Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
File Documents.250 S Original St.0294.2017 (16).ARBK
DHW tanks AWARNING: These installation instructions may only be used by trained fitters and service technicians.Read all instructions before installing.Perform steps exactly in the order given.Failure to follow these instructions can result in severe injury,death or property damage. • LOW-LEAD O uv■..I CERTIFIED' www.ahritlirecto"rg Installation and Maintenance Instructions Logalux LT160/1 LT200/1 LT300/1 0 I . IVED Read carefully before installation and servicing. B u d e ru s -_---- , :, NT Contents Contents 1 Safety Considerations and Symbol Descriptions 3 9 Maintenance 15 1.1 Key to symbols 3 9.1 Preparing the DHW tank for cleaning 15 1.2 Safety instructions 3 9.2 Descaling/cleaning the tank 15 1.3 Instructions for the owner and operator 4 9.3 Checking the magnesium anode 16 9.3.1 Testing with the anode tester 16 9.3.2 Visual check 16 2 Product Information 5 9.3.3 Replacing the magnesium anode 16 2.1 Scope of delivery 5 9.4 Startup after maintenance 17 2.2 Designated use 5 2.3 Product Information 6 2.4 Data plate 6 10 Spare Parts 18 2.5 Pressure drop curve of heating coil 6 2.6 Technical Data 7 2.7 Physical and connection dimensions 8 3 Standards,regulations and directives 9 4 Moving the tank 9 5 Installation 10 5.1 Tank installation 10 5.1.1 Requirements for installation location 10 5.1.2 Wall clearances 10 5.1.3 Positioning the tank 10 5.2 Water connections 11 5.2.1 Connecting the tank on the water side 11 5.2.2 Installing B-kit components 12 5.2.3 Installing a T&P safety valve (provided by the customer) 12 5.3 Install a tank water temperature sensor(accessory) or aquastat(accessory) 12 5.3.1 Logamatic controller 12 5.3.2 Installing the DHW tank temperature sensor 12 5.3.3 Installing the aquastat 13 5.3.4 Fitting the thermal insulation and front panel 13 6 Start-up procedure 14 6.1 Commissioning the DHW tank 14 7 Shutdown 14 7.1 Shutting down the tank 14 7.2 Shutting down the heating system when there is a risk of frost 14 8 Environmental Protection/Disposal 14 E EVE I) 01/10/2018 Buderus 4 p 2 Logalux LT160/1 I LT200/1 I LT300/1-6 720 811745 263 0 c BUILDING EPARTMENT Safety Considerations and Symbol Descriptions allI Function 1 Safety Considerations and Symbol Descriptions ► To ensure that the tank functions properly,heed these installation and maintenance instructions. 1.1 Key to symbols ► Never close the blow-off line of the T&P safety valve. Warnings For safety reasons,water may escape during heating. Warnings in this document are indicated by a warning Danger from electric shock I triangle printed against a gray background. ► Only electricians may work on the electrical system. • Keywords at the start of a warning indicate the type and ► Before performing electrical work,disconnect the power cable and seriousness of the ensuing risk if measures to prevent secure the unit against unintentional reconnection. the risk are not taken. ► Ensure the system has been disconnected from the power supply. Risk of scalding at the hot water draw-off point The following keywords are defined and can be used in this document: ► When the DHW tank is in operation,temperatures in excess of 122°F • NOTICE is used to address practices not related to personal injury. (50°C)can occur.To limit the temperature at the tap,install a • CAUTION indicates a hazardous situation which,if not avoided, thermostatic DHW mixing valve. could result in minor to moderate injury. ► Water heated for washing the laundry,dishes and for other cleaning • WARNING indicates a hazardous situation which,if not avoided, purposes can cause scalding and permanent injuries. could result in death or serious injury. ► Children,elderly,and mentally impaired persons are more likely to • DANGER indicates a hazardous situation which,if not avoided,could be permanently injured by hot water.Never leave such individuals in result in death or serious injury. the tub or shower unattended under any circumstances.Children Important Information must not be allowed to operate hot water faucets themselves or to fill a bathtub. This symbol indicates important information where ► If the building has occupants in the above groups who operate hot • 1 there is no risk to people or property. water faucets,or state laws/local ordinances stipulate specific water temperatures,take the following precautions: - Use the lowest possible temperature setting. Additional symbols - To prevent scalding,install a tempering device,such as an automatic mixing valve,at hot water tap or water heater.Select and install the automatic mixing valve in accordance with the ► Sequence of steps valve manufacturer's recommendations and instructions. 4 Cross-reference to another part of the document ► Water exiting from drain valves can be extremely hot.To avoid • Listing/list entry injuries: - Listing/list entry(2nd level) - Check that all connections are tight. Table 1 - Direct exiting water away from people. ► Measures must be taken to protect against excessive temperature 1.2 Safety instructions and pressure!Installation of a T&P safety valve is required. Read all instructions before installing.Perform the steps in the indicated The chart below shows the relationship between water temperature and sequence.Have the DHW tank inspected by a trained service technician time until there is a risk of scalding.It can be used as the basis for at least once every year.Failure to comply with these instructions can determining the safest water temperature for your application. result in severe,possibly fatal,personal injury as well as damage to property and equipment. Installation and servicing ► Risk of fire from soldering and brazing! Take appropriate safety measures when soldering and brazing as the thermal insulation is flammable. ► Ensure that only a licensed contractor installs or services the DHW tank. ► Use installation material with adequate temperature stability. Forbidden: Connection of the potentiostat for an impressed current anode to the magnesium anode installed in a storage tank is absolutely forbidden! This would destroy the tank!The warranty would be voided. Installation and commissioning ► Have an electrician connectthe electrical system.The wiring diagram must be followed.► Do not install this device in rooms with a high moisture level RECEIVED (e.g.bathrooms,saunas). 01/10/2018 Buderus Logalux LT160/1 I LT200/1 I LT300/1-6 720 811 745(2017/07) ASPEN 3 BUILDING DEPARTMENT Safety Considerations and Symbol Descriptions Temperature me to severe sca , 1.3 Instructions for the owner and operator 120°F(48°C) >5 min WARNING:Risk of scalding at the taps! 125°F(51°C) 1.5...2 min I There is a risk of scalding at the taps if the tank 130°F(54°C) -30 s • temperature is set above 122°F(50°C)and during 135°F(57°C) -10 s thermal disinfection. 140°F(60°C) <5 s ► Advise users that they should draw off only mixed 145°F(62°C) <3 s water.Otherwise,install a thermostatic DHW mixing 150°F(65°C) -1.5 s valve. 155°F(68°C) -1 s Table 2 Time-temperature relationship until there is a risk of scalding NOTICE:Risk of tank damage from excessively high (approximate values)1l I pressure. 1) Source:Moritz,A.R.and Henriques,F.C.,Jr.(1947).Studies of thermal injury. ► Never plug the blow off line of the T&P safety valve. II.The relative importance of time and surface temperature in the causation of cutaneous burns,Am J of Pathol,23,695-720. ► Explain the operation and handling of the heating system and DHW tank,making a particular point of safety-relevant features. To protect against corrosion and ensure compliance with the rules for ► Explain the function and how to check the T&P safety valve. electrical safety,observe the following points: ► Hand all enclosed documents over to the owner/operator. ► Use metal fittings for drinking water heating systems with plastic ► Recommendation for the user:Sign a maintenance and inspection piping. contract with a licensed contractor. ► Use only original accessories from the manufacturer. ► Highlight the following for the user: ► When installation of the tank is complete,inspect the ground - Water may be discharged from the T&P safety valve during heat- conductor(including metal fittings). up Maintenance - The blow-off line on the T&P safety valve must always be kept Customers are advised to: open. ► Sign a maintenance and inspection contract with an authorized - Check that the T&P safety valve operates properly at least once contractor.Inspect and maintain the DHW tank as necessary on a yearly. yearly basis.Service as needed. - The tank must be inspected annually and maintained as required. ► Use only original spare parts. Flooding ► After a flood,do not use the appliance if any part has been submerged.Damage to appliances that have been submerged can be quite severe and pose numerous safety risks. ► An appliance that was subject to flooding must be replaced. RECEIVED 01/10/2018 Buderus 4 Logalux LT160/1 I LT200/1 I LT300/1—6 720 8 1745( DEPARTMENT Product Information 2 2 Product Information 2.1 Scope of delivery • DHW tanks • Installation and Maintenance Instructions • B-KIT d4 O O1 a Q 6 720 810 502-23.1T Fig.1 B-kit [1] Tee 1"xl"x3/4" [2] Temperature and pressure relief valve [3] Cap 344" [4] Drain valve [5] Tee 1'/4"x1"x3/4" [6] Sensor Well [7] Coupling 3/" 2.2 Designated use The tank is designed for heating and storing drinking water.Please observe national,regional,and local codes,regulations,guidelines and standards for drinking water. Install this tank only in sealed unvented hydronic heating systems. Any other purpose is considered improper use.Any resulting damage is excluded from the manufacturer's warranty. Requirements for potable water Unit Water hardness ppm >_36 grain/US gallon >_2.1 °dH >2 pH value >6.5..<9.5 Conductivity pS/cm >_130..< 1500 Table 3 Requirements for potable water RECEIVED 01/10/2018 Buderus Logalux LT160/1 I LT200/1 I LT300/1-6 720 811 745(2017/07) ASPEN 5 BUILDING DEPARTMENT LProduct Information 2.3 Product Information Q 1)7/7 2 5po o � � ® ® :,-.:) ,,,,ii TN 11 DO CD ® 7 6 720 810 502-18.1 T Fig.2 Product Information Item Description 2.5 Pressure drop curve of heating coil 1 Inspection port for service and cleaning 3,5 2 DHW outlet 3• 3 DHW tank return -,7. ,/.' 4 DHW tank supply 7 -c 2,5 5 Recirculation connection(or aquastat installation) x 2 , ''1:. a 6 Tank drain 2 O ' e 1,5 '� 7 Cold water inlet ;'j- 8 Casing,painted sheet metal with rigid polyurethane foam a 1 insulation 0,5 9 Heat exchanger for heating by boiler,smooth enameled tubing • ' 10 Tank,enameled steel 0 4,00 6,00 8,00 10,00 12,00 14,00 11 Electrically insulated magnesium anode installed in inspection Flow rate[gpm] port 6 720 810 502-22.1T Table 4 Product Information Fig.3 Pressure drop diagram 2.4 Data plate [1] LT300/1 The data plate is located at the top rear of the DHW tank. [2] LT200/1 [3] LT160/1 RECEIVED 01/10/2018 Buderus 6 Logalux LT160/1 I LT200/1 I LT300/1-6 720 8 1745(NGDEPARTMENT Product Information 2 2.6 Technical Data Unit LT160/1 LT200/1 LT300/1 Tank capacity Tank capacity(total) gal 42.6 52.5 76 (I) (160) (200) (300) Maximum flow rate gpm 4.3 5.3 7.6 (I/min) (16) (20) (30) Maximum hot temperature °F 203 203 203 (on the domestic hot water side) (°C) (95) (95) (95) Maximum operating pressure DHW psi 150 150 150 (bar) (10.3) (10.3) (10.3) Stand-by heat loss(at 149°F(65°C)hot water temperature and 68°F(20°C) °F/h 0.63 0.63 0.39 room temperature) (K/h) (0.27) (0.25) (0.20) DHW tank performance at: Domestic cold water inlet temperature °F 50 50 50 (°C) (10) (10) (10) Domestic hot water outlet temperature °F 140 140 140 (°C) (60) (60) (60) DHW temperature rise °F 90 90 90 (°C) (50) (50) (50) Heat exchanger supply temperature(heating water) °F 176 176 176 (°C) (80) (80) (80) Flow rate(heating water) gpm 14 14 14 (I/h) (3180) (3180) (3180) Pressure drop(heating water) foh 2.4 2.8 3.2 (mbar) (71) (84) (98) Continuous rating gph 122 128 208 (I/h) (461) (486) (787) gpm 2.03 2.13 3.50 (I/min) (7.7) (8.1) (13.1) Amount that can be drawn off in the first hour gph 163 176 276 (I/h) (614) (667) (1046) Maximum heat input btu/hr 76,086 82,985 126,323 (kW) (22.3) (24.3) (37.0) Heat exchanger Content gal 1.7 1.9 3.2 (I) (6.4) (7.2) (12.1) Surface area ft2 8.72 10.01 16.15 (m2) (0.81) (0.93) (1.50) Maximum heating water temperature °F 230 230 230 (°C) (110) (110) (110) Max.operating pressure,heat exchanger psi 232 232 232 (bar) (16) (16) (16) Table 5 Technical Data RECEIVED 01/10/2018 Buderus Logalux LT160/1 I LT200/1 I LT300/1-6 720 811 745(2017/07) ASPEN 7 BUILDING DEPARTMENT Ira Product Information 2.7 Physical and connection dimensions K / J 111/1 � �•��� � )s..41 1. 3/4" °1" / d .,,,k I. ,sc-'' CD li.Lu1 u_, L 0o 6 720 810 502-19.1T Fig.4 Dimensions and Connections __ ,.,,,,;,. .74rz.7 Descripti Unit LT160/1 I T)A� LT300/1 A Minimum floor weight carrying capacity lb 551 1/7 690 976 2/3 (kg) (250) (313) (443) B Clearance off floor inch 1/2 1/2 1/2 (mm) (12.5) (12.5) (12.5) C Height,storage tank without feet inch 25 3/4 25 3/4 25 3/4 (mm) (656) (656) (656) D Height,cold water inlet inch 3 1/4 3 1/4 3 1/4 (mm) (83) (83) (83) E Height,drain connection inch 31/4 3 1/4 31/4 (mm) (83) (83) (83) f Height,storage tank return connection inch 15 15 15 (mm) (378) (378) (378) G Height,storage tank supply connection inch 15 15 15 (mm) (378) (378) (378) H Height,recirculation connection inch 13 13 13 (mm) (328) (328) (328) I Height,hot water outlet inch 22 3/4 22 3/4 22 3/4 (mm) (578) (578) (578) J Width inch 26 26 26 (mm) (659) (659) (659) K Depth inch 39 451/7 601/2 (mm) (992) (1147) (1537) L Space required in front of storage tank for anode inch 40 40 40 replacement (mm) (1016) (1016) (1016) V Weight,empty lb 185 2331/2 291 (kg) (84) (106) (132) M Weight,full(including heating coil contents) lb 551 1/7 690 976 2/3 (kg) (250) (313) (443) Table 6 Physical and connection dimensions iqo7GovEr 01/10/2018 Buderus 8 Logalux LT160/1 I LT200/1 I LT300/1—6 720 8 1745( O7 RTMENT Standards,regulations and directives a 3 Standards,regulations and directives 4 Moving the tank Observe all national,state,and local codes,regulations WARNING:Risk of injury from carrying heavy loads and • ' and standards applicable to installation and operation of I inadequately securing loads for transport! the tank! • ► Use suitable means of transportation,e.g.a dolly with strap. ► Secure the load against falling. All electrical components must be approved for the USA • ' and Canada. To protect the storage tank during transport: ► Move the DHW tank to its installation location while completely packed. ► Position the dolly at the back of the DHW tank. ► Secure the DHW tank to the means of transportation with a strap. ► Transport the DHW tank to the installation location. ► Remove the DHW tank from the packaging only at the installation location. X • I v� 11 1k1106 Vtil% I/ Fig.5 Transporting with a dolly RECEIVED 01/10/2018 Buderus Logalux LT160/1 I LT200/1 I LT300/1-6 720 811 745(2017/07) ASPEN 9 BUILDING DEPARTMENT 5 Installation 5.1.2 Wall clearances 5 Installation The tank is delivered fully assembled. ► Check that the tank is complete and undamaged. 5.1 Tank installation c E 5.1.1 Requirements for installation location II i. The material for positioning and fastening the floor• 1 standing boiler to the DHW tank is included in the scope of delivery of the boiler-storage tank connecting line. j ANOTICE:Risk of damage from inadequate load-bearing capacity of the supporting substructure or unsuitable �_■� floor surface! -- min 16 in. ► Ensure that the installation area is level and offers I sufficient load-bearing capacity. I I j 6 720 810 502-01.1 T NOTICE:Risk of damage from stress cracking and Fig.6 Recommended minimum wall clearances(illustrative) corrosion!A ► Position the DHW tank in a dry room free from the 5.1.3 Positioning the tank risk of freezing. ► Cut the packaging film on the side opposite the"Tank top"sticker ► Install the tank only in closed-loop,unvented (4 Fig.7). hydronic heating systems. ► Remove only the film you have cut out. ► Never use open,vented expansion vessels for this ► Thread the 4 adjustable feet supplied[1]-0.6...1 inch into the DHW tank. threaded bushings provided for this purpose. ► Remove the wooden corner strips[3]from the tank underside. ANOTICE:If leaks can result in property damage ora drain 2 pan is required by law: ,�`,,.' ► Install an adequate drain pan. ► Follow the installation instructions of the drain pan \ \f manufacturer. —_____, , ikl ► Place the DHW tank on a plinth if there is a risk that water may collect m it at the installation site. ���, ;I I- i'� ► The installation site must be a dry and frost-free room. ► Observe minimum wall clearances at installation location(4 Fig.6). \ I ► Maintain a clearance of 2"(51 mm)from heated pipes and O combustible surfaces. , ° I , 6 720 810 502-02.1 T Fig. 7 Cutting the packaging film and inserting the adjustable feet [1] Adjustable feet [2] Rear end of tank [3] Wooden corner strips [4] Front end of tank ► Tip the DHW tank over on the edge of the pallet and set it on its feet (4 Fig.8). ► Remove the remaining film,bottom and top of packaging and wooden pallet.Raise the front and rear of the DHW tank slightly if necessary to do this. RECEIVED 01/10/2018 Buderus 10 Logalux LT160/1 I LT200/1 I LT300/1-6 720 8 1745(NGDEPARTMENT Installation all > NOTICE:Water damage! IV' ► Connect the drain to the bottom tank connection /�\ o I prior to filling the tank. '�, ► Seal off all unused tank connections. / 1, _, /.\ f � NOTICE:Risk of corrosion from damage to the enamel oA coating! ~� ► Attach connections to the DHW tank only"hand - tight". , tight". ( 5.2.1 Connecting the tank on the water side \\_:. i) /e..._ Fi System example with all recommended valves and shut-offs - (�Fig.10). �� � ► When sizing the heating system expansion vessel,take the volume 6 720 610 502-03.1T of the heating coil in the tank into consideration. ► Install piping runs so that natural circulation is prevented. Fig.8 Positioning the tank If necessary,install check valves. ► Position the DHW tank on a level floor with adequate load-bearing ► Install all pipes free of stress. capacity. ► Attach piping to the tank connections on-site. ► By turning the adjustable feet,incline the tank slightly toward the ► Check all connections for leaks. back(4 Fig.9). AW 10 0 CD ±O ►t dEU EK ION Iil v� / AW ® 2 © 0 EZ M ►4 `I ►t EZ 0 0 0 \� 0110�I O VS .4 `, ►� VS ® 0 0 RS — I M t RS 6 720 810 502-04.1 T EK/EL Fig.9 Leveling the DHW tank(illustrative) . . =O ► Maintain minimum wall clearances. ► Remove the caps from the connections. ► Use Teflon tape or Teflon cord to seal the connections.Do not use EL hemp to seal the connections. 6 720 810 502-05.1T Fig.10 Installation(illustrative) 5.2 Water connections AW DHW outlet DANGER:Risk of injury from contaminated water! EK Cold water inlet I Work carried out without due care for cleanliness EL Tank drain • contaminates the drinking water. EZ Recirculation inlet or aquastat installation RS DHW tank return ► Install in accordance with national standards and VS DHW tank supply guidelines. [1] Storage tank [2] Shutoff valve AWARNING:Risk of fire from soldering and welding! [3] Safety valve ► Take appropriate protective measures when [4] Check valve soldering and welding as the thermal insulation is [5] Tank primary pump combustible(for example,cover the thermal [6] Recirculation pump(optional) insulation). [7] Air eliminator(in main supply) ► Check tank jacket for damage after completing work. [8] Drain valve [9] Backflow preventer [10] Expansion vessel RECEIVED 01/10/2018 Buderus Logalux LT160/1 I LT200/1 I LT300/1-6 720 811 745(2017/07) ASPEN11 BUILDING DEPARTMENT Installation 5.2.2 Installing B-kit components 5.3 Install a tank water temperature sensor(accessory) or aquastat(accessory) �1 The DHW tank temperature sensor or aquastat is used to measure and ���+���c 0 1 monitor the hot water temperature of the DHW tank. Ir . . ° DANGER:Risk of fatal injury from electric shock. IDisconnect electrical power completely from the • heating system and lock the disconnect switch to � ; i © prevent accidental reconnection. . 1 5.3.1 Logamatic controller 6 720 810 502-20.1 T Fig.11 Installing B-kit components If a Logamatic controller is used: ► Install a DHW tank temperature sensor or an aquastat on the DHW [1] Tee 1"x 1"x 3/"(2x)with P&T safety valve tank to measure and monitor the hot water temperature. [2] Aquastat(accessory) [3] Tee with fill and drain valve 5.3.2 Installing the DHW tank temperature sensor 5.2.3 Installing a T&P safety valve(provided by the customer) • Electrical installation and the temperature setting for the ► Install a listed T&P safety valve that is approved for drinking water 1 DHW tank temperature sensor or aquastat are described (>_3/4")in the DHW outlet. in the respective instructions included with the ► The DHW tank must be installed with a new T&P safety valve. controller and/or boiler. ► Ensure that the T&P valve is sized no smaller than the rated tank capacity. ► Take the tank temperature sensor from the scope of delivery of the ► Observe the safety valve installation instructions. control panel(accessories). ► Observe the following when installing the blow-off line for the T&P ► Remove front cover of tank(4 Fig.12[1]). valve: ► To do so,loosen the 4 screws[3]on the sides of the front cover. - The blow-off line must be at least equal to the outlet cross-section ► Remove front cover of tank[1]and the thermal insulation element of the safety valve. [2]. - Route the blow-off line from the T&P valve directly to an adequate drain(maximum length 6 ft(2 m)with no more than two 90°- T 2 elbows). mi. - The blow-off line must terminate at an adequate drain in order to prevent property damage from spillage. - Check that the T&P safety valve operates properly at least once 4�_ „ annually. ► Never plug the blow-off line.During heating,water may be ���� ' ; :`` A discharged for operational reasons at any time. ..."""" A u6,4,10 ' - ""� 6 720 810 502-06.2T Fig.12 Removing the front panel and thermal insulation [1] Front cover of tank [2] Thermal insulation element [3] Attachment screws A conduit is encapsulated in the tank's foam thermal insulation;the DHW tank temperature sensor can be inserted here. ► Insert the DHW tank temperature sensor(4 Fig.13[1])into the conduit[2]at the rear of the tank. ► For a type LT300/1:Extend sensor lead with an extension cable(not included in scope of delivery)and push toward the front. ► Fit the temperature sensor to the sensor clamp as required by its shape. RECEIVED 01/10/2018 Buderus 12 Logalux LT160/1 I LT200/1 I LT300/1-6 720 8 1745(NGDEPARTMENT Installation an 5.3.4 Fitting the thermal insulation and front panel 0 © ► Place the thermal insulation element(4 Fig.15[2])in front of the handhole cover. ► Replace front cover of tank[1]and fasten with 4 screws[3]. 0 7 ..t. 1 , 0 ._,_. ig 6 720 810 502-07.1T Fig.13 Fitting sensors --\ [1] Temperature sensor [2] Conduits 3 6 720 810 502-08.21 • To ensure reliable temperature transmission: Fig.15 Fitting the thermal insulation and front cover 1 ► Ensure good contact of the sensor surfaces in the sensor clamp. [1] Front cover of tank [2] Thermal insulation element Electrical installation of the temperature sensor is described in the [3] Attachment screws documents supplied with the controller and the boiler. 5.3.3 Installing the aquastat ► Install the brass sleeve NPT 3/4"and sensor(4 Fig.14[1])that come with the delivery onto the EZ connection. ► Insert the capillary sensor[3]of the aquastat[2]together with the compensating spring[4]into the sensor well. ► Secure the aquastat in the sensor well. 0 ,���) cam O \ liti-C4;i 0 \ I Cv,yr Ash ,___=_, ,, % % .0. 8,0 502.2, Fig.14 Installing the aquastat [1] Sensor Well [2] Aquastat [3] Capillary sensor [4] Compensating spring [5] Attachment screws RECEIVED 01/10/2018 Buderus Logalux LT160/1 I LT200/1 I LT300/1-6 720 811 745(2017/07) ASPEN13 BUILDING DEPARTMENT Start-up procedure 6 Start-up procedure 7 Shutdown NOTICE:Risk of equipment damage from excess A NOTICE:Risk of tank damage from residual moisture! pressure! To prevent corrosion from residual moisture: Excessive pressure can result in stress cracks in the ► Dry the interior thoroughly(e.g.with hot air). enamel coating. ► Leave the handhole cover open. ► Never plug the blow-off line of the T&P safety valve. 7.1 Shutting down the tank 6.1 Commissioning the DHW tank ► Switch off the temperature controller at the control unit. Have the installer of the heating system or a qualified contractor ► Switch off the heating system emergency shutoff switch,or commission the equipment. disengage the heating system circuit breaker. ► Commission the boiler and additional accessories in accordance with WARNING:Risk of scalding from hot water! manufacturer's instructions or the appropriate installation and ► Let the tank cool down sufficiently. operating instructions. Use only drinking water to check the DHW tank for leaks.• • 1 The test pressure on the DHW side must not exceed Close the cold water inlet shutoff valve. 150 psi(10.3 bar). ► Drain the DHW tank by means of the drain valve.To do so,open the highest faucet. To bleed the DHW tank: ► Close the shut-off valves to and from the boiler. ► Open the highest faucet. ► Depressurize the heat exchanger. ► Open the cold water inlet shut-off valve. ► Drain and blow out the heat exchanger. ► Dry the interior thoroughly(e.g.with hot air). Before commissioning: ► Leave the handhole cover open. ► Flush the DHW tank and piping thoroughly. ► Verify that the boiler,DHW tank and piping are filled with water. 7.2 Shutting down the heating system when there is a Open the air bleeder valve for this purpose. risk of frost ► Check all connections,piping and the inspection port for leaks. ► Shut down the heating system and the DHW tank as shown in Chapter 7.1. Fully drain the tank-even the lowest section of the tank 1 and the heating coil. 1 8 Environmental Protection/Disposal Environmental protection is one of the fundamental company policies of the Bosch Group. Quality of products,efficiency and environmental protection are equally important objectives for us.Environmental protection laws and regulations are strictly observed. To protect the environment,we use the best possible technology and materials,taking into account economic points of view. Packaging For the packaging,we participate in the country-specific recycling systems,which guarantee optimal recycling.All packaging materials used are environmentally-friendly and recyclable. Old electrical and electronic appliances Electrical or electronic devices that are no longer ' serviceable must be collected separately and sent for environmentally compatible recycling(in accordance with the European Waste Electrical and Electronic - Equipment Directive). To dispose of old electrical or electronic devi es, o should use the return and collection sysR vED in the country concerned. !! 01/10/2018 Buderus 14 Logalux LT160/1 I LT200/1 I LT300/1-6 720 8 1745(261E RTMENT Maintenance AM 9.2 Descaling/cleaning the tank 9 Maintenance ► Check the DHW tank interior for scale deposits(calcium). ► Allow the DHW tank to cool down sufficiently before performing any maintenance. NOTICE:Risk of tank damage due to damaged enamel. ► Remedy all faults immediately. I ► Never use hard objects or tools with sharp edges to ► Use original spare parts only! • , clean the interior of the tank ► The tank must be inspected annually and maintained as required. ► Check the T&P safety valve annually. If scale deposits have formed in the DHW tank: ► Hose down the interior of the tank with a"high-pressure" 9.1 Preparing the DHW tank for cleaning (-58...72.5 psi(-4...5 bar))jet of cold water(4 Fig.17). AIWARNING:Risk of scalding from hot water! 1• You can increase the cleaning effect by heating up the Hot water can cause scalding. heat exchanger in the drained tank before spraying out. ► Prior to cleaning,allow the DHW tank to cool down The thermal shock effect releases scale deposits more sufficiently. easily from the coil-type heat exchanger. ► Disconnect electrical power from the heating system. ► Use a wet/dry vacuum with a plastic suction pipe to remove any ► Remove front cover of tank(4 Fig.12[1],page 12). residues. ► To do so,loosen the 4 screws[3]on the sides of the front cover. If extremely encrusted scale deposits have formed in the DHW tank: ► Remove front cover of tank[1]and the thermal insulation element ► Hire someone to perform the chemical cleaning. [2]. ► Drain the DHW tank. WARNING:Danger from improper use of the cleanser. ► To do so,close the shut-off valve for cold water inlet and the open I ► Have a qualified contractor carry out the chemical drain valve. • cleaning operation. ► To vent the system,open the air vent valve or the highest faucet. 1 © 3 ® NOTICE: The enamel layer may be damaged if the acid is too strong. • ► Have a qualified contractor carry out the chemical 7 cleaning operation. o - -� r�nmro��" 1 6,nmm-- Q�nm�— _" • o 'C.f.: r-=-, c ------\,. —_- Ono �l0 6 720 810 502-10.1 T • Fig.16 Removing the cleanout cover [1] Hex bolts ----------- = [2] Handhole cover [3] Handhole cover gasket 6 720 810 502-09.1T [4] Magnesium anode Fig. 17 Hosing down the interior of the DHW tank ► Unscrew the hex bolts(4 Fig.16[1])from the handhole cover[2]. ► Remove the handhole cover together with the handhole cover gasket [3]and the magnesium anode[4]from the DHW tank. RFCEIVED ED 01/10/2018 Buderus Logalux LT160/1 I LT200/1 I LT300/1-6 720 811 745(2017/07) ASPEN15 BUILDING DEPARTMENT Maintenance 9.3 Checking the magnesium anode The magnesium anode is a sacrificial anode which is consumed during operation of the DHW tank. If the magnesium anode is not serviced properly,the • 1 warranty is void. Annual service records must be kept in a safe location and submitted together with the original purchase O receipt in the event of a warranty claim. u. To determine whether the magnesium anode must be replaced: ► Check the magnesium anode annually. mA O The surface of the magnesium anode must be free of deposits.The ' t magnesium anode must be replaced when: • Deposits have formed o • The surface area has increased as the result of deposits • Diameter is reduced to<5/8"(15 mm) 0 Certain installations may require more frequent replacement of the © I magnesium anode rod: !ME • Recirculation connection U 0 U i • Poor water quality milt = • Galvanic/electrolytic corrosion • • High flow rate 0 In the event of poor water quality it is recommended that a water treatment professional be consulted for water treatment options. Never bring the magnesium anode surface in contact 6 720 804 390-01.1ITL • 1 with oil or grease. Fig.18 Measuring the anode current ► Keep everything clean. [1] Red cable [2] Screw for ground wire 9.3.1 Testing with the anode tester [3] Handhole cover We recommend that the protection current be measured annually with [4] Magnesium anode the aid of an anode tester.The anode tester is available as an accessory. [5] Thread [6] Ground wire Follow the operating instructions for the anode tester. [7] Black cable • 1 9.3.2 Visual check Never bring the magnesium anode surface into contact • Insulated installation of the magnesium anode is a prerequisite for use of 1 with oil or grease. an anode tester to measure the protection current(4 Fig.18). ► Keep everything clean. The protection current can be measured only with a water-filled storage tank. ► Prepare the DHW tank for removal of the handhole cover ► Ensure proper contact of the connecting terminals. (4 Chapter 9.1,page 15). ► Connect terminals to shiny metal surfaces only. • Remove the handhole cover(4 Fig.16,page 15). ► Loosen the ground wire[6](contact cable between the sacrificial ► Check the magnesium anode. anode and storage tank)at one of the two connection points. If the diameter is reduced to<5/8"(15 mm): ► Attach red cable[1]to the sacrificial anode. ► Replace the magnesium anode. ► Attach black cable[7]to the storage tank. 9.3.3 Replacing the magnesium anode ► If the ground wire has a plug:Attach red cable[1]to the threads of ► Unscrew the M8 nut(4 Fig.19[1])to release the eyelet of the the magnesium anode[5].Remove the ground wire[6]for the ground wire[3]. measurement. ► Unscrew the M8 nut[4]. ► Replace magnesium anode if the anode current is<0.3 mA. ► Remove the magnesium anode[10]from the handhole cover[8]. ► After every test,it is essential that the ground wire[6]always be ► Replace the magnesium anode. reattached properly. ► Fit the new magnesium anode together with all small parts supplied with it as shown in Fig. 19. RECEIVED 01/10/2018 Buderus 16 Logalux LT160/1 I LT200/1 I LT300/1-6 720 8 1745(NGDEPARTMENT IMaintenance tig V ll^` 1O 9.4 Startup after maintenance NOTICE:Risk of system damage from faulty gasket! OTo prevent leaks on the DHW tank: O • ► Use a new handhole cover gasket[4]after every o maintenance. 1� 5O ► Refit handhole cover(4 Fig.20[3])with a new handhole cover © gasket[4]. 0 O ► Attach the eyelet of the ground wire[2]with a hex hex bolt[1]and a serrated washer. C� 8 NOTICE:Risk of system damage from corrosion. OTo ensure that the magnesium anode functions •• , properly: ► Fasten the eyelet of the ground wire to the handhole cover with a hex bolt to ensure good electrical conductivity. ► Thread hex bolts[1]into handhole cover[3]"hand-tight". ► Then use a torque wrench to tighten the hex bolts[1]to 18-22 ft lbs/ 1 25-30 Nm. ► Fill the DHW tank and restart the heating system. ► Check all connections and the handhole cover for leaks. 6 720 810 502-11.1T Fig.19 Replacing the magnesium anode 2 3 [1] M8 Nut [2] Serrated washer [3] Eyelet on ground wire [4] M8 Nut _LI0 [5] Serrated washer 11r� [6] Dished washer ° [7] Insulating sleeve T 5,nm"-- � [8] Handhole cover ° [9] Gasket �0�: " — J [10] Magnesium anode 0 ° ��►� � 0 ° 6 720 810 502-12.1T Fig.20 Reinstall handhole cover [1] Hex bolts [2] Eyelet on ground wire [3] Handhole cover [4] Handhole cover gasket ► Reinstall thermal insulation element and front cover of tank (4 Chapter 5.3.4,page 13). RECEIVED 01/10/2018 Buderus Logalux LT160/1 I LT200/1 I LT300/1-6 720 811 745(2017/07) ASPEN17 BUILDING DEPARTMENT Spare Parts i 10 Spare Parts 0 7 �� 15 j 1 I j o . /F- I 15 I /,. / 3 15 4 \i/ l CI ° ____ K .>,; ° ° 0 >. 1 © \� 1 i" �— 12 OO�O . \ • \ AA • 1 ,,,, ,. ,. 3 ..... ?..• N., ...,____ i ..... /111#411* 1,, 2X Q i 4x-M10x25 14 13 2x-M8x25 3 2x-M8 6 720 810 502-13.2T Fig.21 Spare parts for DHW tank Logalux LT160/1 -LT300/1 "US" RECEIVED 01/10/2018 Buderus 18 Logalux LT160/1 I LT200/1 I LT300/1-6 720 8 1745( 7 RTMENT Spare Parts Min besignation Order no. Comments 1 Front LT160-LT300 5 236 320 No longer available 1 Front LT160/1-LT300/1 63 029 650 3 Sheet metal screw St 4.2x13(10x) 7 747 027 696 5 Blanking plate 28x61x6 3 869 300 6 Thermometer 30...80 degrees C 5 236 200 7 Angle bracket G 115/S 105 8 718 570 813 0 8 Washer DIN125 10.5x2(10x) 8 718 571 270 0 9 Screw ISO4017 M10x30 A3K(10x) 7 747 022 050 10 Hexagon screw ISO4014 M 10x55 8.8 A3K 5 090100 11 Threaded stud ISO7434 M10x30 14H A3K 5 584 628 12 Device feet M10x51 mm(Set of 4 pc.) 5 236 440 13 Thermal insulation D260 inspection port 8 718 572 451 0 14 Angle profile rails G215/LT160 5 261230 Only for:LT160/1 NPT,LT160/1 NPT V1 14 Angle profile rails G215/LT200 5 261 232 Only for:LT200/1 NPT,LT200/1 NPT V1 14 Angle profile rails G215/LT300 5 261 234 Only for:LT300/1 NPT,LT300/1 NPT V1 15 Sleeve R3/4x35 63 017 919 15 Sleeve R1x35 63 017 920 15 Sleeve R1 1/4x35 63 017 921 Table 7 Spare parts for DHW tank Logalux LT160/1-LT300/1 "US" RECEIVED 01/10/2018 Buderus Logalux LT160/1 I LT200/1 I LT300/1-6 720 811 745(2017/07) ASPEN19 BUILDING DEPARTMENT ' Spare Parts AIIIII 0 ilk 10 n 15 N 1 2x •/ 4x M10x25 fit.' QV 1 /• . V 2x-M8x25 Apt, I 0 15 I 2x-M8 1 00 /.� 0 1 0 0 15 0 4 .\ / I 1 1 oo 5 H \ . o o // o 1 1� / —1 .4 j 12 • \ ,. p I 1 1 3 1 131 Prlooti, Nt / V 6 720 810 502-14.2T Fig.22 Spare parts for DHW tank Logalux LT160/1-LT300/1 "US" RECEIVED 01/10/2018 Buderus 20 Logalux LT160/1 I LT200/1 I LT300/1-6 720 811 745 BUILDING%E RTMENT Spare Parts 10 resignation Order no. Comments IIIIIIIIIIIF- 2 Front LT160/1-LT300/1 63 029 650 3 Sheet metal screw St 4.2x13(10x) 7 747 027 696 5 Blanking plate 28x61x6 3 869 300 6 Thermometer 30...80 degrees C 5 236 200 7 Angle bracket G 115/S 105 8 718 570 813 0 8 Washer DIN125 10.5x2(10x) 8 718 571 270 0 9 Screw ISO4017 M10x30 A3K(10x) 7 747 022 050 10 Hexagon screw ISO4014 M 10x55 8.8 A3K 5 090 100 12 Device feet M10x51 mm(Set of 4 pc.) 5 236 440 13 Thermal insulation D260 inspection port 8 718 572 451 0 14 Angle profile rails G215/LT160 5 261 230 Only for:LT160/1 NPT V2 14 Angle profile rails G215/LT200 5 261 232 Only for:LT200/1NPT V2 14 Angle profile rails G215/LT300 5 261234 Only for:LT300/1 NPT V2 15 Sleeve R3/4x35 63 017 919 15 Sleeve R1x35 63 017 920 15 Sleeve R1 1/4x35 63 017 921 Table 8 Spare parts for DHW tank Logalux LT160/1-LT300/1 "US" RECEIVED 01/10/2018 Buderus Logalux LT160/1 I LT200/1 I LT300/1-6 720 811 745(2017/07) ASPEN21 BUILDING DEPARTMENT tSpare Parts 1 2 rb 7 11� *� 5 % co A=...: Ut o® of lx o o t'8x % % 1 x 10x Q 8x25x2 10x 9 © 10x A8,4 A3K DIN6798 10x 0 M8 A3K ISO4032 10x A8,4 A3K DIN125 rJ (1 (-3 10x A10,5 A3K DIN6798 �J\ lisp . . ° \ �Ccice/ �\\i\ \ CI �..�� / i • \\ o \ 11 \\ O \ W \ \ i 1 j,. � © 13 414 L_____ gi 6 720 810 502-15.1 T Fig.23 Spare parts for DHW tank Logalux LT160/1-LT300/1 "US" . CEi '23 Ems% 01/10/2018 Buderus p 22 Logalux LT160/1 I LT200/1 I LT300/1-6 720 811745 21 0 C N BUILDING EPARTMENT Spare Parts MgII besignation Order no. Comments 1 Sacrificial anode D33x400 mm 8 718 571 568 0 Only for:LT160/1 NPT,LT160/1 NPTV1,LT160/1 NPTV2 1 Sacrificial anode D33x500 mm 8 718 571 569 0 Only for:LT200/1 NPT,LT200/1 NPT V1,LT200/1 NPT V2 1 Sacrificial anode D33x700 mm 8 718 571 570 0 Only for:LT300/1 NPT,LT300/1 NPT V1,LT300/1 NPTV2 2 Mounting kit,magn.anodes insulated 10 pc. 5 264 278 3 Thread-forming screws M10x25 set(8x) 7 747 005 744 4 Ground wire insulated for sacrificial anode 63 037 168 5 Manhole cover D210 mm and stud bolt 63 014 370 Only for: LT160/1 NPT,LT160/1 NPT V1(<06/2007) LT200/1 NPT,LT200/1 NPT V1(<06/2007) LT300/1 NPT,LT300/1 NPT V1(<06/2007) 5 �Manhole cover DN 120 LT/L 7 747 004 730 Only for: LT160/1 NPT V2(>07/2007) LT160/1 NPT V2(>07/2007) LT160/1 NPT V2(>07/2007) 6 Sealing ring 120x152x10 mm 63 043 454 Only for: LT160/1 NPT,LT160/1 NPT V1(<06/2007) LT200/1 NPT,LT200/1 NPT V1(<06/2007) LT300/1 NPT,LT300/1 NPT V1(<06/2007) 6 0-ring 120.02x6.99-N 8 718 572 538 0 Only for: LT160/1 NPT V2(>07/2007) LT160/1 NPT V2(>07/2007) LT160/1 NPT V2(>07/2007) 11 Support contact sensor 63 038 417 13 Sensor extension cable kit for LT300 5 118 760 Only for:LT300/1 NPT,LT300/1 NPT V1,LT300/1 NPT V2 Table 9 Spare parts for DHW tank Logalux LT160/1-LT300/1 "US" RECEIVED 01/10/2018 Buderus Logalux LT160/1 I LT200/1 I LT300/1-6 720 811 745(2017/07) ASPEN23 BUILDING DEPARTMENT United States and Canada Bosch Thermotechnology Corp. 50 Wentworth Avenue Londonderry,NH 03053 Tel.603-552-1100 Fax 603-965-7581 www.buderus.us U.S.A. Products manufactured by Bosch Thermotechnik GmbH Sophienstrasse 30-32 D-35576 Wetzlar www.bosch thermotechnology.com ij Bosch Thermotechnology Corp.reserves the right to make changes without notice due to continuing 01/10/2 018 engineering and technological advances. B u d e rq k'la IV BUILDING DEPARTMENT