Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
File Documents.1112 Waters Ave.0089.2017 (12).ARBK
ICC EVALUATION Most Widely Accepted and Trusted EVALUATION SERVICE In Cooperation with L. Innovation LJ RESEARCH LABS ICC-ES Evaluation Report ESR-2053 ICC-ES I (800)423-6587 I (562) 699-0543 I www.icc-es.org Reissued 07/2017 This report is subject to renewal 07/2018. DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION SECTION: 07 30 05—ROOFING FELT AND UNDERLAYMENT REPORT HOLDER: GAF 1 CAMPUS DRIVE PARSIPPANY, NEW JERSEY 07054 EVALUATION SUBJECT: VERSASHIELD® FIRE-RESISTANT ROOF DECK PROTECTION AND VERSASHIELDTM UNDERLAYMENT ICC ICC ICC ES c� c pMG LISTED Look for the trusted marks of Conformity! IS\ "2014 Recipient of Prestigious Western States Seismic Policy Council ems (WSSPC)Award in Excellence" A Subsidiary of In ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not s"B`pfe'Red specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a ANSI recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as ACCREDITED ISO/IEC 17065 to any finding or other matter in this report, or as to any product covered by the report. Product Certification Body nurdroicoH #1000 Copyright © 2017 ICC Evaluation Service, LLC. All rights reserved. ICC ESEVALUATION SERVICE Most Widely Accepted and Trusted ICC-ES Evaluation Report ESR-2053 Reissued July 2017 This report is subject to renewal July 2018. www.icc-es.org I (800) 423-6587 I (562) 699-0543 A Subsidiary of the International Code Council° DIVISION: 07 00 00—THERMAL AND MOISTURE 3.0 DESCRIPTION PROTECTION Section: 07 30 05—Roofing Felt and Underlayment VersaShield® Fire Resistant Roof Deck Protection is a resin-bound chopped-glass-fiber substrate, coated on REPORT HOLDER: both sides with a mineral-filled aqueous coating. The underlayment has a weight of 15 pounds per 100 square GAF feet(0.73 kg/m2), and is supplied in rolls. 1 CAMPUS DRIVE 4.0 INSTALLATION PARSIPPANY, NEW JERSEY 07054 (973)628-3000 4.1 General: www.gaf.com VersaShield® Fire-Resistant Roof Deck Protection is installed in accordance with the requirements of the EVALUATION SUBJECT: applicable code, the manufacturer's published installation ® instructions and this report. The manufacturer's published VERSASHIELD® FIRE-RESISTANT ROOF DECK installation instructions are to be available at the jobsite PROTECTION AND VERSASHIELDTM UNDERLAYMENT during the installation. 1.0 EVALUATION SCOPE VersaShield® Fire-Resistant Roof Deck Protection is limited to use over spaced or solid sheathing, or over Compliance with the following codes: existing asphalt shingles, wood shakes or wood shingles • 2012, 2009 and 2006 International Building Code°(IBC) installed on spaced or solid sheathing. Prior to application of the underlayment, the deck surface is to be free of dust • 2012, 2009 and 2006 International Residential Code° and dirt, loose nails and other protrusions. Damaged (IRC) sheathing is to be replaced. The underlayment is applied at • 2013 Abu Dhabi International Building Code(ADIBC)t right angles to the slope of the roof, beginning at the low point of the roof, and is laid with minimum 2-inch (51 mm) tThe ADIBC is based on the 2009 IBC.2009 IBC code sections referenced horizontal and 6-inch (152 mm) vertical lapped joints. It is in this report are the same sections in the ADIBC. attached with a sufficient number of nails, having tin caps Properties evaluated: or 1-inch-diameter (25.4 mm) plastic caps, to hold the underlayment in place until the roof covering is applied, • Physical properties except in areas subject to high winds where the • Fire classification underlayment fastening must comply with the high wind attachment requirements specified in Section 1507 of the 2.0 USES 2012 IBC or Section R905 of the 2012 IRC. The VersaShield® Fire-Resistant Roof Deck Protection underlayment may be bent to a minimum 1/2-inch (previously known as VersaShield® Underlayment) is used (12.7 mm) radius, but is not to be creased. At junctions as an alternative to ASTM D226, Type I or Type II, roofing between the roof deck and vertical surfaces, the underlayment specified in Chapter 15 of the IBC and underlayment is installed a minimum of 3 inches (76 mm) Chapter 9 of the IRC. up the vertical surface. When installed in accordance with Section 4.2.1 of this In areas of the roof required to have an ice barrier under report, VersaShield® Fire-Resistant Roof Deck Protection Chapter 15 of the IBC or Chapter 9 of the IRC, a self can also be used over existing wood shakes or shingles as adhesive polymer bitumen sheet, complying with ASTM an alternative to the covering materials specified in Section D1970 or the ICC ES Acceptance Criteria for Self adhered 1510.4 of the IBC or Section R907.4 of the IRC. Underlayments for Use as Ice Barriers (AC48), is to be applied. The underlayment is to be applied over the solid VersaShield® Fire-Resistant Roof Deck Protection is also substrate in sufficient courses so that the underlayment used as a component of classified roofing assemblies as extends up the roof a distance equal to the distance inside described in Section 4.3, when installed in accordance with the exterior wall line of the building that is specified by the this report. applicable code. The underlayment, applied in the field of ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed,nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use.There is no warranty by ICC Evaluation Service,LLC,express or implied,as Hat cm) to any finding or other matter in this report,or as to any product covered by the report. Wran Copyright©2017 ICC Evaluation Service,LLC.All rights reserved. Page 1 of 4 ESR-2053 I Most Widely Accepted and Trusted Page 2 of 4 the roof, is to completely overlap the ice barrier (severe IRC; or any roofing assembly having a Class A, B or C roof climate underlayment) protection a minimum of 2 inches classification, without reducing the roof classification. (51 mm). When installed in accordance with Section 4.1 and Table 1 of this report, roofing assemblies incorporating Installation of the roof covering can proceed immediately VersaShield® Fire-Resistant Roof Deck Protection have following the underlayment application. The underlayment the roof classification specified in Table 1. The roof is to be covered by a roof covering within the time set forth coverings must be recognized in a current ICC-ES in the manufacturer's published installation instructions. evaluation report as shown in Table 2. 4.2 Reroofing: 5.0 CONDITIONS OF USE The existing roof must be inspected in accordance with The VersaShield® Fire-Resistant Roof Deck Protection Section 1510 of the IBC or Section R907 of the IRC. The new roof covering is installed over the VersaShield® described in this report, complies with, or is a suitable Fire-Resistant Roof Deck Protection in accordance with the alternative to what is specified in, those codes listed in roof covering manufacturer's published installation Section 1.0 of this report, subject to the following instructions. The new roof covering must be recognized in conditions: a current ICC-ES evaluation report, and, when applicable, 5.1 Installation must comply with this report; the the evaluation report must address installation over wood manufacturer's published installation instructions and shake,wood shingle or asphalt shingle roofs. the applicable code. In the event of a conflict between 4.2.1 Existing Wood Shakes or Shingles: Where the the manufacturer's published installation instructions application of a new roof covering over wood shingle or and this report,this report governs. shake roofs creates a combustible concealed space, 5.2 Installation is limited to roofs with a minimum slope of VersaShield® Fire-Resistant Roof Deck Protection can be 2:12 (16.67 percent slope) or to the minimum slope used as an alternative to the covering materials specified required for the roof covering in accordance with the in Section 1510.4 of the IBC or Section R907.4 of the IRC. applicable code,whichever is greater. The underlayment covers the entire existing wood roof. 5.3 Installation is limited to use with roof coverings that do Battens used for the new roof covering system are not involve hot asphalt or coal tar pitch. installed over the underlayment. The underlayment may be placed under or over counterbattens, spaced a maximum 5.4 Installation is limited to use with approved roof of 24 inches (610 mm) on center. The underlayment is coverings that are mechanically fastened through the fastened to the counterbattens with a sufficient number of underlayment to the sheathing or rafters. nails, having tin caps or 1-inch-diameter (25.4 mm) plastic 5.5 Installation is limited to roofs with ventilated attic caps, to hold the underlayment in place until the spaces in accordance with the requirements of the horizontal battens and roof covering are applied. When applicable code. counterbattens are installed over the underlayment or when counterbattens are not used, the underlayment is 5.6 VersaShield® Fire-Resistant Roof Deck Protection is fastened directly to the existing roof covering in the same produced in Conover, North Carolina, under a quality manner. control program with inspections by ICC-ES. 4.2.2 Existing Asphalt Shingles: When installed over 6.0 EVIDENCE SUBMITTED existing asphalt shingles, the underlayment is applied over Data in accordance with the ICC-ES Acceptance Criteria the existing roof covering and fastened through the for Nonasphaltic Fiberglass-based Roof Underlayment shingles to the sheathing with a sufficient number of nails, (AC160), dated January 2000 (editorially revised February having tin caps or 1-inch-diameter (25.4 mm) plastic caps, 2014). to hold the underlayment in place until the roof covering is applied. 7.0 IDENTIFICATION 4.3 Roof Classification: Each roll of underlayment bears a label indicating the GAF When installed in accordance with this report, name and address, the plant identification, the product name, the roll number, and the evaluation report number VersaShield® Fire-Resistant Roof Deck Protection can be used as an alternative to Exception 2 to Section 1505.2 of (ESR-2053). the 2012 and 2009 IBC, the Exception to Sections 1505.2 and 1505.3 of the 2006 IBC, and Section R902.1 of the ESR-2053 I Most Widely Accepted and Trusted Page 3 of 4 TABLE 1—ROOF CLASSIFICATION OF ASSEMBLIES INCORPORATING VERSASHIELD®FIRE-RESISTANT ROOF DECK PROTECTION ROOF COVERING2 SUBSTRATE UNDERLAYMENT' ROOF MAXIMUM CLASSIFICATION SLOPE Class A asphalt glass fiber shingle 15/32-inch plywood One layer VersaShield® A Unlimited Stone coated,steel,direct to deck, 15,32 inch plywood or 0.013-inch thickness(0.330 mm), spaced sheathing One layer VersaShield® A Unlimited shingles or panels 15 One layer VersaShield®,and /32 inch plywood or one layer Type 30 asphalt A Unlimited Steel direct to deck,0.013-inch spaced sheathing thickness(0.330 mm),shingles or saturated organic felt panels 15/32 inch plywood or One layer VersaShield® B Unlimited spaced sheathing 15/32-inch plywood or One layer VersaShield® A Unlimited spaced sheathing Steel over battens,0.013-inch Existing wood shakes or thickness(0.330 mm),shingles or shingles installed over Two layers VersaShield® A Unlimited panels spaced or solid sheathing Existing wood shakes or shingles installed over One layer VersaShield® B Unlimited spaced or solid sheathing Steel,0.016-inch thickness(0.406 15/32 inch plywood or mm),panels or standing seam spaced sheathing One layer VersaShield® A Unlimited system 15/32 inch plywood or One layer VersaShield®,and spaced sheathing one layer Type 30 asphalt A Unlimited saturated organic felt Existing wood shakes or shingles installed over Two layers of VersaShield® A Unlimited Copper,0.016-inch thickness(0.406 spaced or solid sheathing mm),shingles or panels 15/32-inch plywood or spaced sheathing One layer VersaShield® B Unlimited Existing wood shakes or shingles installed over One layer of VersaShield® B Unlimited spaced or solid sheathing 15/32 inch plywood or Two layers VersaShield® A Unlimited spaced sheathing Aluminum,0.018-inch(0.457 mm), 15/32-inch plywood or One layer VersaShield® B Unlimited shingles,panels,or standing seam spaced sheathing system Existing wood shakes or shingles installed over One layer VersaShield® B Unlimited spaced or solid sheathing 15/32-inch plywood Two layers VersaShield® A 11/2:12 TPO,CSM,CPA,EPDM,cap sheet, 15,32 inch plywood, ® 1 or modified bitumen single-ply insulation Two layers VersaShield® A 1 /2:12 membranes 15/32-inch plywood One layer VersaShield® B 11/2:12 15/32-inch plywood Two layers VersaShield® A 2:12 PVC single-ply membrane 15/32 inch plywood, Two layers VersaShield® A 11/2:12 insulation 15/32-inch plywood One layer VersaShield® B 11/2:12 For SI: 1 inch=25.4 mm. 'Underlayment must be installed in accordance with Section 4.0 of this report. 2Roof coverings must be recognized in a current ICC-ES evaluation report.The roof covering must comply with the Class A or B flame-spread requirements of UL790(ASTM E108),as applicable to the systems defined in this table. ESR-2053 I Most Widely Accepted and Trusted Page 4 of 4 TABLE 2—EVALUATION REPORT CROSS-REFERENCE COMPANY ICC-ES EVALUATION RECOGNIZED PRODUCT REPORT NUMBER Allmet Roofing Products Ltd., dba Allmet Roofing Continental,Wood Shakes,Shadowline, Talavera SF,Classic Products ESR-1286 Tile 1,Talavera NB,Tudor Slate NB, Ridgewood NB and Classic Tile NB Carlisle Syntec ESR-1463 EPDM, PVCand TPO Single-Ply Membranes Delta Building Products,Ltd. ESR-1790 Aluminum and Steel Roofing Shingles and Panels Decra Villa Tile, Decra Shake XDTM and Decra Shingle XDTM Decra Roofing Systems,Inc. ESR-1754 Steel Roofing Panels Decra Roofing Systems,Inc. ESR-1483 Decra Shingle Steel Roofing Panels Decra Roofing Systems, Inc. ESR-2901 Steel Roofing Panels: Decra Tile,Decra Shake,Decra Shingle Plus Gerard,Allmet,Storm Loc, Energy Loc,Armor,Eco Loc, Rof Gerard Roofing Technologies ESR-1188 Loc,Storm Loc,and Stormtile Brands of Guardian,Granite Ridge, Diplomat and Diplomat Plus Steel Roofing Panels Steel Roofing Panels:Tile;Shake;Canyon Shake;Barrel Gerard Roofing Technologies ESR-1491 Vault; NB Tile in the following brands:Allmet,Armor,Eco Loc, Energy Loc,Gerard, Roof Loc,Stone Loc,Storm Loc, Stormtile Firestone Building Products Company, LLC ESR-2831 Firestone UltraPlyTm TPO and TPO XR Singly Ply Roofing Membranes Ideal Roofing Company Ltd. ESR-3101 Wakefield Bridge(26 gage)Steel Panels and Wakefield Bridge(29 gage)Steel Panels Ideal Roofing Company Ltd. ESR-3100 HF-16 and HF-20.25 Roof Panels DaVinci Roofscapes,LLC ESR-2119 DaVinci Slate,DaVinci Shake,Bellaforte Shake and Bellaforte Slate Roof Shingles Feroof Co.,Ltd. ESR-3331 Steel Roofing Panels:Veneto I, Veneto II,Rio, Rio EZ,Diva,Wood,Zissen and Slate Ensoltis Green Hybrid Roofing LLC ESR-2904 Ensoltis Savanna S Roof Tile Custom-Bilt Metals ESR-2048 Custom-Bilt Standing Seam Metal Roof:CB-150 and SL-1750 2001 Company,Inc.,dba Kelly Company-2001 Inc. ESR-3185 2001 Company Inc.EPDM,PVC and TPO Single Ply Roofing Membranes Roser Co.,Ltd ESR-1763 Roser Steel Roofing Panels:Spany, Roser Bond,Rowood, Tuscany Tile and Stonewood Shake Berridge Manufacturing Company ESR-3486 Berridge Cee-Lock and Zee-Lock Standing Seam Roof Panels 'The aluminum panels are limited to Class B roof covering assemblies.