Loading...
HomeMy WebLinkAboutFile Documents.303 E Main St.0046.2018 (6).ACBK UL Evaluation Report UL ER10167-01 Issued: July 25, 2014 Visit UL's On-Line Certifications Directory:www.ul.com/erdirectory for current status of Report. UL Category Code: ULFB CSI MasterFormat® DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION Sub-level 2: 07 50 00 — Membrane Roofing Sub-level 3: 07 54 00 —Thermoplastic Membrane Roofing Sub-level 4: 07 54.23—Thermoplastic-Polyolefin Roofing COMPANY: Johns Manville 717 17th Street Denver, CO 80202-3330 http://www.jm.com/ 1. SUBJECT: JM TPO 45, JM TPO 60, JM TPO 72, JM TPO 80 JM TPO Reflexsa JM TPO FB 115, JM TPO FB 135 2. SCOPE OF EVALUATION ■2012, 2009 and 2006 International Building Code®(IBC) ■2012, 2009 and 2006 International Residential Code®(IRC) • ICC ES Acceptance Criteria for Roof-Covering Systems (AC75), Dated July 2010 • ICC ES Acceptance Criteria for Quality Documentation (AC10), Dated December 2012 Page 1 of 34 RECEIVED 04/23/2018 ASPEN BUILDING DEPARTMENT The products were evaluated for the following properties: ■Roofing Systems for Exterior Fire Exposure (ANSI/UL 790, ASTM E108) ■Roofing Systems, Wind Uplift Resistance (FM 4474) ■Physical Properties (ASTM D6878, ASTM G155) ■Impact Resistance (FM 4470) ■Foot Traffic Resistance (FM 4470) 3. REFERENCED DOCUMENTS ■ ANSI/UL 790 (ASTM E108), Standard Test Methods for Fire Tests of Roof Coverings ■ FM 4474, Evaluating the Simulated Wind Uplift Resistance of Roof Assemblies Using Static Positive and/or Negative Differential Pressures ■ ASTM D6878 Standard Specification for Thermoplastic Polyolefin Based Sheet Roofing ■ ASTM G155, Standard Practice for Operating Xenon Arc Light Apparatus for Exposure of Non- Metallic Materials ■ FM 4470, Single-Ply, Polymer-Modified Bitumen Sheet, Built-Up Roof (BUR) and Liquid Applied Roof Assemblies for use in Class 1 and Noncombustible Roof Deck Construction ■ FM 4474, Evaluating the Simulated Wind Uplift Resistance of Roof Assemblies Using Static Positive and/or Negative Differential Pressures ■ ICC ES Acceptance Criteria for Membrane Roof-Covering Systems (AC75), Dated July 2010 ■ ICC ES Acceptance Criteria for Quality Documentation (AC10), Dated December 2012 4. USES The JM TPO, JM TPO FB and JM TPO Reflexsa single-ply roof membranes are used as roof coverings in mechanically fastened or fully adhered Class A, B or C roof assemblies installed on combustible or non- combustible roof decks. 5. PRODUCT DESCRIPTION The JM TPO, JM TPO FB and JM TPO Reflexsa membrane roofing systems described in this report consist of single-ply roofing membranes, insulation where used, barrier board or slip sheet where used, flashing, mechanical fasteners and adhesives that are installed on a combustible or non-combustible roof deck. The roofing assemblies incorporating the membranes comply with the following properties when installed as described in this report. Fire Classification: Roofing assemblies covered under this report have been tested for fire classification Class A, B or C in accordance with ANSI/UL790 or(ASTM E108), as required by Section 1505.1 of 2012, 2009 and 2006 IBC and Section R902.1 of the 2012, 2009 and 2006 IRC. Wind Uplift Resistance: Roofing assemblies covered under this report have been tested for wind uplift resistance in accordance with FM 4474, and therefor qualify for use under Roofing membranes Section 1504.3.1 of the 2012, 2009 and 2006 IBC. RECEIVED Page2of34 04/23/2018 ASPEN BUILDING DEPARTMENT The roofing assemblies shall be designed to resist the design wind load pressures for components and cladding in accordance with Section 1609 of the 2012, 2009 and 2006 IBC and Section Section R905.1 of the 2012, 2009 and 2006 IRC. Physical Properties: The roofing membranes covered under this Report have been tested for physical properties in accordance with ASTM D6878 and ASTM G155, and therefore qualify for use under Section 1507.13.2 and Section 1504.6 of the 2012, 2009 and 2006 IBC and Section R905.13.2 of the 2012, 2009 and 2006 IRC. Impact Test: The single-ply roofing membranes covered under this Report have been tested for impact resistance in accordance with "Resistance to Foot Traffic Test" in Section 5.5 of FM 4470 and therefore qualify for use under Section 1504.7 of the 2012, 2009 and 2006 IBC. 5.1 Membranes: 5.1.1 JM TPO: Thermoplastic, polyester reinforced membrane manufactured using an ultraviolet-resistance thermoplastic polyolefin formulation. JM TPO 45 is a nominal 45 mil membrane and available in a white weathering surface (grey or tan are special order). The membrane is supplied in 500 sq ft, 800 sq ft or 1000 sq ft rolls. JM TPO 60 is a nominal 60 mil membrane and available in a white, grey or tan weathering surface. The membrane supplied in 500 sq ft, 800 sq ft or 1000 sq ft rolls. JM TPO 72 is a nominal 72 mil membrane and available in a white, grey or tan weathering surface. The membrane is supplied in 750 sq ft rolls and is a special order item. JM TPO 80 is a nominal 80 mil membrane and available in a white weathering surface (grey or tan are special order). The membrane is supplied in 375 sq ft, 600 sq ft, or 750 sq ft rolls. Reflexsa is a nominal 60 mil membrane and available in a bright white weathering surface. The membrane is supplied in 1000 sq ft rolls and is a special order item. 5.1.2 JM TPO FB: Thermoplastic polyolefin membrane with a reinforced polyester fabric and integral polyester fleece backing. JM TPO FB115 is a nominal 60 mil membrane and available in white weathering surface (grey or tan are special order). The membrane is supplied in 1000 sq ft rolls. JM TPO FB 135 is a nominal 80 mil membrane and available in white weathering surface (grey or tan are special order). The membrane is supplied in 500 sq ft rolls. 5.2 Insulation: Foam plastic insulation when used shall have a flame spread index of not more than 75 when tested at the maximum thickness intended for the use in accordance with ANSI/UL 723 or ASTM E 84 to qualify for use under Section 2603.3 and Exception 3 of the 2012, 2009 and 2006 IBC. To qualify for use under Section 2603.4.1.5 of the 2012, 2009 and 2006 IBC, a thermal barrier is not required for foam plastic insulation that is part of a Class A, B or C roof-covering assembly, provided the assembly with foam plastic insulation complies with FM 4450 or UL 1256. RECEIVED Page3of34 04/23/2018 ASPEN BUILDING DEPARTMENT 5.3 Fasteners: Fasteners used to mechanically fasten insulation and membranes to the roof deck, shall be corrosion resistant and shall be one of the fasteners identified in Note 2 in the Appendix of this Report. 5.4 Adhesive: The adhesive used to adhere Johns Manville's TPO membranes to the insulation or roofing substrate shall be as noted in the Appendix of this Report. 5.4 Asphalt: Hot roofing asphalt, when specified in the roofing assemblies shall conform to ASTM D312, Type III or Type IV. 6. INSTALLATION Johns Manville single ply membranes shall be installed in accordance with the applicable code, this report and the manufacturer's published installation instructions. The membranes shall be installed in accordance with Section 1507.13 of the 2012, 2009 and 2006 IBC or Section R905.13 of the 2012, 2009 and 2006 IRC as applicable, except as noted in this report. The manufacturer's published installation instructions shall be available at all times on the jobsite during installation. The slope of the roof on which the membranes are installed shall be a minimum of 1/4:12 (2% slope)and shall not be more than the maximum slope indicated in the Tables in the Appendix of this Report. Penetrations and terminations of the roof covering shall be flashed and made watertight in accordance with the requirements of the membrane manufacturer, Section 1503.2 of 2012, 2009 and 2006 IBC or Section R903.2 of 2012, 2009 and 2006 IRC and applicable code. 7. Fire Classification 7.1 New Construction: Roof assemblies utilizing Johns Manville JM TPO 45, JM TPO 60, JM TPO 72, JM TPO 80, JM TPO Reflexsa, JM TPO FB 115 and JM TPO FB 135 thermoplastic single ply roof coverings are described in UL Certification Category for Roofing Systems, (TGFU), File R10167 (TGFU Link)and in Tables provided in the Appendix. 7.2 Reroofing: The existing roof shall be inspected in accordance with the provisions and limitations of Section 1510 of the 2012, 2009 and 2006 or Section R907 of the 2012, 2009 and 2006 IRC, as applicable. The existing deck shall be inspected to verify that the structure to be reroofed is structurally sound and adequate to support and secure the roofing membrane. Prior to installation of new roof coverings, inspection by and approval from the code official having jurisdiction is required. Johns Manville JM TPO membranes may be installed over existing Classified Class A, B or C roofing systems as described in the UL Certification Category for Roofing Systems (TGFU), File R10167 (TGFU Link) under the heading Class A, B and C (TPO)for Maintenance and Repair for applicable coverage and details of the roof assemblies and in the Tables in the Appendix of this Report. RECEIVED Page4of34 04/23/2018 ASPEN BUILDING DEPARTMENT Class A, B or C roof coverings may be installed over existing classified roof assemblies under the following conditions without additional roof classification tests, provided the resulting classification is the lower of the new and existing roof classifications under the following conditions: • New uninsulated roof coverings installed only over existing uninsulated assemblies. • New insulated roof coverings installed over existing uninsulated assemblies only. 8. Wind Resistance 8.1 New Construction: The allowable wind uplift pressures for the roof assemblies are noted in the Tables in Appendix of this Report. Metal edge securement for all systems shall be designed in accordance with ANSI/SPRI ES-1, complying with Section 1504.5 of 2012, 2009 and 2006 IBC. For certifications of metal edge securement systems in accordance with ANSI/SPRI ES-1, See UL Online Certifications Directory Roof-edge Systems, Metal for Use with Low-slope Roofing Systems (TGJZ). 8.2 Reroofing: Roof covering systems employing mechanical fasteners shall be qualified, to the satisfaction of the code official, as to the adequacy of fasteners penetrating through existing roof coverings into structural substrates. Since the composition and/or conditions of any particular underlying existing roofing materials may vary and reroofing material may vary, reroofing with adhered systems is outside the scope of this report. 9. CONDITIONS OF USE The Johns Manville single ply roofing membranes described in this Report comply with, or are suitable alternatives to, what is specified in those codes listed in Section 2 of this Report, subject to the following conditions: 9.1 Materials and methods of installation shall comply with this Report and the manufacturer's published installation instructions. In the event of a conflict between the installation instructions and this Report, this Report governs. 9.2 Johns Manville thermoplastic single ply roofing membranes shall be installed by professional roofing contractors trained and approved by the manufacturer. 9.3 See UL Online Certification Directory Roofing Systems (TGFU) File R10167. (TGFU Link) Also refer to the Tables in the Appendix of this Report. 9.4 Above-deck thermal insulation board shall comply with the applicable standards listed in Table 1508.2 in Section 1508.2 of 2012, 2009 and 2006 IBC. 9.5 Wind uplift pressures on any roof area, including edges and corner zones shall not exceed the allowable wind pressure for the roof covering installed in that particular area. Refer to the Tables in the Appendix of this Report. 9.6 The allowable wind uplift pressures listed in the Tables in the Appendix of this Report are for the roof systems only. The deck and framing to which the roofing system is attached shall be designed for the applicable components and cladding, wind loads in accordance with the applicable codes. 9.7 When application is over an existing roof, documentation of the wind uplift resistance of the composite roof construction shall be submitted to the code official. RECEIVED Page5of34 04/23/2018 ASPEN BUILDING DEPARTMENT 9.8 The metal edge securement shall be designed and installed for wind loads in accordance with Chapter 16 of 2012, 2009 and 2006 IBC and test for resistance in accordance with Test Methods RE-1, RE-2 and RE-3 of ANSI/SPRI ES-1, except V,It wind speed shall be determined from Figure 1609A, 1609B, or 1609C of 2012, 2009 and 2006 IBC as applicable. 9.9 The Johns Manville thermoplastic single ply membranes covered under this report are produced by Johns Manville in Scottsboro, AL under the UL LLC Classification and Follow-Up Service Program, which includes audits in accordance with quality elements of ICC-ES Acceptance Criteria for Quality Documentation, AC 10. 10. SUPPORTING EVIDENCE 10.1 Data in accordance with ICC-ES Acceptance Criteria for Membrane Roof-Covering Systems, AC75. 10.2 Manufacturer's descriptive product literature, including installation instructions. 10.3 UL Classification Reports in accordance with ANSI/UL 790. See UL Product Certification Category for Roofing Systems (TGFU), File R10167. 10.4 Data in accordance with FM 4474. 10.5 Data in accordance with FM 4470. 10.6 Data in accordance with ASTM D6878 and ASTM G155. 10.7 Documentation of quality system elements in accordance with ICC-ES Acceptance Criteria for Quality Documentation, AC10. 11. IDENTIFICATION The Johns Manville thermoplastic single ply membranes described in this evaluation report are identified by a marking bearing the report holder's name (Johns Manville), the plant identification (if required), the product designation, the UL Classification Mark, and the evaluation report number UL ER10167-01. The validity of the evaluation report is contingent upon this identification appearing on the product or UL Classification Mark certificate. 12. USE OF UL EVALUATION REPORT 12.1 The approval of building products, materials or systems is under the responsibility of the applicable authorities having jurisdiction. 12.2 UL Evaluation Reports shall not be used in any manner that implies an endorsement of the product, material or system by UL. 12.3 The current status of this report, as well as a complete directory of UL Evaluation Reports may be found at UL.com via our On-Line Certifications Directory: www.UL.com/database www.ul.com/erdirectory RECEIVED Page6of34 04/23/2018 ASPEN BUILDING DEPARTMENT APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE Table Deck Application Type Description lA Wood New, Reroof(Tear-Off), Recover C Mechanically Attached Insulation, Bonded Roof Cover 1B Wood New, Reroof(Tear-Off), Recover D Insulated, Mechanically Attached Roof Cover 2A Steel or Conc. New, Reroof(Tear-Off), Recover B Mechanically Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 2B-1 Steel or Conc. New, Reroof(Tear-Off), Recover C-1 Mechanically Attached Insulation, Bonded Roof Cover 2B-1 Steel or Conc. New, Reroof(Tear-Off), Recover C-2 Mechanically Attached Insulation, Plate-Bonded or Strip-Bonded Roof Cover 2C Steel or Conc. New, Reroof(Tear-Off), Recover D Insulated, Mechanically Attached Roof Cover 3A-1 Concrete New, Reroof(Tear-Off) A-la Bonded Insulation, Bonded Roof Cover 3A-2 Concrete New, Reroof(Tear-Off) A-lb Bonded Temp Roof, Bonded Insulation, Bonded Roof Cover 4A LWIC New, Reroof(Tear-Off) F Non-Insulated, Bonded Roof Cover 5A Gypsum Reroof(Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 6A Various Recover A-1 Bonded Insulation, Bonded Roof Cover 6B Various Recover Over Existing Metal Roof C-2 Mech. Attached Insulation, Plate-Bonded Roof Cover 6C Various Recover Over Existing Metal Roof D Insulated, Mechanically Attached Roof Cover 6D Various Recover F Non-Insulated, Bonded Roof Cover The following notes apply to the systems outlined herein: 1. Roof decks shall be in accordance with IBC or IRC requirements to the satisfaction of the AHJ. Wind load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. Wind load resistance of the roof deck shall be documented through proper codified Approval documentation. 2. Unless otherwise noted, fasteners and stress plates for insulation attachment shall be as follows. Fasteners shall be of sufficient length for the following engagements: ➢ Steel Deck: UltraFast #12 or #14 with UltraFast 3 in. Round Metal Plates or UltraFast Square Recessed Metal Plates. Minimum 3/4-inch steel penetration, engage the top flute of the steel deck. Concrete Deck: UltraFast #14 with UltraFast 3 in. Round Metal Plates or UltraFast Square Recessed Metal Plates or JM Structural Concrete Deck Fasteners and Plates. Minimum 1-inch embedment. Fasteners installed with a pilot hole in accordance with the fastener manufacturer's published installation instructions. 3. Minimum 200 psi, minimum 2-inch thick lightweight insulating concrete may be substituted for rigid insulation board for System Type D (mechanically attached membrane), whereby the membrane fasteners are installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater configuration to the steel and concrete deck listings. 4. Preliminary insulation attachment for System Type D = Minimum four fasteners per 4 x 8 ft board or minimum two fasteners per 4 x 4 ft board. RECEIVED Page 7 of 34 04/23/2018 ASPEN BUILDING DEPARTMENT 5. Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturer's published instructions: ➢ Hot asphalt [HA]: Full coverage at 20-25 lbs/sq. ➢ JM Urethane Insulation Adhesive [JM UTA]: Continuous 0.75-inch ribbons, 12-inch o.c. • JM Two-Part Urethane Insulation Adhesive [JM UTA-TWO-PART]: Continuous 0.75-inch ribbons, 12-inch o.c. Note: JM Green Two-Part Urethane Insulation Adhesive may be used where UIA-TWO-PART is referenced • 3M Roofing System Urethane Adhesive (JM-RSUA): Continuous 0.5 to 0.75-inch wide ribbons, 12-inch o.c. ➢ 3M One-Step Foamable Adhesive [JM-OSFA]: Continuous 0.75-inch ribbons, 12-inch o.c. • Note: When multiple layers(s) of insulation and/or coverboard are installed in ribbon-applied adhesive, adhesive ribbons shall be staggered from layer-to-layer a distance of one- half the ribbon spacing. Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing 6. Unless otherwise noted, all insulations are flat stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum Design Pressure (MDP) limitations. In no case shall these values be used to 'increase' the MDP listings in the tables; rather if MDP listing below meets or exceeds that listed for a particular system in the tables, then the thinner board listed below may be used as a drop-in for the equivalent thicker material listed in the table: ➢ JM Two-Part Urethane Insulation Adhesive [JM UTA-TWO-PART]: MDP: -315.0 psf (Min. 0.5-inch thick) • JM Roofing System Urethane Adhesive (JM RSUA): MDP -157.5 psf (Min. 0.5-inch thick) ➢ JM One-Step Foamable Adhesive [JM-OSFA]: MDP: -157.5 psf (Min. 0.5-inch thick) 7. Bonded polyisocyanurate insulation boards shall be maximum 4 x 4 ft. 8. For System Type D, steel deck applications, the roof membrane shall be run with its length perpendicular to the steel deck flutes. 9. For Recover Applications using System Type D, the insulation is optional. Alternatively, min. 0.25-inch Invinsa, DensDeck, DensDeck Prime ,SECUROCK Gypsum-Fiber RoofBoard may be used as a separator board, preliminarily attached prior to roof cover installation. The existing roof system shall be suitable for a recover application. 10. For adhered membrane systems, side laps shall be minimum 2-inch wide sealed with min. 1.5-inch heat weld. Adhesive application rates are as follows: Membrane Adhesive Method Rate JM TPO JM TPO Membrane Adhesive(Solvent Based)[JM TPO MA-SB] Contact(both sides) 1.67 gal/square(A applied to substrate and'A applied to membrane) JM TPO JM TPO Membrane Adhesive(Low VOC)[JM TPO MA-LVOC] Contact(both sides) 1.67 gal/square(y:applied to substrate and'A applied to membrane) JM TPO JM TPO Membrane Adhesive(Water Based)[JM TPO MA-WB] Wet lay(substrate) 1.10 gal/square JM TPO FB JM TPO Membrane Adhesive(Water Based)[JM TPO MA-WB] Wet lay(substrate) 0.83 to 1 gal/square JM TPO FB JM Roofing System Urethane Adhesive(JM-RSUA) Wet lay(substrate) 0.5 to 0.75-inch wide ribbons spaced as noted in tables herein. 11. "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609.1.5 for determination of design wind loads. RECEIVED Page8of34 04/23/2018 ASPEN BUILDING DEPARTMENT TABLE lA-1: WOOD DECKS-NEW CONSTRUCTION or REROOF(Tear-Off)or RECOVER SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION,BONDED ROOF COVER Top Insulation Layer Roof Cover Fire Rating System Deck MDP UL79O/E1O8 No. (See Note 1) Base Insulation Layer (psf) Max Type Fasteners Attach Type Attach Class Incline (in.) Min. 1.5-inch ENRGY 3, ENRGY 3 AGF, ENRGY 3 CGF, ENRGY 3 25 PSI, Min 3/4 in.plywood or ENRGY 3 25 PSI AGF, W-1 wood plank at max 24 ENRGY 3 25 PSI CGF,JM Min.7/16-in.OSB See Note 2 1 per 2 ft2 JM TPO FB115 or 135 JM TPO MA-WB -45.0 A 1/2 ISO 3,ValuTherm, in.spans ValuTherm AGF,ValuTherm CGF,ValuTherm 25 PSI AGF,ValuTherm 25 PSI CGF,loose laid TABLE 1B-1: WOOD DECKS-NEW CONSTRUCTION, REROOF(Tear-Off)or RECOVER SYSTEM TYPE D: INSULATED, MECHANICALLY ATTACHED ROOF COVER(STRESS PLATES) Insulation Roof Cover Fire Rating UL790/E108 System Deck MDP Max No. (See Note 1) Type Attachment Membrane Fasteners Attachment (psf) Class Incline (in.) Min. 1.5-inch ENRGY 3, ENRGY 3 AGF, ENRGY 3 CGF, ENRGY 3 Min. 19/32 in. plywood at 25 PSI, ENRGY 3 24 in. spans with blocking 25 PSI AGF, JM TPO 45, 6-in. oc within 6-in. wide at unsupported joints ENRGY 3 25 PSI 60,72 or 80, Prelim. High Load Fasteners with laps spaced 90-in. oc W-2 attached with 10d ring CGF,JM ISO 3, JM TPO -60.0 A 1/2 shank nails spaced 4-in. ValuTherm, attached Reflexsa (8 ft High Load Seam Plates Laps sealed with 1.5-in. oc at perimeter and ValuTherm AGF, sheet) heat weld outside lap intermediate supports ValuTherm CGF, ValuTherm 25 PSI AGF, ValuTherm 25 PSI CGF RECEIVED Page 9 of 34 04/23/2018 ASPEN BUILDING DEPARTMENT TABLE 2A: STEEL or CONCRETE DECKS-NEW CONSTRUCTION or REROOF(Tear-Off)or RECOVER SYSTEM TYPE B: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION,BONDED ROOF COVER Base Insulation Layer Top Insulation Layer Roof Cover Fire Rating System Deck MDP UL790/E108 No. (See Note 1) (psf) Max Type Fastener Attach Type Attach Type Attach Class Incline 1 (in.) JM TPO APPLICATIONS: Min. 22 ga.,type Min. 1.5-inch ENRGY 3,ENRGY 3 AGF, JM TPO ENRGY 3 CGF,ENRGY 3 25 PSI,ENRGY 3 25 JM TPO 45, MA-WB,JM A 1/2 B,Grade 33 Min. 0.5-in. JM UTA- PSI AGF,ENRGY 3 25 PSI CGF,JM ISO 3, See Note 1 per 2 60,72 or 80, TPO MA-SB SC-1 steel or min. RetroPlus TWO- -45.0 ValuTherm,ValuTherm AGF,ValuTherm 2 ft2 JM TPO 2,500 psi JM TPO CGF,ValuTherm 25 PSI AGF,ValuTherm 25 Board PART Reflexsa A 3/4 concrete p5I CGF MA-LVOC type Min. 1.5-inch ENRGY 3,ENRGY 3 AGF, JM TPO Min. 22 ga., ENRGY 3 CGF,ENRGY 3 25 PSI,ENRGY 3 25 JM TPO 45, MA-WB,JM A 1/2 B,Grade 33 Min. 0.5-inch PSI AGF,ENRGY 3 25 PSI CGF,JM ISO 3, See Note 1 per 2 60,72 or 80, TPO MA-SB SC-2 steel or min. ValuTherm,ValuTherm AGF,ValuTherm 2 ft2 RetroPlus JM-RSUA JM TPO -45.0 2,500 psi JM TPO CGF,ValuTherm 25 PSI AGF,ValuTherm 25 Board Reflexsa A 3/4 concrete pSI CGF MA-LVOC JM TPO FB APPLICATIONS: Min. 22 ga.,type Min. 1.5-in. ENRGY 3,ENRGY 3 AGF,ENRGY 3 CGF,ENRGY 3 25 PSI,ENRGY 3 25 PSI B,Grade 33 Additional AGF,ENRGY 3 25 PSI CGF,JM ISO 3, See Note 1 per 2 JM TPO FB JM TPO SC-3 steel or min. layer(s)base JM UTA -45.0 A 1/2 2,500 psi ValuTherm,ValuTherm AGF,ValuTherm 2 ft2 insulation 115 or 135 MA-WB concrete CGF,ValuTherm 25 PSI AGF,ValuTherm 25 PSI CGF SC-4 Min. 22 ga.,type Min. 1.5-inch ENRGY 3,ENRGY 3 AGF, B,Grade 33 ENRGY 3 CGF,ENRGY 3 25 PSI,ENRGY 3 25 Additional steel or min. PSI AGF,ENRGY 3 25 PSI CGF,JM ISO 3, See Note 1 per 2 Hot JM TPO FB JM TPO 2,500 psi ValuTherm,ValuTherm AGF,ValuTherm 2 ft2 layer(s)base Asphalt 115 or 135 MA-WB -45.0 A 1/2 concrete CGF,ValuTherm 25 PSI AGF,ValuTherm 25 insulation PSI CGF SC-5 Min. 22 ga.,type Min. 1.5-inch ENRGY 3,ENRGY 3 AGF, B,Grade 33 ENRGY 3 CGF,ENRGY 3 25 PSI,ENRGY 3 25 Additional JM UTA steel or min. PSI AGF,ENRGY 3 25 PSI CGF,JM ISO 3, See Note 1 per 2 JM TPO FB JM TPO 2,500 psi ValuTherm,ValuTherm AGF,ValuTherm 2 ft2 layer(s)base TWO 115 or 135 MA-WB -45.0 A 1/2 concrete CGF,ValuTherm 25 PSI AGF,ValuTherm 25 insulation PART PSI CGF Min. 22 ga.,type Min. 1.5-inch ENRGY 3,ENRGY 3 AGF, ENRGY 3 CGF,ENRGY 3 25 PSI,ENRGY 3 25 B,Grade 33 Min. 0.5-inch JM UTA- PSI AGF,ENRGY 3 25 PSI CGF,JM ISO 3, See Note 1 per 2 JM TPO 115 JM TPO SC-6 steel or min. RetroPlus TWO- -45.0 A 1/2 2,500 psi ValuTherm,ValuTherm AGF,ValuTherm 2 ft2 Board PART or 135 MA-WB concrete CGF,ValuTherm 25 PSI AGF,ValuTherm 25 PSI CGF RECEIVED Page 10of34 04/23/2018 ASPEN BUILDING DEPARTMENT TABLE 2A: STEEL or CONCRETE DECKS-NEW CONSTRUCTION or REROOF (Tear-Off) or RECOVER SYSTEM TYPE B: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION,BONDED ROOF COVER Base Insulation Layer Top Insulation Layer Roof Cover Fire Rating System Deck MDP — UL790/E108 No. (See Note 1) (psf) Max Type Fastener Attach Type Attach Type Attach Class Incline (in.) Min.2-in. ENRGY 3,ENRGY 3 AGF, ENRGY 3 Min. 22 ga.,type Min.0.25-in CGF,ENRGY 3 25 PSI,ENRGY 3 25 PSI AGF, JM UTA- JM TPO B,Grade 33 steel See Note 1 per 4 SECUROCK JM TPO SC-7 ENRGY 3 25 PSI CGF,JM ISO 3,ValuTherm, TWO- FB 115 -37.5 A 2 or min. 2,500 psi ValuTherm AGF,ValuTherm CGF,ValuTherm 2 ft2 Gypsum-Fiber Roof PART or 135 MA-WB concrete 25 PSI AGF,ValuTherm 25 PSI CGF Board Min.2-in. ENRGY 3,ENRGY 3 AGF,ENRGY 3 Min. 22 ga.,type Min.0.25-in CGF,ENRGY 3 25 PSI,ENRGY 3 25 PSI AGF, JM UTA- JM TPO B,Grade 33 steel See Note 1 per SECUROCK JM TPO SC-8 or min. 2,500 psi ENRGY 3 25 PSI CGF,JM ISO 3,ValuTherm, 2 2.67 ft2 Gypsum-Fiber Roof TWO- FB 115 MA-WB -45.0 A 2 concrete ValuTherm AGF,ValuTherm CGF,ValuTherm Board PART or 135 25 PSI AGF,ValuTherm 25 PSI CGF Min. 22 ga.,type Min. 1.5-inch ENRGY 3,ENRGY 3 AGF,ENRGY 3 CGF,ENRGY 3 25 PSI,ENRGY 3 25 PSI AGF, JM TPO B,Grade 33 steel See Note 1 per 2 Min.0.5-inch JM TPO SC-9 or min. 2,500 psi ENRGY 3 25 PSI CGF,JM ISO 3,ValuTherm, 2 ft2 RetroPlus Board JM-RSUA FB 115 MA-WB -45.0 A 1/2 concrete ValuTherm AGF,ValuTherm CGF,ValuTherm or 135 25 PSI AGF,ValuTherm 25 PSI CGF Min. 22 ga.,type Min. 1.5-inch ENRGY 3,ENRGY 3 AGF,ENRGY Min.0.5-inch 3 CGF,ENRGY 3 25 PSI,ENRGY 3 25 PSI AGF, Invinsa or JM TPO JM-RSUA, SC-10 B,Grade 33 steel ENRGY 3 25 PSI CGF,JM ISO 3,ValuTherm, See Note 1 per 1 SECUROCK JM-RSUA FB 115 12-inch -67.5 A 1/2 or min. 2,500 psi ValuTherm AGF,ValuTherm CGF,ValuTherm 2 ft2 Gypsum-Fiber Roof or 135 o.c. concrete 25 PSI AGF,ValuTherm 25 PSI CGF Board Min.2-inch ENRGY 3,ENRGY 3 AGF,ENRGY 3 Min. 22 ga.,type CGF,ENRGY 3 25 PSI,ENRGY 3 25 PSI AGF, Min.0.25-inch JM TPO B,Grade 33 steel See Note 1 per 4 SECUROCK JM TPO SC-11 or min. 2,500 psi ENRGY 3 25 PSI CGF,JM ISO 3,ValuTherm, 2 ft2 Gypsum-Fiber Roof JM-OSFA FB 115 MA-WB -37.5 A 2 concrete ValuTherm AGF,ValuTherm CGF,ValuTherm Board or 135 25 PSI AGF,ValuTherm 25 PSI CGF Min.2-inch ENRGY 3,ENRGY 3 AGF,ENRGY 3 Min. 22 ga.,type Min.0.25-inch CGF,ENRGY 3 25 PSI,ENRGY 3 25 PSI AGF, JM TPO B,Grade 33 steel See Note 1 per SECUROCK JM TPO SC-12 or min. 2,500 psi ENRGY 3 25 PSI CGF,JM ISO 3,ValuTherm, 2 2.67 ft2 Gypsum-Fiber Roof JM-OSFA FB 115 MA-WB -45.0 A 2 concrete ValuTherm AGF,ValuTherm CGF,ValuTherm Board or 135 25 PSI AGF,ValuTherm 25 PSI CGF RECEIVED Page 11of34 04/23/2018 ASPEN BUILDING DEPARTMENT TABLE 2B-1: STEEL or CONCRETE DECKS-NEW CONSTRUCTION,REROOF(Tear-Off)or RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION,BONDED ROOF COVER Top Insulation Layer Roof Cover I Fire Rating UL790/E108 System Roof Deck Base Insulation Layer MDP Max (psf) No. Type Fasteners Attach Type Attach Class Incline (in.) JM TPO APPLICATIONS: (Optional)One or more layers,ENRGY 3, JM TPO MA- Min. 22 ga.,type B, ENRGY 3 AGF,ENRGY 3 CGF,ENRGY 3 JM TPO 45, WB,JM TPO A 1/2 25 PSI,ENRGY 3 25 PSI AGF,ENRGY 3 MA-SB SC-13 Grade 33 steel or 25 PSI CGF,JM ISO 3,ValuTherm, Min. 1.75-inch See Note 2 1 per 4 ft2 60,72 or 80, -30.0 min.2,500 psi Invinsa Foam JM TPO concrete ValuTherm AGF,ValuTherm CGF, Reflexsa JM TPO MA- ValuTherm 25 PSI AGF,ValuTherm 25 LVOC A 3 PSI CGF,any combination,loose laid One or more layers,ENRGY 3,ENRGY 3 AGF,ENRGY 3 CGF,ENRGY 3 25 PSI, Min. 22 ga.,type B, JM TPO 45, ENRGY 3 25 PSI AGF,ENRGY 3 25 PSI JM TPO MA- .Grade 33 steel or CGF,JM ISO 3,ValuTherm,ValuTherm Min.0.25 inch See Note 2 1 per 2 ft2 60,72 or 80, WB,JM TPO -30.0 A 1/2 min.2,500 psi AGF,ValuTherm CGF,ValuTherm 25 PSI Invinsa JM TPO MA-SB concrete AGF,ValuTherm 25 PSI CGF,any Reflexsa combination,loose laid One or more layers,ENRGY 3,ENRGY 3 Min. 22 ga., AGF,ENRGY 3 CGF,ENRGY 3 25 PSI, type B, JM TPO 45, ENRGY 3 25 PSI AGF,ENRGY 3 25 PSI JM TPO MA- .Grade 33 steel or CGF,JM ISO 3,ValuTherm,ValuTherm Min.0.25-inch See Note 2 1 per 2 ft2 60,72 or 80, WB,JM TPO -30.0 A 3/4 min.2,500 psi AGF,ValuTherm CGF,ValuTherm 25 PSI Dens Deck JM TPO MA-SB concrete AGF,ValuTherm 25 PSI CGF,any Reflexsa combination,loose laid One or more layers,ENRGY 3,ENRGY 3 AGF,ENRGY 3 CGF,ENRGY 3 25 PSI, Min. 22 ga.,type B, Min.0.25-inch JM TPO 45, ENRGY 3 25 PSI AGF,ENRGY 3 25 PSI Grade 33 steel or SECUROCK 1 per 2.67 60,72 or 80, JM TPO MA- SC-16 CGF,JM ISO 3,ValuTherm,ValuTherm See Note 2 -37.5 A 1/2 min.2,500 psi AGF,ValuTherm CGF,ValuTherm 25 PSI Gypsum-Fiber ft2 JM TPO WB concrete AGF,ValuTherm 25 PSI CGF,any Roof Board Reflexsa combination,loose laid One or more layers,ENRGY 3,ENRGY 3 AGF,ENRGY 3 CGF,ENRGY 3 25 PSI, Min. 22 ga.,type B, Min.0.25-inch JM TPO 45, ENRGY 3 25 PSI AGF,ENRGY 3 25 PSI Grade 33 steel or SECUROCK 1 per 2.67 60,72 or 80, JM TPO MA- SC-17 CGF,JM ISO 3,ValuTherm,ValuTherm See Note 2 -37.5 A 3/4 min.2,500 psi AGF,ValuTherm CGF,ValuTherm 25 PSI Gypsum-Fiber ft2 JM TPO LVOC concrete AGF,ValuTherm 25 PSI CGF,any Roof Board Reflexsa combination,loose laid RECEIVED Page12of34 04/23/2018 ASPEN BUILDING DEPARTMENT TABLE 2B-1: STEEL or CONCRETE DECKS-NEW CONSTRUCTION,REROOF(Tear-Off)or RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION,BONDED ROOF COVER Top Insulation Layer Roof Cover Fire Rating UL790/E108 System MDP Roof Deck Base Insulation Layer Max No. Type Fasteners Attach Type Attach (psf) Class Incline (in.) Min.2-inch ENRGY 3,ENRGY 3 AGF,ENRGY 3 (Optional)One or more layers,ENRGY 3, CGF,ENRGY 3 25 Min. 22 ga.,type B, ENRGY 3 AGF,ENRGY 3 CGF,ENRGY 3 PSI,ENRGY 3 25 JM TPO 45, 25 PSI,ENRGY 3 25 PSI AGF,ENRGY 3 PSI AGF,ENRGY 3 Grade 33 steel or 60,72 or 80, JM TPO MA- SC-18 min.2,500 psi 25 PSI CGF,JM ISO 3,ValuTherm, 25 PSI CGF,JM See Note 2 1 per 4 ft2 JM TPO WB -37.5 A 1/2 concrete ValuTherm AGF,ValuTherm CGF, ISO 3,ValuTherm, Reflexsa ValuTherm 25 PSI AGF,ValuTherm 25 ValuTherm AGF, PSI CGF,any combination,loose laid ValuTherm CGF, ValuTherm 25 PSI AGF,ValuTherm 25 PSI CGF Min.2-inch ENRGY 3,ENRGY 3 AGF,ENRGY 3 JM TPO MA- (Optional)One or more layers,ENRGY 3, CGF,ENRGY 3 25 SB A 1/2 Min. 22 ga.,type B, ENRGY 3 AGF,ENRGY 3 CGF,ENRGY 3 PSI,ENRGY 3 25 JM TPO 45, 25 PSI,ENRGY 3 25 PSI AGF,ENRGY 3 PSI AGF,ENRGY 3 SC-19 Grade 33 steel or 25 PSI CGF,JM ISO 3,ValuTherm, 25 PSI CGF,JM See Note 2 1 per 4 ft2 60,72 or 80, -45.0 min.2,500 psi ValuTherm AGF,ValuTherm CGF, ISO 3,ValuTherm, JM TPO concrete ValuTherm 25 PSI AGF,ValuTherm 25 ValuTherm AGF, Reflexsa PSI CGF,any combination,loose laid ValuTherm CGF, JM TPO MA- A 3/4 ValuTherm 25 PSI LVOC AGF,ValuTherm 25 PSI CGF Min. 1.5-inch ENRGY 3,ENRGY 3 AGF,ENRGY 3 JM TPO MA- (Optional)One or more layers,ENRGY 3, CGF,ENRGY 3 25 WB,JM TPO A 1/2 ENRGY 3 AGF,ENRGY 3 CGF,ENRGY 3 PSI,ENRGY 3 25 MA-SB Min. 22 ga.,type B, JM TPO 45, 25 PSI,ENRGY 3 25 PSI AGF,ENRGY 3 PSI AGF,ENRGY 3 SC-20 Grade 33 steel or 25 PSI CGF,JM ISO 3,ValuTherm, 25 PSI CGF,JM See Note 2 1 per 2 ft2 60,72 or 80, -45.0 min.2,500 psi ValuTherm AGF,ValuTherm CGF, ISO 3,ValuTherm, JM TPO concrete ValuTherm 25 PSI AGF,ValuTherm 25 ValuTherm AGF, Reflexsa PSI CGF,any combination,loose laid ValuTherm CGF, JM TPO-MA- A 3/4 ValuTherm 25 PSI LVOC AGF,ValuTherm 25 PSI CGF One or more layers,ENRGY 3,ENRGY 3 JM TPO MA- AGF,ENRGY 3 CGF,ENRGY 3 25 PSI, WB,JM TPO A 1/2 Min. 22 ga.,type B, JM TPO 45, ENRGY 3 25 PSI AGF,ENRGY 3 25 PSI MA-SB SC-21 Grade 33 steel or CGF,JM ISO 3,ValuTherm,ValuTherm Min. 1.75-inch See Note 2 1 per 2.9 60,72 or 80, -45.0 min.2,500 psi Invinsa Foam ft2 JM TPO MA- concrete AGF,ValuTherm CGF,ValuTherm 25 PSI Reflexsa JM TPO MA- A 3/4 AGF,ValuTherm 25 PSI CGF,any LVOC combination,loose laid RECEIVED Page 13of34 04/23/2018 ASPEN BUILDING DEPARTMENT TABLE 2B-1: STEEL or CONCRETE DECKS-NEW CONSTRUCTION,REROOF(Tear-Off)or RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION,BONDED ROOF COVER Top Insulation Layer Roof Cover Fire Rating System Base Insulation MDP UL790/E108 Roof Deck Max No. Layer Type Fasteners Attach Type Attach (psf) Class Incline (in.) One or more layers, ENRGY 3,ENRGY 3 JM TPO MA- AGF,ENRGY 3 CGF, WB,JM TPO A 1/2 ENRGY 3 25 PSI, MA-SB Min. 22 ga.,type B, ENRGY 3 25 PSI AGF, ENRGY 3 25 PSI CGF, JM TPO 45,60,72 SC-22 Grade 33 steel or JM ISO 3,ValuTherm, Min.0.625-inch SECUROCK See Note 2 1 per 4 ft2 or 80,JM TPO -45.0 min.2,500 psi ValuTherm AGF, Gypsum-Fiber Roof Board Reflexsa concrete ValuTherm CGF, ValuTherm 25 PSI AGF, JM TPO MA- A 3/4 LVOC ValuTherm 25 PSI CGF, any combination,loose laid One or more layers, ENRGY 3,ENRGY 3 AGF,ENRGY 3 CGF, ENRGY 3 25 PSI, Min. 22 ga.,type B, ENRGY 3 25 PSI AGF, ENRGY 3 25 PSI CGF, JM TPO 45,60,72 JM TPO MA- SC-23 Grade 33 steel or JM ISO 3,ValuTherm, Min.7/16-inch APA rated See Note 2 1 per 2 ft2 or 80,JM TPO WB,JM TPO -45.0 A 1/2 min.2,500 psi ValuTherm AGF, OSB Reflexsa MA-SB concrete ValuTherm CGF, ValuTherm 25 PSI AGF, ValuTherm 25 PSI CGF, any combination,loose laid (Optional)One or more layers,ENRGY 3, Min. 1.5-inch ENRGY 3, ENRGY 3 AGF,ENRGY 3 ENRGY 3 AGF,ENRGY 3 JM TPO MA- A 1/2 CGF,ENRGY 3 25 PSI, CGF,ENRGY 3 25 PSI, SB ENRGY 3 25 PSI AGF, Min. 22 ga.,type B, ENRGY 3 25 PSI AGF, Grade 33 steel or ENRGY 3 25 PSI CGF, ENRGY 3 25 PSI CGF,JM JM TPO 45,60,72 SC-24 min.2,500 psi JM ISO 3,ValuTherm, ISO 3,ValuTherm, See Note 2 1 per 1.78 ft2 or 80,JM TPO -52.5 concrete ValuTherm AGF, ValuTherm AGF,ValuTherm Reflexsa ValuTherm CGF, AGF,ValuTherm CGF, JM TPO MA- A 3/4 ValuTherm 25 PSI AGF, ValuTherm 25 PSI AGF, LVOC A 3/4 ValuTherm 25 PSI CGF, ValuTherm 25 PSA CGF any combination,loose laidI RECEIVED Page 14of34 04/23/2018 ASPEN BUILDING DEPARTMENT TABLE 2B-1: STEEL or CONCRETE DECKS-NEW CONSTRUCTION,REROOF(Tear-Off)or RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION,BONDED ROOF COVER Top Insulation Layer Roof Cover Fire Rating System Base Insulation MDP UL790/E108 Roof Deck Max (psf) No. Layer Type Fasteners Attach Type Attach Class Incline (in.) One or more layers, ENRGY 3,ENRGY 3 AGF,ENRGY 3 CGF, JM TPO MA- A 1/2 ENRGY 3 25 PSI, SB, Min. 22 ga.,type B, ENRGY 3 25 PSI AGF, ENRGY 3 25 PSI CGF, JM TPO 45,60,72 SC-25 Grade 33 steel or JM ISO 3,ValuTherm, Min.7/16-inch APA rated See Note 2 1 per 1.78 ft2 or 80,JM TPO -75.0 min.2,500 psi OSB concrete ValuTherm AGF, Reflexsa ValuTherm CGF, ValuTherm 25 PSI AGF, JM TPO MA- A 3/4 ValuTherm 25 PSI CGF, LVOC any combination,loose laid JM TPO FB APPLICATIONS: One or more layers, ENRGY 3,ENRGY 3 Min.2-inch ENRGY 3, AGF,ENRGY 3 CGF, ENRGY 3 AGF,ENRGY 3 ENRGY 3 25 PSI, CGF,ENRGY 3 25 PSI, Min. 22 ga.,type B, ENRGY 3 25 PSI AGF, ENRGY 3 25 PSI AGF, ENRGY 3 25 PSI CGF, Grade 33 steel or ENRGY 3 25 PSI CGF,JM JM TPO FB 115 or JM TPO MA- SC-26 min.2,500 psi JM ISO 3,ValuTherm, ISO 3,ValuTherm, See Note 2 1 per 4 ft2 135 Wg -37.5 A 1/2 concrete ValuTherm AGF, ValuTherm AGF,ValuTherm ValuTherm CGF, CGF,ValuTherm 25 PSI ValuTherm 25 PSI AGF, AGF,ValuTherm 25 PSI ValuTherm 25 PSI CGF, CGF any combination,loose laid One or more layers, ENRGY 3,ENRGY 3 AGF,ENRGY 3 CGF, ENRGY 3 25 PSI, Min. 22 ga.,type B, ENRGY 3 25 PSI AGF, ENRGY 3 25 PSI CGF, Grade 33 steel or Min.0.25-inch SECUROCK JM TPO FB 115 or JM TPO MA- SC-27 min.2,500 psi JM ISO 3,ValuTherm, Gypsum-Fiber Roof Board See Note 2 1 per 2.67 ft2 135 Wg -37.5 A 1/2 concrete ValuTherm AGF, ValuTherm CGF, ValuTherm 25 PSI AGF, ValuTherm 25 PSI CGF, any combination,loose laid RECEIVED Page 15of34 04/23/2018 ASPEN BUILDING DEPARTMENT TABLE 2B-1: STEEL or CONCRETE DECKS-NEW CONSTRUCTION,REROOF(Tear-Off)or RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION,BONDED ROOF COVER Top Insulation Layer Roof Cover Fire Rating System Base Insulation MDP UL790/E108 Roof Deck Max (psf) No. Layer Type Fasteners Attach Type Attach Class Incline (in.) One or more layers, ENRGY 3,ENRGY 3 Min.2-inch ENRGY 3, AGF,ENRGY 3 CGF, ENRGY 3 AGF,ENRGY 3 ENRGY 3 25 PSI, CGF,ENRGY 3 25 PSI, Min. 22 ga.,type B, ENRGY 3 25 PSI AGF, ENRGY 3 25 PSI AGF, ENRGY 3 25 PSI CGF, Grade 33 steel or ENRGY 3 25 PSI CGF,JM JM TPO FB 115 or JM TPO MA- -min.2,500 psi JM ISO 3,ValuTherm, ISO 3,ValuTherm, See Note 2 1 per 2 ft2 135 Wg 45.0 A 1/2 concrete ValuTherm AGF, ValuTherm AGF,ValuTherm ValuTherm CGF, CGF,ValuTherm 25 PSI ValuTherm 25 PSI AGF, AGF,ValuTherm 25 PSI ValuTherm 25 PSI CGF, CGF any combination,loose laid One or more layers, ENRGY 3,ENRGY 3 AGF,ENRGY 3 CGF, ENRGY 3 25 PSI, Min. 22 ga.,type B, ENRGY 3 25 PSI AGF, ENRGY 3 25 PSI CGF, Grade 33 steel or JM TPO FB 15 or JM TPO MA- SC-29 min.2,500 psi JM ISO 3,ValuTherm, Min.7/16-inch OSB See Note 2 1 per 2 ft2 135 WB -45.0 A 1/2 concrete ValuTherm AGF, ValuTherm CGF, ValuTherm 25 PSI AGF, ValuTherm 25 PSI CGF, any combination,loose laid One or more layers, ENRGY 3,ENRGY 3 AGF,ENRGY 3 CGF, ENRGY 3 25 PSI, Min. 22 ga.,type B, ENRGY 3 25 PSI AGF, ENRGY 3 25 PSI CGF, Grade 33 steel or Min. 5/8"SECUROCK JM TPO FB 15 or JM TPO MA- SC-30 min.2,500 psi JM ISO 3,ValuTherm, Gypsum-Fiber Roof Board See Note 2 1 per 4 ft2 135 WB -45.0 A 1/2 concrete ValuTherm AGF, ValuTherm CGF, ValuTherm 25 PSI AGF, ValuTherm 25 PSI CGF, any combination,loose laid RECEIVED Page 16of34 04/23/2018 ASPEN BUILDING DEPARTMENT TABLE 2B-2: STEEL OR CONCRETE DECKS- NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-2:MECHANICALLY ATTACHED INSULATION,PLATE-BONDED OR STRIP-BONDED ROOF COVER Attachment Fire Rating System Deck(See MDP UL790/E308 No. Note 1 Insulation Layer Roof Cover/Adhesive sf Max Fasteners Spacing (P ) Class Incline (in.) Min. 1.5-inch thick,one or more Min. 22 ga., layers,ENRGY 3,ENRGY 3 AGF, JM TPO 45,60,72 or 80,JM TPO Reflexsa type B,Grade ENRGY 3 CGF,ENRGY 3 25 PSI, bonded to JM TPO RhinoPlates with 33 steel at ENRGY 3 25 PSI AGF,ENRGY 3 25 PSI JM TPO RhinoPlates 18-inch o.c.at Rhinobond Plate bonding tool at 6 seconds SC-31 max. 6 ft span CGF,JM ISO 3,ValuTherm,ValuTherm and High Load rows spaced 60 per plate so tool reaches 400°F and cooled 37.5 A 3/4 or min. 2,500 AGF,ValuTherm CGF,ValuTherm 25 Fasteners inch o.c. with RhinoBond Cooling Clamps. Laps psi concrete PSI AGF,ValuTherm 25 PSI CGF,any sealed with 1.5-inch heat weld combination Min. 1.5-inch thick,one or more Min. 22 ga., layers,ENRGY 3,ENRGY 3 AGF, JM TPO 45,60,72 or 80,JM TPO Reflexsa type B,Grade ENRGY 3 CGF,ENRGY 3 25 PSI, bonded to JM TPO RhinoPlates with 33 steel at ENRGY 3 25 PSI AGF,ENRGY 3 25 PSI JM TPO RhinoPlates 6-inch o.c.at Rhinobond Plate bonding tool at 6 seconds SC-32 max. 6 ft span CGF,JM ISO 3,ValuTherm,ValuTherm and High Load rows spaced 120 per plate so tool reaches 400°F and cooled 45.0 A 3/4 or min. 2,500 AGF,ValuTherm CGF,ValuTherm 25 Fasteners inch o.c. with RhinoBond Cooling Clamps. Laps psi concrete PSI AGF,ValuTherm 25 PSI CGF,any sealed with 1.5-inch heat weld. combination Min. 1.5-inch thick,one or more Min. 22 ga., layers,ENRGY 3, ENRGY 3 AGF, JM TPO 45,60,72 or 80,JM TPO Reflexsa type B,Grade ENRGY 3 CGF,ENRGY 3 25 PSI, bonded to JM TPO RhinoPlates with JM TPO RhinoPlates 12-inch o.c.at SC 33 33 steel at ENRGY 3 25 PSI AGF,ENRGY 3 25 PSI and High Load rows spaced 60- Rhinobond Plate bonding tool at 6 seconds -52.5 A 3/4 max. 6 ft span CGF,JM ISO 3,ValuTherm,ValuTherm Fasteners inch o,c. per plate so tool reaches 400°F and cooled or min. 2,500 AGF,ValuTherm CGF,ValuTherm 25 with RhinoBond Cooling Clamps. Laps psi concrete PSI AGF,ValuTherm 25 PSI CGF,any sealed with 1.5-inch heat weld. combination Min. 1.5-inch thick,one or more Min. 22 ga., layers,ENRGY 3,ENRGY 3 AGF, JM TPO 45,60,72 or 80,JM TPO Reflexsa type B,Grade ENRGY 3 CGF,ENRGY 3 25 PSI, bonded to JM TPO RhinoPlates with 33 steel at ENRGY 3 25 PSI AGF,ENRGY 3 25 PSI JM TPO RhinoPlates 6-inch o.c.at Rhinobond Plate bonding tool at 6 seconds SC-34 max. 6 ft span CGF,JM ISO 3,ValuTherm,ValuTherm and High Load rows spaced 60 per plate so tool reaches 400°F and cooled 105.0 A 3/4 or min. 2,500 AGF,ValuTherm CGF,ValuTherm 25 Fasteners inch o.c. with RhinoBond Cooling Clamps. Laps psi concrete PSI AGF,ValuTherm 25 PSI CGF,any sealed with 1.5-inch heat weld. combination Min. 1.5-inch thick,one or more Min. 22 ga., layers,ENRGY 3,ENRGY 3 AGF, JM TPO 45,60,72 or 80,JM TPO Reflexsa type B,Grade ENRGY 3 CGF,ENRGY 3 25 PSI, bonded to JM TPO RhinoPlates with 33 steel at ENRGY 3 25 PSI AGF,ENRGY 3 25 PSI JM TPO RhinoPlates 1 per 5.33 ft2 Rhinobond Plate bonding tool at 6 seconds SC-35 45.0 A 3/4 max. 6 ft span CGF,JM ISO 3,ValuTherm,ValuTherm and High Load (6 parts per 4 x 8 per plate so tool reaches 400°F and cooled or min. 2,500 AGF,ValuTherm CGF,ValuTherm 25 Fasteners ft board) with RhinoBond Cooling Clamps. Laps psi concrete PSI AGF,ValuTherm 25 PSI CGF,any sealed with 1.5-inch heat weld. combination RECEIVED Page17of34 04/23/2018 ASPEN BUILDING DEPARTMENT TABLE 2B-2: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-2:MECHANICALLY ATTACHED INSULATION,PLATE-BONDED OR STRIP-BONDED ROOF COVER Attachment Fire Rating System Deck(See MDP UL790/E108 No. Note 1 Insulation Layer Roof Cover/Adhesive sf Max Fasteners Spacing (P ) Class Incline (in.) Min. 1.5-inch thick,one or more Min. 22 ga., layers,ENRGY 3,ENRGY 3 AGF, JM TPO 45,60,72 or 80,JM TPO Reflexsa type B,Grade ENRGY 3 CGF,ENRGY 3 25 PSI, z bonded to JM TPO RhinoPlates with 33 steel at ENRGY 3 25 PSI AGF,ENRGY 3 25 PSI JM TPO RhinoPlates 1 per 4 ft Rhinobond Plate bonding tool at 6 seconds SC-36 max. 6 ft span CGF,JM ISO 3,ValuTherm,ValuTherm and High Load (8 parts per 4 x 8 per plate so tool reaches 400°F and cooled -67.5 A 3/4 or min. 2,500 AGF,ValuTherm CGF,ValuTherm 25 Fasteners ft board) with RhinoBond Cooling Clamps. Laps psi concrete PSI AGF,ValuTherm 25 PSI CGF,any sealed with 1.5-inch heat weld. combination Min. 1.5-inch thick,one or more Min. 22 ga., layers,ENRGY 3,ENRGY 3 AGF, JM TPO 10"RPS JM TPO 45,60,72 or 80,JM TPO Reflexsa type B,Grade ENRGY 3 CGF,ENRGY 3 25 PSI, Fasteners 6-inch fastened with JM underside is primed with Primer 240 or SC-37 33 steel at ENRGY 3 25 PSI AGF,ENRGY 3 25 PSI High Load Seam o.c.through RPS ADCO SPC-3 Primer and walked-in over -52.5 A 3/4 max. 6 ft span CGF,JM ISO 3,ValuTherm,ValuTherm Plates and High at rows spaced the self-adhering RPS. Laps sealed with or min. 2,500 AGF,ValuTherm CGF,ValuTherm 25 Load Fasteners 114-inch o.c. 1.5-inch heat weld. psi concrete PSI AGF,ValuTherm 25 PSI CGF,any combination RECEIVED Page 18of34 04/23/2018 ASPEN BUILDING DEPARTMENT TABLE 2C: STEEL OR CONCRETE DECKS- NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D:INSULATED,MECHANICALLY ATTACHED ROOF COVER Insulation Roof Cover Fire Rating System Deck MDP UL790/E108 No. (See Note 1) (psf) Max Type Attach Membrane Fasteners Attachment Class Incline I (in.) SYSTEMS OVER MIN.GRADE 33 STEEL DECK OR STRUCTURAL CONCRETE(AS NOTED) Min. 1.5-inch thick,one or more Min.22 ga., layers,ENRGY 3,ENRGY 3 AGF, High Load Fasteners 12-inch o.c.within 6 type B,Grade ENRGY 3 CGF,ENRGY 3 25 PSI, JM TPO 45,60,72 (steel or concrete)or inch wide laps spaced 33 steel or ENRGY 3 25 PSI AGF,ENRGY 3 25 Prelim. or 80,JM TPO JM Structural Concrete SC-38 -30.0 A 3/4 min. 2,500 psi PSI CGF,JM ISO 3,ValuTherm, attached Reflexsa(8 ft Deck Fasteners 90-inch o.c. Laps structural ValuTherm AGF,ValuTherm CGF, sheet) (concrete only)with sealed with 1.5-inch concrete ValuTherm 25 PSI AGF,ValuTherm High Load SeamPlates heat weld outside lap 25 PSI CGF,any combination Min. 1.5-inch thick,one or more Min.22 ga., layers,ENRGY 3,ENRGY 3 AGF, High Load Fasteners 12-inch o.c.within 6- type B,Grade ENRGY 3 CGF,ENRGY 3 25 PSI, JM TPO 45,60,72 (steel or concrete)or inch wide laps spaced 33 steel or ENRGY 3 25 PSI AGF,ENRGY 3 25 Prelim. or 80,JM TPO JM Structural Concrete SC-39 min. 2,500 psi PSI CGF,JM ISO 3,ValuTherm, attached Reflexsa(10 ft Deck Fasteners 114-inch o.c. Laps -30.0 A 3/4 structural ValuTherm AGF,ValuTherm CGF, sheet) (concrete only)with sealed with 1.5-inch concrete ValuTherm 25 PSI AGF,ValuTherm High Load Seam Plates heat weld outside lap 25 PSI CGF,any combination Min. 1.5-inch thick,one or more Extra High Load Min.22 ga., layers,ENRGY 3,ENRGY 3 AGF, Fasteners(steel only) 12-inch o.c.within 6- type B,Grade ENRGY 3 CGF,ENRGY 3 25 PSI, JM TPO 45,60,72 or JM Structural inch wide laps spaced 33 steel or ENRGY 3 25 PSI AGF,ENRGY 3 25 Prelim. or 80,JM TPO SC-40 min. 2,500 psi PSI CGF,JM ISO 3,ValuTherm, attached Reflexsa(10 ft Concrete Deck 114-inch o.c. Laps -37.5 A 3/4 structural ValuTherm AGF,ValuTherm CGF, sheet) Fasteners(concrete sealed with 1.5-inch concrete ValuTherm 25 PSI AGF,ValuTherm only)with Extra High heat weld outside lap 25 PSI CGF,any combination Load Seam Plates Min. 1.5-inch thick,one or more Extra High Load Min.22 ga., layers,ENRGY 3,ENRGY 3 AGF, Fasteners(steel only) 12-inch o.c.within 6- type B,Grade ENRGY 3 CGF,ENRGY 3 25 PSI, JM TPO 45,60,72 or JM Structural inch wide laps spaced 33 steel or ENRGY 3 25 PSI AGF,ENRGY 3 25 Prelim. or 80,JM TPO SC-41 min. 2,500 psi PSI CGF,JM ISO 3,ValuTherm, attached Reflexsa(8 ft Concrete Deck 90-inch o.c. Laps -45.0 A 3/4 structural ValuTherm AGF,ValuTherm CGF, sheet) Fasteners(concrete sealed with 1.5-inch concrete ValuTherm 25 PSI AGF,ValuTherm only)with Extra High heat weld outside lap 25 PSI CGF,any combination Load Seam Plates Min. 1.5-inch thick,one or more Min.22 ga., layers,ENRGY 3,ENRGY 3 AGF, High Load Fasteners 6-inch o.c.within 6- type B,Grade ENRGY 3 CGF,ENRGY 3 25 PSI, JM TPO 45,60,72 (steel or concrete)or inch wide laps spaced 33 steel or ENRGY 3 25 PSI AGF,ENRGY 3 25 Prelim. or 80,JM TPO JM Structural Concrete SC-42 min. 2,500 psi PSI CGF,JM ISO 3,ValuTherm, attached Reflexsa(10 ft Deck Fasteners 114-inch o.c. Laps -45.0 A 3/4 structural ValuTherm AGF,ValuTherm CGF, sheet) (concrete only)with sealed with 1.5-inch concrete ValuTherm 25 PSI AGF,ValuTherm High Load Seam Plates heat weld outside lap 25 PSI CGF,any combination RECEIVED Page 19of34 04/23/2018 ASPEN BUILDING DEPARTMENT TABLE 2C: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D:INSULATED,MECHANICALLY ATTACHED ROOF COVER Fire Rating Insulation Roof Cover UL790/E108 System Deck MDP No. (See Note 1) (psf Max Type Attach Membrane Fasteners Attachment ) Class Incline (in.) Min. 1.5-inch thick,one or more Min.22 ga., layers,ENRGY 3,ENRGY 3 AGF, High Load Fasteners 6-inch o.c.within 6- type B,Grade ENRGY 3 CGF,ENRGY 3 25 PSI, JM TPO 45,60,72 (steel or concrete)or inch wide laps spaced 33 steel or ENRGY 3 25 PSI AGF,ENRGY 3 25 Prelim. or 80,JM TPO JM Structural Concrete SC-43 min. 2,500 psi PSI CGF,JM ISO 3,ValuTherm, attached Reflexsa(8 ft Deck Fasteners sea90- o.c. Laps -60.0 A 3/4 structural ValuTherm AGF,ValuTherm CGF, sheet) (concrete only)with sealed with 1.5-inch concrete ValuTherm 25 PSI AGF,ValuTherm High Load Seam Plates heat weld outside lap 25 PSI CGF,any combination Min. 2-inch thick,one or more Min.22 ga., layers,ENRGY 3,ENRGY 3 AGF, High Load Fasteners 6-inch o.c.within 6- type B,Grade ENRGY 3 CGF,ENRGY 3 25 PSI, JM TPO 45,60,72 (steel or concrete)or inch wide laps spaced 33 steel or ENRGY 3 25 PSI AGF,ENRGY 3 25 Prelim. or 80,JM TPO JM Structural Concrete SC 44 -82.5 A 3/4 min. 2,500 psi PSI CGF,JM ISO 3,ValuTherm, attached Reflexsa(5 ft Deck Fasteners 54-inch o.c. Laps structural ValuTherm AGF,ValuTherm CGF, sheet) (concrete only)with sealed with tsi inch concrete ValuTherm 25 PSI AGF,ValuTherm High Load Seam Plates heat weld outside lap 25 PSI CGF,any combination Min. 1.5-inch thick,one or more Min.22 ga., layers,ENRGY 3,ENRGY 3 AGF, High Load Fasteners 12-inch o.c.within 6- type B,Grade ENRGY 3 CGF,ENRGY 3 25 PSI, (steel or concrete)or JM TPO 45,60,72 inch wide laps spaced 33 steel or ENRGY 3 25 PSI AGF,ENRGY 3 25 Prelim. JM Structural Concrete SC 45 min. 2,500 psi PSI CGF,JM ISO 3,ValuTherm, attached or 80,JM TPO Deck Fasteners 114-inch o.c. Laps -30.0 A 3/4 structural ValuTherm AGF,ValuTherm CGF, Reflexsa (concrete only)with sealed with 1.5-inch concrete ValuTherm 25 PSI AGF,ValuTherm High Load Seam Plates heat weld outside lap 25 PSI CGF,any combination SYSTEMS OVER MIN.GRADE 80 STEEL DECK OR STRUCTURAL CONCRETE(AS NOTED) I Min. 1.5-inch thick,one or more Min.22 ga., layers,ENRGY 3,ENRGY 3 AGF, High Load Fasteners 12-inch o.c.within 6- type B,Grade ENRGY 3 CGF,ENRGY 3 25 PSI, JM TPO 45,60,72 (steel or concrete)or inch wide laps spaced 80 steel or ENRGY 3 25 PSI AGF,ENRGY 3 25 Prelim. or 80,JM TPO JM Structural Concrete SC 46 min. 2,500 psi PSI CGF,JM ISO 3,ValuTherm, attached Reflexsa(8 ft Deck Fasteners se90 inch o.c. Laps -37.5 A 3/4 structural ValuTherm AGF,ValuTherm CGF, sheet) (concrete only)with sealed with 1.5-inch concrete ValuTherm 25 PSI AGF,ValuTherm High Load Seam Plates heat weld outside lap 25 PSI CGF,any combination Min. 1.5-inch thick,one or more Min.22 ga., layers,ENRGY 3,ENRGY 3 AGF, High Load Fasteners 12-inch o.c.within 6- type B,Grade ENRGY 3 CGF,ENRGY 3 25 PSI, JM TPO 45,60,72 (steel or concrete)or inch wide laps spaced 80 steel or ENRGY 3 25 PSI AGF,ENRGY 3 25 Prelim. or 80,JM TPO JM Structural Concrete SC 47 min. 2,500 psi PSI CGF,JM ISO 3,ValuTherm, attached Reflexsa(10 ft Deck Fasteners seal114 inch o.c. Laps -37.5 A 3/4 structural ValuTherm AGF,ValuTherm CGF, sheet) (concrete only)with sealed with tsi inch concrete ValuTherm 25 PSI AGF,ValuTherm High Load Seam Plates heat weld outside lap 25 PSI CGF,any combination RECEIVED Page 20of34 04/23/2018 ASPEN BUILDING DEPARTMENT TABLE 2C: STEEL OR CONCRETE DECKS- NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D:INSULATED,MECHANICALLY ATTACHED ROOF COVER Fire Rating Insulation Roof Cover UL790/E108 System Deck MDP Max No. (See Note 1) (psf) Type Attach Membrane Fasteners Attachment Class Incline (in.) Min. 1.5-inch thick,one or more Extra High Load Min.22 ga., layers,ENRGY 3,ENRGY 3 AGF, Fasteners(steel only) 12-inch o.c.within 6 type B,Grade ENRGY 3 CGF,ENRGY 3 25 PSI, JM TPO 45,60,72 or JM Structural inch wide laps spaced 80 steel or ENRGY 3 25 PSI AGF,ENRGY 3 25 Prelim. or 80,JM TPO SC-48 min. 2,500 psi PSI CGF,JM ISO 3,ValuTherm, attached Reflexsa(8 ft Concrete Deck 90-inch o.c. Laps -45.0 A 3/4 structural ValuTherm AGF,ValuTherm CGF, sheet) Fasteners(concrete sealed with 1.5-inch concrete ValuTherm 25 PSI AGF,ValuTherm only)with Extra High heat weld outside lap 25 PSI CGF,any combination Load Seam Plates Min. 1.5-inch thick,one or more Min.22 ga., layers,ENRGY 3,ENRGY 3 AGF, High Load Fasteners 6-inch o.c.within 6 type B,Grade ENRGY 3 CGF,ENRGY 3 25 PSI, JM TPO 45,60,72 (steel or concrete)or inch wide laps spaced 80 steel or ENRGY 3 25 PSI AGF,ENRGY 3 25 Prelim. or 80,JM TPO JM Structural Concrete SC-49 -45.0 A 3/4 min. 2,500 psi PSI CGF,JM ISO 3,ValuTherm, attached Reflexsa(10 ft Deck Fasteners 114-inch o.c. Laps structural ValuTherm AGF,ValuTherm CGF, sheet) (concrete only)with sealed with 1.5-inch concrete ValuTherm 25 PSI AGF,ValuTherm High Load Seam Plates heat weld outside lap 25 PSI CGF,any combination Min. 1.5-inch thick,one or more Extra High Load Min.22 ga., layers,ENRGY 3,ENRGY 3 AGF, Fasteners(steel only) 12-inch o.c.within 6 type B,Grade ENRGY 3 CGF,ENRGY 3 25 PSI, JM TPO 45,60,72 or JM Structural inch wide laps spaced 80 steel or ENRGY 3 25 PSI AGF,ENRGY 3 25 Prelim. or 80,JM TPO SC-50 min. 2,500 psi PSI CGF,JM ISO 3,ValuTherm, attached Reflexsa(10 ft Concrete Deck 114-inch o.c. Laps -45.0 A 3/4 structural ValuTherm AGF,ValuTherm CGF, sheet) Fasteners(concrete sealed with 1.5-inch concrete ValuTherm 25 PSI AGF,ValuTherm only)with Extra High heat weld outside lap 25 PSI CGF,any combination Load Seam Plates Min. 1.5-inch thick,one or more Extra High Load Min.22 ga., layers,ENRGY 3,ENRGY 3 AGF, Fasteners(steel only) 6-inch o.c.within 6- type B,Grade ENRGY 3 CGF,ENRGY 3 25 PSI, JM TPO 45,60,72 or JM Structural inch wide laps spaced 80 steel or ENRGY 3 25 PSI AGF,ENRGY 3 25 Prelim. or 80,JM TPO SC 51 min. 2,500 psi PSI CGF,JM ISO 3,ValuTherm, attached Reflexsa(10 ft Concrete Deck 114-inch o.c. Laps -52.5 A 3/4 structural ValuTherm AGF,ValuTherm CGF, sheet) Fasteners(concrete sealed with 1.5-inch concrete ValuTherm 25 PSI AGF,ValuTherm only)with Extra High heat weld outside lap 25 PSI CGF,any combination Load Seam Plates Min. 1.5-inch thick,one or more Min.22 ga., layers,ENRGY 3,ENRGY 3 AGF, High Load Fasteners 6-inch o.c.within 6- type B,Grade ENRGY 3 CGF,ENRGY 3 25 PSI, JM TPO 45,60,72 (steel or concrete)or inch wide laps spaced 80 steel or ENRGY 3 25 PSI AGF,ENRGY 3 25 Prelim. or 80,JM TPO JM Structural Concrete SC-52 min. 2,500 psi PSI CGF,JM ISO 3,ValuTherm, attached Reflexsa(8 ft Deck Fasteners 90-inch o.c. Laps -52.5 A 3/4 structural ValuTherm AGF,ValuTherm CGF, sheet) (concrete only)with sealed with 1.5-inch concrete ValuTherm 25 PSI AGF,ValuTherm High Load Seam Plates heat weld outside lap 25 PSI CGF,any combination RECEIVED Page 21 of 34 04/23/2018 ASPEN BUILDING DEPARTMENT TABLE 3A-1: CONCRETE DECKS-NEW CONSTRUCTION or REROOF(Tear-Off) SYSTEM TYPE A-1A:BONDED INSULATION,BONDED ROOF COVER Fire Rating Base Insulation Layer Top Insulation Layer Roof Cover UL790/E108 System Roof Deck MDP Primer Max No. (psf) Type Attach Type Attach Type Attach Class Incline (in.) JM TPO APPLICATIONS: Min. 1.5-inch ENRGY 3,ENRGY 3 AGF,ENRGY 3 CGF,ENRGY 3 25 PSI,ENRGY 3 25 PSI (Optional)Min. JM TPO 45,60, JM TPO C-1 Min. 2,500 psi None AGF,ENRGY 3 25 PSI CGF,JM JM UIA 0.25-inch JM UTA 72 or 80,JM MA-WB,JM -75.0 A 1/2 concrete ISO 3,ValuTherm,ValuTherm DensDeck or TPO Reflexsa TPO MA-SB AGF,ValuTherm CGF, Invinsa ValuTherm 25 PSI AGF, ValuTherm 25 PSI CGF Min. 1.5-inch ENRGY 3,ENRGY 3 AGF,ENRGY 3 CGF,ENRGY 3 25 PSI,ENRGY 3 25 PSI JM TPO Min. 2,500 psi AGF,ENRGY 3 25 PSI CGF,JM Min. 0.25-inch JM TPO 45,60, MA-WB or C-2 concrete None ISO 3,ValuTherm,ValuTherm JM UIA Invinsa JM UIA 72 or 80,JM JM TPO -112.5 A 1/2 AGF,ValuTherm CGF, TPO Reflexsa MA-SB ValuTherm 25 PSI AGF, ValuTherm 25 PSI CGF Min. 1.5-inch ENRGY 3,ENRGY 3 AGF,ENRGY 3 CGF,ENRGY JM TPO A 1/2 3 25 PSI,ENRGY 3 25 PSI MA-SB Min. 2,500 psi AGF,ENRGY 3 25 PSI CGF,JM (Optional) JM TPO 45,60, C3 concrete None ISO 3,ValuTherm,ValuTherm JM UTA Additional layers of JM UTA 72 or 80,JM -217.5 AGF,ValuTherm CGF, base insulation TPO Reflexsa JM TPO MA-LVOC A 3/4 ValuTherm 25 PSI AGF, ValuTherm 25 PSI CGF Min. 1.5-inch ENRGY 3,ENRGY 3 Min. 1.5-inch ENRGY 3,ENRGY AGF,ENRGY 3 CGF, 3 AGF,ENRGY 3 CGF, ENRGY ENRGY 3 25 PSI, 3 25 PSI,ENRGY 3 25 PSI ENRGY 3 25 PSI AGF,ENRGY 3 25 PSI CGF,JM AGF,ENRGY 3 25 JM TPO 45,60, Min. 2,500 psi JM UTA- JM UT JM TPO C 4 concrete None ISO 3,ValuTherm,ValuTherm TWO-PART PSI CGF,JM ISO 3, PART 72 or 80,JM MA-LVOC -330.0 A 3/4 AGF,ValuTherm CGF, ValuTherm, TPO Reflexsa ValuTherm 25 PSI AGF, ValuTherm AGF, ValuTherm 25 PSI CGF, ValuTherm CGF, Invinsa Foam ValuTherm 25 PSI AGF,ValuTherm 25 PSI CGF Min. 1.5-inch ENRGY 3, ENRGY 3 AGF,ENRGY 3 CGF, ]M TPO ENRGY 3 25 PSI,ENRGY 3 25 MA-WB,JM A 1/2 PSI AGF,ENRGY 3 25 PSI JM TPO 45,60, TPO MA-SB Min. 2,500 psi JM UTA- Min. 1.5-inch JM UTA-TWO- C-5 concrete None CGF,JM ISO 3,ValuTherm, TWO-PART Invinsa Foam PART 72 or 80,JM -330.0 ValuTherm AGF,ValuTherm TPO Reflexsa CGF,ValuTherm 25 PSI AGF, JM TPO A 3/4 ValuTherm 25 PSI CGF, MA-LVOC q \ Invinsa Foam RECEIVED Page22of34 04/23/2018 ASPEN BUILDING DEPARTMENT TABLE 3A-1: CONCRETE DECKS-NEW CONSTRUCTION or REROOF(Tear-Off) SYSTEM TYPE A-1A:BONDED INSULATION,BONDED ROOF COVER Fire Rating Base Insulation Layer Top Insulation Layer Roof Cover UL790/E108 System Roof Deck MDP Primer Max No. Type Attach Type Attach Type Attach (Psf) Class Incline (in.) Min. 1.5-inch ENRGY 3,ENRGY 3 AGF,ENRGY 3 CGF,ENRGY 3 25 PSI,ENRGY 3 25 PSI (Optional)Min. JM UTA- JM TPO 45,60, JM TPO Min. 2,500 psi AGF,ENRGY 3 25 PSI CGF,JM 0.25-inch JM UIA-TWO- C-6 concrete None ISO 3,ValuTherm,ValuTherm TWO-PART DensDeck or PART OR JM UTA 72 or 80,JM MA-WB,JM -105.0 A 1/2 AGF,ValuTherm CGF, OR JM UTA Invinsa TPO Reflexsa TPO MA-SB ValuTherm 25 PSI AGF, ValuTherm 25 PSI CGF Min. 1.5-inch ENRGY 3,ENRGY 3 AGF,ENRGY 3 CGF,ENRGY 3 25 PSI,ENRGY 3 25 PSI JM TPO JM TPO 45,60, C-7 Min. 2,500 psi None AGF,ENRGY 3 25 PSI CGF,JM JM UTA- Min. 0.25-inch JM WA-TWO- 72 or 80,JM MA-WE or -105.0 A 1/2 concrete ISO 3,ValuTherm,ValuTherm TWO-PART Invinsa PART JM TPO TPO Reflexsa AGF,ValuTherm CGF, MA-SB ValuTherm 25 PSI AGF, ValuTherm 25 PSI CGF Min. 1.5-inch ENRGY 3,ENRGY JM TPO 3 AGF,ENRGY 3 CGF,ENRGY MA-WB,JM A 1/2 3 25 PSI,ENRGY 3 25 PSI Min. 0.25-inch TPO MA-SB Min. 2,500 psi AGF,ENRGY 3 25 PSI CGF,JM JM UTA- SECUROCK JM UTA-TWO JM TPO 45,60, C 8 None 72 or 80,JM -247.5 concrete ISO 3,ValuTherm,ValuTherm TWO-PART Gypsum-Fiber Roof PART TPO Reflexsa JM TPO AGF,ValuTherm CGF, Board A 3/4 ValuTherm 25 PSI AGF, MA-LVOC ValuTherm 25 PSI CGF Min. 1.5-inch ENRGY 3,ENRGY JM TPO 3 AGF,ENRGY 3 CGF,ENRGY MA-WB,JM A 1/2 3 25 PSI,ENRGY 3 25 PSI Min. 0.25-inch TPO MA-SB Min. 2,500 psi AGF,ENRGY 3 25 PSI CGF,JM SECUROCK JM TPO 45,60, C 9 None JM-RSUA JM-RSUA 72 or 80,JM -247.5 concrete ISO 3,ValuTherm,ValuTherm Gypsum-Fiber Roof TPO Reflexsa ]M TPO AGF,ValuTherm CGF, Board A 3/4 ValuTherm 25 PSI AGF, MA-LVOC ValuTherm 25 PSI CGF Min. 1.5-inch ENRGY 3,ENRGY 3 AGF,ENRGY 3 CGF,ENRGY 3 25 PSI,ENRGY 3 25 PSI (Optional)Min. JM TPO 45,60, JM TPO C 10 Min. 2,500 psi None AGF,ENRGY 3 25 PSI CGF,JM JM-OSFA 0.25-inch JM OSFA 72 or 80,JM MA WB,JM -75.0 A 1/2 concrete ISO 3,ValuTherm,ValuTherm DensDeck or TPO Reflexsa TPO MA-SB AGF,ValuTherm CGF, Invinsa ValuTherm 25 PSI AGF, ValuTherm 25 PSI CGF RECEIVED Page23of34 04/23/2018 ASPEN BUILDING DEPARTMENT TABLE 3A-1: CONCRETE DECKS-NEW CONSTRUCTION or REROOF(Tear-Off) SYSTEM TYPE A-1A:BONDED INSULATION,BONDED ROOF COVER Fire Rating Base Insulation Layer Top Insulation Layer Roof Cover UL790/E108 System Roof Deck Primer MDP Max No. Type Attach Type Attach Type Attach (Psf) Class Incline (in.) Min. 1.5-inch ENRGY 3,ENRGY JM TPO 3 AGF,ENRGY 3 CGF,ENRGY MA-WB,JM A 1/2 3 25 PSI,ENRGY 3 25 PSI Min. 0.25-inch TPO MA-SB Min. 2,500 psi AGF,ENRGY 3 25 PSI CGF,JM SECUROCK JM TPO 45,60, C 11 None JM-OSFA JM-OSFA 72 or 80,JM -247.5 concrete ISO 3,ValuTherm,ValuTherm Gypsum-Fiber Roof TPO Reflexsa JM TPO AGF,ValuTherm CGF, Board A 3/4 ValuTherm 25 PSI AGF, MA-LVOC ValuTherm 25 PSI CGF JM TPO FB APPLICATIONS: (Optional) JM-RSUA, Min. 2,500 psi Min. 1.5-inch ENRGY 3, JM UTA- UT JM A-TWO JM TPO FB 115 C 12 concrete None ValuTherm TWO-PART Additional layers of PART or 135 12-inch 67.5 A 1/2 base insulation o.c. Min. 1.5-inch ENRGY 3,ENRGY 3 AGF,ENRGY 3 CGF,ENRGY Min. 0.5-inch 3 25 PSI,ENRGY 3 25 PSI Invinsa or JM-RSUA, Min. 2,500 psi None AGF,ENRGY 3 25 PSI CGF,JM JM UTA- UT JM A-TWO JM TPO FB 115 C 13 SECUROCK 12-inch -67.5 A 1/2 concrete ISO 3,ValuTherm,ValuTherm TWO-PART Gypsum-Fiber Roof PART or 135 o.c. AGF,ValuTherm CGF, Board ValuTherm 25 PSI AGF, ValuTherm 25 PSI CGF Min. 2,500 psi Min. 1.5-inch ENRGY 3, (Optional) JM TPO FB 115 JM-RSUA, C-14 concrete None ValuTherm JM-RSUA Additional layers of JM-RSUA or 135 12-inch -67.5 A 1/2 base insulation o.c. Min. 1.5-inch ENRGY 3,ENRGY 3 AGF,ENRGY 3 CGF,ENRGY Min. 0.5-inch 3 25 PSI,ENRGY 3 25 PSI Invinsa or JM-RSUA, C 15 Min. 2,500 psi None AGF,ENRGY 3 25 PSI CGF,JM JM-RSUA SECUROCK JM-RSUA JM TPO FB 115 12-inch -67.5 A 1/2 concrete ISO 3,ValuTherm,ValuTherm or 135 AGF,ValuTherm CGF, Gypsum-Fiber Roof o.c. ValuTherm 25 PSI AGF, Board ValuTherm 25 PSI CGF Min. 1.5-inch ENRGY 3,ENRGY 3 AGF,ENRGY 3 CGF,ENRGY 3 25 PSI,ENRGY 3 25 PSI (Optional) C 16 Min. 2,500 psi ASTM D41 AGF,ENRGY 3 25 PSI CGF,JM HA Additional layers of HA JM TPO FB 115 JM TPO -105.0 A 1/2 concrete ISO 3,ValuTherm,ValuTherm base insulation or 135 MA-WB AGF,ValuTherm CGF, ValuTherm 25 PSI AGF, ValuTherm 25 PSI CGF Min. 1.5-inch ENRGY 3,ENRGY 3 AGF,ENRGY 3 CGF,ENRGY 3 25 PSI,ENRGY 3 25 PSI Min. 0.25-inch Min. 2,500 psi AGF,ENRGY 3 25 PSI CGF,JM SECUROCK JM TPO FB 115 JM TPO C-17 concrete ASTM D41 ISO 3,ValuTherm,ValuTherm HA Gypsum-Fiber Roof HA or 135 MA-WB -105.0 A 2 AGF,ValuTherm CGF, Board ValuTherm 25 PSI AGF, /� ValuTherm 25 PSI CGF RECEIVED Page24of34 04/23/2018 ASPEN BUILDING DEPARTMENT TABLE 3A-1: CONCRETE DECKS-NEW CONSTRUCTION or REROOF(Tear-Off) SYSTEM TYPE A-1A:BONDED INSULATION,BONDED ROOF COVER Fire Rating Base Insulation Layer Top Insulation Layer Roof Cover UL790/E108 System Roof Deck MDP Primer Max No. (psf) Type Attach Type Attach Type Attach Class Incline (in.) Min. 1.5-inch ENRGY 3,ENRGY 3 AGF,ENRGY 3 CGF,ENRGY 3 25 PSI,ENRGY 3 25 PSI (Optional) Min. 2,500 psi AGF,ENRGY 3 25 PSI CGF,JM JM TPO FB 115 JM TPO C 18 concrete None ISO 3,ValuTherm,ValuTherm JM UIA Additional layers of JM UIA or 135 MA-WB 105.0 A 1/2 AGF,ValuTherm CGF, base insulation ValuTherm 25 PSI AGF, ValuTherm 25 PSI CGF Min. 2-inch ENRGY 3,ENRGY 3 AGF,ENRGY 3 CGF,ENRGY 3 25 PSI,ENRGY 3 25 PSI AGF, Min. 0.25-inch Min. 2,500 psi ENRGY 3 25 PSI CGF,JM ISO SECUROCK JM TPO FB 115 JM TPO C 19 concrete None 3,ValuTherm,ValuTherm JM UIA Gypsum-Fiber Roof JM UIA or 135 MA-WB 105.0 A 2 AGF,ValuTherm CGF, Board ValuTherm 25 PSI AGF, ValuTherm 25 PSI CGF Min. 1.5-inch ENRGY 3,ENRGY 3 AGF,ENRGY 3 CGF,ENRGY 3 25 PSI,ENRGY 3 25 PSI (Optional) Min. 2,500 psi AGF,ENRGY 3 25 PSI CGF,JM JM UIA- Additional JM UTA-TWO JM TPO FB 115 ]M TPO C 20 concrete None ISO 3,ValuTherm,ValuTherm TWO-PART layers of PART or 135 MA-WB 105.0 A 1/2 AGF,ValuTherm CGF, base insulation ValuTherm 25 PSI AGF, ValuTherm 25 PSI CGF Min. 2-inch ENRGY 3,ENRGY 3 AGF,ENRGY 3 CGF,ENRGY 3 25 PSI,ENRGY 3 25 PSI AGF, Min. 0.25-inch Min. 2,500 psi ENRGY 3 25 PSI CGF,JM ISO JM UTA- SECUROCK JM WA-TWO- JM TPO FB 115 JM TPO C 21 concrete None 3,ValuTherm,ValuTherm TWO-PART Gypsum-Fiber Roof PART or 135 MA-WB 105.0 A 2 AGF,ValuTherm CGF, Board ValuTherm 25 PSI AGF, ValuTherm 25 PSI CGF Min. 1.5-inch ENRGY 3,ENRGY 3 AGF,ENRGY 3 CGF,ENRGY 3 25 PSI,ENRGY 3 25 PSI (Optional) Min. 2,500 psi AGF,ENRGY 3 25 PSI CGF,JM JM TPO FB 115 JM TPO C 22 concrete None ISO 3,ValuTherm,ValuTherm JM-OSFA Additional layers of JM-OSFA or 135 MA-WB -105.0 A 1/2 AGF,ValuTherm CGF, base insulation ValuTherm 25 PSI AGF, ValuTherm 25 PSI CGF Min. 2-inch ENRGY 3,ENRGY 3 AGF,ENRGY 3 CGF,ENRGY 3 25 PSI,ENRGY 3 25 PSI AGF, Min. 0.25-inch Min. 2,500 psi ENRGY 3 25 PSI CGF,JM ISO SECUROCK JM TPO FB 115 JM TPO C-23 concrete None 3,ValuTherm,ValuTherm JM-OSFA Gypsum-Fiber Roof JM-OSFA or 135 MA-WB 105.0 A 2 AGF,ValuTherm CGF, Board ValuTherm 25 PSI AGF, ValuTherm 25 PSI CGF RECEIVED Page25of34 04/23/2018 ASPEN BUILDING DEPARTMENT TABLE 3A-2: CONCRETE DECKS-NEW CONSTRUCTION or REROOF(Tear-Off) SYSTEM TYPE A-1B:BONDED TEMP ROOF,BONDED INSULATION,BONDED ROOF COVER Temporary Roof Base Insulation Layer Top Insulation Layer Roof Cover Fire Rating System Deck UL790/E108 No (See Note Primer MDf Max 1) Type Attach Type Attach Type Attach Type Attach (p Class Incline (in.) JM TPO FB APPLICATIONS: JM SA Min. 1.5-inch (Optional) JM-RSUA, Min. 2,500 JM Vapor Self- JM UTA- Additional JM UTA- JM TPO FB C-24 Primer ENRGY 3, 12-inch -67.5 A 1/2 psi concrete Low VOC Barrier SA Adhered ValuTherm TWO-PART layers of base TWO-PART 115 or 135 o.c. insulation Min. 1.5-inch ENRGY 3, ENRGY 3 AGF, ENRGY 3 CGF, ENRGY 3 25 Min.0.5-inch PSI,ENRGY 3 Invinsa or 25 PSI JM SA SECUROCK AGF, Min. 2,500 JM Vapor Self- ENRGY 3 25 PSI JM UTA- JM UTA- JM TPO FB JM-RSUA, C-25 Primer Gypsum-Fiber 12-inch -67.5 A 1/2 psi concrete Low VOC Barrier SA Adhered CGF,JM ISO 3, TWO-PART Roof Board or TWO-PART 115 or 135 o.c. ValuTherm, min. 1.5-inch ValuTherm AGF, Invinsa Foam ValuTherm CGF, ValuTherm 25 PSI AGF, ValuTherm 25 PSI CGF (Optional) JM SA Min. 1.5-inch JM-RSUA, Min. 2,500 JM Vapor Self- Additional JM TPO FB C-26 Primer ENRGY 3, JM-RSUA JM-RSUA 12-inch -67.5 A 1/2 psi concrete Low VOC Barrier SA Adhered ValuTherm layers of base 115 or 135 o.c. insulation Min. 1.5-inch ENRGY 3, ENRGY 3 AGF, ENRGY 3 CGF, ENRGY 3 25 PSI,ENRGY 3 25 PSI AGF, JM SA Invinsa or Min.0.5-inch Min. 2,500 JM Vapor Self- ENRGY 3 25 PSI JM TPO FB JM-RSUA, C-27 Primer JM-RSUA SECUROCK JM-RSUA 12-inch -67.5 A 1/2 psi concrete Low VOC Barrier SA Adhered CGF,JM ISO 3, 115 or 135 Gypsum-Fiber o.c. ValuTherm, Roof Board ValuTherm AGF, ValuTherm CGF, ValuTherm 25 PSI AGF, ValuTherm 25 PSI CGF RECEIVED Page26of34 04/23/2018 ASPEN BUILDING DEPARTMENT TABLE 4A: LIGHTWEIGHT CONCRETE DECKS - NEW CONSTRUCTION OR RE ROOF (TEAR-OFF) SYSTEM TYPE F: NON-INSULATED,BONDED ROOF COVER Deck(See Note 1) Roof Cover Fire Rating System MDP UL790/E108 Max No. Structural LWC Type Attach (psf) Class Incline (in.) Min. 379 psi, min. 2"thick Concrecel Concrete, with JM TPO 45, 60, 72 or LWC-1 Min. 2,500 psi concrete optional 1"thick, 1.0 pcf EPS holey board and surfacing 80,JM TPO Reflexsa JM TPO MA-LVOC -285.0 A 3/4 of Concrecel Curing Compound. Min. 350 psi, min. 2"thick Celcore MF Cellular Concrete LWC-2 Min. 2,500 psi concrete with Celcore HS Rheology Modifying Admixture, with JM TPO 45, 60, 72 or JM TPO MA-LVOC -367.5 A 3/4 optional 1"thick, 1.0 pcf EPS holey board and surfacing 80,JM TPO Reflexsa of Celcore PVA Curing Compound. RECEIVED Page27of34 04/23/2018 ASPEN BUILDING DEPARTMENT TABLE 5A: GYPSUM DECKS- REROOF (TEAR-OFF) SYSTEM TYPE A-1:BONDED INSULATION,BONDED ROOF COVER Fire Rating Base Insulation Layer Top Insulation Layer Roof Cover UL790/E108 System Deck MDP Max No. (See Note 1) Type Attach Type Attach Type Attach (psf) Class Incline (in.) JM TPO APPLICATIONS: Min. 1.5-inch ENRGY 3, ENRGY 3 AGF,ENRGY 3 CGF,ENRGY 3 25 PSI, Existing poured ENRGY 3 25 PSI AGF, (Optional)Min.0.25- JM TPO 45, JM TPO MA-WB, G-1 gypsum or ENRGY 3 25 PSI CGF,JM JM UTA-TWO- inch DensDeck or JM UTA-TWO- 60,72 or 80, JM TPO MA-SB gypsum 105.0 A 1/2 plank ISO 3,ValuTherm, PART Invinsa or min. 1.5-inch PART JM TPO or TACC FA- ValuTherm AGF, Invinsa Foam Reflexsa 141 ValuTherm CGF, ValuTherm 25 PSI AGF, ValuTherm 25 PSI CGF Min. 1.5-inch ENRGY 3, ENRGY 3 AGF,ENRGY 3 CGF,ENRGY 3 25 PSI, ENRGY 3 25 PSI AGF, JM TPO 45, JM TPO MA-SB, Existing poured (Optional)Additional G-2 gypsum or ENRGY 3 25 PSI CGF,JM JM UTA-TWO- JM UTA-TWO- 60,72 or 80, JM TPO MA- gypsum ISO 3,ValuTherm, PART layers of base PART JM TPO LVOC or TACC 112.5 A 1/2 plank ValuTherm AGF, insulation Reflexsa FA-141 ValuTherm CGF, ValuTherm 25 PSI AGF, ValuTherm 25 PSI CGF JM TPO FB APPLICATIONS: Min. 1.5-inch ENRGY 3, ENRGY 3 AGF,ENRGY 3 CGF,ENRGY 3 25 PSI, (Optional)Additional Existing poured ENRGY 3 25 PSI AGF, layers of base ENRGY 3 25 PSI CGF,JM JM UTA-TWO- insulation or Min.0.25- JM UTA-TWO- JM TPO FB G-3 gypsum or gypsum ISO 3,ValuTherm, PART inch SECUROCK PART 115 or 135 JM TPO MA-WB -105.0 A 1/2 plank ValuTherm AGF, G ypsum Fiber Roof ValuTherm CGF, Board ValuTherm 25 PSI AGF, ValuTherm 25 PSI CGF RECEIVED Page28of34 04/23/2018 ASPEN BUILDING DEPARTMENT TABLE 6A: RECOVER APPLICATIONS SYSTEM TYPE A:BONDED INSULATION,BONDED ROOF COVER Base Insulation Layer Top Insulation Layer Roof Cover Fire Rating System MDP UL790/E108 No. Substrate (psf) Max Type Attach Type Attach Type Attach Class Incline (in.) JM TPO APPLICATIONS: Min. 1.5-inch ENRGY 3, ENRGY 3 AGF,ENRGY 3 CGF,ENRGY 3 25 PSI, ENRGY 3 25 PSI AGF, ENRGY 3 25 PSI CGF, (Optional)Min. 0.25- JM TPO 45,60, JM TPO R-1 Existing asphaltic BUR JM ISO 3,ValuTherm, JM UTA inch DensDeck or JM UTA 72 or 80,JM MA-WB,JM -75.0 A 1/2 ValuTherm AGF, Invinsa TPO Reflexsa TPO MA-SB ValuTherm CGF, ValuTherm 25 PSI AGF, ValuTherm 25 PSI CGF Min. 0.25 inch JM TPO 45,60, JM TPO R-2 Existing asphaltic BUR DensDeck or Invinsa JM UTA N/A N/A 72 or 80,JM MA-WB,JM -75.0 A 3/4 TPO Reflexsa TPO MA-SB Min. 1.5-inch ENRGY 3, JM TPO ENRGY 3 AGF,ENRGY 3 A 172 CGF,ENRGY 3 25 PSI, MA-SB, ENRGY 3 25 PSI AGF, ENRGY 3 25 PSI CGF, (Optional)Additional JM TPO 45,60, R-3 Existing asphaltic BUR JM UTA layers of base JM UTA 72 or 80,JM -157.5 JM ISO 3,ValuTherm, insulation TPO Reflexsa JM TPO ValuTherm AGF, A 3/4 MA-LVOC ValuTherm CGF, ValuTherm 25 PSI AGF, ValuTherm 25 PSI CGF Min. 1.5-inch ENRGY 3, ENRGY 3 AGF,ENRGY 3 CGF,ENRGY 3 25 PSI, ENRGY 3 25 PSI AGF, Min. 0.25-inch JM TPO 45,60, JM TPO R-4 Existing asphaltic BUR ENRGY 3 25 PSI CGF, JM UIA-TWO-PART DensDeck or Invinsa JM UTA-TWO-PART 72 or 80,JM MA-WB,JM -105.0 A 3/4 3M ISO 3,ValuTherm, or min. 1.5-inch ValuTherm AGF, Invinsa Foam TPO Reflexsa TPO MA-SB ValuTherm CGF, ValuTherm 25 PSI AGF, ValuTherm 25 PSI CGF Min. 0.25-inch 3M TPO 45, 3M TPO R 5 Existing asphaltic DensDeck or Invinsa JM UIA-TWO-PART N/A N/A 60,72 or 80, MA-WB, -105.0 A 3/4 BUR or min. 1.5-inch 3M TPO 3M TPO Invinsa Foam Reflexsa MA-SB RECEIVED Page29of34 04/23/2018 ASPEN BUILDING DEPARTMENT TABLE 6A: RECOVER APPLICATIONS SYSTEM TYPE A:BONDED INSULATION,BONDED ROOF COVER Fire Rating Base Insulation Layer Top Insulation Layer Roof Cover UL790/E108 System MDP Max No. Substrate Type Attach Type Attach Type Attach (psf) Class Incline (in.) Min. 1.5-inch ENRGY 3, ENRGY 3 AGF,ENRGY 3 JM TPO CGF,ENRGY 3 25 PSI, MA-SB A 1/2 ENRGY 3 25 PSI AGF, (Optional)Additional JM TPO 45,60, R-6 Existing asphaltic ENRGY 3 25 PSI CGF, 3M UTA-TWO-PART layers of base JM UTA-TWO-PART 72 or 80,JM -120.0 BUR JM ISO 3,ValuTherm, insulation TPO Reflexsa ValuTherm AGF, JM TPO ValuTherm CGF, MA-LVOC A 3/4 ValuTherm 25 PSI AGF, ValuTherm 25 PSI CGF Min. 1.5-inch ENRGY 3, ENRGY 3 AGF,ENRGY 3 CGF,ENRGY 3 25 PSI, ENRGY 3 25 PSI AGF, (Optional)Min. 0.25- JM TPO 45,60, JM TPO R 7 Existing asphaltic ENRGY 3 25 PSI CGF, JM-OSFA inch DensDeck or JM-OSFA 72 or 80,JM MA-WB,JM -75.0 A 3/4 BUR JM ISO 3,ValuTherm, Invinsa TPO Reflexsa TPO MA-SB ValuTherm AGF, ValuTherm CGF, ValuTherm 25 PSI AGF, ValuTherm 25 PSI CGF 3M TPO Existing asphaltic Min. 0.25-inch JM TPO 45,60, MA-WB,JM R-8 BUR DensDeck or Invinsa JM-OSFA N/A N/A 72 or 80,JM TPO MA-SB -75.0 A 3/4 TPO Reflexsa or TACC FA-141 3M TPO FB APPLICATIONS: Min. 1.5-inch ENRGY 3, ENRGY 3 AGF, ENRGY 3 CGF,ENRGY 3 25 PSI, (Optional)Additional ENRGY 3 25 PSI AGF, layers of base Existing asphaltic ENRGY 3 25 PSI CGF, insulation or Min. JM TPO FB 115 JM TPO R 9 BUR JM ISO 3,ValuTherm, 3M UIA 0.25-inch SECUROCK JM UIA or 135 MA-WB -105.0 A 1/2 ValuTherm AGF, Gypsum-Fiber Roof ValuTherm CGF, Board ValuTherm 25 PSI AGF, ValuTherm 25 PSI CGF Min. 1.5-inch ENRGY 3, ENRGY 3 AGF,ENRGY 3 CGF,ENRGY 3 25 PSI, (Optional)Additional ENRGY 3 25 PSI AGF, layers of base Existing asphaltic ENRGY 3 25 PSI CGF, insulation or Min. JM TPO FB 115 JM TPO R-10 BUR JM ISO 3,ValuTherm, JM UIA-TWO-PART 0.25-inch SECUROCK JM UIA-TWO-PART or 135 MA-WB -105.0 A 1/2 ValuTherm AGF, Gypsum-Fiber Roof ValuTherm CGF, Board ValuTherm 25 PSI AGF, ValuTherm 25 PSI CGF RECEIVED Page 30of34 04/23/2018 ASPEN BUILDING DEPARTMENT TABLE 6B: RECOVER OVER EXISTING METAL PANEL ROOF SYSTEM TYPE C-2: MECHANICALLY ATTACHED INSULATION,PLATE-BONDED ROOF COVER Attachment Fire Rating UL790/E10S System No. Deck(See Note 1) Insulation Layer Roof Cover MDP Max Fasteners Density (p ) Class Incline (in.) ENRGY 3,ENRGY 3 AGF,ENRGY 3 CGF, ENRGY 3 25 PSI,ENRGY 3 25 PSI AGF, Preliminary Insulation preliminarily ENRGY 3 25 PSI CGF,JM ISO 3, Securement: secured with JM TPO bonded to JM TPO Existing wood,steel or ValuTherm,ValuTherm AGF,ValuTherm UltraFast fasteners/plates in Note 2. RhinoPlates with Rhinobond concrete deck atop min. CGF,ValuTherm 25 PSI AGF,ValuTherm Plate-Bonded JM Purlin Fasteners with Plate bonding tool at 6 R-11 16 ga. (0.0598")purlins 25 PSI CGF between ribs or over panels Securement: JM TPO Rhino Plates seconds per plate so tool -45.0 A 1/2 or steel supports spaced of existing non-structural metal roof JM Purlin spaced 6-inch o.c.at reaches 400°F and cooled max. 5 ft o.c. followed by additional base layer or Min. Fasteners with every-other structural with RhinoBond Cooling 0.25-inch DensDeck,Invinsa or JM TPO steel support(max. 120- Clamps SECUROCK Gypsum-Fiber Roof Board or RhinoPlates inch o.c.) min. 7/16-inch OSB ENRGY 3,ENRGY 3 AGF,ENRGY 3 CGF, ENRGY 3 25 PSI,ENRGY 3 25 PSI AGF, Preliminary Insulation preliminarily ENRGY 3 25 PSI CGF,JM ISO 3, Securement: secured with JM TPO bonded to JM TPO Existing wood,steel or ValuTherm,ValuTherm AGF,ValuTherm UltraFast fasteners/plates in Note 2. RhinoPlates with Rhinobond concrete deck atop min. CGF,ValuTherm 25 PSI AGF,ValuTherm Plate-Bonded JM Purlin Fasteners with Plate bonding tool at 6 R-12 16 ga. (0.0598")purlins 25 PSI CGF between ribs or over panels Securement: JM TPO Rhino Plates seconds per plate so tool -45.0 A 1/2 or steel supports spaced of existing non-structural metal roof JM Purlin spaced 18-inch o.c.at reaches 400°F and cooled max. 5 ft o.c. followed by additional base layer or Min. Fasteners with every structural steel with RhinoBond Cooling 0.25-inch DensDeck,Invinsa or JM TPO support(max.60-inch Clamps SECUROCK Gypsum-Fiber Roof Board or RhinoPlates o.c.) min. 7/16-inch OSB ENRGY 3,ENRGY 3 AGF,ENRGY 3 CGF, ENRGY 3 25 PSI,ENRGY 3 25 PSI AGF, Preliminary Insulation preliminarily ENRGY 3 25 PSI CGF,JM ISO 3, Securement: secured with JM TPO bonded to JM TPO Existing wood,steel or ValuTherm,ValuTherm AGF,ValuTherm UltraFast fasteners/plates in Note 2. RhinoPlates with Rhinobond concrete deck atop min. CGF,ValuTherm 25 PSI AGF,ValuTherm Plate-Bonded JM Purlin Fasteners with Plate bonding tool at 6 R-13 16 ga. (0.0598")purlins 25 PSI CGF between ribs or over panels Securement: JM TPO Rhino Plates seconds per plate so tool -67.5 A 1/2 or steel supports spaced of existing non-structural metal roof JM Purlin spaced 12-inch o.c.at reaches 400°F and cooled max. 5 ft o.c. followed by additional base layer or Min. Fasteners with every structural steel with RhinoBond Cooling 0.25-inch DensDeck,Invinsa or JM TPO support(max.60-inch Clamps SECUROCK Gypsum-Fiber Roof Board or RhinoPlates o.c.) min. 7/16-inch OSB ENRGY 3,ENRGY 3 AGF,ENRGY 3 CGF, ENRGY 3 25 PSI,ENRGY 3 25 PSI AGF, Preliminary Insulation preliminarily ENRGY 3 25 PSI CGF,JM ISO 3, Securement: secured with JM TPO bonded to JM TPO Existing wood,steel or ValuTherm,ValuTherm AGF,ValuTherm UltraFast fasteners/plates in Note 2. RhinoPlates with Rhinobond concrete deck atop min. CGF,ValuTherm 25 PSI AGF,ValuTherm Plate-Bonded JM Purlin Fasteners with Plate bonding tool at 6 R-14 16 ga. (0.0598")purlins 25 PSI CGF between ribs or over panels Securement: JM TPO Rhino Plates seconds per plate so tool -120.0 A 1/2 or steel supports spaced of existing non-structural metal roof JM Purlin spaced 6-inch o.c.at reaches 400°F and cooled max. 5 ft o.c. followed by additional base layer or Min. Fasteners with every structural steel with RhinoBond Cooling 0.25-inch DensDeck,Invinsa or JM TPO support(max.60-inch Clamps SECUROCK Gypsum-Fiber Roof Board or RhinoPlates o.c.) min. 7/16-inch OSB RECEIVED Page31 of34 04/23/2018 ASPEN BUILDING DEPARTMENT TABLE 6C: RECOVER OVER EXISTING METAL PANEL ROOF SYSTEM TYPE D: INSULATED, MECHANICALLY ATTACHED ROOF COVER Fire Rating Insulation Roof Cover UL790/E108 System Deck MDP Max No. (See Note 1) Base Layer Top Layer Attach Membrane Fasteners Attachment (psf) Class Incline (in.) ENRGY 3, ENRGY 3 AGF, ENRGY 3 CGF, Additional base ENRGY 3 25 PSI, layer or Min. Fasteners spaced Existing wood, ENRGY 3 25 PSI AGF, 0.25-inch 12-inch o.c. within steel or concrete ENRGY 3 25 PSI CGF, DensDeck, JM TPO 45, JM Purlin 5-inch wide laps deck atop min. 16 JM ISO 3,ValuTherm, Invinsa or Prelim. 60,72 or 80, Fasteners with engage structural R-15 ga. (0.0598") ValuTherm AGF, -37.5 A 1/2 purlins or steel ValuTherm CGF, SECUROCK Attached JM TPO High Load Seam supports spaced supports spaced ValuTherm 25 PSI AGF, Gypsum-Fiber Reflexsa Plates 60-inch o.c. Laps max. 5 ft o.c. ValuTherm 25 PSI CGF Roof Board or sealed with between ribs or over min. 7/16-inch inch heat weld. panels of existing non- OSB structural metal roof ENRGY 3, ENRGY 3 AGF, ENRGY 3 CGF, Additional base ENRGY 3 25 PSI, layer or Min. Fasteners spaced Existing wood, ENRGY 3 25 PSI AGF, 0.25-inch 12-inch o.c. within steel or concrete ENRGY 3 25 PSI CGF, DensDeck, JM TPO 45, JM Purlin 5-inch wide laps deck atop min. 16 JM ISO 3,ValuTherm, Invinsa or Prelim. 60,72 or 80, Fasteners with engage structural R-16 ga. (0.0598") ValuTherm AGF, -45.0 A 1/2 purlins or steel ValuTherm CGF, SECUROCK Attached JM TPO Extra High Load supports spaced supports spaced ValuTherm 25 PSI AGF, Gypsum-Fiber Reflexsa Seam Plates 60-inch o.c. Laps max. 5 ft o.c. ValuTherm 25 PSI CGF Roof Board or sealed with between ribs or over min. 7/16-inch inch heat weld. panels of existing non- OSB structural metal roof ENRGY 3, ENRGY 3 AGF, ENRGY 3 CGF, Additional base ENRGY 3 25 PSI, layer or Min. Fasteners spaced Existing wood, ENRGY 3 25 PSI AGF, 0.25-inch 6-inch o.c. within steel or concrete ENRGY 3 25 PSI CGF, DensDeck, JM TPO 45, JM Purlin 5-inch wide laps deck atop min. 16 JM ISO 3,ValuTherm, Invinsa or Prelim. 60,72 or 80, Fasteners with engage structural R-17 ga. (0.0598") ValuTherm AGF, -82.5 A 1/2 purlins or steel ValuTherm CGF, SECUROCK Attached JM TPO High Load Seam supports spaced supports spaced ValuTherm 25 PSI AGF, Gypsum-Fiber Reflexsa Plates 60-inch o.c. Laps max. 5 ft o.c. ValuTherm 25 PSI CGF Roof Board or sealed with between ribs or over min. 7/16-inch inch heat weld. panels of existing non- OSB structural metal roof I RECEIVED Page32of34 04/23/2018 ASPEN BUILDING DEPARTMENT TABLE 6D: RECOVER APPLICATIONS SYSTEM TYPE F: NON-INSULATED,BONDED ROOF COVER Roof Cover Fire Rating UL790/E108 SyNtoem Substrate(See Notes 1&12) (psf)D Max Type Attach Class Incline (in.) R-18 Existing asphaltic granule surface cap sheet JM TPO FB 115 or 135 JM-RSUA, 12-in. oc -45.0 A 3/4 RECEIVED Page33of34 04/23/2018 ASPEN BUILDING DEPARTMENT ©2014 UL LLC This UL Evaluation Report is not an endorsement or recommendation for use of the subject and/or product described herein. This report is not the UL Listing or UL Classification Report that covers the subject product. The subject product's UL Listing or UL Classification is covered under a separate UL Report. UL disclaims all representations and warranties whether express or implied, with respect to this report and the subject or product described herein. Contents of this report may be based on data that has been generated by laboratories other than UL that are accredited as complying with ISO/IEC Standard 17025 by the International Accreditation Service (IAS) or by any other accreditation body that is a signatory to the International Laboratory Accreditation Cooperation (ILAC) Mutual Recognition Arrangement(MRA). The scope of the laboratory's accreditation shall include the specific type of testing covered in the test report. As the accuracy of any non-UL data is the responsibility of the accredited laboratory, UL does not accept responsibility for the accuracy of this data. RECEIVED Page 34 of 34 04/23/2018 ASPEN BUILDING DEPARTMENT