MODEL NO. 60E with mandatory safety screen FRONT
Viewing Area 60" W x 14.75" H 60.75" _
Exterior Dimension 69.25" W x 29" H x 23.25" D
Framing Dimension 72.25" W x 36.25" H x 24.75" D i
Gas Type* Natural or LP/Propane 7.125" _ _
Gas Connection 1/2" pipe 1
On/Off Programmable/thermostatic remote control standard 35.25"
Efficiency Up to 78%
Venting Options Through exterior wall or vertical through roof, 29 14.75"
Must vent 3' vertically before horizontal venting. A
Vent Type Duravent DirectVent Pro 58DVA Must source locally, 7.125" -
not included. 1 1
Fan Thermostat activated 160 c.f.m.
69.25" —a 1
Electric 1 10 V 71.25
BTU input Natural gas 35,000-52,000 BTU/h TOP
1" 69.25" �"
BTU input LP/propane 42,000-52,000 BTU/h 8" 5" 1
Doors/glass Fixed ceramic glass panel
Interior Color Satin Black
Sustained operating gas pressure
parameters: 4.5" - 10.5" w.c. for Natural gas 22.25
1 1 .0" - 13.0" w.c. for LP/propane
Certifications Omni-Test Laboratories ANSI Z21 .88-2014/CSA
.
2.33-2014, CGA 2.17-M91 (R2009),
CSA P.4.1-09 STANDARDS
SIDE
Options Fire Objects A
r.
*Must be specified at time of ordering. Media Tray, required when using fire objects I . I. TNote: This is a high throughput gas ,
appliance and critical attention is 0: 35.25"
needed to size the gas pipes properly.
• 29"
Electric access °
T
both sides 1°
23.25"—
Gas line access both sides