HomeMy WebLinkAboutFile Documents.1112 Waters Ave.0089.2017 (25).ARBK Markup Summary P Permit set 05.05. 17 6-5-2017 P Permit set 05.05.17.pdf(30) Page Label: C-003 Author: mikeh Micropile wall is proposed Date: 6/5/2017 10:54:03 AM directly within existing tree. M;eroniewall s props directly within Please adjust plans.to account \ existing tree Pleaseadjustpl File Name: P Permit set 05.05.17.pdf count for excavationstabilization. for excavation stabilization. REMOVE 1 CIVIL - This tree does not exist on the survey. RE: C-002 for current �LAosToNE WALKWAY ESTO 7 \ 4` RELOCATE EXIST survey with all existing trees. \ \ \ EL EC AND TELEPHONE 7CV _ Page Label: C-101 —'9'z Author: mikeh Please include detail for drain Date: 6/5/2017 3:16:42 PM penetration of wall as well as File Name: P Permit set 05.05.17.pdf rock bed with depth and type of rock. 972 2 CIVIL - This drain no longer exists due to the 10' setback requirement • Please include detail for drain from Wheeler Ditch center line where no development is allowed. penetration of wall as well as rock bed • with depth and type of rock. ROOF ORATN TIE IN-A! Page Label: C-102 , "' T Storm pipe is route directly on p PTPE-A,TN"IN: �, Author: mikeh —PIPE-A3 Date: 6/5/2017 2:10:07 PM top of micropile wall. Please not J,`gIPEJOLNT File Name: P Permit set 05.05.17.pdf how installation of pipe will occur DFF a °' at all conflicts. � , m� Gp route pl II Please not how �`��t",`r r pipe wll occur atall 3 CIVIL - The storm system has been routed closer to the building to �� PIPE-AI STORM SYSTEM run further away from the proposed micropile wall location. PROPOSED SURFACE '.'A A PIP;JOINT-, m Page Label: C-102 �` .� Building envelop must be ��// Author: mikeh / � // E Date: 6/5/2017 11:42:56 AM depicted on all relevant sheets. �� 7 Please adjust plans. I %Y �� ��a� - File Name: P Permit set 05.05.17.pdf - 4 CIVIL + LANDSCAPE - Building envelope has been added to sheets C-101, C-102, C-103, L103 and L104. Iwil. Page Label: C-102 Author: mikeh/y Pipe appears to run directly Date: 6/5/2017 2:06:48 PM through the drip line of an • "' File Name: P Permit set 05.05.17.pdf existing tree. No excavation is • "=°PI he allowed within drip lines. Please °° re-route storm pipe. 5 CIVIL - This tree does not exist on the survey, RE: C-002 for current survey with all existing trees. Sheet C-102 has been changed to \,:::::"-- reflect current survey. RECEIVED 12/07/17 ASPEN BUILDING DEPARTMENT Page Label: C-102 -aZi " Author: mikeh Planting trees over storm lines is '` Date: 6/5/2017 3:29:19 PM not recommended. Future "`E At =„„„=r=— °F File Name: P Permit set 05.05.17.pdf maintenance becomes very 3 difficult and expensive. =m` �"�ce 6 CIVIL/LANDSCAPE -The trees in question have been shifted slightly away from ,a„r„ ,�omn�ry .�.�,�. [r�, .4®a 8 R „� t the proposed storm drain. It is understood by the homeowner and design engineer that it is not recommended to plant trees over storm lines, however, it is not a concern with proposed Aspen trees. ' Page Label: C-102 Author: mikeh No ROW drainage conveyance Date: 6/5/2017 3:18:40 PM design is supplied. Please ..—" / File Name: P Permit set 05.05.17.pdf incorporate a ROW conveyance :„��,�,:,,, '-'"i / system to design and ensure proper capacity. R ,, ms / 7 CIVIL- For ROW drainage, the gravel shoulder/parking area is to be used for e. detention. A calculation for this detention has been added to sheet C-101, requiring Eo,ao.o ° 1' of gravel for the shoulder. Callouts on sheets C-102 and C-103 have been F.sz modified to reflect this ROW detention system. Page Label: C-102 I- Author: mikeh per,: Please note location of ACO ; Date: 6/5/2017 2:33:23 PM K100 Brikslot. Slot drain location / File Name: P Permit set 05.05.17.pdf and extents are unclear. . 8 CIVIL - Callouts have been added to sheet C-102 to depict the / extents of the slot drain for this walkway at the front of the residence. o Page Label: C 102 Grading steeper than 3:1 - Author: mikeh requires permanent stabilization. 4 Date: 6/5/2017 2:04:01 PM " ® File Name: P Permit set 05.05.17.pdf Please adjust plans to include stabilization or re-design to Grad ng steeperth 3:1 q°fires pnsantadert C oee °at include nothing steeper than 3:1. plans too include stabilization or re-design °°'ude°othngateeperthan3l 9 CIVIL - Grading in this area has been modified after all development Z 6.STEPS within 10' offset from Wheeler Ditch center line has been removed. 1 6SIFPS There is no grading within the 10' offset of the Wheeler Ditch on the property. P"""P""""` ° Wx Page Label: C-103 Please provide turf stone porous Author: mikeh S55.5513 x paving detail and verify it is Date: 6/5/2017 2:20:44 PM TUFFS TONE traffic rated. P°"°°--''''< File Name: P Permit set 05.05.17.pdf a'oa'P peaseprovidela stnne�r°°spa° 10 CIVIL - The turfstone pavement driveway section has been replaced detail and ed�t.a tram°atad. x_' with a gravel surface to match the existing material on the property. o'"oRNEw^.ALIGN. No detail for turfstone pavement is required. 1o. RECEIVED 12/07/17 ASPEN BUILDING DEPARTMENT Page Label: C-103 °""',4z \ �e No construction is allowed within Author: mikeh \.°E Date: 6/5/2017 2:23:36 PM 10'of centerline of the ditch. �I` File Name: P Permit set 05.05.17.pdf Please adjust plans. 11 CIVIL - All development on this project within 10' of the ditch center 40 line has been removed. Pa construct on is allowed within,Paasa� Plans , iv Page Label: C-103 A A ;, 7 •-: Author: mikeh Please note material of walk way rs " m '''-' Date: 6/5/2017 2:28:46 PM p on lans. ,,, „, . ,ate ' File Name: P Permit set 05.05.17.pdf 1�' 4*sr ° 12 CIVIL - Walkway materials are now called out on sheet C-103. -...... ......( ,r Page Label: C-103 Author: mikeh Please include snowmelt PERMEABLE DRIVEWAY WIT Date: 6/5/2017 2:19:11 PM permeable driveway detail (only SNOWMEL T UP TO PROPERTY LLN File Name: P Permit set 05.05.17.pdf a patio detail is included). P'ea5e1°°'°des°°wme°pe�ea°�� 13 CIVIL - The pervious snowmelted pavement section of the driveway driveway tletail(only a patio tletail is included). has been replaced with impervious snowmelted pavement. This detail is provided on sheet C-501. All driveway runoff is collected and conveyed through a trench drain located at the property line. k Page Label: C-104 \\ ' Author: mikeh The water service line is longer Date: 6/5/2017 3:32:30 PM than necessary and should be shortened as much as possible. x File Name: P Permit set 05.05.17.pdf Please adjust plans. >:E 14 CIVIL - The water service line has been tied into the house at the `°_-_-:t-:' ,'/'. garage rather than routed around the residence. - r Page Label: C-104 Author: mikeh Please confirm capacity of existing electrical infrastructure. Date: 6/5/2017 11:29:05 AM If an upgrade is required,then o°°, " n File Name: P Permit set 05.05.17.pdf °"°°"`°" \ property must relocate mom\ 15 The existing transformer servicing the infrastructure onto private requ red then property must P'� �°°,,,°"E,E°.A,C residence is a 100 KVA transformer. It property and include an easement with required will net be required to be upgraded per clearances. Holy Cross Energy. A callout to page C-104 has been added to describe the size of the existing electrical transformer. RECEIVED 12/07/17 ASPEN BUILDING DEPARTMENT /, Page Label: C-104 MB,Bo Author: mikeh Proposed tap location is located "EPE„�,Fo,"w,,Ea Date: 6/5/2017 3:32:39 PM at bend in the water main.All aEPT FaAT,P / File Name: P Permit set 05.05.17.pdf taps must occur 18"from fittings. Please adjust tap location. ProPo=aa� „o,,,oa,aaa,tiea 16 CIVIL - The water service line tap has been shifted 18" from the bend the mter ma n All must occur OCABLE in the pipe. The callout has been modified to install tap 18" from any ,�o - fittings. ,, _/c/,,a\ \\. y EAr Page Label: C-104 Utilities cannot be within 10'of ..% Author: mikeh centerline of ditch. Please adjust Date: 6/5/2017 3:13:31 PM p ,� ,,„„„ , \ File Name: P Permit set 05.05.17.pdf lans. 17 CIVIL - Utilities have been rerouted to avoid Wheeler Ditch setback � requirements. Page Label: C-104 Author: mikeh Fire flow calculations must be OLE 1'TYPE R provide to verify the necessity of LINE PER COA STAh Date: 6/5/2017 11:36:03 AM CONTACT C°A a 2"service line. Please provide °EPT.R File Name: P Permit set 05.05.17.pdf Fire°wcalculatl°°sm°tbepr°vide[° / fire flow calcs that prove the line °eriYthe°e°eaa"Yofa2"aerv'celipe 18 Letter provided by Flame Out Fire size smaller fails as well as the Please provide fire flow talcs that prove - nenealzeamaller ailaaawellaa he / proposed size works. proposedai=ewora Protection stating requirements of the proposed system. SEE "E18. Flame Out Letter". Page Label: C-104 Author: mikeh Please note to abandon existing Date: 6/5/2017 11:24:39 AM On,LIS SERVICE water service line per COA === ' / File Name: P Permit set 05.05.17.pdf standards. " °`°"`°" °" 19 CIVIL - This has been addressed and noted on C-003. /P , /x x x x x Page Label: C-104 Author: mikeh Crossing design must be included in plans. 18"of Date: 6/5/2017 11:32:22 AM File Name: P Permit set 05.05.17.pdf separation is required. Please ��s, dn';m�=,„e,��,�aea; adjust plans to include crossing �cieesa a w%,pima w ma°ae u�ma design/detail. aame�rae,�n. a 20 CIVIL - Detail for the water/sewer crossing has been added to \ \s , ,, C-502. This detail includes the requirement of 18" vertical separation between the water and sewer lines per COA standards. RECEIVED 12/07/17 ASPEN BUILDING DEPARTMENT :°-\ Page Label: C-104 How would excavation for water Nx Author: mikeh Date: 6/5/2017 3:14:37 PM service line occur without r,E.E^r„ �'\\A File Name: P Permit set 05.05.17.pdf effecting the ditch? It is beyond limits of the micropile wall. \ \ ' ''' Please verify all utilities are �a o..,tia constructible. "'m°°°�°m'°�°� '\\� 21 CIVIL - The water service line has been rerouted to tie into the P �,r.e residence at the garage. There is no issue installing the water service line without affecting the ditch. Page Label: C-501 Author: mikeh Please include Figure 8.32 in Date: 6/5/2017 3:11:06 PM plans. Contractor will not have URMP on site, and detail must Please include Figure 8.32 in p File Name: P Permit set 05.05.17.pdf Contractor will not have URMP on be in plans. and detail must be in plans. 22 CIVIL - The perforated pipe and detail have been removed from FREFER I OR ATI plans due to the 10' Wheeler Ditch setback requirements. There THE STR is no need to add this detail from the URMP to the plans. sI- Page Label: GRADE-2 Micropile wall runs directly 0 I Author: mikeh Date: 6/5/2017 10:53:16 AM through existing tree that is Micropilewell runsdirectly through File Name: P Permit set 05.05.17.pdf proposed to remain. Excavation existing tree that is proposed to remain can not occur within drip lines of Excavation can not occur within drip Imes of existing traea.Please ad;nst existing trees. Please adjust plans. plans. � �`\ ,o, �� II 23 This tree to remain does not exist. SEE current survey. d /' Page Label: GRADE-2 �l Deep utilities need to be Author: mikeh 11-* depicted on plans to ensure no �c � Date: 6/5/2017 10:43:11 AM p File Name: P Permit set 05.05.17.pdf conflicts exist. Please adjust plans to include all utilities. Deep utilities need io ba depicted on plans to ensure no conflicts exist.Please \..,\ a\;pstplana reallntilitiea 24 Utilities are depicted on plans. / Miaopile Wall / y 'f N Page Label: GRADE-2 Please include limits of -SMUGGLER VIEW 1 2 Author: mikeh excavation in this area to ensure Date: 6/5/2017 10:55:21 AM `r[�� Please include limits of excavation inthls File Name: P Permit set 05.05.17.pdf no conflicts exist. Q� �:(�R area to enure no conflicts exist. / 25 Limits of disturbance depicted on plans Minaplie Wall / // Sterl Well RECEIVED 12/07/17 ASPEN BUILDING DEPARTMENT Page Label: GRADE-2 Author: mikeh How will excavation occur for Date: 6/5/2017 11:26:32 AM drywell? Please include File Name: P Permit set 05.05.17.pdf stabilization plan for drywell l N. . 1 1 excavation. How will excavation occur for drywell? I NPlease include stabilization plan for �drywellcafion. 26 CIVIL - Excavation layback limits for the drywell have been added 11 II i to C-003, per OSHA standards in Type B soils. A note has also I been included on C-003 for excavations near the driplines of / . \ I ` adjacent trees. / A�� Page Label: L104 Large landscaping is not allowed , Author: mikeh. within utility easements. Trees \ Date: 6/5/2017 2:52:15 PM cannot be planted on top of s\ File Name: P Permit set 05.05.17.pdf existing utilities. Please adjust plans. tleap9r °raowdwr"i gea,ae=PIJ 27 LANDSCAPE - Plantings amended, SEE: L104. atl,ust plansQuaking Aspen ` 4'CAL B68(]) Cuaking Aspens \ C"CAL BSB(9) '\-— - -' 4 -"" Page Label: Z103 Author: mikeh Does utility/trail have easement. \ Please include trail easement � ` ,,,ten. ,�'� Date: 6/5/2017 10:37:05 AM ll `\ r File Name: P Permit set 05.05.17.pdf information if easement exists .,r " 28 SEE "Z1.0 198_556" and "Z1.1 205-136" for easement information. w,...�`'�.o a7.7 ro. /� z Page Label: Z103 >, � Does ditch have an easement -,,,, *,, Author: mikeh through property? Please - -, .. Op- Date: 6/5/2017 10:30:17 AM include ditch easement Pa File Name: P Permit set 05.05.17.pdf /� information if easement exists. ,. 29 SEE "Z1.0 198_556" and "Z1.1 205-136" for easement B` °eesd°`""a°eaneaeme°""mpg" information. property?Please inclutle ditch easement -\ information if easement exists. Page Label: Z103 Author: mikeh Deep utility lines must be oaapatilltylinesma bedepicfed°n / Date: 6/5/2017 10:29:14 AM depicted on the survey. Please be saney Pleaee lndade all afilitleson / include all utilities on the survey. esu ey File Name: P Permit set 05.05.17.pdf / \ 30 SEE: Z103. / RECEIVED 12/07/17 ASPEN BUILDING DEPARTMENT