Loading...
HomeMy WebLinkAboutFile Documents.250 S Original St.0019.2017 (16).ARBK 250 Original #C_BuildingComments_1 Chatelet Unit C permit.pdf(8) Page:A-101 File Name: Chatelet Unit C permit.pdf The upper level bedroom is ELOPDON,�DYEW Subject: PlanCheck labeled "kids room"so is the .,^.�^ Author: nickt basement room. No bedrooms Color: • allowed in the basement without 0� egress or fire sprinkler. 1 . — ' _-_ d Please see attached for the relabeled lower level...please disregard previously labeled room. Note, this room type does not require egress. Please refer to as a sheet to A-101. Page:A-101 T"° This door leads to a dark, File Name: Chatelet Unit C permit.pdf 'o d 7 Subject: PlanCheck enclosed hallway. If it could be Author: nickt rebuilt as a protected exit Color: ■ enclosure, it could count as egress from the bedroom. 61 GaU,Lo The lower does not require egress. ---— Page:A-101 ----------------- ---®--------- =------- File Name: Chatelet Unit C permit.pdf Describe all mechanical i' q Subject: PlanCheck equipment,fuel type, I I�. 1 Author: nickt combustion air requirements, ei ;, and vent routing including ��„Ili Color: • C ii-- terminations.The RCPs show i L .uul ,a marhaniral alcn in nna of tha .L _ �:e Triangle Tube Boiler- Prestige ACV Max 110 MBH o , . —, 55 gallon storage tank H20-Triangle Tube Comfort 55 with 1-1/2"insulation 100 amp service panel for electricity-requires 30" of clear space in front of it per code. Refar to RCP for ventilation diagram. Page:A-101 File Name: Chatelet Unit C permit.pdf The lower level may not have a Subject: PlanCheck bedroom unless an emergency Author: nickt escape and rescue opening is Color: • provided or the entire building is _ r----_-J -'-- - - - sprinklered. This looks like a bedroom. \7 Nick, this is not a bedroom ¶`'- H w Page:A-102 You will be removing drywall for MY LEVEL-PROPOSED W. �, File Name: Chatelet Unit C permit.pdf the asbestos abatement.All abestos abate ant Subject: PlanCheck Author: nickt exterior walls that are exposed -" -" ---" ---- - - Color: • must be filled with insulation if they are not already. 2015 IECC - aimr� - < R503.1.1 4 C:, ,, / = -L, Yes, please refer to annotation for compliant insulated walls. City of Aspen Received 6/6/17 Building Department NEW MECHANICAL ROOM LIGHT Page:A-104 ® NEW PENDANT LIGHTING rixluc File Name: Chatelet Unit C permit.pdf 2015 IECC R404 requires a minimum of 75% of lamps to be a INTERNATIONAL CODE COUNCIL °Erc= Subject: PlanCheck qq,,°n n ^^m ° high efficacy. Fix this on the °r of the ampsI^o °e^,^Installed smog Author: nickt oo cover page as well. Color: • 2015 IECC R404 reqUireS a Minimum of 75%of lamps to be high efficacy.Fix this please see revised cover sheet on the cover page as well. -003 Page:A-711 A.004 File Name: Chatelet Unit C permit.pdf Provide the U-factor of the new A005 Subject: PlanCheck entry door and all exterior ° Author: nickt windows. Maximum 0.28 per Provide the U-factor of A-,°8 the new entry door and A-,,, Ordinance 40, 2016. Provide a all exterior windows a2 Color: • Maximum 0.28 per A-113 window schedule. Ordinance 40,2016. A-202 Provide a window A-203 schedule. A-207 08 A210 Please see attached for the requested U-values. Page: G-000 File Name: Chatelet Unit C permit.pdf Provide an asbestos abatement Subject: PlanCheck clearance letter. Author: nickt Provide an asbestos abatement Color: • clearance letter. Please see attached for the requested clearance letter City of Aspen Received 6/6/17 Building Department