HomeMy WebLinkAboutFile Documents.1112 Waters Ave.0089.2017 (23).ARBK Tim Andrulaitis From: Eric Celko <ericcelko@dynamicwindows.com> Sent: Thursday, April 06, 2017 11:10 AM To: Tim Andrulaitis Subject: RE: new project - 1112 waters ave, aspen Tim: "U"values for our windows/doors as follows: Direct glazed (no sash) fixed windows: .24"U" value Casement/awning windows: .30 "U" value In-swing hinged doors: .28 "U"value Out-swing hinged doors: .27 "U"value Lift& slide doors: .27 "U" value In order to achieve the above NFRC tested "U" values the glazing must be dual glazed using Cardinal 272 on the exterior pane and Cardinal i89 glass on the room side pane with high altitude argon gas and a warm edge perimeter spacer bar. The i89 glass is only available up to sizes of 78" x 144"or 84" x 137" so keep this in mind when designing your larger picture windows or lift &slide doors. If the above glass size restrictions are an issue, we can provide triple glazing which would achieve similar"U"values and work within 96" x 137" or 84" x 144"glass sizes.The triple glazing obviously adds some weight to the operable windows/doors and extra costs so I tend to promote the dual glazing unless the above glass sizes pose too big of a design restriction. Let me know if this answers your question. On a side note, I've booked a trip to Aspen for the week of April 24-28th. I would like the opportunity to stop by your office while I'm in town to show you more updated samples and discuss current/future work. Let me know if you'll be in town that week and I'll call you to schedule an appointment with you and your associates. All the best, Eric Received 5/15/17