HomeMy WebLinkAboutFile Documents.520 W Hallam St.0150.2018 (6).ARBK 10/22/2014 TGFU.R15546-Roofing Systems
(113 ONLINE CERTIFICATIONS DIRECTORY
TGFU.R15546
Roofing Systems
Page Bottom
Roofing Systems
See General Information for Roofing Systems
IB ROOF SYSTEMS R15546
SUITE 150
8181 JETSTAR DR
IRVING, TX 75063 USA
Noncombustible roof deck classifications are applicable for use over combustible roof (minimum 15/32-in. thick) decks when
minimum 1/2-in.thick gypsum board or minimum 1/4-in. thick G-P Gypsum Corp. "DensDeck ® Roofboard" or"DensDeck Prime®
Roofboard" or"DensDeck Prime 2'"' Roofboard" or"DensDeck DuraGuard® Roofboard" or Certainteed Gypsum Inc"GlasRoc" or
USG Corp. SECUROCK® Glass-Mat Roof Board (Type SGMRX)" are used directly over the plywood roof deck with all butt joints in
the barrier board staggered a minimum of 6-in. from plywood roof deck butt joints.
Any system listed for use over a combustible deck can be installed over a non-combustible deck and achieve the same
classification.
Uniform thickness or tapered insulation may be used in the following systems provided they do not exceed the indicated incline or
thickness.
Unless otherwise indicated the insulation may be mechanically attached, adhered with any UL Classified adhesive or hot mopped.
Any UL Classified Insulation may be used below a minimum 1/2-in.thick gypsum board or minimum 1/4-in. thick G-P Gypsum
Corp. "DensDeck ® Roofboard" or"DensDeck Prime® Roofboard" or"DensDeck Prime 2"" Roofboard" or"DensDeck DuraGuard®
Roofboard" or Certainteed Gypsum Inc"GlasRoc" or USG Corp. SECUROCK® Glass-Mat Roof Board (Type SGMRX)".
SINGLE PLY MEMBRANE SYSTEMS
"IB" (CPA) is produced 40 to 80 mil thickness.
For non-combustible deck applications one of the following insulation attachments may be used. (1) mechanically fastened (2) hot
mopping asphalt(3) "Instastick" deck adhesive (4) Ashland "Pliodeck" adhesive in accordance with the manufacturers
recommendations.
Class A -Ballast
1. Deck: C-15/32 Incline: 2
Insulation:—Any UL Classified insulation, any thickness.
Membrane:— "IB" (CPA) or IB Single Ply.
Surfacing:— River bottom stone (3/4 to 1-1/2 in. diam) at 1000 lbs/sq.
Class A-Fully Adhered
1. Deck: NC Incline: 2
Insulation:—Any UL Classified HD wood fiber board, "IB Energy Board II", Atlas Roofing "ACFoam II" Firestone Building
Products "Iso 95+GL" or"Iso 95+GW", Johns Manville "ENRGY 2A", Rmax "Multi-Max", any thickness, mechanically attached
or hot mopped.
Membrane:— "IB" (CPA), adhered with Ashland Chemical "Pliobond 7500" bonding adhesive, at 1 gal/160 sq ft. The
overlapping membrane joints are heat sealed.
2. Deck: NC Incline: 2
Insulation:— "IB Energy Board II" or"IB Energy Board III", Johns Manville "ENRGY 2", Atlas Roofing "ACFoam II",
"ACFoam III", Firestone Building Products "ISO 95+GL", any thickness.
Membrane:— "IB" (CPA), adhered with "IB Contact Adhesive" at 60 sq/ft/gal.
3. Deck: NC Incline: 2
Insulation:—Any UL Classified EPS Composite (EPS/perlite, perlite side up or EPS/wood fiber, wood fiber side, �n
thickness, / 1
IvEr
Barrier Board(Optional):— 1/4 in. (min) G-P Gypsum DensDeck ®, DensDeck Prime®, USG SECUROCK Glasg §t-R iM' 1
Board, CertainTeed Gypsum GlasRoc or 1/2-in Gypsum Board with all joints staggered 6 in. from the plywood joints,
mechanically attached or adhered. Q,525/2018
Membrane:— "IB" (CPA), adhered with Ashland Chemical "Pliobond 7500" bonding adhesive, at 1 gal/160 sq ft
ro
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1F RAM E/showpage.html?name=TGFU.R15546&ccnshorttitle=Roofing+Systems&objid=1074352016&cf pe
L
BUILDING DEPARTMENT
10/22/2014 TGFU.R 15546-Roofing Systems
Contact Adhesive" at 1 gal/60 sq ft. The overlapping joints are heat-sealed.
4. Deck: C-15/32 Incline: Unlimited Impact: 4
Insulation:— Any UL Classified insulation, any thickness:
Barrier Board:— 1/4 in. min G-P Gypsum DensDeck®, DensDeck Prime®, USG SECUROCK Glass-Mat Roof Board,
CertainTeed Gypsum GlasRoc or 1/2-in Gypsum Board with all joints staggered 6 in. from the plywood joints, mechanically
attached or adhered.
Membrane:— "IB" (CPA) adhered with TACC "LA 432" adhesive at 1 gal/60 sq ft or"FA 636" adhesive at 1 gal/140 sq ft.
5. Deck: NC Incline: 1
Insulation:— One of the following, any thickness:
1. Firestone Building Products "ISO 95+GL"
2. Johns Manville "ENRGY 3"
Membrane:— "IB Single Ply®", adhered with TACC "LA 432" adhesive at 1 gal/60 sq ft or"FA 636" adhesive at 1
gal/140 sq ft.
6. Deck: C-15/32 Incline: Unlimited Impact: 4
Insulation:—Any UL Classified insulation, any thickness:
Barrier Board:— 1/4 in. min G-P Gypsum DensDeck®, DensDeck Prime®, USG SECUROCK Glass-Mat Roof Board,
CertainTeed Gypsum GlasRoc or 1/2-in Gypsum Board with all joints staggered 6 in. from the plywood joints,
mechanically attached or adhered.
Membrane: — "IB Single Ply®", adhered with TACC "LA 432" adhesive at 1 gal/60 sq ft or"FA 636" adhesive at 1
gal/140 sq ft.
7. Deck: NC Incline: 1-1/2
Insulation: — One of the following, any thickness:
1. Atlas Roofing "ACFoam II"
2. Atlas Roofing "ACFoam III"
3. "IB Energy Board II"
4. "IB Energy Board III"
Membrane:— "IB Single Ply®", adhered with TACC "LA 432", "LA432M" or Ashland "7008" adhesive at 1
gal/60 sq ft.
8. Deck: C-15/32 Incline: Unlimited
Vapor Barrier(Optional):— Polyethylene, Kraft or Soprema Inc. "SopraVap'r", self-adhered.
Insulation: — "IB Energy Board II", "IB Energy Board III", Atlas Roofing Corp. "ACFoam II", "ACFoam III" or
"CoverBoard HS", any thickness mechanically attached or adhered with any UL Classified adhesive.
Barrier Board:— Minimum 1/4-in. thick Georgia-Pacific Gypsum LLC "DensDeck ® Roofboard" or"DensDeck
Prime® Roofboard" or"DensDeck Prime 2"" Roofboard" or"DensDeck DuraGuard® Roofboard" or
Certainteed Gypsum Inc "GlasRoc" or USG Corp. "SECUROCK® Glass-Mat Roof Board (Type SGMRX)", loose
laid, mechanically fastened or adhered with any UL Classified insulation adhesive with all butt joints in the
barrier board staggered a minimum of 6-in. from the plywood roof deck butt joints.
Membrane:— "IB PVC-GR 60" and "IB PVC-GR 60FB", adhered with Ashland Inc. "Pliobond 7008" at 0.625
gal/sq. (160 ft2/gal) or"Pliobond 1746" at 1.67 gal/sq. (60 ft2/gal).
9. Deck: NC Incline: 3
Vapor Barrier(Optional):— Polyethylene, Kraft or Soprema Inc. "SopraVap'r", self-adhered.
Insulation:— "IB Energy Board II", "IB Energy Board III", Atlas Roofing Corp. "ACFoam II", "ACFoam III" or
"CoverBoard HS", any thickness mechanically attached or adhered with any UL Classified adhesive.
Barrier Board(Optional):— Minimum 1/4-in. thick Georgia-Pacific Gypsum LLC "DensDeck ® Roofboard" or
"DensDeck Prime® Roofboard" or"DensDeck Prime 2'" Roofboard" or"DensDeck DuraGuard® Roofboard" or
Certainteed Gypsum Inc "GlasRoc" or USG Corp. "SECUROCK® Glass-Mat Roof Board (Type SGMRX)", loose
laid, mechanically fastened or adhered with any UL Classified insulation adhesive with all butt joints in the
barrier board staggered a minimum of 6-in. from the plywood roof deck butt joints.
Membrane: — "IB PVC-GR 60" and "IB PVC-GR 60FB", adhered with Ashland Inc. "Pliobond 7008" at 0.625
gal/sq. (160 ft2/gal) or"Pliobond 1746" at 1.67 gal/sq. (60 ft2/gal).
Class A-Mechanically Fastened
1. Deck: NC Incline: 2
Insulation:— Glass fiber, Johns Manville "Fesco-Foam", perlite or HD Wood fiber Board, 3/4 to 4 in.
Membrane:— "IB" (CPA). e F
2. Deck: NC Incline: 2 j $r, {q�tir
Insulating Concretes:— Cellular, gypsum vermiculite, perlite or structural, poured in place over de,ekr 2 2
Membrane:— "IB" (CPA). u � r5� 018
http://database.ul.com/cg i-bi n/XYV/template/LISEXT/1 FRAM E/showpag e.html?name=TGFU.R 15546&ccnshorttitle=Roofing+Systems&obj id=1074352016&cfgAspn
BUILDING DEPARTMENT
10/22/2014 TGFU.R15546-Roofing Systems
3. Deck: NC Incline: 2
Insulation:—Any UL Classified polystyrene, any thickness.
Slip Sheet:—Atlas Roofing "FR-50" or"IB Fire Sheet 50".
Membrane:— "IB" (CPA).
4. Deck: NC Incline: 2
Slip Sheet(Optional):—Atlas Roofing "FR-10 " or"IB Fire Sheet 10".
Insulation:— "IB Energy Board II", Atlas Roofing "ACFoam II" or"ACFoam Supreme", any thickness, hot
mopped in place or mechanically fastened.
Membrane:— "IB" (CPA).
5. Deck: NC Incline: 1
Insulation:— Any UL Classified polystyrene, any thickness.
Slip Sheet:—Atlas Roofing "FR-10" or"IB Fire Sheet 10".
Membrane:— "IB" (CPA).
6. Deck: NC Incline: 3
Insulation:—Atlas Roofing "ACFoam II" or"ACF III", "IB Energy Board II", "IB Energy Board III", Firestone
Building Products "ISO 95+GL" or"ISO 95+GW", Johns Manville "ENRGY 2A", Rmax "Multi-Max", any
thickness.
Membrane: — "IB" (CPA).
7. Deck: C-15/32 Incline: 3
Barrier Board:— 1/4 in. (min) G-P Gypsum DensDeck ®, DensDeck Prime®, USG SECUROCK Glass-Mat Roof
Board, CertainTeed Gypsum GlasRoc or 1/2 in. (min) gypsum board with all joints staggered a min of 6 in.
from the plywood joints.
Insulation:—Atlas Roofing "ACFoam II" or"ACF III", "IB Energy Board II", "IB Energy Boardlll", Firestone
Building Products "ISO 95+GL" or"ISO 95+GW", Johns Manville "ENRGY 2A", Rmax "Multi-Max", or
"Thermaroof Plus", any thickness.
Membrane:— "IB" (CPA).
8. Deck: C-15/32 Incline: Unlimited
Insulation(Optional):— Any UL Classified, any thickness.
Barrier Board:— 1/4 in. (min) G-P Gypsum DensDeck®, DensDeck Prime®, USG SECUROCK Glass-Mat Roof
Board, CertainTeed Gypsum GlasRoc or 1-in Gypsum Board with all joints staggered a min of 6 in. from the
plywood joints.
Membrane:— "IB" (CPA) or"IB Single Ply".
9. Deck: C-15/32 Incline: 1/2
Slip Sheet:—Two layers Atlas Roofing "FR-50" or"IB Single Ply".
Membrane:— "IB" (CPA) or"IB Single Ply".
10. Deck: NC Incline: 1
Insulation:— Owens Corning Specialty Products "Foamular", any thickness.
Slip Sheet:—Atlas Roofing. "FR-10" or"FR-50","IB Fire Sheet 10" or"IB Fire Sheet 50".
Membrane:— "IB" (CPA).
11. Deck: C-15/32 Incline: 1/2
Slip Sheet:— One layer Atlas Roofing "FR-10", or"FR-50", "IB Fire Sheet 10" or"IB Fire Sheet 50".
Insulation:— "IB Energy Board III" or Atlas Roofing "ACFoam III", 1.5 in. min thickness with all joints
staggered 6 in. min. from plywood joints.
Membrane:— "IB" (CPA).
12. Deck: NC Incline: 3
Insulation:—
1. Firestone Building Products "ISO 95+GL"
2. Johns Manville "ENRGY 2"
3. Rmax "Multi-Max FA"
4. Atlas Roofing "ACFoam II"
5. Atlas Roofing "ACFoam III"
6. Johns Manville "ISO 1" F/ qFF} \
7. "IB Energy Board II"
° • ,;)
8. "IB Energy Board III" 05/25/2018
http://database.ul.com/cg i-bi n/XYV/template/LISEXT/1 FRAM E/showpag e.html?name=TGFU.R 15546&ccnshorttitle=Roofing+Systems&objid=1074352016&cfgAS PEN
BUILDING DEPARTMENT
10/22/2014 TGFU.R15546-Roofing Systems
Membrane:- "IB" (CPA).
13. Deck: C-15/32 Incline: 1/2
Slip Sheet:-Two layers Atlas Roofing "FR-50".
Insulation:- 1.5 in. min with all joints staggered 6 in. (min) from the plywood joints.
1. Firestone Building Products "ISO 95+GL"
2. Johns Manville "ENRGY-2"
3. Rmax "Multi-Max FA"
4. Atlas Roofing "ACFoam II"
5. Atlas Roofing "ACFoam III"
6. Johns Manville "ISO 1"
7. "IB Energy Board II"
8. "IB Energy Board III"
Membrane: - "IB" (CPA).
14. Deck: C-15/32 Incline: 1/2
Slip Sheet:-Two layers Atlas Roofing "FR-50" or"IB Fire Sheet 50".
Membrane:- "IB" (CPA).
15. Deck: C-15/32 Incline: 1/2
Slip Sheet: - One layer Atlas Roofing "FR-10" or"FR-50".
Insulation:- "ACFoam III" or"IB Energy Board III", 1.5 in. min thickness with all joints staggered 6 in. min
from the plywood joints.
Membrane:- "IB" (CPA) or"IB Single Ply".
16. Deck: C-15/32 Incline: 3/4, See Note
Slip Sheet:-Two layers "FR-10," IB Fire Sheet 10 mechanically fastened.
Insulation(Optional):- Any UL Classified, any thickness (except EPS and wood fiberboard).
Membrane:-Any UL Classified PVC, CPE, CSM, CSPE, EPDM, NBP, PIB, TPO, EIP orTRE membrane. (Note:
Membrane must be currently Classified for use over the insulation used. Actual incline is determined by the
maximum existing membrane/insulation Classification incline.)
17. Deck: C-15/32 Incline: 1-1/2
Slip Sheet:-Two layers GAF "VersaShield Underlayment" or"IB Fire Sheet- 2".
Membrane: - "IB" (CPA).
18. Deck: C-15/32 Incline: 2
Slip Sheet:-Two layers GAF "VersaShield Underlayment".
Insulation: - Firestone Building Products "ISO 95+GL" or"ISO 95+GW", Johns Manville "ENRGY 2A", Rmax
"Multi-Max", any thickness.
Membrane: - "IB" (CPA).
19. Deck: C-15/32 Incline: 2
Slip Sheet: - : Two layers GAF "VersaShield Underlayment".
Insulation(Optional):-
1. Firestone Building Products "ISO 95+GL"
2. Johns Manville "ENRGY 2"
3. Rmax "Multi-Max FA"
4. Atlas Roofing "ACFoam II"
5. Atlas Roofing "ACFoam III"
6. Johns Manville "ISO 1"
7. "IB Energy Board II"
8. "IB Energy Board III"
Membrane:- "IB" (CPA).
6
20. Deck: C-15/32 Incline: 1/2 RECEIVE
Slip Sheet:-Two layers Atlas Roofing "FR 50" or"IB Fire Sheet 50". 05/25/2018
Insulation:- 1.5 in. min. with all joints staggered 6 in. (min.) from the plywood joints
http://database.ul.conn/cgi-bir>/XYV/template/LISFXr/1FRAME/showpage.htn1l?name=TGFU.R15546&ccnshorttitle=Roofing+Systems&objid=1074352016&cfg .sp4