Loading...
HomeMy WebLinkAboutFile Documents.1112 Waters Ave.0089.2017 (14).ARBK QG� SEALANT WITH LL.OW E COA PANE SKYLIGHT WIDTH S G��� SEE DETAIL �\ 15 ga. ROLL-FORMED 1�' \ ALUMINUM FRAME _ _ WITH KYNAR500 \ FINISH 111411111 Pill r // STAINLESS , tit sc."REv so On , F. THERMAL BREAK 7,/! GASKET WITH 1 INTEGRAL � ��� � CONDINSATION GU IERAND WEEP HO SATE �� 3/g WEEP HO T FS > r1 :: NT YM AT CORNERS __ ��� OTHERS /:!%%�/: v NO0AX'C L //�.� j/ii �� � 0 FLASHING - - - - - - - / SHINGLE DRYWALL BYOTHERS BY OTHERS FRAME APERTURE WIDTH �GIA (INSIDE CURB) � GItBI - FRAME WIDTH JJ �O T�dC3� (OUTSIDE CURB) '0RO A THROAT WIDTH ///// DECKING VERTICAL CRO SS SECTION HORIZONTAL CRO SS SECTION BYOTHERs 1-1/2"WOODCURB 2"x4"MINIMUM BY OTHERS PRO DUCT DIMEN SIO N S DETAIL 4111 METRIC UNITS (MUMMERS)RS) IMPERIAL UNI'IS (INCHES) FRAME FRAME SKYLIGHT THROAT FRAME FRAME SKYLIGHT THROAT DAYLIGHT FRAME FRAME SKYLIGHT THROAT FRAME FRAME SKYLIGHT THROAT DAYLIGHT SKYLIGHT CO DE CERTIFICATIO N S: SIZE WIDTH APERTURE WIDTH WIDTH HEIGHT APERTURE HEIGHT HEIGHT AREA* SIZE WIDTH APERTURE WIDTH WIDTH HEIGHT APERTURE HEIGHT HEIGHT AREA* WIDTH HEIGHT (SQ.M) WIDTH HEIGHT (SQ.FT.) *National Evaluation Service Report: NER 550 2222 648 572 679 667 648 572 679 667 0.33 2222 25 1/2 22 1/2 26 3/4 26 1/4 25 1/2 22 1/2 26 3/4 26 1/4 3.52 *WIMA Hallmark#426 2234 648 572 679 667 953 876 984 971 0.50 2234 25 1/2 22 1/2 26 3/4 26 1/4 37 1/2 34 1/2 38 3/4 38 1/4 5.39 2246 648 572 679 667 1257 1181 1289 1276 0.68 2246 25 1/2 22 1/2 26 3/4 26 1/4 49 1/2 46 1/2 50 3/4 50 1/4 7.27 *NFRC Certified &Labeled 3030 851 775 883 870 851 775 883 870 0.60 3030 33 1/2 30 1/2 34 3/4 34 1/4 33 1/2 30 1/2 34 3/4 34 1/4 6.46 3046 851 775 883 870 851 1181 1289 1276 0.92 3046 33 1/2 30 1/2 34 3/4 34 1/4 49 1/2 46 1/2 50 3/4 50 1/4 9.85 * Tested to comply with intent of OSHA Fall Prevention 3434 952 876 984 971 952 876 984 971 0.77 3434 37 1/2 34 1/2 38 3/4 38 1/4 37 1/2 34 1/2 38 3/4 38 1/4 8.27 regulations. (No breakage up to 400 lbs. for 4622 1257 1181 1289 1276 1257 572 679 667 0.68 4622 49 1/2 46 1/2 50 3/4 50 1/4 25 1/2 22 1/2 26 3/4 26 1/4 7.27 4646 1257 1181 1289 1276 1257 1181 1289 1276 1.39 4646 49 1/2 46 1/2 50 3/4 50 1/4 49 1/2 46 1/2 50 3/4 50 1/4 15.02 ComfortPlus glass) PRO DUCT DATA Typical FCM Skylight Applications SKYLIGHT GLAZING THERMAL VALUES STRUCTURAL PRESSURES DOWNIAAD(SNOWLOAD) Light Shaft with Asphalt Shingles CODE DESCRIPTION EXIERIORPANE AIRSPACE INTERIOR PANE U-factor SHGC Vt Minimum Maximum WINDUPLIFF(DP) 0075 ComfortGlass 1/8"Tempered 7/16" 1/8"Tempered 0.40 0.34 0.52 Not Applicable Not Applicable Cathedral Ceiling with Asphalt Shingles 0074 ComfortPlus 1/8"Tempered 7/16" Two 3/32"Heat-Strengthened with 0.030"Interlayer 0.40 0.34 0.53 35 psf 55 psf 80 psf 0099 10 Snowload 1/8"Tempered 7/16" Two 1/8"Tempered Laminated with 0.030"Interlayer 0.40 0.34 0.53 96 psf 182 psf Not Applicable 0099 23 White laminated 1/8"Tempered 7/16" Two 3/32"Heat-Strengthened with 0.030"White Interlayer 0.40 0.31 0.38 35 psf 55 psf 80 psf VELUX Name Date 0099 69 Impact Glass 1/8"Tempered 7/16" Two 3/32"Heat-Strengthened with 0.090"Interlayer 0.40 0.34 0.53 Not Applicable +47 psf/-47 psf V E LUX 1418 Evans Pond Road Greenwood,SC 29649 Drawn by JDH Jan.03 Cheeke 1.GIAZINGS0075&0074 ARE THE ONLY FCM GLAZING S THAT ARE NFRC CERTIFIED&LABEED. 1-800-88- SAUX �ini E1VE 1) Sky-Product Management www.VECUXUSA com Drawing 2.THERMAL VALUES FOR0099 10,0099 23&0099 69 ARE SIMULAtED USING NFRC PROCEDURES. 3.MINIMUM SNO WLO AD VALUES ARE OBTAINED FROM THE FCM 4646 SIZES.AU.SNO WLO AD VALUES ARE GIVEN WITH SAFETY FACTOR OF 3. FCM- Fixed Curb Mounted Skylight 4.MAXIMUM SNOWLOAD VALUES ARE OBTAINED FROM THE FCM 2222 SIZES.AIL SNOWLOAD VALUES ARE GIVEN WITH SAFEIYFACTOROF 3. Product Data, Product Dimensions, Code - 12/0 7/1 Certifications, Cross Sections &Enlarged Detail This drawing is an instrument of service and is provided for informational use only. ASPEN BUILDING DEPARTMENT