Loading...
HomeMy WebLinkAboutFile Documents.121 S Galena St.0083.2018 (16).ACBK troll , i iik. l',. 1...._ , _ ,. ,,,,, ili .„ _ ,z_ i TrendWall Product Specifications REVISION DATE 7/9/2014 RECEIVED 08/16/2018 ASPEN BUILDING DEPARTMENT PART 1 - GENERAL 1.01 SECTION INCLUDES This specification defines the TrendWall floor-to-ceiling panel system, which is designed to provide enclosed office spaces in an open plan environment and the ability to modify or reconfigure the office space to meet changing office requirements. The system consists of connecting structural panels with provisions for mounting furniture systems components and is fully integrateable and compatible with open plan office systems. 1.02 REFERENCES A. ANSI/BIFMA x 5.6— 1986: Mechanical Strength B. ASTM E84: Surface Burning Characteristics of Building Materials C. ASTM E90-90 /ASTM E413-04: Acoustical Sound Transmission Class D. FCNE 87-445D: GSA (General Services Administration) General Specification for Demountable Wall Systems E. International Organization for Standardization (ISO) F. National Fire Prevention Association (NFPA) G. BIFMA E3 Sustainability Standard 1.03 SYSTEM DESCRIPTION A. The system shall be for interior wall applications, fully relocatable and non- progressive. The system shall consist of three main components: 1. Panels: Panels shall be fully assembled and shall include the following sub- types: a. Solid b. Glazed c. Filler *All panel types shall be offered with both vinyl and fabric surface materials 2. Doors Sections: a. Doors shall be available as a pre-hung option within the system's Door Sections. b. Door Section options shall include both single and double hinged doors, at least one type of Sliding Door, and a Bi-Fold Door option. c. Doors Sections shall also be available less doors and/or hardware to accommodate building specific components. d. Door slabs shall be available in flush, window light and full light styles. Other styles may also be available. 3. The system's six other basic components shall be: RECEIVED -2- 7/11/209 /16/2018 ASPEN BUILDING DEPARTMENT a. Pilasters—A 2" 2.75" minimum vertical raceway must be available at every panel joint b. Ceiling Crown —The system shall interface with the building ceiling via a 2.5" tall Ceiling Crown that provides lateral stability c. Floor Plate—The plate that lays on the finished floor and locates the panels d. Connectors—The panel connectors that allow for in-line, corner, away and 4-Way panel conditions e. Base Trim —A 4" extrusion used to trim out the base raceway f. Electrical —A modular electrical system that fully integrates into the systems vertical and horizontal raceways. B. Design and Performance Requirements: 1. Fire Protection - The system's solid panel component shall meet fire protection requirements defined by NFPA 101 Life Safety Code - Class A, GSA, 3 2. Load Bearing - The system's solid panel unit shall meet ANSI/BIFMA mechanical strength load tests. 3. Acoustics - The system's solid panel unit shall produce a minimum sound transmission class (STC) of 40 +1-2 per ASTM E90-04/ E413-04 4. Sustainability a. The system shall be certified IevelTM I per BIFMA E3 Sustainability standard b. The system shall be Indoor Air Quality Certified to SCS-EC10.2-2007 1.04 SUBMITTALS A. Upon receipt of customer's floor plan and completed TrendWall Request for Quotation (RFQ) Form, Trendway shall create a computer-generated (CAD) floor plan of the desired TrendWall office for customer's approval. B. Upon approval of the TrendWall CAD drawing and submission of a corresponding purchase order, the product shall be built to the exact approved specifications of the customer. 1.05 QUALITY ASSURANCE A. The specified TrendWall panel system shall be designed, developed, manufactured, inspected, tested, installed and serviced in accordance with ISO9001 Standards and the manufacturer shall be a registered ISO company. B. Independent laboratory certification shall be available which certify that the standard solid TrendWall panels provide an STC rating of 41 in accordance with ASTM E90-04 and E413-04. RECEIVED -3 - 7/11/209 /16/2018 ASPEN BUILDING DEPARTMENT C. Independent laboratory certification shall be available which certify that the standard TrendWall fabric and vinyl covered panels meet the class A requirements of the NFPA 101 Life Safety Code with a flame spread maximum allowable of 25 and maximum smoke density allowable of 450. D. Certification shall be available which verify that standard solid TrendWall fabric and vinyl covered panels meet GSA flame spread maximum requirements of 25 and smoke density maximum allowable of 50 per ASTM E84. E. Independent laboratory certification shall be available which certify that standard solid TrendWall panels meet load bearing capacity for hanging components of not less than 7 pounds per lineal inch when tested in accordance with ANSI/BIFMA x 5.6-1986. 1.06 DELIVERY, STORAGE AND HANDLING A. Packing, Shipping, Handling, and Unloading: 1. TrendWall products shall be packaged in the Trendway factory by the best means as determined by Trendway's packaging engineer. 2. All orders shipped to any destination within the contiguous United States, shall be F.O.B. origin, freight prepaid, and risk of loss or damage shall pass to Buyer upon delivery to carrier. Trendway shall determine the method and agency of transportation to be used. 3. Customer-directed or expedited shipments (Air Freight, Federal Express, etc.) shall be prepaid and billed at actual cost. 4. An "Order" is defined as each purchase order issued with a single "shipped to" address without special marking or tagging. B. Acceptance at Site: 1. In the event that special F.O.B. destination terms are agreed to by Trendway or delivery is made on Trendway owned or leased carriers, the customer or authorized representative is responsible for noting any freight damage or shortage on the freight bill of lading at time of delivery and must notify Trendway within five (5) days of delivery day of any such damage or shortage. 2. Assistance in a concealed damage claim on an F.O.B. destination shipment will be provided by Trendway only if the product has been immediately unpacked and both the carrier and Trendway have been promptly notified of resultant damage so the proper inspection can be made. C. Storage and Protection: 1. When the buyer delays shipment, Trendway reserves the right to place the goods in storage at customer's risk and cost. RECEIVED -4- 7/11/20 /16/2018 ASPEN BUILDING DEPARTMENT 2. All terms and conditions of the sale including but not limited to invoicing and payment, will continue as if the product had been shipped to a Buyer specified destination; except that title remains with Trendway and that Trendway reserves the right to modify payment terms to assure recovery of any additional cost incurred. 1.07 PROJECT/SITE CONDITIONS A. Environmental Requirements and Existing Conditions: 1. The installation site shall be clear and ready for TrendWall installation 2. Finished floor shall be completely installed and ready for traffic prior to beginning TrendWall installation 3. Finished Ceiling: a. If attaching to a Drywall ceiling / soffit, the surface must be completely prepped and finished. b. If attaching to a drop ceiling, the structural grid must be completed prior to the installation of the TrendWall crown. 1.08 SEQUENCING AND SCHEDULING For Installation Sequencing and Scheduling, refer to the Trendway Installation Guide for TrendWall Floor-To-Ceiling Panels or contact Trendway Customer Service. 1.09 WARRANTY For complete Warranty description, contact Trendway Customer Service. 1.10 MAINTENANCE For proper maintenance of Trendway products, contact Trendway Customer Service for appropriate literature and/or instructions. RECEIVED _5 _ 7/11/2� "16/2 018 ASPEN BUILDING DEPARTMENT PART 2 - PRODUCT 2.01 MANUFACTURER Trendway Corporation 13467 Quincy Street Holland, MI, 49424 616.399.3900 2.02 MATERIALS A. Solid Panels shall be made from the following materials: 1. Side /Top / Bottom and Cross rails of powder coated, roll formed steel 2. Removable skins comprised of 3/8" gypsum wallboard faced with commercial grade wall covering. 3. Sound Batting of 4.0 pcf mineral wool B. Glass Panels contain the following materials: 1. Side /Top / Bottom / Cross and Glass rails of powder coated, roll formed steel 2. Removable skins comprised of 3/8" gypsum wallboard faced with commercial grade wall covering. 3. Sound Batting of 4.0 pcf mineral wool 4. Glass retaining moldings of extruded PVC C. Door Sections shall be made from the following materials: 1. Side /Top / Bottom and Cross rails of powder coated, roll formed steel 2. Removable skins comprised of 3/8" gypsum wallboard faced with commercial grade wall covering. 3. Sound Batting of 4.0 pcf mineral wool 4. Pre-machined Door Jambs of powder coated, roll formed steel 5. Door Slabs: a. Hollow Core Doors contain: i Finger Jointed Pine stiles and rails ii Honeycomb interior iii MDF skins laminated in either vinyl of HPL b. Solid Core Doors contain: i Finger Jointed Pine stiles and rails RECEIVED _6_ 7/11/2� /16/2018 ASPEN BUILDING DEPARTMENT ii LDF solid core interior iii MDF skins laminated in either vinyl of HPL 6. Ceiling crowns shall be 18-gauge roll-formed steel 7. Floor plates shall be 20-gauge roll-formed steel 8. Panel connectors shall be 11-gauge steel 9. Pilaster Covers shall be finished strips of 22-gauge rolled-formed steel and/or .06 thick rigid PVC with snap in place design, in fabric or vinyl coverings 10. Vinyl base trim shall be of extruded PVC, to match the system's trim colors. D. Filler Panels shall be made from the following materials: 1. Side rails of powder coated, roll formed steel 2. 8 pcf Styrofoam core 3. Laminated skins comprised of 3/8" gypsum wallboard faced with commercial grade wall covering 2.04 FINISHES A. All metal surfaces shall be powdered coated in one of 18 Trendway standard trim colors. Reference Trendway's Surface Material Guide for details B. All PVC trim pieces shall be extruded to match any of the Trendway standard smooth trim colors. Reference Trendway's Surface Material Guide for details. C. Panel skins shall be offered in a variety of commercial grade wall coverings, including both vinyl and fabric materials. Reference Trendway's Surface Material Guide for details RECEIVED -7- 7/11/20 "16/2018 ASPEN BUILDING DEPARTMENT PART 3 - EXECUTION 3.01 EXAMINATION/INSPECTION A. Before installing the TrendWall panel system, a re-inspection of the installation site shall be made by the contractor to re-verify vital information used to specify the initial product required, such as ceiling height, floor conditions, and other physical characteristics that can affect an installation. 3.02 INSTALLATION A. Five basic steps comprise the TrendWall installation process: 1. Ceiling Crown 2. Floor Plate 3. Panels 4. Glazing and Electrical 5. Trim B. For a detailed description of each process step, refer the Trendwall Planning & Specification Guide or contact Customer Service. 3.03 Supplemental information on the following subject areas are also available through Trendway Customer Service. A. REPAIR/RESTORATION B. RE-INSTALLATION C.ADJUSTING D. CLEANING For additional specifications and technical information, contact your local Trendway representative or Trendway Customer Service. RECEIVED -8- 7/11/20 /16/2018 ASPEN BUILDING DEPARTMENT