREA PER DWELLING UNIT (SQUARE FEET) ( Land Use Code 26.710.060) A) DETACHED RESIDENTIAL DWELLING: FIFTEEN THOUSAND (15,000). FOR HISTORIC LANDMARK PROPOERTIES: THREE THOUSAND (3000) B) DUPLEX: SEVEN THOUSAND, FIVE HUNDRED (7,500). FOR HISTORIC LANDMARK PROPOERTIES: THREE THOUSAND (3000) C) BED AND BREAKFAST, BOARDINGHOUSE: NO REQUIREMENT FLOOR AREA (Land Use Code) THE SUM TOTAL OF THE GROSS HORIZONTAL AREAS OF EACH STORY OF THE BUILDING MEASURED FROM THE EXTERIOR WALLS OF THE BUILDING. (SEE SUPPLEMENTARY REGULATIONS - SECTION 26.575.020, CALCULATIONS AND MEASUREMENTS MINIMUM NET LOT AREA PER DWELLING UNIT (SQUARE FEET) ( Land Use Code 26.710.060) A) DETACHED RESIDENTIAL DWELLING: FIFTEEN THOUSAND (15,000). FOR HISTORIC LANDMARK PROPOERTIES: THREE THOUSAND (3000) B) DUPLEX: SEVEN THOUSAND, FIVE HUNDRED (7,500). FOR HISTORIC LANDMARK PROPOERTIES: THREE THOUSAND (3000) C) BED AND BREAKFAST, BOARDINGHOUSE: NO REQUIREMENT NUPUPUPUP1 1 3 3 4 4 5 5 7 7 8 8 9 9 F E D C B A 2 2 6 6 8'-8 1/2"17'-7"4'-9"5'-5" 35'-9 5/8"11'-1 7/8"34'-10 1/2"7'-8"35'-9 5/8"10'-8 7/8"11'-0" 1 3 2 4 5 6 MECH <5'-6" BASEMENT 2,048 sq ft MECH <5'-6" G G J J 1112 10 H H I I 14'-7"18'-7" 18'-7"14'-7"UNCOVERED OUTDOOR MECH ENCLOSURE 19 20 21 22 OFFICE 271 sq ft DOWNDOWNUP 1 1 3 3 4 4 5 5 7 7 8 8 9 9 2 2 6 6 GARAGE 250 sq ft @ 50% GARAGE NON-EXEMPT 245 sq ft GARAGE EXEMPTION 250 sq ft 24'-2 1/2"34'-10 1/2"17'-5 1/2" LINE OF WINDOW WELL BELOW LINE OF WINDOW WELL BELOW LINE OF WINDOW WELL BELOW LINE OF WINDOW WELL BELOW ELEVSTAIR 73'-5 1/2"2'-11 1/2"18'-10"4'-0"11'-9 1/2"14'-4 1/2"7'-7 1/2"34'-1"15'-10"9 11 10 12 18 13 14 15 14 16 17 10 FIRST LEVEL 2,062 sq ft LINE OF OVERHANG ABOVEDOWN1 1 3 3 4 4 5 5 7 7 8 8 9 9 2 2 6 610'-3 1/2"OVERHANG.EXEMPT DECK 826 sq ft SECOND LEVEL 1,599 sq ft LINE OF OVERHANG ABOVE PLANTER PLANTERPLANTERTRASH 57 sq ft FLOOR AREA BASEMENT AREA (2,048 x 11.74%) 240.4352 FIRST FLOOR AREA (2,119 x 87.10%) 1,845.65 GARAGE LEVEL (250 SF EXEMPT) 250 GARAGE LEVEL (250 x 50%)125 GARAGE LEVEL ( NOT EXEMPT 245 SF x 87.10%)213.395 SECOND FLOOR AREA 1,599 OFFICE AREA (271 x 91.98%)249.2658 TOTAL FLOOR AREA 4522.745 4,522.745 - 250 = 4,272.75 SF SECOND FLOOR DECK 826 TOTAL DECK 826 ALLOWABLE EXEMPT DECK 635.78 TOTAL DECK FLOOR AREA 826 - 635.78 = 190.22 SF TOTAL FLOOR AREA 4,272.75 + 190.22 4,462.97 SF PURCHASE OF TDR ALLOWS FOR 250 SF 4,238.5 SF + 250 TDR = 4,488.6 SF 4,462.97 - 4,488.6 -25.63 OUR PROPOSED DESIGN IS 25.63 SF UNDER THE ALLOWABLE AREA WITH PURCHASE OF TDR ALLOWABLE FLOOR AREA 4,080 SF OF FLOOR AREA, PLUS 7 SF PER EACH ADD'L 100 SF 11,264.25 - 9,000 = 2,264.25 2,264.25/ 100 = 22.64 22.64*7 = 158.5 SF 4, 080 SF + 158.5 SF = 4,238.5 SF TOTAL ALLOWABLE AREA 4238.5 SF ALLOWABLE EXEMPT DECK 4238.5 x 15% = 635.78 NET LOT AREA ZONE DISTRICT REQUIREMENTS REFERENCE MIN. GROSS LOT AREA (PER R-15A)15, 000 SF 26.710.060 MIN. NET LOT AREA (PER R-15A)15, 000 SF 26.710.060 LOT SIZE PER SURVEY 15,019.00 REFERENCE REDUCTIONS FOR AREA WITH SLOPES 0%-20% (100% OF PARCEL AREA TO BE INCLUDED IN THE NET LOT AREA)15,019 x 25%SURVEY 26.575.020-1 TOTAL AREA REDUCTIONS 15,019 - 3754.75 NET LOT AREA 11,264.25 SF SCALE: 1/8" = 1'-0"1Basement FAR 0 4'8'16'SCALE: 1/8" = 1'-0"3Second Floor FAR 0 4'8'16'SCALE: 1/8" = 1'-0"2First Floor FAR 0 4'8'16' THESE PLANS ARE CONCEPTUAL IN NATURE. INDIVIDUAL BUILDING PLANS MAY VARY BUT WILL BE EVALUATED FOR COMPLIANCE WITH DESIGN STANDARDS CONTAINED WITHIN SECTION 26.575.020 OF THE CITY OF ASPEN MUNICIPAL CODE AT THE TIME OF SUBMITTING A BUILDING PERMIT APPLICATION. Page 27 of 110 61218 Z0.08 NET LIVABLE CALCULATIONS NOT FOR CONSTRUCTION 1/30/2023COUNCIL + ANDERSSON / WISE 807 Brazos St #800 Austin TX 78701 RED 1001 Grand Ave #103 Glenwood Springs CO 81601 © These documents have been specifically prepared for 108 Midland Avenue. They are not suitable for use on other projects or in other locations without the approval and participation of the architect. Reproduction prohibited without approval of the architect. 2023 Haynes Residence 108 Midland Avenue Aspen, CO 81611 NET LIVABLE AREA NET LIVABLE AREA NET LIVEABLE AREA THE AREAS WITHIN A BUILDING DESIGNED TO BE USED FOR HABITATIONAND HUMAN ACTIVITY NDOWNDOWNUP 1 1 3 3 4 4 5 5 7 7 8 8 9 9 1112 2 2 6 6 LINE OF WINDOW WELL BELOW LINE OF WINDOW WELL BELOW LINE OF WINDOW WELL BELOW LINE OF WINDOW WELL BELOW FIRST LEVEL 2,603 sq ft LINE OF OVERHANG ABOVEDOWN1 1 3 3 4 4 5 5 7 7 8 8 9 9 1112 2 2 6 6 PLANTER PLANTERPLANTERSECOND LEVEL 1,563 sq ft LINE OF OVERHANG ABOVE PLANTER PLANTERPLANTERUPUPUPUP1 1 3 3 4 4 5 5 7 7 8 8 9 9 F E D C B G 1112 10 A 2 2 6 6 BASEMENT 1,794 sq ft NET LIVEABLE AREA BASEMENT AREA 1,794 FIRST FLOOR AREA 2,603 SECOND FLOOR AREA 1,563 OFFICE AREA 234 TOTAL NET LIVEABLE AREA 6,194 13457 G G J J 1112 10 2 H H I I 6 OFFICE 234 sq ft SCALE: 1/8" = 1'-0"2First Floor Net liveable 0 4'8'16'SCALE: 1/8" = 1'-0"3Second Floor Net Liveable 0 4'8'16'SCALE: 1/8" = 1'-0"1Basement Net Liveable 0 4'8'16' THESE PLANS ARE CONCEPTUAL IN NATURE. INDIVIDUAL BUILDING PLANS MAY VARY BUT WILL BE EVALUATED FOR COMPLIANCE WITH DESIGN STANDARDS CONTAINED WITHIN SECTION 26.575.020 OF THE CITY OF ASPEN MUNICIPAL CODE AT THE TIME OF SUBMITTING A BUILDING PERMIT APPLICATION. Page 28 of 110 62219 Z0.09 MITIGATION CALCULATIONS NOT FOR CONSTRUCTION 1/30/2023COUNCIL + ANDERSSON / WISE 807 Brazos St #800 Austin TX 78701 RED 1001 Grand Ave #103 Glenwood Springs CO 81601 © These documents have been specifically prepared for 108 Midland Avenue. They are not suitable for use on other projects or in other locations without the approval and participation of the architect. Reproduction prohibited without approval of the architect. 2023 Haynes Residence 108 Midland Avenue Aspen, CO 81611 MITIGATION AREA MITIGATION AREA FLOOR AREA MITIGATION DEFINITION (Land Use Code, 26.575.020-2) FLOOR AREA SHALL BE ATTRIBUTED TO THE LOT OR PARCEL UPON WHICH IT IS DEVELOPED . IN MEASUREING A BUILDING FOR THE PURPOSES OF CALCULATING FLOOR AREAS, THERE SHALL BE INCLUDED ALL AREAS WITHIN THE SURROUNDING EXTERIOR WALLS OF THE BUILDING. WHEN MEASURING FROM THE EXTERIOR WALLS, THE MEASUREMENT SHALL BE TAKEN FROM THE EXTERIOR FACE OF FRAMING, EXTERIOR FACE OF STRUCTURAL BLOCK, EXTERIOR FACE OF STRAW BALE, OR SIMILAR EXTERIOR SURFACE OF THE NOMINAL STRUCTURE EXCLUDING SHEATHING, VAPOR BARRIER , WEATHERPROOFING MEMBRANE, EXTERIOR-MOUNTED INSULATION SYSTEMS, AND EXCLUDING ALL EXTERIOR VENEER AND SURFACE TREATMENTS SUCH AS STONE, STUCCO, BRICKS, SHINGLES, CLAPBOARDS, OR OTHER SIMILAR EXTERIOR VENEER TREATMENTS. Table 26.575.020-2 SIZE OF GARAGE AREA EXCLUDED PER PRIMARY DWELLING UNIT OR CARPORT (NOT INCLUDING ACCESSORY DWELLING UNITS OR CARRIAGE HOUSES) FIRST 0-250 SF 100% OF THE AREA NEXT 251-500 SF 50% OF THE AREA AREAS ABOVE 500 SF NO AREA EXCLUDED NDOWN FIRST FLOOR 2,748 sq ftDOWNUP 1 1 3 3 4 4 5 5 7 7 8 8 9 9 1112 2 2 6 6 LINE OF WINDOW WELL BELOW LINE OF WINDOW WELL BELOW LINE OF WINDOW WELL BELOW LINE OF WINDOW WELL BELOW LINE OF OVERHANG ABOVE 13457 G G J J 1112 10 2 H H I I 6 OFFICE 271 sq ft BASEMENT 2,396 sq ft UPUPUPUP1 1 3 3 4 4 5 5 7 7 8 8 9 9 F E D C B 1112 10 A 2 2 6 6DOWN1 1 3 3 4 4 5 5 7 7 8 8 9 9 1112 2 2 6 6 SECOND LEVEL 1,739 sq ft LINE OF OVERHANG ABOVE MITIGATION TOTAL BASEMENT AREA 2,048 FIRST FLOOR AREA 2,804 FIRST FLOOR OFFICE AREA 271 SECOND FLOOR AREA 1,739 6,862 SCALE: 1/8" = 1'-0"2First Floor Mitigation 0 4'8'16'SCALE: 1/8" = 1'-0"1Basement Mitigation 0 4'8'16'SCALE: 1/8" = 1'-0"3Second Floor Mitigation 0 4'8'16' THESE PLANS ARE CONCEPTUAL IN NATURE. INDIVIDUAL BUILDING PLANS MAY VARY BUT WILL BE EVALUATED FOR COMPLIANCE WITH DESIGN STANDARDS CONTAINED WITHIN SECTION 26.575.020 OF THE CITY OF ASPEN MUNICIPAL CODE AT THE TIME OF SUBMITTING A BUILDING PERMIT APPLICATION. Page 29 of 110 63220 Z0.10 GROSS FIRE AREA NOT FOR CONSTRUCTION 1/30/2023COUNCIL + ANDERSSON / WISE 807 Brazos St #800 Austin TX 78701 RED 1001 Grand Ave #103 Glenwood Springs CO 81601 © These documents have been specifically prepared for 108 Midland Avenue. They are not suitable for use on other projects or in other locations without the approval and participation of the architect. Reproduction prohibited without approval of the architect. 2023 Haynes Residence 108 Midland Avenue Aspen, CO 81611 FIRE AREA THE AGGREGATE FLOOR AREA ENCLOSED AND BOUNDED BY FIRE WALLS, EXTERIOR WALLS, OR FIRE-RESITANCE RATED HORIZONTAL ASSEMBLIES OF A BUILDING . AREAS OF THE BUILDING NOT PROVIDED WITH SURROUNDING WALLS SHALL BE INCLUDED IN THE FIRE AREA IF SUCH AREAS ARE INCLUDED WITHIN THE HORIZONTAL PROJECTION OF THE ROOF OR FLOOR ABOVE. GROSS AREA GROSS AREA COVEREDOUTDOOR AREA UPUPUPUP1 1 3 3 4 4 5 5 7 7 8 8 9 9 F E D C B 1112 10 A 2 2 6 6 BASEMENT 2,076 sq ft DOWNDOWNUP 1 1 3 3 4 4 5 5 7 7 8 8 9 9 1112 2 2 6 6 LINE OF WINDOW WELL BELOW LINE OF WINDOW WELL BELOW LINE OF WINDOW WELL BELOW LINE OF WINDOW WELL BELOW FIRST LEVEL 2,747 sq ft COVERED AREA 42 sq ft LINE OF OVERHANG ABOVEDOWN1 1 3 3 4 4 5 5 7 7 8 8 9 9 1112 2 2 6 6 SECOND LEVEL 1,673 sq ft COVERED AREA 123 sq ft LINE OF OVERHANG ABOVE GROSS FIRE AREA TOTAL BASEMENT AREA 2,076 FIRST FLOOR AREA 2,747 FIRST FLOOR OFFICE AREA 271 SECOND FLOOR AREA 1,673 COVERED EXTERIOR AREA 165 6,932 13457 G G J J 1112 10 2 H H I I 6 OFFICE 271 sq ft SCALE: 1/8" = 1'-0"1Gross Area Basement Plan 0 4'8'16'SCALE: 1/8" = 1'-0"2Gross Area First Floor Plan 0 4'8'16'SCALE: 1/8" = 1'-0"3Gross Area Second Floor Plan 0 4'8'16' THESE PLANS ARE CONCEPTUAL IN NATURE. INDIVIDUAL BUILDING PLANS MAY VARY BUT WILL BE EVALUATED FOR COMPLIANCE WITH DESIGN STANDARDS CONTAINED WITHIN SECTION 26.575.020 OF THE CITY OF ASPEN MUNICIPAL CODE AT THE TIME OF SUBMITTING A BUILDING PERMIT APPLICATION. Page 30 of 110 64221 Z0.13 HEIGHT OVER TOPOGRAPHY NOT FOR CONSTRUCTION 1/30/2023COUNCIL + ANDERSSON / WISE 807 Brazos St #800 Austin TX 78701 RED 1001 Grand Ave #103 Glenwood Springs CO 81601 © These documents have been specifically prepared for 108 Midland Avenue. They are not suitable for use on other projects or in other locations without the approval and participation of the architect. Reproduction prohibited without approval of the architect. 2023 Haynes Residence 108 Midland Avenue Aspen, CO 81611 HEIGHT OVER TOPOGRAPHY HEIGHTS ARE MEASURED TO THE MOST RESTRICTIVE GRADE. 100'-0" = 7974'-11 1 /4" DEFINITIONS (SECTION 26.104.100) HEIGHT, BUILDING THE HEIGHT OF A BUILDING SHALL BE THE MAXIMUM DISTANCE POSSIBLE MEASURED VERTICALLY FROM NATURAL GRADE AT ANY POINT WITHIN THE INTERIOR OF THE BUILDING; AND FROM NATURAL OR FINISHED GRADE (WHICHEVER IS LOWER) AT ANY POINT AROUND THE PERIMETER OF THE BUILDING TO THE HIGHEST POINT OR STRUCTURE WITHIN A VERICAL PLANE. (SEE SUPPLEMENARY REGULATIONS SECTION 26.575.020, MEASURMENT AND CALCULATIONS).10' 82 '- 8 3 /4 " A B LINE OF WALL FRAMING BELOW SIDE SETBACKREAR SETBA C K PROPE R T Y LI N E DECK BELOW MECH ENCLOSURE 797579 75 797 0 7970797579657960796579607 1/2:127 1/2:12DECK BELOW W A L K W A Y PATIO BELOW 1/4:121/4:121/4:121/4:12 1 2 A - ROOF LABEL ROOF HEIGHT ROOF HEIGHT - 7998'-3 1/8"23'-11 5/16" SITE EXISTING - 7980'-4 1/4" SITE PROPOSED (MOST RESTRICTVE) - 7975'-0" B - ROOF LABEL ROOF HEIGHT ROOF HEIGHT - 7998'-3 1/8"20'-3" SITE EXISTING - 7980'-11 1/4"" SITE PROPOSED (MOST RESTRICTVE) - 7978'-1/4" A - ROOF LABEL ROOF HEIGHTROOF HEIGHT - 7998'-3 1/8"23'-11 5/16" SITE EXISTING - 7980'-4 1/4" SITE PROPOSED (MOST RESTRICTVE) - 7975'-0" B - ROOF LABEL ROOF HEIGHT ROOF HEIGHT - 7998'-3 1/8"20'-3" SITE EXISTING - 7980'-11 1/4"" SITE PROPOSED (MOST RESTRICTVE) - 7978'-1/4" SCALE: 1/4" = 1'-0"1Height Over Topography 0 2'4'8' THESE PLANS ARE CONCEPTUAL IN NATURE. INDIVIDUAL BUILDING PLANS MAY VARY BUT WILL BE EVALUATED FOR COMPLIANCE WITH DESIGN STANDARDS CONTAINED WITHIN SECTION 26.575.020 OF THE CITY OF ASPEN MUNICIPAL CODE AT THE TIME OF SUBMITTING A BUILDING PERMIT APPLICATION. Page 31 of 110 65222 Z0.13 HEIGHT ELEVATIONS - MH NOT FOR CONSTRUCTION 1/30/2023COUNCIL + ANDERSSON / WISE 807 Brazos St #800 Austin TX 78701 RED 1001 Grand Ave #103 Glenwood Springs CO 81601 © These documents have been specifically prepared for 108 Midland Avenue. They are not suitable for use on other projects or in other locations without the approval and participation of the architect. Reproduction prohibited without approval of the architect. 2023 Haynes Residence 108 Midland Avenue Aspen, CO 81611 HEIGHT OVER TOPOGRAPHY HEIGHTS ARE MEASURED TO THE MOST RESTRICTIVE GRADE. 100'-0" = 7974'-11 1 /4" ROOF LABEL HEIGHT OVER TOPO ROOF HEIGHT A 7999'-5 7/8" ROOF HEIGHT 24'-10 1/2" 7980'-3 7/8" SITE EXISTING 7974'-7 3/8" SITE PROPOSED (MOST RESTRICTIVE) B 7999'-5 7/8" ROOF HEIGHT 24'-10 1/2" 7980'-10 5/8" SITE EXISTING 7974'-7 3/8" SITE PROPOSED (MOST RESTRICTIVE) C XXXX'-X" ROOF HEIGHT XX'-X" XXXX'-X" SITE EXISTING XX'-X" XXXX'-X" SITE PROPOSED (MOST RESTRICTIVE) XX'-X"" DEFINITIONS (SECTION 26.104.100) HEIGHT, BUILDING THE HEIGHT OF A BUILDING SHALL BE THE MAXIMUM DISTANCE POSSIBLE MEASURED VERTICALLY FROM NATURAL GRADE AT ANY POINT WITHIN THE INTERIOR OF THE BUILDING; AND FROM NATURAL OR FINISHED GRADE (WHICHEVER IS LOWER) AT ANY POINT AROUND THE PERIMETER OF THE BUILDING TO THE HIGHEST POINT OR STRUCTURE WITHIN A VERICAL PLANE. (SEE SUPPLEMENARY REGULATIONS SECTION 26.575.020, MEASURMENT AND CALCULATIONS). 1 3 4 5 7 8 926 25'-0"EXISTING GRADE PROPOSED GRADE B C D E FA 25'EXISTING GRADE PROPOSED GRADE 9 8 7 5 4 3 126 2'-6"25'-0"EXISTING GRADE PROPOS E D GRADE F E D C B A A B 25'-0"24'-10 1/2"24'-10 1/2"EXISTING GRADE PROPOSED GRADE SCALE: 1/8" = 1'-0"1MH - North Elevation 0 4'8'16'SCALE: 1/8" = 1'-0"2MH - East Elevation 0 4'8'16' SCALE: 1/8" = 1'-0"3MH - South Elevation 0 4'8'16'SCALE: 1/8" = 1'-0"4MH - West Elevation 0 4'8'16' THESE PLANS ARE CONCEPTUAL IN NATURE. INDIVIDUAL BUILDING PLANS MAY VARY BUT WILL BE EVALUATED FOR COMPLIANCE WITH DESIGN STANDARDS CONTAINED WITHIN SECTION 26.575.020 OF THE CITY OF ASPEN MUNICIPAL CODE AT THE TIME OF SUBMITTING A BUILDING PERMIT APPLICATION. Page 32 of 110 66223 Z0.14 HEIGHT ELEVATIONS - OFFICE NOT FOR CONSTRUCTION 1/30/2023COUNCIL + ANDERSSON / WISE 807 Brazos St #800 Austin TX 78701 RED 1001 Grand Ave #103 Glenwood Springs CO 81601 © These documents have been specifically prepared for 108 Midland Avenue. They are not suitable for use on other projects or in other locations without the approval and participation of the architect. Reproduction prohibited without approval of the architect. 2023 Haynes Residence 108 Midland Avenue Aspen, CO 81611 HEIGHT OVER TOPOGRAPHY HEIGHTS ARE MEASURED TO THE MOST RESTRICTIVE GRADE. 100'-0" = 7974'-11 1 /4" ROOF LABEL HEIGHT OVER TOPO ROOF HEIGHT A 7999'-5 7/8" ROOF HEIGHT 24'-10 1/2" 7980'-3 7/8" SITE EXISTING 7974'-7 3/8" SITE PROPOSED (MOST RESTRICTIVE) B 7999'-5 7/8" ROOF HEIGHT 24'-10 1/2" 7980'-10 5/8" SITE EXISTING 7974'-7 3/8" SITE PROPOSED (MOST RESTRICTIVE) C XXXX'-X" ROOF HEIGHT XX'-X" XXXX'-X" SITE EXISTING XX'-X" XXXX'-X" SITE PROPOSED (MOST RESTRICTIVE) XX'-X"" DEFINITIONS (SECTION 26.104.100) HEIGHT, BUILDING THE HEIGHT OF A BUILDING SHALL BE THE MAXIMUM DISTANCE POSSIBLE MEASURED VERTICALLY FROM NATURAL GRADE AT ANY POINT WITHIN THE INTERIOR OF THE BUILDING; AND FROM NATURAL OR FINISHED GRADE (WHICHEVER IS LOWER) AT ANY POINT AROUND THE PERIMETER OF THE BUILDING TO THE HIGHEST POINT OR STRUCTURE WITHIN A VERICAL PLANE. (SEE SUPPLEMENARY REGULATIONS SECTION 26.575.020, MEASURMENT AND CALCULATIONS).25'-0"EXISTING GRADE PROPOSED GRADE25'-0"EXISTING GRADE PROPOSED GRADE 25'-0"EXISTING GRADE PROPOSED GRADE25'-0"EXISTING GRADE PROPOSED GRADE SCALE: 1/4" = 1'-0"1Office - North Elevation 0 2'4'8'SCALE: 1/4" = 1'-0"2Office - East Elevation 0 2'4'8' SCALE: 1/4" = 1'-0"3Office - South Elevation 0 2'4'8'SCALE: 1/4" = 1'-0"4Office - West Elevation 0 2'4'8' THESE PLANS ARE CONCEPTUAL IN NATURE. INDIVIDUAL BUILDING PLANS MAY VARY BUT WILL BE EVALUATED FOR COMPLIANCE WITH DESIGN STANDARDS CONTAINED WITHIN SECTION 26.575.020 OF THE CITY OF ASPEN MUNICIPAL CODE AT THE TIME OF SUBMITTING A BUILDING PERMIT APPLICATION. Page 33 of 110 67224 A0.02 PROPOSED SITE AND EXTERIOR LIGHTING PLAN NOT FOR CONSTRUCTION 1/30/2023COUNCIL + ANDERSSON / WISE 807 Brazos St #800 Austin TX 78701 RED 1001 Grand Ave #103 Glenwood Springs CO 81601 © These documents have been specifically prepared for 108 Midland Avenue. They are not suitable for use on other projects or in other locations without the approval and participation of the architect. Reproduction prohibited without approval of the architect. 2023 Haynes Residence 108 Midland Avenue Aspen, CO 81611 SITE NOTES ① GREY BACKGROUND DENOTES EXISTING SURVEY FLOOR ELEVATIONS SECOND FLOOR - T.O. PLY. = 111'-0" (SITE = 7985'-11 1/4") FIRST FLOOR - T.O. PLY. = 100'-0" (SITE = 7974'-11 1/4") FIRST FLOOR OFFICE - T.O. CONC. = 99'-0" (SITE = 7973'-11 1/4") GARAGE - T.O. CONC. = 98'-0" (SITE = 7972'-11 1/4") MECH CRAWL - T.O. CONC. = 93'-3 3/4" (SITE = 7967'-10 1/2") BASEMENT - T.O. PLY. = 89'-11 1/4" (SITE = 7966'-0") BASEMENT - T.O. PLY. = 88'-11 1/4" (SITE = 7965'-0") BASEMENT - T.O. PLY. = 87'-11 1/4" (SITE = 7964'-0") SET REBAR & CAP LS No. 38342 FOUND MONUMENT AS DESCRIBED SITE LEGEND EASEMENT FENCE PROPOERTY LINE EXISTING GRADE PROPOSED GRADE SETBACK LINE TREE TO BE RETAINED AS REQ'D TREE TO BE REMOVED TREE LEGEND EXISTING HOUSE CONCEPTUAL LOCATION AND FOOTPRINT OF PROPOSED HOUSE LIGHTING LEGEND 26.02 IN-GRADE LIGHT FIXTURE 26.03 RECESSED WALL LIGHT N TREE TABLE TRUNK DIAMETER IN INCHES, DRIPLINE IN FEET D = DECIDUOUS, C = CONIFER TREE #TREE TYPE DIAMETER DRIPLINE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 C D C C C C C C C C C C C C C C C C C C C C C C C C C C D D D D D D D D D D D D D D D D D D D D D D D 21 12 7 10 11 12 11 11 9 11 21 10 9 6 14 13 13 10 12 10 8 9 10 13 8 7 14 12 14 17 14 18 12 10 10 11 13 15 14 12 14 12 10 9 10 7 12 10 9 13 9 20 12 12 9 10 14 9 6 6 15 10 14 10 13 8 8 7 10 10 6 8 4 7 4 5 5 9 5 7 4 5 4 6 4 4 4 4 9 9 8 10 7 8 8 8 6 9 8 11 11 10 52 53 54 55 56 57 58 59 60 61 62 63 64 65 C C C C C C C C D D D D D D 10 13 12 9 9 12 11 14 8 14 9 11 9 14 9 14 9 11 10 11 10 14 11 9 8 7 11 810'10'25 '25'39'-5.5"1 2 3 4 5 6 7 8 1 0 1 1 2 3 2 2 2 4 2 5 2 6 2 7 2 8 2 9 3 0 3 3 3 2 3 1 9 1 2 1 3 1 4 2 0 1 8 1 9 1 5 1 7 1 6 2 1 3 7 5 0 4 9 4 8 4 7 4 6 4 5 4 4 4 3 4 2 4 1 4 0 3 9 3 8 3 6 3 5 3 4 5 2 5 4 5 6 5 5 6 5 6 3 6 4 5 1 5 3 5 8 6 0 5 9 6 2 5 7 83'-4.5" PARKING SPACE (TYP.) FIRE TRUCK TURNAROUND HOSE BIB HOSE BIB HOSE BIB HOSE BIB 2.01 26.02 26.02 26.02 26.03 26.03 26.03 26.03 26.03 32.04 32.04 32.04 32.04 26.02 26.02 26.02 26.02 26.02 26.02 26.02 26.03 26.03 32.02 32.02 32.02 32.02 32.05 35.02 32.02 32.02 32.02 AUTOCOURT OPEN NO FENCE ACCESS PROPERTY LINESIDE SETBACKREAR SETBACK FRONT SETBACK SIDE SETBACKPROPERTY L INE MIDLAND AVE CONCRETE SID E W A L K MECH ENCLOSURETRASH 7980798579807 98 0 7975797579707970 797 5 79 6 5 796 0 7 9 6 5 796 0 79 6 5 797 0 796 0 797 0 797 5 79857980 104 MIDLAND AVE 10'15'46 '-9 .5 "20'-10.5" 12'-6 1/2"NSCALE: 1" = 10'1Proposed Site Plan 0 5'10'20' THESE PLANS ARE CONCEPTUAL IN NATURE. INDIVIDUAL BUILDING PLANS MAY VARY BUT WILL BE EVALUATED FOR COMPLIANCE WITH DESIGN STANDARDS CONTAINED WITHIN SECTION 26.575.020 OF THE CITY OF ASPEN MUNICIPAL CODE AT THE TIME OF SUBMITTING A BUILDING PERMIT APPLICATION. Page 34 of 110 68225 A0.02 PROPOSED SITE PLAN TREE REMOVALS NOT FOR CONSTRUCTION 5/22/2023PERMIT + ANDERSSON / WISE 807 Brazos St #800 Austin TX 78701 RED 1001 Grand Ave #103 Glenwood Springs CO 81601 © These documents have been specifically prepared for 108 Midland Avenue. They are not suitable for use on other projects or in other locations without the approval and participation of the architect. Reproduction prohibited without approval of the architect. 2023 Haynes Residence 108 Midland Avenue Aspen, CO 81611 SET REBAR & CAP LS No. 38342 FOUND MONUMENT AS DESCRIBED SITE LEGEND EASEMENT FENCE PROPOERTY LINE EXISTING GRADE PROPOSED GRADE SETBACK LINE TREE TO BE RETAINED AS REQ'D TREE TO BE REMOVED TREE LEGEND EXISTING HOUSE CONCEPTUAL LOCATION AND FOOTPRINT OF PROPOSED HOUSE LIGHTING LEGEND 26.02 IN-GRADE LIGHT FIXTURE 26.03 RECESSED WALL LIGHT SITE NOTES ① FIRST FLOOR FINISH ELEVATION 100'-0" = 7975'-0" ② SEE SHEET G0.40 AND G0.41 FOR WALL AND PARITION TYPES ③ SEE SHEET A6.00 FOR WINDOW TYPES AND SCHEDULES ④ SEE SHEET A6.50 FOR DOOR TYPES AND SCHEDULES ⑤ SEE SHEET G0.50 FOR FINISH, EQUIPMENT, AND ACCESSORIES SCHEDULE ⑥ ALL DIMENSIONS ARE TO STRUCTURAL GRID, FACE OF CONCRETE, OR FACE OF FRAMING UNLESSS NOTED OTHERWISE ⑦ ALL WINDOW LOCATION DIMENSIONS ARE REFERENCED TO THE CENTERLINE OF WINDOW UNIT. SEE SHEET A6.00 FOR ROUGH OPENING DIMENSIONS ⑧ ALL ARCHITECTURAL STEEL OR STEEL W/ WELDS EXPOSED TO VIEW SHALL BE GROOVE OR PUDDLE WELDED AND GROUND SMOOTH FOR A SEAMLESS APPEARANCE, UNLESS OTHERWISE DETAILED OR APPROVED BY ARCHITECT ⑨ ALL EXTERIOR ELECTRICAL OUTLETS AND HOSE BIBS ARE LOCATED 1'-3" A.F.F. TO CENTERLINE SITE NOTES① FIRST FLOOR FINISH ELEVATION 100'-0" = 7975'-0"② SEE SHEET G0.40 AND G0.41 FOR WALL AND PARITION TYPES③ SEE SHEET A6.00 FOR WINDOW TYPES AND SCHEDULES④ SEE SHEET A6.50 FOR DOOR TYPES AND SCHEDULES⑤ SEE SHEET G0.50 FOR FINISH, EQUIPMENT, AND ACCESSORIES SCHEDULE ⑥ ALL DIMENSIONS ARE TO STRUCTURAL GRID, FACE OF CONCRETE, OR FACE OF FRAMING UNLESSS NOTED OTHERWISE ⑦ ALL WINDOW LOCATION DIMENSIONS ARE REFERENCED TO THE CENTERLINE OF WINDOW UNIT. SEE SHEET A6.00 FOR ROUGH OPENING DIMENSIONS ⑧ ALL ARCHITECTURAL STEEL OR STEEL W/ WELDS EXPOSED TO VIEW SHALL BE GROOVE OR PUDDLE WELDED AND GROUND SMOOTH FOR A SEAMLESS APPEARANCE, UNLESS OTHERWISE DETAILED OR APPROVED BY ARCHITECT ⑨ ALL EXTERIOR ELECTRICAL OUTLETS AND HOSE BIBS ARE LOCATED 1'-3" A.F.F. TO CENTERLINE N10'10'25 '25'39'-5.5"1 2 3 4 5 6 7 8 1 0 1 1 2 3 2 2 2 4 2 5 2 6 2 7 2 8 2 9 3 0 3 4 3 3 3 1 9 1 2 1 3 1 4 2 0 1 8 1 9 1 5 1 7 1 6 2 1 3 7 5 0 4 9 4 8 4 7 4 6 4 5 4 4 4 3 4 2 4 1 4 0 3 9 3 8 3 6 3 5 5 2 5 4 5 6 5 5 6 5 6 3 6 4 5 1 5 3 5 8 6 0 5 9 6 2 5 7 83'-4.5" 3 2 PARKING SPACE (TYP.) FIRE TRUCK TURNAROUND HOSE BIB HOSE BIB HOSE BIB HOSE BIB AUTOCOURT OPEN NO FENCE ACCESS PROPERTY LINESIDE SETBACKREAR SETBACK FRONT SETBACK SIDE SETBACKPROPERTY LINE MIDLAND AVE CONCRETE SIDEWALK MECH ENCLOSURETRASH 798079857980798 0 7975797579707970 797 5 79 6 5 796 0 7 9 6 5 796 0 79 6 5 797 0 796 0 797 0 797 5 79857980 104 MIDLAND AVE 10'15'46 '-9 .5 "20'-10.5" 12'-6 1/2" KEYNOTES 2.01 EXISTING TREE: REF: SURVEY 26.02 IN GRADE LIGHT FIXTUREl REFER TO SITE PLAN & RCPs; REF: LIGHT FIXTURE SCHEDULE 26.03 RECESSED WALL LIGHT; REFER TO SITE PLAN & RCPS; REF: LIGHT FIXTURE SCHEDULE 32.02 STONE RETAINING WALL; REF: CIVIL 32.04 STONE FENCE 32.05 FIRE TRUCK TURNAROUND; REF: CIVIL SCALE: 1" = 10'1Proposed Site Plan 0 5'10'20' 69226 A0.03 MH- BASEMENT PLAN NOT FOR CONSTRUCTION 1/30/2023COUNCIL + ANDERSSON / WISE 807 Brazos St #800 Austin TX 78701 RED 1001 Grand Ave #103 Glenwood Springs CO 81601 © These documents have been specifically prepared for 108 Midland Avenue. They are not suitable for use on other projects or in other locations without the approval and participation of the architect. Reproduction prohibited without approval of the architect. 2023 Haynes Residence 108 Midland Avenue Aspen, CO 81611 SITE NOTES ① GREY BACKGROUND DENOTES EXISTING SURVEY FLOOR ELEVATIONS SECOND FLOOR - T.O. PLY. = 111'-0" (SITE = 7985'-11 1/4") FIRST FLOOR - T.O. PLY. = 100'-0" (SITE = 7974'-11 1/4") FIRST FLOOR OFFICE - T.O. CONC. = 99'-0" (SITE = 7973'-11 1/4") GARAGE - T.O. CONC. = 98'-0" (SITE = 7972'-11 1/4") MECH CRAWL - T.O. CONC. = 93'-3 3/4" (SITE = 7967'-10 1/2") BASEMENT - T.O. PLY. = 89'-11 1/4" (SITE = 7966'-0") BASEMENT - T.O. PLY. = 88'-11 1/4" (SITE = 7965'-0") BASEMENT - T.O. PLY. = 87'-11 1/4" (SITE = 7964'-0")NTHESE PLANS ARE CONCEPTUAL IN NATURE. INDIVIDUAL BUILDING PLANS MAY VARY BUT WILL BE EVALUATED FOR COMPLIANCE WITH DESIGN STANDARDS CONTAINED WITHIN SECTION 26.575.020 OF THE CITY OF ASPEN MUNICIPAL CODE AT THE TIME OF SUBMITTING A BUILDING PERMIT APPLICATION.UPUPUPUPW/DW/D1 1 3 3 4 4 5 5 7 7 8 8 9 9 F F E E D D C C B B 1112 10 A A 2 2 6 6 T.O.F.F. BASEMENT 7967'-10 1/2" 7965'-0" T.O.F.F. BASEMENT 7965'-0" 7966'-0" 7966'-0" T.O.F.F. BASEMENT 7964'-0" 7964'-0" MECHANICAL CRAWL SPACE 013 A: 237 sq ft LAUNDRY 002 A: 70 sq ft ELEVATOR 000 A: 18 sq ft HALLWAY 001 A: 68 sq ft MASSAGE 007 A: 108 sq ft POWDER 3 003 A: 83 sq ft WINE STORAGE 005 A: 97 sq ft BASEMENT LIVING ROOM 004 A: 446 sq ft GYM 008 A: 110 sq ft GUEST BATH 1 012 A: 54 sq ft GUEST BEDROOM 1 011 A: 238 sq ft GUEST BEDROOM 2 010 A: 242 sq ft GUEST BATH 2 009 A: 55 sq ft MAIN STAIR 006 A: 35 sq ft 1 A2.04 1 A2.03 1 A2.02 1 A2.01 10' 25 'REAR SETBACKFRONT SETBACKPROPERTY LINEPROPERTY LINEFRONT SETBACKSCALE: 1/4" = 1'-0"1MH - Basement Plan 0 2'4'8' Page 35 of 110 70227 A0.04 MH - FIRST FLOOR PLAN NOT FOR CONSTRUCTION 1/30/2023COUNCIL + ANDERSSON / WISE 807 Brazos St #800 Austin TX 78701 RED 1001 Grand Ave #103 Glenwood Springs CO 81601 © These documents have been specifically prepared for 108 Midland Avenue. They are not suitable for use on other projects or in other locations without the approval and participation of the architect. Reproduction prohibited without approval of the architect. 2023 Haynes Residence 108 Midland Avenue Aspen, CO 81611 SITE NOTES ① GREY BACKGROUND DENOTES EXISTING SURVEY FLOOR ELEVATIONS SECOND FLOOR - T.O. PLY. = 111'-0" (SITE = 7985'-11 1/4") FIRST FLOOR - T.O. PLY. = 100'-0" (SITE = 7974'-11 1/4") FIRST FLOOR OFFICE - T.O. CONC. = 99'-0" (SITE = 7973'-11 1/4") GARAGE - T.O. CONC. = 98'-0" (SITE = 7972'-11 1/4") MECH CRAWL - T.O. CONC. = 93'-3 3/4" (SITE = 7967'-10 1/2") BASEMENT - T.O. PLY. = 89'-11 1/4" (SITE = 7966'-0") BASEMENT - T.O. PLY. = 88'-11 1/4" (SITE = 7965'-0") BASEMENT - T.O. PLY. = 87'-11 1/4" (SITE = 7964'-0")NTHESE PLANS ARE CONCEPTUAL IN NATURE. INDIVIDUAL BUILDING PLANS MAY VARY BUT WILL BE EVALUATED FOR COMPLIANCE WITH DESIGN STANDARDS CONTAINED WITHIN SECTION 26.575.020 OF THE CITY OF ASPEN MUNICIPAL CODE AT THE TIME OF SUBMITTING A BUILDING PERMIT APPLICATION. DOWNDOWNUP 1 1 3 3 4 4 5 5 7 7 8 8 9 9 F F E E D D C C B B 1112 10 A A 2 2 6 6W/DENTRY 1 A2.04 1 A2.03 1 A2.02 1 A2.01 ENTRY 101 A: 435 sq ft GARAGE 113 A: 672 sq ft POWDER 1 112 A: 30 sq ft ELEVATOR 111 A: 18 sq ft HER MASTER BEDROOM 106 A: 252 sq ft HER MASTER BATH 108 A: 99 sq ft HER MASTER CLOSET 107 A: 148 sq ft HIS MASTER BEDROOM 103 A: 255 sq ft HIS MASTER CLOSET 104 A: 109 sq ft HIS MASTER BATH 105 A: 151 sq ft 10' 25 'REAR SETBACKFRONT SETBACKPROPERTY LINEPROPERTY LINEFRONT SETBACKMUD ROOM 110 A: 197 sq ft SCALE: 1/4" = 1'-0"1MH - First Floor Plan 0 2'4'8' Page 36 of 110 71228 A0.05 MH - SECOND FLOOR PLAN NOT FOR CONSTRUCTION 1/30/2023COUNCIL + ANDERSSON / WISE 807 Brazos St #800 Austin TX 78701 RED 1001 Grand Ave #103 Glenwood Springs CO 81601 © These documents have been specifically prepared for 108 Midland Avenue. They are not suitable for use on other projects or in other locations without the approval and participation of the architect. Reproduction prohibited without approval of the architect. 2023 Haynes Residence 108 Midland Avenue Aspen, CO 81611 SITE NOTES ① GREY BACKGROUND DENOTES EXISTING SURVEY FLOOR ELEVATIONS SECOND FLOOR - T.O. PLY. = 111'-0" (SITE = 7985'-11 1/4") FIRST FLOOR - T.O. PLY. = 100'-0" (SITE = 7974'-11 1/4") FIRST FLOOR OFFICE - T.O. CONC. = 99'-0" (SITE = 7973'-11 1/4") GARAGE - T.O. CONC. = 98'-0" (SITE = 7972'-11 1/4") MECH CRAWL - T.O. CONC. = 93'-3 3/4" (SITE = 7967'-10 1/2") BASEMENT - T.O. PLY. = 89'-11 1/4" (SITE = 7966'-0") BASEMENT - T.O. PLY. = 88'-11 1/4" (SITE = 7965'-0") BASEMENT - T.O. PLY. = 87'-11 1/4" (SITE = 7964'-0")NTHESE PLANS ARE CONCEPTUAL IN NATURE. INDIVIDUAL BUILDING PLANS MAY VARY BUT WILL BE EVALUATED FOR COMPLIANCE WITH DESIGN STANDARDS CONTAINED WITHIN SECTION 26.575.020 OF THE CITY OF ASPEN MUNICIPAL CODE AT THE TIME OF SUBMITTING A BUILDING PERMIT APPLICATION.DOWN1 1 3 3 4 4 5 5 7 7 8 8 9 9 F F E E D D C C B B 1112 10 A A 2 2 6 6 DWDW A10A111 A2.04 1 A2.03 1 A2.02 1 A2.01 BUTLER'S PANTRY 204 A: 89 sq ft POWDER 2 202 A: 30 sq ft HALLWAY 201 A: 78 sq ft BREAKFAST NOOK 205 A: 46 sq ft LIVING ROOM 206 A: 333 sq ft BAR AND MUSIC ROOM 208 A: 252 sq ft BAR TERRACE 251 A: 215 sq ft 10' 25 ' LINE OF OVERHANG ABOVE REAR SETBACKFRONT SETBACKPROPERTY LINEPROPERTY LINEFRONT SETBACKKITCHEN 203 A: 325 sq ft DINING ROOM 207 A: 202 sq ft DINING TERRACE 250 A: 325 sq ft SCALE: 1/4" = 1'-0"1MH - Second Floor Plan 0 2'4'8' Page 37 of 110 72229 A0.06 MH - ROOF PLAN NOT FOR CONSTRUCTION 1/30/2023COUNCIL + ANDERSSON / WISE 807 Brazos St #800 Austin TX 78701 RED 1001 Grand Ave #103 Glenwood Springs CO 81601 © These documents have been specifically prepared for 108 Midland Avenue. They are not suitable for use on other projects or in other locations without the approval and participation of the architect. Reproduction prohibited without approval of the architect. 2023 Haynes Residence 108 Midland Avenue Aspen, CO 81611 ROOF PLAN NOTES ① ALL NEW ROOFS TO DRAIN TO GREEN SPACE GUTTER DOWNSPOUT CORRUGATED METAL ROOF MATERIAL ASPHALT ROOF SHINGLE MEMBRANE STANDING SEAMMETAL ROOFING METAL CHIMNEY NLINE OF OVERHANG ABOVE 1 1 3 3 4 4 5 5 7 7 8 8 9 9 F F E E D D C C B B A A 2 2 6 6 SOLAR READY AREA 631 sq ft 1 A2.04 1 A2.03 1 A2.02 1 A2.01 REAR SETBACKPROPERTY LINE10' 25 ' CHIMNEY LINE OF WALL FRAMING BELOW 7:127:12REAR SETBACKPROPERTY LINEREAR SETBACKFRONT SETBACKPROPERTY LINEFRONT SETBACKSCALE: 1/4" = 1'-0"1MH - Roof Plan 0 2'4'8' THESE PLANS ARE CONCEPTUAL IN NATURE. INDIVIDUAL BUILDING PLANS MAY VARY BUT WILL BE EVALUATED FOR COMPLIANCE WITH DESIGN STANDARDS CONTAINED WITHIN SECTION 26.575.020 OF THE CITY OF ASPEN MUNICIPAL CODE AT THE TIME OF SUBMITTING A BUILDING PERMIT APPLICATION. Page 38 of 110 73230 A0.07 OFFICE - PLANS NOT FOR CONSTRUCTION 1/30/2023COUNCIL + ANDERSSON / WISE 807 Brazos St #800 Austin TX 78701 RED 1001 Grand Ave #103 Glenwood Springs CO 81601 © These documents have been specifically prepared for 108 Midland Avenue. They are not suitable for use on other projects or in other locations without the approval and participation of the architect. Reproduction prohibited without approval of the architect. 2023 Haynes Residence 108 Midland Avenue Aspen, CO 81611 SITE NOTES ① GREY BACKGROUND DENOTES EXISTING SURVEY FLOOR ELEVATIONS SECOND FLOOR - T.O. PLY. = 111'-0" (SITE = 7985'-11 1/4") FIRST FLOOR - T.O. PLY. = 100'-0" (SITE = 7974'-11 1/4") FIRST FLOOR OFFICE - T.O. CONC. = 99'-0" (SITE = 7973'-11 1/4") GARAGE - T.O. CONC. = 98'-0" (SITE = 7972'-11 1/4") MECH CRAWL - T.O. CONC. = 93'-3 3/4" (SITE = 7967'-10 1/2") BASEMENT - T.O. PLY. = 89'-11 1/4" (SITE = 7966'-0") BASEMENT - T.O. PLY. = 88'-11 1/4" (SITE = 7965'-0") BASEMENT - T.O. PLY. = 87'-11 1/4" (SITE = 7964'-0")NTHESE PLANS ARE CONCEPTUAL IN NATURE. INDIVIDUAL BUILDING PLANS MAY VARY BUT WILL BE EVALUATED FOR COMPLIANCE WITH DESIGN STANDARDS CONTAINED WITHIN SECTION 26.575.020 OF THE CITY OF ASPEN MUNICIPAL CODE AT THE TIME OF SUBMITTING A BUILDING PERMIT APPLICATION. G G J J 1112 10 H H I I 1 3 A2.05 4 A2.05 1 A2.05 2 A2.05 UNCOVERED OUTDOOR MECH ENCLOSURE 6' TALL FENCE MECHANICAL EQUIPMENT TO NOT EXCEED 30" ABOVE OR BELOW GRADE PER COA CODE OFFICE 114 A: 154 sq ft WET BAR 116 A: 28 sq ft BATHROOM 115 A: 36 sq ft SIDE SETBACK PROPERTY LINE G J 1112 H I 3 A2.05 4 A2.05 1 A2.05 LINE OF WALL FRAMING BELOW 0.25:120.25:12 0.25:120.25:12SIDE SETBACK PROPERTY LINE SCALE: 1/4" = 1'-0"1Office - First Floor Plan 0 2'4'8'SCALE: 1/4" = 1'-0"2Office - Roof Plan 0 2'4'8' Page 39 of 110 74231 MECHANICAL ENCLOSURE SECTIONS NOT FOR CONSTRUCTION 5/22/2023PERMIT + ANDERSSON / WISE 807 Brazos St #800 Austin TX 78701 RED 1001 Grand Ave #103 Glenwood Springs CO 81601 © These documents have been specifically prepared for 108 Midland Avenue. They are not suitable for use on other projects or in other locations without the approval and participation of the architect. Reproduction prohibited without approval of the architect. 2023 Haynes Residence 108 Midland Avenue Aspen, CO 81611 STONE SIDING WOOD TIMBERS AND TRIM HORIZONTAL SIDING CORRUGATED METAL ROOFING ELEVATION MATERIAL METAL CHIMNEY METAL TBD ELEVATION NOTES ① FIRST FLOOR FINISH ELEVATION 100'-0" = 7975'-0" ② SEE SHEET G0.40 AND G0.41 FOR WALL AND PARTITION TYPES ③ SEE SHEET A6.00 FOR WINDOW TYPES AND SCHEDULES ④ SEE SHEET A6.50 FOR DOOR TYPES AND SCHEDULES ⑤ SEE SHEET G0.50 FOR FINISH, EQUIPMENT, AND ACCESSORIES SCHEDULE ⑥ ALL DIMENSIONS ARE TO STRUCTURAL GRID, FACE OF CONCRETE, OR FACE OF FRAMING UNLESS NOTED OTHERWISE ⑦ ALL WINDOW LOCATION DIMENSIONS ARE REFERENCED TO THE CENTERLINE OF WINDOW UNIT. SEE SHEET A6.00 FOR ROUGH OPENING DIMENSIONS ⑧ ALL ARCHITECTURAL STEEL OR STEEL W/ WELDS EXPOSED TO VIEW SHALL BE GROOVE OR PUDDLE WELDED AND GROUND SMOOTH FOR A SEAMLESS APPEARANCE, UNLESS OTHERWISE DETAILED OR APPROVED BY ARCHITECT ⑨ ALL EXTERIOR ELECTRICAL OUTLETS AND HOSE BIBS ARE LOCATED 1'-3" A.F.F. TO CENTERLINE ① FIRST FLOOR FINISH ELEVATION 100'-0" = 7975'-0"② SEE SHEET G0.40 AND G0.41 FOR WALL AND PARTITION TYPES③ SEE SHEET A6.00 FOR WINDOW TYPES AND SCHEDULES ④ SEE SHEET A6.50 FOR DOOR TYPES AND SCHEDULES ⑤ SEE SHEET G0.50 FOR FINISH, EQUIPMENT, AND ACCESSORIES SCHEDULE ⑥ ALL DIMENSIONS ARE TO STRUCTURAL GRID, FACE OF CONCRETE, OR FACE OF FRAMING UNLESS NOTED OTHERWISE ⑦ ALL WINDOW LOCATION DIMENSIONS ARE REFERENCED TO THE CENTERLINE OF WINDOW UNIT. SEE SHEET A6.00 FOR ROUGH OPENING DIMENSIONS ⑧ ALL ARCHITECTURAL STEEL OR STEEL W/ WELDS EXPOSED TO VIEW SHALL BE GROOVE OR PUDDLE WELDED AND GROUND SMOOTH FOR A SEAMLESS APPEARANCE, UNLESS OTHERWISE DETAILED OR APPROVED BY ARCHITECT ⑨ ALL EXTERIOR ELECTRICAL OUTLETS AND HOSE BIBS ARE LOCATED 1'-3" A.F.F. TO CENTERLINE 1'-6"12'-11"1'-6"6'-0"STONE FENCE STONE FENCE MECHANICAL ENCLOSUREBIKE STORAGE 1'-6"16'-10 1/2"6'-0"STONE FENCE MECHANICAL ENCLOSURE OFFICE SCALE: 1/2" = 1'-0"1Mech Enclosure N-S Section 0 1'2'4' SCALE: 1/2" = 1'-0"2Mech Enclosure E-W Section 0 1'2'4' 75232 A0.08 TRASH ENCLOSURE - PLANS NOT FOR CONSTRUCTION 1/30/2023COUNCIL + ANDERSSON / WISE 807 Brazos St #800 Austin TX 78701 RED 1001 Grand Ave #103 Glenwood Springs CO 81601 © These documents have been specifically prepared for 108 Midland Avenue. They are not suitable for use on other projects or in other locations without the approval and participation of the architect. Reproduction prohibited without approval of the architect. 2023 Haynes Residence 108 Midland Avenue Aspen, CO 81611 SITE NOTES ① GREY BACKGROUND DENOTES EXISTING SURVEY FLOOR ELEVATIONS SECOND FLOOR - T.O. PLY. = 111'-0" (SITE = 7985'-11 1/4") FIRST FLOOR - T.O. PLY. = 100'-0" (SITE = 7974'-11 1/4") FIRST FLOOR OFFICE - T.O. CONC. = 99'-0" (SITE = 7973'-11 1/4") GARAGE - T.O. CONC. = 98'-0" (SITE = 7972'-11 1/4") MECH CRAWL - T.O. CONC. = 93'-3 3/4" (SITE = 7967'-10 1/2") BASEMENT - T.O. PLY. = 89'-11 1/4" (SITE = 7966'-0") BASEMENT - T.O. PLY. = 88'-11 1/4" (SITE = 7965'-0") BASEMENT - T.O. PLY. = 87'-11 1/4" (SITE = 7964'-0")NTHESE PLANS ARE CONCEPTUAL IN NATURE. INDIVIDUAL BUILDING PLANS MAY VARY BUT WILL BE EVALUATED FOR COMPLIANCE WITH DESIGN STANDARDS CONTAINED WITHIN SECTION 26.575.020 OF THE CITY OF ASPEN MUNICIPAL CODE AT THE TIME OF SUBMITTING A BUILDING PERMIT APPLICATION. 1 A2.06 2 A2.06 TRASH A: 48 sq ft 1 A2.06 2 A2.06 SCALE: 1/4" = 1'-0"1Trash Enclosure - Floor Plan 0 2'4'8' SCALE: 1/4" = 1'-0"2Trash Enclosure - Roof Plan 0 2'4'8' Page 40 of 110 76233 A2.01 MH - EXTERIOR ELEVATIONS NOT FOR CONSTRUCTION 1/30/2023COUNCIL + ANDERSSON / WISE 807 Brazos St #800 Austin TX 78701 RED 1001 Grand Ave #103 Glenwood Springs CO 81601 © These documents have been specifically prepared for 108 Midland Avenue. They are not suitable for use on other projects or in other locations without the approval and participation of the architect. Reproduction prohibited without approval of the architect. 2023 Haynes Residence 108 Midland Avenue Aspen, CO 81611 STONE SIDING WOOD TIMBERS AND TRIM HORIZONTAL SIDING CORRUGATED METAL ROOFING ELEVATION MATERIAL METAL CHIMNEY METAL TBD 1 2 3 4 5 6 7 8 9 EXISTING GRADE PROPOSED GRADE SCALE: 1/4" = 1'-0"1MH - North Elevation 0 2'4'8' THESE PLANS ARE CONCEPTUAL IN NATURE. INDIVIDUAL BUILDING PLANS MAY VARY BUT WILL BE EVALUATED FOR COMPLIANCE WITH DESIGN STANDARDS CONTAINED WITHIN SECTION 26.575.020 OF THE CITY OF ASPEN MUNICIPAL CODE AT THE TIME OF SUBMITTING A BUILDING PERMIT APPLICATION. Page 41 of 110 77234 A2.02 MH - EXTERIOR ELEVATIONS NOT FOR CONSTRUCTION 1/30/2023COUNCIL + ANDERSSON / WISE 807 Brazos St #800 Austin TX 78701 RED 1001 Grand Ave #103 Glenwood Springs CO 81601 © These documents have been specifically prepared for 108 Midland Avenue. They are not suitable for use on other projects or in other locations without the approval and participation of the architect. Reproduction prohibited without approval of the architect. 2023 Haynes Residence 108 Midland Avenue Aspen, CO 81611 STONE SIDING WOOD TIMBERS AND TRIM HORIZONTAL SIDING CORRUGATED METAL ROOFING ELEVATION MATERIAL METAL CHIMNEY METAL TBD A B C D E F 30"EXISTING GRADE PROPOSED GRADE SCALE: 1/4" = 1'-0"1MH - East Elevation 0 2'4'8' THESE PLANS ARE CONCEPTUAL IN NATURE. INDIVIDUAL BUILDING PLANS MAY VARY BUT WILL BE EVALUATED FOR COMPLIANCE WITH DESIGN STANDARDS CONTAINED WITHIN SECTION 26.575.020 OF THE CITY OF ASPEN MUNICIPAL CODE AT THE TIME OF SUBMITTING A BUILDING PERMIT APPLICATION. Page 42 of 110 78235 A2.03 MH - EXTERIOR ELEVATIONS NOT FOR CONSTRUCTION 1/30/2023COUNCIL + ANDERSSON / WISE 807 Brazos St #800 Austin TX 78701 RED 1001 Grand Ave #103 Glenwood Springs CO 81601 © These documents have been specifically prepared for 108 Midland Avenue. They are not suitable for use on other projects or in other locations without the approval and participation of the architect. Reproduction prohibited without approval of the architect. 2023 Haynes Residence 108 Midland Avenue Aspen, CO 81611 STONE SIDING WOOD TIMBERS AND TRIM HORIZONTAL SIDING CORRUGATED METAL ROOFING ELEVATION MATERIAL METAL CHIMNEY METAL TBD 9 8 7 6 5 4 3 2 1 9'-0"1'-0"9'-0" 19'-0" SCALE: 1/4" = 1'-0"1MH - South Elevation 0 2'4'8' THESE PLANS ARE CONCEPTUAL IN NATURE. INDIVIDUAL BUILDING PLANS MAY VARY BUT WILL BE EVALUATED FOR COMPLIANCE WITH DESIGN STANDARDS CONTAINED WITHIN SECTION 26.575.020 OF THE CITY OF ASPEN MUNICIPAL CODE AT THE TIME OF SUBMITTING A BUILDING PERMIT APPLICATION. Page 43 of 110 79236 A2.04 MH - EXTERIOR ELEVATIONS NOT FOR CONSTRUCTION 1/30/2023COUNCIL + ANDERSSON / WISE 807 Brazos St #800 Austin TX 78701 RED 1001 Grand Ave #103 Glenwood Springs CO 81601 © These documents have been specifically prepared for 108 Midland Avenue. They are not suitable for use on other projects or in other locations without the approval and participation of the architect. Reproduction prohibited without approval of the architect. 2023 Haynes Residence 108 Midland Avenue Aspen, CO 81611 STONE SIDING WOOD TIMBERS AND TRIM HORIZONTAL SIDING CORRUGATED METAL ROOFING ELEVATION MATERIAL METAL CHIMNEY METAL TBD F E D C B A EXISTING GRADE PROPOSED GRADE SCALE: 1/4" = 1'-0"1MH - West Elevation 0 2'4'8' THESE PLANS ARE CONCEPTUAL IN NATURE. INDIVIDUAL BUILDING PLANS MAY VARY BUT WILL BE EVALUATED FOR COMPLIANCE WITH DESIGN STANDARDS CONTAINED WITHIN SECTION 26.575.020 OF THE CITY OF ASPEN MUNICIPAL CODE AT THE TIME OF SUBMITTING A BUILDING PERMIT APPLICATION. Page 44 of 110 80237 A2.05 OFFICE - EXTERIOR ELEVATIONS NOT FOR CONSTRUCTION 1/30/2023COUNCIL + ANDERSSON / WISE 807 Brazos St #800 Austin TX 78701 RED 1001 Grand Ave #103 Glenwood Springs CO 81601 © These documents have been specifically prepared for 108 Midland Avenue. They are not suitable for use on other projects or in other locations without the approval and participation of the architect. Reproduction prohibited without approval of the architect. 2023 Haynes Residence 108 Midland Avenue Aspen, CO 81611 STONE SIDING WOOD TIMBERS AND TRIM HORIZONTAL SIDING CORRUGATED METAL ROOFING ELEVATION MATERIAL METAL CHIMNEY METAL TBDEXISTING GRADE PROPOSED GRADE EXISTING GRADE PROPOSED GRADE EXISTING GRADE PROPOSED GRADE EXISTING GRADE PROPOSED GRADE SCALE: 1/4" = 1'-0"3Office - South Elevation 0 2'4'8'SCALE: 1/4" = 1'-0"4Office - West Elevation 0 2'4'8' SCALE: 1/4" = 1'-0"1Office - North Elevation 0 2'4'8'SCALE: 1/4" = 1'-0"2Office - East Elevation 0 2'4'8' THESE PLANS ARE CONCEPTUAL IN NATURE. INDIVIDUAL BUILDING PLANS MAY VARY BUT WILL BE EVALUATED FOR COMPLIANCE WITH DESIGN STANDARDS CONTAINED WITHIN SECTION 26.575.020 OF THE CITY OF ASPEN MUNICIPAL CODE AT THE TIME OF SUBMITTING A BUILDING PERMIT APPLICATION. Page 45 of 110 81238 A2.06 TRASH ENCLOSURE - EXTERIOR ELEVATIONS NOT FOR CONSTRUCTION 1/30/2023COUNCIL + ANDERSSON / WISE 807 Brazos St #800 Austin TX 78701 RED 1001 Grand Ave #103 Glenwood Springs CO 81601 © These documents have been specifically prepared for 108 Midland Avenue. They are not suitable for use on other projects or in other locations without the approval and participation of the architect. Reproduction prohibited without approval of the architect. 2023 Haynes Residence 108 Midland Avenue Aspen, CO 81611 STONE SIDING WOOD TIMBERS AND TRIM HORIZONTAL SIDING CORRUGATED METAL ROOFING ELEVATION MATERIAL METAL CHIMNEY METAL TBD 8'-0 5/16"SCALE: 1/4" = 1'-0"1Trash Enclosure - North Elevation 0 2'4'8'SCALE: 1/4" = 1'-0"2Trash Enclosure - West Elevation 0 2'4'8' Page 46 of 110 82239 FASCIA WINDOW FRAMES WOOD SIDING METAL ROOF Page 47 of 110 83240 Residential Design Standards Administrative Compliance Review Applicant Checklist - Single Family and Duplex Standard Complies Alternative Compliance N/A Sheet #(s)/Notes B.1.Articulation of Building Mass (Non-flexible) B.2.Building Orientation (Flexible) B.3.Build-to Requirement (Flexible) B.4.One Story Element (Flexible) C.1.Garage Access (Non-flexible) C.2.Garage Placement (Non-flexible) C.3.Garage Dimensions (Flexible) Instructions: Please fill out the checklist below, marking whether the proposed design complies with the applicable standard as written or is requesting Alternative Compliance (only permitted for Flexible standards). Also include the sheet #(s) demonstrating the applicable standard. If a standard does not apply, please mark N/A and include in the Notes section why it does not apply. If Alternative Compliance is requested for a Flexible standard, include in the Notes section how the proposed design meets the intent of the standard(s). Additional sheets/graphics may be attached. Disclaimer: This application is only valid for the attached design. If any element of the design subject to Residential Design Standards changes prior to or during building permit review, the applicant shall be required to apply for a new Administrative Compliance Review. Address: Parcel ID: Zone District/PD: Representative: Email: Phone: Page 1 of 2Page 48 of 110 84241 Standard Complies Alternative Compliance N/A Sheet #(s)/Notes C.4.Garage Door Design (Flexible) D.1.Entry Connection (Non-flexible) D.2.Door Height (Flexible) D.3.Entry Porch (Flexible) E.1.Principle Window (Flexible) E.2.Window Placement (Flexible) E.3.Nonorthogonal Window Limit (Flexible) E.4.Lightwell/Stairwell Location (Flexible) E.5.Materials (Flexible) Disclaimer: This application is only valid for the attached design. If any element of the design subject to Residential Design Standards changes prior to or during building permit review, the applicant shall be required to apply for a new Administrative Compliance Review. Page 2 of 2 Residential Design Standards Administrative Compliance Review Applicant Checklist - Single Family and Duplex Page 49 of 110 85242 86243 X T X T X T X T X TXTXT XT XT XT X T X TXTXTXTXT XTXTXTXTXTXTXTXTXTS GE SNYDER PARK FERGUSON EXEMPTION LOT A OF LOT 4 SPLIT E X U E X U E X U EXUEXUEXU E XU E XU E X U E X U E X U EXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUE XUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEGT C XWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWSXWSXWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWXWXWXWXW S XW S XC XC XC XC XCXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGX G X G X G X G X G X G X G XG XG XG XG XG XG XG XG XGXGXGXGXGXG XG XG XG XG XG XG X G XGXGXG XG XG XG XG XG XG XG XG XG XG XG XG XGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXSSXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXCXCXCXCXCXCXCXC XC XC XC XC XC XC XC XC XC XC XC XC T E WS WS WS WS WS WSWSWSWSWSWSWSWSWSWS WS WS WS WS WSWSWSWSWSWSWSWSWSWSWSWSWS WS WS GGGGGG G G GGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGWS WS WS WS WS WS WS C C C C C CGGGGGGGGGGGG SSSS SSSSSSSSSSSSSS SS SS SS SS SS SS SS SS SS SS TTT TTTTTTTT T T T T T T T T T UEUEU E UEUEUEUEUEUEUE UE UE UE UE UE UE UE UEUE XSSXSSXSSXSSXSSXSSXSSXSS XSS XSS XSS XSS XSS XSS XSS OC< 0 00 0 98PC: 0+02.69PT: 0+05.80PC: 0+13.84PT: 0+28.00PC: 0+37.74PT: 0+68. 2 2 PC: 0+77. 3 6 PT: 0+90.51Start WalkwaySTA:0+00.00N:5221.70E:4722.94End WalkwaySTA:0+98.22N:5168.77E:4797.151002002 08 PT : 0 + 5 0 . 6 1 P C : 0 + 7 0 . 1 6 P T : 1 + 0 0 . 9 1 P C : 1 + 2 4 . 6 1 PT: 1 + 3 9 . 0 7 End 1 0 8 M i d l a n d D r i v e w a y A l i g n m e n t STA : 2 + 0 7 . 7 5 N:51 5 1 . 1 4 E:47 4 2 . 4 7 100200PC: 0 + 4 5 . 5 4 PT: 1 + 9 6 . 2 6 PC: 2 + 1 7 . 0 2 PT: 2+ 8 0 . 0 2 2010020200202 97 PC: 2 0 0 + 6 4 . 1 3 PT: 2 0 2 + 1 6 . 4 1 PC: 2 0 2 + 3 7 . 1 7 End Fl o w L i n e A l i g n m e n t STA:2 0 2 + 9 7 . 3 0 N:522 9 . 3 7 E:472 2 . 7 8 12.0% 12.7% 0 . 7% 00 10100101 25 P T : 1 0 1 + 0 7 . 7 7 Start 104 Midland Driveway AlignmentSTA:100+00.00E:4607.42E n d 1 0 4 M i d l a n d D r i v e w a y A l i g n m e n t S T A : 1 0 1 + 2 5 . 0 0 N: 5 0 3 5 . 3 3 E: 4 7 2 0 . 8 1 Structure - (3) Structure - (4)Pipe - (2 ) Structure - (5)Pipe - (3)Structure - (6) Pipe - (4) Structure - (7)Pipe - (5)Structure - (8) Structure - (9) Pipe - ( 6 ) Structure - (10) Structure - (11)Pipe - (7) Structure - (12) Pip e - ( 8 )Pipe - (9 ) Structure - (14)Pipe - (10)Structure - (15) Structure - (16)Pipe - (11)Pipe - (12) Structure - (17) Structure - (18) Zone 2/2a 7960'-0" 7965'-0" 7970'-0" 7975'-0" 7 9 6 5 ' - 0 " 7 9 7 0 ' - 0 " 7980'-0" 7985'-0" 7975'-0" 7980'-0" 7960'-0" 7965'-0" 7970'-0"RE A R Y A R D S E T B A C K 10' - 0 "SIDE YARD SETBACK10'-0"FRO N T Y A R D S E T B A C K 25'-0 "SIDE YARD SETBACK10'-0"TRA S H EN C L O S U R E MECHANICAL ENCLOSURE 7975'-0" 7973'-0" 7975'-0"PROPERTY LINEPROPERTY LINEPR O P E R T Y L I N E PROP E R T Y L I N E BIKESTORAGEMIDLAND AVE75+ +77 75++74.95 +73.95 795 7 ( 5 7 ) +79 +81.5 +84 +81.5 +80.5 +83.5+86+80+82.52 X FRONT YARD SETBACK71 Top 72? Bottom 70.75? +74.85 +71.35 +70 +67 +66.7+64.2+63.9+61.9Zone 1 Zone 4 Zone 4 Zone 4 Zone 4 Zone 8 Key Existing Evergreen to Remain Existing Deciduous to Remain Proposed 10-16' Evergreen (Zone 7) Proposed 2.5-4" Deciduous (Zone 6) Proposed #2 or #5 Deciduous (Zone 3) Proposed 4-6' Deciduous (Zone 3) Proposed Accent Specialty Evergreen (Zone 3) Perennials and Ground Covers (Garden Zone 2 and 2a) 10 0 10 20 30 Scale 1" = 10'Page 51 of 110 87244 Key Existing Evergreen to Remain Existing Deciduous to Remain Proposed 10-16' Evergreen (Zone 7) Proposed 2.5-4" Deciduous (Zone 6) Proposed #2 or #5 Deciduous (Zone 3) Proposed 4-6' Deciduous (Zone 3) Proposed Accent Specialty Evergreen (Zone 3) Perennials and Ground Covers (Garden Zone 2 and 2a) X T X T X T X T X TXTXT XT XT XT X T X TXTXTXTXT XTXTXTXTXTXTXTXTXTS GE SNYDER PARK FERGUSON EXEMPTION LOT A OF LOT 4 SPLIT E X U E X U E X U EXUEXUEXU E XU E XU E X U E X U E X U EXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUE XUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEGT C XWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWSXWSXWSXWSXWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWXWXWXW S XW S X W S X W S XWS XWS XWS XWS XC XC XC XC XC XC XC XC XC XC XC XC XCXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGX G X G X G X G X G X G X G XG XG XG XG XG XG XG XG XGXGXGXGXGXG XG XG XG XG XG XG X G XGXGXG XG XG XG XG XG XG XG XG XG XG XG XG XGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXSSXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXCXCXCXCXCXCXCXC XC XC XC XC XC XC XC XC XC XC XC XC T E WS WS WS WS WS WSWSWSWSWSWSWSWSWSWSWS WS WS WS WSWSWSWSWSWSWSWSWSWSWSWSWS WS WS GGGGGG G G GGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGWS WS WS WS WS WS WS WS WS WS WS WS WS C C C C C C C C C C C C C C CGGGGGGG G G G G G G G G G G G G G G G GGGSSSS SSSSSSSSSSSSSS SS SS SS SS SS SS SS SS SS SS TTT TTTTTTTT T T T T T T T T T UEUEU E UEUEUEUEUEUEUE UE UE UE UE UE UE UE UEUE XSSXSSXSSXSSXSSXSSXSSXSS XSS XSS XSS XSS XSS XSS XSS OC< 0 00 0 98PC: 0+02.69PT: 0+05.80PC: 0+13.84PT: 0+28.00PC: 0+37.74PT: 0+68. 2 2 PC: 0+77. 3 6 PT: 0+90.51Start WalkwaySTA:0+00.00N:5221.70E:4722.94End WalkwaySTA:0+98.22N:5168.77E:4797.151002002 08 PC: 0+15.69PT : 0 + 5 0 . 6 1 P C : 0 + 7 0 . 1 6 P T : 1 + 0 0 . 9 1 P C : 1 + 2 4 . 6 1 PT: 1 + 3 9 . 0 7 End 1 0 8 M i d l a n d D r i v e w a y A l i g n m e n t STA : 2 + 0 7 . 7 5 N:51 5 1 . 1 4 E:47 4 2 . 4 7 100200PC: 0 + 4 5 . 5 4 PT: 1 + 9 6 . 2 6 PC: 2 + 1 7 . 0 2 PT: 2+80.0 2 2010020200202 97 PC: 2 0 0 + 6 4 . 1 3 PT: 2 0 2 + 1 6 . 4 1 PC: 2 0 2 + 3 7 . 1 7 End Fl o w L i n e A l i g n m e n t STA:2 0 2 + 9 7 . 3 0 N:522 9 . 3 7 E:472 2 . 7 8 1.9%12.0% 12.7%1.9%0 . 7%5.0%5.3%10100101 25 PC: 100+12.31P T : 1 0 1 + 0 7 . 7 7 Start 104 Midland Driveway AlignmentE n d 1 0 4 M i d l a n d D r i v e w a y A l i g n m e n t S T A : 1 0 1 + 2 5 . 0 0 N: 5 0 3 5 . 3 3 E: 4 7 2 0 . 8 1 Structure - (3) Structure - (4)Pipe - (2 ) Structure - (5)Pipe - (3)Structure - (6) Pipe - (4) Structure - (7)Pipe - (5)Structure - (8) Structure - (9) Pipe - ( 6 ) Structure - (10) Structure - (11)Pipe - (7) Structure - (12) Pip e - ( 8 )Pipe - (9 ) Structure - (14)Pipe - (10)Structure - (15) Structure - (16)Pipe - (11)Pipe - (12) Structure - (17) Structure - (18) Zone 2/2a 7960'-0" 7965'-0" 7970'-0" 7975'-0" 7 9 6 5 ' - 0 " 7 9 7 0 ' - 0 " 7980'-0" 7985'-0" 7975'-0" 7980'-0" 7960'-0" 7965'-0" 7970'-0"RE A R Y A R D S E T B A C K 10'- 0 "SIDE YARD SETBACK10'-0"FRO N T Y A R D S E T B A C K 25'-0"SIDE YARD SETBACK10'-0"TRA S H EN C L O S U R E MECHANICAL ENCLOSURE 7975'-0" 7973'-0" 7975'-0"PROPERTY LINEPROPERTY LINEPR O P E R T Y L I N E PROP E R T Y L I N E BIKESTORAGEMIDLAND AVE75+ +77 75++74.95 +73.95 795 7 ( 5 7 ) +79 +81.5 +84 +81.5 +80.5 +83.5+86+80+82.52 X FRONT YARD SETBACK71 Top 72? Bottom 70.75? +74.85 +71.35 +70 +67 +66.7+64.2+63.9+61.9Zone 1 Zone 4 Zone 4 Zone 4 Zone 4 Zone 8 Ex:83.36 Ex:85.21 Ex:82.52 Ex:82.59 Ex:78.53 Ex:79.22 72.85 Ex:76.80 Ex:79.13 Ex:78.23 Ex:83.71 72.85 71.46 75.15 72.65 72.15 76.71 77.5477.54 73.72 76.31 76.31 76.81 76.81 80.31 80.31 68.96 71.46 68.96 65.55 66.19 68.69 68.44 65.94 65.51 65.71 72.97 73.00 73.00 65.71 Ex:66.83 Ex:69.42 73.00 72.97 72.35 TD:72.36 BOW:72.97 73.00 BOW:72.36 71.76 76.31 76.31 76.81 76.81 74.21 73.72 79.31 79.31 79.3179.00 76.71 77.54 77.54 78.53 80.31 Ex:82.59 80.31 Ex:82.52 TOW:85.21 TOW:83.68 TOW:83.36 BOW:63.01 TOW:65.51 BOW:64.52TOW:67.02 BOW:67.59TOW:70.09 BOW:68.96TOW:71.46 BOW:71.96TOW:72.85 BOW:69.65 TOW:72.15 BOW:72.65TOW:75.15 BOW:63.84TOW:65.71 BOW:65.87TOW:67.21 BOW:68.95TOW:??? TOW:65.56BOW:65.05 TOW:70.09 BOW:67.59 TOW:71.42 BOW:68.92 TOW:72.50 BOW:70.00 TD:72.16 TOW:78.24 BOW:71.09 TOW:79.21 BOW:72.83 72.87 59.23 69.03 71.89 73.07 73.62 74.79 EntryF.F.75.00 71.82 71.57 71.53 71.23 70.59 71.10 10 0 10 20 30 Scale 1" = 10' Note: All Disturbed Areas to be revegetated with an approved seed mix and Stabilized As Necessarry Areas Gardens 509 sf+136sf+89sf= 614 Lawn 665 sf Native 2,524+6838 sf=9,392 Page 52 of 110 88245 X T X T X T X T X TXTXT XT XT XT X T X TXTXTXTXT XTXTXTXTXTXTXTXTXTXTS GE SNYDER PARK FERGUSON EXEMPTION LOT A OF LOT 4 SPLIT E X U E X U E X U EXUEXUEXU E XU E XU E X U E X U E X U EXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUE XUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEGT C XWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWSXWSXWSXWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWS XWXWXWXWXW S XW S X W S XWS XWSXCXCXCXCXCXCXCXCXC XCXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGX G X G X G X G X G X G X G XG XG XG XG XG XG XG XG XGXGXGXGXGXG XG XG XG XG XG XG X G XGXGXG XG XG XG XG XG XGXG XG XG XG XG XG XGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXSSXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXCXCXCXCXCXCXCXC XC XC XC XC XC XC XC XC XC XC XC XC T E WS WS WS WS WS WSWSWSWSWSWSWSWSWSWSWS WS WS WS WSWSWSWSWSWSWSWSWSWSWSWSWS WS WS GGGGGG G G GGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGWS WS WS WS WS WS WS WS WS WS C C C C C C C CGGGGGGG G G G G G GGGGSSSS SSSSSSSSSSSSSS SS SS SS SS SS SS SS SS SS SS TTT TTTTTTTT T T T T T T T T T UEUEU E UEUEUEUEUEUEUE UE UE UE UE UE UE UE UEUE XSSXSSXSSXSSXSSXSSXSSXSS XSS XSS XSS XSS XSS XSS XSS OC< 0 00 0 98PC: 0+02.69PT: 0+05.80PC: 0+13.84PT: 0+28.00PC: 0+37.74PT: 0+68. 2 2 PC: 0+77. 3 6 PT: 0+90.51Start WalkwaySTA:0+00.00N:5221.70E:4722.94End WalkwaySTA:0+98.22N:5168.77E:4797.151002002 08 PT : 0 + 5 0 . 6 1 P C : 0 + 7 0 . 1 6 P T : 1 + 0 0 . 9 1 P C : 1 + 2 4 . 6 1 PT: 1 + 3 9 . 0 7 STA:0+00.00End 1 0 8 M i d l a n d D r i v e w a y A l i g n m e n t STA : 2 + 0 7 . 7 5 N:51 5 1 . 1 4 E:47 4 2 . 4 7 100200PC: 0 + 4 5 . 5 4 PT: 1 + 9 6 . 2 6 PC: 2 + 1 7 . 0 2 PT: 2+ 8 0 . 0 2 2010020200202 97 PC: 2 0 0 + 6 4 . 1 3 PT: 2 0 2 + 1 6 . 4 1 PC: 2 0 2 + 3 7 . 1 7 End Fl o w L i n e A l i g n m e n t STA:2 0 2 + 9 7 . 3 0 N:522 9 . 3 7 E:472 2 . 7 8 1.9%12.0% 12.7%1.9%0. 7%5.0%5.3%00 10100101 25 PC: 100+12.31P T : 1 0 1 + 0 7 . 7 7 Start 104 Midland Driveway AlignmentSTA:100+00.00E:4607.42E n d 1 0 4 M i d l a n d D r i v e w a y A l i g n m e n t S T A : 1 0 1 + 2 5 . 0 0 N: 5 0 3 5 . 3 3 E: 4 7 2 0 . 8 1 Structure - (3) Structure - (4)Pipe - (2 ) Structure - (5)Pipe - (3)Structure - (6) Pipe - (4) Structure - (7)Pipe - (5)Structure - (8) Structure - (9) Pipe - ( 6 ) Structure - (10) Structure - (11)Pipe - (7) Structure - (12) Pip e - ( 8 )Pipe - (9 ) Structure - (14)Pipe - (10)Structure - (15) Structure - (16)Pipe - (11)Pipe - (12) Structure - (17) Structure - (18) Zone 2/2a 7960'-0" 7965'-0" 7970'-0" 7975'-0" 7 9 6 5 ' - 0 " 7 9 7 0 ' - 0 " 7980'-0" 7985'-0" 7975'-0" 7980'-0" 7960'-0" 7965'-0" 7970'-0"RE A R Y A R D S E T B A C K 10'- 0 "SIDE YARD SETBACK10'-0"FRO N T Y A R D S E T B A C K 25'-0"SIDE YARD SETBACK10'-0"TRA S H EN C L O S U R E MECHANICAL ENCLOSURE 7975'-0" 7973'-0" 7975'-0"PROPERTY LINEPROPERTY LINEPR O P E R T Y L I N E PROP E R T Y L I N E BIKESTORAGEMIDLAND AVE75+ +77 75++74.95 +73.95 795 7 ( 5 7 ) +79 +81.5 +84 +81.5 +80.5 +83.5+86+80+82.52 X FRONT YARD SETBACK71 Top 72? Bottom 70.75? +74.85 +71.35 +70 +67 +66.7+64.2+63.9+61.9Zone 1 Zone 4 Zone 4 Zone 4 Zone 4 Zone 8 Key Existing Evergreen to Remain Existing Deciduous to Remain Proposed 10-16' Evergreen (Zone 7) Proposed 2.5-4" Deciduous (Zone 6) Proposed #2 or #5 Deciduous (Zone 3) Proposed 4-6' Deciduous (Zone 3) Proposed Accent Specialty Evergreen (Zone 3) Perennials and Ground Covers (Garden Zone 2 and 2a) Path Light 10 0 10 20 30 Scale 1" = 10' Note: All Disturbed Areas to be revegetated with an approved seed mix and Stabilized As Necessarry Areas Gardens 509 sf+136sf+89sf= 614 Lawn 665 sf Native 2,524+6838 sf=9,392 Page 53 of 110 89246 A0.02 PROPOSED SITE AND EXTERIOR LIGHTING PLAN NOT FOR CONSTRUCTION 1/26/2023COUNCIL + ANDERSSON / WISE 807 Brazos St #800 Austin TX 78701 RED 1001 Grand Ave #103 Glenwood Springs CO 81601 © These documents have been specifically prepared for 108 Midland Avenue. They are not suitable for use on other projects or in other locations without the approval and participation of the architect. Reproduction prohibited without approval of the architect. 2023 Haynes Residence 108 Midland Avenue Aspen, CO 81611 SITE NOTES ① GREY BACKGROUND DENOTES EXISTING SURVEY FLOOR ELEVATIONS SECOND FLOOR - T.O. PLY. = 111'-0" (SITE = 7985'-11 1/4") FIRST FLOOR - T.O. PLY. = 100'-0" (SITE = 7974'-11 1/4") FIRST FLOOR OFFICE - T.O. PLY. = 99'-0" (SITE = 7973'-11 1/4") GARAGE - T.O. CONC. = 98'-0" (SITE = 7972'-11 1/4") CRAWL - T.O. CONC. = 93'-3 3/4" (SITE = 7967'-10 1/2") BASEMENT - T.O. PLY. = 89'-11 1/4" (SITE = 7966'-0") BASEMENT - T.O. PLY. = 88'-11 1/4" (SITE = 7965'-0") BASEMENT - T.O. PLY. = 87'-11 1/4" (SITE = 7964'-0") SET REBAR & CAP LS No. 38342 FOUND MONUMENT AS DESCRIBED SITE LEGEND EASEMENT FENCE PROPOERTY LINE EXISTING GRADE PROPOSED GRADE SETBACK LINE TREE TO BE RETAINED AS REQ'D TREE TO BE REMOVED TREE LEGEND EXISTING HOUSE CONCEPTUAL LOCATION AND FOOTPRINT OF PROPOSED HOUSE LIGHTING LEGEND 26.02 IN-GRADE LIGHT FIXTURE 26.03 RECESSED WALL LIGHT N TREE TABLE TRUNK DIAMETER IN INCHES, DRIPLINE IN FEET D = DECIDUOUS, C = CONIFER TREE #TREE TYPE DIAMETER DRIPLINE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 C D C C C C C C C C C C C C C C C C C C C C C C C C C C D D D D D D D D D D D D D D D D D D D D D D D 21 12 7 10 11 12 11 11 9 11 21 10 9 6 14 13 13 10 12 10 8 9 10 13 8 7 14 12 14 17 14 18 12 10 10 11 13 15 14 12 14 12 10 9 10 7 12 10 9 13 9 20 12 12 9 10 14 9 6 6 15 10 14 10 13 8 8 7 10 10 6 8 4 7 4 5 5 9 5 7 4 5 4 6 4 4 4 4 9 9 8 10 7 8 8 8 6 9 8 11 11 10 52 53 54 55 56 57 58 59 60 61 62 63 64 65 C C C C C C C C D D D D D D 10 13 12 9 9 12 11 14 8 14 9 11 9 14 9 14 9 11 10 11 10 14 11 9 8 7 11 810'10'25 '25'39'-5.5"1 2 3 4 5 6 7 8 1 0 1 1 2 3 2 2 2 4 2 5 2 6 2 7 2 8 2 9 3 0 3 3 3 2 3 1 9 1 2 1 3 1 4 2 0 1 8 1 9 1 5 1 7 1 6 2 1 3 7 5 0 4 9 4 8 4 7 4 6 4 5 4 4 4 3 4 2 4 1 4 0 3 9 3 8 3 6 3 5 3 4 5 2 5 4 5 6 5 5 6 5 6 3 6 4 5 1 5 3 5 8 6 0 5 9 6 2 5 7 83'-4.5" PARKING SPACE (TYP.) FIRE TRUCK TURNAROUND HOSE BIB HOSE BIB HOSE BIB HOSE BIB 2.01 26.02 26.02 26.02 26.03 26.03 26.03 26.03 26.03 32.04 32.04 32.04 32.04 26.02 26.02 26.02 26.02 26.02 26.02 26.02 26.03 26.03 32.02 32.02 32.02 32.02 32.05 35.02 32.02 32.02 32.02 AUTOCOURT OPEN NO FENCE ACCESS PROPERTY LINESIDE SETBACKREAR SETBACK FRONT SETBACK SIDE SETBACKPROPERTY L INE MIDLAND AVE CONCRETE SID E W A L K MECH ENCLOSURETRASH 7980798579807 98 0 7975797579707970 797 5 79 6 5 796 0 7 9 6 5 796 0 79 6 5 797 0 796 0 797 0 797 5 79857980 104 MIDLAND AVE 10'15'46 '-9 .5 "20'-10.5"NSCALE: 1" = 10'1Proposed Site Plan 0 5'10'20' THESE PLANS ARE CONCEPTUAL IN NATURE. INDIVIDUAL BUILDING PLANS MAY VARY BUT WILL BE EVALUATED FOR COMPLIANCE WITH DESIGN STANDARDS CONTAINED WITHIN SECTION 26.575.020 OF THE CITY OF ASPEN MUNICIPAL CODE AT THE TIME OF SUBMITTING A BUILDING PERMIT APPLICATION. Page 54 of 110 90247 PROPOSEDEXISTINGPage 55 of 110 91248 PROPOSEDEXISTINGPage 56 of 110 92249 PROPOSEDEXISTINGPage 57 of 110 93250 PROPOSEDEXISTINGPage 58 of 110 94251 PROPOSEDEXISTINGPage 59 of 110 95252 12 10 9 8 7 6 5 43 2 1 11 12 11 10 9 8 7 6 5 4 3 2 1MIDLAND AVENUEPage 60 of 110 96253 Exhibit E.1 Page 61 of 110 97254 Page 62 of 11098255 Page 63 of 110 99256 100257 Page 65 of 110 101258 September 12, 2022 Jay Engstrom Crystal River Civil LLC 1101 Village Rd UL-4C Carbondale, CO 81623 RE: 108 Midland Ave Dear Jay, The Aspen Consolidated Sanitation District currently has sufficient wastewater collection and treatment capacity to serve this project. Service is contingent upon compliance with the district’s rules, regulations, and specifications, which are on file at the District office. There are downstream constraints in the District’s collection system that will be corrected through a system of proportionate impact fees. A tap permit must be completed at our office when detailed plans become available. Fees will be estimated at that time. The total connection charges due the District must be paid prior to the issuance of a foundation and/or infrastructure permit. Existing service lines or laterals connected to the District’s main line, serving the subject property and adjacent properties must be identified, located and isolated from soil stabilization processes or other potential damage, or, properly disconnected from the ACSD main line at the point of connection according to specific ACSD requirements. Once detailed plans are made available to the district, we can comment specifically about this proposed project. Sincerely, Chip Strait Permit Technician CC Bruce Matherly, ACSD District Manager Exhibit G.1 Intent to Serve Letters Page 66 of 110 102259 Improving life with energy www.blackhillsenergy.com September, 13th 2022 Re: 108 Midland Ave Aspen, Co 81611 To whom it may concern: The above mentioned development is within the certificated service area of Black Hills Energy Black Hills Energy has existing natural gas facilities located on or near the above mentioned project. At this time it appears that these existing facilities have adequate capacity to provide natural gas service to your project, subject to the tariffs, rules and regulations on file. Any upgrading of our facilities necessary to deliver adequate service to and within the development will be undertaken by Black Hills Energy upon completion of appropriate contractual agreements and subject to necessary governmental approvals. Please contact us with any questions regarding this project, and with a timeline of when you would like to proceed with your project. Sincerely, Paul Ficklin Utility Construction Planner Black Hills Energy Glenwood Springs, Co Name Paul Ficklin Title: Utility Construction Planner paul.ficklin@blackhillscorp.com 580 Hwy 92 Delta, Co 81416 970-596-1122 Page 67 of 110 103260 Improving life with energy www.blackhillsenergy.com Page 68 of 110 104261 September 13, 2022 Jay Engstrom, P.E. Crystal River Civil LLC 1101 Village Road UL-4C Carbondale, Colorado 81623 Dear Jay: Subject: Residential Property Currently Addressed as: 108 Midland Avenue, Aspen, CO. City of Aspen Water Service In response to your recent request, this letter will serve as written verification that the City of Aspen Utilities Department currently has sufficient capacity to provide water to 108 Midland Avenue. This statement of capacity is valid for a period of 90 days from the date of this letter. Aspen makes no guarantee that it will have sufficient capacity to serve this lot if water service has not been initiated prior to the expiration of said five-year period. This letter does not represent a commitment to serve this property. To obtain water service to this property, the applicant will need to demonstrate full compliance with the requirements of the City Municipal Code and the Aspen Water Utility Standards. Due to the unknown age and condition of the service line, the developer may be required to abandon at the main water line and upsize the service line as necessary to serve this project. If you have need of additional information concerning City of Aspen water service, please do not hesitate to contact me at 970.920.5118. Sincerely, Justin Forman, P.E. Field Operations Manager City of Aspen Utilities Department justin.forman@aspen.gov Page 69 of 110 105262 3799 HIGHWAY 82∙P.O. BOX 2150 GLENWOOD SPRINGS, COLORADO 81602 (970) 945-5491∙FAX (970) 945-4081 A Touchstone Energy→ Cooperative September 12, 2022 Jay Engstrom, P.E. Crystal River Civil, LLC 970-404-1144 RE: 108 Midland Ave, Aspen The above mentioned development is within the certified service area of Holy Cross Energy. Holy Cross Energy has adequate power supply to provide electric power to the development, subject to tariffs, rules and regulations on file. Any power line enlargements, relocations, and new extensions necessary to deliver adequate power to and within the development will be undertaken by Holy Cross Energy upon completion of appropriate contractual agreements and subject to necessary governmental approvals. Please advise when you wish to proceed with the development of the electric system for this project. Sincerely, HOLY CROSS ENERGY Libby Cowling, Engineering Department lcowling@holycross.com (970) 947-5428 LC:MM Page 70 of 110 106263 108 Midland AvenueProposed Residence79607961 79627963796479657966796779687973 79727969797079717968 7972 797779787973797579767970 79727973 797579647967 79697968796679667965 79727972104 Midland AvenueExisting ResidenceMidland AvenueRight-Of-WayEast Cooper AvenueRight-Of-Way15' Open Space EasementBuilding EnvelopeProperty LineProposed 108 MidlandAvenue DrivewayProposed Regrading Of104 Midland Avenue DrivewayProposed Curb and Gutterand 5' SidewalkProposed AsphaltProposed Retaining WallsTo Minimize DisturbanceProposed Sand SetPervious WalkwayProposed Sand SetPervious PaversProposed Driveway RampGrass Paver Fire TruckTurnaroundDry Creek Landscape FeatureStormwater DrywellStormwater DrywellStormwater DrywellXCXCCCCXFOXFOFOFO<<FDFDXGXGGGGXSSXSSSSSSXUEXUEUEUEXOEXOEOEOEXTXTTTTXWXWWWWXWSXWSWSWSAbbreviations:ASTMAmerican Society of Testing and MaterialsAvg AverageBldg BuildingBMBenchmarkBMPBest Management PracticesBOW Bottom of WallCon ConcreteDemo DemolitionDia or ØDiameterDimDimensionEl or Elev ElevationExExistingFFEFinished Floor ElevationFLFlow LineFtFoot or FeetGal GallonsHoriz HorizontalHpHigh PointInvInvertLFLinear FeetLPLow PointMax MaximumMinMinimumNTS Not To ScaleOff OffsetPCPoint of Horizontal TangencyPCCPoint of Compound CurvePerf PerforatedPIPoint of Horizontal TangencyProp ProposedPVCPolyvinyl Chloride PipeQFlow RateRCPReinforced Concrete PipeROWRight-Of-WaySFSquare FeetSta StationSYSquare YardTDTrench DrainLegendExistingCommunications LineProposedEasement LineEdge of PavementEdge of GravelEdge of WaterFiber Optic LineFlow LineFoundation DrainGas LineGutter Flow Line / Break LineMajor Contour LineMinor Contour LineProperty LineSanitary Sewer LineStorm Drain LineConcrete / Sidewalk / PatioUnderground Electric LineOverhead Electric LineTelephone LineWater LineWater Service LineTOWTop of WallXRWXRWRWRWRaw Water LineDesign Notes1. The design is based on the best available information. This includes but is not limited to site conditions, features andstructures, and topographical information. Crystal River Civil is assuming no responsibility for the accuracy of site information.2.If any discrepancies or inaccurate information is found within Crystal River Civils' documents, the affected work should betemporarily put on hold. Contact CRC to verify a solution and hold all work until the necessary alterations have been made.3. No field changes are to occur without written approval of the engineer. If changes are requested and approved, Crystal RiverCivil will review the change and respond accordingly.Construction Notes1. All work completed on this project must meet standards set by the project's jurisdictions. This includes but is not limited toHOA standards, city/town standards, county standards, and/or state standards.2. The contractor is required to have a copy of current and approved construction plans. Any standards and specificationsnecessary for the work must be on site for the duration of the project as well.3. All work must be completed to horizontal and vertical information shown on the plans. If any changes have occurred, CrystalRiver Civil must verify the alterations prior to receiving approval of completion.4.Construction staking of horizontal and vertical layout is the responsibility of the Contractor. If additional documents, site visitsfor verification, or alterations are necessary, Crystal River Civil can be hired for construction administration for additionalservices.5. Property lines, monuments, benchmarks, survey control, and additional historic survey information cannot be removed andcannot be removed for construction. Disturbed survey items are the responsibility of the contractor and must be restored by astate of Colorado licensed land surveyor.6. Work and storage areas must be maintained only onsite. Project construction in Right-Of-Ways, public space, and privateproperty must be approved in writing by the necessary jurisdiction or individual.7. Limits of disturbance, tree protection, and slope protection defined within the plans must be met. Disturbances outside of theseextents may require alterations to the design and has implications that are the responsibility of the contractor. If damage shalloccur outside of these areas, the site conditions shall be restored to their original state.8.If applicable and a tree removal plan has been developed for the project, it is the responsibility of the contractor to meet theproposed conditions by the approved document. The contractor must not damage, trim, or remove trees and or bushes thatare not approved for modification by the tree removal plan. Approval for proceeding with additional tree removal must beapproved by Crystal River Civil, the landscape architect, the owner, and/or any stakeholders.9. The Contractor is responsible for removal of waste created onsite from construction. Waste material that does not meet therequirements for cannot be used for backfilling on the project and must be exported from the site.10. All materials requiring compaction must meet CDOT and/or ASTM Standards.11. If traffic control is needed for the project, it is the responsibility of the contractor to obtain and implement an approved trafficcontrol plan. Street access must be provided to the public within the Right-Of-Way - Any obstruction to general traffic flowmust be mitigated for. Pedestrian access must be always provided, and traffic entering and leaving the project site is to beobserved by the contractor.12. Dust mitigation must be provided by the contractor as necessary. Water shall be used as a dust palliative where and whenrequired. Sweeping and cleaning streets and sidewalks during the construction will be directed by the affected jurisdictions andperformed as necessary by the contractor.Utility Notes1. Utilities shown on these plans have been located and documented by the surveyor.2.Existing utilities must be verified on the site prior to construction. The contractor must protect and maintain these existingutilities throughout construction. If any damages occur to existing utility lines, it is the responsibility of the contractor tocoordinate with the utility provider replace and repair the utilities as necessary.3. The contractor must notify the utility providers a minimum of 3 days prior to any work completed. Coordination with the utilityproviders is the responsibility of the contractor.4. All utility work completed by the contractor must be installed as per the utility providers' standards and requirements.Inspections must be performed by utility providers as deemed necessary by the corresponding standards. It is theresponsibility of the contractor to organize these inspections.5.If any shallow utilities, including communication and telephone services and lines, are exposed, and temporarily altered forconstruction, the reinstallation of these utilities must conform with the utility providers standards.6. Uncovered gas lines must be temporarily contained with 18 inches backfill to minimize exposure.7. Stormwater infrastructure must pe protected by the contractor as shown in the Erosion Control Plan. During construction,additional stormwater management may be necessary during specific construction procedures and is the responsibility of thecontractor.040NSW EDrawing ScaleUnits (Feet) 1" = 20'20Vicinity MapNot to ScaleSite108 Midland AvenueAspen CO, 81611Of 11 Pages01 Council Review Drawings 12.23.2022 JKE #Description Date Drawn By 108 Midland Avenue Aspen, Colorado, 81611 1101 Village Road, Unit UL-4CCarbondale, CO 81623(970) 510 - 5312VJT Reviewed By Not For ConstructionJob #: 22.07C.01Title And NotesSheet List TableSheet NumberSheet TitleC.01Title And NotesC.02Existing ConditionsC.03Existing Conditions Steep Slope AnalysisC.04Platted Steep Slope AnalysisC.05Demolition PlanC.06Utility PlanC.07Basin Analysis And Drainage DesignC.08108 Midland Driveway Plan and ProfileC.09104 Midland Driveway Plan and ProfileC.10Grading And DrainageC.11Right-Of-Way Plan and ProfilePage 71 of 110107264 108265 0+70.00 1+30.00 D DDD<Area Within Right-Of-Way To Be Impacted57 Square FeetSteep Slopes Not To Be ImpactedSteep Slopes On 104 MidlandAvenue To Be Impacted985 Square FeetSteep Slopes On 104 MidlandAvenue Not To Be ImpactedSteep Slopes From Pond Removed FromSite Due To Pond Removal ProcessSteep Slopes On SiteTo Be Impacted343 Square FeetSteep Slopes From RetainingWall To RemainSteep Slopes Not To Be ImpactedProperty Line (Typ)Setback Line (Typ)Edge Of ExistingDrivewayEdge Of Existing DrivewayFor 104 Midland AvenueMidland Avenue79617963796579687970797279737 9 7 8 7966 798679 8 5 796079657970797579777975 7979 79707965798079827985797279607961796279637964796579667967 7968 79737972 7969 7970 797179687972797779787973797579767970 7972797379757964796779697968796679667965 7 9 7 2 7972Steep Slopes On SiteTo Be Impacted208 Square FeetSteep Slopes On SiteTo Be Impacted421 Square FeetSteep Slopes On SiteTo Be Impacted40 Square FeetOf 11 Pages01 Council Review Drawings 12.23.2022 JKE #Description Date Drawn By 108 Midland Avenue Aspen, Colorado, 81611 1101 Village Road, Unit UL-4CCarbondale, CO 81623(970) 510 - 5312VJT Reviewed By Not For ConstructionJob #: 22.07Drawing ScaleUnits (Feet) 1" = 10'1020NSWE0= 30% Steep Slope Area Not To Be Impacted= 30% Steep Slope Area Onsite To Be Impacted= 30% Steep Slope Area Offsite To Be ImpactedNote: 30% Steep Slope Areas Represented In TheseDrawings Have Been Designated By The Surveyor108 Midland AvenueProposed ResidenceC.03Existing ConditionsSteep Slope AnalysisPage 73 of 110109266 D DDSXSSXSSXSSD<Steep Slopes Not To Be ImpactedSteep Slopes On NeighboringProperty To Be Impacted632 Square FeetSteep Slopes On SiteTo Be Impacted81 Square FeetProperty Line (Typ)Setback Line (Typ)Edge Of Existing DrivewayEdge Of Existing DrivewayFor Neighboring ResidencePlatted 30% Slope AreaBook 11 Page 59Steep Slopes In Right-Of-WayTo Be Impacted82 Square FeetSteep Slopes Not To Be Impacted79617963796579687970797279737 9 7 8 7966 798679 8 5 796079657970797579777975 7979 79707965798079827985797279607961796279637964796579667967 7968 79737972 7969 7970 797179687972797779787973797579767970 7972797379757964796779697968796679667965 7 9 7 2 7972Steep Slopes On SiteTo Be Impacted2,734 Square FeetOf 11 Pages01 Council Review Drawings 12.23.2022 JKE #Description Date Drawn By 108 Midland Avenue Aspen, Colorado, 81611 1101 Village Road, Unit UL-4CCarbondale, CO 81623(970) 510 - 5312VJT Reviewed By Not For ConstructionJob #: 22.07Drawing ScaleUnits (Feet) 1" = 10'1020NSWE0= 30% Steep Slope Area Not To Be Impacted= 30% Steep Slope Area Onsite To Be Impacted= 30% Steep Slope Area Offsite To Be ImpactedNote: 30% Steep Slope Areas Represented In TheseDrawings Have Been Designated By The Surveyor108 Midland AvenueProposed ResidenceC.04Platted SteepSlope AnalysisPage 74 of 110110267 D XTXTXTXTXTXTXTXTXTXTXTXTXTXTXTXTXTXTXTXTXTXTXTXTXTXTXTXTXTEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEGTCXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWXWXWXWXWXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXWSXCXCXCXCXCXCXCXCXCXCXCXCXCXCXCXCXCXCXCXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGESXSSXSSXSSTCEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXCXCXCXCXCXCXCXCXCXCXCXCXCXCXCXCXCXCXCXCTEDXSSXSSXSSXSSXSSXSSXSSXSSXSSXSSXSSXSSXSSXSSXSS<79617963796579687970797279737 9 7 8 7966 798679 8 5 796079657970797579777975 7979 797079657980798279857972Abandon Existing Water Service Tap For 108 Midland AvenueVerify Abandonment Of Old 104 Midland Avenue ServiceAs Per City of Aspen Water District Standards.Contact City Of Aspen Prior To AbandonmentAbandon Existing Water Service Tap For 104 Midland AvenueAs Per City of Aspen Water Department Standards.Contact City Of Aspen Prior to AbandonmentCommunications Service for 104 MidlandTo Be Lowered During DrivewayReconstruction To Meet UtilityProvider Requirements102 Linear FeetBlack Hills Energy Natural Gas Service for 104 MidlandTo Be Realigned And Lowered During DrivewayReconstruction To Meet UtilityProvider Requirements75 Linear FeetBlack Hills Energy Natural Gas Service for 108 MidlandTo Be Realigned And Lowered During DrivewayReconstruction To Meet UtilityProvider Requirements100 Linear FeetRemove or Abandon Existing WaterService For 104 Midland Avenue85 Linear FeetRemove or Abandon Existing WaterService For 104 Midland Avenue250 Linear FeetRemove Or Abandon TelephoneService for 108 Midland88 Linear FeetRemove Or Abandon ElectricalService for 108 Midland94 Linear FeetRemove CommunicationsService for 108 Midland105 Linear FeetRemove Sewer Servicefor 108 Midland88 Linear FeetRepair And Service Sewer ManholeAs Necessary For New Service Tie-InAs Per ACSD StandardsMill 2' of Existing Asphalt Along Sawcut546 Square FeetSawcut AsphaltLayout Shown on Right-Of-WayPlan and Profile Sheet270 Linear FeetRemove Existing Asphalt2,026 Square FeetDemolish Existing Sidewalk and Curb and Gutter165 Linear FeetRemove Existing Concrete Driveway5,710 Square FeetGrub and Prep Area For Improvements2,160 Square FeetSawcut AsphaltLayout Shown on Right-Of-WayPlan and Profile Sheet24 Linear FeetMill 2' of Existing Asphalt Along Sawcut24 Square FeetRemove Existing Asphalt36 Square FeetGrub and Prep Area For Improvements3,801 Square FeetDemolish ImprovementsAround Existing Residence575 Square FeetDemolish Existing ResidenceNote: For Tree Removal Information, See Tree Mitigation PlanRemove Abandoned Utilities As NecessaryFor Installation Of Proposed InfrastructureOf 11 Pages01 Council Review Drawings 12.23.2022 JKE #Description Date Drawn By 108 Midland Avenue Aspen, Colorado, 81611 1101 Village Road, Unit UL-4CCarbondale, CO 81623(970) 510 - 5312VJT Reviewed By Not For ConstructionJob #: 22.07Drawing ScaleUnits (Feet) 1" = 10'1020NSWE0C.05Demolition PlanPage 75 of 110111268 D DDXTXTXTXTXTXTXTXTXTXTXTXTXTXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEGXWXWXWXWXWXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGESXSSXSSXSSTCEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOETEDWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSCCCCCCCCCCCCCCCCCCCCCGGGGGGGGGGGGGGGGGGGGGGGGGSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSTTTTTTTTTTTTTTTTTTTTUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEOC<79617963796579687970797279737 9 7 8 7966 798679 8 5 796079657970797579777975 7979 79707965798079827985797279607961796279637964 7965 7966 7967 7968 79737972 7969 7970 797179687972797779787973797579767970 7972797379757964796779697968796679667965 7 9 7 2 7972Install 2" Water Service Tap As PerCity Of Aspen Water Department StandardsMaintain 18" of Separation Between All Fittings2-Way Sewer CleanoutWithin 5' of Structure45° Bends103± Linear Feet of 4" SDR-26Gravity Sanitary Sewer Service LineMaintain Min. 5 Feet Of Cover Over Pipe100± Linear Feet Electric ServiceWithin 2" Conduit As Per CityOf Aspen Electric Standards97± Linear Feet Telecom ServiceWithin 2" Conduit As PerUtility Provider Standards208± Linear Feet GasService For 108 MidlandLine Material and SizePer Black Hills EnergyRequirements128± Linear Feet GasService Realignment AndExtension For 104 MidlandLine Material and SizePer Black Hills EnergyRequirementsTie Into Existing Sewer ManholeGrout and Seal Pipe Into ManholeAs Per ACSD Standards188± Linear Feet 2" Type K CopperWater Service From Curb Stop ToWater Meter For 108 Midland97± Linear Feet Type K CopperWater Service From Curb Stop ToWater Meter For 104 MidlandMatch Size of ExistingWater Service105± Linear Feet Telecom ServiceWithin 2" Conduit As PerUtility Provider StandardsCommunications PedestalInstall Water Service Tap As PerCity Of Aspen Water Department StandardsSize Service To Match Existing TapMaintain 18" SeparationBetween All Fittings12± Linear Feet Type K CopperWater Service From Tap ToCurb Stop For 104 MidlandMatch Size of ExistingWater ServiceInstall Curb Stops For104 And 108 Midland AvenueTie Into Existing Service12± Linear Feet 2" Type K CopperWater Service From Tap ToCurb Stop For 104 MidlandCurb Stop Every 100Feet Of ServiceGas MeterBlack Hills Energy GasService TapsTelephone PedestalHoly Cross Electric TransformerVerify Capacity Prior To ConstructionVerify and MaintainSeparation RequirementsFor All Utility CrossingsOf 11 Pages01 Council Review Drawings 12.23.2022 JKE #Description Date Drawn By 108 Midland Avenue Aspen, Colorado, 81611 1101 Village Road, Unit UL-4CCarbondale, CO 81623(970) 510 - 5312VJT Reviewed By Not For ConstructionJob #: 22.07Drawing ScaleUnits (Feet) 1" = 10'1020NSWE0C.06Utility PlanPage 76 of 110112269 D DDXTXTXTXTXTXTXTXTXTXTXTXTXTEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXWXWXWXWXWDSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSTTTTTTTTTTTTTTTTTTUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEXSSXSSXSSXSSXSSXSSXSSXSSXSSXSSXSSXSSOC<79617963796579687970797279737 9 7 8 7966 798679 8 5 796079657970797579777975 7979 79707965798079827985797279607961796279637964796579667967 7968 79737972 7969 7970 797179687972797779787973797579767970 7972797379757964796779697968796679667965 7 9 7 2 7972Additional Stormwater Design For 108 MidlandAvenue To Be Provided for Permit Set SubmittalExisting Drywell Collects StormwaterIn Autocourt For 104 Midland Avenue35,945 Sq Ft56.5% Imp.Trench Drain With Catch BasinTies Directly To Drywell25,736 Sq Ft78.4% Imp.12,669 Sq Ft68.2% Imp.DownspoutsDownspoutDownspoutDownspoutDownspoutTrench DrainTrench DrainDrywell 14' Diameter 12' Deep10' Deep of Capacity193 Cubic Feet of DetentionSized For Full Detention ofa 100-Year 1-Hour Storm EventDrywell 26' Diameter 17' Deep15' Deep of Capacity488 Cubic Feet of DetentionSized For Full Detention ofa 100-Year 1-Hour Storm EventDriveway Drywell6' Diameter 12' Deep10' Deep of Capacity350 Cubic Feet of DetentionSized For Full Detention ofa 100-Year 1-Hour Storm EventInletOf 11 Pages01 Council Review Drawings 12.23.2022 JKE #Description Date Drawn By 108 Midland Avenue Aspen, Colorado, 81611 1101 Village Road, Unit UL-4CCarbondale, CO 81623(970) 510 - 5312VJT Reviewed By Not For ConstructionJob #: 22.07Drawing ScaleUnits (Feet) 1" = 10'1020NSWE0C.07Basin Analysis And DrainageDesignPage 77 of 110113270 XWXWXWXWXWDC<0+70.00 1+30.00 D D108 MidlandProposed ResidenceStart Driveway60° Angle Off Curb and GutterSta:0+09.54Off:0.00'0 00 1 00 2 00 2 08PC: 0+15.69PC: 1+24.61PC: 0+70.16PT: 0+50.61PT: 1+39.07PT: 1+00.91Start 108 Midland Driveway AlignmentSTA:0+00.00N:5012.28E:4605.02End 108 Midland Driveway AlignmentSTA:2+07.75N:5151.14E:4742.47Curb And Gutter Flow LineSta:0+05.01Off:8.00'RElev:7960.03Edge Of PavementSta:0+09.77Off:10.75'RElev:7960.15Curb And Gutter Flow LineSta:0+15.89Off:11.12'LElev:7959.12Edge Of PavementSta:0+21.96Off:8.00'LElev:7959.23Start Driveway Seperation TransitionSta:0+43.05Off:8.06'RElev:7962.0330" Boulder WallSta:0+55.04Off:8.00'RElev:7963.01Start 30" Boulder WallSta:0+75.49Off:7.99'LElev:7965.05End 30" Boulder WallStart Concrete WallSta:1+48.44Off:7.50'LElev:7970.35796179637965796879707972797379 7 8 7966 79867985 7960796579707975797779757979797079657980798279857972Tiered 30" Boulder WallSta:1+18.09Off:12.50'RElev:7971.96End Tiered 30" Boulder WallStart Concrete WallSta:1+50.74Off:36.00'RElev:7971.76Concrete WallSta:1+50.74Off:58.34'RElev:7972.36Concrete WallSta:1+84.06Off:62.38'RElev:7972.97Edge of PavementTrench DrainSta:1+67.23Off:32.72'RElev:7972.16L4L1L2L3C1C3C216.0'Edge of PavementSta:2+02.75Off:7.50'LElev:7972.8330" Boulder WallSta:1+33.27Off:9.22'RElev:7969.6530" Boulder WallSta:1+24.61Off:8.00'RElev:7969.26R30'R30'Edge of PavementSta:1+96.75Off:8.50'RElev:7972.63Edge of PavementSta:2+02.75Off:8.50'RElev:7972.8730" Boulder WallSta:0+51.74Off:16.76'RElev:7963.86Edge Of PavementSta:0+19.33Off:12.31'RElev:7960.47Edge Of PavementSta:0+38.98Off:21.22'RElev:7962.77For Driveway RampSee City Of Aspen DetailOn Sheet C.01610.0%4.6%3.9%5.0%2.0%12.0%See 104 Midland Driveway PlanAnd Profile For Additional InformationEnd Tiered 30"Boulder WallSta:1+46.25Off:36.00'RElev:7974.213'3'6'9'Series of 30" CortenRetaining WallsFire Truck Turning RadiusFrom East CooperOnto DrivewayGrass PaverFire TruckTurnaround108 MidlandConcreteDriveway104 MidlandConcreteDriveway3'For Right-Of-Way ImprovementsSee Sheet C.013-C.015ProposedAsphaltProposed S idewa lkWi th Curb and Gu t ter Trench DrainSta:1+63.92Off:59.94'RElev:7972.360.0%2.6%Ex:83.36Ex:85.21Ex:82.52Ex:82.59Ex:78.53Ex:79.2272.85Ex:76.80Ex:79.13Ex:78.23Ex:83.71End DrivewaySta:2+02.753.0:13.0:1 72.8571.4675.1572.6572.1576.7177.5477.5473.7276.3176.3176.8176.8180.3180.3168.9671.4668.9665.5566.1968.6968.4465.9465.5165.7172.9773.0073.00Trench DrainSta:1+39.87Off:13.42'RElev:7970.21Trench DrainSta:1+39.87Off:8.00'LElev:7969.96Trench DrainSta:0+42.64Off:7.90'RElev:7962.00Trench DrainSta:0+42.35Off:8.00'LElev:7961.49Trench DrainSta:0+37.26Off:19.76'RElev:7962.407960796 1 7962 7963 7964 7965 7966 7967 7968 797379727969 79707971796879727977797879737 9 7 5 797679707972797379757 9 6 4 7 9 6 7 7 9 6 9 79 6 8 7 9 6 6 79 6 6 7 9 6 5 797 2 7972Midland AvenueRight-Of-WayEast Cooper AvenueRight-Of-WayDrywellSta:0+45.04Off:8.78'RNote: Drainage Stormwater System for 108Midland Avenue to be completed for Permit Set7 9 7 3 7974Edge of PavementTrench DrainSta:1+72.87Off:20.34'RElev:7971.82Edge of PavementTrench DrainSta:1+75.09Off:1.13'RElev:7971.57Edge of PavementTrench DrainSta:1+67.72Off:7.50'LElev:7971.23Edge of PavementTrench DrainSta:1+53.64Off:5.35'LElev:7970.59108 Midland Driveway Alignment ProfileHorizontal Scale: 1"=10'Vertical Scale: 1"=10'795579607970798079557960797079800+20EG 7960.6 FG 7959.610+40EG 7962.9 FG 7961.500+60EG 7966.1 FG 7963.500+80EG 7969.8 FG 7965.50 1+00EG 7972.5 FG 7967.50 1+20EG 7975.3 FG 7969.05 1+40EG 7976.8 FG 7969.96 1+60EG 7978.1 FG 7970.88 1+80EG 7978.3 FG 7971.79 2+00EG 7979.4 FG 7972.71 -0.63%10.00%4.58%Start Driveway Sta = 0+09.54Elev = 7959.570GRADE BREAK STA = 2+02.75ELEV = 7972.834LOW PT STA: 0+16.48LOW PT ELEV: 7959.53PVI STA:0+20.00PVI ELEV:7959.50K:0.75LVC:8.00BVCS: 0+16.00BVCE: 7959.53EVCS: 0+24.00EVCE: 7959.90HIGH PT STA: 1+16.99HIGH PT ELEV: 7968.91PVI STA:1+11.57PVI ELEV:7968.66K:2.00LVC:10.85BVCS: 1+06.15BVCE: 7968.12EVCS: 1+16.99EVCE: 7968.91Edge of Open Space Easement108 MidlandProperty LineSetback LineExisting Driveway GradeProposed Driveway GradeSta:0+15.86Elev:7959.53104 Midland Property Line0+70.0079557960796579707975-20 -15 -10 -5 0 5 10 15 20Edge of DriveOff=-8.00El=7964.50Edge of DriveOff=8.00El=7964.50Top of WallOff=9.51El=7967.01Existing GradeProposed Grade1+30.00796079657970797579807985-20 -15 -10 -5 0 5 10 15 20 25 30Existing GradeProposed GradeTop Of WallOff=-9.50El=7972.00Edge of RoadOff=8.47El=7969.50Top Of WallOff=9.98El=7972.01Top Of WallOff=14.53El=7975.03Edge of RoadOff=-8.00El=7969.50Bottom Of WallOff=12.99El=7972.52Line TableLineL1L2L3L4BearingS87°45'51"EN39°35'14"EN48°23'51"EN26°35'14"ELength15.69'19.54'23.70'68.67'Start Point (N,E)5012.28,4605.025025.43,4651.475062.59,4685.275089.73,4711.74End Point (N,E)5011.67,4620.705040.49,4663.935078.33,4702.995151.14,4742.47Curve TableCurveC1C2C3Radius38.00'200.00'38.00'Length34.92'30.75'14.47'Tangent18.80'15.41'7.32'Chord33.70'30.72'14.38'BearingN65°54'41"EN43°59'32"EN37°29'32"EDelta52° 38' 56"8° 48' 37"21° 48' 37"Of 11 Pages01 Council Review Drawings 12.23.2022 JKE #Description Date Drawn By 108 Midland Avenue Aspen, Colorado, 81611 1101 Village Road, Unit UL-4CCarbondale, CO 81623(970) 510 - 5312VJT Reviewed By Not For ConstructionJob #: 22.07Drawing ScaleUnits (Feet) 1" = 10'1020NSWE0C.08108 Midland DrivewayPlan and ProfilePage 78 of 110114271 DD 100 00 101 00 101 25 PC: 100+12.31PC: 100+65.59PT: 100+35.08PT: 101+07.77Start 104 Midland Driveway AlignmentSTA:100+00.00N:5018.43E:4607.42End 104 Midland Driveway AlignmentSTA:101+25.00N:5035.33E:4720.817961796379657968797079727966 7972108 MidlandConcreteDriveway104 MidlandConcreteDrivewayProposedAsphaltProposed S idewa lkWi th Curb and Gu t ter796079 6 1 7962 7963 7964 7965 7966 7967 7968 7969 79707968797279737 9 7 5 79767970797279737 9 6 4 79 6 7 7 9 6 9 79 6 8 7 9 6 6 79 6 6 7 9 6 5 7972Edge Of PavementSta:100+14.39Off:11.11'RElev:7960.15Start DrivewaySta:100+09.50Off:0.00'Elev:7959.48Edge Of PavementSta:100+22.78Off:8.65'RElev:7960.47Edge Of PavementSta:100+49.59Off:7.04'RElev:7962.77Edge Of PavementSta:100+49.95Off:8.89'RElev:7962.81Trench DrainSta:100+46.50Off:7.05'RElev:7962.40Trench DrainSta:100+46.50Off:6.87'LElev:7962.00Edge Of Driveway TransitionSta:100+47.00Off:7.03'LElev:7962.03Edge Of PavementBottom Of WallSta:100+60.99Off:8.18'LElev:7963.86Edge Of PavementSta:100+74.37Off:7.97'RElev:7965.88Edge Of PavementSta:100+90.07Off:11.70'RElev:7968.13Edge Of PavementSta:100+99.41Off:12.15'RElev:7969.20Edge Of PavementSta:100+14.39Off:11.11'RElev:7960.15Edge Of PavementSta:100+14.39Off:11.11'RElev:7960.15Tie Into Existing ConcreteSta:101+14.93Off:13.54'LElev:7968.95Tie Into Existing ConcreteSta:101+21.17Off:10.25'RElev:7969.03Existing DrywellSta:101+23.55Off:3.99'LElev:7969.36L5 L6L7C4C5Edge Of PavementSta:100+16.08Off:10.85'LElev:7959.23Edge Of PavementSta:100+74.85Off:9.39'LElev:7965.53R45'Bottom Of WallSta:100+56.72Off:16.50'LElev:7963.0165.71Ex:66.83Ex:69.4216.5'Replace Existing Rock WallsTo Transition To Existing GradeMax 30" Boulder Wall12.0%1.5%2.0% 1. 0% 3.0%Property Line (Typ)Property Line (Typ)15' Open Space EasementMidland AvenueRight-Of-WayEast Cooper AvenueRight-Of-WayDrywellSta:100+49.34Off:8.04'L104 Midland Driveway Alignment ProfileHorizontal Scale: 1"=10'Vertical Scale: 1"=10'795579607970795579607970100+20EG 7960.8 FG 7959.79 100+40EG 7963.3 FG 7961.70 100+60EG 7965.4 FG 7964.10 100+80EG 7967.7 FG 7966.50 101+00EG FG 7968.74 101+20EG FG -2.00%2.00%4.00%12.00%PVI STA: 100+26.14PVI ELEV: 7960.04K: 1.50LVC: 12.00BVCS: 100+20.14 BVCE: 7959.80 EVCS: 100+32.14 EVCE: 7960.76 PVI STA: 101+03.47PVI ELEV: 7969.32K: 1.50LVC: 21.00BVCS: 100+92.98 BVCE: 7968.06 EVCS: 101+13.97 EVCE: 7969.11HIGH PT. STA: 101+10.97HIGH PT ELEV: 7969.14START DRIVEWAY STA = 100+09.50ELEV = 7959.483TIE INTO EXISTING DRIVEWAYSTA = 101+18.48ELEV = 7969.016104 Midland Property LineLine TableLineL5L6L7BearingS58°14'13"EN87°26'17"EN47°09'04"ELength12.31'30.51'17.23'Start Point (N,E)5018.43,4607.425006.30,4639.595023.61,4708.18End Point (N,E)5011.95,4617.895007.66,4670.065035.33,4720.81Curve TableCurveC4C5Radius38.00'60.00'Length22.77'42.19'Tangent11.74'22.01'Chord22.43'41.32'BearingS75°23'58"EN67°17'40"EDelta34° 19' 30"40° 17' 13"Of 11 Pages01 Council Review Drawings 12.23.2022 JKE #Description Date Drawn By 108 Midland Avenue Aspen, Colorado, 81611 1101 Village Road, Unit UL-4CCarbondale, CO 81623(970) 510 - 5312VJT Reviewed By Not For ConstructionJob #: 22.07Drawing ScaleUnits (Feet) 1" = 10'1020NSWE0C.09104 Midland DrivewayPlan and ProfilePage 79 of 110115272 XTXTXTXTXTXTXTXTXTXTXTXTXTXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEGXWSXWSXWSXWXWXWXWXWXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGESXSSXSSXSSTCEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOETEDWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSCCCCCCCCCCCCCCCCCCCCCGGGGGGGGGGGGGGGGGGGGGGGGGSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSTTTTTTTTTTTTTTTTTTTTUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEOC<0+70.00 1+30.00 D DD108 MidlandProposed Residence10.0%3.0:1 3.0%10.0%4.6%5.9%79617963796579687970797279737 9 7 8 7966 798679 8 5 796079657970797579777975 7979 797079657980798279857972Grass PaverFire TruckTurnaround108 MidlandConcreteDriveway104 MidlandConcreteDrivewayProposedAsphaltProposed SidewalkWith Curb and Gutter79607961796279637964 7965 7966 7967 7968 79737972 7969 7970 797179687972797779787973797579767970 7972797379757964796779697968796679667965 7 9 7 2 7972Midland AvenueRight-Of-WayEast Cooper AvenueRight-Of-Way73.0072.9772.35TD:72.36BOW:72.9773.003.1%3.9%3.4%5.0% 2.6%BOW:72.3671.7676.3176.3176.8176.8174.2173.7279.3179.3179.3179.0076.7177.5477.5478.5380.31Ex:82.5980.31Ex:82.52TOW:85.21TOW:83.68TOW:83.36Corten Retaining WallsMax. 30" Tall With 3' StepsVarying Boulder AndCorten Retaining WallsMax. 30" Tall With 3' StepsBOW:63.01TOW:65.51BOW:64.52TOW:67.02BOW:67.59TOW:70.09BOW:68.96TOW:71.46BOW:71.96TOW:72.85BOW:69.65TOW:72.15BOW:72.65TOW:75.15BOW:63.84TOW:65.71BOW:65.87TOW:67.21BOW:68.95TOW:???BOW:65.56TOW:65.05BOW:70.09TOW:67.59BOW:71.42TOW:68.92BOW:72.50TOW:70.00TD:72.16BOW:78.24TOW:71.09BOW:79.21TOW:72.8372.8760.1559.230.7%69.0368.132.0%Note: Drainage Stormwater System for 108Midland Avenue to be completed for Permit Set71.8973.0773.6274.79EntryF.F.75.002.0%2.8%1.8%7973797 42 - 7" Steps2 - 7" StepsWater FeaturePerviousPavers71.8271.5771.5371.2370.5971.104.6%Stormwater DrywellStormwater DrywellPervious Paver Access Walkwaywith Bike RampUtility AreaDry Creek Landscape FeatureOf 11 Pages01 Council Review Drawings 12.23.2022 JKE #Description Date Drawn By 108 Midland Avenue Aspen, Colorado, 81611 1101 Village Road, Unit UL-4CCarbondale, CO 81623(970) 510 - 5312VJT Reviewed By Not For ConstructionJob #: 22.07Drawing ScaleUnits (Feet) 1" = 10'1020NSWE0C.10Grading And DrainagePage 80 of 110116273 XTXTXTXTXTXTXTXTXTXTXTXTXTXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEXUEGXWSXWSXWSXWXWXWXWXWXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGXGESXSSXSSXSSTCEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOEXOETEWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGWSWSWSWSWSWSWSWSWSWSWSWSCCCCCCCCCGGGGGGGGGGGGGGGSSSSSSSSSSSSSSSSSSSSSSSSSSSSTTTTTTTTTTTTTTUEUEUEUEUEUEUEUEUEUEUEUEUE<D 200+40.00200+50.00200+60.00200+70.00200+80.00200+90.00201+00.00 201+10.00 201+20.00 201+30.00 201+40.00 201+50.00 201+60.00 201+70.00 201+80.00 201+90.00 202+00.00 202+10.00 202+20.00 202+30.00 202+40.00 202+50.00 202+60.00 202+70.00 202+80.0 0 202+90.0 010.0%10.0%5.0%4.6%79617963796579687970797279737 9 7 8 7966 796079657970797579777975 7979 7970796579607961796279637964 7965 7966 7967 7968 7972 7969 7970 797179687970 79727973797579647966 200 00 201 00 202 00 202 97 PC: 200+64.13PC: 202+37.17PT: 202+16.41Start Flow Line AlignmentSTA:200+00.00N:4966.00E:4586.12End Flow Line AlignmentSTA:202+97.30N:5229.37E:4722.78L8L9C6C7Proposed Asphalt with 2' MillSta:200+01.57Off:28.13'RProposed Asphalt with 2' MillSta:200+11.56Off:28.56'RProposed Asphalt with 2' MillSta:200+01.14Off:38.12'RProposed Asphalt with 2' MillSta:200+11.13Off:38.55'RReplace Asphalt FromWater Line WorkProposed Asphalt with 2' MillSta:200+36.10Off:12.01'LProposed Asphalt with 2' MillSta:200+36.10Off:2.00'LStart Curb and Gutter0% Slope Into Flow LineSta:200+38.10Off:0.00'LElev:7960.375' Attached SidewalkSta:200+38.10Off:0.50'RElev:7960.605' Attached SidewalkSta:200+38.10Off:5.50'RElev:7960.708.3%Driveway RampSta:200+44.81Off:0.00'RElev:7960.03Driveway RampSta:200+44.75Off:5.47'RElev:7960.15Driveway RampSta:200+66.78Off:0.00'RElev:7959.12Driveway RampSta:200+66.76Off:5.50'RElev:7959.23Curb and GutterStart Transition From0% Slope Into Flow LineTo 8.33% Slope Into Flow LineSta:200+72.78Off:0.00'RElev:7959.085' Attached SidewalkSta:200+72.77Off:0.50'RElev:7959.565' Attached SidewalkSta:200+72.74Off:5.50'RElev:7959.66Start 18" Boulder WallSta:200+71.41Off:5.50'RElev:7959.575.0%5.0%1.0%1.0%Proposed Driveway RampSee Detail2.0%7.2%2.0%2.0%Curb and GutterEnd Transition From0% Slope Into Flow LineTo 8.33% Slope Into Flow LineSta:200+90.00Off:0.05'LElev:7958.89End 18" Boulder WallSta:202+75.50Off:5.50'REnd Curb and GutterSta:202+92.59Off:0.00'Elev:7956.865' Attached SidewalkSta:202+92.59Off:0.50'RElev:7957.365' Attached SidewalkSta:202+92.59Off:5.50'RElev:7957.463.8%2.3%1.1%1.6%1.7%0.4%0.7%0.7%2.7%3.5%1.3%0.9%2.4% 1.9% 1.1% 0.9% 2.2% 4.5% 6.5% 2.6% 1.7% 0.6% 0.7%0.1%3.2%3.8%1.0%1.0%1.0%1.0%2.0% 2.0% 2.0% 2.0% 2.0%4.6%Note: Sections To Be Completed for Permit Set.Flow Line Alignment ProfileHorizontal Scale: 1"=10'Vertical Scale: 1"=10'7950796079507960200+20EG FG200+40EG 7960.2 FG 7960.25200+60EG 7959.2 FG 7959.18200+80EG 7959.0 FG 7959.04201+00EG 7959.4 FG 7959.42 201+20EG 7958.3 FG 7958.28 201+40EG 7958.6 FG 7958.60 201+60EG 7958.1 FG 7958.07 201+80EG 7958.1 FG 7958.13 202+00EG 7957.9 FG 7957.92 202+20EG 7957.8 FG 7957.78 202+40EG 7957.6 FG 7957.59 202+60EG 7957.3 FG 7957.34 202+80EG 7957.0 FG 7956.97 -5.00%-1.00%GRADE BREAK STA = 200+38.10ELEV = 7960.367 GRADE BREAK STA = 202+92.59 ELEV = 7956.860 Of 11 Pages01 Council Review Drawings 12.23.2022 JKE #Description Date Drawn By 108 Midland Avenue Aspen, Colorado, 81611 1101 Village Road, Unit UL-4CCarbondale, CO 81623(970) 510 - 5312VJT Reviewed By Not For ConstructionJob #: 22.07Drawing ScaleUnits (Feet) 1" = 10'1020NSWE0C.11Right-Of-Way Plan and ProfilePage 81 of 110117274 Crystal River Civil LLC 970.510.5312 Page 1 of 5 108 Midland Avenue Engineering Memo January 23, 2023 Existing Conditions The property addressed as 108 Midland Avenue in Aspen, CO 81611 is defined as Lot 1 of the Ferguson Exemption Subdivision, or parcel #273718126110. The parcel is located to the east of downtown Aspen. This property is situated with Midland Avenue to the west and residential homes on the southern and eastern property border. To the north of the property is an open space parcel that is owned by the City of Aspen. Shown above is an image of the Pitkin County GIS Map displaying the location of 108 Midland Avenue The existing conditions of the property under evaluation include a single-family residence with a asphalt paved driveway, patio spaces, and landscaping. The existing home sits in the center of the property, with the driveway access approaching the house from the southern property line. The site generally slopes from the east to the west, with steep grades along the western property line. The existing vegetation includes pines, aspen trees, and brush surrounding the site. All the described conditions can be seen on the Existing Conditions sheet (C.02) of the submitted civil drawings. The following topics discuss in further depth the access, utilities, stormwater, and the natural and manmade hazards on the site: Exhibit G.3 Page 82 of 110 118275 Crystal River Civil LLC 970.510.5312 Page 2 of 5 Access: The driveway curb cut for the site is shared with the neighboring residence to the south, 104 Midland. The driveway starts on the southwest corner of the neighbor’s property and immediately splits into each individual drive, with the 108 Midland driveway extending to the northeast. It continues onto the property, levels out in grade for a parking area, and ties into the existing garage within the residence. The finish floor of the garage is over 20 feet higher than the Right-Of-Way below, therefore the 200-foot-long driveway has steep grades that exceed 16 percent. The narrowest part of the access is around twelve feet wide, and existing trees and foliage have grown into the driveway limiting clearances even further. Crystal River Civil met with the Aspen Fire Protection District onsite to discuss the access onto the property, and the existing conditions do not meet their requirements. Utilities: Water: The water service for the residence extends from the water main located under East Cooper Avenue to the southwest of the site. The water service is common trenched with the service for 104 Midland from the water main under the road, curb and gutter, sidewalk, and landscaping. Once the services reach the shared access, they split and the 104 Midland service continues to the east to tie into the neighboring residence. The 108 Midland water service continues up the access and ties into the house near the garage. The service material and sizing are unknown. Sewer: The sewer service extends off the north side of the house. It continues to the northwest and ties into the existing Aspen Consolidated Sanitation District sanitary sewer system via gravity from the residence. Electric and communications: An electric transformer and communications pedestals are located just northwest of the property. Services to the residence extend onto the property and tie into the north side of the structure. Gas: A gas service extends from the right of way by the driveway curb cut and continues up the drive and around the west side of the structure. The gas meter is located on the west side of the garage. All the described conditions can be seen on the Existing Conditions sheet (C.02) of the submitted civil drawings. Stormwater: The residence does not appear to have any existing stormwater management in place. There is a trench drain in the driveway that ties into a drywell by the access entrance. This is shared with a trench drain on the neighboring driveway as well. Upon inspection, appears the trench drains have not been maintained and the existing system is not working as intended. Additionally, sizing of this system is unknown. Hazards: The site is not impacted by any floodplains, mudflows, debris flow areas, avalanche areas, or any known mining activity or deposits. A steep slope separates the Midland Avenue from the residence and the corresponding access drive. The slope varies along hillside, with areas exceeding 1.5:1, or 65 percent. This grade appears to be manmade consisting of fill material when the site was developed, as well as potentially a cut for the construction of Midland Avenue, its curb and gutter and its sidewalk. Given the time period since construction of this slope, a reasonable amount of foliage and native grasses Page 83 of 110 119276 Crystal River Civil LLC 970.510.5312 Page 3 of 5 currently cover the hillside. The hillside is relatively short with no flow lines or points of concentration, and there are no signs of any movement or erosion. The plat for the subdivision references these steep slopes and includes verbiage that no development is to occur within these areas. It does refence the correct area for this hillside, but the platted area does extend into parts of the property that do not pertain to the steep slopes. Proposed Conditions The proposed conditions at 108 Midland Avenue includes the development of a new single-family residence. The proposed structure is relatively in the same location of the existing home, however it will not share any existing foundation or footprint. An attached garage will be located on the southeast corner of the building, and an office space will extend towards the northeast corner. New utility services will be constructed, as well as improvements to the vehicular and emergency access, stormwater infrastructure, and general site plan improvements. Additionally, there are proposed upgrades within the Midland Avenue, including improving and reconstructing the curb and gutter, sidewalk, and retaining wall along the sidewalk along the front of 104 and 108 Midland Avenue. Below are summaries of improvements to each topic. Access: The overall location of the access will remain the same, but major alterations are proposed to bring the access up to code and meet the requirements of Aspen Fire Protection District (AFPD). Discussions with AFPD occurred onsite to ensure he project is meeting all the needs for emergency access. This impacts the neighbor’s driveway as well, which requires regrading of their driveway in order to bring everything into compliance. The access curb cut is proposed in the same location of the existing drive. The curb ramp has been designed to meet the City of Aspen Engineering Standards, in addition to transitions to the existing sidewalk to the south. The drive has been lowered to meet the slope requirements of the city, which impacts the entire length of the 108 Midland driveway and a large portion of the 104 Midland driveway. Turning radii and widths for a fire truck have been analyzed to verify accessibility. The neighbor’s driveway will be regraded to meet the twelve percent slope and will utilize the existing footprint of surfacing. Once the shared driveway splits, the access to 108 Midland extends further west than the existing drive. This allows for planting buffers to remain between the residences, as well as minimizing impacts to the neighboring property. The driveway maintains a 16-foot width and does not exceed twelve percent centerline slope. To achieve this, a series of retaining walls are proposed to minimize impacts on both sides. As the driveway crosses the property line of 108 Midland, the slopes are reduced to six percent, as required for a fire truck turnaround. This turnaround utilizes a large portion of the general vehicle access, but incudes an additional drivable grass paver surface. The driveway continues off the turnaround to the northeast, allowing for additional parking and access to the garage. Page 84 of 110 120277 Crystal River Civil LLC 970.510.5312 Page 4 of 5 Utilities: Water: Given the extensive grading of the site access, improvements will be made to both the neighbors water service and the 108 Midland Avenue service. The services within East Cooper Avenue will be abandoned as per the Aspen Water Department requirements. New services will tap into the water main under Midland Avenue, just west of the shared access curb cut. The neighbor’s service will be replaced and tied into the residence at the existing location. The service for 108 Midland will continue up the driveway and tie into the south side of the building. Sewer: The proposed sanitary sewer service will be similar in location to the existing service, but will be replaced. The service will release from the residence on the north side of the structure and extend downhill to the existing sanitary main. This will be designed to meet all requirements of ACSD. Electric and Communications: The project is currently proposing to utilize the existing transformer and communications pedestals. If any improvements are needed for the existing systems, they will be upgraded as necessary. The services will extend underground and tie into the north side of the structure. Gas: The coverage over the existing services for both 104 and 108 will be compromised due to the access alterations. Services to both residences will be replaced in similar alignments to the existing services. For alterations to the existing utilities, see sheet C.05 for the demolition plan, and proposed utility work is shown on sheet C.06 of the civil drawings. Stormwater: All drainage infrastructure onsite will meet the requirements of the City of Aspen Urban Runoff Management Plan (URMP). CRC met with the engineering department to discuss feasibility, and it is agreed that the current design would be the recommended approach. It was determined that the existing stormwater within Midland Avenue may not have capacity for any site improvements at 108 Midland, so the engineering department encouraged the use of full detention of stormwater onsite. A new drywell is proposed on the neighboring property near the shared portion of the driveway. This drywell utilizes a trench drain to capture the majority of the stormwater off both driveways. A small area below the drywell cannot be collected due to slopes on the site. The drywell has been sized for full detention of a 100-year 1-hour storm event and will have no release of stormwater off the site. Two drywells are proposed on the property to provide full detention of runoff from all impervious improvements. One is located next to the fire truck turnaround to the south of the structure, and the other is proposed to the north. They are both sized for full detention and will not release any stormwater into the right-of-way. All conveyance structures will be sized to meet requirements of the URMP. For permit they will be analyzed to convey a 100-year 1-hour storm event at 80 percent capacity. Page 85 of 110 121278 Crystal River Civil LLC 970.510.5312 Page 5 of 5 Hazards: Given there are no floodplains, mudflows, snow flows, or known mine deposits the development does not impact any of these local hazards. Impacts to the existing slope hazards have been minimized as much as feasibly possible. Although the proposed design does impact the existing steep slopes, they were necessary to improve emergency access to the property. Additionally, all impacted areas are proposed to reduce steep slopes and minimize the manmade anomalies on the site. Several areas being impacted are for reconstruction of the deteriorating retaining walls along the Midland Avenue sidewalk. These impacted areas are represented on sheets C.03 and C.04 of the submitted civil drawings. If there are any comments regarding the design or the analysis performed for the site, feel free to contact me directly. Jay Engstrom Principal, P.E. Crystal River Civil LLC Jay@CrystalRiverCivil.com (970) 404 - 1144 Page 86 of 110 122279 123280 CITY OF ASPEN COMMUNITY DEVELOPMENT DEPARTMENT April 2020 City of Aspen|130 S. Galena St.|(970) 920 5090 Homeowner Association Compliance Policy All land use applications within the City of Aspen are required to include a Homeowner Association Compliance Form (this form) certifying the scope of work included in the land use application complies with all applicable covenants and homeowner association policies. The certification must be signed by the property owner or Attorney representing the property owner. Property Owner (“I”): Name: Email: Phone No.: Address of Property: (subject of application) I certify as follows: (pick one) □This property is not subject to a homeowners association or other form of private covenant. □This property is subject to a homeowners association or private covenant and the improvementsproposed in this land use application do not require approval by the homeowners association orcovenant beneficiary. □This property is subject to a homeowners association or private covenant and the improvementsproposed in this land use application have been approved by the homeowners association or covenant beneficiary. I understand this policy and I understand the City of Aspen does not interpret, enforce, or manage the applicability, meaning or effect of private covenants or homeowner association rules or bylaws. I understand that this document is a public document. Owner signature: date: Owner printed name: or, Attorney signature: date: Attorney printed name: Justin Haynes, Manager; Midland Properties LLC, a Texas limited liability company 108 Midland Avenue! Aspen, CO 81611 Justin Haynes Manager; Midland Properties LLC, a Texas limited liability company 6.13.22 Exhibit I.1 Page 88 of 110 124281 125282 Page 89 of 110 126283 300 SO SPRING ST | 202 | ASPEN, CO 81611 970.925.2855 | BENDONADAMS.COM July 30, 2022 Amy Simon Planning Director City of Aspen 427 Rio Grande Place Aspen, Colorado 81611 RE: 108 Midland Ave.; Aspen, CO Ms. Simon: Please accept this letter authorizing BendonAdams LLC to represent our ownership interests in 108 Midland Avenue and act on our behalf on matters reasonably associated in securing land use approvals for the property. If there are any questions about the foregoing or if I can assist, please do not hesitate to contact me. Property – 108 Midland Ave.; Aspen, CO Legal Description – Lot 1 of the Ferguson Exemption Plat Parcel ID – 2737-181-26-110 Owner – Midland Properties LLC, a Texas limited liability company Kind Regards, Justin Haynes, Manager Midland Properties LLC, a Texas limited liability company 808 N. 5th Street Alpine, TX 79830 Exhibit I.2 Page 90 of 110 127284 PRE-APPLICATION CONFERENCE SUMMARY PLANNER: Garrett Larimer, garrett.larimer@cityofaspen.com REPRESENTATIVE: Sara Adams, sara@bendonadams.com PROJECT LOCATION: 108 Midland Ave., Ferguson Subdivision REQUEST: Minor Amendment to a Planned Development DESCRIPTION: The subject site is zoned R-15a with a PD overlay. The potential applicant has indicated they would like to realign the driveway for Lot 1 (108 Midland Ave.) to be accessed directly from Midland Ave. Lot 1 is currently accessed through an access easement through Lot 4. A plat note on the Ferguson Exemption Plat (Bk. 11 Pg. 59) prohibits development on slopes that exceed 30% without approval from the Board of County Commissioners. The subdivision was approved by the Pitkin County Board of County Commissioners and subsequently annexed into the City of Aspen. The western and northern side of the property, and portions of the adjacent lots, contains slopes in excess of 30%. In order to develop a driveway off Midland Ave. in areas with slopes that exceed 30%, a Minor Amendment to a Planned Development is required to be approved by City Council. The application should clarify whether the application intends to allow for only a driveway within the areas containing slopes over 30%, or if they intend to eliminate restrictions on development in these areas entirely. The review process is the same but will be an important distinction for the review. The application will need to indicate the proposed alignment and dimensions or the driveway, curb cut and other improvements within the areas identified to contains slopes of 30% or greater on the plat. The existing easement across Lot 4 also contains utilities. A plan depicting existing and proposed utility alignments is required as part of the application. A draft plat meeting the Engineering Design Standards will need to be included in the application vacating the existing access and utility easement across Lot 4 and identifying the extents of development within the areas containing slopes exceeding 30% as identified on the plat. If the request is approved by City Council, the amended plat will be recorded with the Pitkin County Clerk and Recorders in addition to the Ordinance passed by City Council. A letter from the HOA approving the proposed realignment is required. A tree removal and proposed landscaping plan is required. Civil drawings indicating compliance with Engineering requirements for the driveway, utilities, and grading is required. The application will need to include written responses to Section 26.445.110.A. Parks and Engineering Departments will be referral agencies on the application. RELEVANT LAND USE CODE SECTIONS: Section Number Section Title 26.304 Common Development Review Procedures 26.445 Planned Developments 26.445.110.D Planned Development – Minor Amendment to the Project Review Approval For your convenience – links to the Land Use Application and Land Use Code are below: Exhibit I.3 Page 91 of 110 128285 Land Use Application Land Use Code Review by: Planning Staff for completeness and recommendation to Council Referrals for recommendation to Planning Staff Council for Decision by Ordinance (Requires 1st and 2nd Reading) Public Hearing: Yes, at City Council Neighborhood Outreach: No Referrals: Engineering - $325 deposit for 1 hr. staff time (Additional/ lesser hours will be billed/ refunded at a rate of $325 per hour.) Parks - $975 Flat fee Planning Fees: $4,550 deposit for 14 hours staff time (Additional/ lesser hours will be billed/ refunded at a rate of $325 per hour.) Total Deposit: $5,850 APPLICATION CHECKLIST: Below is a list of submittal requirements for review. Please email the entire application in a single pdf to garrett.larimer@cityofaspen.com. The fee will be requested after the application is determined to be complete.  Completed Land Use Application and signed Fee Agreement.  Completed Fee Waiver Request Form  Pre-application Conference Summary (this document).  Street address and legal description of the parcel on which development is proposed to occur, consisting of a current (no older than 6 months) certificate from a title insurance company, an ownership and encumbrance report, or attorney licensed to practice in the State of Colorado, listing the names of all owners of the property, and all mortgages, judgments, liens, easements, contracts and agreements affecting the parcel, and demonstrating the owner’s right to apply for the Development Application.  Applicant’s name, address and telephone number in a letter signed by the applicant that states the name, address and telephone number of the representative authorized to act on behalf of the applicant.  HOA Compliance form (Attached).  List of adjacent property owners for both properties within 300’ for public hearing.  An 8 1/2” by 11” vicinity map locating the parcel within the City of Aspen.  Site improvement survey including topography and vegetation showing the current status, certified by a registered land surveyor, licensed in the state of Colorado.  A written description of the proposal (scope of work) and written explanation of how the proposed development complies with the review standards and design guidelines relevant to the application. Page 92 of 110 129286  A statement prepared by a Colorado registered Professional Engineer, and depiction or mapping as necessary, regarding the presence of natural or man-made hazards affecting the property, including flooding, mudflow, debris flow, fault ruptures, landslides, rock or soil creep, rock falls, rock slides, mining activity including mine waste deposit, avalanche or snow slide areas, slopes in excess of thirty percent (30%), and any other natural or man-made hazard or condition that could harm the health, safety, or welfare of the community. Areas with slopes in excess of thirty percent (30%) shall require a slope stability study reviewed by the Colorado Geologic Survey. Also see Chapter 29—Engineering Design Standards regarding identification and mitigation of natural hazards.  A statement prepared by a Colorado registered Professional Engineer, and depiction or mapping as necessary, describing the potential infrastructure upgrades, alignment, design, and mitigation techniques that may be necessary for development of the site to be served by public infrastructure, achieve compliance with Municipal Code Title 29—Engineering Design Standards, and achieve compliance with the City of Aspen Urban Runoff Management Plan (URMP). The information shall be of sufficient detail to determine the acceptable location(s) and extent of development and to understand the necessary upgrades and the possible alignments, designs, or mitigation techniques that may be required.  A written response to each of the review criteria contained in Sections 26.445.050,  A grading and drainage plan showing all grading and how drainage and stormwater is accommodated, and that meets the Conceptual Drainage Plan and Report requirements in the Urban Runoff Management Plan (URMP).  Existing and proposed landscaping plan.  A draft plat meeting Engineering Design Standards. Disclaimer: The foregoing summary is advisory in nature only and is not binding on the City. The summary is based on current zoning, which is subject to change in the future, and upon factual representations that may or may not be accurate. The summary does not create a legal or vested right. Page 93 of 110 130287 CITY OF ASPEN COMMUNITY DEVELOPMENT DEPARTMENT City of Aspen|130 S. Galena St.|(970) 920 5090 April 2020 Agreement to Pay Application Fees Please type or print in all caps Representative Name (if different from Property Owner) Contact info for billing: e-mail: Phone: I understand that the City has adopted, via Ordinance No. 30, Series of 2017, review fees for Land Use applications and payment of these fees is a condition precedent to determining application completeness. I understand that as the property owner that I am responsible for paying all fees for this development application. For flat fees and referral fees: I agree to pay the following fees for the services indicated. I understand that these flat fees are non-refundable. $. flat fee for . $. flat fee for $. flat fee for . $. flat fee for For Deposit cases only: The City and I understand that because of the size, nature or scope of the proposed project, it is not possible at this time to know the full extent or total costs involved in processing the application. I understand that additional costs over and above the deposit may accrue. I understand and agree that it is impracticable for City staff to complete processing, review and presentation of sufficient information to enable legally required findings to be made for project consideration, unless invoices are paid in full. The City and I understand and agree that invoices mailed by the City to the above listed billing address and not returned to the City shall be considered by the City as being received by me. I agree to remit payment within 30 days of presentation of an invoice by the City for such services. I have read, understood, and agree to the Land Use Review Fee Policy including consequences for no-payment. I agree to pay the following initial deposit amounts for the specified hours of staff time. I understand that payment of a deposit does not render and application complete or compliant with approval criteria. If actual recorded costs exceed the initial deposit, I agree to pay additional monthly billings to the City to reimburse the City for the processing of my application at the hourly rates hereinafter stated. $ deposit for hours of Community Development Department staff time. Additional time above the deposit amount will be billed at $325.00 per hour. $ deposit for hours of Engineering Department staff time. Additional time above the deposit amount will be billed at $325.00 per hour. City of Aspen: Phillip Supino, AICP Community Development Director City Use: Fees Due: $ Received $ Case # Signature: PRINT Name: Title: BendonAdams An agreement between the City of Aspen (“City”) and Address of Property: Property Owner Name: 108 Midland Ave.; Aspen, CO 81611 Justin Haynes, Manager Midland Properties LLC, a Texas limited liability company Justin Haynes Manager; Midland Properties LLC, a Texas limited liability company Billing Name and Address - Send Bills to: 808 N. 5th Street; Alpine, TX AP@bigbend.com 432-364-0048 Exhibit I.4 Page 94 of 110 131288 INVOICE Land Title Guarantee Company 5975 Greenwood Plaza Blvd Suite 125 Greenwood Village, CO 80111 970-925-1678 BENDONADAMS LLC ERIN WACKERLE 300 S SPRING STREET SUITE 202 Aspen, CO 81611 Invoice Number:ASP-5037 Date: July 13, 2023 Order Number:62016319 Property Address:104 MIDLAND AVE ASPEN 81611 Invoice Charges Service: TBD Commitment Ref: 62016319 Addr: 104 MIDLAND AVE Party: RICKY C. SANDLER QUALIFIED PERSONAL RESIDENCE TRUST AND MARA SANDLER QUALIFIED PERSONAL RESIDENCE TRUST Total Amount Invoiced: Less Payment(s): Balance Due: $265.00 $265.00 $0.00 $265.00 Due and Payable upon receipt Please make check payable to Land Title Guarantee Company and send to the address at the top of Page 1. Please reference Invoice Number ASP-5037 on your Payment Page 1 invoice.odt 14420 07/2015 07/30/13 11:06:43 AM Reference Your Reference Number:TBD Commitment - 62016319 Our Order Number:ASP-5037 Our Customer Number:79636.2 Invoice Requested by:ERIN WACKERLE Invoice (Process) Date:July 13, 2023 Transaction Invoiced By:Web Services Email Address:system@ltgc.com 132289 Customer Distribution Prevent fraud - Please call a member of our closing team for wire transfer instructions or to initiate a wire transfer. Note that our wiring instructions will never change. Order Number: Q62016319 Date: 07/13/2023 Property Address: 104 MIDLAND AVE ASPEN, CO 81611 For Closing Assistance For Title Assistance Land Title Roaring Fork Valley Title Team 533 E HOPKINS #102 ASPEN, CO 81611 (970) 927-0405 (Work) (970) 925-0610 (Work Fax) valleyresponse@ltgc.com Seller/Owner RICKY C. SANDLER QUALIFIED PERSONAL RESIDENCE TRUST Delivered via: Electronic Mail BENDONADAMS LLC Attention: ERIN WACKERLE 300 S SPRING STREET SUITE 202 Aspen, CO 81611 (406) 531-0806 (Cell) (970) 925-2855 (Work) erin@bendonadams.com Delivered via: Electronic Mail Seller/Owner MARA SANDLER QUALIFIED PERSONAL RESIDENCE TRUST Delivered via: Electronic Mail 133290 Estimate of Title Fees Order Number: Q62016319 Date: 07/13/2023 Property Address: 104 MIDLAND AVE, ASPEN, CO 81611 Seller(s): RICKY C. SANDLER QUALIFIED PERSONAL RESIDENCE TRUST AND MARA SANDLER QUALIFIED PERSONAL RESIDENCE TRUST Buyer(s): Thank you for putting your trust in Land Title. Below is the estimate of title fees for the transaction. The final fees will be collected at closing. Visit ltgc.com to learn more about Land Title. Estimate of Title Insurance Fees "TBD" Commitment $265.00 TOTAL $265.00 Note: The documents linked in this commitment should be reviewed carefully. These documents, such as covenants conditions and restrictions, may affect the title, ownership and use of the property. You may wish to engage legal assistance in order to fully understand and be aware of the implications of the documents on your property. Chain of Title Documents: Pitkin county recorded 12/26/2012 under reception no. 595319 Pitkin county recorded 12/26/2012 under reception no. 595317 Pitkin county recorded 10/17/2006 under reception no. 529945 Pitkin county recorded 10/17/2006 under reception no. 529944 Pitkin county recorded 10/17/2006 under reception no. 529943 Pitkin county recorded 05/04/1994 at book 749 page 569 Pitkin county recorded 09/07/1988 at book 572 page 682 Plat Map(s): Pitkin county recorded 06/01/1981 under reception no. 233197 at book 11 page 59 134291 Copyright 2006-2023 American Land Title Association. All rights reserved. The use of this Form is restricted to ALTA licensees and ALTA members in good standing as of the date of use. All other uses are prohibited. Reprinted under license from the American Land Title Association. Property Address: 104 MIDLAND AVE, ASPEN, CO 81611 1.Effective Date: 06/30/2023 at 5:00 P.M. 2.Policy to be Issued and Proposed Insured: "TBD" Commitment Proposed Insured: $0.00 3.The estate or interest in the land described or referred to in this Commitment and covered herein is: FEE SIMPLE 4.Title to the estate or interest covered herein is at the effective date hereof vested in: RICKY C. SANDLER QUALIFIED PERSONAL RESIDENCE TRUST AND MARA SANDLER QUALIFIED PERSONAL RESIDENCE TRUST 5.The Land referred to in this Commitment is described as follows: LOT A, ACCORDING TO THE FERGUSON SUBDIVISION EXCEPTION AND PUD AMENDMENT PLAT RECORDED APRIL 30, 1986 IN PLAT BOOK 18 AT PAGE 66. ​ COUNTY OF PITKIN​ STATE OF COLORADO ALTA COMMITMENT Old Republic National Title Insurance Company Schedule A Order Number:Q62016319 135292 ALTA COMMITMENT Old Republic National Title Insurance Company Schedule B, Part I (Requirements) Order Number: Q62016319 All of the following Requirements must be met: This proposed Insured must notify the Company in writing of the name of any party not referred to in this Commitment who will obtain an interest in the Land or who will make a loan on the Land. The Company may then make additional Requirements or Exceptions. Pay the agreed amount for the estate or interest to be insured. Pay the premiums, fees, and charges for the Policy to the Company. Documents satisfactory to the Company that convey the Title or create the Mortgage to be insured, or both, must be properly authorized, executed, delivered, and recorded in the Public Records. THIS COMMITMENT IS FOR INFORMATION ONLY, AND NO POLICY WILL BE ISSUED PURSUANT HERETO. 136293 This commitment does not republish any covenants, condition, restriction, or limitation contained in any document referred to in this commitment to the extent that the specific covenant, conditions, restriction, or limitation violates state or federal law based on race, color, religion, sex, sexual orientation, gender identity, handicap, familial status, or national origin. 1.Any facts, rights, interests, or claims thereof, not shown by the Public Records but that could be ascertained by an inspection of the Land or that may be asserted by persons in possession of the Land. 2.Easements, liens or encumbrances, or claims thereof, not shown by the Public Records. 3.Any encroachment, encumbrance, violation, variation, or adverse circumstance affecting the Title that would be disclosed by an accurate and complete land survey of the Land and not shown by the Public Records. 4.Any lien, or right to a lien, for services, labor or material heretofore or hereafter furnished, imposed by law and not shown by the Public Records. 5.Defects, liens, encumbrances, adverse claims or other matters, if any, created, first appearing in the public records or attaching subsequent to the effective date hereof but prior to the date of the proposed insured acquires of record for value the estate or interest or mortgage thereon covered by this Commitment. 6.(a) Taxes or assessments that are not shown as existing liens by the records of any taxing authority that levies taxes or assessments on real property or by the Public Records; (b) proceedings by a public agency that may result in taxes or assessments, or notices of such proceedings, whether or not shown by the records of such agency or by the Public Records. 7.(a) Unpatented mining claims; (b) reservations or exceptions in patents or in Acts authorizing the issuance thereof; (c) water rights, claims or title to water. 8.RIGHT OF PROPRIETOR OF A VEIN OR LODE TO EXTRACT AND REMOVE HIS ORE THEREFROM SHOULD THE SAME BE FOUND TO PENETRATE OR INTERSECT THE PREMISES AS RESERVED IN UNITED STATES PATENT RECORDED JUNE 17, 1949, IN BOOK 175 AT PAGE 246. 9.RIGHT OF WAY FOR DITCHES AS SET FORTH IN INSTRUMENT RECORDED SEPTEMBER 3, 1947 IN BOOK 171 AT PAGE 315. 10.TERMS, CONDITIONS, PROVISIONS AND OBLIGATIONS AS SET FORTH IN RESOLUTION RECORDED SEPTEMBER 14, 1965 IN BOOK 215 AT PAGE 337. 11.TERMS, CONDITIONS, PROVISIONS AND OBLIGATIONS OF AGREEMENT RECORDED AUGUST 13, 1968 IN BOOK 235 AT PAGE 905. 12.TERMS, CONDITIONS, PROVISIONS AND OBLIGATIONS OF RESOLUTION NO. 80-1 OF THE BOARD OF COUNTY COMMISSIONERS OF PITKIN COUNTY, COLORADO RECORDED JANUARY 16, 1980 IN BOOK 382 AT PAGE 162. 13.TERMS, CONDITIONS, PROVISIONS AND OBLIGATIONS OF ORDINANCE NO 16, SERIES OF 1982 RECORDED JUNE 29, 1982 IN BOOK 428 AT PAGE 614 AND ORDINANCE NO. 18, SERIES OF 1982 RECORDED JULY 2, 1982 IN BOOK 428 AT PAGE 751. 14.TERMS, CONDITIONS, PROVISIONS AND OBLIGATIONS AS SET FORTH IN GRANT OF LICENSE RECORDED AUGUST 30, 1982 IN BOOK 431 AT PAGE 820. 15.TERMS, CONDITIONS, PROVISIONS AND OBLIGATIONS AS SET FORTH IN SUBSTITUTION OF EASEMENT RECORDED AUGUST 30, 1982 IN BOOK 431 AT PAGE 824 AND GRANT OF EASEMENT RECORDED AUGUST 30, 1982 IN BOOK 431 AT PAGE 828. ALTA COMMITMENT Old Republic National Title Insurance Company Schedule B, Part II (Exceptions) Order Number: Q62016319 137294 16.EASEMENTS, NOTES, RIGHTS OF WAY AND ALL MATTERS AS SHOWN ON FERGUSON EXEMPTION PLAT RECORDED JUNE 1, 1981 IN PLAT BOOK 11 AT PAGE 59 AND FERGUSON ANNEXATION PLAT RECORDED JUNE 29, 1981 IN PLAT BOOK 13 AT PAGE 65. 17.TERMS, CONDITIONS, PROVISIONS AND OBLIGATIONS OF EASEMENT USE RESTRICTION AGREEMENT RECORDED APRIL 5, 1984 IN BOOK 464 AT PAGE 233. 18.TERMS, CONDITIONS, PROVISIONS AND OBLIGATIONS OF STATEMENT OF EXCEPTION RECORDED APRIL 30, 1986 IN BOOK 509 AT PAGE 876. 19.TERMS, CONDITIONS, PROVISIONS AND OBLIGATIONS OF DECLARATION OF COVENANTS RECORDED APRIL 30, 1986 IN BOOK 509 AT PAGE 878. 20.EASEMENTS, NOTES, RIGHTS OF WAY AND ALL MATTERS AS SHOWN ON FERGUSON SUBDIVISION EXEMPTION PLAT RECORDED APRIL 30, 1986 IN PLAT BOOK 18 AT PAGE 66. 21.TERMS, CONDITIONS, PROVISIONS AND OBLIGATIONS OF STIPULATION RECORDED SEPTEMBER 15, 1995 IN BOOK 793 AT PAGE 709 AND DECREE RECORDED OCTOBER 18, 1995 IN BOOK 797 AT PAGE 149. 22.TERMS, CONDITIONS, PROVISIONS AND OBLIGATIONS AS SET FORTH IN EASEMENT RELOCATION AGREEMENT RECORDED DECEMBER 24, 2008 AS RECEPTION NO. 555278. 23.TERMS, CONDITIONS, PROVISIONS AND OBLIGATIONS AS SET FORTH IN REVOCABLE ENCROACHMENT LICENSE APPLICATION RECORDED JANUARY 5, 2010 AT RECEPTION NO. 565893. ALTA COMMITMENT Old Republic National Title Insurance Company Schedule B, Part II (Exceptions) Order Number: Q62016319 138295 Land Title Guarantee Company Disclosure Statements Note: Pursuant to CRS 10-11-122, notice is hereby given that: Note: Effective September 1, 1997, CRS 30-10-406 requires that all documents received for recording or filing in the clerk and recorder's office shall contain a top margin of at least one inch and a left, right and bottom margin of at least one half of an inch. The clerk and recorder may refuse to record or file any document that does not conform, except that, the requirement for the top margin shall not apply to documents using forms on which space is provided for recording or filing information at the top margin of the document. Note: Colorado Division of Insurance Regulations 8-1-2 requires that "Every title entity shall be responsible for all matters which appear of record prior to the time of recording whenever the title entity conducts the closing and is responsible for recording or filing of legal documents resulting from the transaction which was closed". Provided that Land Title Guarantee Company conducts the closing of the insured transaction and is responsible for recording the legal documents from the transaction, exception number 5 will not appear on the Owner's Title Policy and the Lenders Policy when issued. Note: Affirmative mechanic's lien protection for the Owner may be available (typically by deletion of Exception no. 4 of Schedule B, Section 2 of the Commitment from the Owner's Policy to be issued) upon compliance with the following conditions: No coverage will be given under any circumstances for labor or material for which the insured has contracted for or agreed to pay. Note: Pursuant to CRS 10-11-123, notice is hereby given: The Subject real property may be located in a special taxing district.(A) A certificate of taxes due listing each taxing jurisdiction will be obtained from the county treasurer of the county in which the real property is located or that county treasurer's authorized agent unless the proposed insured provides written instructions to the contrary. (for an Owner's Policy of Title Insurance pertaining to a sale of residential real property). (B) The information regarding special districts and the boundaries of such districts may be obtained from the Board of County Commissioners, the County Clerk and Recorder, or the County Assessor. (C) The land described in Schedule A of this commitment must be a single family residence which includes a condominium or townhouse unit. (A) No labor or materials have been furnished by mechanics or material-men for purposes of construction on the land described in Schedule A of this Commitment within the past 6 months. (B) The Company must receive an appropriate affidavit indemnifying the Company against un-filed mechanic's and material-men's liens. (C) The Company must receive payment of the appropriate premium.(D) If there has been construction, improvements or major repairs undertaken on the property to be purchased within six months prior to the Date of Commitment, the requirements to obtain coverage for unrecorded liens will include: disclosure of certain construction information; financial information as to the seller, the builder and or the contractor; payment of the appropriate premium fully executed Indemnity Agreements satisfactory to the company, and, any additional requirements as may be necessary after an examination of the aforesaid information by the Company. (E) 139296 This notice applies to owner's policy commitments disclosing that a mineral estate has been severed from the surface estate, in Schedule B-2. Note: Pursuant to CRS 10-1-128(6)(a), It is unlawful to knowingly provide false, incomplete, or misleading facts or information to an insurance company for the purpose of defrauding or attempting to defraud the company. Penalties may include imprisonment, fines, denial of insurance, and civil damages. Any insurance company or agent of an insurance company who knowingly provides false, incomplete, or misleading facts or information to a policyholder or claimant for the purpose of defrauding or attempting to defraud the policyholder or claimant with regard to a settlement or award payable from insurance proceeds shall be reported to the Colorado Division of Insurance within the Department of Regulatory Agencies. Note: Pursuant to Colorado Division of Insurance Regulations 8-1-3, notice is hereby given of the availability of a closing protection letter for the lender, purchaser, lessee or seller in connection with this transaction. Note: Pursuant to CRS 24-21-514.5, Colorado notaries may remotely notarize real estate deeds and other documents using real-time audio-video communication technology. You may choose not to use remote notarization for any document. That there is recorded evidence that a mineral estate has been severed, leased, or otherwise conveyed from the surface estate and that there is substantial likelihood that a third party holds some or all interest in oil, gas, other minerals, or geothermal energy in the property; and (A) That such mineral estate may include the right to enter and use the property without the surface owner's permission. (B) 140297 Joint Notice of Privacy Policy of Land Title Guarantee Company Land Title Guarantee Company of Summit County Land Title Insurance Corporation and Old Republic National Title Insurancy Company This Statement is provided to you as a customer of Land Title Guarantee Company as agent for Land Title Insurance Corporation and Old Republic National Title Insurance Company. We want you to know that we recognize and respect your privacy expectations and the requirements of federal and state privacy laws. Information security is one of our highest priorities. We recognize that maintaining your trust and confidence is the bedrock of our business. We maintain and regularly review internal and external safeguards against unauthorized access to your non-public personal information ("Personal Information"). In the course of our business, we may collect Personal Information about you from: applications or other forms we receive from you, including communications sent through TMX, our web-based transaction management system; your transactions with, or from the services being performed by us, our affiliates, or others; a consumer reporting agency, if such information is provided to us in connection with your transaction; and The public records maintained by governmental entities that we obtain either directly from those entities, or from our affiliates and non-affiliates. Our policies regarding the protection of the confidentiality and security of your Personal Information are as follows: We restrict access to all Personal Information about you to those employees who need to know that information in order to provide products and services to you. We may share your Personal Information with affiliated contractors or service providers who provide services in the course of our business, but only to the extent necessary for these providers to perform their services and to provide these services to you as may be required by your transaction. We maintain physical, electronic and procedural safeguards that comply with federal standards to protect your Personal Information from unauthorized access or intrusion. Employees who violate our strict policies and procedures regarding privacy are subject to disciplinary action. We regularly assess security standards and procedures to protect against unauthorized access to Personal Information. WE DO NOT DISCLOSE ANY PERSONAL INFORMATION ABOUT YOU WITH ANYONE FOR ANY PURPOSE THAT IS NOT STATED ABOVE OR PERMITTED BY LAW. Consistent with applicable privacy laws, there are some situations in which Personal Information may be disclosed. We may disclose your Personal Information when you direct or give us permission; when we are required by law to do so, for example, if we are served a subpoena; or when we suspect fraudulent or criminal activities. We also may disclose your Personal Information when otherwise permitted by applicable privacy laws such as, for example, when disclosure is needed to enforce our rights arising out of any agreement, transaction or relationship with you. 141298 Our policy regarding dispute resolution is as follows: Any controversy or claim arising out of or relating to our privacy policy, or the breach thereof, shall be settled by arbitration in accordance with the rules of the American Arbitration Association, and judgment upon the award rendered by the arbitrator(s) may be entered in any court having jurisdiction thereof. 142299 Commitment For Title Insurance Issued by Old Republic National Title Insurance Company NOTICE IMPORTANT—READ CAREFULLY: THIS COMMITMENT IS AN OFFER TO ISSUE ONE OR MORE TITLE INSURANCE POLICIES. ALL CLAIMS OR REMEDIES SOUGHT AGAINST THE COMPANY INVOLVING THE CONTENT OF THIS COMMITMENT OR THE POLICY MUST BE BASED SOLELY IN CONTRACT. THIS COMMITMENT IS NOT AN ABSTRACT OF TITLE, REPORT OF THE CONDITION OF TITLE, LEGAL OPINION, OPINION OF TITLE, OR OTHER REPRESENTATION OF THE STATUS OF TITLE. THE PROCEDURES USED BY THE COMPANY TO DETERMINE INSURABILITY OF THE TITLE, INCLUDING ANY SEARCH AND EXAMINATION, ARE PROPRIETARY TO THE COMPANY, WERE PERFORMED SOLELY FOR THE BENEFIT OF THE COMPANY, AND CREATE NO EXTRACONTRACTUAL LIABILITY TO ANY PERSON, INCLUDING A PROPOSED INSURED. THE COMPANY’S OBLIGATION UNDER THIS COMMITMENT IS TO ISSUE A POLICY TO A PROPOSED INSURED IDENTIFIED IN SCHEDULE A IN ACCORDANCE WITH THE TERMS AND PROVISIONS OF THIS COMMITMENT. THE COMPANY HAS NO LIABILITY OR OBLIGATION INVOLVING THE CONTENT OF THIS COMMITMENT TO ANY OTHER PERSON. . COMMITMENT TO ISSUE POLICY Subject to the Notice; Schedule B, Part I—Requirements; Schedule B, Part II—Exceptions; and the Commitment Conditions, Old Republic National Title Insurance Company, a Minnesota corporation (the “Company”), commits to issue the Policy according to the terms and provisions of this Commitment. This Commitment is effective as of the Commitment Date shown in Schedule A for each Policy described in Schedule A, only when the Company has entered in Schedule A both the specified dollar amount as the Proposed Policy Amount and the name of the Proposed Insured. If all of the Schedule B, Part I—Requirements have not been met within 6 months after the Commitment Date, this Commitment terminates and the Company’s liability and obligation end. COMMITMENT CONDITIONS 1. DEFINITIONS 2. If all of the Schedule B, Part I—Requirements have not been met within the time period specified in the Commitment to Issue Policy, Commitment terminates and the Company’s liability and obligation end. 3. The Company’s liability and obligation is limited by and this Commitment is not valid without: 4. COMPANY’S RIGHT TO AMEND The Company may amend this Commitment at any time. If the Company amends this Commitment to add a defect, lien, encumbrance, adverse claim, or other matter recorded in the Public Records prior to the Commitment Date, any liability of the Company is limited by Commitment Condition 5. The Company shall not be liable for any other amendment to this Commitment. 5. LIMITATIONS OF LIABILITY i. comply with the Schedule B, Part I—Requirements; ii. eliminate, with the Company’s written consent, any Schedule B, Part II—Exceptions; or iii. acquire the Title or create the Mortgage covered by this Commitment. 6. LIABILITY OF THE COMPANY MUST BE BASED ON THIS COMMITMENT “Knowledge” or “Known”: Actual or imputed knowledge, but not constructive notice imparted by the Public Records.(a) “Land”: The land described in Schedule A and affixed improvements that by law constitute real property. The term “Land” does not include any property beyond the lines of the area described in Schedule A, nor any right, title, interest, estate, or easement in abutting streets, roads, avenues, alleys, lanes, ways, or waterways, but this does not modify or limit the extent that a right of access to and from the Land is to be insured by the Policy. (b) “Mortgage”: A mortgage, deed of trust, or other security instrument, including one evidenced by electronic means authorized by law.(c) “Policy”: Each contract of title insurance, in a form adopted by the American Land Title Association, issued or to be issued by the Company pursuant to this Commitment. (d) “Proposed Insured”: Each person identified in Schedule A as the Proposed Insured of each Policy to be issued pursuant to this Commitment.(e) “Proposed Policy Amount”: Each dollar amount specified in Schedule A as the Proposed Policy Amount of each Policy to be issued pursuant to this Commitment. (f) “Public Records”: Records established under state statutes at the Commitment Date for the purpose of imparting constructive notice of matters relating to real property to purchasers for value and without Knowledge. (g) “Title”: The estate or interest described in Schedule A.(h) the Notice;(a) the Commitment to Issue Policy;(b) the Commitment Conditions;(c) Schedule A;(d) Schedule B, Part I—Requirements; and(e) Schedule B, Part II—Exceptions; and(f) a counter-signature by the Company or its issuing agent that may be in electronic form.(g) The Company’s liability under Commitment Condition 4 is limited to the Proposed Insured’s actual expense incurred in the interval between the Company’s delivery to the Proposed Insured of the Commitment and the delivery of the amended Commitment, resulting from the Proposed Insured’s good faith reliance to: (a) The Company shall not be liable under Commitment Condition 5(a) if the Proposed Insured requested the amendment or had Knowledge of the matter and did not notify the Company about it in writing. (b) The Company will only have liability under Commitment Condition 4 if the Proposed Insured would not have incurred the expense had the Commitment included the added matter when the Commitment was first delivered to the Proposed Insured. (c) The Company’s liability shall not exceed the lesser of the Proposed Insured’s actual expense incurred in good faith and described in Commitment Conditions 5(a)(i) through 5(a)(iii) or the Proposed Policy Amount. (d) The Company shall not be liable for the content of the Transaction Identification Data, if any.(e) In no event shall the Company be obligated to issue the Policy referred to in this Commitment unless all of the Schedule B, Part I—Requirements have been met to the satisfaction of the Company. (f) In any event, the Company’s liability is limited by the terms and provisions of the Policy.(g) Only a Proposed Insured identified in Schedule A, and no other person, may make a claim under this Commitment.(a) Any claim must be based in contract and must be restricted solely to the terms and provisions of this Commitment.(b) Until the Policy is issued, this Commitment, as last revised, is the exclusive and entire agreement between the parties with respect to the subject matter of this Commitment and supersedes all prior commitment negotiations, representations, and proposals of any kind, whether written or oral, express or implied, relating to the subject matter of this Commitment. (c) 143300 7. IF THIS COMMITMENT HAS BEEN ISSUED BY AN ISSUING AGENT The issuing agent is the Company’s agent only for the limited purpose of issuing title insurance commitments and policies. The issuing agent is not the Company’s agent for the purpose of providing closing or settlement services. 8. PRO-FORMA POLICY The Company may provide, at the request of a Proposed Insured, a pro-forma policy illustrating the coverage that the Company may provide. A pro-forma policy neither reflects the status of Title at the time that the pro-forma policy is delivered to a Proposed Insured, nor is it a commitment to insure. 9. ARBITRATION The Policy contains an arbitration clause. All arbitrable matters when the Proposed Policy Amount is $2,000,000 or less shall be arbitrated at the option of either the Company or the Proposed Insured as the exclusive remedy of the parties. A Proposed Insured may review a copy of the arbitration rules at http://www.alta.org/arbitration. IN WITNESS WHEREOF, Land Title Insurance Corporation has caused its corporate name and seal to be affixed by its duly authorized officers on the date shown in Schedule A to be valid when countersigned by a validating officer or other authorized signatory. Issued by: Land Title Guarantee Company 3033 East First Avenue Suite 600 Denver, Colorado 80206 303-321-1880 Craig B. Rants, Senior Vice President This page is only a part of a 2016 ALTA® Commitment for Title Insurance issued by Old Republic National Title Insurance Company. This Commitment is not valid without the Notice; the Commitment to Issue Policy; the Commitment Conditions; Schedule A; Schedule B, Part I—Requirements; and Schedule B, Part II —Exceptions; and a counter-signature by the Company or its issuing agent that may be in electronic form. Copyright 2006-2016 American Land Title Association. All rights reserved. The use of this Form (or any derivative thereof) is restricted to ALTA licensees and ALTA members in good standing as of the date of use. All other uses are prohibited. Reprinted under license from the American Land Title Association. The deletion or modification of any Schedule B, Part II—Exception does not constitute an agreement or obligation to provide coverage beyond the terms and provisions of this Commitment or the Policy. (d) Any amendment or endorsement to this Commitment must be in writing and authenticated by a person authorized by the Company.(e) When the Policy is issued, all liability and obligation under this Commitment will end and the Company’s only liability will be under the Policy.(f) 144301 Land Title Guarantee Company Customer Distribution PREVENT FRAUD - Please remember to call a member of our closing team when initiating a wire transfer or providing wiring instructions. Order Number:Q62014472-4 Date: 01/18/2023 Property Address:108 MIDLAND AVE, ASPEN, CO 81611 PLEASE CONTACT YOUR CLOSER OR CLOSER'S ASSISTANT FOR WIRE TRANSFER INSTRUCTIONS For Closing Assistance For Title Assistance Land Title Roaring Fork Valley Title Team 533 E HOPKINS #102 ASPEN, CO 81611 (970) 927-0405 (Work) (970) 925-0610 (Work Fax) valleyresponse@ltgc.com Seller/Owner MIDLAND PROPERTIES LLC Delivered via: Delivered by Realtor COLDWELL BANKER MASON MORSE REAL ESTATE Attention: JUSTIN CLARENCE 514 E HYMAN AVE ASPEN, CO 81611 (970) 688-1804 (Cell) (970) 925-7000 (Work) (970) 925-7027 (Work Fax) judd@aspenluxurybrokers.com Delivered via: Electronic Mail BENDONADAMS Attention: ERIN WACKERLE 300 S SPRING STREET SUITE 202 Aspen, CO 81611 (406) 531-0806 (Cell) (970) 925-2855 (Work) erin@bendonadams.com Delivered via: Electronic Mail Exhibit I.5 Page 95 of 110 145302 Land Title Guarantee Company Estimate of Title Fees Order Number:Q62014472-4 Date: 01/18/2023 Property Address:108 MIDLAND AVE, ASPEN, CO 81611 Parties:A BUYER TO BE DETERMINED MIDLAND PROPERTIES LLC, A TEXAS LIMITED LIABILITY COMPANY Visit Land Title's Website at www.ltgc.com for directions to any of our offices. Estimate of Title insurance Fees "TBD" Commitment $265.00 TBD - TBD Income $-265.00 Total $0.00 If Land Title Guarantee Company will be closing this transaction, the fees listed above will be collected at closing. Thank you for your order! Note: The documents linked in this commitment should be reviewed carefully. These documents, such as covenants conditions and restrictions, may affect the title, ownership and use of the property. You may wish to engage legal assistance in order to fully understand and be aware of the implications of the effect of these documents on your property. Chain of Title Documents: Pitkin county recorded 04/20/2020 under reception no. 664148 Plat Map(s): Pitkin county recorded 06/01/1981 under reception no. 233197 at book 11 page 59 Page 96 of 110 146303 Copyright 2006-2023 American Land Title Association. All rights reserved. The use of this Form is restricted to ALTA licensees and ALTA members in good standing as of the date of use. All other uses are prohibited. Reprinted under license from the American Land Title Association. Property Address: 108 MIDLAND AVE, ASPEN, CO 81611 1.Effective Date: 12/30/2022 at 5:00 P.M. 2.Policy to be Issued and Proposed Insured: "TBD" Commitment Proposed Insured: A BUYER TO BE DETERMINED $0.00 3.The estate or interest in the land described or referred to in this Commitment and covered herein is: A FEE SIMPLE 4.Title to the estate or interest covered herein is at the effective date hereof vested in: MIDLAND PROPERTIES LLC, A TEXAS LIMITED LIABILITY COMPANY 5.The Land referred to in this Commitment is described as follows: LOT 1, ​ FERGUSON EXEMPTION PLAT,​ ACCORDING TO THE PLAT THEREOF RECORDED JUNE 1, 1981 IN PLAT BOOK 11 AT PAGE 59 AS RECEPTION NO. 233197.​ COUNTY OF PITKIN​ STATE OF COLORADO ALTA COMMITMENT Old Republic National Title Insurance Company Schedule A Order Number:Q62014472-4 Page 97 of 110 147304 ALTA COMMITMENT Old Republic National Title Insurance Company Schedule B, Part I (Requirements) Order Number: Q62014472-4 All of the following Requirements must be met: This proposed Insured must notify the Company in writing of the name of any party not referred to in this Commitment who will obtain an interest in the Land or who will make a loan on the Land. The Company may then make additional Requirements or Exceptions. Pay the agreed amount for the estate or interest to be insured. Pay the premiums, fees, and charges for the Policy to the Company. Documents satisfactory to the Company that convey the Title or create the Mortgage to be insured, or both, must be properly authorized, executed, delivered, and recorded in the Public Records. The following will be required should the Company be requested to issue a future commitment to insure: 1.EVIDENCE SATISFACTORY TO THE COMPANY THAT THE TERMS, CONDITIONS AND PROVISIONS OF THE CITY OF ASPEN TRANSFER TAX HAVE BEEN SATISFIED. 2.RELEASE OF DEED OF TRUST DATED APRIL 17, 2020 FROM MIDLAND PROPERTIES LLC, A TEXAS LIMITED LIABILITY COMPANY TO THE PUBLIC TRUSTEE OF PITKIN COUNTY FOR THE USE OF THE NATIONAL BANK OF TEXAS AT FORT WORTH TO SECURE THE SUM OF $4,183,000.00 RECORDED APRIL 20, 2020, UNDER RECEPTION NO. 664151. 3.CERTIFICATE OF GOOD STANDING FROM THE SECRETARY OF STATE OR OTHER APPROPRIATE OFFICER OF THE STATE OF TEXAS, SHOWING THAT MIDLAND PROPERTIES LLC, A TEXAS LIMITED LIABILITY COMPANY IS A DULY ORGANIZED AND EXISTING ENTITY UNDER THE LAWS OF SAID STATE. 4.WRITTEN CONFIRMATION THAT THE INFORMATION CONTAINED IN STATEMENT OF AUTHORITY FOR MIDLAND PROPERTIES LLC, A TEXAS LIMITED LIABILITY COMPANY RECORDED APRIL 20, 2020 UNDER RECEPTION NO. 664152 IS CURRENT. NOTE: SAID INSTRUMENT DISCLOSES JUSTIN HAYNES AS THE MANAGER AUTHORIZED TO EXECUTE INSTRUMENTS CONVEYING, ENCUMBERING OR OTHERWISE AFFECTING TITLE TO REAL PROPERTY ON BEHALF OF SAID ENTITY. IF THIS INFORMATION IS NOT ACCURATE, A CURRENT STATEMENT OF AUTHORITY MUST BE RECORDED. 5.GOOD AND SUFFICIENT DEED FROM MIDLAND PROPERTIES LLC, A TEXAS LIMITED LIABILITY COMPANY TO A BUYER TO BE DETERMINED CONVEYING SUBJECT PROPERTY. NOTE: ADDITIONAL REQUIREMENTS OR EXCEPTIONS MAY BE NECESSARY WHEN THE BUYERS NAMES ARE ADDED TO THIS COMMITMENT. COVERAGES AND/OR CHARGES REFLECTED HEREIN, IF ANY, ARE SUBJECT TO CHANGE UPON RECEIPT OF THE CONTRACT TO BUY AND SELL REAL ESTATE AND ANY AMENDMENTS THERETO. THIS COMMITMENT IS FOR INFORMATION ONLY, AND NO POLICY WILL BE ISSUED PURSUANT HERETO. Page 98 of 110 148305 This commitment does not republish any covenants, condition, restriction, or limitation contained in any document referred to in this commitment to the extent that the specific covenant, conditions, restriction, or limitation violates state or federal law based on race, color, religion, sex, sexual orientation, gender identity, handicap, familial status, or national origin. 1.Any facts, rights, interests, or claims thereof, not shown by the Public Records but that could be ascertained by an inspection of the Land or that may be asserted by persons in possession of the Land. 2.Easements, liens or encumbrances, or claims thereof, not shown by the Public Records. 3.Any encroachment, encumbrance, violation, variation, or adverse circumstance affecting the Title that would be disclosed by an accurate and complete land survey of the Land and not shown by the Public Records. 4.Any lien, or right to a lien, for services, labor or material heretofore or hereafter furnished, imposed by law and not shown by the Public Records. 5.Defects, liens, encumbrances, adverse claims or other matters, if any, created, first appearing in the public records or attaching subsequent to the effective date hereof but prior to the date of the proposed insured acquires of record for value the estate or interest or mortgage thereon covered by this Commitment. 6.(a) Taxes or assessments that are not shown as existing liens by the records of any taxing authority that levies taxes or assessments on real property or by the Public Records; (b) proceedings by a public agency that may result in taxes or assessments, or notices of such proceedings, whether or not shown by the records of such agency or by the Public Records. 7.(a) Unpatented mining claims; (b) reservations or exceptions in patents or in Acts authorizing the issuance thereof; (c) water rights, claims or title to water. 8.RIGHT OF PROPRIETOR OF A VEIN OR LODE TO EXTRACT AND REMOVE HIS ORE THEREFROM SHOULD THE SAME BE FOUND TO PENETRATE OR INTERSECT THE PREMISES AS RESERVED IN UNITED STATES PATENT RECORDED JUNE 17, 1949, IN BOOK 175 AT PAGE 246. 9.RIGHT OF WAY FOR DITCHES AS SET FORTH IN INSTRUMENT RECORDED SEPTEMBER 3, 1947 IN BOOK 171 AT PAGE 315. 10.TERMS, CONDITIONS, PROVISIONS AND OBLIGATIONS OF RESOLUTION NO. 80-1 OF THE BOARD OF COUNTY COMMISSIONERS OF PITKIN COUNTY, COLORADO RECORDED JANUARY 16, 1980 IN BOOK 382 AT PAGE 162. 11.TERMS, CONDITIONS, PROVISIONS AND OBLIGATIONS AS SET FORTH IN RESOLUTION RECORDED SEPTEMBER 14, 1965 IN BOOK 215 AT PAGE 337. 12.TERMS, CONDITIONS, PROVISIONS AND OBLIGATIONS OF ORDINANCE NO 16, SERIES OF 1982 RECORDED JUNE 29, 1982 IN BOOK 428 AT PAGE 614 AND ORDINANCE NO. 18, SERIES OF 1982 RECORDED JULY 2, 1982 IN BOOK 428 AT PAGE 751. 13.TERMS, CONDITIONS, PROVISIONS AND OBLIGATIONS AS SET FORTH IN GRANT OF LICENSE RECORDED AUGUST 30, 1982 IN BOOK 431 AT PAGE 820. ALTA COMMITMENT Old Republic National Title Insurance Company Schedule B, Part II (Exceptions) Order Number: Q62014472-4 Page 99 of 110 149306 14.TERMS, CONDITIONS, PROVISIONS AND OBLIGATIONS AS SET FORTH IN GRANT OF EASEMENT RECORDED AUGUST 30, 1982 IN BOOK 431 AT PAGE 828 AND LETTER AGREEMENT RECORDED SEPTEMBER 1, 1982 IN BOOK 432 AT PAGE 30. 15.EASEMENTS, NOTES, RIGHTS OF WAY AND ALL MATTERS AS SHOWN ON FERGUSON EXEMPTION PLAT RECORDED JUNE 1, 1981 IN PLAT BOOK 11 AT PAGE 59 AND FERGUSON ANNEXATION PLAT RECORDED JUNE 29, 1981 IN PLAT BOOK 13 AT PAGE 65. 16.TERMS, CONDITIONS, PROVISIONS AND OBLIGATIONS OF EASEMENT USE RESTRICTION AGREEMENT RECORDED APRIL 5, 1984 IN BOOK 464 AT PAGE 233. 17.TERMS, CONDITIONS, PROVISIONS AND OBLIGATIONS AS SET FORTH IN EASEMENT RELOCATION AGREEMENT RECORDED DECEMBER 24, 2008 AS RECEPTION NO. 555278. 18.EASEMENTS, NOTES, RIGHTS OF WAY AND ALL MATTERS AS SHOWN ON FERGUSON SUBDIVISION EXEMPTION PLAT RECORDED APRIL 30, 1986 IN PLAT BOOK 18 AT PAGE 66. 19.TERMS, CONDITIONS, PROVISIONS AND OBLIGATIONS AS SET FORTH IN REVOCABLE ENCROACHMENT LICENSE APPLICATION RECORDED JANUARY 5, 2010 AT RECEPTION NO. 565893. 20.TERMS, CONDITIONS AND PROVISIONS OF NOTICE OF APPROVAL RECORDED DECEMBER 07, 2022 UNDER RECEPTION NO. 691900. 21.ANY FACTS, RIGHTS, INTERESTS OR CLAIMS WHICH MAY EXIST OR ARISE BY REASON OF THE FOLLOWING FACTS SHOWN ON IMPROVEMENT SURVEY CERTIFIED FEBRUARY 13, 2015 AND REVISED FEBRUARY 19, 2020 PREPARED BY THE SEXTON SURVEY COMPANY, JOB NO. 15003 OUR ESI 37921609 AND OUR ESI 37921715: ENCROACHMENT OF RETAINING WALLS OUTSIDE PROPERTY LINE UNDERGROUND TELEPHONE LINES UNDERGROUND CABLE TV LINES OVERHEAD UTILITY LINES UNDERGROUND GAS LINES WATER LINES 22.CLAIMS OF RIGHT, TITLE AND/OR INTEREST IN THE PROPERTY BETWEEN THE BOUNDARY LINE AND THE FENCE AS DEPICTED ON THE SURVEY PREPARED BY THE SEXTON SURVEY COMPANY, JOB NO. 15003 WHETHER SAID CLAIMS ARISE BY ABANDONMENT, ADVERSE POSSESSION OR OTHER MEANS. SAID DOCUMENT STORE AS OUR ESI 37921609 ALTA COMMITMENT Old Republic National Title Insurance Company Schedule B, Part II (Exceptions) Order Number: Q62014472-4 Page 100 of 110 150307 LAND TITLE GUARANTEE COMPANY DISCLOSURE STATEMENTS Note: Pursuant to CRS 10-11-122, notice is hereby given that: Note: Effective September 1, 1997, CRS 30-10-406 requires that all documents received for recording or filing in the clerk and recorder's office shall contain a top margin of at least one inch and a left, right and bottom margin of at least one half of an inch. The clerk and recorder may refuse to record or file any document that does not conform, except that, the requirement for the top margin shall not apply to documents using forms on which space is provided for recording or filing information at the top margin of the document. Note: Colorado Division of Insurance Regulations 8-1-2 requires that "Every title entity shall be responsible for all matters which appear of record prior to the time of recording whenever the title entity conducts the closing and is responsible for recording or filing of legal documents resulting from the transaction which was closed". Provided that Land Title Guarantee Company conducts the closing of the insured transaction and is responsible for recording the legal documents from the transaction, exception number 5 will not appear on the Owner's Title Policy and the Lenders Policy when issued. Note: Affirmative mechanic's lien protection for the Owner may be available (typically by deletion of Exception no. 4 of Schedule B, Section 2 of the Commitment from the Owner's Policy to be issued) upon compliance with the following conditions: No coverage will be given under any circumstances for labor or material for which the insured has contracted for or agreed to pay. The Subject real property may be located in a special taxing district.(A) A certificate of taxes due listing each taxing jurisdiction will be obtained from the county treasurer of the county in which the real property is located or that county treasurer's authorized agent unless the proposed insured provides written instructions to the contrary. (for an Owner's Policy of Title Insurance pertaining to a sale of residential real property). (B) The information regarding special districts and the boundaries of such districts may be obtained from the Board of County Commissioners, the County Clerk and Recorder, or the County Assessor. (C) The land described in Schedule A of this commitment must be a single family residence which includes a condominium or townhouse unit. (A) No labor or materials have been furnished by mechanics or material-men for purposes of construction on the land described in Schedule A of this Commitment within the past 6 months. (B) The Company must receive an appropriate affidavit indemnifying the Company against un-filed mechanic's and material-men's liens. (C) The Company must receive payment of the appropriate premium.(D) If there has been construction, improvements or major repairs undertaken on the property to be purchased within six months prior to the Date of Commitment, the requirements to obtain coverage for unrecorded liens will include: disclosure of certain construction information; financial information as to the seller, the builder and or the contractor; payment of the appropriate premium fully executed Indemnity Agreements satisfactory to the company, and, any additional requirements as may be necessary after an examination of the aforesaid information by the Company. (E) Page 101 of 110 151308 Note: Pursuant to CRS 10-11-123, notice is hereby given: This notice applies to owner's policy commitments disclosing that a mineral estate has been severed from the surface estate, in Schedule B-2. Note: Pursuant to CRS 10-1-128(6)(a), It is unlawful to knowingly provide false, incomplete, or misleading facts or information to an insurance company for the purpose of defrauding or attempting to defraud the company. Penalties may include imprisonment, fines, denial of insurance, and civil damages. Any insurance company or agent of an insurance company who knowingly provides false, incomplete, or misleading facts or information to a policyholder or claimant for the purpose of defrauding or attempting to defraud the policyholder or claimant with regard to a settlement or award payable from insurance proceeds shall be reported to the Colorado Division of Insurance within the Department of Regulatory Agencies. Note: Pursuant to Colorado Division of Insurance Regulations 8-1-3, notice is hereby given of the availability of a closing protection letter for the lender, purchaser, lessee or seller in connection with this transaction. Note: Pursuant to CRS 10-1-11(4)(a)(1), Colorado notaries may remotely notarize real estate deeds and other documents using real-time audio-video communication technology. You may choose not to use remote notarization for any document. That there is recorded evidence that a mineral estate has been severed, leased, or otherwise conveyed from the surface estate and that there is substantial likelihood that a third party holds some or all interest in oil, gas, other minerals, or geothermal energy in the property; and (A) That such mineral estate may include the right to enter and use the property without the surface owner's permission. (B) Page 102 of 110 152309 JOINT NOTICE OF PRIVACY POLICY OF LAND TITLE GUARANTEE COMPANY, LAND TITLE GUARANTEE COMPANY OF SUMMIT COUNTY LAND TITLE INSURANCE CORPORATION AND OLD REPUBLIC NATIONAL TITLE INSURANCE COMPANY This Statement is provided to you as a customer of Land Title Guarantee Company as agent for Land Title Insurance Corporation and Old Republic National Title Insurance Company. We want you to know that we recognize and respect your privacy expectations and the requirements of federal and state privacy laws. Information security is one of our highest priorities. We recognize that maintaining your trust and confidence is the bedrock of our business. We maintain and regularly review internal and external safeguards against unauthorized access to your non-public personal information ("Personal Information"). In the course of our business, we may collect Personal Information about you from: applications or other forms we receive from you, including communications sent through TMX, our web-based transaction management system; your transactions with, or from the services being performed by us, our affiliates, or others; a consumer reporting agency, if such information is provided to us in connection with your transaction; and The public records maintained by governmental entities that we obtain either directly from those entities, or from our affiliates and non-affiliates. Our policies regarding the protection of the confidentiality and security of your Personal Information are as follows: We restrict access to all Personal Information about you to those employees who need to know that information in order to provide products and services to you. We may share your Personal Information with affiliated contractors or service providers who provide services in the course of our business, but only to the extent necessary for these providers to perform their services and to provide these services to you as may be required by your transaction. We maintain physical, electronic and procedural safeguards that comply with federal standards to protect your Personal Information from unauthorized access or intrusion. Employees who violate our strict policies and procedures regarding privacy are subject to disciplinary action. We regularly assess security standards and procedures to protect against unauthorized access to Personal Information. WE DO NOT DISCLOSE ANY PERSONAL INFORMATION ABOUT YOU WITH ANYONE FOR ANY PURPOSE THAT IS NOT STATED ABOVE OR PERMITTED BY LAW. Consistent with applicable privacy laws, there are some situations in which Personal Information may be disclosed. We may disclose your Personal Information when you direct or give us permission; when we are required by law to do so, for example, if we are served a subpoena; or when we suspect fraudulent or criminal activities. We also may disclose your Personal Information when otherwise permitted by applicable privacy laws such as, for example, when disclosure is needed to enforce our rights arising out of any agreement, transaction or relationship with you. Our policy regarding dispute resolution is as follows: Any controversy or claim arising out of or relating to our privacy policy, or the breach thereof, shall be settled by arbitration in accordance with the rules of the American Arbitration Association, and judgment upon the award rendered by the arbitrator(s) may be entered in any court having jurisdiction thereof. Page 103 of 110 153310 Commitment For Title Insurance Issued by Old Republic National Title Insurance Company NOTICE IMPORTANT—READ CAREFULLY: THIS COMMITMENT IS AN OFFER TO ISSUE ONE OR MORE TITLE INSURANCE POLICIES. ALL CLAIMS OR REMEDIES SOUGHT AGAINST THE COMPANY INVOLVING THE CONTENT OF THIS COMMITMENT OR THE POLICY MUST BE BASED SOLELY IN CONTRACT. THIS COMMITMENT IS NOT AN ABSTRACT OF TITLE, REPORT OF THE CONDITION OF TITLE, LEGAL OPINION, OPINION OF TITLE, OR OTHER REPRESENTATION OF THE STATUS OF TITLE. THE PROCEDURES USED BY THE COMPANY TO DETERMINE INSURABILITY OF THE TITLE, INCLUDING ANY SEARCH AND EXAMINATION, ARE PROPRIETARY TO THE COMPANY, WERE PERFORMED SOLELY FOR THE BENEFIT OF THE COMPANY, AND CREATE NO EXTRACONTRACTUAL LIABILITY TO ANY PERSON, INCLUDING A PROPOSED INSURED. THE COMPANY’S OBLIGATION UNDER THIS COMMITMENT IS TO ISSUE A POLICY TO A PROPOSED INSURED IDENTIFIED IN SCHEDULE A IN ACCORDANCE WITH THE TERMS AND PROVISIONS OF THIS COMMITMENT. THE COMPANY HAS NO LIABILITY OR OBLIGATION INVOLVING THE CONTENT OF THIS COMMITMENT TO ANY OTHER PERSON. . COMMITMENT TO ISSUE POLICY Subject to the Notice; Schedule B, Part I—Requirements; Schedule B, Part II—Exceptions; and the Commitment Conditions, Old Republic National Title Insurance Company, a Minnesota corporation (the “Company”), commits to issue the Policy according to the terms and provisions of this Commitment. This Commitment is effective as of the Commitment Date shown in Schedule A for each Policy described in Schedule A, only when the Company has entered in Schedule A both the specified dollar amount as the Proposed Policy Amount and the name of the Proposed Insured. If all of the Schedule B, Part I—Requirements have not been met within 6 months after the Commitment Date, this Commitment terminates and the Company’s liability and obligation end. COMMITMENT CONDITIONS 1. DEFINITIONS 2. If all of the Schedule B, Part I—Requirements have not been met within the time period specified in the Commitment to Issue Policy, Commitment terminates and the Company’s liability and obligation end. 3. The Company’s liability and obligation is limited by and this Commitment is not valid without: 4. COMPANY’S RIGHT TO AMEND The Company may amend this Commitment at any time. If the Company amends this Commitment to add a defect, lien, encumbrance, adverse claim, or other matter recorded in the Public Records prior to the Commitment Date, any liability of the Company is limited by Commitment Condition 5. The Company shall not be liable for any other amendment to this Commitment. 5. LIMITATIONS OF LIABILITY i. comply with the Schedule B, Part I—Requirements; ii. eliminate, with the Company’s written consent, any Schedule B, Part II—Exceptions; or iii. acquire the Title or create the Mortgage covered by this Commitment. “Knowledge” or “Known”: Actual or imputed knowledge, but not constructive notice imparted by the Public Records.(a) “Land”: The land described in Schedule A and affixed improvements that by law constitute real property. The term “Land” does not include any property beyond the lines of the area described in Schedule A, nor any right, title, interest, estate, or easement in abutting streets, roads, avenues, alleys, lanes, ways, or waterways, but this does not modify or limit the extent that a right of access to and from the Land is to be insured by the Policy. (b) “Mortgage”: A mortgage, deed of trust, or other security instrument, including one evidenced by electronic means authorized by law.(c) “Policy”: Each contract of title insurance, in a form adopted by the American Land Title Association, issued or to be issued by the Company pursuant to this Commitment. (d) “Proposed Insured”: Each person identified in Schedule A as the Proposed Insured of each Policy to be issued pursuant to this Commitment.(e) “Proposed Policy Amount”: Each dollar amount specified in Schedule A as the Proposed Policy Amount of each Policy to be issued pursuant to this Commitment. (f) “Public Records”: Records established under state statutes at the Commitment Date for the purpose of imparting constructive notice of matters relating to real property to purchasers for value and without Knowledge. (g) “Title”: The estate or interest described in Schedule A.(h) the Notice;(a) the Commitment to Issue Policy;(b) the Commitment Conditions;(c) Schedule A;(d) Schedule B, Part I—Requirements; and(e) Schedule B, Part II—Exceptions; and(f) a counter-signature by the Company or its issuing agent that may be in electronic form.(g) The Company’s liability under Commitment Condition 4 is limited to the Proposed Insured’s actual expense incurred in the interval between the Company’s delivery to the Proposed Insured of the Commitment and the delivery of the amended Commitment, resulting from the Proposed Insured’s good faith reliance to: (a) The Company shall not be liable under Commitment Condition 5(a) if the Proposed Insured requested the amendment or had Knowledge of the matter and did not notify the Company about it in writing. (b) The Company will only have liability under Commitment Condition 4 if the Proposed Insured would not have incurred the expense had the Commitment included the added matter when the Commitment was first delivered to the Proposed Insured. (c) The Company’s liability shall not exceed the lesser of the Proposed Insured’s actual expense incurred in good faith and described in Commitment Conditions 5(a)(i) through 5(a)(iii) or the Proposed Policy Amount. (d) The Company shall not be liable for the content of the Transaction Identification Data, if any.(e) Page 104 of 110 154311 6. LIABILITY OF THE COMPANY MUST BE BASED ON THIS COMMITMENT 7. IF THIS COMMITMENT HAS BEEN ISSUED BY AN ISSUING AGENT The issuing agent is the Company’s agent only for the limited purpose of issuing title insurance commitments and policies. The issuing agent is not the Company’s agent for the purpose of providing closing or settlement services. 8. PRO-FORMA POLICY The Company may provide, at the request of a Proposed Insured, a pro-forma policy illustrating the coverage that the Company may provide. A pro-forma policy neither reflects the status of Title at the time that the pro-forma policy is delivered to a Proposed Insured, nor is it a commitment to insure. 9. ARBITRATION The Policy contains an arbitration clause. All arbitrable matters when the Proposed Policy Amount is $2,000,000 or less shall be arbitrated at the option of either the Company or the Proposed Insured as the exclusive remedy of the parties. A Proposed Insured may review a copy of the arbitration rules at http://www.alta.org/arbitration. IN WITNESS WHEREOF, Land Title Insurance Corporation has caused its corporate name and seal to be affixed by its duly authorized officers on the date shown in Schedule A to be valid when countersigned by a validating officer or other authorized signatory. Issued by: Land Title Guarantee Company 3033 East First Avenue Suite 600 Denver, Colorado 80206 303-321-1880 Craig B. Rants, Senior Vice President This page is only a part of a 2016 ALTA® Commitment for Title Insurance issued by Old Republic National Title Insurance Company. This Commitment is not valid without the Notice; the Commitment to Issue Policy; the Commitment Conditions; Schedule A; Schedule B, Part I—Requirements; and Schedule B, Part II —Exceptions; and a counter-signature by the Company or its issuing agent that may be in electronic form. Copyright 2006-2016 American Land Title Association. All rights reserved. The use of this Form (or any derivative thereof) is restricted to ALTA licensees and ALTA members in good standing as of the date of use. All other uses are prohibited. Reprinted under license from the American Land Title Association. In no event shall the Company be obligated to issue the Policy referred to in this Commitment unless all of the Schedule B, Part I—Requirements have been met to the satisfaction of the Company. (f) In any event, the Company’s liability is limited by the terms and provisions of the Policy.(g) Only a Proposed Insured identified in Schedule A, and no other person, may make a claim under this Commitment.(a) Any claim must be based in contract and must be restricted solely to the terms and provisions of this Commitment.(b) Until the Policy is issued, this Commitment, as last revised, is the exclusive and entire agreement between the parties with respect to the subject matter of this Commitment and supersedes all prior commitment negotiations, representations, and proposals of any kind, whether written or oral, express or implied, relating to the subject matter of this Commitment. (c) The deletion or modification of any Schedule B, Part II—Exception does not constitute an agreement or obligation to provide coverage beyond the terms and provisions of this Commitment or the Policy. (d) Any amendment or endorsement to this Commitment must be in writing and authenticated by a person authorized by the Company.(e) When the Policy is issued, all liability and obligation under this Commitment will end and the Company’s only liability will be under the Policy.(f) Page 105 of 110 155312 Pitkin County Mailing List of 300 Feet Radius Pitkin County GIS presents the information and data on this web site as a service to the public. Every effort has been made to ensure that the information and data contained in this electronic system is accurate, but the accuracy may change. The information maintained by the County may not be complete as to mineral estate ownership and that information should be determined by separate legal and property analysis. Pitkin County GIS makes no warranty or guarantee concerning the completeness, accuracy, or reliability of the content at this site or at other sites to which we link. Assessing accuracy and reliability of information and data is the sole responsibility of the user. The user understands he or she is solely responsible and liable for use, modification, or distribution of any information or data obtained on this web site. This document contains a Mailing List formatted to be printed on Avery 5160 Labels. If printing, DO NOT "fit to page" or "shrink oversized pages." This will manipulate the margins such that they no longer line up on the labels sheet. Print actual size. From Parcel: 273718126110 on 01/30/2023 Instructions: Disclaimer: http://www.pitkinmapsandmore.com Exhibit I.6 Page 106 of 110 156313 111 & 115 PARK AVE TOWNHOME CONDO ASSOC ASPEN, CO 81611 111 PARK AVE 121 ROBINSON ROAD LLC ASPEN, CO 81611 323 W MAIN ST #100 131 MIDLAND LLC SEDALIA, CO 80135 7547 DANIELS PARK RD 139 ROBINSON RD CABIN LLC AUSTIN, TX 78731 3902 WATERS EDGE DR 17A&B LLC SAN FRANCISCO , CA 94123 2625 BAKER ST ADAIR DUPLEX CONDO ASSOC ASPEN, CO 81611 COMMON AREA 126 PARK AVE ALPINE COTTAGES CONDO ASSOC ASPEN, CO 81611 ROBINSON RD ASPEN EDGE CONDO ASSOC ASPEN, CO 81611 1235 E COOPER AVE ASPEN FIN HOME LLC MIAMI, FL 33180 2999 NE 191ST ST #800 ASPEN SCHOOL DISTRICT #1 ASPEN, CO 81611 0235 HIGH SCHOOL RD ASPEN/PITKIN COUNTY HOUSING AUTHORITY ASPEN, CO 81611 18 TRUSCOTT PL BEACH CATHERINE A ASPEN, CO 816112415 311 LACET CT BEIDLEMAN NEAL J & AMY G ASPEN, CO 81612 PO BOX 4362 BENNETT NEIL JAY REV TRUST ASPEN, CO 81611 214 PARK AVE BILCHAK ROSEMARY HOTCHKISS, CO 81419 410 DUKE HILL RD BOLERJACK LISA ASPEN, CO 81611 308 KATHRYNS WAY BROWN DONALD ASPEN, CO 81611-2405 412 KATHRYNS WY BRRRR LLC SAN ANTONIO, TX 78209 120 AUSTIN HWY STE 105 BURKLEY RICHARD & ROBERTA ASPEN, CO 81611-2381 106 ROBINSON DR #F CANTRELL WESLEY R ASPEN, CO 81611-2405 104 KATHRYNS WY CAPSHAW-TAYLOR MICHAEL THOMAS ASPEN, CO 81611 514 KATHRYNS WY #E-11 CASTLE CREEK DEVELOPMENT LLC HOUSTON, TX 77027 4295 SAN FELIPE ST STE 306 CAUDILL ROBERT M & JANICE VOS ASPEN, CO 81611 118 ROBINSON RD CAVE DERYK REV TRUST ASPEN, CO 81611 1195 E COOPER AVE CITY OF ASPEN ASPEN, CO 81611 427 RIO GRANDE PL CLAUSS DUNCAN ASPEN, CO 81611 101 KATHRYNS WY #A-1 CLULEY ELIZABETH ASPEN, CO 816112144 104 LACET CT COOPER DOOPER LLC ALBUQUERQUE, NM 87107 4610 RIO GRANDE LN CORBIN MARCIA A ASPEN, CO 81612 PO BOX 9312 DEELGUEA ALEJANDRO ORTIZ ASPEN, CO 81612 PO BOX 9871 Page 107 of 110 157314 DEJEAN FELIX A III & CAROLYNE OPELOUSAS, LA 70570 1368 KATHERINE DR DEROSE JAMES F & MAUREEN C CHICAGO, IL 60661 333 N DESPLANES ST DOYLE JOHN F & LAURIE FRAMPTON ASPEN, CO 81612 PO BOX 12236 EAST COOPER TOWNHOME HOA ASPEN, CO 81611 LACET CT EE PARK DALE WEST LLC ATLANTA, GA 30328 750 HAMMOND DR BLDG 6 #300 EISENSTAT DAVID H & NINA ASPEN, CO 81611 125 PARK AVE ELLIOTT ELYSE A TRUST ASPEN, CO 81611 610 NORTH ST EMERSON LINDSEY ASPEN, CO 81611 102 LACET CT ERNST TERSIA V ASPEN, CO 81611-2405 206 KATHRYNS WY FAAS MICHAEL & MJ WOLFE ASPEN, CO 816112381 116 ROBINSON RD FAHY ROBIN A & HARVEY V ASPEN, CO 81612 PO BOX 4348 FISCHER BETH A ASPEN, CO 81611 208 LACET CT FORTIER LINDSY S & ADAM J ASPEN, CO 81611 205 LACET CT #205 GLICK DANIEL ASPEN, CO 81612 PO BOX 9910 GROSZ COLLEEN A TRUST CHICAGO, IL 60601 155 N HARBOR DR #3612 HAILEY JOHN T ASPEN, CO 81611 100 ROBINSON RD HAMLIN CONNIE ASPEN, CO 81611 207 LACET CT HAWKEN MADELEINE ASPEN, CO 81612 PO BOX 3695 HENRY LORI ANNE ASPEN, CO 81611 450 S RIVERSIDE AVE #B HENRY PHINEAS P IRREV TRUST ASPEN, CO 81611 450 S RIVERSIDE DR #B ILIC KSENIJA D ASPEN, CO 81612 PO BOX 504 ITTNER ROBERT A JR & ROBERT A SR ASPEN, CO 816128965 PO BOX 8965 JIMENEZ LETITIA M ASPEN, CO 81611 206 LACET CT LAFOUNTAINE ANTOINETTE ASPEN, CO 81611 410 KATHRYNS WY #D1 LAKEVIEW TOWNHOME CONDO ASSOC ASPEN, CO 81611 COMMON AREA MIDLAND AVE LAUGHREN DANA ASPEN, CO 81611 205 KATHRYNS WY #B1 LEAVITT DEREK C LIV TRUST MARINA DEL REY, CA 90292 4712 ADMIRALTY WAY #561 LEAVITT FAMILY TRUST MARINA DEL REY, CA 90292 4712 ADMIRALTY WY #561 LEAVITT GRANT O LIV TRUST MARINA DEL REY, CA 90292 4712 ADMIRALTY WAY #561 LEAVITT LAURA LIV TRUST MARINA DEL REY, CA 90292 4712 ADMIRALTY WAY #561 Page 108 of 110 158315 LEBBY FAMILY TRUST ASPEN, CO 81612 PO BOX 1352 LEE PENNIE ASPEN, CO 81611 450 S RIVERSIDE AVE #A LEVENTHAL ROBERT B ASPEN, CO 81611-2405 515 KATHRYNS WY #E-2 LONGHORN 6603 LLC FORT WORTH, TX 76107 2200 CANTERBURY DR MACALPINE GORDON A ASPEN , CO 81612 PO BOX 5043 MANDRIN VENTURES LLC ASPEN, CO 81611 101 S MILL ST #200 MARGARET MEADOWS LOT 2 CONDO ASSOC ASPEN, CO 81611 COMMON AREA 110 PARK AVE MILLER DAVID W ASPEN, CO 81611 110 ROBINSON RD #D MILLER DAWN & STEPHEN H COCONUT GROVE, FL 33133 3401 N MOORINGS WAY MOLLY GIBSON LOOP CONDO ASSOC ASPEN, CO 81611 COMMON AREA 450 S RIVERSIDE DR NICOLETTI PAUL J III TRUST ASPEN, CO 81611 1180 DALE AVE NOVAK THEODORE J TRUST CHICAGO, IL 60614 618 W DEMING PL OCONNER PHILIP ASPEN, CO 81611 114 ROBINSON RD OKSENHORN CANDICE ASPEN, CO 81611 102 ROBINSON RD OKSENHORN STEWART ASPEN, CO 81611 102 ROBINSON DR OLITSKY STEPHEN L & TAMAR ASPEN, CO 81611 257 PARK AVE P & P ASPEN LLC ASPEN, CO 81611 411 LACET LN PARK DALE TOWNHOMES CONDO ASSOC ASPEN, CO 81611 COMMON AREA 101 DALE AVE PARK/DALE RESIDENCES CONDO ASSOC ASPEN, CO 81611 COMMON AREA 257 PARK AVE POWER MATTHEW ASPEN, CO 81611 207 LACET CT PRICE LINDA J TRUST WOODBRIDGE , NJ 07095 100 WOODBRIDGE CENTER DR REDMOND JOHN D ASPEN, CO 81611 207 KATHRYNS WY RIESSEN MICHAEL ASPEN, CO 81611 313 LACET CT RODBELL PHYLLIS ATLANTA, GA 30327 1101 CREST VALLEY DR RODELL TIMOTHY C & MARJORIE M ASPEN, CO 81612-8005 PO BOX 8005 SACHS SARAH & HARRISON R ASPEN, CO 81611 403 LACET CT SANDLER LIVING TRUST PARADISE VALLEY , AZ 81611 6427 E LUKE AVE SANDLER MARA QPR TRUST NEW YORK, NY 10022 399 PARK AVE #26FL SANDLER RICKY C QPR TRUST NEW YORK, NY 10027 65 E 55TH ST 25TH FL SANDS ALESHA M ASPEN, CO 81611 112 ROBINSON RD #1 Page 109 of 110 159316 SCARLETT ROBIN ASPEN, CO 81611-2405 413 KATHRYNS WY SCHIFF SANFORD M ASPEN, CO 81612 PO BOX 8491 SIKAT 2018 PROPERTY TRUST TORONTO ONTARIO M9P 1R4 CANADA, 3 WESTMOUNT PARK RD SILVA GUSTAVO S ASPEN, CO 81611 112 ROBINSON RD SILVER LAKE FAMILY TRUST ASPEN, CO 81611 128 PARK AVE SMITH JASON ASPEN, CO 81612 PO BOX 3695 SMUGGLER LOOP CONDO ASSOC ASPEN, CO 81611 COMMON AREA 1195 E COOPER AVE SNYDER CONDO ASSOC ASPEN, CO 81611 600 KATHRYNS WAY SUTHREN MARTIN T ASPEN, CO 81611 312 LACET CT TUROK SETH J ASPEN, CO 81611 208 LACET CT UTE EAST RESIDENCES CONDO ASSOC ASPEN, CO 81611 COMMON AREA 1245 E COOPER AVE VOSS ELIZA MAUK & RYANPETER ASPEN, CO 81611 104 ROBINSON RD WELLS RICHARD ASPEN, CO 81612 PO BOX 4867 WHITEASPEN LLC KEY BISCAYNE, FL 33149 30 ISLAND DR WHITEHURST PROPERTIES LLC BALTIMORE, MD 21212 6504 MONTROSE AVE WILSON KIMBERLY ASPEN, CO 81611 102 KATHRYNS WY #A2 WOERNDLE SUB HOA ASPEN, CO 81611 101 S MILL ST #200 WWSP3G LLC ASPEN, CO 81612 PO BOX 4290 YEAGER JAMES W ASPEN, CO 81611 310 LACET CT ZALE MILTON TRUST CHICAGO, IL 60613 3824 N ASHLAND AVE Page 110 of 110 160317 CITY OF ASPEN STANDARD FORM OF AGREEMENT SUPPLY PROCUREMENT City of Aspen Project No.: 2023-226 AGREEMENT made as of 10th day of July, in the year 2022. BETWEEN the City: Contract Amount: And the Vendor: Summary Description of Items to be Purchased: Exhibits appended and made a part of this Agreement: If this Agreement requires the City to pay an amount of money in excess of $50,000.00 it shall not be deemed valid until it has been approved by the City Council of the City of Aspen. City Council Approval: Date: 7/25/2023 Resolution No.: #109 The City of Aspen c/o Wheeler Opera House 427 Rio Grande Place Aspen, Colorado 81611 Phone: (970) 920-5055 Total: $70,750.00 Barbizon Light of the Rockies 8269 East 23rd Avenue Suite 111 Denver, CO 80238 (303) 394-9875 pmaurelli@barbizon.com One (1) grandMA3 Full Size lighting console and flight case. Exhibit A: Bid Proposal including Items to be Purchased and Fee DocuSign Envelope ID: A22C5AD8-5308-42E6-B27C-276BF608F383 10318 The City and Vendor agree as set forth below. 1. Purchase. Vendor agrees to sell and City agrees to purchase the items on Exhibit A appended hereto and by this reference incorporated herein as if fully set forth here for the sum set forth hereinabove. 2. Delivery. (FOB 320 E Hyman Ave, Aspen, CO, 81611) [Delivery Address] 3. Contract Documents. This Agreement shall include all Contract Documents as the same are listed in the Invitation to Bid and said Contract Document are hereby made a part of this Agreement as if fully set out at length herein. 4. Warranties. 5. Successors and Assigns. This Agreement and all of the covenants hereof shall inure to the benefit of and be binding upon the City and the Vendor respectively and their agents, representatives, employee, successors, assigns and legal representatives. Neither the City nor the Vendor shall have the right to assign, transfer or sublet its interest or obligations hereunder without the written consent of the other party. 6. Third Parties. This Agreement does not and shall not be deemed or construed to confer upon or grant to any third party or parties, except to parties to whom Vendor or City may assign this Agreement in accordance with the specific written permission, any right to claim damages or to bring any suit, action or other proceeding against either the City or Vendor because of any breach hereof or because of any of the terms, covenants, agreements or conditions herein contained. 7. Waivers. No waiver of default by either party of any of the terms, covenants or conditions hereof to be performed, kept and observed by the other party shall be construed, or operate as, a waiver of any subsequent default of any of the terms, covenants or conditions herein contained, to be performed, kept and observed by the other party. 8. Agreement Made in Colorado. The parties agree that this Agreement was made in accordance with the laws of the State of Colorado and shall be so construed. Venue is agreed to be exclusively in the courts of Pitkin County, Colorado. 9. Attorney’s Fees. In the event that legal action is necessary to enforce any of the provisions of this Agreement, the prevailing party shall be entitled to its costs and reasonable attorney’s fees. 10. Waiver of Presumption. This Agreement was negotiated and reviewed through the mutual efforts of the parties hereto and the parties agree that no construction shall be made or presumption shall arise for or against either party based on any alleged unequal status of the parties in the negotiation, review or drafting of the Agreement. DocuSign Envelope ID: A22C5AD8-5308-42E6-B27C-276BF608F383 11319 11. Certification Regarding Debarment, Suspension, Ineligibility, and Voluntary Exclusion. Vendor certifies, by acceptance of this Agreement, that neither it nor its principals is presently debarred, suspended, proposed for debarment, declared ineligible or voluntarily excluded from participation in any transaction with a Federal or State department or agency. It further certifies that prior to submitting its Bid that it did include this clause without modification in all lower tier transactions, solicitations, proposals, contracts and subcontracts. In the event that Vendor or any lower tier participant was unable to certify to the statement, an explanation was attached to the Bid and was determined by the City to be satisfactory to the City. 12. Warranties Against Contingent Fees, Gratuities, Kickbacks and Conflicts of Interest. (A) Vendor warrants that no person or selling agency has been employed or retained to solicit or secure this Contract upon an agreement or understanding for a commission, percentage, brokerage, or contingent fee, excepting bona fide employees or bon a fide established commercial or selling agencies maintained by the Vendor for the purpose of securing business. (B) Vendor agrees not to give any employee of the City a gratuity or any offer of employment in connection with any decision, approval, disapproval, recommendation, preparation of any part of a program requirement or a purchase request, influencing the content of any specification or procurement standard, rendering advice, investigation, auditing, or in any other advisory capacity in any proceeding or application, request for ruling, determination, claim or controversy, or other particular matter, pertaining to this Agreement, or to any solicitation or proposal therefore. (C) Vendor represents that no official, officer, employee or representative of the City during the term of this Agreement has or one (1) year thereafter shall have any interest, direct or indirect, in this Agreement or the proceeds thereof, except those that may have been disclosed at the time City Council approved the execution of this Agreement. (D) In addition to other remedies it may have for breach of the prohibitions against contingent fees, gratuities, kickbacks and conflict of interest, the City shall have the right to: 1. Cancel this Purchase Agreement without any liability by the City; 2. Debar or suspend the offending parties from being a vendor, contractor or subcontractor under City contracts; 3. Deduct from the contract price or consideration, or otherwise recover, the value of anything transferred or received by the Vendor; and 4. Recover such value from the offending parties. 13. Termination for Default or for Convenience of City. The sale contemplated by this Agreement may be canceled by the City prior to acceptance by the City whenever for any reason and in its sole discretion the City shall determine that such cancellation is in its best interests and convenience. DocuSign Envelope ID: A22C5AD8-5308-42E6-B27C-276BF608F383 12320 14. Fund Availability. Financial obligations of the City payable after the current fiscal year are contingent upon funds for that purpose being appropriated, budgeted and otherwise made available. If this Agreement contemplates the City using state or federal funds to meet its obligations herein, this Agreement shall be contingent upon the availability of those funds for payment pursuant to the terms of this Agreement. 15. City Council Approval. If this Agreement requires the City to pay an amount of money in excess of $50,000.00 it shall not be deemed valid until it has been approved by the City Council of the City of Aspen. 16. Non-Discrimination. No discrimination because of race, color, creed, sex, marital status, affectional or sexual orientation, family responsibility, national origin, ancestry, handicap, or religion shall be made in the employment of persons to perform under this Agreement. Vendor agrees to meet all of the requirements of City’s municipal code, section 13-98, pertaining to nondiscrimination in employment. Vendor further agrees to comply with the letter and the spirit of the Colorado Antidiscrimination Act of 1957, as amended and other applicable state and federal laws respecting discrimination and unfair employment practices. 17. Integration and Modification. This written Agreement along with all Contract Documents shall constitute the contract between the parties and supersedes or incorporates any prior written and oral agreements of the parties. In addition, vendor understands that no City official or employee, other than the Mayor and City Council acting as a body at a council meeting, has authority to enter into an Agreement or to modify the terms of the Agreement on behalf of the City. Any such Agreement or modification to this Agreement must be in writing and be executed by the parties hereto. 18. Authorized Representative. The undersigned representative of Vendor, as an inducement to the City to execute this Agreement, represents that he/she is an authorized representative of Vendor for the purposes of executing this Agreement and that he/she has full and complete authority to enter into this Agreement for the terms and conditions specified herein. 19. Electronic Signatures and Electronic Records This Agreement and any amendments hereto may be executed in several counterparts, each of which shall be deemed an original, and all of which together shall constitute one agreement binding on the Parties, notwithstanding the possible event that all Parties may not have signed the same counterpart. Furthermore, each Party consents to the use of electronic signatures by either Party. The Scope of Work, and any other documents requiring a signature hereunder, may be signed electronically in the manner agreed to by the Parties. The Parties agree not to deny the legal effect or enforceability of the Agreement solely because it is in electronic form or because an electronic record was used in its formation. The Parties agree not to object to the admissibility of the Agreement in the form of an electronic record, or a paper copy of an electronic documents, or a paper copy of a document bearing an electronic signature, on the ground that it is an electronic record or electronic signature or that it is not in its original form or is not an original. DocuSign Envelope ID: A22C5AD8-5308-42E6-B27C-276BF608F383 13321 IN WITNESS WHEREOF, The City and the Vendor, respectively have caused this Agreement to be duly executed the day and year first herein, of which, to all intents and purposes, shall be considered as the original. FOR THE CITY OF ASPEN: By: Aspen City Manager Date SUPPLIER: By: Title Date Approved as to form: City Attorney’s Office DocuSign Envelope ID: A22C5AD8-5308-42E6-B27C-276BF608F383 Systems Integrator 7/11/2023 | 8:33:08 PM MDT Peter Maurelli 14322 EXHIBIT A: BID PROPOSAL DocuSign Envelope ID: A22C5AD8-5308-42E6-B27C-276BF608F383 15323 DocuSign Envelope ID: A22C5AD8-5308-42E6-B27C-276BF608F383 16324