HomeMy WebLinkAboutFile Documents.1008 E Hopkins Ave.0106.2017 (14).ARBK 2015 IECC RESIDENTIAL RENEWABLE ENERGY MITIGATION PROGRAM
City of Aspen Version 11.1 Updated March 28 2017
PROJECT ADDRESS: 1008 E. Hopkins Ave.
Parcel ID#: 2737 18 125 001 Permit Number:
CONTACT INFORMATION :
Owner:
Name: Arthur Bellis City: Aspen
Address: 1008 E.Hopkins Ave. State: CO
Email: Zip Code: 81611
Phone: Cell Phone:
Owner's Representative:
Name: Rybak Architecture&Development,P.C. City: Aspen
Address: 600 E.Hopkins Ave.,Suite 303 State: CO
Email: dave@daverybak.com Zip Code: 81611
Phone: 925 1125 Cell Phone:
A. RESIDENTIAL RENEWABLE ENERGY MITIGATION PROGRAM
Sheets showing snowmelt, pool, spa, and solar/GSHP information: A2.0
Do you have snowmelt or a spa that has been exempted by the buiding official? ()Yes(enter sqft below on the exempt row) QQ No
Hydro Snowmelt Electric Snowmelt Pool Spa
Existing 865.00 sqft
To be Removed 0.00 sgft
Existing to Remain 865.00 sqft 0.00 sqft 0.00 sqft 0.00 sqft
New 140.00 sqft
New(exempt)
Total on site 1005.00 sgft 0.00 sgft 0.00 sqft 0.00 sqft
Total Snowmelt on site 1005.00 sqft
Boiler Efficiency 90.6% 100% 75.0% 75.0%
Mitigation Fee $5,253.86
Total Fee for Mitigation:4r1
B. ON-SITE RENEWABLE CREDITS
Supplemental System REMP Credit
Use PV Worksheet Photovoltaic System $ 42,641.88
Use Thermal Worksheet Hot Water Panels $Use GSHP Cert Ground Source Heat Pump $ -
Other Approved System $ -
Total Mitigation Credits: 42461114801
Onsite Renewable Offsets: How many Kilo Watts of PV(solar electric)would 1 need? 0.77
or How many square feet of SHW(solar hot water)would I need? 23.39
R-REMP Fee: $ -
Amount Previously Paid on This Permit: $ -
TOTAL R-REMP FEE : $ -
Refund(includes minus$750): $C. PREPARED BY: Date: 5/19/2017
Print Name: David Rybak
Signature: A....,
�--�
Phone&EMail: 925 1125 dave@daverybak.com
REVIEWED: TF Date: 7/20/17
Received
5/31/17
PV WORKSHEET
City of Aspen Version 11.1 Updated March 28 2017
PROJECT ADDRESS: 1008 E.Hopkins Ave.
Parcel ID#: 2737 18 125 001 Permit Number:
Collector Solar
Aspect,Degress Collector Tilt, Orientation
from True South Degrees From Adjustment DC side capacity Inverter capacity kW for kW Mitigation
Horizontal Factor (kW) (kW) credit Credit
Collector Group 1 75.5 45 83.00% 2.4 4.8 2.4 1.99 kW
Collector Group 2 75.5 14 87.90% 4.8 4.8 4.8 4.22 kW
Collector Group 3 87.00% 0 0.00 kW
Collector Group 4 87.00% 0 0.00 kW
Collector Group 5 87.00% 0 0.00 kW
Collector Group 6 87.00% 0 0.00 kW
Collector Group 7 87.00% 0 0.00 kW
Collector Group 8 87.00% 0 0.00 kW
Collector Group 9 87.00% 0 0.00 kW
Collector Group 10 87.00% 0 0.00 kW
Collector Group 11 87.00% 0 0.00 kW
Collector Group 12 87.00% 0 0.00 kW
Collector Group 13 87.00% 0 0.00 kW
Collector Group 14 87.00% 0 0.00 kW
Collector Group 15 87.00% 0 0.00 kW
Collector Group 16 87.00% 0 0.00 kW
Collector Group 17 87.00% 0 0.00 kW
Collector Group 18 87.00% 0 0.00 kW
Collector Group 19 87.00% 0 0.00 kW
Collector Group 20'' 87.00% 0 0.00 kW
Total: 6.21 kW
$Mitigation Credit: $ 42,641.88
Instructions:
1) Determine how many collector groups you have.Groups are used to differentiate between collectors
(panels)with different tilts,aspects,sizing,or inverters.If all your collectors are installed similarily,you
might have just one group.
2) Enter the aspect and tilt for each group.The solar orientation adjustment factor is automatically calculated.
3) DC side capacity is the total labled panel output kW in a group.
4) Inverter capacity is the recommended input power in kW of your inverter(s).
5) You will be given credit for the lesser of the labeled panel output or the inverter.
6) The kW for credit is multiplied by the solar orientation adjustment factor to get kW mitigation credit.
7) The kW mitigation credit is totalled and multiplied by$6865.32/kW to get the$Mitigation Credit
8) The mitigation credit will be automatically entered into your RREMP or CREMP form.If your project has both RREMP and
CREMP,it will automatically divide the credits up,with priority given to mitigating the CREMP fee.
PREPARED BY: Date: 5/19/2017
Print Name: David Rybak
Signature: 0.--..0.--..."1I
1 A., 1
Phone&EMail: 925-1125 dave@dave ak.com
REVIEWED: Date:
Received
5/31/17
i .4
. 4 . .
. , .
' •%I
, .,.. .
111 v
111: 111 .-•,•
,...• .
.--:
• .
.
r . ,.....
4,..
, .:. ••••i---
. ,
St\INAIMPI Mk
1
..:
- - -• lift T BOILER t
. ..., ..., •
• 4. . .......„
.................._......
._.
. ...
i k
..
. ,.
,
Aill • .-
_ - it ...,.;,
t.w ' -e"Ifi •
. •
.... •
.
t
. .
.
•
, . 1....• • . ENERGY STAR
, . . ,
...immi.,.................11
!. .
1 . ,••
4 'lb
I I S.
lir 0
Pill III
, .
OWL g los I
(I
1 i. .
I i 1
Al
. .
Li
111 4. . $
Cl:
.. ‘
. . ,
0
.. .
4....A..,....
)
1.11
A I.
. 1 .
. ;
. .
•
P ... .
a . ' •
. • 1,,
„
t ,
egillil
: •:.
• k . • ,s
Ty& •
, .. ,
. ,
1111
. ... _,; .
• , 1 ,_ .
.,. .
. .
. _
. ,
. . .. .
, s
s
... ,
. , ..
....
, . :...
. ..
.I •it
....
lige
Pi . ..
A . •iii.,,,
I
.... . :
. . .. .i,. .
. .. . .
. 'Ilit
. „go • , .._
. ... -
- 4 friegiC
46,
.. 1
•
a,. , . .. .
. _ .
. .. .
.1 .
, .
\ . ,
. . ,. ..•....
...
t$ • ,t . ,
•0 , 1•. . ,..
I •
i P I. 1:1 gip
a`
4 .. .
. ...i.
...- - 4stivNSrt til)
VA IIIL #
.•.. „,
_ . .
iso ,.....010111111"
..•
dlior
iii, , 'NI.' . • , . -.*
ii-1.4160i •
000
- •'
.. AI: ' • . ,
. .
• e..;...te • . . .* I. .
.
- .. . . ._ .. , ,., . . . . .. ,- . - . • . — _ ,• •
lir • 2" .•
'
*• - .:lt
•i• .00
• • Received
5/31/17
: .,,,z . :,.
. r_. •
t .,., , .2,
..„ , ../.. . ,..,.
. . . ..
, ,
• . ..,
_ __. ,,,,._:::
. , ,,,... _ ,.:.
„.,
Based i•
..
:1
... , ..
.,„
tr
I it'':.�:.
, .
on standard U.S. Government tests
EllERGIG U I DE • ' 4
Triangle Tube
•
Boiler Gas
PRESTIGE
All Models
` Je
EnergyEfficiencyof thisCom are the p � .
Bu rs Before YouyBoiler with Othe
, ,
This Model's Efficiency 40,,, '
96.0 AFUE ENERGY STAR
Energy
efficiency range .
of all similar models
Least Most
Efficient Efficient ..
80.0 90.6
The energy efficiency rating of this model was not available at the time the range was
published. tt .
The AFUE, Annual FUEL Utilization Efficiency. is a measure of energy efficiency for
tfurnaces and boilers Only boilers fueled by gas are used in this scale.
Gas Boilers that have higher AFUEs are more energy
efficient.
Federal law requires the seller or installer of this appliance to make available a fact sheet
or directory giving further information about the efficiency and operating cost of this
equipmentI.
Ask for this information o
Important Removal of this label before consumer purchase violates the Federal Trade Commission's Appliance (r:2
Labeling Rule (16 C F R Part 305)
1
ali .
.. .
- .
. 1 �
. ,,
:,
. , . ,
. ...
. ,
Received
,. 5/31/17