TWINE' Submittal Prepared For: Date:April 14, 2017 Henderson Engineers Customer P.O. Number: Customer Project Number: Sold To: Job Number: Pacific Sheet Metal Job Name: Louis Vuitton Aspen CARBONDALE, CO 81623 Trane U.S. Inc. dba Trane is pleased to provide the enclosed submittal for your review and approval. Product Summary Qty Product 1 3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop TAG: RTU-1 Notes • Current estimated production time is 4 weeks. • Per the submittal comments, RTU was reselected at design altitude, airflow, and entering air conditions. • Per submittal comments, convenience outlet was changed to unpowered. • Per submittal comments, smoke detector is factory installed. • Fan performance table shown after unit performance data. The attached information describes the equipment we propose to furnish for this project, and is submitted for your approval. Product performance and submittal data is valid for a period of 6 months from the date of submittal generation. If six months or more has elapsed Mark Redman, BJS between submittal generation and equipment release, the product Trane performance and submittal data will need to be verified. It is the customer's responsibility to obtain such verification. 445 Bryant St., Suite 5 Denver, CO 80204-4800 Phone: (303) 228-3300 Fax: (303) 228-2828 J:IJOBS1111149750171S-Louis Vuitton Aspen RTU Replacements RTU-1 R1.doc Received i/05/2017 10:27:52 AM Table Of Contents Product Summary 1 3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop (Item Al) 3 Tag Data 3 Product Data 3 Performance Data 3 Mechanical Specifications 5 Unit Dimensions 9 Weight, Clearance& Rigging Diagram 13 Accessory 15 Field Wiring 19 Field Installed Options - Part/Order Number Summary 21 3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop 21 Received W05/2017 10:27:52 AM Louis Vuitton Aspen April 14,2017 Tag Data - 3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop (Qty: 1) Item Tag(s) Qty Description Model Number Al RTU-1 1 3-10 Ton R410A PKGD Unitary Gas/Electric YSC120F3RZA--D6B1A1A000C Product Data - 3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: Al Qty: 1 Tag(s): RTU-1 DX cooling, gas heat Standard efficiency Convertible configuration 10 Ton Major design sequence 208-230/60/3 Microprocessor controls 3ph High gas heat stainless steel heat exchanger Economizer Dry Bulb 0-100% with Barometric Relief Single Zone VAV Standard panel/2 in pleated filters Mery 8 Standard condenser coil w/hail guard Through the base electrical 3ph Non-fused disconnect Unpowered convenience outlet(3ph units) Return/supply air smoke detector 3ph CO2 wall mounted, field sensor kit (Fld) Programmable zone sensor (Fld) Performance Data - 3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Tags RTU-1 Design Airflow (cfm) 4715 Airflow Application Downflow Elevation (ft) 7800.00 Cooling Entering DB (F) 74.70 Cooling Entering WB (F) 52.90 Ent Air Relative Humidity (%) 26.44 Ambient Temp (F) 95.00 Evap Coil Leaving Air Temp (DB) (F) 49.34 Evap Coil Leaving Air Temp (WB) (F) 43.08 Cooling Leaving Unit DB (F) 50.95 Cooling Leaving Unit WB (F) 43.76 Gross Total Capacity (MBh) 100.34 Gross Sensible Capacity(MBh) 100.13 Gross Latent Capacity (MBh) 0.21 Net Total Capacity (MBh) 93.96 Net Sensible Capacity(MBh) 93.75 Net Sensible Heat Ratio (Number) 1.00 Heating EAT (F) 63.00 Heating LAT (F) 102.50 Heating Delta T (F) 39.50 Input Heating Capacity (MBh) 172.00 Output Heating Capacity(MBh) 137.60 Output Heating Cap. w/Fan (MBh) 143.98 Component SP (in H2O) 0.526 Field supplied drive kit required None Indoor mtr operating power (bhp) 2.28 Indoor RPM (rpm) 1659 Indoor Motor Power(kW) 1.70 Outdoor Motor Power (kW) 0.69 Compressor Power (kW) 8.69 System Power (kW) 11.08 IPLV @ AHRI (IPLV) 13.5 Receive FLD=Furnished by Trane U.S. Inc.dba Trane/ Equipment Submittal ageof 21 Installed by Others W0 5/2 017 10:2 7:52 AM Louis Vuitton Aspen April 14,2017 Tags RTU-1 MCA(A) 49.60 MOP (A) 60.00 _ Compressor 1 RLA(A) 19.60 Compressor 2 RLA (A) 13.10 Evaporator fan FLA (A) 8.50 Condenser fan FLA (A) 3.50 Evaporator face area (sq ft) 12.36 Evaporator rows (Each) 4.00 Evaporator fin spacing (Per Foot) 192 Evaporator face velocity(ft/min) 381 Min. unit operating weight (Ib) 1124.0 Max. unit operating weight (Ib) 1369.0 Fan motor heat(MBh) 6.38 Dew Point(F) 37.98 Rated capacity(AHRI) (MBh) 113.00 Exhaust fan power(kW) 0.65 Refrig charge (HFC-410A) - ckt 1 (Ib) 5.5 Refrig charge (HFC-410A) - ckt 2 (Ib) 4.2 ASHRAE 90.1 Yes Saturated Suction Temp Circuit 1 (F) 47.19 Saturated Discharge Temp Circuit 1 (F) 119.55 Saturated Suction Temp Circuit 2 (F) 47.65 Saturated Discharge Temp Circuit 2 (F) 119.15 IEER ( ) 13.50 EER @ AHRI Conditions (EER) 11.3 Table 88. Direct drive evaporator fan performance-10 tons with standard efficiency gas heat - YSC120F3,4,W*H high heat downflow airflow External Static Pressure(Inches of Water Gauge) 0.10" 0.20" 0.30" 0.40" 0.50" 0.60" 0.70" 0.80" 0.90" 1.00" CFM RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 3200 1055 0.70 1082 0.79 1109 0.87 1132 0.93 1156 1.01 1180 1.09 1205 1.17 1228 1.25 1252 1.33 1275 1.41 3600 1180 0.98 1205 1.07 1229 1.16 1252 1.25 1272 1.33 1293 1.40 1315 1.49 1337 1.59 1358 1.68 1379 1.77 4000 1305 1.32 1328 1.42 1350 1.52 1372 1.63 1392 1.73 1410 1.80 1429 1.89 1448 1.99 1468 2.09 1488 2.19 4400 1432 1.73 1452 1.84 1473 1.96 1493 2.07 1512 2.19 1530 2.29 1547 2.38 1564 2.47 1581 2.57 1599 2.68 4800 1558 2.22 1577 2.34 1596 2.47 1615 2.59 1633 2.72 1650 2.84 1667 2.96 1683 3.06 1698 3.15 - - External Static Pressure(Inches of Water Gauge) 1.10" 1.20" 1.30" 1.40" 1.50" 1.60" 1.70" 1.80" 1.90" 2.00" CFM RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 3200 1298 1.49 1322 1.59 1348 1.69 1374 1.81 1398 1.91 1421 2.00 1443 2.10 1465 2.20 1488 2.30 1511 2.41 3600 1400 1.86 1421 1.95 1441 2.04 1462 2.14 1483 2.24 1507 2.36 1530 2.48 1552 2.61 1574 2.72 1594 2.83 4000 1507 2.29 1526 2.39 1544 2.49 1563 2.59 1582 2.69 1601 2.79 1619 2.90 1639 3.01 1657 3.13 1678 3.26 4400 1617 2.79 1635 2.91 1652 3.02 1669 3.13 1687 3.23 - - - - - - - - - - Notes: 1. For direct drive evaporator fan speed(rpm),refer to the applicable table in the fan performance section. 2. Data includes pressure drop due to standard filters and wet coils.No accessories or options are included in pressure drop data. 3. To determine static pressure drop due to other options/accessories,refer to the applicable table in the fan performance section. 4. Direct drive fan motor heat(MBh)=2.8623 x fan bhp-0.1504 5. Factory supplied motors,in commercial equipment,are definite purpose motors,specifically designed and tested to operate reliably and continuously at all cataloged conditions.Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure.Our product's warranty will not be affected. FLD=Furnished by Trane U.S. Inc.dba Trane/ Equipment Submittal Ie c e i v� of 21 Installed by Others i/0 5/2 017 10:2 7:52 AM Louis Vuitton Aspen April 14,2017 Mechanical Specifications -3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: Al Qty: 1 Tag(s): RTU-1 General The units shall be convertible airflow. The operating range shall be between 115°F and 0°F in cooling as standard from the factory for units with microprocessor controls. Operating range for units with electromechanical controls shall be between 115°F and 40°F. Cooling performance shall be rated in accordance with ARI testing procedures. All units shall be factory assembled, internally wired, fully charged with R-410A, and 100 percent run tested to check cooling operation, fan and blower rotation, and control sequence before leaving the factory. Wiring internal to the unit shall be colored and numbered for simplified identification. Units shall be cULus listed and labeled, classified in accordance for Central Cooling Air Conditioners. Casing Unit casing shall be constructed of zinc coated, heavy gauge, galvanized steel. Exterior surfaces shall be cleaned, phosphatized, and finished with a weather-resistant baked enamel finish. Unit's surface shall be tested 672 hours in a salt spray test in compliance with ASTM B117. Cabinet construction shall allow for all maintenance on one side of the unit. Service panels shall have lifting handles and be removed and reinstalled by removing two fasteners while providing a water and air tight seal. All exposed vertical panels and top covers in the indoor air section shall be insulated with a cleanable foil-faced, fire-retardant permanent, odorless glass fiber material. The base of the unit shall be insulated with 1/8 inch, foil-faced, closed-cell insulation. All insulation edges shall be either captured or sealed. The unit's base pan shall have no penetrations within the perimeter of the curb other than the raised 1 1/8 inch high downflow supply/return openings to provide an added water integrity precaution, if the condensate drain backs up. The base of the unit shall have provisions for forklift and crane lifting, with forklift capabilities on three sides of the unit. Unit Top The top cover shall be one piece construction or, where seams exist, it shall be double-hemmed and gasket-sealed. The ribbed top adds extra strength and enhances water removal from unit top. Two-Inch Pleated Filters 2" pleated media filters shall be available on all models. Compressors All units shall have direct-drive, hermetic, scroll type compressors with centrifugal type oil pumps. Motor shall be suction gas-cooled and shall have a voltage utilization range of plus or minus 10 percent of unit nameplate voltage. Internal overloads shall be provided with the scroll compressors. Dual compressors are outstanding for humidity control, light load cooling conditions and system back-up applications. Dual compressors are available on 71/2-10 ton models and allow for efficient cooling utilizing 3-stages of compressor operation for all high efficiency models. Notes: Crankcase heaters are optional on YSC(036, 048, 060, 072, 090, 102, 120); standard on YHC(036, 048, 060, 072, 092, 102, 120). Indoor Fan The following units shall be equipped with a direct drive plenum fan design (T/YSC120F,T/YHC074F, T/YHC092F,T/YHC102F, 120F). Plenum fan design shall include a backward-curved fan wheel along with an external rotor direct drive variable speed indoor motor. All plenum fan designs will have a variable speed adjustment potentiometer located in the control box. 3 to 5 ton units (high efficiency 3-phase with optional motor) are belt driven, FC centrifugal fans with adjustable motor sheaves. 3 to 5 ton units (standard and high efficiency 3-phase) have multispeed, direct drive motors. All 6 to 81/2 ton units(standard efficiency)shall have belt drive motors with an adjustable idler-arm assembly for quick-adjustment to fan belts and motor sheaves. All motors shall be thermally protected. All 10 tons, 6 ton (074), 7'/2 to 81/2(high efficiency) units have variable speed direct drive motors. All indoor fan motors meet the U.S. Energy Policy Act of 1992 (EPACT). Outdoor Fans The outdoor fan shall be direct-drive, statically and dynamically balanced, draw-through in the vertical discharge position. The fan motor shall be permanently lubricated and shall have built-in thermal overload protection. FLD=Furnished by Trane U.S. Inc.dba Trane/ Equipment Submittal Receiv . a of 21 Installed by Others i/0 5/2 017 10:2 7:52 AM Louis Vuitton Aspen April 14,2017 Single Zone VAV -One Zone Variable Air Volume Mode Single zone VAV is designed for use in single zone applications like gymnasiums, auditoriums, manufacturing facilities, retail box stores, and any large open spaces, where there is a lot of diversity in the load profile. Single Zone VAV(SZ VAV)is an ideal replacement to yesterdays constant volume(CV)systems, by reducing operating costs while improving occupant comfort. SZ VAV systems combine Trane application, control and system integration knowledge to exactly match fan speed with cooling and heating loads, regardless of the operating condition. Trane algorithms meet/exceed ASHRAE 90.1-2010, SZ VAV energy-saving recommendations, and those of CA Title 24. The result is an optimized balance between zone temperature control and system energy savings. Depending on your specific application, energy savings can be as much as 20+%. Note: Building system modeling in energy simulation software like TRACE is recommended to evaluate performance improvements for your application. SZ VAV is fully integrated into the ReliaTel Control system and is available today. It provides thesimplest and fastest commissioning in the industry through proven factory-installed, wired, and tested system controllers. All control modules, logic and sensors are factory installed, and tested to assure the highest quality and most reliable system available.This means no special programming of algorithms,or hunting at the jobsite for sensors, boards, etc.that need to be installed in the field. Single zone VAV is a quick and simple solution for many applications and is available from your most trusted rooftop VAV system solution provider-Trane. Evaporator and Condenser Coils Internally finned, 5/16" copper tubes mechanically bonded to a configured aluminum plate fin shall be standard. Evaporator coils are standard for all 3 to 10 ton standard efficiency models. Microchannel condenser coils are standard for all 3 to 10 ton standard efficiency models and 4,5,6, 7.5, 8.5 ton high efficiency models.The microchannel type condenser coil is not offered on the 4 and 5 ton dehumidification model. Due to flat streamlined tubes with small ports, and metallurgical tube-to-fin bond, microchannel coil has better heat transfer performance. Microchannel condenser coil can reduce system refrigerant charge by up to 50% because of smaller internal volume, which leads to better compressor reliability. Compact all-aluminum microchannel coils also help to reduce the unit weight.These all aluminum coils are recyclable. Galvanic corrosion is also minimized due to all aluminum construction. Strong aluminum brazed structure provides better fin protection. In addition, flat streamlined tubes also make microchannel coils more dust resistant and easier to clean. Coils shall be leak tested at the factory to ensure the pressure integrity.The evaporator coil and condenser coil shall be leak tested to 600 psig.The assembled unit shall be leak tested to 465 psig.The condenser coil shall have a patent pending 1+1+1 hybrid coil designed with slight gaps for ease of cleaning.A plastic, dual-sloped, removable and reversible condensate drain pan with through-the-base condensate drain is standard. Tool-less Hail Guards Tool-less, hail protection quality coil guards are available for condenser coil protection. Controls Unit shall be completely factory-wired with necessary controls and contactor pressure lugs or terminal block for power wiring. Unit shall provide an external location for mounting a fused disconnect device. A choice of microprocessor or electromechanical controls shall be available. Microprocessor controls provide for all 24V control functions.The resident control algorithms shall make all heating, cooling, and/or ventilating decisions in response to electronic signals from sensors measuring indoor and outdoor temperatures. The control algorithm maintains accurate temperature control, minimizes drift from set point,and provides better building comfort.A centralized microprocessor shall provide anti-short cycle timing and time delay between compressors to provide a higher level of machine protection. 24-volt electromechanical control circuit shall include control transformer and contactor High Pressure Control All units include High Pressure Cutout as standard. Phase monitor Phase monitor shall provide 100% protection for motors and compressors against problems caused by phase loss, phase imbalance, and phase reversal. Phase monitor is equipped with an LED that provides an ON or FAULT indicator. There are no field adjustments. The module will automatically reset from a fault condition. Refrigerant Circuits Each refrigerant circuit offer thermal expansion valve as standard. Service pressure ports, and refrigerant line filter driers are factory-installed as standard. An area shall be provided for replacement suction line driers. FLD=Furnished by Trane U.S. Inc.dba Trane/ Equipment Submittal Receiv . a of 21 Installed by Others i/0 5/2 017 10:2 7:52 AM Louis Vuitton Aspen April 14,2017 Gas Heating Section The heating section shall have a progressive tubular heat exchanger design using stainless steel burners and corrosion resistant steel throughout. An induced draft combustion blower shall be used to pull the combustion products through the firing tubes. The heater shall use a direct spark ignition (DSI) system. On initial call for heat, the combustion blower shall purge the heat exchanger for 20 seconds before ignition After three unsuccessful ignition attempts,the entire heating system shall be locked out until manually reset at the thermostat/zone sensor. Units shall be suitable for use with natural gas or propane (field-installed kit) and also comply with the California requirement for low NOx emissions (Gas/Electric Only). Powered or Unpowered Convenience Outlet This is a GFCI, 120v/15amp, 2 plug, convenience outlet, either powered or unpowered. When the convenience outlet is powered, a service receptacle disconnect will be available. The convenience outlet is powered from the line side of the disconnect or circuit breaker, and therefore will not be affected by the position of the disconnect or circuit breaker. This option can only be ordered when the Through the Base Electrical with either the Disconnect Switch or Circuit Breaker option is ordered. Economizer This accessory shall be available with or without barometric relief. The assembly includes fully modulating 0-100 percent motor and dampers, minimum position setting, preset linkage, wiring harness with plug, spring return actuator and fixed dry bulb control. The barometric relief shall provide a pressure operated damper that shall be gravity closing and shall prohibit entrance of outside air during the equipment off cycle. Optional solid state or differential enthalpy control shall be available for either factory or field installation. The economizer arrives in the shipping position and shall be moved to the operating position by the installing contractor. Through the Base Electrical Access An electrical service entrance shall be provided allowing electrical access for both control and main power connections inside the curb and through the base of the unit. Option will allow for field installation of liquid-tight conduit and an external field-installed disconnect switch. Through the Base Electrical with Disconnect Switch This 3-pole, molded case, disconnect switch with provisions for through the base electrical connections are available. The disconnect switch will be installed in the unit in a water tight enclosure with access through a swinging door.Wiring will be provided from the switch to the unit high voltage terminal block. The switch will be UL/CSA agency recognized. Note: The disconnect switch will be sized per NEC and UL guidelines but will not be used in place of unit overcurrent protection. Supply and/or Return Air Smoke Detector Smoke detector shall be factory installed photoelectric smoke detector mounted in the return air section (with or without the economizer or motorized damper option),AND/OR in the supply air fan compartment. The detector will be wired for continuous power whenever the unit is energized. Upon detection of smoke, the detector will shut down all unit operations. Local codes may dictate the location of detectors. Note: Due to the shipping position of the economizer or motorized damper, the return air smoke detector will not be completely factory installed. The wiring harness for the detector will be routed and tied off in the fan compartment for shipping. The smoke detector and barometric damper hood will also be installed in a shipping position in the fan compartment. Accessory -CO2 Sensing The CO2 sensor shall have the ability to monitor space occupancy levels within the building by measuring the parts per million of CO2 (Carbon Dioxide) in the air. As the CO2 levels increase, the outside air damper modulates to meet the CO2 space ventilation requirements. Accessory - BAYSENS119 Programmable Zone Temperature Sensor Configured as a Constant Volume Unit The electronic programmable sensor is Auto or Manual changeover with seven day programming. Auto or Manual selection of Fan Auto, Fan On. Programmable sensor has System Off,Auto, Heat, Cool, and Service/LCD indicators as standard. Night setback sensor has up to four programs per day which can be individually configured to occupied or unoccupied. FLD=Furnished by Trane U.S. Inc.dba Trane/ Equipment Submittal Receiv� of 21 Installed by Others i/0 5/2 017 10:2 7:5 3 AM Louis Vuitton Aspen April 14,2017 Trane Single Zone Variable Air Volume Control Sequence of Operation (Precedent 17 Plus) General Standby Mode During normal occupied periods, when there is no space cooling or heating demands, the user will be able to choose Continuous or Cycling supply fan operation. During this period, if the supply fan is operating due to a Continuous Fan Mode selection or due to a ventilation request, the supply fan will operate at 50% of the user selected, application specific, maximum airflow. The unit controls will be compatible with BACnet and LonTalk Building Automation System communication interfaces. Cooling Operation Default Operation: During Cooling operation, the control will monitor the Space Temperature and Space Cooling setpoint and with a PI control algorithm determine if active cooling capacity is required.As the Space Temperature deviates from the Space Cooling Setpoint, the unit controller will calculate an active Discharge Air Cooling setpoint that the economizer(if installed)and compressor outputs will be controlled to meet. This active Discharge Air Cooling setpoint will be calculated between the Space Cooling setpoint and a user adjustable minimum (65F Default for Single Zone Variable Air Volume Control). Once the control determines that a discharge air temperature equal to the user selected minimum (65F Default)is required to meet the space cooling demand, if the space demand continues to increase, the supply fan speed will be allowed to increase above its minimum speed proportionally to meet the additional demand. Alternate Economizer Operation: Under the Default Operation, as described above, the supply fan speed will remain at minimum speed, as determined by the active cooling stages, until the space demand requires an increase in supply airflow. The customer will have the ability to choose to allow the supply fan speed to increase when the economizer is enthalpy enabled in order to realize the maximum cooling capacity of the economizer, prior to energizing compressor outputs, when the space requires active cooling capacity. All cooling capacity demand decisions will function as described in the "Default Operation"section above with the exception of the supply fan speed when the unit has an active cooling demand and the economizer is enthalpy enabled. Heating Operation During Heating operation, the control will monitor the Space Temperature and Space Heating setpoint and with a PI control algorithm determine if active heating capacity is required. As the Space Temperature deviates from the Space Heating Setpoint, the unit controller will increase the supply airflow up to the user selected, application specific, maximum airflow and begin to stage heating outputs (gas or electric)to meet the space demand. The customer will also have the ability to enable Supply Air Tempering control which will allow the unit to bring on one stage of heating when the discharge air temperature falls below the Space Heating Setpoint - 10°F and the unit is operating in a minimum ventilation state with the supply fan running (not actively heating or cooling). The supply fan output will increase to the user selected, application specific, maximum airflow during Supply Air Tempering operation. Supply, Return, and Plenum Air Smoke Detector With this option installed, if smoke is detected, all unit operation will be shut down. Reset will be manual at the unit. In order for the supply air smoke detector or return air smoke detector to properly sense smoke in the supply air stream or the return air stream, the air velocity entering the smoke detector unit must be between 500 -4000 feet per minute. Equipment covered in this manual will develop an airflow velocity that falls within these limits over the entire airflow range specified in the evaporator fan performance table. Supply and/or Return Smoke Detectors may not be used with the Plenum Smoke Detector. FLD=Furnished by Trane U.S. Inc.dba Trane/ Equipment Submittal Receiv . a of 21 Installed by Others i/0 5/2 017 10:2 7:5 3 AM Louis Vuitton Aspen April 14,2017 Unit Dimensions -3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: Al Qty: 1 Tag(s): RTU-1 TOP PANEL EVAPORATOR I SECTION ACCESS PANEL CONDENSER FAN CONDENSATE DRAIN(ALT) 1 3/4"-14 NPT DIA.HOLE 1 --.--- )1 --.--- ) CONDENSER COIL 4 1/4 27 5/8" e r J UNIT CONTROL WIRE 7/8"DIA.HOLE ��� I„� SERVICE GAUGE PORT ACCESS 1 3/8"DIA.HOLE 477/8 � pill �� UNIT POWER WIRE 1/2"NPT GAS CONNECTION � (80MBH&120MBH) 3/4"NPT GAS CONNECTION (150MBH,200MBH&250MBH) CONTROL AND COMPRESSOR ACCESS PANEL PACKAGED GAS/ELECTRICAL THROUGH THE ISOMETRIC VIEW BASE CONDENSATE 4 1/8" 27 5/8" NOTES: 1.THRU-THE-BASE ELECTRICAL IS NOT STANDARD ON ALL UNITS. 2.VERIFY ALL DIMENSIONS WITH INSTALLER DOCUMENTS BEFORE INSTALLATION. t git \ [ k vw i33 32 1/8" SUPPLY RETURN —� . 17 1/2" 9 7/8" 17 1/2" 3 5/8" PLAN VIEW UNIT DIMENSION DRAWING 1 —r— 46 7/8" HORIZONTAL RETURN 32 1/4" AIR FLOW 23 7/8" SUPPLY 24 1/2" , 7. 111111 1 0 0 I I I I O O 9 8 8 5 5/8" �IL�� —19 1/4" 9 3/8"a16 3/4"—=- 3 7/8" 4 1/4" iI II CONDENSATE 5 5/8" 88 5/8" 7 5/8" - - PACKAGED GAS/ELECTRICAL - 53 1/4" DIMENSION DRAWING FLD=Furnished by Trane U.S.Inc.dba Trane/ Equipment Submittal Receiveacj , Installed by Others i/05/2017 10:27:53 AM Louis Vuitton Aspen April 14,2017 Unit Dimensions -3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: Al Qty: 1 Tag(s): RTU-1 ( ®0 RETURN 3/4"-14 DIA HOLE CONDENSATE DRAIN 27 5/8" 4 3/4" ISOMETRIC-PACKAGED COOLING FLD=Furnished by Trane U.S.Inc.dba Trane/ Equipment Submittal Ie c e i vagcJ of 21 Installed by Others i/05/2017 10:27:53 AM Louis Vuitton Aspen April 14,2017 Unit Dimensions -3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop ,, -I:- Item: Al Qty: 1 Tag(s): RTU-1 o o11 1 PANEL III7- 1 ACCESS SIDE o t r CONDENSER COIL SIDE CONDENSER COIL SIDE THROUGH THE BASE ELECTRICAL (SEE NOTE 1 AND 2) 0 23L } 3 3/4" 4 THROUGHTHE BASE CONDENSATE 5 7/8" 5" NOTES: 1.THRU-THE-BASE GAS AND ELECTRICAL IS NOT STANDARD. PANEL VERIFY OPTION IN PRODUCT DATA IN THIS DOCUMENT. ACCESS SIDE 2.VERIFY WEIGHT,CONNECTION,OPTION CONFIGURATION AND ALL DIMENSION WITH INSTALLER DOCUMENTS BEFORE INSTALLATION THRU THE BASE ELECTRICAL PLAN/ISO VIEW DRAWING FLD=Furnished by Trane U.S.Inc.dba Trane/ Equipment Submittal Receiv age of 21 Installed by Others i/05/2017 10:27:53 AM Louis Vuitton Aspen April 14,2017 Unit Dimensions -3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: Al Qty: 1 Tag(s): RTU-1 'ELECTRICAL/GENERAL DATA 'GENERAL (2)(4)(6) HEATING PERFORMANCE Model: YSC120F Oversized Motor HEATING-GENERAL DATA Unit Operating Voltage: 187-253 MCA: N/A : High Model:Unit Primary Voltage: 208 MFS: N/A Heating Heating M MInode(BTU): 250,000/175,000 Unit Secondary Voltage 230 MCB: N/A Heating Output(BTU): 200,000/140,000 Unit Hertz: 60 No.Burners: 5 Unit Phase: 3 No.Stages 2 EER 11.3 Standard Motor Field Installed Oversized Motor 'Gas Inlet Pressure MCA: 50.1 MCA: N/A Natural Gas(Min/Mix): 4.5/14 MFS: 60.0 MFS: N/A LP(Min/Max) 11.0/14.0 MCB: 60.0 MCB: N/A Gas Pipe Connection Size: 3/4" INDOOR MOTOR Standard Motor Oversized Motor Field Installed Oversized Motor Number: 1 Number: N/A Number: N/A Horsepower: 3.8 Horsepower: N/A Horsepower: N/A Motor Speed(RPM): -- Motor Speed(RPM): N/A Motor Speed(RPM): N/A Phase 3 Phase N/A Phase N/A Full Load Amps: 8.5-8.5 Full Load Amps: N/A Full Load Amps: N/A Locked Rotor Amps: _ Locked Rotor Amps: N/A Locked Rotor Amps: N/A COMPRESSOR Circuit 1/2 OUTDOOR MOTOR Number: 2 Number: 1 Horsepower: 4.8/3.7 Horsepower: 0.75 Phase: 3 Motor Speed(RPM): 1100 Rated Load Amps: 19.6/13.1 Phase: 1 Locked Rotor Amps: 136.0/83.0 Full Load Amps: 4.0 Locked Rotor Amps: 9.3 POWER EXHAUST ACCESSORY (3) FILTERS REFRIGERANT (2) (Field Installed Power Exhaust) Type R-410 Phase: N/A Type: Throwaway Horsepower: N/A Furnished: Yes Factory Charge Motor Speed(RPM): N/A Number 4 Circuit#1 5.5 lb Full Load Amps: N/A Recommended 20"x25"x2" Circuit#2 4.2 lb Locked Rotor Amps: N/A NOTES: 1.Maximum(HACR)Circuit Breaker sizing is for installations in the United States only. 2.Refrigerant charge is an approximate value.For a more precise value,see unit nameplate and service instructions. 3.Value does not include Power Exhaust Accessory. 4.Value includes oversized motor. 5.Value does not include Power Exhaust Accessory. 6.EER is rated at AHRI conditions and in accordance with DOE test procedures. FLD=Furnished by Trane U.S.Inc.dba Trane/ Equipment Submittal ReceivegcL2, Installed by Others i/05/2017 10:27:53 AM Louis Vuitton Aspen April 14,2017 Weight, Clearance & Rigging Diagram -3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: Al Qty: 1 Tag(s): RTU-1 INSTALLED ACCESSORIES NET WEIGHT DATA ACCESSORY WEIGHTS ECONOMIZER 36.0 lb MOTORIZED OUTSIDE AIR DAMPER Q r CO MANUAL OUTSIDE AIR DAMPER O BAROMETRIC RELIEF OVERSIZED MOTOR p a(-0:_...--- BELT DRIVE MOTOR � `` POWER EXHAUST p a llllll/��f! 111��� r.y THROUGHT THE BASE ELECTRICAUGAS(FIOPS) 13.0 lb p a UNIT MOUNTED CIRCUIT BREAKER(FIOPS) UNIT MOUNTED DISCONNECT(FIOPS) 5.0 lb POWERED CONVENIENCE OUTLET(FIOPS) !d HINGED DOORS(FIOPS) C( O HAIL GUARD 20.0 lb ����JJJJ SMOKE DETECTOR,SUPPLY/RETURN 12.0 lb PACKAGED GAS/ELECTRICAL NOVAR CONTROL CORNER WEIGHT STAINLESS STEEL HEAT EXCHANGER 6.0 lb REHEAT ROOF CURB BASIC UNIT WEIGHTS CORNER WEIGHTS CENTER OF GRAVITIY SHIPPING NET ( 345.0 lb 0 258.0 lb (E)LENGHT (F)WIDTH 1156.0 lb 1058.0 lb O 242.0 lb 0 213.0 lb 41" 23" NOTE: 1. All weights are approximate. 2. Weights for options that are not list refer to Installation guide. 3. The actual weight are listed on the unit nameplate. 4. Refer to unit nameplate and installation guide for weights before scheduling transportation and installation of unit. 5. The weight shown represents the typical unit operating weight for the configuration selected.Estimated at+/-10%of the nameplate weight.. ,,,,......... ,,,,,,,,p 6. Verify weight,connection,and all dimension with installer documents before installation. 7. Corner weights are given for information only. 8. Net/Shipping weight of optional accessories should be added to unit weight when ordering factory or field installed accessories. � i 411IN , ,,,, '(' -=-;r;--._.._._.---5--7.—_..4---'---- '', E 0 . �'/I F i PACKAGED GAS/ELECTRICAL RIGGING AND CENTER OF GRAVITY FLD=Furnished by Trane U.S.Inc.dba Trane/ Equipment Submittal Receivecge of 21 Installed by Others i/05/2017 10:27:53 AM Louis Vuitton Aspen April 14,2017 Weight, Clearance & Rigging Diagram -3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: Al Qty: 1 Tag(s): RTU-1 CLEARANCE FROM TOP OF UNIT 72" CLEARANCE 36" CLEARANCE 48" 00 1411 iiiiii RETURN O, DOWNFLOW CLEARANCE 36" HORIZONTAL CLEARANCE 18" CLEARANCE 36" PACKAGED GAS/ELECTRIC CLEARANCE ROOF OPENING I I UNIT OUTLINE I 46" 53 1/4" I I 46" 88 5/8" PACKAGED GAS/ELECTRIC DOWNFLOW TYPICAL ROOF OPENING FLD=Furnished by Trane U.S. Inc.dba Trane/ Equipment Submittal Receiv ag of 21 Installed by Others i/0 5/2 017 10:2 7:5 3 AM Louis Vuitton Aspen April 14,2017 Accessory -3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: Al Qty: 1 Tag(s): RTU-1 <---- -----:------7------.4----------------7,„„ 1\ 1 �y ' ���i ` ECONOMIZER HOOD BAROMETRIC RELIEF HOOD BAROMETRIC RELIEF HOOD 1-Al 111 7 3/4" `,- 12" -- ACCESSORY-BAROMETRIC RELIEF DAMPER HOOD FLD=Furnished by Trane U.S. Inc.dba Trane/ Equipment Submittal ReceivegcL2, Installed by Others i/0 5/2 017 10:2 7:5 3 AM Louis Vuitton Aspen April 14,2017 Accessory -3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: Al Qty: 1 Tag(s): RTU-1 /llGi�.ze ..��1 of \rr 11111111111111111N1 ' ECONOMIZER HOOD Mao I II I iiik, ECONOMIZER HOOD 0 00 00 16 3/4" ACCESSORY-ECONOMIZER HOOD FLD=Furnished by Trane U.S.Inc.dba Trane/ Equipment Submittal Ie c e i vag of 21 Installed by Others i/05/2017 10:27:53 AM Louis Vuitton Aspen April 14,2017 Accessory -3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: Al Qty: 1 Tag(s): RTU-1 5/16" I l IHNHH9M6 6.863 2 7/8" r1 1/16" 1/8" - - f f 4 3/4" 3 3/8" L iI I (( 1/4" 000 rEll U1�i 9/16"®� �1 8 �1 1 3/8" - -S1 TEST t.INIR'''C=@)04°5 2 5/8" ZONE SENSOR-BAYSENS119 PROGRAMMABLE SENSOR FLD=Furnished by Trane U.S.Inc.dba Trane/ Equipment Submittal ReceivegcQf2, Installed by Others i/05/2017 10:27:53 AM Louis Vuitton Aspen April 14,2017 Accessory -3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: Al Qty: 1 Tag(s): RTU-1 2 7/8" 2 11/16" *UP 31/8" 411/16" 4 9/16" 0 0 n v IIIIIJI 1/4" v I I NOTES: 1.SEE ENGINEERING SPECIFICATION FOR DETAILS. 2.VERIFY ALL DIMENSION WITH INSTALLER DOCUMENTS BEFORE INSTALLATION. BAYCO2K001 B-WALL MOUNT CO2 ACCESSORY FLD=Furnished by Trane U.S. Inc.dba Trane/ Equipment Submittal ReceivegcL2, Installed by Others i/0 5/2 017 10:2 7:5 3 AM Louis Vuitton Aspen April 14,2017 Field Wiring - 3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: Al Qty: 1 Tag(s): RTU-1 DUAL SETPOINT MANUAL/AUTO CHANGE OVER PROGRAMMABLE WITH INDICATOR LIGHTS OCCUPIED/UNOCCUPIED PROGRAMS BAYSENS019/119 ZONE SENSOR 1))101\lI 7 8 9 10 11 12 14 ID o o 101/11l 12 14 �5,52 runt FACTORY TB1 AUXILIARY RELAY RTRM(J6) SWITCH SETTING SEE NOTE M3 14 -14 12 -12 1 OFF 2 ON 11 -11 J/ 3 OFF 10 -10_/ 4 OFF 9 - 9 / 5 OFF 8 - 8 J/ 6 OFF 7 - 7- 7 ON 6 OFF 5 4 9 OFF 3 2 1 I J • • C • • • • 0 ZONE SENSOR WIRE TABLE WIRE SIZE MAXIMUM WIRE LENGTH 22 GAUGE 1800" 20 GAUGE 3000" 18 GAUGE 4500" 16 GAUGE 7200" 14 GAUGE 11700" NOTE: 1.All wiring and devices shown dashed to be supplied and installed by the customer in accordance with national and local electrical codes. 2.Low voltage control wiring must not be run in conduit with power wiring. FLD=Furnished by Trane U.S.Inc.dba Trane/ Equipment Submittal Ie c e i vag of 21 Installed by Others i/05/2017 10:27:53 AM Louis Vuitton Aspen April 14,2017 Field Wiring - 3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: Al Qty: 1 Tag(s): RTU-1 3.75" CO2 SENSOR WIRING CO2 LTB LTB SENSOR © 100EE(RED) O ECA DCV 6P8 7 C 24V(+-) 24VAC 24VAC 150A(BLK) U 00 + 1 1 rl 13 C OUT CO2+ d — 2 2 151A(BRN) W44(BLU) C F CO2- 101W(BLU) \ C GND ALPHA 5430/2 CABLE 24COM VENTILATION OVERRIDE WIRING RTOM 5J6 FIRE PANEL LTB 195A(BLK) EXHAUST 1 m 3.50" EXH PURGE 2 194A(BLK) REF DESCRIPTION ECA ECONOMIZER ACTUATOR PUR 191A(BLK) I F FAN CONTACTOR PRESSURIZE 3 9 C PRS LTB LOW VOLT TERM BLOCK OC RTOM OPTIONS MODULE 24VAC WN1 WIRE NUT WN2 WIRE NUT W42(RED) �1 1R(RED) O L1 T1 NOTE: OPTIONAL POWER EXHAUST ACCY WIRES 1. DASHED LINES REPRESENT RECOMMENDED FIELD WIRING. WNF 2. APPLIES TO DUCT MOUNTED SENSOR ONLY. W43(BLU) 2 2K(BLU) O I 1—°— / L2— — T2 NOTES: 1.PRINT ON STRIP-TAC PLUS WITH BLACK LETTERS 2.REDUCE TRIMMED LABEL TO SIZE INDICATED. FLD=Furnished by Trane U.S.Inc.dba Trane/ Equipment Submittal ReceivegcL2, Installed by Others i/05/2017 10:27:53 AM Louis Vuitton Aspen April 14,2017 Field Installed Options - Part/Order Number Summary This is a report to help you locate field installed options that arrive at the jobsite. This report provides part or order numbers for each field installed option, and references it to a specific product tag. It is NOT intended as a bill of material for the job. Product Family -3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item Tag(s) Qty Description Model Number Al RTU-1 1 3-10 Ton R410A PKGD Unitary Gas/Electric YSC120F3RZA--D6B1A1A000C Field Installed Option Description _Part/Ordering Number CO2 wall mounted, field sensor kit BAYCO2K101A Programmable zone sensor BAYSENS119A FLD=Furnished by Trane U.S. Inc.dba Trane/ Equipment Submittal Receivel gof 21 Installed by Others i/0 5/2 017 10:2 7:5 3 AM