HomeMy WebLinkAboutFile Documents.121 S Galena St.0083.2018 (8).ACBK Halo Commercial
DESCRIPTION
Catalog# Type
Recessed 6-inch LED lens downlight is available in various
distributions,lumen and CRI/CCT options.Suitable for commercial Project
construction and can be used for both new or renovation work.
Insulation must be kept 3"from top and sides of housing. Use for Comments Date
general area lighting where high efficiency and visual comfort are
required.
Prepared by
SPECIFICATION FEATURES
MECHANICAL Reflector i' """"
Frame One piece parabolic aluminum - ,
Boat shaped galvanized steel reflector provides cutoff for Compliance \
frame with adjustable plaster a visually comfortable optic. -
cULus listed for wet location � ��`�
lip accommodates ceilings up Attaches to LED module with (3) cCSAus listed for wet location
to 1/2-2"thick. May be used for speed clamps minimizing light -IP66 Ingress Protection Rated
new construction or remodeling leaks to lens.Self-flanged standard -Insulation must be kept 3"from
installations. Provided with (2) with an optional white painted top and sides.
remodel clips to secure frame flange. -Airtight per ASTM-E283.
when installed from below the Trim Retention -Optional City of Chicago PD610
ceiling. Reflectors are retained with two environmental air(CCEA)
Mounting Brackets torsion springs holding the flange marking for plenum applications. PD615
Bar hanger receivers adjusts 2" tightly to the finished ceiling -EMI/RFI emissions per FCC 47CFR PD620
vertically from above the ceiling surface. Part 18 non-consumer limits.
or thru the aperture. Use with ELECTRICAL -Contains no mercury or lead and PD630
No Fuss TM bar hangers or with Junction Box RoHS compliant.
1/2" EMT. Removable to facilitate (6)1/2"and(2)3/4"trade size pry -Photometric testing in
installation from below the ceiling. outs positioned to allow straight accordance with IES LM-79-08. PDM6A
No FUSSTM Bar Hangers conduit runs. Listed for(12) -Lumen maintenance projections
Captive preinstalled bar hanger #12 AWG(six in,six out)90°C in accordance with IES LM-80-08
locks to tee grid with a screwdriver conductors and feed thru branch andTM-21-11. 61 V
or pliers.Centering mechanism wiring. -Can be used to comply with
allows consistent positioning of Driver CaliforniaTitle 24 Non-Residential
fixtures. Integral UNV 120-277V 50/60 Hz Lighting Controls requirements 1000, 1500,
OPTICAL constant current driver provides as a LED Luminaire. 2000 & 3000
LED Module noise free operation. For 347V -ENERGY STAR®listed for
Proximity phosphors over chip input use Halo transformer H347 Lumen Series
commercial applications,
on board LEDs provide a uniform or H347200. Continuous,flicker- reference database for current
source with high efficiency and no free dimming from 100%to 10% listings.
pixilation.Available in 80 or 90 CRI with leading or trailing edge LED
minimum,accuracy within phase cut at 120V or 0-10V analog 6-Inch Aperture
3 SDCM provides color uniformity. control.
See ordering information for Lens Downlight
Emergency Option
available CRI/CCT options. Provides 90 minutes of standby
Passive thermal management lighting meeting most life safety
achieves L70 at 50,000 hours codes for egress lighting.Available
in non IC applications. Integral with both integral or remote
diffuse lens provides visual charge indicator and test switch.
shielding. Integral connector
allows quick connection to
housing flex. THD:<20%
PF:>_0.90
T Ambient-30-+40°C
Sound Rating<22dba
Lumens 1000 Series Lumens 1500 Series Lumens 2000 Series Lumens 3000 Series
Input Voltage 120V 277V Input Voltage 120V 277V Input Voltage 120V 277V Input Voltage 120V 277V
Input Current .103 A .058 A Input Current .146 A .1 A Input Current .175 A .536 A Input Current .299 A .145 A
Input Power 12.1 W 13.2 W Input Power 17.1 W 17.9 W Input Power 20.78 W 21.06 W Input Power 35.72 W 36.4 W
Efficiency 88 LPW 88 LPW Efficiency 87 LPW 87 LPW Efficiency 89 LPW 89 LPW Efficiency 82 LPW 82 LPW
Inrush Current .048 A .080 A Inrush Current 1.920 A 0.960 A Inrush Current .064 A .128 A Inrush Current .096 A .928 A
-WINED
08/16/2018
E_T•IV AS003EN
Powering Business Worldwide /28/2015