HomeMy WebLinkAboutFile Documents.835 E Hyman Ave.0064.2018 (2).ARBK Mule-Hide Products, Co., Inc. Page: 9
Underwriters laboratories (UL)
Roofing Systems-TPO Revised Sept-2016
CLASS A—FULLY ADHERED
1. Deck: NC Incline: 1
Insulation: —Any UL Certified wood fiberboard; Johns Manville "ENRGY 3 Plus"
(composite) insulation; cellular concrete, precast concrete with grouted joints or
structural (poured-in-place) concrete.
Membrane: —"Mule-Hide TPO-c (FR)", fully adhered with "Mule-Hide TPO-c Bonding
Adhesive", at 1-1/3 gal/100-ft.2.
2. Deck: NC Incline: 1/2
Insulation: —"Poly ISO 1" or"Poly ISO 2" or Atlas Roofing Corp. "ACFoam II",
"ACFoam III" or Dow "Hy-Therm AP" or Hunter Panels "H-Shield" or Johns Manville
"ENRGY-3" or Firestone Building Products "ISO 95+GL", "OW' or"HF" or Rmax
Operating LLC "Multi-Max-3", any combination, any thickness.
Membrane: —"Mule-Hide TPO-c (FR)", fully adhered with "Mule-Hide TPO-c Bonding
Adhesive", at 1-1/3 gal/100-ft.2.
3. Deck: C-15/32 Incline: Unlimited
Insulation (Optional): —Any UL Certified, any combination, any thickness.
Barrier Board: — Minimum '/2-in. gypsum board or minimum %-in. thick Georgia-Pacific
Gypsum LLC "DensDeck® Roofboard", "DensDeck Prime® Roofboard", "DensDeck
DuraGuardTM Roofboard".
Membrane: —"Mule-Hide TPO-c (FR)", fully adhered with "Mule-Hide TPO-c Bonding
Adhesive"at 1-1/3 gal/100-ft.2.
4. Deck: C-15/32 Incline: See Note
Slip Sheet: —Two layers GAF "VersaShield Underlayment" or"VersaShield FB-2S".
Insulation: —Any UL Certified (except EPS), any combination, any thickness.
Membrane: —"Mule-Hide TPO-c", "Mule-Hide TPO-c (FR)", "Mule-Hide TPO-c Extra",
"Mule-Hide TPO-c Extra (FR)" or"Mule-Hide TPO-c Fleece Back".
Note: Maximum incline shall be in accordance with Certification established for the
insulation/membrane roofing system, but cannot exceed 2:12.
5. Deck: C-15/32 Incline: See Note
Slip Sheet: —One layer Atlas Roofing Corp. "FR-10" or"FR-50" or GAF "VersaShield
Underlayment" or"VersaShield FB-2S".
Insulation: —Atlas Roofing "ACFoam III", minimum 1.5-in. thick with joints staggered
minimum 6-in. from the deck joints.
Membrane: —"Mule-Hide TPO-c", "Mule-Hide TPO-c (FR)", "Mule-Hide TPO-c Extra",
"Mule-Hide TPO-c Extra (FR)" or"Mule-Hide TPO-c Fleece Back".
Note: Maximum incline shall be in accordance with Certification established for
the insulation/membrane roofing system.
1195 Prince Hall Dr. 608-365-3111 e, Fax: 608-365-7852 ' www.mulehide.com PREil,.1 IVED
Beloit,WI 53511-5481 Beloit, WI 53512-1057
11-2110 04/02/2018
ASPEN
BUILDING DEPARTMENT
`'' MULE-HIDE Product Data Sheet
• PRODUCTS MULE-HIDE TPO-c MEMBRANE
(Standard, FR and CLEAN Film)
3.0
PRODUCT DESCRIPTION ,4f
Mule-Hide's TPO-c Membrane is a polyester reinforced, .045"or.060 thick,
polyolefin based,thermoplastic, heat-weldable membrane. High breaking ; , 4/
strength,tearing strength,and puncture resistance is achieved by L
encapsulating a strong polyester fabric between the top and bottom plies.
Mule-Hide TPO-c FR membrane is formulated with additional flame retardant I.
(compared to Standard)for higher slope fire code approvals. The Mule-Hide • „ €
TPO-c membrane is also available in a 0.80"thickness(see Product Data '<,•-` •
Sheet for TPO-c EXTRA). The membrane is environmentally friendly and •
safe to install. All Mule-Hide TPO membranes include OctaGuard XTTM an .
industry leading, state of the art weather package that enables Mule-Hide rf
TPO membranes to withstand the extreme weatherability testing which %`
simulates exposure to severe climates.
BASIC USES
The TPO-c membrane is used in mechanically attached and fully adhered roofing systems in new construction, reroofing and
recover(retrofit)applications. It may also be used as flexible membrane flashings for walls, curbs, etc,when installing TPO-c
membrane roofing systems. The system must be installed over acceptable roof insulation or other suitable substrate. See the
Mule-Hide TPO Specifications Manual for complete specifications and details.
Optional CLEAN Film
Mule-Hide's TPO-c membrane is available with an optional CLEAN Film, a temporary protective film factory applied to the top
surface of the membrane. By protecting the membrane surface from scuffs and dirt accumulation during installation,this
protective film can save labor and time by helping to eliminate the need for roof cleaning upon project completion. CLEAN
Film can be left in place for up to 90 days. Durable and easy to remove, CLEAN Film helps to improve the aesthetics and
long-term reflectivity and is ideal for use on re-roofing, re-cover and new construction projects. CLEAN Film is available on
TPO-c 60 mil membranes supplied in 6'x100'and 10'x 100' rolls.
BENEFITS&SUPPLEMENTAL STATEMENTS
• Wide window of weldability •
• Outstanding puncture resistance
• Chlorine-free with no halogenated flame retardants
• UL 2218 Class 4 hail rating available on select systems
• Excellent low temperature impact resistance
• Excellent chemical resistance to acids, bases, restaurant oils and greases
• Plasticizer-free,does not contain liquid or polymeric plasticizer
• Exceptional resistance to solar UV, ozone and oxidation
• Low water vapor permeance and water absorption
• Hot melt extrusion processed for complete scrim encapsulation
• Non woven reinforcement fabric for smooth surface and greater thickness-over-scrim
• Polyester reinforcing fabric which is resistant to degradation by bacteria, mildew and fungi
• TPO-c is 100%recyclable
• Meets and exceeds requirements of ASTM D6878 Standard Specification for Thermal Plastic Polyolefin
Based Sheet Roofing
• CLEAN Film guards the TPO membrane surface from scuffs and dirt accumulation during installation,
helping to improve the roof systems appearance and maintain long-term reflectivity.
• Clean Film can be left in place for up to 90 days due to its excellent heat and UV resistance.
CODE APPROVALS/COMPLIANCE
A variety of Factory Mutual Ratings and Underwriters Laboratories Classifications are available. Canadian Construction
Materials Centre(CCMC)Evaluation Report 13580-R is also available. Contact Mule-Hide Warranty Department nrcivED
information.
Revised Feb-2018 PDS 09-1105 Pa8e11,c /2 018
/ASPEN
BUILDING DEPARTMENT
Product Data Sheet
MULE-HIDE TPO-c Membrane(Standard, FR &Clean Film)
SPECIFICATIONS
Colors: White, Gray,Tan, Mansard Brown, Patina Green, Rock Brown, Slate Gray&Terra Cotta.
Material: .045-inch and.060-inch(nominal)thick polyester reinforced thermoplastic
Sizes: Field Sheet-8', 10'and 12'by 100'-Perimeter Sheet-4'and 6'by 100'
Weights: 45 Mil-0.23 lb/ft2 (1.1 kg/m2)typical,60 Mil-0.29 lb/ft2 (1.4 kg/m )typical
Physical Properties* Test Method Requirement 45-mil 60-mil
Thickness Tolerance on nominal,% ASTM D-751 +15,-10 ±10 ±10
Thickness over scrim,in.(mm) ASTM D-6878 0.015 min. 0.018 typical 0.024 typical
(avg.of 3 areas) Optical Method (0.380) (0.457) (0.610)
Strength,lbf kN ASTM D-751 220(976 N) 225(1.0)min. 250(1.1)min.
Breaking g ( ) (Grab Method) minimum 320(1.4)typical 360(1.6)typical
ASTM D-751 15 minimum 15 minimum
Elongation at break of fabric,% (Grab Method) 15 minimum 25 typical 25 typical
Tear Strength,lbf(N)8 by 8 in. ASTM D-751 55(245)minimum 55(245)min. 55(245)min.
specimen (B Tongue Tear) 130(578)typical 130(578)typical
-40(-40)maximum -40°F(-40°C)max. -40°F(-40°C)max.
Brittleness point,°F(°C) ASTM D-2137 -50°F(-46)°C typical -50°F(-46°C)typical
Linear Dimensional Change ASTM D-1204 +/-1 max +/-1 max
%chan e 6 hours 158°F(70°C) ±1 maximum -0.2typical -0.2 typical
(shrinkage) 9 @ Yp
Ozone resistance,100 pphm, 168 hrs. ASTM D-1149 PASS PASS PASS
Factory seam strength,lbf/in(kN/m) ASTM D-751 66(290)min 66(290)minimum 66(290)minimum
Field seam strength,lbf/in.(kN/m) ASTM D-1876 No requirement 25(4.4)min. 25(4.4)min.
Seams tested in peel 50(8.8)typical 60(10.5)typical
Water vapor permeance,Perms ASTM E-96 proc.B No requirement 0.10 max. 0.10 max.
0.05 typical 0.05 typical
Water Absorption ASTM D-471 3.0 max. 3.0 max.
No requirement
@ 158°F,166 hours 2.0 typical 2.0 typical
Puncture resistance,lbf(N) FTM 101C No requirement 250(1.1)min. 300(1.3)min.
Method 2031 325(1.4)typical 350(1.6)typical
Properties after heat aging Breaking Strength,%retained 198(881)90%min 205(912)min 225(1000)min
ASTM D573 Elongation reinf.,%retained 13.5(90%)min 13.5 min 13.5 min
670 hrs at 240°F(116°C) Tearing Strength,%retained 33(60%)min 33 min 33 min
Weight change, % ±1.0 max 1.0 max. 1.0 max.
*Typical properties and characteristics are based on samples tested and are not guaranteed for all samples of this product. This data and
information is intended as a guide and does not reflect the specification range for any particular property of this product.
INSTALLATION INSTRUCTIONS
1) Approved insulation shall be attached to the roof deck with an approved insulation adhesive or approved fasteners and
plates. Install insulation with its largest dimension perpendicular to the direction of the membrane seams where possible.
2) Mechanically Attached Roofing System
a) Perimeter sheets to be installed in an approved pattern along all exterior roof edges.
b) Mechanical fasteners and plates are installed in the seams of both the perimeter sheets and field sheets and
into the roof deck. Use approved fasteners and maintain proper penetration for specific roof deck.
3) Fully Adhered Roofing System
a) Perimeter sheets are not required.
b) The membrane is required to be mechanically attached at the base of all vertical surfaces, roof edges,
and angle changes.
c) The field of the roof is fully adhered to the substrate with Mule-Hide TPO Bonding Adhesive.
4) Remove CLEAN Film from areas that are to be heat-welded together. In areas not requiring heat-welding, CLEAN Film
can be lift in place for up to 90 days. Upon completion of the TPO roofing system, remove the CLEAN film and discard.
4) All seams are hot air welded and checked by probing.
5) All details will be done in accordance with Mule-Hide details.
6) On projects where a Mule-Hide Standard or Premium Warranty is requested, an authorized Mule-Hide representative
shall inspect all completed work.This is only a brief summary and not the complete specification. The Mule-Hide
Specifications, Details,Technical Bulletins, and associated documents should be thoroughly reviewed prior to starting any
project. Contact Mule-Hide Products for additional information.
PRECAUTIONS
• Maximum sustained temperature not to exceed 160°F(71°C)for TPO membrane. RECEIVED
• Use proper stacking procedures to ensure roll stability. Avoid creasing the membrane.
Revised Feb-2018 PDS 09-1105 PlY42 V /2 0 18
ASPEN
BUILDING DEPARTMENT
Product Data Sheet
MULE-HIDE TPO-c Membrane(Standard, FR& Clean Film)
PRECAUTIONS (continued)
• Surfaces may be slippery when wet, or due to frost and ice build-up. Exercise caution to prevent falls.
• Mule-Hide TPO membranes are highly reflective to sunlight. Workers should dress appropriately, wear sunscreen,
and wear sunglasses that filter out UV light.
• Exercise care when working near roof edge as edges may not be visible when surrounding area is covered with snow.
• Store Mule-Hide membrane in original wrappings in a cool,shaded area. Cover with light-colored,breathable,
waterproof tarpaulins. Mule-Hide membrane that has been exposed to the elements for approximately 7 days or
longer must be prepared with Weathered Membrane Cleaner prior to hot air welding.
• Do not use razor blades or other sharp tools to cut the CLEAN Film while it is still adhered to the TPO membrane as
damage to the underlying membrane may occur. Pull the protective film away from the membrane prior to cutting.
• Remove CLEAN Film by pulling towards the center of the roof. Do not remove the film by pulling towards the roof
edge.
• A static electricity charge may develop when removing the CLEAN Film from the surface of the membrane sheet. To
avoid the possibility of ignition, lids must be closed on any flammable products and fire extinguishers should be readily
available.
PROTECTION &SAFETY
Mule-Hide maintains Safety Data Sheets on all of its non-exempt products. Safety Data Sheets contain health and safety
information for your development of appropriate product handling procedures to protect your employees and customers. Mule-
Hide's Safety Data Sheets should be read and understood by all of your supervisory personnel and employees before using
Mule-Hide products in your facilities.
SUPPLEMENTAL APPROVALS, STATEMENTS AND CHARACTERISTICS
1) TPO-c meets and exceeds the requirements of ASTM D68781 Standard Specification for Thermoplastic Polyolefin
Based Sheet Roofing
2) TPO-c membranes conform to requirements of the U.S.E.P.A.Toxic Leachate Test(40 CFR part 136)performed by
an independent analytical laboratory
3) TPO-c was tested for dynamic puncture resistance per ASTM D5635-04 using the most recently modified impact
head.45-mil was watertight after an impact energy of 12.5 J(9.2 ft-lbf)and 60-mil was watertight after an impact
energy of 22.5 J(16.6 ft-lbf)
RADIATIVE PROPERTIES for ENERGY STAR*,CRRC and LEED
DESCRIPTION TEST METHOD I WHITE TAN GRAY
TPO-c TPO-c TPO-c
ENERGY STAR®initial solar reflectance Solar Spectrum Reflectometer 0.79 0.71 N/A
ENERGY STAR®initial emissivity 0.90 0.87 N/A
CRRC initial solar reflectance ASTM C1549 0.79 0.71 0.46
CRRC solar reflectance after 3 years ASTM C1549(uncleaned) 0.70 0.64 0.43
CRRC initial thermal emittance ASTM C1371 0.90 0.86 0.89
CRRC thermal emittance after 3 years ASTM C1371 (uncleaned) 0.86 0.87 0.88
CRRC SRI (Solar Reflectance Index) ASTM E1980 99 86 53
CRRC SRI (Solar Reflectance Index after 3 yrs) ASTM E1980 85 77 48
CRRC Product ID N/A 0670-0009 0670-0016 0670-0017
LEEDTM thermal emittance ASTM E408 0.90 0.86 0.53
Mule-Hide Tan and White TPO membranes are ENERGY STARS and California Title 24 rated roof products. Mule-Hide
White TPO membranes are Energy Star compliant.
An ENERGY STAR qualified low slope roof product must have an initial solar reflectance of at least 0.65 and a 3-year aged
solar reflectance of at least 0.50. Cleaning the aged roof surface is not permitted by the ENERGY STAR test protocol.
Energy Star is only valid in the United States for Roofing Products.
The Cool Roof Rating Council(CRRC)does not specify minimums for reflectance or emittance but they do require specific
protocols for testing and reporting. Cleaning of the aged roof surface is not permitted for determination of radiative
properties after 3 years.
A LEED"point"may be earned if a roof material is ENERGY STAR qualified and has a thermal emittance of at A rI���
as determined by ASTM E408.
Revised Feb-2018 PDS 09-1105 •
Paae43� 1 /2 o 18
v ASPEN
BUILDING DEPARTMENT
Product Data Sheet
MULE-HIDE TPO-c Membrane(Standard, FR&Clean Film)
SUPPLEMENTAL APPROVALS, STATEMENTS AND CHARACTERISTICS(continued)
Solar Reflectance Index(SRI) is calculated per ASTM E 1980. The SRI is a measure of the roofs ability to reject solar
heat, as shown by a small temperature rise. It is defined so that a standard black(reflectance 0.05, emittance 0.90)is 0
and a standard white(reflectance 0.80, emittance 0.90)is 100. Materials with the highest SRI values are the coolest
choices for roofing. Due to the way SRI is defined, particularly hot materials can even take slightly negative values, and
particularly cool materials can even exceed 100.
California Title 24 requires an initial minimum reflectance of 0.70 and emittance of 0.75 as determined by CRRC.
RADIATIVE PROPERTIES OF SPECIAL TPO COLORS*
Material Reflectance , Reflectivity Emittance Emissivity SRI** L values*"*
Mansard Brown 0.283 28.3 0.864 86.4 29 32.6
Patina Green 0.248 24.8 0.879 87.9 25 56.7
Rock Brown 0.253 25.3 0.871 87.1 26 53.5
Slate Gray 0.382 38.2 0.867 86.7 42 52.6
Terra Cotta 0.249 24.9 0.861 86.1 25 44.7
*ASTM C 1371-15"Test Method for Determination of Emittance of Materials near Room Temperature Using
Portable Emissometers"—Testing performed by R&D Services on 12/15/2017.
**SRI(Solar Reflectance Index)at Emittance 0.90 per ASTM C1371 (calculated by Gish)
***L Values from color standard index
EXTREME TESTING FOR SEVERE CLIMATES
ASTM Standard D6878 is the material specification for Thermoplastic Polyolefin-Based Sheet Roofing. It covers material
property requirements for TPO roof sheeting and includes initial and aged properties after heat and xenon-arc exposure.
As stated in the standard, "the tests and property limits used to characterize the sheet are values intended to ensure
minimum quality for the intended purpose." Mule-Hide's goal is to provide TPO membranes that exceed the requirements
of ASTM Standard D6878.
,HEAT AGING
Test Method ASTM Requirement Typical Results
ASTM Test-240°F (116°C), No Visible Cracks 32 Weeks 52 Weeks
Test specimen is 1"by 4"piece of 45-mil membrane unbacked,placed in circulating hot-air oven
Criterion-no visible cracks after bending aged test sample around 0.25"diameter mandrel.
Heat Aging accelerates the oxidation rate that roughly doubles for each 10°C(18°F)increase in roof membrane temperature.
Oxidation(reaction with oxygen)is one of the primary chemical degradation mechanisms of roofing materials.
XENON-ARC TESTING
Test Method ASTM D6878 Typical Results Typical Results Typical Results
Requirement 45-mil 60-mil 80-mil
kJ/meat 340 nm 10,080 17,640 20,160 27,720
Test sample is 2.75"by 5.5"piece of membrane,unbacked,weathering side facing arc lamp.
Criterion-no visible cracks viewed under 10x magnification while wrapped around 3"diameter mandrel.
Xenon-Arc exposes the membrane samples to the combined effect of ultraviolet,visible and infrared radiation,ozone,heat and
water spray to greatly accelerate the affects of outdoor weathering. The radiation"dose"is measured in kilojoules per square
meter(kJ/m2)at 340 nm machine UV wavelength. The irradiance"power"of the xenon-arc lamp is measured in Watts per
square meter(W/m2). Test specimen is 2.75 by 5.5 in.piece of membrane,unbacked,weathering side facing lamp. Criteria—
no visible cracks viewed under 10X magnification while wrapped around a 3 in.mandrel.
ENVIRONMENTAL CYCLING
Test Method ASTM Requirement Typical Results
EXTREME Test NONE No cracking under 10x magnification
Test specimen is 2.75"by 5.5"piece of membrane with edges sealed.
- 10 days heat aging at 240°F(116°C)followed by
- 5 days water immersion at 158°F(70°C)followed by
- 5,040 kJ/m2(2000 hours at 0.70 W/m2 irradiance)xenon-arc exposure
Criterion—after 3 completed cycles,test specimens shall remain flexible and not have any cracking under 10x magnifications
while wrapped around a 3"diameter mandrel.
RECEIVED
Revised Feb-2018 PDS 09-1105 I:IV/f,5,/2 018
ASPEN
BUILDING DEPARTMENT
Product Data Sheet
MULE-HIDE TPO-c Membrane(Standard, FR & Clean Film)
ADDITIONAL INFORMATION
The information given on this PDS is subject to change without notice. Always check the Mule-Hide website at
www.mulehide.com for the latest information, changes and updates or contact Mule-Hide Products Company at 800-786-1492.
DISCLAIMER
The statements provided concerning the material shown are intended as a guide for material usage and are believed to be true and accurate
at the time of printing. No statement made by anyone may supersede this information,except when done in writing by Mule-Hide Products
Co.,Inc. Since the manner of use is beyond our control,Mule-Hide does not authorize anyone to make any warranty of merchantability or
fitness for any particular purpose or any other warranty,guarantee or representation,expressed or implied,concerning this material. This
product may be eligible for a Mule-Hide warranty,please check the Mule-Hide website at www.mulehide.com or contact Mule-Hide directly at
800-786-1492 for details. Buyer and user accept the product under these conditions and assume the risk of any failure,any injury person or
property(including that of the user),loss or liability resulting from the handling,storage or use of the product whether or not it is handled,
stored or used in accordance with the directions or specifications. Mule-Hide must be notified in writing of any claims and be given the
opportunity to inspect the alleged failure before repairs are made.
•
RECEIVED
Revised Feb-2018 PDS 09-1105 Pede45/ /2 018
ASPEN