HomeMy WebLinkAboutFile Documents.110 Coach Rd.0079.2018 (35).ARBK REScheck Software Version 4.6.4 u ��
Compliance Certificate RE°1 INIC'1C' E
bonniem
Project Bar X Residence Detached Guest Quarters
Energy Code: 2015 IECC r-OPPOO�L/CFA%.
Location: Aspen, Colorado VO�;•PN•1. ND•.•SF• oIIf
Construction Type: Single-family e :mom 10/19/18l •
Project Type: New Construction e . ,
Conditioned Floor Area: 653 ft2 oe
0 • 39/ •
Glazing Area 51% 19•'• A • • i.
Climate Zone: 7 (9922 HDD) /I)�4`F �•��•.••• �N4
Permit Date: 11,„\oN `e ---
Permit Number:
Construction Site: Owner/Agent: Designer/Contractor:
Coach Road Oyster Shores LLC Jeff McCollum
Aspen, CO 81611 Aspen, CO 81612 Zone 4 Architects
432a E. Hyman Avenue
Aspen, CO 81612
jmccollum@zone4architects.com
Compliance: Passes using UA trade-off
Compliance: 5.4%Better Than Code Maximum UA: 166 Your UA: 157
The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.
Envelope Assemblies
Gross Area Cavity Cont.
Assembly or R-Value R-Value U-Factor UA
Perimeter
Floor Over Crawl:All-Wood Joist/Truss:Over Unconditioned Space 367 38.0 0.0 0.026 10
Lower Level Ceiling to Grade: Cathedral Ceiling 63 49.0 0.0 0.022 1
Flat Roof: Cathedral Ceiling 286 57.0 0.0 0.019 5
Above Grade Wall: Wood Frame, 16" o.c. 316 21.0 0.0 0.057 2
Windows: Wood Frame:Double Pane with Low-E 263 0.320 84
Glass Doors: Glass 24 0.320 8
Above Grade Wall with Concrete Veneer: Wood Frame, 16" o.c. 246 21.0 0.0 0.057 14
Below Grade Furred Wall: Wood Frame 860 13.0 5.0 0.038 33
Wall height: 9.0'
Depth below grade: 9.0'
Insulation depth: 9.0'
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application.The proposed building has been designed to meet the 2015 IECC requirements in
REScheck Version 4.6.4 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
Joshua Westerlind - Mechanical Engineer Wce`A 10/19/18
Name-Title Signature Date
Project Notes: RECEIVED
Project Title: Bar X Residence Detached Guest Quarters Report d2ito/ 11/1O18
Data filename:J:\Jobs\2018 -Jobs\18003.00 - DBX7\Mechanical\Calculations\REScheck\18003-Rescheck Page 1 of10
Detached Guest Quarters.rck ASPEN
BUILDING DEPARTMENT
Calcs By:Joshua Westerlind - Rader Engineering (970)-845-7910
RECEIVED
Project Title: Bar X Residence Detached Guest Quarters Report dzito/n1/1618
Data filename:J:\Jobs\2018 -Jobs\18003.00 - DBX7\Mechanical\Calculations\REScheck\18003-Rescheck Page 2 of10
Detached Guest Quarters.rck ASPEN
BUILDING DEPARTMENT
REScheck Software VersionChecklist 4.6.4
Energy Code: 2015 IECC
Requirements: 0.0% were addressed directly in the REScheck software
Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Section Plans Verified Field Verified
# Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions
& Req.ID
103.1, Construction drawings and '❑Complies
103.2 documentation demonstrate Does Not
[PR1]1 energy code compliance for the
,,: building envelope.Thermal ❑Not Observable
envelope represented on ❑Not Applicable
construction documents.
103.1, Construction drawings and ❑Complies
103.2, documentation demonstrate ❑Does Not
403.7 energy code compliance for
[PR3]1 lighting and mechanical systems. ['Not Observable
g, Systems serving multiple ENot Applicable
dwelling units must demonstrate
compliance with the IECC
Commercial Provisions.
302.1, Heating and cooling equipment is' Heating: Heating: ❑Complies 1
403.7 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not
[PR2]2 on loads calculated per ACCA Cooling: Cooling:
H, Manual J or other methods ['Not Observable
Btu/hr Btu/hr
'approved by the code official. ❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) RECEIVED
Project Title: Bar X Residence Detached Guest Quarters Report dgto/n/1/1 .O18
Data filename:J:\Jobs\2018 -Jobs\18003.00 - DBX7\Mechanical\Calculations\REScheck\18003-Rescheck Page 3 of10
Detached Guest Quarters.rck ASPEN
BUILDING DEPARTMENT
Section Plans Verified Field Verified
# Foundation Inspection Value Value Complies? Comments/Assumptions
& Req.ID
402.1.1 Conditioned basement wall R- R- ❑Complies See the Envelope Assemblies
[FO4]1 insulation R-value. Where interior R- R- ❑Does Not table for values.
insulation is used, verification
may need to occur during [Not Observable
Insulation Inspection. Not ENot Applicable
required in warm-humid locations
in Climate Zone 3.
303.2 Conditioned basement wall ❑Complies
[FO5]1 insulation installed per ❑Does Not
6 manufacturer's instructions. [Not Observable
❑Not Applicable
402.2.9 Conditioned basement wall ft ft ❑Complies See the Envelope Assemblies
[FO6]1 insulation depth of burial or ❑Does Not table for values.
t distance from top of wall.
[Not Observable
❑Not Applicable
303.2.1 ;A protective covering is installed ❑Complies
[FO11]2 to protect exposed exterior ❑Does Not
insulation and extends a
minimum of 6 in. below grade. ❑Not Observable
❑Not Applicable
403.9 Snow-and ice-melting system ❑Complies
[FO12] controls installed. ❑Does Not
.44 ❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 I High Impact(Tier 1) 1 2_Medium Impact(Tier 2) 3 Low Impact(Tier 3) j RECEIVED
Project Title: Bar X Residence Detached Guest Quarters Report dzitrJ/n/1$21O18
Data filename: J:\Jobs\2018 -Jobs\18003.00 - DBX7\Mechanical\Calculations\REScheck\18003-Rescheck Page 4 of10
Detached Guest Quarters.rck ASPEN
BUILDING DEPARTMENT
Section Plans Verified Field Verified
# Framing / Rough-In Inspection Value Value Complies? Comments/Assumptions
& Req.ID
402.1.1, Glazing U-factor(area-weighted U- U- ❑Complies See the Envelope Assemblies
402.3.1, average). El Does Not table for values.
402.3.3,
402.3.6, [Not Observable
402.5 ENot Applicable
[FR2]1
303.1.3 U-factors of fenestration products ❑Complies
[FR4]1 are determined in accordance ❑Does Not
with the NFRC test procedure or ['Not Observable
taken from the default table.
ENot Applicable
402.4.1.1 ;Air barrier and thermal barrier ❑Complies
[FR23]1 installed per manufacturer's ❑Does Not
instructions. ['Not Observable
❑Not Applicable
402.4.3 Fenestration that is not site built ❑Complies
[FR20]1 is listed and labeled as meeting , ❑Does Not
AAMA/WDMA/CSA 101/I.S.2/A440
or has infiltration rates per NFRC ['Not Observable
400 that do not exceed code ENot Applicable
limits.
402.4.5 :IC-rated recessed lighting fixtures ❑Complies
[FR16]z (sealed at housing/interior finish ❑Does Not
:and labeled to indicate <_2.0 cfm
;leakage at 75 Pa. [Not Observable
❑Not Applicable
403.2.1 Supply and return ducts in attics ❑Complies
[FR12]1 insulated >= R-8 where duct is ❑Does Not
>= 3 inches in diameter and >=
R-6 where < 3 inches. Supply and [Not Observable
return ducts in other portions of ENot Applicable
the building insulated >= R-6 for
diameter>= 3 inches and R-4.2
for< 3 inches in diameter.
403.3.3.5 Building cavities are not used as ❑Complies
[FR15]3 ducts or plenums. ❑Does Not
l)'
[Not Observable
❑Not Applicable
403.4 'HVAC piping conveying fluids R- R- EComplies
[FR17]z above 105 °F or chilled fluids EDoes Not
below 55 °F are insulated to 1:(-
3. [Not Observable
❑Not Applicable
403.4.1 :Protection of insulation on HVAC ❑Complies
[FR24]1 :piping. ❑Does Not
d' [Not Observable
ENot Applicable
403.5.3 Hot water pipes are insulated to R- R- ❑Complies
[FR18]z >_R-3. ❑Does Not
[Not Observable
❑Not Applicable
403.6 Automatic or gravity dampers are ❑Complies
[FR19]z installed on all outdoor air ❑Does Not
intakes and exhausts.
[Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 I High Impact(Tier 1) 12_Medium Impact(Tier 2) 3 Low Impact(Tier 3) J RECEIVED
Project Title: Bar X Residence Detached Guest Quarters Report dzitrJ/n/1i921O18
Data filename: J:\Jobs\2018 -Jobs\18003.00 - DBX7\Mechanical\Calculations\REScheck\18003-Rescheck Page 5 of10
Detached Guest Quarters.rck ASPEN
BUILDING DEPARTMENT
1 I High Impact(Tier 1) 2_Medium Impact(Tier 2) 3 Low Impact(Tier 3) J RECEIVED
Project Title: Bar X Residence Detached Guest Quarters Report dzitrJ/n/11921O18
Data filename: J:\Jobs\2018 -Jobs\18003.00 - DBX7\Mechanical\Calculations\REScheck\18003-Rescheck Page 6 of10
Detached Guest Quarters.rck ASPEN
BUILDING DEPARTMENT
Section Plans Verified Field Verified
# Insulation Inspection Value Value Complies? Comments/Assumptions
& Req.ID
303.1 ;All installed insulation is labeled '❑Complies
•
[IN13]2 or the installed R-values ❑Does Not
provided. Ilir [Not Observable
❑Not Applicable
402.1.1, Floor insulation R-value. R- R- ❑Complies See the Envelope Assemblies
402.2.6 ❑ Wood ❑ Woo-d ❑Does Not table for values.
['Nip ❑ Steel ❑ Steel [Not Observable
tio
❑Not Applicable
303.2, Floor insulation installed per ❑Complies
402.2.7 manufacturer's instructions and ❑Does Not
[IN2]1 in substantial contact with the
CO underside of the subfloor, or floor ['Not Observable
framing cavity insulation is in ❑Not Applicable
contact with the top side of
sheathing, or continuous
insulation is installed on the
underside of floor framing and
extends from the bottom to the
top of all perimeter floor framing
members.
402.1.1, Wall insulation R-value. If this is a R- R- EComplies See the Envelope Assemblies
402.2.5, mass wall with at least 1/2 of the ❑ Wood ❑ Woo-d ❑Does Not table for values.
402.2.6 wall insulation on the wall ❑ Mass ❑ Mass ['Not Observable
[IN3]1 exterior,the exterior insulation
requirement applies(FR10). ❑ Steel ❑ Steel ❑Not Applicable
303.2 Wall insulation is installed per ❑Complies
[IN4]1 manufacturer's instructions. ❑Does Not
[Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 I High Impact(Tier 1) 1 2_Medium Impact(Tier 2) 3 Low Impact(Tier 3) j RECEIVED
Project Title: Bar X Residence Detached Guest Quarters Report dzitrJ/ /1/921O18
Data filename: J:\Jobs\2018 -Jobs\18003.00 - DBX7\Mechanical\Calculations\REScheck\18003-Rescheck Page 7 of10
Detached Guest Quarters.rck ASPEN
BUILDING DEPARTMENT
Section Plans Verified Field Verified
# Final Inspection Provisions Value Value Complies? Comments/Assumptions
& Req.ID_
402.1.1, Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies
402.2.1, ❑ Wood ❑ Wood ❑Does Not table for values.
402.2.2, j ❑ Steel ❑ Steel [Not Observable
402.2.6
[FI1]1 ENot Applicable
303.1.1.1, Ceiling insulation installed per ❑Complies
303.2 manufacturer's instructions. ❑Does Not
[F12]1 Blown insulation marked every
300 ft2. [Not Observable
ENot Applicable
402.2.3 !Vented attics with air permeable EComplies
[F122]2 insulation include baffle adjacent ❑Does Not
to soffit and eave vents that
;extends over insulation. [Not Observable
, ❑Not Applicable
402.2.4 Attic access hatch and door R- R- EComplies
[F13]1 insulation >_R-value of the ❑Does Not
adjacent assembly.
[Not Observable
❑Not Applicable
402.4.1.2 :Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 = EComplies
[F117]1 ach in Climate Zones 1-2, and ❑Does Not
,<=3 ach in Climate Zones 3-8.
ENot Observable
ENot Applicable
403.2.3 Duct tightness test result of<=4 cfm/100 cfm/100 EComplies
[F14]1 cfm/100 ft2 across the system or ft2 ft2 ❑Does Not
<=3 cfm/100 ft2 without air
handler @ 25 Pa. For rough-in ['Not Observable
tests,verification may need to ENot Applicable
occur during Framing Inspection.
403.3.2 Ducts are pressure tested to cfm/100 cfm/100 EComplies
[F127]1 determine air leakage with ft2 ft2 Does Not
either: Rough-in test:Total
leakage measured with a ['Not Observable
pressure differential of 0.1 inch ENot Applicable
w.g. across the system including
the manufacturer's air handler
enclosure if installed at time of
test. Postconstruction test:Total
leakage measured with a
pressure differential of 0.1 inch
w.g. across the entire system
including the manufacturer's air
handler enclosure.
403.3.2.1 Air handler leakage designated EComplies
[F124]1 by manufacturer at<=2%of ❑Does Not
design air flow.
[Not Observable
ENot Applicable
403.1.1 :Programmable thermostats EComplies
[F19]2 I installed for control of primary ❑Does Not
j heating and cooling systems and
:initially set by manufacturer to ['Not Observable
:code specifications. ❑Not Applicable
i
403.1.2 Heat pump thermostat installed ❑Complies
[F110]2 on heat pumps. ❑Does Not
ENot Observable
❑Not Applicable
403.5. Circulating service hot water ❑Complies
[F111]z systems have automatic or EDoes Not
accessible manual controls.
['Not Observable
i ENot Applicable
1 I High Impact(Tier 1) 12_Medium Impact(Tier 2) 3 Low Impact(Tier 3) j RECEIV D
Project Title: Bar X Residence Detached Guest Quarters Report dzitrJ/n/1/1 .O18
Data filename: J:\Jobs\2018 -Jobs\18003.00 - DBX7\Mechanical\Calculations\REScheck\18003-Rescheck Page 8 of10
Detached Guest Quarters.rck ASPEN
BUILDING DEPARTMENT
Section Plans Verified Field Verified
# Final Inspection Provisions Value Value Complies? Comments/Assumptions
& Req.ID
403.6.1 ;All mechanical ventilation system ' •Complies
[F125]z fans not part of tested and listed0
•Does Not
HVAC equipment meet efficacy
and air flow limits. •Not Observable
403.2 ;Hot water boilers supplying heat ❑Complies
[F126]z through one-or two-pipe heatingail
❑Does Not
systems have outdoor setback
control to lower boiler water ❑Not Observable
temperature based on outdoor ❑Not Applicable
j temperature.
403.5.1.1 Heated water circulation systems ❑Complies
[F128]2 have a circulation pump.The ❑Does Not
system return pipe is a dedicated
return pipe or a cold water supply ❑Not Observable
pipe. Gravity and thermos- ENot Applicable
syphon circulation systems are
not present. Controls for
circulating hot water system
pumps start the pump with signal
for hot water demand within the
'occupancy. Controls
41 automatically turn off the pump
when water is in circulation loop
is at set-point temperature and
no demand for hot water exists.
403.5.1.2 'Electric heat trace systems ❑Complies
[F129]z comply with IEEE 515.1 or UL El Does Not
515. Controls automatically
adjust the energy input to the ['Not Observable
heat tracing to maintain the ❑Not Applicable
desired water temperature in the
:piping.
403.5.2 Water distribution systems that 1 ❑Complies
[F130]z have recirculation pumps that EDoes Not
pump water from a heated water
supply pipe back to the heated ['Not Observable
water source through a cold ❑Not Applicable
water supply pipe have a
demand recirculation water
system. Pumps have controls
that manage operation of the
pump and limit the temperature
of the water entering the cold
:water piping to 104°F.
403.5.4 Drain water heat recovery units ❑Complies
[F131]z tested in accordance with CSA ❑Does Not
B55.1. Potable water-side
pressure loss of drain water heat ❑Not Observable
recovery units < 3 psi for ❑Not Applicable
individual units connected to one
or two showers. Potable water-
side pressure loss of drain water
heat recovery units < 2 psi for
individual units connected to
three or more showers.
404.1 75%of lamps in permanent ❑Complies
[F16]1 fixtures or 75%of permanent EDoes Not
fixtures have high efficacy lamps.
Does not apply to low-voltage ❑Not Observable
lighting. ❑Not Applicable
404.1.1 Fuel gas lighting systems have ❑Complies
[F123]3 no continuous pilot light. EDoes Not
J 111 ❑Not Observable
❑Not Applicable
1 I High Impact(Tier 1) 1 2_Medium Impact(Tier 2) 3 Low Impact(Tier 3) j RECEIVED
Project Title: Bar X Residence Detached Guest Quarters Report dzitrJ/n/1/1 .O18
Data filename: J:\Jobs\2018 -Jobs\18003.00 - DBX7\Mechanical\Calculations\REScheck\18003-Rescheck Page 9 of10
Detached Guest Quarters.rck ASPEN
BUILDING DEPARTMENT
Section Plans Verified Field Verified
# Final Inspection Provisions Value Value Complies? Comments/Assumptions
& Req.ID
401.3 Compliance certificate posted. '❑Complies
[F17]2 ❑Does Not
[Not Observable
❑Not Applicable
303.3 Manufacturer manuals for EComplies
[F118]3 mechanical and water heating ❑Does Not
systems have been provided.
[Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) RECEIVED
Project Title: Bar X Residence Detached Guest Quarters Report dgto/n/1)921O18
Data filename:J:\Jobs\2018 -Jobs\18003.00 - DBX7\Mechanical\Calculations\REScheck\18003-Rescheck Page 10 of10
Detached Guest Quarters.rck ASPEN
BUILDING DEPARTMENT
Li( 2015 IECC Energy
Efficiency Certificate
Insulation Ratin. R-Value
Above-Grade Wall 21.00
Below-Grade Wall 18.00
Floor 38.00
Ceiling / Roof 57.00
Ductwork (unconditioned spaces):
Glass& Door Rating U-Factor SHGC
Window 0.32
Door 0.32
Heating&Cooling Equipment Efficiency
Heating System:
Cooling System:
Water Heater:
Name: Date:
Comments
RECEIVED
10/30/2018
ASPEN
BUILDING DEPARTMENT