Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
File Documents.108 Midland Ave.0264.2017 (16).ARBK
aec Architectural Engineering Consultants, Inc. Mechanical,Electrical,&Lighting Design Services An Office with LEEDTM Accredited Professionals Warm Roof Assembly Worksheet Project: Sandler Residence AEC Project Number: 17017 Date: 6/27/2017 Calculated By: Bryan Urban Thermal Resistance of Assembly-Typical Roof Thickness Component R-Value Outside air Layer 0.17 Varies Water-proof Membrane 0.2 5/8" Plywood 0.77 6" Tapered Rigid Insulation 12.5 5/8" Plywood 0.77 6" Spray Foam Insulation 37.5 5/8" Gypsum Board 0.56 Inside Air Layer 0.65 Rew 51.91 Rt.! 53.12 Re,a R Value of the Exterior Sheating Rtotai R Value of the Total Roof Assembly Tin Interior Temperature(70°) Tout Exterior Temperature(Assuming-20.0°) Tinterface Temperature at the Rigid/Batt Insulation Interface Tinterface Re,n / Rtotal * (Tin - Tout) + Tout Tinterface 51.91 53.12 70 -20 -20 Tinterface 67.9°F Dewpoint at 30%Relative Humidity 37.2°F Dewpoint at 35%Relative Humidity 41.1°F The temperature of the foam/batt insulation interface is 67.9°F. Therefore,the resulting dew point of 41.1°F would occur in the exterior impermeable insulation,which verifies compliance. RECEIVED 10/16/2017 ASPEN BUILDING DEPARTMENT ZINC STANDING SEAM METAL ROOFING SLOPE REF. PLANS 2 LAYERS FIRE-RESISTANT SELF ADHERING WATERPROOFING MEMBRANE (GAF VERSASHIELD FR. ESR-2053) N - 2" RIGID INSULATION WITH NAIL BASE R-12 !: PLYWOOD SHEATHING REF. STRUCT. DWGS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . rn . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6" SPRAY FOAM INSULATION R-37.5 ROOF JOISTS REF. STRUCTURAL DRAWINGS 1/2" PLYWOOD SHEATHING T&G WOOD REF. RCP AND FINISH SCHEDULE CLASS 'A' ROOF ASSEMBLY R-1 METAL ROOF SCALE 1 1/2" = 1'-0" RECEIVED 10/16/2017 ASPEN BUILDING DEPARTMENT 90 MIL. FIRE RESISTANT SELF- ADHERING EPDM ROOFING MEMBRANE SLOPE (FIRESTONE RUBBERGUARD LS-FR. REF. ROOF PLAN ESR-3026) w OSB NAIL BASE TAPERED RIGID INSULATION MECHANICALLY FASTEND TO DECK 1/4" PER FT. SLOPE TO DRAIN l 2 1/2" MIN. THICKNESS AT DRAINS . R-12.5 . . . . . . . . . . . . . . . . . . . . . . . . . PLYWOOD SHEATHING REF. STRUCT. DWGS. 6" SPRAY FOAM INSULATION :, .. R-37.5 ROOF JOISTS REF. STRUCTURAL DRAWINGS CEILING FINISH REF. REFLECTED CLG PLANS FOR HEIGHTS AND FINISHES CLASS 'A' ROOF ASSEMBLY R-2 LOW SLOPE ROOF SCALE 1 1/2" = 1'-0" RECEIVED 10/16/2017 ASPEN BUILDING DEPARTMENT